M181 I.V. PAD - sakamoto model corporation
Contents
1. 4 5 6 7 8 9 When dying water in order to simulate blood use our Stock Solution for Simulated Blood sold separately and dilute it with water If a dark colored solution higher concentration is used the ink may stain the injection area on the skin Be careful that the connector in the middle of the tube does not disconnect accidentally during use Use new needle tips when performing injection training with this product Otherwise it can cause the skin of the I V Pad to deteriorate Never inject the needle in an upright direction nor use excessive force that may pierce all the way through the I V Pad Doing so is extremely dangerous and can cause serious injury When using this product for training purposes conduct the training in pairs with one person playing the role of the patient and wearing the I V Pad If a defect or problem with the product is discovered during use stop using the product immediately and contact Sakamoto Model This product is a simulator capable of supporting advanced medical training However Sakamoto Model does not guarantee the same results during actual treatment Please note that the specifications of this product may be changed without prior notice in order to make improvements to the product If the blood vessel is accidentally removed from the I V Pad Refer to the next page for item 9 If the blood vessel is accidentally removed from the I V Pad
2. 9 If the blood vessel is accidentally removed from the skin section of the I V Pad connect it to one side of the stick for exchanging vessels and then insert the stick and vessel into the I V Pad Refer to the pictures on the right Instructions for Use When using this product for the first time refer to step 8 on the next page Steps 1 7 Blood vessel exchange procedure Refer to the pictures on the right We recommend exchanging the blood vessels before each training session in order to prevent the I V Pad from leaking 1 Disconnect the U shaped tube on one side The connector stays connected to the U shaped tube 2 Connect the exchangeable blood vessel to the connector on the U shaped tube 3 Open and unroll the I V Pad so it is flat 4 Pull the blood vessel from the opposite side so the tube that is inside the I V Pad is changed out If part of the connector gets caught gently pull the tube through without forcing it 5 Remove the blood vessel that is no longer needed and reconnect the connector on the U shaped tube 6 Change out the other tube on the opposite side following the same procedure 7 Ifthe blood vessel is not straight or winds through in an S shape open and unroll the I V Pad so it is flat Then pull on both ends of the blood vessel as the I V Pad rolls back up and the tube should straighten out Refer to the next page to continue to step 8 8
3. 9 10 11 12 13 Connect the silicon tube with the white clasp to one side of the blood vessel in the I V Pad and to the receptacle Connect the silicon tube with the yellow clasp to the other side of the blood vessel in the LV Pad Close the yellow clasp and fill up the receptacle with water approximately 250 ml Open the yellow clasp to fill up the tube with water Have a tray or container ready because the water will discharge Loosen the cap on the receptacle if the water does not discharge The I V Pad uses an arm band that naturally fits and curls around your arm Open the arm band to fit it onto a person playing the role of the patient or onto a dummy model Use this product to carry out training When exchanging the blood vessel during training close the white clasp and disconnect the silicon tube with the white clasp from the I V Pad Have a tray or container ready because the water will discharge Thereafter disconnect the silicon tube with the yellow clasp from the I V Pad and exchange the vessel following steps 1 through 7 under the Instructions for Use Storage Instructions 1 Close the white clasp and disconnect the silicon tube with the white clasp from the I V Pad Have a tray or container ready because the water will discharge 2 Discharge the water that is inside the tube and the receptacle 3 Disconnect the silicon tube with the yellow clasp 4 Dry out each p
4. M181 I V PAD S SAKAMOTO MODEL CORPORATION User s Manual 130502 INDEX introduction Table of Contents Purpose Content Cautions on Use Instructions for Use Storage Instructions NI Ol ND oO A Confirm the main unit and accessories directly after the product arrives If there is any defect or breakage inform the dealer or Sakamoto Model PAZ RALT IL l Introduction Thank you for purchasing our product I V PAD Read this user s manual carefully in order to use the product for a long time appropriately This product is closely checked before factory shipment However when this product arrives open it soon and check if anything on the main unit and accessories are missing or broken Table of contents Introduction Table of Contents ccceeeeeseeeeees 1 Purpose Content eniron ie es A E aca 2 Cautions om Usean raae s a a E E Eaa 3 4 Instructions for Use cccccccccccscocccccccccccccececs 5 6 Storage NSH UCTIONS nesses annen ai aani T Purpose Content 1 2 3 1 Intravenous injection training 2 Blood sampling training I V Pad training kit 5 pcs 5 sets LV Pad U shaped tube Receptacle Silicon tube with yellow clasp Silicon tube with white clasp Exchangeable blood vessel standard Qty 10 Stick for exchanging vessels Qty 1 Cautions on Use 1 2 3
5. art at room temperature 5 Roll up the silicon tube with the yellow clasp and the silicon tube with the white clasp Place them as well as the receptacle inside the I V Pad Then put the whole I V Pad training kit inside a bag to store it 6 Avoid storing the product in direct sunlight or in locations with high temperature and humidity SAKAMOTO MODEL CORPORATION Head office 34 Higashitakagicho Shimogamo Sakyo ku KYOTO 606 0865 JAPAN Phone 81 75 701 1135 Fax 81 75 722 5638 E mail info sakamoto model com URL http sakamoto model co jp Overseas Sales Department 9 29 Senbahigashi Minoh City Osaka 562 0035 JAPAN Phone 81 72 729 8350 Fax 81 72 729 8385 E mail trade sakamoto model com
Download Pdf Manuals
Related Search
Related Contents
薬食発033 ー第30号 平成2 3年3月 3 ー 日 Comparison of Five On-Head, Eye-Movement UDG 4500600 Fiche Pratique : Créer une Page Facebook Professionnelle 取扱説明書 盗難発生警報装置 EASY RAIN™ - Rain Bird 『MDX-D7100』の取扱説明書がダウンロードできます。 view users manual Pro-Ject PRO-JECT DEBUT III E User's Manual Mode d`emploi Babyface Copyright © All rights reserved.