Genrakode™ Test Unit User`s Manual

image

Contents

1. lt lt Modify Code T Location IDs P2160TU Rev Sept 02 Enter number between 1 and 27 Enter East Code T Location ID Enter West Code T Location ID gt gt between 1 and 27 between 1 and 27 11 Transmit Code between 1 and 8 ALSTOM Signaling Inc As noted previously the default number of Code T parameters per location for the test unit is set to 8 This can be changed to 4 to support interfacing with older PGK applications To do so use the TPL command Be aware that since this affects the formatting of the Code T message the test unit should be reset to begin any Code T transmissions again Enter for Command Summary GTU gt tpl Number of Code T Parameters Per Location 8 lt lt Modify Number of Parameters Per Location gt gt Enter 4 for 4 Parameters and 8 for 8 Parameters Number of Parameters gt 4 Reset Test Unit To Ensure Proper Code T Operation DISCONNECTING When testing with the test unit is complete simply disconnect the track and power leads from the Genrakode module under test Then the Genrakode module can be reconnected to any tracks or Track Interface modules that were disconnected prior to testing P2160TU Rev Sept 02 12 ALSTOM Signaling Inc APPENDIX A FLASH UPGRADING Flash upgrading the test unit system software is a quick and easy procedure Before proceeding ensure that you have all the necessary hardware and software
2. r for Command Summary Ente GTU gt mts Code East Code T West Track Operation Track Operation lt lt Modify Code T Settings gt gt DISABLE DISABLI Enter 0 to DISABLE 1 to ENABLE Code East Code T West Track Enable gt 1 Track Enable gt 1 Code T can also be enabled or disabled without requiring the use of the serial interface To do this turn the unit off set the Code 5 type switch to the F2 position set the Code T switches to the Code T selection to enable Code T for that track or to the OFF selection to disable it and turn the unit back on Once the unit has powered up the switches may be put back to their desired positions For example setting the West Code T switch to Code T and the East Code T switch to OFF in the above procedure will enable West Code T and disable East Code T Setting the trouble code and location ID to be transmitted is done via the serial interface using the TCD and TID commands Enter for Command Summary GTU gt tcd East Transmit Code T 1 West Transmit Code T 1 lt lt Modify Code T Transmit Codes gt gt Enter numbe East Enter West GTU gt tid East Code T West Code T Location ID Location ID r between 1 and 8 ransmit Code between 1 and 8 Enter for Command Summary
3. Dloadwin exe the Windows PGK Download program The PGK Dloadwin program as of version 2 0 has an option to download to the test unit See instructions below GCTUSYSP HEX the system software file The size of this file should be 276 527 bytes A laptop or personal computer running Microsoft Windows A null modem serial cable or a straight through cable with null modem adapter with a DB 9 connector To begin the flash upgrade process connect the serial cable from the test unit to the computer and run the Dloadwin application To do so from Windows navigate to the application using Windows Explorer and double click on the application If the serial port being used on the computer is not com 1 go to Configure gt Com Port and choose the correct port being used Go to Actions gt Terminal Mode or click on the toolbar button to enter the terminal view Then power up the test unit being ready to press lt Enter gt when prompted to enter the bootloader monitor See Figure A 1 below If the MON gt prompt does not appear power cycle the test unit and try again Once at the MON gt prompt go to Actions gt File Mode to leave the terminal mode D Untied gt Crea la Flo doko Cages Hop ele ulm e 18 Code Tear Unit Baceiran Version 2 00 06 14 7007 Copyright ALSTON Signaling Enc 2012 ALI Fighis Remerred Enis E Dansi E Fede Ha Figure A 1 Entering Monitor Mode to Prepare for Download
4. P2160TU Rev Sept 02 13 ALSTOM Signaling Inc Since this download application is normally used for downloading software to a PGK module go to Configure gt Options gt Test Unit to change to Test Unit Mode See Figure A 2 below Untitled Dramas bg brake Bla Ee Hale CoP 5 Application de Fla Ordo Appliesti n ID ion Compil le Bet Fl On Application Compila Both Aap and Syn dipplicetion Checker Applicstion CRC ner Checker 1 Site TD Module Comdigoration TD Cal Version CL Congpdla Date CAR Product Hubar Dr W CEC Serial Gusher Sagnal Type Met Flash Rate Series Hoe File Dimeja Mew Leire lo Eee Taai Line Figure A 2 Choosing Option to Enter Test Unit Mode Once in Test Unit Mode the File view will display test unit specific information Go to File gt Open to select the system software hex file Browse for the gctusysp hex file See Figure A 3 Tent limit Copiar Syria SY Verriza SoLo a a nadya a Figure A 3 Dloadwin in Test Unit mode Choosing File to Download P2160TU Rev Sept 02 14 ALSTOM Signaling Inc Finally to begin the download process go to Actions gt Download The download process will take a few minutes to complete Status information will be displayed in the download application throughout the process See Figure A 4 below Foe Wire Corrakodo T
5. Remember to take note of the tap settings before adjusting them so that they can be returned to the correct position after testing POWER UP SEQUENCE Once the track and power leads are connected power up the test unit and the module under test if not already powered up If the test unit is operating properly all segments of the 14 segment displays should immediately illuminate for a brief period to test the displays Following this test while the unit is initializing the unit should display P UP and illuminate both Code 5 LED s This entire process should take no more than seven seconds Then the 14 segment LEDs will show the test unit s configuration settings For each display West and East the first character displays the DC Normal vs Transit mode for that track and the second character displays if code T is enabled for that track So Nd means Normal mode and code T disabled NT means Normal mode and code T enabled and T means Transit mode and code T is not applicable Note that in AC mode neither of these settings will be used P2160TU Rev Sept 02 5 ALSTOM Signaling Inc but are displayed Upon completion of power up the 14 segment LEDs will show a single dash in each direction To change modes see the sections entitled DC Transit vs Normal Mode and Code T later in this manual In the event of a failure with the system software on the test unit the test unit will remain
6. display the DC Normal vs Transit setting and the Code T enable settings Unidad Dorie la Wanker Fle does Lonas e Hele a je cll Carracda Coda Taat Unit Bociatirap Version 2 00 06 13 2002 Copyrig cr ASTM agnalsos Cree 2002 All Fightin Porrera Entering SCT Enteractina Exvircoment IC Node gt Hormal iF Track 1 Coda T Ecabled TI Track 2 Coda T Erabl d Ti GU Version 2 40 06 19 2007 Cole Test Daa 5216 Copyright ej SESTOH Signaling Eres 2007 411 Rights Reser Bair i fer Commend Summare Esto Hui Figure 4 2 Startup Diagnostic Messages and GTU Prompt P2160TU Rev Sept 02 7 ALSTOM Signaling Inc TRANSMITTING AND RECEIVING CODES After the test unit has powered up codes successfully received from each set of track leads will automatically appear on the corresponding two digit 14 segment display If Code 5 is received the appropriate Code 5 LED located next to the two digit display will illuminate The test unit determines what code s to transmit based on the switch settings as well as the configuration of certain settings stored in nonvolatile memory and changed via the serial interface see below The various switches that control the codes transmitted are as follows e Code Select selects the code to be transmitted DC codes are marked in blue while AC codes are marked in red At the time of this printing valid DC codes are Code 1 through Code 9 while valid
7. the unit will not actually transmit a signal This switch is especially useful to simulate a loss of signal to the Genrakode Module due to track shunting Note that the test unit will continue to receive codes regardless of the position of the Transmit Enable switch A serial configuration setting TOL allows for specifying the length of the codes transmitted by the test unit Available lengths are MINIMUM NOMINAL AND MAXIMUM This command enables testing of receive tolerances of the module under test For example the nominal pulse width of a Code 1 in Normal DC mode see below for a discussion of Normal vs Transit DC modes is 112ms The minimum specified pulse width is 64ms and the maximum is 160ms See the ALSTOM Genrakode Genrakode II and AC Genrakode Manuals for more details on the pulse width and pulse spacing tolerance specifications Below is an example of using this serial command P2160TU Rev Sept 02 8 ALSTOM Signaling Inc Enter for Command Summary GTU gt tol East Track Tolerance Mode NOMINAL West Track Tolerance Mode NOMINAL lt lt Modify Tolerance Mode Settings gt gt Enter 0 for MINIMUM 1 for NOMINAL and 2 for MAXIMUM East Track Tolerance Mode gt 0 West Track Tolerance Mode gt 2 DC TRANSIT VS NORMAL MODE The Genrakode specification allows for two different DC modes Transit and Normal In order to enable changing of this mode without requiring the us
8. 5 5 GND GND Figure 4 1 Serial Cable Pinout Like PGK the connection speed is 1200 bits per second baud and the connection parameters are 8 data bits no parity 1 stop bit and no flow control Upon powering up the test unit a message will be displayed from the boot loader as it performs a quick RAM check and some other power up self tests Any problems are reported via the serial interface Assuming all tests pass the unit will then prompt the user to press Enter to go into P2160TU Rev Sept 02 6 ALSTOM Signaling Inc the bootloader monitor or wait a few seconds to enter the test unit s serial interface The bootloader monitor is used in the flash upgrade process see Appendix A After entering the serial interface a GTU gt prompt will be displayed see Figure 4 2 below The user interface is similar to that of PGK The following commands are available type Enter for Command Summary GTU gt GTU Command Summary DCM Display Modify DC Mode Normal or Transit TOL Display Modify Tolerance Mode Minimum Nominal or Maximum TID Display Modify Code T Location ID MTS Display Modify Code T Enable Settings TCD Display Modify Code T to be Transmitted TPL Display Modify Code T Number of Parameters per Location CHK Display the Checksum and CRC of the System Flash Figure 4 2 also shows an example of the startup messages that in addition to the 14 segment LEDs
9. AC codes are Code 1 through Code 28 The test unit will ignore code selections as the switch is being turned unless there is a long enough pause on an intermediary selection e Code T toggles transmission of the trouble code This switch is only effective if Code T mode is enabled via the serial interface see section Code T below If enabled when this switch is turned on Code T will be transmitted using the location ID and trouble code as set via the serial interface When the switch is then turned off the test unit will complete the active Code T transmission and then stop So to send only one Code T flip the switch on and then off again e Code 5 6 this switch is a three position switch that toggles transmission of Code 5 or Code 6 As these codes are mutually exclusive both can not be transmitted simultaneously Per the Genrakode specification when Code 6 is selected only one Code 6 pulse will be sent followed by Code 1 The current Code 5 setting will be held over for about one cycle when the switch is flipped to Code 6 so a quick flip to Code 6 and then back to Code 5 will ensure that one Code 6 pulse is sent without disturbing the Code 5 transmission e Transmit Enable as its name implies this switch enables transmissions from the test unit Because this switch is interfaced directly to the analog transmitter circuitry within the unit the transmit LED will continue to blink when the unit would normally transmit However
10. ALSTOM Genrakode Test Unit User s Manual Features 6 Functionality Operation P2160TU Rev Sept 2002 ALSTOM Genrakode Test Unit User s Manual O 2002 ALSTOM Signaling Inc Features 6 Functionality Operation P2160TU Rev Sept 2002 Date Description TP amp T Rep Project Manager Project Engineer Mo Year _ Name Date _Name Date August 2001 Initial Release RIH 08 10 01 HWM 08 10 01 July 2002 Reflects Hardware Software JR RIH 07 01 02 HWM 07 01 02 Changes September 2002 Various Clarifications RIH HWM TABLE OF CONTENTS SECTION 1 INTRODUCTION 2 PURPOSE coil liada linia ste nda 2 SYSTEMOVERVIEW nseries 7 2 Figure del Genrakode Test Ulltoaiican iaa dai iaa 2 3 Figure 2 1 Layout of Test Unit Console ov sveocsoeszstcvet ian ocsedsiateied eseated A eveveley 3 4 7 SECTION SECTION 4 USING 5 SETUP E E dina 5 POWER UP SEQUENCE a a r e E A A E A EEA ste Ne 5 SERIAL INTERFACE ziea EE A EA E E E a TEES 6 Figure 4 1 Serial Cable Pi ol A A E hr E OAE RER 6 Figure 4 2 Startup Diagnostic Messages and GTU Prompt 7 TRANSMITTING AND RECEIVING Seea eaea SKE EEEE EA a e Teas 8 DE TRANSLE VS NORMAL MODE sereni A A E E a ei 9 CODE Biar 9 DISCONNECTING e ipren 7 12 APPENDIX A FLASH UPGRADING cccsccsssssscccseccrecsseceeesseesssessevsseesseesceesseesceescee
11. ads to a 9 to 16 Volt DC power source The nominal input voltage is 12 VDC The power source must be able to supply 3A of DC current If the test unit is to be used in AC mode and a separate power supply is being used to power the test unit from the one powering the module under test the ground connections from the two power supplies must be connected The next step is to connect the track leads to the Genrakode module under test First disconnect any track connections to the Genrakode module including any connections to Track Interface modules It should be noted that if only one track of the module under test is to be tested both sets of track leads need not be connected to the module If the module to be tested is operating in AC electrified Genrakode mode the West track leads of the test unit must be connected to the East track posts of the Genrakode module and the East track leads of the test unit must be connected to the West track posts of the Genrakode module This necessity is due to slight variations in the synchronization methods for the West and East tracks in AC mode If the module to be tested uses a Line Driver Converter Receiver board to interface to line wire it may be necessary to move the transmit tap settings on the Line Driver board to the 3 0V or 4 0V taps for the test unit to receive properly The test unit will not be damaged at any tap setting but proper reception of codes may require reducing the transmit voltage
12. e of the serial interface a special method of toggling between normal and transit mode was established To toggle the DC mode turn the unit off set the Code 5 type switch to the F1 position and turn the unit back on The DC mode will be toggled Once the unit has powered up the Code 5 type switch should be returned to its desired position It should be noted that the DC mode can also be changed via the serial interface s DCM command if desired Enter for Command Summary GTU gt dcm DC Mode NORMAL lt lt Modify DC Mode Settings gt gt Enter 0 for NORMAL 1 for TRANSIT Enter DC Mode gt 1 CODE T The Code T specification allows for transmission of a trouble code and location ID to simulate a problem at a given Genrakode location The test unit fully supports transmission and receiving of all possible Code T location IDs 1 through 27 and trouble codes 1 through 8 Note As a default the number of Code T parameters per location is set to 8 but to change this to 4 to match an earlier PGK application see instructions on the TPL command below P2160TU Rev Sept 02 9 ALSTOM Signaling Inc In order to receive or transmit Code T signals Code T must first be enabled via the serial interface The Code T enable setting is a per track setting that is Code T can be in one direction and disabled in the other P2160TU Rev Sept 02 10 ALSTOM Signaling Inc The command to enable or disable Code T is MTS
13. est Tnit Copyright ALSTOM 2 Eyri El Version Bel 2 00 ETC 06 14 2003 Syri 59 hoka Fiti Ted Lea HE Ale Seabee EN A 2431 ime ead mai 77 77 HUM Figure A 4 Downloading Hex File If you would like to confirm that the new software has been successfully programmed reenter the download application s terminal view by going to Actions gt Terminal Mode and power cycle the test unit You should see a new version number reflected in the system software the bootloader version number will remain the same Once the process is complete exit from the download application and power cycle the test unit P2160TU Rev Sept 02 15 ALSTOM Signaling Inc
14. he test unit features two simultaneously operating channels East and West While both channels are independent from each other certain settings must remain the same between the two channels Specifically the AC DC mode selection the Code 5 type and the DC Normal vs Transit selection must be the same for both transmit and receive on both channels As can be seen from Figure 2 1 the right side of the control panel is essentially a mirror of the left Both sides feature a two digit 14 segment display and Code 5 LED that indicate the code currently being received if any Additionally both sides contain a code select rotary switch a Code T transmit enable switch a Code 5 6 transmit switch and a transmit enable switch See the Transmitting and Receiving Codes section for descriptions of how to use these switches The test unit features over voltage current and thermal protection For example accidental connection of the track leads to a 16 Volt DC battery source will not damage the device Connecting the power connection or track leads backwards i e negative to positive and vise versa will also not result in damage to the unit While the device contains numerous such protections the maximum voltage that may be applied to any part of the device without causing damage is 16 VDC P2160TU Rev Sept 02 4 ALSTOM Signaling Inc SECTION 4 USING THE TEST UNIT SETUP The first step to begin using the test unit is to connect the power le
15. in a reset loop with P UP displayed on the 14 segment LEDs The system software may be reprogrammed via the test unit s serial connection The PGK Dloadwin downloading software and a system software image file are required and are available from ALSTOM Signaling Inc See below Flash Upgrading for full details on the reprogramming procedure After the unit has successfully completed its power up sequence it will immediately begin to synchronize both tracks with the module under test After synchronization occurs the test unit will automatically transmit and decode signals based on the current switch settings If the AC DC switch is not yet in its proper setting place it in its proper position now The AC DC switch position and any other switch position on the test unit may be changed at any time without needing to reboot or power cycle the device SERIAL INTERFACE The Genrakode Test Unit features a serial interface that can be used for a multitude of purposes including upgrading the system software running advanced diagnostics and changing several nonvolatile configuration settings The test unit is configured to be used with a laptop or personal computer connected via a DB 9 null modem serial cable or a straight through cable with a null modem adapter See Figure 4 1 below for the pinout This is the same cable used to connect a computer to the Programmable Genrakode CPU board 2 3 RX TX 3 2 TX RX
16. sceescesscessessscesscesseesseees 13 Figure A 1 Entering Monitor Mode to Prepare for Download ss 13 14 Figure A 3 Dloadwin in Test Unit mode Choosing File to Download ss 14 Figure 4 4 Downloading Hex Files tentes ani ath en eed eee 15 P2160TU Rev 2 1 ALSTOM Signaling Inc SECTION 1 INTRODUCTION PURPOSE The purpose of this document is to identify the functionality and use of the Genrakode Test Unit the test unit This document explains what the test unit is and how to use it SYSTEM OVERVIEW As its name implies the purpose of the test unit is to provide a device with which to test Genrakode or Genrakode compatible systems The test unit is compatible with conventional programmable PGK and electrified Genrakode systems as well as Harmon Industries Electrocode systems Additionally the test unit fully supports the PGK Code T implementation The test unit is upgradable via flash memory and thus can support future enhancements or changes that may be made to the Genrakode specification as well as features that may be added to the test unit system software Figure 1 1 Genrakode Test Unit P2160TU Rev Sept 02 2 ALSTOM Signaling Inc SECTION 2 TEST UNIT FEATURES The following are the test unit s most significant features Rugged design housed in a protective case and operates from 20 to 70 Celsius Portable lightweight and easy to transport Ease of use user friendly in
17. tuitive console Wide power voltage range 9 16 VDC RS232 communications port for connection to terminal or computer Flash Upgradability of system software Configuration settings are stored in non volatile memory The following diagram depicts the console of the test unit showing all switches LED displays and connections Qu TRACK ALSTOM eel O 5 GENRAKODE TEST UNIT D O CODE 5 POWER CODE 5 O 12VDC POWER O O Y Y OFF CODE CODE RECEIVED RECEIVED 3 72 48 2 72 43 A 7 ge 7 ga 4 4 Or Os 2 D 32 2 Daz 1 1 E 28 28 WEST EAST TRANSMIT LNG Fi TRANSMIT CODE T OFF CODE ALT F2 CODE CODET OFF STD E F3 OFF ee OFF CODE 5 CODE 6 TYPE CODE 5 CODE 6 TRANSMIT TRANSMIT ENABLE ENABLE CONNECT TO OFF oc ac opr CONNECT TO EASTTRACK DO TRACK CIRCUIT TYPE S WEST TRACK TX RX EAST 0 Figure 2 1 Layout of Test Unit Console P2160TU Rev Sept 02 ALSTOM Signaling Inc SECTION 3 GENERAL FUNCTIONALITY The Genrakode Test Unit was engineered with three primary design goals in mind portability functionality and upgradability The test unit is compatible with all existing Genrakode and Genrakode compatible systems to date including various competitors products The unit is capable of receiving DC track codes 1 through 9 and also features support for possible future codes AC codes 1 through 8 72 43 42 48 32 and 28 are also supported T

Download Pdf Manuals

image

Related Search

Related Contents

Western Digital AC2540 Computer Drive User Manual  Fujitsu Stylistic Q552 Getting Started Guide  Project D Autura 1000 - Instruction Manual v1.04  MANUAL DEL USUARIO - USER`S GUIDE    Téléport - Manuel d`installation  Windy City Gift Show - Grand Strand Gift & Resort  CAtAlogue des Ateliers-lAborAtoires - IDEFI  V_EKE 30_i.fm - Jungheinrich    