Home
User Manual
Contents
1. ADD SATA HDD Unsupported SAS amp SATA HDD Combinations VU V g o gt Do not include SAS and SATA HDD in the same section SAS HDD SATA HDD DNS 1640 User Manual Follow these steps below to Install Replace HDD in the disk tray Step 1 a Press the release button and open the disk tray handle b Remove HDD carrier by pulling the disk tray handle out DNS 1640 User Manual Step 2 Insert the HDD inside the tray and tighten the four 6 4 screws on the SATA SAS disks SATA disk SAS disk a es EN ee ij is N F a F ia es j Bay N Interposer for SATA LE Important If using SATA HDD please make sure having DNS BJMB Interposer card installed on the back of HDD 10 DNS 1640 User Manual Step 3 Slide in the HD tray back in the disk slot and close the disk tray handle Step 4 Repeat Step 1 through 3 if you wish to install more HDD into the DNS 1640 storage 11 DNS 1640 User Manual Before You Begin Important Before you set up the DNS 1640 system be sure your facility meets the following conditions Confirm that there is adequate power at your facility to support the high availability features of the system It is recommended to connect each power connector to separate power circuit If necessary refer to the documentations shipped with the 6Gb s SAS HBA RAID card for hardware and driver installation instructions There
2. Model Model DNS 1640SM DNS 1640DM DNS 1640S DNS 1640D Hard Drive Type SATA SSD SATA SSD SAS SSD SAS SSD SAS 1 O Module 1 2 1 2 DNS B MB 12 12 0 0 2 5 Interposer Technical Support Contact your system supplier DNS 1640 User Manual DNS 1640 Overview LEDs on the Storage Enclosure No Component Lights On Lights Off 1 Fault LED Amber A component within the storage en Normal closure needs attention 2 Locate LED Flashing Blue Identifies a storage enclosure Normal 3 Power Power On Power Off DNS 1640 User Manual DNS 1640 Single SIM Rear View SIM SAS IN 2 SAS IN 1 SAS OUT Board 1 Connector Connector Connector Power Supply Power Supply Module 1 Module 2 Power Connector DNS 1640 Dual SIM Rear View SIM ae 2 Board 1 SAS IN 2 SAS IN I SAS OUT SAS IN 2 SAS IN I SAS OUT Connector Connector Connector Connector Connector Connector Power Supply Power Supply Module 1 Module 2 Power Connector Important Note the direction of the power supply unit Insert the power supply with the right direction All SAS IN amp OUT connectors are SFF 8088 DNS 1640 User Manual DNS 1640 SIM Board LED Description dataO i A Ol PRESS VAN RE Oar BE Consoles for factory use only 7 8 9 1 SAS IN 2 Fault Amber PHY connection cannot estab No error had occurred lished correctly 2 SAS IN 2 Active Green PHY connection established No connection correctly SAS IN 1 Fault
3. Power Strip 1 4 Connect the power cables from the cabinet to separate power circuits in your facility Note Cabinet is not included in the package Only the universal rails kit for the cabinet are provided 15 DNS 1640 User Manual Power on the DNS 1640 1 Verify that all connections are correct 2 Turn on both circuit breakers on cabinet 3 Make sure that power on LED on all DNS 1640 are steady blue 4 Power on the host lastly Important Please make sure power on all DNS 1640 first before the server 16 DNS 1640 User Manual Features and Specifications DNS 1640 is a high availability cost effective 2U SAS Serial Attached SCSI to SAS Serial Attached SCSI J BOD which provides 24 pcs 2 5 hard drive camersto support varous types of hard drive including 6Gb s SAS hard drive and 6Gb s SATA Ill hard drive with in termoser card In addition to 24 pcshard drive camers DNS 1640 system supports two 550W Full Redundant Power Supplies and two SIM modules High Reliability Redundant SIM modules power supplies modules design secure No Single Point Failure Active Active Dual 6Gb sSASI O Module Architecture hot swappable hard disk and dual SASand SATA Il paths with Intemoser Card ensure that DNS 1640 has high reliability and achieves 24x7 availability High Scalability Each DNS 1640 system sup portsa maximum of 24 6G b s SAY SATAIII hard disks persystem and up to 96 dnves by daisy chaining J
4. Amber PHY connection cannot estab No error had occurred lished correctly SAS IN 1 Active Green PHY connection established No connection correctly SAS Out Fault Amber PHY connection cannot estab No error had occurred lished correctly SAS Out Active Green PHY connection established No connection correctly Flashing Blue Identifies SIM Normal SIM Fault Fault exist Normal SIM Power Power On Power Off W Ul 0 00 d O DNS 1640 User Manual DNS 1640 PSM Board LED Description 2 Identifies Power Module DNS 1640 User Manual Disk Drives Front LED and Tray LH Optional DNS B MB 9252 6Gb s SAS ly Interposer for 2 5 thon ate SATA SSD HDD Do Release button Disk Tray Handle 1 SAS HDD is ready SATA will be blank Blinking Or RAID Rebuilt ange amp Blue a Blinking Blue HDD is ready to remove HDD Activity LED will be blank DNS 1640 User Manual Install Replace HDD Before You Begin It is not recommend mixing different RPM SAS and SATA HDD in the same DNS 1640 system If you have to please use the following figures below to plan where you will be placing the disk drives These figures represent fully loaded DNS 1640 system with HDD However the same guidelines apply even if you are filling some of the HDD slots with blank disk trays in the mix ing HDD setting Recommended Mixing SAS amp SATA HDD Configurations 7 E gt gt
5. BOD High Hexibility DNS 1640 system supports both SAS and SATA disks depending on cus tomersneeds This feature provides the most cost effective storage pools for different kinds of data and providesa better management for ILM Information Life Cycle Management applications High Performance The Active Active Dual 6Gb sSASI O Module Architecture ensures high system performance Features Redundant SIM Modules and Power Supplies Active Active Dual 6GB s SASI O Module Ar chitecture Support full path fail over function which pro vides data redundancy Support Dnve Auto Detection and Hot Swap Integrated RAID card management tool via SES2 Connectivity Features Two 6Gb sSASIN portsin each SIM module provides host connectivity Support up to 96 drives by daisy chaining J BODs Connected and managed by RAID controller Connect to 6Gb s SAS Expander Support Direct Attach Support daisy chain of J BODs 17 DNS 1640 User Manual Host Interface AC Power Em 7wo 6Gb s SAS n ports on each SIM module M nput Voltage 100 240 VAC m One 6Gb s SAS Out ports on each SIM module m nput Frequency 50 60Hz E Output Power 550W Hard Disk Interface utpu wW E 24 x dual ported SAS 6Gb s or SATAII hard disks with DNS B MB 9252 6Gb s SAS interposer 6Gb s E Operating Temperature 0 to 35 degree Celsius E Up to a maximum of 24 disks per J BOD E Operating Humidity 20 to 95 non condensing m By daisy chain
6. are different types of SAS Cables in the market make sure you order the right one for DNS 1640 For DNS 1640 it all uses SFF 8088 to SFF 8088 SAS Cable when connecting DNS 1640 to host and when daisy chain to another DNS 1640 SFF 8088 to SFF 8088 SAS Cable a hearr narr BAI 12 DNS 1640 User Manual 1640 System DNS Setting up le SIM ing Connection type 1 S This illustration shows one host with a HBA RAID card connected to four DNS 1640 with single SIM RAID HBA CARD 2 Te O un lt un CO CO CO I LL LL un Oo WH CO CO CO I LL LL un lt t O l N Z m 2 DNS 1640 3 DNS 1640 4 DNS 1640 13 DNS 1640 User Manual Connection type 2 Dual SIM This illustration shows one host with a HBA RAID card connected to four DNS 1640 with dual SIM Important Not All HBA RAID card support this type of connection please refers to DNS 1640 support matrix reference for complete listing of supported dual port HBA RAID cards RAID HBA CARD SFF 8088 to SFF 8088 SAS Cable 1 DNS 1640 2 DNS 1640 3 DNS 1640 4 DNS 1640 14 DNS 1640 User Manual Connecting Power to DNS 1640 Important DNS 1640 is recommended to be installed in Dual power strip cabinets 1 Ensure the cabinet circuit breakers are in OFF position 2 Connect the two provided power cables from the DNS 1640 to cabinet power strips 3 Lock down the two power cord latch
7. ie On Better Storage Agile Solution DataONSIORAGE 2U 24 Bays 6Gb s SAS JBOD Dual path Dual I O User Manual Copyright 2011 DataON Storage All rights reserved www dataonstorage com Copyright This publication including all photographs illustrations and software is protected under international copyright laws with all rights reserved Neither this manual nor any of the material contained herein may be reproduced without the express written consent of the manufacturer Copyright 2011 DataON Storage Inc Trademarks All product names used in this manual are the properties of their respective owners and are acknowledged Disclaimer The information in this document is subject to change without notice The manufacturer makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose Furthermore the manufacturer reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of the manufacturer to notify any person of such revision or changes Safety Measures Computer components and electronic circuit boards can be damaged by discharges of static electricity Working on computers that are still connected to a power supply can be extremely dangerous Follow these guidelines to avoid damage to the DNS 1640 or injury to yourself e Always disc
8. ing JBODs up to 96 disk drives supported E Altitude 50 to 10 000 feet E Shock 31G 2 6ms sine wave pulse Redundant Hot Swappable Components m Vibration 0 25G 3Hz to 200Hz E 2 S M Modules m 2 Power Supply Modules E up to 24 SAS SATAII hard disks FCC class A under 3dB Form Factor CE Specifically requirements in effect J uly 1 2001 Operating Environment Electromagnetic Emissions Standards M nternal Bays 24 2 5 Hard Disks Safety Standards ae MOUNTE Se MEA IED UL CUL for U S with Canada Dimensions The chassis dimensions measured at 17 5 W X 6 875 H X 18 5 D Sheet metal case only not including bezel and rear module handle Management Features E ntergated with RAID Card management tool via SES2 M LED Indicators for SM Modules Hard Drives Power Supplies and FAN Status 18
9. onnect power when carrying out work inside the unit e If possible wear a grounded wrist strap when carrying out work inside the unit Alternatively discharge any static electricity by touching the bare metal chassis of the unit case or the bare metal body of any other grounded appliance e Hold electronic circuit boards by the edges only Do not touch the components on the board un less it is necessary to do so Do not flex or stress the circuit board e Leave all components inside the static proof packaging until you are ready to install the compo nent Equipment Location This equipment should only be accessed by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location Access is through the use of a TOOL or lock and key or other means of security and is controlled by the authority responsible for the location About this Guide This guide describes how to setup and power on the DNS 1640 6Gb s SAS J BOD system This guide is intended for trained personnel only DNS 1640 User Manual Package content The DNS 1640 box contains the following items e DNS 1640 Storage unit 1 e Power cord 2 e CD with user manual and drivers 1 e Universal Rail Kit for DNS 1640 1 e HDD Screws 96 System requirements e Servers with supported HBA Raid adapter refer to DNS 1640 support matrix reference for complete listing of supported adapters e SFF 8088 to SFF 8088 SAS cable s