2-WIRED VIDEO DOOR PHONE —4” TFT INDOOR MONITOR
Contents
1. 1 Volume adjustment E401C T Ss i Ring volume adjustment E400C T connection m 2 Chrominance adjustment terminal Ss 3 Brightness adjustment ae eee Zt button area Handset Monitor button no bother LED TO Unlock Ring select button Intercom button B Talk amp Power button LED Notice 1 Key functions of E400C T with handset have no difference with E401C T except talk button 2 Under operation please press the centre of button as the above picture indicate 3 Monitoring outdoor unit Under standby status press button to monitor Door 1 Door 2 repeatedly pressing button you can circularly monitor outdoor Door 1 Door 2 Exit If only one outdoor unit is connected repeatedly pressing button you can circularly monitor door Door 1 Exit Remark Under monitor status the screen can be only displayed image without voice and cannot unlock the door 4 Talk Stop a Calling turns into talking In the status that outdoor unit calls indoor unit or indoor unit monitors outdoor unit for E400C T as soon as you pick up handset for E401C T only need to press g3 button you can talk with outdoor unit and meanwhile the corresponding outdoor unit s LED turn light the blue LED indicated Door 1 the green LED indicated Door 2 Monitoring turns into talking Indoor unit in the monitoring status you can pick up handset of t
2. times to choose monitor B s number Then press Z button to call monitor B For example Want to call monitor 3 you can press button until unlocking LED flashes then press g3 button to call monitor 3 Remark the LED flash indicate corresponding room number no bother LED green No 1 r Unlock LED green No 2 intercommunication LED green No 3 Z Door 2 LED green No 4 In the process of a amp b operations there is a waited time gap of 4 seconds to operate next step o when you press first time if within 4 seconds you don t press 1 button again you have to repeat the above operation 12 Outdoor unit call transferring suitable for multiple monitors When indoor and outdoor units under talking status you want to transfer the call to the other monitor the operation is same as intercommunication operation Under indoor and outdoor units talking status others will enter into busy status 17 Communication problem alarm suitable for multiple monitors If indoor unit sounds DI DI every 3 seconds which means the communication problem between indoor units Please check the circuit or whether main indoor unit has been closed After troubleshooting press or B to connect with outdoor unit the alarm will be automatically cancelled Only in the case that monitoring or talking function is been operated more than 6 times the indoor unit would sound the alarm 18 Switch of monitoring scene Outdoor c
3. Specification ee Model E400C T E401C T Display screen 4 color TFT Power supply AC110 240V 50Hz 60Hz 10W or DC13 5V 1 5A Connection In series Talk Handset E400C T series Hands free E401C T series Power consumption 13 5V 550mA max Optional ringtone Chord music and ding dong sound Color system Automatically switch Operation temperature 10 C to 55 C Optional indoor x IIS 2 wired indoor unit extension Optional outdoor unit IIS 2 wired outdoor unit TOP WAY INTELLIGENT SCIENCE amp TECHNOLOGY CO LTD Sino American Joint Venture www iis home com Content Product Introduction vrrrreeetrcceccc erent cece ttnt 2 Features and Parts etter enreee rane ie totem na cecemm ses anee cone sesepeememssneaseestoe szeemeese 3 Operation sea ea ee a ces eee S 4 Special function 22eeree ttti estes snc ences nec eesneec ee neeee etna etna 11 LED Voice statement 22 sseeeeeeeeeeeeeeseeeeeeetessteseeeeeessneeeeeseeetsneeeeeeesseeeees 13 Trouble shooting guide Anankan e eaae cee aeaea ae 14 Specification 41 1tt 141 t mememe emnene 15 First thank you for purchasing our intercom system before installing please read the instruction carefully and according to the direction correctly install and use it Please query your dealer for more information Feature and parts
4. amera CCTV camera When outdoor unit calls in press button you can see the CCTV image which connect on the outdoor camera Press the button again you can see the outdoor camera image When indoor unit is under monitoring or talking with outdoor camera long press button you will hear DI DI then the image would be switched to the CCTV image which connected on the outdoor camera 19 Open circuit alarm of outdoor unit Under standby status the indoor unit will continuously sound DI and LED will be flashed if the outdoor unit is open circuit The alarm will be automatically stopped after 10 times sound only left the corresponding LED to remind The indoor unit cannot automatically inspect the open circuit condition under talk and monitor status Remark LED indicated Door 1 a LED indicated Door 2 3 Automatically setting room number a While there is only one indoor unit as long as you connect with outdoor unit the settings of room number can be successful b While there are two indoor units you must first initialize indoor units then let outdoor unit call indoor unit You can close the call after two indoor units ringing and 2 3 seconds pass room number setting is succeed c While the quantity of indoor units is over 2pcs you must first initialize all indoor units then switch on the main indoor unit and another indoor unit which you prefer to set as No 2 then let outdoor unit call indoor unit You can clo
5. ant effect 16 Alarm caused by identical room number suitable for multiple monitors If in the system more than two indoor units have same room number the monitor will sound DI at intervals On this occasion you need to reset the room number in order to avoid conflict caused by the same room number If there is still alarms after reset you have to restart power supply Special function If not special circumstance please don t reset the room number under the circumstance that the system can normally run Misoperation will cause the system improper work 1 Initialization Under standby status long press the button and wait until it successively sound DI DI DI release the button the indoor unit will sound to remind successfully initialization If you don t relesae the button after three sound DI the indoor unit will sound DU means operation failed 2 Manually setting room number Under standby status press the button 3 seconds and wait till the indoor unit sound DI DI enter into room number manually setting The four LED indicate the corresponding room number main indoor unit indoor extension2 indoor extension3 G indoor extension 4 If no corresponding LED light on means no room number exist While setting room number you can switch to the relevant room number per pressing the button meanwhile the corresponding LED will light after that you must press the button to sav
6. e up to 10 seconds Remark Equipping the outdoor unit with the electronic lock you can realize unlocking function 6 Ringtone selection Press and hold button o you ll hear the current ringtone The ringtone can be changed per pressing o button Press g3 button to exit or you can wait 30 seconds up to automatic exit Remark As default the selected ringtone will be automatically assigned to Door 1 the next ringtone after it will be assigned to Door 2 7 Ringtone volume adjustment for E401C T In the process of ringtone selection the ringtone volume will switch between the first level and fourth level per pressing button meanwhile the corresponding LED will twinkle Remark No bother LED green The first level Intercommunication call LED green The second level T Unlock LED green The third level Door 2 LED green The fourth level 8 No bother function settings Under standby status press and hold button till it sounds DI meanwhile LED turns light 6 no bother setting succeed Under standby status press and hold button till it sounds DI DI meanwhile LED turns off to quit no bother setting succeed Remark LED indicate no bother LED 9 2nd door calling function optional 1 The display screen in the status of shutting down display if you press the 2nd door button the indoor unit will ring 2 The display screen in the status of long light if you press the 2nd door button no bother LED f
7. e your settings Remark 1 The system will exit from the setting status if there isn t any operation within ten seconds 2 Main indoor unit cannot set the room number LED Voice statement 1 LED statement LED lights red Q LED lights green The indoor unit in the status of power on The indoor unit in mute status no bother state LED flashes green The second door call LED flashes green Door 1 in open circuit status TOLED flashes green Door 2 in open circuit status LED flashes blue Door 1 call Z LED flashes green Door 2 call The other outdoor unit call Indoor unit in standby status Z LED alternately flashes blue green Four green lights in the panel all light 2 Voice indication statements 1 DI at intervals means same room number in two indoor units DI DI at intervals means indoor unit has communication problem DU means the function is forbidden Long DI means the indoor unit is switched on DI with LED flashes means Door 1 open circuit oa KR wWhND DI with LED flashes means Door 2 open circuit 11 Intercommunication suitable for multiple monitors a If system connect two indoor units under standby status pressing button and waiting until hearing DI then pressing button you can immediately call the other indoor unit If system connect more than two indoor units monitor A want to call monitor B press button in multiple
8. he indoor unit E400C T for E401C T only need to press the button g3 to enter into talk status Standby status turns into talking The system only connect with one outdoor unit press g3 button the screen will show the outdoor image talk with outdoor directly for E401C T Remark Using E400C T you still need to pick up the handset to be able to talk with outdoor unit o e Q Hang up Under talk status hang up the handset to exit the status for E400C T or press 3 button to exit for E401C T You can also wait 90 seconds up to automatic exit and that power LED lights IIS 2 WIRED VIDEO DOOR PHONE 4 TFT INDOOR MONITOR C1 E400C T C E401C T n 090 80 SE CE FE amp R amp TTE RoHS ISO9001 IS014001 OHSAS18001 Products Introduction General features z Kinds of chord ringtones optional Support multiple indoor monitors gt Four levels ring adjustable max to 4pcs monitor z Outdoor monitoring remote unlocking gt Pedal control for talk 2nd door call Chrominance and brightness adjustable function optional 7 No bother mute function CAUTION To avoid the risk of electric shock please don t remove cover or back Please ask professional person if maintenance needed Remind users that important operation and maintenance guide are included in the attached user s manual Remark TIS reserves the right to change or modify designs and spec
9. ifications without any prior notice for the improvement and promotion of products quality Please refer to the real products 12101701 Operation 1 ON OFF a After the intercom is connected with the power supply the red LED of the button G will always keep lighting means the intercom turns into standby status The intercom in power off status press g3 button and wait until hearing DI means the intercom turns into standby status b The intercom in standby status press and hold button till hearing DI DI meanwhile the B power LED turns off means the intercom turns into off status Blue LED indicate for Door 1 2 Outdoor unit call remind g a a When outdoor unit calls in the indoor unit s screen will display the image meanwhile the blue or green LED flashes and sounds the ring No Green LED indicate for Door 2 ringing under no bother status Remark B blue LED indicate Door 1 green LED indicate Door 2 b Indoor unit and outdoor unit under talk status if the other outdoor unit calls the corresponding LED would be alternately flashes 8 times but no ringing at this moment 5 Unlock Under talk status press to unlock the door The default of unlocking time is three seconds If you press and hold button indoor unit will be always in unlocking status the longest extended time can b
10. lash but no ringing The ring or flashing LED will be turned off after 8 seconds 2 Ji i Outdoor calling 2nd door calling 10 Pedal control for talk function optional If system connected with two outdoor units and under standby status while pressing the pedal control switch in multiple times you can circularly monitor outdoor Door 1 Door 2 Exit If only one outdoor unit is connected repeatedly pressing the switch you can circularly monitor outdoor Door 1 Exit Remark The function is default to be closed under factory setting 13 Busy status a When one monitor is under talking or monitoring status other monitors will enter into busy status b When two monitors are under talking status other monitors will enter into busy status After finish talking all the monitors will back to standby status 14 Talking volume adjustment E401C T During talking adjust the volume adjustment switch to change the indoor unit s talking volume E400C T During calling adjust the volume adjustment switch to change the ring volume as well as the button volume 1 Volume adjustment E401C T Ring volume adjustment E400C T 2 Chrominance adjustment 3 Brightness adjustment 00000 0800 00000 15 Chrominance brightness adjustment In the process of turning on the screen to adjust chrominance and brightness switch can change the relev
11. roubleshoot the wiring between the problem indoor unit and main indoor unit There are two indoor units with the same room number Indoor unit continuously sound DI if multi indoor units Reset the room number referring to the second item Manually setting room number in the special function Outdoor unit cannot call indoor unit The main indoor unit is under the status of cannot monitor outdoor unit and power off sound DI D at intervals Reference to operation item 1 ON OFF Outdoor unit can hear the voice of indoor unit but the outdoor unit voice heard by indoor unit is smaller than normal for E401C T Outdoor unit cannot call and indoor unit and the indoor cannot monitor or talk when there is only one indoor unit Smaller talking volume Referring to talking volume adjustment adjust the volume to the relevant position The wiring between the indoor unit and outdoor unit disconnect Troubleshoot the connection wiring between indoor unit and outdoor unit
12. se the call after two indoor units ring and 2 3 seconds pass switch on the other indoor unit which you prefer to set as No 3 and let outdoor unit call indoor unit You can close the call after indoor units ring and 2 3 seconds pass Same operation for the No 4 indoor unit Trouble shooting guide Problem Possible cause Solution The unit is not connected with power supply 1 Check whether the power supply adaptor or AC power supply cable is good inserted into ati the socket The unit is under the status of power off 2 Reference to operation item 1 ON OFF The unit is no reaction N Check whether the connection of outdoor unit with indoor unit is disconnected Reference to operation item 1 ON OFF The connection of outdoor unit with indoor unit disconnect The main indoor unit is under the status of power off Outdoor unit could not call N m Cannot monitor outdoor unit Room number haven t been set Reset the room number referring to the second item Manually setting room number in the special function Troubleshoot the wiring between indoor unit and outdoor unit N 2 The connection of outdoor unit with indoor unit disconnect Indoor unit discontinuously sound DI The main indoor unit is under power off if multi indoor units status The wire which connect with the main indoor unit is disconnected Reference to operation item 1 ON OFF N N T
Download Pdf Manuals
Related Search
Related Contents
ChromaBlast-R Driver User`s Manual 2100-Alpha 2100-Beta Tecra a10 - TOSHIBA FORUMS Philips Drip tray HD5203 SIMOVERT P Transistorised Voltage–Source DC–Link Inverters Samsung LE23R41B Εγχειρίδιο χρήσης GRAFIK Eye パワーインターフェース KOHLER K-2497-F39 Installation Guide COUVERTURE ANTI-FEU GRAND FORMAT USER`S MANUAL Copyright © All rights reserved.