Home

Ametek Jofra CTC Series

image

Contents

1. Specification Sheet SS CP 2281 US Simplified calibration documentation JOFRACAL All CTC series calibrators are provided with the JOFRACAL cali bration software This software allows the user to customize his or her calibration routines The software is easy to use so you do not have to be a programmer to configure your own calibration procedures The software features prompts menus and help functions that guide you through the configuration process The JOFRACAL calibration software supports automatic calibration for all JOFRA dry block calibrators equipped with an RS232 serial data interface including the JOFRA DTIO50 digital thermometer the JOFRA DTI 1000 digital ther mometer and the JOFRA ASM Multi scanner For semi automatic calibrations the software also supports liquid baths ice points or other dry block heating and cooling sources Using the software s SCENAHRIO function allows for combining instruments in virtually any configuration Once all calibrations are completed the data may be uploaded to the JOFRACAL calibration software for post processing and printing of certificates The calibration data collected may be stored on the personal computer for later recall or analysis The JOFRACAL temperature calibration software may be donw loaded from our web page www jofra com Please also see more about JOFRACAL calibration software in specification sheet SS CP 2510 which can be found at www jofra com
2. temperature Temperature ranges CTC 140A 17 to 140 C 1 to 284 F CTC 320A 33 to 320 C 91 to 608 F CTC 320B 33 to 320 C 91 to 608 F CTC 650A 33 to 650 C 91 to 1202 F CTC 650B 33 to 650 C 91 to 1202 F CTC 1200 A 300 to 1205 C 572 to 2200 F Fast calibration is timesaving The specially designed heating block profile heats up to 320 C 608 F in just 4 minutes and to 650 C 1202 F in only 10 minutes High flexibility You are not limited by fixed holes Inter changeable insertion tubes are used to match the diameter of your sensor under test Enhanced stability MVI circuitry ensures stability despite mains supply variations in the process environment Timesaving features Fast one key one function access to the automatic switch test and auto stepping Documentation made easy RS232 communication and JOFRACAL calibration software are included in the standard delivery Complete marine program Part of a complete program of marine approved temperature pressure and signal calibrators including temperature sensors See more at www jofra com ISO 9001 Manufacturer Specification Sheet SS CP 2281 US JOF RA CTC series Compact Temperature Calibrators Fast timesaving and reliable true temperature calibrator A fast timesaving and reliable true temperature calibrator designed for on site use The CTC series is a fast dry block that offers both interchangeable inserts the MVI stabi
3. Calibration of up to 24 sensors with JOFRA ASM Using the JOFRA CTC series together with the ASM Advanced Signal Multi scanner offers a great time saving automatic solution to calibrate multiple temperature sensors at the same time The ASM series is an eight channel scanner controlled by JOF RACAL software on a PC Up to 3 ASM units can be stacked to calibrate up to 24 sensors at the same time It can handle sig nals from 2 3 and 4 wire RTD s TC s transmitters ther misters tempera ture switches and voltage Please also see more in specifica tion sheet SS CP 2360 which can be found at www jofra com STANDARD DELIVERY CTC dry block calibrator user specified Mains power cable user specified Traceable certificate temperature performance Insert user specified Tool for insertion tubes User manual Reference manual English Test cables 1 x red 1 x black RS232 cable 9 pin JOFRACAL calibration software CTC 140A only Matching insulation plug kit 3 pcs CTC 1200 A only Matching Insulation plug kit 3 pcs Inserts heat shield and cleaning brushes Always use the original inserts where material and physical dimensions have been optimized A drilling guide is included if you buy undrilled inserts The heat shield protects the sensor transmitter under test from the heated air Use the cleaning brushes to clean the borings in your inserts when necessary Insulation tube and pl
4. F aesatentaiccassddvinstancondoepenian 45 minutes Cooling time CTC 140 A 100 to 0 C 212 to 32 F o scciesnicecieitncdeceetiactecanvvececess 10 minutes 010 4 5 C 7 932 10 D P eosa 16 minutes 140 to 100 C 284 to 2 12 E oesceozectecus tosta tron aor oe o eas 2 minutes CTC 320 A 920 to 100 C 608 to 212 F io eccoetoa ee root odo nbn uei 16 minutes CTC 650 A 650 to 100 C 1202 to 212 F e 28 minutes CTC 320 B 320 to 100 C 608 to 212 F Loiesseesoscesosteneste Sota inen 22 minutes CTC 650 B 650 to 100 C 1202 to 212 F eene 65 minutes CTC 1200 A 1205 to 300 C 2200 to 572 F eec 120 minutes Switch input dry contact llc c aii Maximum 5 VDC Test CULTO iocos E Esai Maximum 2 5 mA JOFRACAL software Minimum hardware requirements for JOFRACAL calibration software e INTEL 486 processor PENTIUM 800 MHz recommended e 32 MB RAM 64 MB recommended e 80 MB free disk space on hard disk prior to installation e Standard VGA 800 x 600 16 colors compatible screen 1024 x 786 256 colors recommended e CD ROM drive for installation of the program e 1 free RS232 serial port KEY FEATURES Specification Sheet SS CP 2281 US PHYSICAL SPECIFICATIONS Automatic switch test Finds switching temp Open close hysteresis Slope rate programmable 0 1 to 9 9 C F Auto step
5. 00206 1059s 105108 124500 2mm o zs 100186 100206 105194 105199 124510 4mm 3mm Hamm oma 120433 orsse 105100 12064 120462 NA Hamm oma wA 100190 100008 120465 120468 WA smm os wa 0 9 1009 120466 149 NA bom emm ow wA 120009 2946 123487 312965 wa 5MM emm os na 120040 122517 120858 31296 WA Mult hole type 1 CTC 140 A Package of the 124679 124681 124685 124683 124687 124689 above inserts 3 16 in Multi hole type 1 Mot 128479 123475 123476 Spare part no for predrilled inserts imperial inch EMT um CTC 140A CTC 320A CTC 650 A CTC 320 B CTC 650B CTC 1200A wm corso oue 10095 corse exa 12m Multi hole type 2 CTC 140 A Uam 250 ore 100160 100199 ore exe 31240 i snem s2 ores oie 100200 ora exam 12513 Dmm so orae 100169 100207 corro exa 124405 nsnm sez oram ero oras orsa eee NA sein eas orae 0 2 100810 corsa exam NA 6 mm i Multi hole type 1 Hanem ss na eors some 105m cora NA CTC 320 A 650 A O m 4mm 60F354 60F418 60F377 60F446 Package onthe 124680 124682 124686 124684 124688 124690 above inserts 123480 3 123477 123478 3 8 in Multi hole type 2 Note 1 Use the insert code when ordered as the standard insert togeth
6. 25 7 mm 1 01 in CTC 320 CTC 650 B inner diameter 21 5 mm 0 85 in CTC 320 CTC 650 B lenght 200 mm 7 9 in CTC 1200 A outer diameter 25 mm 0 98 in CTC 1200 A inner diameter 22 mm 1 6 in CTC 1200 A Ienglibu ascavsticnnicesticcssdcacaxecicten 155 mm 6 1 in Weight of non drilled insert approximate SILIO M 75 g 2 6 oz C2 OA r r S 170 g 5 8 oz CICO 50A M eee 510 g 17 8 oz CFOS OB Mm 280 g 9 8 oz IB ea 860 g 30 3 oz CTO 200 A 460 g 16 3 oz Shipping including optional carrying case CTO TADA sireci E 12 5 kg 27 6 Ib 1 7 07 H 11 kg 24 Ib CGTC G50 A 12 kg 27 Ib upecc adc MM 13 5 kg 21 Ib TC lcg MCcKT 17 kg 37 Ib OTO T200 A E 18 kg 39 Ib Size L x W xH 507 x 232 x 415 mm 19 9 x 9 1 x 16 3 in Shipping without carrying case Gare riui A 10 kg 22 Ib CTC 320 A tte te ee senseatonie users we creed ap uieeeanacionns 8 kg 17 5 Ib ipei 9 5 kg 21 Ib A Size L x W x H 465 x 255 x 470 mm 18 3 x 10 0 x 18 5 in CTO a0 E 11 kg 24 Ib CEGO B qm 14 kg 26 Ib CTC 00 A ee 15 kg 32 Ib B Size L
7. are designed with one key one function logic This means that there are no sub menus or difficult to remember multiple keystrokes necessary to access primary functions The easy to read backlit display features dedicated icons which help in identifying instrument conditions and operational steps Set temperature The Up and Down arrow keys allow the user to set the exact temperature desired with a resolution of 0 1 Instrument setups The CTC series stores the complete instrument setup including engineering units stability criteria resolution display contrast slope ramp rate auto step settings and maximum temperature Stability indicator A bold checkmark on the display indicates that the calibrator has reached the desired set temperature and is stable The operator may change the stability criteria and establish a greater sense of security in the calibration results A convenient countdown timer is activated five minutes before the unit reaches stability Automatic switch test Operators can save a lot of time using the automatic ther moswitch test function to find values for the Open and Close temperatures Additionally this feature displays the hysteresis deadband between the two points The feature ensures a very high repeatability when testing thermoswitches Simply press the SWITCH TEST key to activate the function Auto stepping This feature saves manpower The operator may stay in the cont
8. as been on for 10 minutes Measuring time is 30 minutes Time to stability approximate SII HAO Ay m 5 minutes CTG 320 650 A B sccecccctccestcsemedecucsvetednestac acuceuwantdes 8 minutes CGI ZOO T EeE 20 minutes Accuracy SE mop LIE 0 4 C O 7 F CTC 320 ABL sees tecaceacins De eoe Deremate tacrinor Des x 0 5 C 0 9 F CTC 650 m 0 9 C 1 62 F CTO 650 B PECORE 0 6 C 1 08 F CTO 1200 D cm 2 0 C 3 6 F Specification when using the internal reference Load 4 mm OD refe rence probe in the center of the insert Immersion depth CTC 140 A insulation included 115 mm 4 5in CTC 320 A CTC 650 A CTC 1200 A 110 mm 4 3 in CTC 320 B CTC 650 B eei ite tier aue Eu ERre RUE 190 mm 7 5 in Well diameter GIL a EA EE E 19 2 mm 0 76 in GTC 320 7 C TO G50 eeunenn ainicin 26 mm 1 0 in gie orisek esa 27 mm 1 6 in Specification Sheet SS CP 2281 US Heating time CTC 140 A 7g 29 6 130 SF Sateen ii r Dues MEUSE 3 minutes 23510 140 C 7 T9 t0 284 F esineen odisti 15 minutes CTC 320 A 23 to 320 C 73 to 608 Fe cinese cicer erede beocs i pecu pus 4 minutes CTC 650 A 23 to 650 C 7 73 to 1202 F veicwiccwaineticvonmseandecserbnascens 10 minutes CTC 320 B 2310 320 C 7310 GOS T5 eessessse uncus ducun dU edi pOs 20 minutes CTC 650 B 23 t0 650 C 7 7310 1202 P ieeoe taucht se sop euh eee on ri 39 minutes CTC 1200 A 23101205 CF 73 to 2200
9. ates 65 F100 105173 Improve your calibration uncer tainty by insulating the sensor under test Minimize the heat dissipation from the top of the block and through the sensor under test This insulation is important for all dry block calibrators without the dual zone heating block SS CP 2281 US ACCESSORIES O O O O O O OOO Specification Sheet Part no Description 122832 Cleaning brush 4 mm 3 Pkg 60F174 Cleaning brush 6 mm 3 Pkg 122822 Cleaning brush 8 mm 3 Pkg 123469 Insulation plug kit for CTC 140 A only 3 pcs 124528 Reference sensor 04 5 mm x 500 mm type N for CTC 1200 A 124414 Insulation plug kit for CTC 1200 A 3 pcs 12 mm 2 in 124415 Insulation plug kit for CTC 1200 A 3 pcs 3 and 4 mm 1 8 in 124416 Insulation plug kit for CTC 1200 A 3 pcs 5 and 6 mm 1 4 and 3 16 in 124518 Insulation plug kit for CTC 1200 A 3 pcs 7 8 and 9 mm 5 16 in 124519 Insulation plug kit for CTC 1200 A 3 pcs 10 and 11 mm 3 8 and 7 16 in 124520 Suspension holder for sensors for CTC 1200 A Carrying case Option C The optional protective carrying case ensures safe transportation and storage of the instrument and all associated equipment Heat shield 104216 An external heat shield is availa ble and may be placed on top of the calibrator to reduce the hot air stream around the sensor under test This is especially important for testing thermocouples having head mounted transmitte
10. block profile This design heats up the CTC 320 A to maximum temperature in just 4 minutes and the CTC 650 A in only 10 minutes The fast performance of the heating block is due to the special profile that minimizes mass and yet still accepts an insertion tube with a 25 mm 1 in outer diameter This design is a balanced compromise between temperature stability homogeneity and rapid heating cooling Deep immersion depth The CTC 320 B and CTC 650 B models offer a deeper immer sion depth of 200 mm 7 9 in If you have liquid filled sensors or other sensors that require a deeper immersion depth look for the B versions While the units do not heat and cool as quickly as their shorter counterparts they offer the capability to accom modate longer sensors Peltier effect CTC 140 A The model CTC 140 A features Peltier elements In 1834 Jean Peltier a French physicist found that an oppo site thermocouple effect could be observed when an elec tric current was connected to a thermocouple Heat would be absorbed at one of the junctions and discharged at the other junction This effect is called the PELTIER EFFECT The practical Peltier element electronic heating pump consists of many elements of semiconductor material connected elec trically in series and thermally in parallel These thermoelectric elements and their electrical interconnections are mounted between two ceramic plates The plates serve to mechanically ho
11. er with a new calibrator 1 8 in Note 2 CTC 140 A only Remember to use matching insulation plugs see accessories 3 16 in Note 3 CTC 140 A only All multi hole inserts are delivered with a matching insulation plug 1 4 in Note 4 CTC 1200 A only Remember to order matching insulation plugs see accessories Multi hole type 2 CTC 320 A 650 A A ORDERII LIA IRI PFs A y Vira WE a edm 7 B is x P a NF e NIS al Vv 8g nr NA NU JS IVE AE Wet EWE 4 LEAF um d Order number Description Base model number CTC140A CTC 140 A 17 to 140 C 1 to 284 F CTC320A CTC 320 A 33 to 320 C 91 to 608 F CTC650A CTC 650 A 33 to 650 C 91 to 1202 F CTC320B CTC 320 B 33 to 320 C 91 to 608 F CTC650B CTC 650 B 33 to 650 C 91 to 1202 F CTC1200A CTC 1200 A 300 to 1205 C 572 to 2200 F Power supply US deliveries 60 Hz only 115 115VAC 230 230VAC AMETEK Calibration Instruments is one of the world s leading manufacturers and Mains power cable type developers of calibration instruments for A European 230 V temperature pressure and process signals B USA CANADA 115 V as well as for temperature sensors both from a C UK 240 V commercial and a technological point of view D South Africa 220 V JOFRA Temperature Instruments E Italy 220 V Portable precision thermometers Dry block and F Australia 240 V liquid bath calibrators 4 series with more than 25 models and temperature ranges f
12. esseeeceesseeeseeeeeees 0 1 to 9 9 minute Maximum temperature Any value within range Miscellaneous Serial data interface HS232 9 pin Male Operating temperature 0 to 40 C 32 to 104 F Storage temperature 20 to 50 C 4 to 122 F ain de O to 90 RH Protection Class NI E IP 10 DNV Marine Approval Certificate no A 9557 a i a e P Instrument dimensions CTC 140 A CTC 320 A CTC 650 A LXW x Hi Lies 241 x 139 x 325 mm 9 5 x 5 5 x 12 8 in CTC 320 B CTC 650 B CTC 1200 A LXxW xH 241 x 139 x 408 mm 9 5 x 5 5 x 16 1 in Instrument weight CIC 4OAJCIC 920 B cseccwwicctcencnarecsaneaseunnecess 7 kg 15 5 Ib PILOS AE m 5 kg 11 Ib 1e 0 6 kg 13 Ib C6 OB 10 5 kg 23 Ib aire A 12 kg 26 5 Ib Insert dimensions CTC 140 A outer diameter 19 1 mm 0 75 in CTC 140 A inner diameter 15 0 mm 0 59 in CTC 140 A lenght eese 100 mm 3 9 in CTC 320 CTC 650 A outer diameter 25 7 mm 1 01 in CTC 320 CTC 650 A inner diameter 21 5 mm 0 85 in CTC 320 CTC 650 A lenght 120 mm 4 7 in CTC 320 CTC 650 B outer diameter
13. ld the overall structure together and to electrically insulate the individual elements from one another Maximum temperature From the setup menu the user can select the maximum tem perature limit for the calibrator This function prevents damage to the sensor under test caused by the application of excessive temperatures The feature also aids in reducing drift resulting from extended periods of exposures to high temperatures This feature can be locked with an access code Specification Sheet SS CP 2281 US MVI Improved temperature stability MVI stands for Mains power Variance Immunity Unstable mains power supplies are a major contributor to on site calibration inaccuracies Traditional temperature calibrators often become unstable in production environments where large electrical motors heating elements and other devices are perio dically cycled on or off The cycling of supply power can cause the temperature regulator to perform inconsistently leading to both inaccurate readings and unstable temperatures The CTC series employ the MVI thus avoiding such stability problems The MVI circuitry continuously monitors the supply voltage and ensures a constant energy flow to the heating elements Easy to use intuitive operation All instrument controls may be performed from the front panel The heat source is positioned away from the panel This design helps to protect the operator The main functions on the CTC series
14. lity circuitry and calibration software Both speed and portability are superior to liquid baths Dry block calibrators do not require hazardous liquids and provide a wide temperature range Calibrate your RTD s thermocouples thermoswitches thermistors and other common temperature sensing devices n 4g F ke Ab e Id The CTC series is designed for both on site and maintenance shop use The applications are generally critical process control but can vary based on calibration and testing requirements The user interface is easy and intuitive One key one function gives you quick access to timesaving features such as the switch test or the auto stepping function All models feature a large backlit LCD display panel which is easy to read even in well lit areas Units feature an informative display that provides icons and information regarding the status of the CTC and the calibration in progress The JOFRA CTC series consists of six different models that differ in temperature ranges and immersion depths All units offer similar features A rugged slim line alu minum outer casing with die cast top and bottom protects the CTC series of dry block calibrators For easy documentation and automatic calibration all units are delivered with RS232 serial communication and JOFRACAL calibration software AMETEK CALIBRATION INSTRUMENTS Fast heating and cooling The CTC 320 A and the CTC 650 A contain an innovative heating
15. ping mie AMIENS f T Up to 9 steps Dwell time on each step Programmable Enhanced stability Unstable mains protection MVI Circuitry Clear stability indication Yes in display Multi information display Stability indicator esesssessess Bold checkmark Countdown timer before stable 4 minutes Temperature SET and READ simultaneously Alphanumeric messages esee Yes Calibration status ICOflS eo oon ectetuer ranae Se anuo Yes Training mode heating cooling block disabled Simulation of all functions eeeeeeeeeeeneeeeees Yes Simulating heating and cooling Approx 100 per minute Service facilities Adjustment of the unit from the keypad Yes Self explaining guide in display Yes Other information Displays serial number T software revision level and last calibration date Setup facilities Stability CMe Niet NE ETE TE Extra time before n stable indication is shown Display resolution eeeeeeeeeeeeeees 0 1 or 1 C F Temperature units sse C or F Slope rate cccceeecceccsseeeece
16. rol room or another remote location monitoring the output from the sensor under test while the CTC series calibrator is placed in the process and automatically changes the tempera ture using a programmed step value and rate Up to 9 different temperature steps may be programmed including the hold time for each step AMETEK Re calibration adjustments The CTC series has a very easy and straightforward procedure for re calibration adjustment There is no need for a screwdriver or PC software The only thing you need is a reliable reference thermometer Place the probe in the calibrator and follow the instructions on the display Third party labs and calibration facilities will be able to perform this function if a certificate from an independent source is necessary Of course AMETEK can provide you with a traceable calibration certificate from our labs when you require a higher level of confidence Liquid filled sensors and switches The tall B models with an immersion depth of 190 mm 7 5 in are ideal for calibration of liquid filled sensors The specially designed non linear heating ele ments in the CTC 650 B and the increased block mass provide a very homogeneous temperature throughout the block It is essen tial for the quality of the calibra tion test that the full lenght of the sensing part of the sensor is exposed to the same temperature Calibrate analog reading devices or switches with very high repeat ability
17. rom G Denmark 230 V 90 to 1205 C 130 to 2200 F All featuring speed H Switzerland 220 V portability accuracy and advanced documenting Israel 230 V functions with JOFRACAL calibration software Insert type and size JOFRA Pressure Instruments XXX 1 x Insert for dry block configuration Convenient electronic systems ranging from l 1 to 1000 bar 25 inHg to 14 500 psi please see the previous insert pages for the multiple choices of pressure ranges pumps and right insert codes accuracies fully temperature compensated Calibrati tificat for problem free and accurate field use aliDration certificate F NLP Traceable temperature certificate JOFRA Signal Instruments standard for Europe Asia Australia and Africa Process signal measurement and simulation for easy m control loop calibration and measurement tasks G NIST traceable temperature certificate from handheld field instruments for multi standard for Western Hemisphere or single signals to laboratory reference H Accredited certificate with 5 std points coeno missione except CTC 1200 A JOFRA JF Marine Instruments H Accredited certificate with 4 std points A complete range of calibration equipment for for CTC 1200 A temperature pressure and signal approved for marine use Options C anims case FP Temperature Sensors A complete range of temperature sensors X No option used for industrial and marine use CTC650A230AMO1FX Sample order number M amp G Pressilre Te
18. rs with cold junction compensation FUNCTIONAL SPECIFICATIONS Mains specifications Voltage CTC 140 320 650 1200 115V 90 127 230V 180 254 Voltage CTC 650 B 115V 105 127 230V 210 254 Frequency non US deliveries 50 Hz x5 60 Hz x5 Frequency US deliveries 60 Hz x5 Power consumption max CTC 140 A 150 VA Power consumption max CTC 320 B 600 VA Power consumption max CTC 1200 A 650 VA Power consumption max CTC 320 A 650 A B 1150 VA Temperature range CTC 140 A Juzb e O 9 E E 140 C 284 F Minimum ambient temp 0 C 32 F 30 C 22 F Minimum ambient temp 23 C 78 F 17 C 1 F Minimum ambient temp 40 C 104 F 2 C 28 F CTC 320 AB wrreiiettecemienaccicd 33 to 320 C 91 to 608 F CTC 650 AJ B eee 33 to 650 C 91 to 1202 F CTC 1200 A 300 to 1205 C 572 to 2200 F Resolution user selectable Selectable NR NETTE 1 or 0 1 C F Stability eec 0 05 C 0 09 F CTO 9320 AID sccricctanazedavideenaiecasinderessetiawnneiuns 0 1 C 0 18 F CTC 650 A 7 1200 Ay vacsaviencscacussncsnchisiinzeusensaneaaiee 0 1 C 0 18 F OB 0 05 C 0 09 F Measured after the stability indicator h
19. sters AMETEK CALIBRATION INSTRUMENTS JOFRA CTC 650 A dry block 230 VAC power with European power cord and insert Pre drilled multi hole type 1 1 x 3 mm 1x4 mm 1 x5 mm 1 x 6 mm 1 x 9 mm and NLP traceable certificate Pneumatic floating ball or hydraulic piston deadweight testers easy to use with accuracies to 0 015 of reading Decause calibration Is a matter of confidence TRANSCAT 3o Vantage Point Drive Rochester NY 14624 1 800 800 5001 Information within this document is subject to change without notice 2007 by AMETEK Inc www ametek com All rights reserved Pub code SS CP 2281 US Issue 0706
20. x W x H 465 x 255 x 470 mm 18 3 x 10 0 x 18 5 in Shipping carrying case only WONG M E 5 0 kg 11 Ib Size L x W xH 507 x 232 x 415 mm 19 9 x 9 1 x 16 3 in Specification Sheet SS CP 2281 US Inserts for CTC 140 A and CTC 320 A B are made of aluminum Inserts for CTC 650 A B are made of brass Inserts for CTC 1200 A are made of high temperature steel alloy All specifications on hole sizes are referring to the outer diameter of the sensor under test The correct clearance size is applied in all predrilled inserts Undrilled inserts Inserts undrilled CTC 140 A inserts 0 CTC 140 A CTC 320 A CTC 650 A CTC 320 B CTC 650 B CTC 1200 A z pace unanig 60F448 100175 100194 60F356 60F420 124403 Undrilled 4 mulation plug 123997 see below Spare part no for predrilled inserts metric mm Undrilled inserts Lo nstruments 1 CTC 320 650 A B Probe diameter CTC 140A CTC 320A CTC 650 A CTC 320 B CTC 650B CTC 1200A 003 12948 vemm 004 60F45 100177 100196 60F359 60F423 124400 5mm 005 1294290 129487 128445 123452 123460 124504 emm oo 60r453 100179 100198 60F36 GoF425 124407 famm o8 1 05 85 toore 00 00 105190 105105 124506 amm o 105186 1008s 10002 1051 105196 124507 Undrilled inserts Homm mo 15 5 00 55 105188 1051 105107 124508 CTC 1200 A tmm on 120431 1008s 1

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instrucciones Washlet E200  User's manual FLIR Exx series  平成19年度 択一試験過去問  SERVICE MANUAL - PhilipsRadios.nl  Quick User Guide  ROBOT魂 SIDE MS G-3ガンダム(メタリックコート仕様) 取扱説明書  Curtis LCDVD156 Flat Panel Television User Manual  "La Cote d`alerte" (production pour la télévision - unesdoc  Bosch DKE 950x Kitchen Hood  スカイ”一 "エース  