AIR CONDITIONER 2 3 1

image

Contents

1. Left rear side refrigerant pipe hole 7 6 qt 150 or more to ceiling T 120 or more to wall Right rear side refrigerant pipe hete Et A holes in the wall Insert Clip anchor for appropriate mounting screws 3 Fit the installation plate on the wall with five or eight type A screws NOTE Fit the Installation Plate and drill holes in the wall according to the 120 or more wall structure and corresponding to wall mounting points on the installation plate The installation plate provided with the machine differ from appliance to appliance Dimensions are in mpm unless otherwise stated 2 Left rear side refrigerant Correct orientation of Installation Plate Model A A 710 B 250 C 100 D 110 Model B A 790 B 265 C 100 D 150 150 or more to ceiling 120 or more i to wall i I Right rear side refrigeran rieg t 150mm or more from the ceiling Hooked Part Hw 120mm or morel from the wi 8 etermine hole positions according to left and right 8 Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock A CAUTION side of the installation plate The hole center is obtained by measuring the distance as shown
2. connective cable after installation Air freshening filter used to install on the Air filter for some models only 1 Except the above parts provided the other parts needed during installation you must purchase metal plate or the like Drainage 1 Run the drain hose sloping downward Do not install the drain hose as illustrated in Figures 2 When connecting extension drain hose insulate the connecting part of extension drain hose with a shield pipe do not let the drain hose slack Connective pipe installation 1 For the left hand and right hand piping remove the pipe cover from the side panel 2 For the rear right hand and rear left hand piping install the piping as shown 3 Bundle the tubing connecting cable and drain hose with tape securely evenly as shown in Figure on the right Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room Do not put anything else in the box CAUTION Connect the indoor unit first then the outdoor unit Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack Heat insulated both of the auxiliary piping Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Never intercross nor intertwist the power wire with any other wiring Run the drain hose slopp
3. check ppi Perform test operation after completing gas leak check at the flare nut connections and electrical safety check e Check that all tubing and wiring have been pi e Check that the gas and liquid side service va roperly connected Ives are fully open 1 Connect the power press the ON OFF button on the remote controller to turn the unit on 2 Use the MODE button to select COOL HEAT AUTO and FAN to check if all the functions works well 3 When the ambient temperature is too low lower than 170C the unit cannot be controlled by the remote controller to run at cooling mode manual operation can be taken Manual operation is used only when the remote controller is disable or maintenance necessary Hold the panel sides and lift the panel up to an angle until it remains fixed with a clicking sound Press the Manual control button to select the AUTO or COOL the unit will operate under Forced e AUTO or COOL mode see User Manual for details 4 The test operation should last about 30 minutes Manual control b AO AUTO COOL utton
4. in the diagram above 2 Dirll the piping plate hole with 2165mm hole core drill 3 Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side 4 Always use wall hole conduit when drilling metal grid Indoor 1 This equipment must be earthed and installed with earth leakage current breaker It may cause electrical shock if grounding is not perfect Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause fire Carry out drainage piping as mentioned in installation instructions If drainage is not perfect water may enter the room and damage the furniture SELECT THE BEST LOCATION Indoor unit There should not be any heat source or stream Asemorriare near the unit There should not be any obstacles blocking the air circulation em orm A place where air circulation in the room is good 7 A palce where drainage can be easily done A palce where noise prevention is taken into consideration Do not install the unit near the door way Ensure the spaces indicated by arrows from the wall ceiling fence or other obstacles There should not be any direct sunlight If unavoidable sunlight prevention should be taken into consideration 2 3m or more Outdoor unit If an awning is built over the unit to prevent direct sunsight or rain be careful that heat r
5. 202000192534 CS211I BP9A1U HL 20140722 INSTALLATION MANUAL FOR ROOM AIR CONDITIONER Split Wall Mounted Type SAFETY PRECAUTIONS Please read this installation manual completely before installing the product If the power cord is damaged replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring Standards by authorised personnel only Contact an authorised service technician for repair maintenance or installation of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance All the pictures in the instructions are for explanation purposes only The actual shape should prevail The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details a The seriousness is classified by the following indications warning tis symbol indicates the possibility of death or serious injury A CAUTION This symbol indicates the possibility of injury or damage to property A WARNING leakage electrical shock or fire 2 Use the attached
6. NOTE SPE 9 The wire size of power supply cord and of appliance area interconnected wire and the current of A mm2 the fuse or switch are determined by the gt 3 and A 075 maximum current indicated on the gt 6 and 2 14 1 nameplate which located on the side panel gt 10 and 1 15 of the unit Please refer to the nameplate gt 16 and 22 25 before selecting the wire size fuse or switch The controller of the air conditioner designed gt 25 and 13 4 with a fuse protection function under gt 32 and 24 6 abnormal conditions the specifications of the fuse have printed on the circuit board such as T3 15A 250VAC T5A 250VAC etc Connect the cable to the indoor unit NOTE Before performing any electrical work turn off the main power to the system 1 The inside and outside connecting cable can be connected without removing the front grille 2 The indoor power cord type is HOSVV F or HO5V2V2 F the outdoor power cord and interconnected cord type is HO7RN F 3 Lift the indoor unit panel up remove the electrical box cover by loosening the screw 4 Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s respectively 5 Wrap those cables not connected with terminals with insulation tapes so that they will not touch any electrical components Secure the cable onto the control board with the cord clamp on Yl ao NOTE If used as MONO unit for the standby con
7. accessories parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock or fire 3 Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop and cause injury 4 For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or 5 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted er theterminatiteonrectios orfadngis aet perfect 6 Wiring routing must be properly arranged so that control board cover is fixed properly If control board 7 When carrying out piping connection take care not to let air substances other than the specified refrigerant go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury Fit the Installation Plate w FIT THE INSTALLATION PLATE The mounting wall is strong and solid enough to prevent it from the vibration Indoor unit outline 120 or more 1 Fit the installation plate horizontally to wall on structural parts of the wall with spaces around the installation plate 2 If the wall is made of brick concrete or the like drill five or eight 5mm diameter
8. adiation from the condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrow from wall ceiling fence or other obstacles Do not place any obstacles which may cause a short circuit of the discharged air Settlement of outdoor unit Anchor the outdoor unit with a bolt and nut 2 10 or MO TighTenoutstodramilyoorparohasetaay gitkeone of the following Install the outdoor unit according to the dimension as indicated in the table below Outdoor unit dimension Mounting dimensions mm WxHxD A mm B mm 760x590x285 530 290 810x558x310 549 325 780x540x250 549 276 845x700x320 560 335 J4 ZC ZO00Z Number Name of Accessories Installation Plate Clip Anchor 8 depending on models Self tapping Screw A ST3 9x25 5 8 depending on models Seal For cooling amp heating models only 1 Drain Joint For cooling amp heating models only 1 216 3 Connecting Liquid side 119 5 Parts you must purchase The pipe pipe size differ from appliance to appliance Assembly Judy Consult the technician for the proper Gas side 2112 size 116 Remote controller 1 Self tapping Screw B ST2 9x10 2 optional Remote controller holder parts 1 Optional part Magnetic ring used to put it around the one piece one cable
9. ed downward to drain out the condensed water smoothly Indoor unit installation 1 Pass the piping through the hole in the wall 2 Hook the indoor unit onto the upper portion of installation plate Engage the indoor unit with the upper edge of the installation plate Ensure the hooks are properly seated on the installation plate by moving it in left and right 3 Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping 4 Press the lower left and right side of the unit against the installation plate until hooks engages with the their slots A Do not put the end of drain hose into water Do not block water flow by a rise Move and tape the drain hose with piping in a position as mentioned in Fig Below Cover for the right piping Cover for piping Pipe holder Pipe cover Left piping Pipe cover Left back piping Right piping Right back piping Indoor unit Ponding box Connective Pipe room Lb L Connective pipe Wrapping belt Drain hose Upper Hook Cushioning material Lower Hook CONNECT THE CABLE TO THE INDOOR UNIT Electrical work Electric safety regulations for the initial Installation 1 If there is serious safety problem about the power supply the technicians should refuse to install the air conditioner and explain to the client until
10. in joint is slightly different according to the different outdoor unit For the drain joint with the seal Fig A first fit the seal onto the drain joint then insert the drain joint into the base pan hole of outdoor unit rotate 90 amp to securely assemble them To install drain joint as shown in Fig B insert the drain joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound Connecting the drain joint with an extension drain hose Locally purchased in case of the water draining off the outdoor unit during the heating mode Aoonuodco Seal cas joint a Ye 1 Cut a pipe with a pipe cutter 2 Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal and flare the pipe 3 Firmly hold copper pipe in a die in the dimension shown in the table below Outer diam A mm mm Max Min 6 35 1 3 0 7 9 52 1 6 1 0 12 7 1 8 1 0 16 2 2 2 0 Copper pipe Clamp hale SF Rae Vig indoit tubing Mu Pipings r Outer diam 2l6 35mm Tightening Tightening connection Align pipes to be connected Sufficiently tighten the flare nut with fingers and then tighten it with a spanner and torque m wrench as shown Excessive torque can break nut depending on installation conditions P o 52m R 12 7mm 216mm A
11. l CONNECT THE CABLE TO THE OUTDOOR UNIT Remove the electrical control board cover from the outdoor unit by loosening the screw 2 Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and 3 Secure the cable onto the control board with the cord clamp outdoor units 4 To prevent the ingress of water form a loop of the connective cable as illustrated in the installation diagram of indoor and outdo or units 5 Insulate unused cords conductors with PVC tape Process them so they do not touch any electrical or metal parts Terminal block of outdoor unit o o bil To indoor unit Power supply Model A o S EN To indoor unit m AIR PURGING AND TEST OPERATION NOTE Power supply Model B Connective pipe length will affect the capacity and energy efficiency of the unit The nominal efficiency is tested basing on the pipe length of 5 meters 1 Air purging Air and moisture in the refrigerant system have undesirable effects Therefore the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensables and moisture from the system m Check that each tube both liquid and gas side tubes between the indoor and outdoor u
12. nits have been properly connected and all wiring for the test run has been completed Pipe length and refrigerant amount Connective pipe length Air purging method Additional amount of refrigerant to be charged Less than 5m Use vacuum pump Liquid side 6 35m R22 Pipe length 5 x3 More than 5m Use vacuum pump R410A Pipe length 5 x15g m m Liquid side 2 9 52mm R22 Pipe length 5 x60g m R410A Pipe length 5 x30g m Og m For the R407C refrigerant model make sure the refrigerant added into air conditioner is liquid form in any cases When relocate the unit to another place using vacuum pump to perform evacuation CAUTION Open the valve stem until it hits against the stopper Do not try to open it further Securely tighten the valve stem cap with Outdoor Refrigerant Indoor i m a spanner or the like Gas side all Liquid side n Valve stem cap tightening torque See Tightening torque table 7B 2 When using the Vacuum Pump 1 Completely tighten the flare nuts A B C D connect the manifold valve charge hose to a charge port of the packed valve on the gas pipe side 2 Connect the charge hose connection to the vacuum pump 3 Fully open the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare nut of the packed valve on the gas pipe side and check tha
13. t the air is entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus 5 After the evacuation is complete fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump Make evacuation for 15 minutes and more and check that the compound meter indicates 76cmHg 1 0x105Pa 6 Turn the stem of the packed valve B about 450 counter clockwise for 6 7 seconds after the gas coming out then tighten the flare nut again Make sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve 3 Safety and leakage check 1 Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connections and outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping If bubbles come out it indicates that the pipes have leakage 2 Leak detector Use the leak detector to check for le CAUTION A Lo packed valy Hi packed valve C and D are ends of indoor unit connection 4 Test running Packed valve x Half union Manifold valve Compound meter 76cmHg Pressure gauge QO Handle LA Charge hose Y Handle Hi Be rarge hose vum pump Packed valve Indoor uni check Outdoor
14. the problem is solved 2 Power voltage should be in the range of 90 110 of rated voltage 3 The surge protector and main power switch with a 1 5 times capacity of Max Current of the unit should be installed in power circuit Ensure the air conditioner is grounded well 4 The appliance shall be installed in accordance with national wiring regulations Do not operate your air conditioner in a wet room such as a bathroom or laundry room 5 An all pole disconnection device which has at least 3mm clearances in all poles and have a leakage current that may exceed 10mA the residual current device RCD having a rated residual operating current not exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 6 For the unit adopts auxiliary electric heater keep at least 1 meter away from the nearest combustible materials 7 According to the attached Electrical Connection Diagram located on the panel of the indoor amp outdoor unit to connect the wire All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians 8 An individual branch circuit and single receptacle used only for this air conditioner must be available See the following table for suggested wire sizes and fuse specifications Minimum cross sectional area of conductors Rated current Nominal cross sectional
15. trol needs the cross section area of cable connected to L 1 1 1 L 2 N must be sufficient for the maximum system current The maximum system current is equal to the sum of indoor unit and outdoor unit rated current Terminal block of indoor unit Front Panel YeS6 III 6S Electrical box wt w ss a Se _ S amam _ aua To outdoor unit Model B To outdoor unit Model A al OUTDOOR INSALLATION PRECAUTION stall the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where the discharged air is not blocked In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates e Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wall should be solid brick concrete or the same intensity construction or actions to reinforce damping supporting should be taken The connection between bracket and wall bracket and the air conditioner should be firm stable and reliable Be sure there is no obstacle which block radiating air Incorrect Correct Barrier Stro i ng wind 5 he dra