Home

RealScan-G1 User Manual

image

Contents

1. b Double click Performance and Maintenance Pick a category Control Pane Steh to Classic wiew See Also 2J Ap Windows Update 3 o Help and Support Network and Internet Connections ey WE Accounts e wr 2 os Appearance and Themes 28 Printers and Other Hardware lt ay Add or Remove Programs Date Time Language and Regional i s Sounds Speech and Audio Devices Accessibility Options 7 Performance and Maintenance Security Center c Double click System Pick a task f ry See basic information about your computer gt Adjust visual effects free up space on your hard disk gt Baek up your data 3 Rearrange items an your hard disk to make programs run faster or pick a Control Panel icon PT Administrative Toots a Power Options A Wir Scheduled Tasks a System System Properties Generel Computer Nome ff Hardware Advanced d Select menus as shown to the left Device Manager The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Driver Signing lets you make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Hardware Profiles Hardware poles provide a way for you to set up and siere e Select Device Manager Universal Serial Bus different hardware configurations Controller and check wh
2. RealScan Gi n Repeated actions When checked the same action selected would be repeated Displays the scanned fingerprints Original image or quality image 3 Displays each fingerprint from the original image scanned in area 4 above 5 Indicates fingers to be scanned It can be changed by pressing Prev or Next button 6 Scanned fingerprints are scored and results of the scanned fingerprints are displayed 7 Capture and Stop buttons for scanning fingerprints Save button to save scanned Copyright 2012 Suprema Inc On the web www supremainc com 1 0 4 Using Software 4 2 Basic Functions Display Option Normal Fingerprint Check Fingerprint Quality Normal Original Image Displays the original fingerprint Quality check Quality Image Displays the quality of the scanned fingerprint Lighter areas indicate higher quality Indicate Indicates the finger to be scanned Prev or Next button can be used to change scanning order X Prev and Next buttons do not work during the preview Orem On Fingerprint Scanning Order Quality Information Quality Information NFIQ Displays NFIQ results for image quality NIQ f Io Result Message Displays information after scan is Result Message completed Status Displays scanning progress Status Oo Fingerprint Information and Message window Copyright 2012 Suprema
3. again b If the device still isn t detected the PC may not properly recognize the USB Reboot the PC and check Device Manager If Suprema RealScan G1 is detected but still does not function do the following End the program and unplug the USB cable Plug the USB cable after five seconds and restart the program X If the device does not function even after the above contact the Customer Support Center Copyright 2012 Suprema Inc On the web www supremainc com 1 f Suprema Inc Address Park View Office Tower 16F Jeongja dong Bundang gu Gyeonggi do South Korea TEL 82 31 710 4502 Fax 82 31 783 4503 Online Customer Support sales supremainc com Website www supremainc com Copyright 2012 Suprema Inc On the web www supremainc com 18
4. Inc On the web www supremainc com 11 4 Using Software Button 2 l Capture G4 Sto Auto Mode t p 4 P Save aaa Result m stor F ry Result 1 Capture button Used to preview or start scanning a Manual Capture button changes into Scan and preview is provided As shown on the right side the Scan button is changed into Capture after Scan button is pressed By pressing Capture button scanning will be started b Auto Capture button is activated as shown above Scanning will be started by pressing Capture button 2 Stop button Stops scanning the fingerprint during the preview 3 Save button Saves the scanned image as a file 4 Result button Shows the scanned image with the related data 4 3 Scanning Fingerprints Individually Scanning Right Thumb Finger 6c Om Ome Single Flat Scanning Screen Single Flat Scan Select 1 Finger Flat in the Action menu Select a finger to scan using the Prev and Next buttons at the upper right of the screen 3 If the Scan button is pressed at the lower right of the screen the button changes into Capture and then the preview image is shown Place the finger on the scanning area and press Capture Copyright 2012 Suprema Inc On the web www supremainc com 12 4 Using Software 4 4 Notes o
5. RealScan Gl User Manual e BAE tec 02 1 1 General Information 02 TAZ COMIC aie tessa Sea sa ch ones ae eee eo See ene eS ee aet ese ne Seen eee See eeeeeces 02 T Safety NO teS 223 5 ssseeceneeese eae sass eG ieee eee Seat a eee ease eee eae eheseeoee 02 t4 DEV Ce Pal 6 esas oan eee ae Ee 03 BM ae gO ra 04 2 12 NOD ViGW sane eee 04 22 Rear NiG Weessse ese o eee ee eee eee ete 04 2 3 DEVICE Lapal ses eerie hese et eteere 05 24 Device Exton en E 05 2 5 2 06 e E eI a a 07 3 1 Minimum PC Requirements 07 3 2 Device Driver Installation 08 e AUO ONA eea eee eee ae 10 Am Initial SCKe Clas ee eet 10 4 2 Basic FUNCIONS 2336s sss east Se eo esee 11 4 3 Scanning Fingerprints Individually 12 4 4 Notes on Fingerprint Scanning 13 gt atrada and ManaQenien lt 3 lt esesee sees 14 5 1 Prism Maintenance 14 Ce O I A 15 L Omer UD ON eene a aeiaai 18 Copyright 2012 Suprema Inc On the web www supremainc com 1 1 Basic Specifications 1 1 General Information Scans single flat fingerprint images High quality image scanning regard
6. UT POWER 5V 500mA via USB Port Interface USB 2 0 High Speed Model RS G1 T Device Label Includes interface power specifications certification markings and device number 2 4 Device Exterior 55mm 44 5mm 106 5mm Device Dimensions 106 5mm L 55mm W 44 5mm H Device Weight 0 18Kg including cable Copyright 2012 Suprema Inc On the web www supremainc com io USB A Type 1 800mm USB Cable A type USB cable connected to the device through stopper with 1 800mm cable Copyright 2012 Suprema Inc On the web www supremainc com 6 3 1 Minimum PC Requirements oe Support USB2 0 High Speed Windows XP or higher Copyright 2012 Suprema Inc On the web www supremainc com f 3 Installation 3 2 Device Driver Installation Windows XP VISTA 7 RealScan_Driver s86 InstallShield Wizard Welcome to the InstallShield Wizard for RealScan_Driver x86 The InstallShield Wizard will install RealScan_Oriver xe6 on your computer To continue click Nest Cancel Driver Installation 1 Disconnect the device s USB cable to a PC before program installation Click Next if the above screen appears after running RealScan_Driver x86 V1 2 0 0 exe X When using 64 bit OS use RealScan_Driver x64 V1 2 0 0 exe for driver installation RealScan_Driver s86 InstallShield Wizard Setup Status The InstallShield Wizard ts instal
7. ether cea a Suprema RealScan G1 is connected Copyright 2012 Suprema Inc On the web www supremainc com 15 Windows Vista Internet Internet Explorer ey E mail Windows Mail 4 Paint d Backup and Restore Center D gt R5 10 Demo suprema Documents Pictures Music Games Recent Items Computer Network Connect To Default Programs All Programs Help and Support ktort Search ZE 6 Troublesh ooting a Select Start Control Panel menus eee Gv al System and Maintenance Welcome Center Lie Suprema Windows Vista Ultimate Intel R Celeron R CPU 2 66GHz 1 00 GB RAM Standard VGA Graphics Adapter Computer Name SUPREMA PC 1 Get started with Windows 13 View computer details ep Connect to the Internet Show all 13 items a Transfer files and settings What s new in Windows Vista 2 Offers from Microsoft 7 Go online to find it fast with Windows Live Go online to learn about Aa Windows Live ay Sho Go online to connect and share with Windows Live Go online to Windows Marketplace 05 all 7 items P b Select System and Maintenance and double click Start Windows X 4 Search D Show more details c Double click View Computer Details Add new users Personalize Windows IRS Go online to help protect your PC with Windows Live Go online to find more ways to help protect
8. less of states of finger Automatically segments when scanning a flat Prevents external light halo effect and ghost images Blue LED indicator USB 2 0 transmits data and supplies power For use only with UL Listed I T E computer Input Power 5VDC 500mA 1 2 Certificate FCC Statement This device has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operated the equipment under FCC rules 1 3 Safety Notes Do not dismantle or alter this device Electric shock or damage may occur If the device was intentionally dismantled or altered by the user repair services will not be provided Do not use this device in places where flammable or explosive gas may be in the air A fire or explosion may occur If there i
9. ling RealScan_Driver 86 Registering product InstallShield Cancel Driver Installation 2 3 Device driver is being installed Copyright 2012 Suprema Inc On the web www supremainc com 8 InstallShreld Wizard Complete The InstallShield Wizard has successtully installed RealScan_Driver xob6 Click Finish to exit the wizard Driver Installation 3 Click Finish after driver installation Connect the device s USB cable to the PC and check the installation status in Device Manager X Refer to 6 Troubleshooting if installation is unsuccessful Copyright 2012 Suprema Inc On the web www supremainc com 9 4 Using Software 4 1 Initial Screen 2 8 4 NON ON RealScan Demo Program View Option Help Functional scan AFIS roll flat r Repeated actions Display Option V Segmentation Original image C Quality image Scan Option Auto C Manual RealScan Gi Demo H E 1 finger flat Initial Screen 1 finger Flat Scans single flats until you press Stop button 2 Display Option 4 Area where fingerprint was scanned in the message window 1 Fingerprint Scan Mode Only one scanning method is available image and Result button to check result fingerprint images 8 Scan Option Auto Mode Device automatically detects and saves fingerprint Manual Mode Capture proceeds in a manual manner
10. n Fingerprint Scanning Top Scanning Side Scanning Top Scanning If only the top of the finger is placed on the scanning area only the top of the finger part will be scanned as shown above Side Scanning If only the side of the finger is placed on the scanning area and the center of the finger does not touch the scanner only the side of the finger part will be scanned as shown above Blurred Image Good Fingerprint Image Blurred Image When applying too much pressure with one s finger to the scanning area the image may become blurred as shown above To scan a fingerprint successfully place the finger at the center of the scanning area with reasonable pressure Copyright 2012 Suprema Inc On the web www supremainc com is 5 1 Prism Maintenance Clean the prism using the soft cloth provided with the device If the prism is covered with foreign matter or is dirty due to repeated scanning clean the prism with the soft cloth Do not use any chemical agents such as wax benzene alcohol thinner perfume lubricant or cleansers If the soft cloth provided with the device is not available use cloth normally used for cleaning glasses Copyright 2012 Suprema Inc On the web www supremainc com 1 f Check whether the device is connected See below Windows XP a n a Select Start Control Panel pA a Y mn ae BME Ad computa aer ranr pograny nd oprah coum roe
11. s water or foreign matter inside the device USB cables and contact the customer support center Do not leave the device in an airtight place such as inside a vehicle and keep the device away from heat or direct sunlight The device s exterior or components may be affected Sharp changes in temperature can generate moisture within the device and can result in poor performance Idle period is recommended after substantial changes in temperature Copyright 2012 Suprema Inc On the web www supremainc com 2 1 4 Device Parts All About Fingerprints Device Case Software CD Optional Copyright 2012 Suprema Inc On the web www supremainc com 3 2 Exterior and Cable 2 1 Top View 1 1 Scanning Window Area for scanning user s fingerprints Blue LED indicator inside scanning window 2 2 Rear View 3 2 1 2 3 1 Device label showing basic information including serial number of the device 2 4 M3 taps for mounting external bracket 3 Rubber pads for anti slippage Copyright 2012 Suprema Inc On the web www supremainc com f 2 Exterior and Cable 2 3 Device Label Suprema Inc RealScan G1 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation INP
12. your PC gt E Run at startup Welcome Center can be found in Control Panel System and Maintenance gt Sytem and Maintenance System Gu Control Panel Tasks vs e View basic information about you Device Manager Windows edition Remote settings Windows Vista Ultimate System protection Advanced system setings Service Pack 1 Copynght 2007 Microsoft Conporation All rights reserved sro x orth p our computer d Select Device Manager e Select Device Manager Universal Serial Bus Controller and check whether Computer name domain and Computer name Full computer name Computer description Workgroup Windows activation Windows is activated 32132 00031 Product ID 89580 CEM 733 wis ER windows Expenence Index _ Suprema RealScan G1 is connected workgroup settings suprems PC W Change settings suprema PC WORKGROUP Ac ange product ke Copyright 2012 Suprema Inc On the web www supremainc com 6 Troubleshooting If Suprema RealScan G1 is not installed in Device Manager do the following Check whether the USB cable is connected a If a USB cable that was not provided with the device is being used use the USB cable that came with the device b Check that the USB connector is tightly plugged in If the device is connected to the PC a Unplug the USB cable from the PC wait five seconds and plug it in

Download Pdf Manuals

image

Related Search

Related Contents

Zweibrüder LED Lenser M7R  取扱説明書PDF - コメット電機株式会社  Avaya 7940 IP Phone User Manual  Bandschleifmaschine Ponceuse à bande  ソーラーランタンの作り方+取説  ELTRAL K30 ELTRAL K30 Synchro  Distribution Agreement In presenting this thesis  PLC/SCADA systems in automation control design for individual  User manual uniCFUGE 5 - Master Spanisch - LLG  