Home

User Manual & Installation Guide

image

Contents

1. IN TRON THE INDUSTRIAL NETWORK COMPANY 102MC Industrial Media Converter User Manual amp Installation Guide Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net IN TRON THE INDUSTRIAL NETWORK COMPANY Industrial Media Converter Installation Guide 102MC The 102MC is a 2 port unmanaged transparent media converter that converts 10Base T copper to 10Base FL half duplex fiber Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Copyright N TRON Corp 2008 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp is prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits a
2. ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary
3. depending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Delaware U S A Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net
4. ed to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets can be supplied with optional plastic brackets if isolation is required __ NONMETALLIC DIN RAIL Both V legs of the power input connector are connected to ANA chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as shown here Pe OONA EEE will ground the switch and the chassis The power leads from SWITCH CHASSIS TO the power source should be limited to 3 meters or less in POINT length As an alternate users can run a drain wire amp lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the penetration of the outer skin by less than 1 4 in Failure to do so may cause irreversible damage to the internal components of the switch Note Before applying power to the grounded switch you must use a volt DRAIN WIRE WITH LUGS meter to verify there is no voltage difference between the power supply s aE TO ONN negative output terminal and the switch chassis grounding point GROUNDING POINT METALLIC DIN RAIL MOUNT If the use of shielded cables is required it is generally recommended to only connect the shield at one end to pre
5. eriod whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may no
6. hing else to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to ground the unit WARNING Do not work on equipment or cables during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty WARNING Explosion hazard Substitution of components may impair suitability for Class I Division 2 WARNING Explosion hazard do not disconnect while circuit is live unless area is known to be non hazardous WARNING Explosion hazard do not replace the device unless power has been switched off or the area is known to be non hazardous Use 60 75 C rated Copper wire 0 22Nm 2 inch lbs Tightening torque for field installed conductors Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net PACKAGE CONTENTS Please make sure the Serial over Ethernet package contains the following items l 102MC Media Converter 2 Product CD Contact your carrier if any items are damaged INSTALLATION Read the following warning before beginning the installation WARNING Never install or work on elec
7. or better twisted pair cable into the RJ45 connector Connect the other end to the far end device Verify that the LNK LED s are ON once both the fiber and the copper are linked The MDIX mode of the 102MC can be changed using jumper J3 on the board By factory default the device is set up to use a straight through cable for a PC Any N Tron switch will automatically determine what MDIX the 102MC 1s using and will connect it to the network Warning Creating a port to port connection on the same switch 1 e loop is an illegal operation and will create a broadcast storm which will crash the network nd A Le e e e e oO Oo OO ee 0 O ia aooo 31 O o oo0 0 a ae O Oj D4 l l Note The 102MC is a transparent media converter Both the fiber port and the copper port must be linked in order for the unit to display any link status on the link LEDs At least one of the two ports must be hard set to 10Base if the fiber device is 10Base FL then it is automatically set to 10Base TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the version chosen Note The Inrush current will exceed the steady state current by 2X 3 Verify that Link LED s are ON for both ports 4 Verify cabling used between stations 5 Verify that cabling is Category 3 or greater for 10Mbit Operation 6 The 102MC is a transparent media con
8. p at an approximate 15 upward angle to completely remove the unit With the exception of the 524TX and 526FX2 all N Tron products are designed to be mounted on industry standard 35mm DIN Rail However DIN Rail mounting may not be suitable for all applications We offer 300 PM 900 PM three alternative mounting solutions Our 300 Panel Mount Assembly P N 300 PM may be used to mount a single 100 or 300 Series unit to a panel or other flat surface Our 900 Panel Mount Assembly P N 900 PM may be used to securely mount our 100 200 300 400 500 or 900 Series products to a panel or other flat surface Our Universal Rack Mount Kit P N URMK may be used to mount our products to standard 19 racks URMK Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net FRONT PANEL From Top to Bottom Green LED lights when Power is connected RJ45 Port 10Base T Connection ACT Activity LED for Fiber Optic Port LNK Link LED for Fiber Optic Port RX Fiber Optic Receiver Port TX Fiber Optic Transmitter Port NOTE The RJ45 data port has two LED s located at the left side of the connector The top LED indicates Activity ACT and the lower LED indicates Link LNK status LED s The table below describes the operating modes ly GREEN Power 1s Applied OFF Power 1s OFF GREEN 10 Mb Link between ports S OFF No Link between ports GREEN Data is active between por
9. rising out of errors or omissions 1n this manual or the information contained herein Warning Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit Do not operate the unit with the top cover removed as this could create a shock or fire hazard Do not block the air vents on the sides or the top of the unit Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard Do not operate the equipment in a manner not specified by this manual SAFETY WARNINGS General Safety WARNING Ifthe equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired Contact Information N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL 251 342 2164 FAX 251 342 6353 Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net ENVIRONMENTAL SAFETY AX WARNING Disconnect the power and allow to cool 5 minutes before touching ELECTRICAL SAFETY 1995 NCS ine Wo 60140450 AN 1905 HCS ine Wo 0 100 450 WARNING Disconnect the power cable before removing the enclosure top WARNING Do not operate the unit with the top cover removed WARNING Properly ground the unit before connecting anyt
10. t be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY
11. trical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present 1965 HCS ine Wo 100480 Disconnect the power cable before removing the enclosure top Do not operate the unit with the top cover removed UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth SERVICING Jumper J3 can be changed on the board to change the RJ45 copper port s MDIX setting See Connecting the Unit on page 8 for more details Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net DIN Rail Mounting Install the unit on a standard 35mm DIN Rail Recess the unit to allow at least 5 of horizontal clearance for the fiber optic cable bend radius To install the unit to 35mm industrial DIN Rail place To remove the unit from the 35mm industrial DIN Rail the top edge of the included mounting bracket on the back place a flat head screwdriver into the orange release clip of the unit against the DIN Rail at a 15 angle as shown found at the bottom of the unit and apply downward force Rotate the bottom of the unit to the back away from you on the clip until it disengages from the bottom of the unit until it snaps into place from the DIN Rail Rotate the bottom of the unit towards you and u
12. ts OFF Data is inactive between ports Revised 2010 11 15 7 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net APPLYING POWER Top View EES EE A se ere COCs T T O E IO OOO T TONN Vit Vie Vt y SELAA Unscrew amp Remove the DC Voltage Input Plug from the Power Input Header Install the DC Power Cables into the Plug observing polarity Plug the Voltage Input Plug back into the Power Input Header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot Verify the Power LED stays ON GREEN Note Only 1 power supply must be connected to power for minimal operation For redundant power operation V and V2 inputs must be connected to separate DC Voltage sources This device will draw current from both sources simultaneously Use 16 28 gauge wire when connecting to the power supply Recommended 24V DC Power Supplies similar to LOOVAC 240VAC N Tron s NTPS 24 1 3 DC 24V 1 3A Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net N TRON SWITCH GROUNDING TECHNIQUES The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best noise immunity and emissions 1 e CE are obtained when the N Tron switch chassis is connect
13. urs gt Cat3 Cable 50 125 um Fiber 850nm 62 5 125 um Fiber 850nm 100 140 um and 200 um Fiber 850nm One 1 RJ 45 Copper Port SC or ST Duplex Port Recommended Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Emissions and Safety Approvals FCC Part 15 Class A Suitable for use in Class Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only Warranty Effective January 1 2008 all N TRON products carry a 3 year limited warranty from the date of purchase Revised 2010 11 15 13 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty p
14. vent ground loops and interfere with low level signals i e thermocouples RTD etc Cat5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches METALLIC NONMETALLIC a T SHIELDED PATCH CABLE nE STP CIT m LEE STP 2 e Note Strain relief boots not shown for clarity purposes In the event all CatSe patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Revised 2010 11 15 9 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications 0 232 0 005 5 990 127 CAT5e CABLE EIA 568B 0 237 0 005 6 02 0 1 3 CATSe CABLE Revised 2010 11 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CONNECTING THE UNIT For the 10Base FL Fiber Optic port remove both of the dust caps from the fiber optic connectors and connect the fiber optic cables The TX port on the local unit should be connected to the RX port of the far end device and the RX port should be connected to the TX port of the far end device For 10Base T port plug a Category 3
15. verter 1f one side isn t linked properly both ports will not indicate a valid link Revised 2010 11 15 11 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net SUPPORT Contact N TRON Corp at TEL 251 342 2164 FAX 251 342 6353 FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation Revised 2010 11 15 12 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Physical Height Width Depth Weight DIN Rail Electrical Redundant Input Voltage Inout Current Inrush Current Input Ripple Inout Wire Size Environmental Operating Temp Storage Temp Operating Humidity Operating Altitude Shock and Vibration Shock Vibration Seismic KEY SPECIFICATIONS 3 49 2 01 4 00 0 75 lbs 35mm 10 30 VDC Regulated 80 mA 24VDC Steady State 7 3Amp 1 0ms 24VDC Less than 100 mV 16 28 AWG 40 C to 80 C 400C to 85 C 10 to 90 Non Condensing O to 10 000 ft 200g 10ms 50g 5 200HZ Triaxial Note Unit must be Bulkhead mounted to achieve these levels Reliability MTBF Network Media 10BaseT 10BaseFL Connectors 10BaseT 10BaseFL gt 2Million Ho

Download Pdf Manuals

image

Related Search

Related Contents

平成27年10月1日 登録番号 史料名 部署等 ⑦教育-全般  エアーコンプレッサー  PROGRAMME DE FORMATION ATTESTATION D  Haier 50FREE-3B Washer User Manual  LG Electronics LF-U850 Stereo System User Manual  Samsung Samsung GALAXY  PDFファイル - 医薬品医療機器総合機構  D2 AMG Mercedes CLK  NRG Turbine Control Anemometer Digital, PNP, 8.0 m User Manual  VTech 1930c Cordless Telephone User Manual  