Home
Laurel High Performance DPMs
Contents
1. 1200A Mechanical AE 2130 84 PowerPad Jr Model 8230 w 24 AmpFlex 193 24 BK 6500A Communication Port Optically isolated USB AE 2130 85 PowerPad Jr Model 8230 w 36 AmpFlex 193 36 BK 6500A Display 1 4 VGA 320 x 240 color LCD AE 2130 86 PowerPad Jr Model 8230 w MR193 BK 1000AAC 1400ADC Dimensions 8 3 x 4 3 x 2 4 211 x 108 x 60mm AE 2130 87 PowerPad Jr Model 8230 w MN193 BK 6A 120AAC Safety Rating EN 61010 600V Cat III Pollution Degree 2 AEMC Power Quality Meter e Displays Min Max and Average Volts and e Displays F or C amp resistance to 2000Q Amps Crest Factor Peak value and K Factor e Conducts continuity and diode tests e Calculates and displays Watts VARs and VA e Stores up to nine complete sets of readings Power Factor and Displacement Power Factor for all volt amp power harmonics and other for single phase and balanced three phase measurements e Displays total harmonic distortion THD F and e Configurable from DataView software or THD R for voltage and current front panel 7 e Displays individual harmonic values and for e Operates off batteries or optional AC adapter F Volts and Amps through the 50th harmonic e Includes DataView software for data ie e Captures and displays inrush current storage real time waveform display analysis a e Calculates amp displays phase rotation amp RPM and report generation lead amp black connector black amp red 10 ft SPECIFICATIONS voltage leads and alligat
2. Programmable from 125mS to 1 day 600V Voltage Channel Banana jacks O to BOOVAC DC Input Connection Input Range 0 1V 5 50V 0 5 of Rdg 1V 50 600V 0 5 of Rdg 0 5V 1000V Resolution Accuracy 50 60Hz Measurement Input CAT Ill Rating SPECIFICATIONS Memory 240 000 measurements 512KB Recording 15 minutes to 8 weeks programmable using Length DataView Storage Modes Start Stop FIFO and Extended Recording Mode XRM Communication USB 2 0 optically isolated Power 2 x 1 5V AA cell Alkaline batteries Battery Life 100 hrs to gt 45 days depending on storage rate Dimensions 5 38 x 2 75 x 1 28 136 x 70 x 32mm Temperature 10 to 50 C operating ORDERING INFORMATION AE 2126 02 Simple Logger II Model L101 TRMS O to 1VAC 1 channel AE 2126 03 Simple Logger II Model L102 TRMS O to 1VAC 2 channel AE 2126 04 Simple Logger Il Model L111 TRMS O to 1AAC 1 channel AE 2126 05 Simple Logger II Model L261 TRMS O to GOOVAC DC 1 channel AE 2126 06 Simple Logger II Model L322 4 20mA DC AE 2126 07 Simple Logger II Model L432 100mV 1V 10VDC 2 channel AE 2126 35 Simple Logger II Model L562 TRMS Voltage amp Current AE 2126 08 Simple Logger II Model L642 Thermocouple Temperature AE 2126 01 Simple Logger II Model CL601 Clamp On TRMS Current O to 600A 1 65 jaw opening AE 1201 51 AE 2115 82 AE 1200 72 AE 1200 73 AC DC Current Probe Model SL261 10A 100mV A
3. 10 data Energy discharge Automatic discharge after measurement Display LCD Digital and bargraph display with backlight Display Info Time date test voltage timer battery level PC software For USB data transfer and report editing Power supply 6 AA batteries Standards CAT IV 600V CAT III 1000V Dimensions 10 2 Wx9 9 H x 4 7 D 260 x 251 x 119mm Fluke MegOhmMeters Handheld MegOhmMeter e Insulation resistance to 10GQ 1507 e Test voltages to LOOOV e Calculates Polarization Index amp Dielectric Absorption Ratio 1507 e AC DC voltage measure to GOOV e Pass Fail function for repetitive tests 1507 e Remote probe for hard to reach tests SPECIFICATIONS Insulation Resistance lt d 1507 Ranges 0 01 MQ to 10GQ 1507 0 01 MQ to 4000 MQ 1503 Test Current 1mA max Test Voltage 50 100 250 500 1000 V 500 amp 1000 V on 1503 Basic Accuracy 1 5 rdg 5d up to 2000 MQ Resistance 0 01 to 20 00 kQ Basic Accuracy 1 5 rdg 3d Voltage 0 600 0 V DC or AC 50 400Hz Live Circuit Indicator Inhibits insulation resistance test if gt 30V AC DC present Operating Temperature 20 to 55 C Rating CATIV 600V Includes test leads test probes alligator clips protective holster amp batteries ORDERING INFORMATION Fluke 1503 1kV Handheld Insulation Resistance Tester Fluke 1507 Deluxe 1kV Handheld Insulation Resitance Tester Fluke 1550B 5kV MegOhmMeter WESCHLER IX SHENS LISI e Insulation
4. 100A 10mV A BNC AC Current Probe Model MN261 24A 100mV A 240A 10mV A BNC AC Current Probe Model MR461 GOA 10mV A 600A 1mV A BNC AC Current Probe Model MR561 150A 10mV A 1500A 1mV A BNC AE 2113 49 AC Current Probe Model SR661 10A 100mV A 100A 10mV A 1000A 1mV A BNC AE 2110 90 AC Current Probe Model JM861 30A 10mV A 300A 1mV A 3000A 0 1mV A BNC AE 2140 62 Test Lead Pair 5 ftw alligator clips 6OOV CAT IV 15A Recessed banana jacks 0 1A AC probe dependent 0 5 of Rdg 1mA 0 5 of Rdg 0 5mV L322 L432 One Two Removeable screw term block 20mA DC 100mV 1V 10V 0 01mA 0 1mV 1mV 10mV 0 25 of 0 5 of Rdg 1mV Rdg 0 05mA One 0 600V AC DC 0 1V 5 50V 0 5 of Rdg 1V 50 600V 0 5 of Rdg 0 5mV Max 8 samples at storage interval 300V 50V L642 Two Mini TC F C 346 to 2192 210 to 1200 328 to 2501 200 to 1372 418 to 752 250 to 400 328 to 2372 200 to 1300 238 to 1742 150 to 950 32 to 3212 0 to 1767 32 to 3212 0 to 1767 0 1 C F up to 1000 C F 1 above 1000 C F 0 1 to 0 2 0 6 to 1 depending on the range amp T C type 8 samples at storage interval Programmable from 5 sec to 1 day 50V MODEL Channels Input Connection Measurement Range Resolution Accuracy Sample Rate Max Storage Rate CAT Ill Rating s439907 VIVG suaquooay CLAMP ON AC LOGGER Simply clamp on and start recording no exposed w
5. 4 4 C PAXCDS10 Dual Form C Setpoint Relays 5 A 240 VAC or 28 VDC res TC Type N 200 to 1300 C 13 C 3 1 C PAXCDS20 4 Form A Setpoint Relays 3 A 250 VAC or 30 VDC res TC Type C O to 2315 C 1 9 C 6 1 C PAXCDS30 4 Setpoint Sinking Open Collector Outputs 0 1A SOV _ RTD Input 2 3 or 4 wire sensor 10Q max lead res 3Q on Cu RTD PAXCDS40 4 Setpoint Sourcing Open Collector Outputs 0 1 A 30V Readout Cor F with 1 or 0 1 resolution PAXCDL10 Analog Output Card 0 20 4 20 mA 0 10 VDC Offset Range 19999 to 99999 digits PAXCDC10 RS485 Serial Communications Card with Terminal Block Totalizer 9 digit 0 001 to 65 000 scale factor 0 01 accuracy PAXCDC1C Extended RS485 Card with Dual RJ11 Connector A D Converter 16 bits 20 readings sec PAXCDC20 RS232 Serial Communications Card with Terminal Block Control Inputs Three jumper selectable sink source max input PAXCDC2C Extended RS232 Card with 9 Pin D Connector 80 VDC continuous not isolated to sensor input PAXCDC30 DeviceNet Communications Card AC Power 85 to 250 VAC 50 60 Hz 15 VA gt gt PAXCDC40 RS485 Modbus Communications Card LV Power 11 to 36 VDC 11 W 24 VAC 50 60 Hz 15VA PAXCDC4C Extended Modbus Card with Dual RJ11 Connector Input Isolation 2300 Vrms to AC power 500 Vrms to LV power PAXCDC50 Profibus DP Communications Card eT eee comm Sanat et _____ A g g ee ee Temperature O to 50 C operating lt 85 RH non condensing add ASSY to
6. A B phase angle stopwatch batch counting VF1 4 20 mA VF2 0 1 mA VF3 0 10 V With main boards 5 amp 6 V to F converter for rate or square root of rate from differential pressure or target type flow meters With main boards T7 amp 8 Above plus rate and total simultaneously linearization of nonlinear inputs batch counting 1 rate time QD Quadrature With main boards 5 amp 6 Scalable to 999 999 for position from encoders QDR Quadrature Rate With main boards 7 amp 8 Scalable to 999 999 for position or rate from encoders CBLO1 RJ11 TO DBY Cable to PC Com port CBLO2 USB to DB9 Adapter CBLO5 USB Cable to PC USB Port Li WESCHLER 800 903 9870 fax 800 903 9590 weschler com info weschler com INST STRUMENTS Fluke Power Logger e Monitor demand at 15 minute or user defined averaging periods e Verify efficiency improvements with energy consumption tests e Measure harmonic distortion caused by electronic loads e Capture voltage dips and swells from load switching e Easily confirm instrument setup with color display of waveforms and trends e Measure all three phases and neutral with included 4 flexible current probes e View graphs and generate reports with included Power Log software e Compact rugged design with IP65 case 600 V CAT IIl and 2 year warranty The Fluke 1735 Power Logger is ideal for conducting 30 day load studies according to National Electric Code 220 65 The 1735 also logs most electrica
7. Log software optical USB cable color localization set Getting Started manual Users manual 434 Includes Hard carrying case four cur rent probes i400s five test leads and clips battery charger FlukeView software optical USB cable color localization set Getting Started manual Users manual 3 Year warranty The Fluke 435 and 434 three phase power quality analyzers help locate predict pre vent and troubleshoot problems in three phase and single phase power distribution systems The new IEC standards for flicker harmonics and power quality are built in e Analyzer trends using cursor amp zoom tools even while background recording e Seven hours operating time per charge on e Transfer data files to your PC for reporting and analysis using FlukeView software e Automatic transient capture never miss an event e Auto Trends don t waste time setting up recordings 1197uf i189u F 1990F 03v Feature Measure voltage current dips swells interruptions harmonics inter harmonics flicker power energy transients frequency unbalance inrush EN50160 overview e Logger function with multiple parameters e Optional Mains signalling e Optional Current probes 3000A flexible 4 40 400A clamp 4 Memory 16MB 8MB Software Power Log amp FlukeView FlukeView IEC61000 4 30 Class A compliance o e Safety rating CAT IV 600 V CAT III 1000 V Battery life Up to 7 hours charge Optional function ca
8. bits 0 0015 Environmental Operating temperature 0 55 C 95 RH at 40 C non condensing Data Communications opt Type USB RS 232 RS 485 2 or 4 wire Protocol Modbus RTU Modbus ASCII or Laurel ASCII CBLO1 RJ11 TO DBY Cable to PC Com port CBLO2 USB to DB9 Adapter CBLO5 USB Cable to PC USB Port ORDERING INFORMATION Example L10010DCV1 U Laureate Series L Laureate Panel Meter LW Laureate Weight Meter U Main Board 1 DPM with green LEDs 2 DPM with red LEDs 3 Extended green LEDs 4 Extended red LEDs Note Extended capability for DPMs is required for custom curve linearization U Power 0 85 264 Vac 90 370 Vdc 1 10 48Vdc 12 30 Vac LI Setpoint Output 0 None z0 1 Dual 8 A relays 72 2 Dual solid state relays oF U Analog Output 0 None 1 0 20 mA amp 0 10 V U Digital Interface 0 None 1 RS 232 Isolated 2 RS 485 Isolated 4 RS485 Modbus Isolated D USB 6 USB to RS 485 Converter U Input Type DC Volts DCV1 200 00 mV DCV2 2 0000 V DCV3 20 000V DCV4 200 00 V DCV5 600 0 V DC Amperes DCA1 2 0000 mA DCA2 20 000 mA DCA3 200 00 mA DCA4 5 000A Process Signals 4 20 mA 0 5 V etc P P1 Strain Gage Potentiometer 4 wire ratio SG 0 200 mV 0 20000 SG1 Custom Scaling _ Note The same DC signal conditioner board can be user configured for DC Volts DC Amps process or strain 4 20 mA 0 10000 Custom Scaling 100 Ohm Platinum RTDs P385C 202 to 850 C P385F 331 to 1562 F P392C 202 to 850 C P39
9. current probes measure from 0 5A to 1000A e Dual range 100 1000A e Programmable storage rates from 8 every second to 1 every day e 3 user selectable storage modes e Stores up to 240 000 measurements in non volatile memory e Lightweight compact fits anywhere e 5 LED indicators quickly and clearly display logger status SPECIFICATIONS AC Current 10 to 200A Inputs Two captive MiniFlex AC current flexible sensors AC Voltage 10 to 600V Range 0 5 to 100AAC 5 to 1000AAC Resolution 0 1A or 0 1V Resolution 0 1A Accuracy 2 rdg 1A 2 rdg 1V Basic Accuracy 1 of Reading 50 60Hz Memory 256 000 points Sample Rate 64 samples cycle Sampling Rate 1 second to 24 hours Storage Rate Programmable from 125ms to 1 day l PC Interface USB clades soaa Record Modes Start Stop FIFO and Extended Recording Mode XRM Record Length 15 minutes to 8 weeks programmable using DataView rower 3 6V Lithium battery Memory Non volatile storage of 240 000 measurements 512kB Dimensions 4 5 x 2 5 x 1 3 114 x 63 x 34mm Complete with two Current sensor modules two Voltage sensor mod ules two sets of test leads two sets of alligator clips USB cable Windows compatible software universal AC Adaptor 4 AAA batteries and two memory 2032 button batteries ORDERING INFORMATION EX DL160 Dual Input True RMS AC Voltage Current Datalogger 123 Communications Optically isolated USB 2 0 Protection IP40 Rating 600V CAT IV 10
10. display from a user input Time Accuracy 0 01 typical Decimal Point O to 0 0000 Scale Factor 0 001 to 65 000 Low Signal Cut out 19 999 to 99 999 Total 9 digits main display alternates between high order and low order readouts Custom Linearization Data Point Pairs Selectable from 2 to 16 Display Range 19 999 to 99 999 Decimal Point 0 to 0 0000 Compensation User value 0 00 to 650 00 uV C for ice point Memory Non volatile EZ2PROM memory retains all programmable parameters and display values User Inputs Two programmable user inputs Operating Temp 0 to 50 C 85 RH max non condensing O to 45 C with all three plug in cards installed Connections High compression cage clamp terminal block Case 1 8 DIN rated for NEMA 4X IP65 indoor use IP20 Touch safe Installation Category Il Pollution Degree 2 Construction Flame resistant one piece bezel case with synthetic rubber keypad en _________________ Dimensions 1 95 H x 3 80 W x 4 24 D_ 50x97x108mm 22d Excitation Power DIGITAL METERS WESCHLER 800 903 9870 fax 800 903 9590 weschler com info weschler com INS TRUMEN TS Laurel Programmable Counters FUNCTIONS e Rate Frequency Period e Batch Controller e Simultaneous Total amp Rate e Analog Totalizer e Time Interval Stopwatch e Phase Angle amp Power Factor e Quadrature Position or Rate e Duty Cycle e Ratio Draw FEATURES OPTIONS e 999 999 Display Span e Dual R
11. up to 1000V then 100V Leakage Current 1nA 2mA Capacitance 0 01 uF 15 00 uF Timer 0 99 minutes Power 12V rechargeable battery Charger 85 250VAC Operating Temperature 20 to 50 C Includes test leads SOOV probes alligator clips interface adapter amp cable FlukeView software line cord amp carrying case 154 INAWdINoF isa TEST EQUIPMENT VW ESCHLER 800 903 9870 fax 800 903 9590 weschler com info weschler com INSTRUMENTS Megger Insulation Resistance Testers MIT510 and MIT520 5kV Testers CED This new generation of insulation testers offers increased measurement range better accuracy longer battery life additional functionality and improved safety features MIT510 2 A rugged portable tester designed for years of trouble free operation e Dual operation from AC line or rechargeable batteries so testing can continue even when recharging is overlooked e Resistance measurements to 15 TO replacing ambiguous infinity readings with actual numbers than can be used MJ15 and BM15 for trending or predictive maintenance The BM15 and MJ15 are compact 5 kV e Capacitance measurements from insulation testers that are simple to use and 1 nF to 50 pF providing additional A MIT510 2 provide a quick accurate reading of insulation equipment diagnostic information resistance Both instruments offer four test e Test lockout when an external voltage above 50V is present for redundant safety voltage
12. 0 Absorption Ratio and Dielectric Discharge 2500 Capacitance measurements from 1 nF to 5 kV 50 uF providing additional equipment l diagnostic information ME MIT520 2 500 10 KQ 15 TQ e RS232 or USB ports for downloading test results 1000 e A quick start guide in the lid to make field operation A MIT1LO20 2 2500 simple and user friendly 5 kV IEEE43 2000 IEEE Recommended Practices for Testing Insulation Resistance of ME MIT1020 2 900 10 KQO 35 TO Rotating Machinery now recommends testing machines rated above 12kV at LOkV 1000 2500 5 kV test voltages 10 kV The Polarisation Index test is performed on equipment and cables to assess the general condition of the insulation before applying potentially destructive The new MIT 5kV amp 10kV models easily perform both these tests 155 VWESCHLER 800 903 9870 fax 800 903 9590 weschler com info weschler com INSTRUMENTS AEMC Ground Resistance Testers Digital Ground Resistance Tester Models 4620 amp 4630 Clamp On Ground Resistance Tester Models 3711 amp 3731 Measures soil resistivity 4 Point method Measures ground resistance 2 and 3 Point Fall of Potential method Step voltage tests and touch potential measurements Auto Ranging automatically selects the optimum range Designed to reject high levels of noise and interference Extremely simple to operate connect press read LED on faceplate informs operator of high input noise high auxiliar
13. 00V CAT III Operating Temp 14 to 122 F 10 to 50 C lt 85 RH Dimensions 4 95 x 2 75 x 1 28 136 x 70 x 32mm w o Sensors Sensor Cable Sensor 6 152mm Cable 6 ft 2m In XRM each time the memory fills every other of the oldest data samples is discarded to make room for new samples ORDERING INFORMATION AE 2126 37 Simple Logger II Model ML912 with two mini flex probes USB cable batteries amp Dataview software 800 903 9870 fax 800 903 9590 weschler com info wesch ler com WESCHLER INSTRUMENTS AEMC Simple Logger Il Data Loggers Compact size battery operated Easily installed operational in seconds TRMS measurement for accuracy on distorted waveforms Programmable alarm setpoints amp triggers 5 LED indicators display logger status Choice of data storage modes Stores gt 240k measurements in non volatile memory DataView software displays amp analyzes real time data on a PC L111 One L101 One L102 Two MODEL Channels Input Connector Measurement Range Resolution Accuracy 50 60Hz BNC 0 1V AC probe dependent 0 1mV 10 50mV 0 5 of Rdg 1mV 0 1mA 10 50mA 50 1000mV 0 5 of Rdg 0 5mV 50 1000mA 64 samples cycle Programmable from 125mS to 1 day 50V CAT Ill Rating Channels Current Channel BNC 0 to 1VAC use current probes with a voltage output 0 1mA 10 50mV 0 5 of Rdg 1mV 50 1000mV 0 5 of Rdg 0 5mV 5Vrms 7 07V pk pk max 64 samples cycle
14. 1 Connector PAXCDC20 RS232 Serial Communications Card with Terminal Block PAXCDC2C Extended RS232 Card with 9 Pin D Connector PAXCDC30 DeviceNet Communications Card order PAX2A ASSY for factory installation of options amp meter setup Crimson 2 software is a free download from the Red Lion website PAX2A gt SPECIFICATIONS Display Positive image LCD Top Line 6 digit 0 71 18 mm tri color backlight red green orange 199 999 to 999 999 display range Bottom Line 9 digit 0 35 8 9 mm green backlight 199 999 999 to 999 999 999 display range Power 50 to 250 VAC 50 60 Hz 14 VA 21 6 to 250 VDC 8 W Annunciators 4 red setpoint active indicators Units Label 3 programmable characters with tri color backlight Keypad 2 programmable function keys 4 keys total A D Converter 24 bit resolution conversion rate programmable from 5 to 160 readings sec Input Multi function user selectable Current 250 uADC 2 5 mADC 25 mADC 250 mADC 2 ADC Voltage 250 mVDC 2 0 VDC 10 VDC 25 VDC 100 ADC 200 VDC Thermocouple T E J K R S B N and C RTD 100Q Pt a 0 00385 amp 0 00392 120Q Nickel a 0 00672 10Q Copper a 0 00427 Resistance 10002 100002 10kQ Jumper selectable Transmitter Power 18 VDC 50mA Reference Voltage 2 VDC 2 Reference Current 1 mADC 2 Totalizer Time Base Second minute hour or day Batch Can accumulate gate input
15. 2F 331 to 1562 F Thermocouples JC 210 to 760 C EF 400 to 1830 F JF 347 to 1400 F NC 245 to 1300 C KC 244 to 1372 C NF 410 to 2370 F KF 408 to 2501 F SC 46 to 1 68 C TC 257 to 400 C SF 51 to 3214 F TF 430 to 752 F RC 45 to 1768 C EC 240 to 1000 C RF 49 to 3213 F Note The same temperature signal conditioner board can be user configured for all T C and RTD types TRMS Volts RMV1 200 00 mV RMV2 2 0000 V RMV3 20 000 V RMV4 200 00 V RMV5 600 0 V Not Agency Approved RMV6 300 0 V RMA1 2 0000 mA RMA2 20 000 mA RMA3 200 00mA RMA4 5 000A Note The same AC RMS signal conditioner can be user configured for AC Volts or Amps Load Cells 6 wire ratio WM1 99 999 to 99 999 Note Excitation is 10V DC for up to four 3500 load cells in parallel TRMS Amperes 22 WESCHLER 800 903 9870 fax 800 903 9590 weschler com info weschler com INSTRUMENTS Red Lion Deluxe Panel Meters e Process Voltage Current Temperature amp Strain Gage Inputs e 5 Digit 0 56 Sunlight Readable Red Display Green Optional e Variable Display Intensity cus LISTED e 16 Point Scaling for Non li Processes 6 Point Scaling for Non linear Pro PAX gt e Four Setpoint Alarm Outputs Optional 1 8 DIN NEMA 4X IP65 Front Bezel DSP PAR FA ow RSI CE e Digital Communication Options Free Setup Software e Retransmitted Analog Output Optional The PAX Analog Panel Meters offer many features an
16. 40VAC also charges Resolution 1 100 div both axis batter Zoom x2 X10 both axis DC Power 10 16VDC 10W max Display 4 3 TFT color LCD 480x272 Temperature 0 40 C operating lt 80 RH Volts Display A digit autoranging Dimensions 7x4x1 6 176x101x41mm RECORDERS DATA LOGGERS e Simple USB PC interface Wave application software displays amp prints waveforms converts data to CSV format Includes report templates with figure annotation amp comments XP Vista compatible PRO Kit includes 8870 20 2 pair alligator clip voltage leads AC adapter rechargeable battery hard carrying case 256M flash card USB cable Wave software Extech TRMS Data Logger e Simultaneously measure two AC Voltage inputs or two AC Current inputs or one AC Voltage amp one AC Current input Programmable sample rate from 1 second to 24 hours e Store up to 256 000 readings e LCD indicates time date present readings and Min Max e USB interface e Readings can be analyzed using the included software or exported to a spreadsheet SPECIFICATIONS ORDERING ACCESSORIES INFORMATION HK 9018 50 Clamp on Current Probe 10 500A HK 8870 20PRO HK 9132 10 Clamp on Current Probe 20 1000A HK 9320 01 4 Channel Logic Probe 50V DC max HK 9321 01 4 Channel Logic Probe 250V AC DC max HK 9322 1000 1 Differential Probe 1kVAC 2kVDC max Portable Memory Recorder Kit AEMC AC Current Data Logger e Two integral MiniFlex flexible
17. 555 HK 9453 4 terminal lead set HK 9466 Remote Control Switch for 3554
18. 800 903 9870 fax 800 903 9590 weschler com info weschler com WESCHLER IX SHENOY SIN IBS Laurel High Performance DPMs FEATURES OPTIONS all outputs isolated e 99999 Display Span e Dual Setpoint Relay Outputs e User Selectable Ranges e Linearized Isolated Analog Transmitter Outputs e USB RS 232 amp RS 485 Data I 0 Custom Curve Linearization Datalogging PC Software e 60 Readings Per Second e Adaptive Digital Filter e 1 8 DIN NEMA 4X Front z e 5 10 24V DC Excitation Out Laureate DPMs offer exceptional accuracy at high reading rates Advanced programming features provide flexibility in measuring DCV ACV DCA ACA temperature weight strain process amp pot follower SPECIFICATIONS Display Five 14 2 mm 56 high LED digits A to D Conversion A to D rate 60 s at 60 Hz 50 s at 50 Hz Display update 3 5 s at 60 Hz 3 s at 50 Hz Accuracy at 25 C DC Process lt 0 01 FS 1 ct Strain Load lt 0 01 FS 1 ct True RMS lt 0 1 FS 10 Hz 10 kHz CF 3 0 at full scale AC or DC coupled Thermocouple lt 0 2 C RTD lt 0 1 C Noise Rejection CMR DC to 60 Hz 130 dB NMR to 50 60Hz line 90 dB with min filtering Transducer Excitation Output std Output 100 mA 5V 120 mA 10V 50 mA 24V Dual Relay Output opt Contact relays 8A 250 Vac or 24 Vdc Solid state relays 0 13A 140 Vac or 180 Vdc Linerarized Analog Output opt Level 0 20 mA 4 20 mA 0 10 Vdc 10 V Resolution 16
19. Inputs 0 10 V 0 1 mA 4 20 mA Span error lt 0 015 of full scale 1 count Span tempco lt 0 003 of reading C Zero tempco lt 0 001 of full scale C QD Signal Conditioner Inputs Quadrature encoders to 250 kHz Polarity Differential or single ended Error correction Zero index z channel Transducer Excitation Output std Output 100 MA 5V 120 mA 10V 50mA 24V Isolation 50 Vdc to meter ground Data Communications opt Type USB RS 232 RS 485 2 or 4 wire RS 485 Modbus RTU Modbus ASCII or Laurel ASCII Operating Temperature 0 C to 55 C 39 RESET ALARMS 4 ORDERING INFORMATION Example L50010FR UL Laureate with plug in screw terminal connectors J Main Board 5 Meter with green LEDs 6 Meter with red LEDs T Extended green LEDs 8 Extended red LEDs U Power 0 85 264 Vac 90 300 Vdc 1 10 48 Vdc 12 30 Vac U Setpoint Output 0 None 1 Dual 8 A relays 250 Vac 24 Vdc 2 Dual 130mA solid state relays 140 Vac 180 Vdc U Analog Output 0 None 1 0 20 mA 4 20 mA 0 10 V 10 V U Digital Interface 0 None 5 USB 1 RS 232 Isolated 6 USB to RS 485 Converter 2 RS 485 Isolated 4 RS 485 Modbus Isolated LJ Input Type FR Frequency With main boards 5 amp 6 Scalable to 999 999 for frequency period up down total interval rate or square root of rate With main boards T amp 8 Above plus rate and total simultaneously custom curve linearization atio draw arithmetic functions A B A B A B 1 A B
20. PAX model number for factory installation of options amp meter Connections Cage clamp terminal block setup Crimson software is a free download from the Red Lion website Dimensions 1 95 H x 3 80 W x 4 1 D 50x9 7x105mm 22C W ESCHLER INSTRUMENTS 800 903 9870 fax 800 903 9590 weschler com info weschler com Red Lion Dual Display Panel Meter e Universal Process Inputs DC Current DC Voltage Process Signals Resistance Thermocouples or RTDs e Wide Range Power Supply 50 250 VAC amp 21 6 250 VDC e 6 9 Digit Dual Line Multi Color Display with 0 7 and 0 35 digits e Variable Contrast and Intensity Display e Meter Update Rate up to 160 Second e Up to Four Setpoint Relays e Retransmitted Analog Output e Built in USB port amp Modbus Protocol e R232 amp RS485 Optional The PAX2A is packed full of features that set it apart from other panel meters The input total min max or setpoint value can be displayed on the 0 7 high 6 digit main LCD display The main display also offers three programmable easy to read colors red orange and green The color change can be tied to the setpoints providing the operator with a visual display of changing conditions in the application A second display line is a 0 35 high green LCD that can be programmed for any of the above parameters as well This 9 digit display accommodates totalizing applications that easily exceed the normal 6 digit displays In addition to the dual dis
21. ad and black connector black amp red 10 SPECIFICATIONS Oa ft voltage leads and alligator clips optical Electrical oe USB cable NiMH battery US 120V power Voltage TRMS 660V Phase to Phase 600V Phase to Neutral cord DataView software carrying bag Current TRMS MN Clamp 5mA to 120A or 2 to 240A soft carrying pouch and user manual MR Clamp 10 to 1000AAC 10 to 1400ADC A 8230 PowerPad Jr SR Clamp 3 to 12004 AmpFlex 10 to 6500A Crest factor at 6500 1 DataView Software included with Model 8230 CEE 10 to 70H e Display and analyze real time or recorded data on the PC e Configure all PowerPad Jr functions amp parameters Customize views templates and reports Create and store a complete library of configurations Zoom in and out and pan through sections of the graph Display waveforms trend graphs harmonic spectrums Other Measurements kW KVAR PF DPF kWh kVARh kVAh K Factor Flicker Harmonic Phase Shift Phase Rotation Harmonics THD R THD F V A VA 1st to 50th Direction Sequence Sampling Frequency 256 samples cycle EA E RA E A E E oe cd aoa Data Storage 1 5MB partitioned for waveforms alarms amp trend i 6 Power Source NiMH AA rechargeable battery pack AC Supply 120 230VAC 50 60Hz ORDERING INFORMATION Battery Life gt Eight hrs with display on AE 2130 82 PowerPad Jr Model 8230 w MN93 BK 240A gt 40 hrs with display off recording mode AE 2130 83 PowerPad Jr Model 8230 w SR193 BK
22. and low resistance modes comparator hold e Insulation resistance modes auto discharge e All measurement modes battery indicators e Live wire warning e Low resistance zero adjust lt 3454 11 SPECIFICATIONS Insulation Resistance Test Voltage 250 500 1000V DC Ranges 4 000 40 00 400 0 500 0MQ 1000MQ 1000V only Accuracy 1st effective range 3 rdg 4d Low Resistance Ranges 40 00 400 0 4 000k 40 00k 400 0k 4 000MQ Accuracy 3 rdg 6d 5 rdg 6d at 400kQ or higher AC Volts Measure Range Oto 750V 50 60Hz Accuracy 3 rdg 6d up to 600V Live Wire Warning gt OV 10V across terminals Power supply 4 AA batteries Dimensions 1 0 Wx5 3 HX2 2 D ORDERING INFORMATION HK 3455 01 5kV MQ HiTester with 3m leads USB cable PC software HK 3454 11 1kV MQ HiTester with 1 2m leads HK 9288 Breaker pin for 3454 11 HK 9289 Test probes alligator clips for 3454 11 HK 925 Connection cord for 3454 11 HK 9631 01 Temperature sensor for 3455 1m HK 9750 10m Test Leads for 3455 HK 9459 Rechargeable Battery pack for 3455 HK 9753 AC adapter for 3455 5kV MegOhmMeter e Resistance to 1TO e Ramp function e DAR amp PI calculations e Auto discharge e 99 memory storage 1550B Live circuit voltage warning SPECIFICATIONS Insulation Resistance 250V 200 kQ 50 GQ 500V 200 kQ 100 GQ 1000V 200 kQ 200 GQ 2500V 200 kQ 500 GQ 5000V 200 kQ 1TQ Step Size 50V
23. arameters in each display mode Recording V A Hz Power Harmonics Q Cap Temperature Scope Battery life Rechargeable Ni Cd pack charger included 6 hrs typical continuous OPTIONAL ACCESSORIES i200s 240A AC current probe 80i 1000s 1000A AC current probe i2000flex 2000A flexible AC current probe SOTK Thermocouple module 80T IR Non contact infrared temperature probe PAC91 Parallel printer adapter 800 903 9870 fax 800 903 9590 weschler com info weschler com Hioki Megohm Testers e Tests insulation on transformers cables amp motors e Calculates PI Polarization Index and DAR Dielectic Absorption Ratio e Temperature measurement amp compensation e Step voltage testing e Leakage current display SPECIFICATIONS Insulation Resistance Test voltage 250V 500V 1kV 2 5kV 5kV DC Manual adjust 25V step lt 1kV 100V step gt 1kV Resistance 0 00MQ 5TQ in 7 ranges 5 rdg 5d for test current gt 100nA Leakage current 1 00nA 1 2mA in 6 ranges 2 5 rdg 5d above100nA Voltage Measure 50 750V AC 50 60Hz 50 1000V DC 5 rdg 5d Temperature 10 0 to 70 0 C 1 5 C PI DAR test Times are user programmable Step voltage test 5OOV 2 5kV in 500V steps 1kV 5kV in 1kV steps Compensation Displays the resistance based on reference temperature Compatible to 10 insulation materials Timer 30s to 30min Data memory Manual recording 100 data Interval recording 360 times x
24. bps half duplex ASCII or Modbus RTU protocols Accessories Operating Temperature 0 to 50 C 5 to 85 RH non condensing YE 90060 Type K thermocouple Storage Temperature 20 to 60 C lt 90 RH non condensing 48 length with mini plug Size 6 1 x 6 1 x 2 2 155x155x55mm without projecting parts or rubber boot YE 93037 Carrying case Weight 1 8 Ibs 800g without battery or rubber boot YE 94009 Lithium ion battery 2 4Ah 7V Safety EN61010 1 Measurement Category Pollution degree 2 Rated transient 350Vp p YE 91011 RS232 cable to PC 9 pin ORDERING INFORMATION YE 93039 Stand for tilted desktop wall YE XL121 D SP1 8 channel Portable Data Station Kit Plug in screw terminal block accepts wires or DIN rail mounting YE XL122 D SP1 16 channel Portable Data Station Kit Plug in screw terminal block accepts wires YE XL900 Datum LOGGER PC data SYE XL124 D SP1 16 channel Portable Data Station Kit M3 screw terminal block accepts wires or lugs analysis software WinXP no RTD inputs 120 800 903 9870 fax 800 903 9590 weschler com info weschler com WESCHLER INSEE SIRS West Paperless Recorder Hioki Data Loggers e 6 4 color TFT display NEW e Web based visualization amp configuration e 4 8 or 12 universal 16 bit inputs e Up to 12 relay outputs e Channel visualization in up to 8 groups e USB memory stick data storage or e Ethernet interface for configuration e RS 485 Modbus master slave e Mathematical fun
25. ctions in realtime Miniature size 16 000 or 32 000 reading storage e Data is retained even when the batteries are dead e Power saving function V r VU e IP 65 NEMA 4X front A vu3 Model Range Memory Feature SPECIFICATIONS Temperature HK 3632 20 20 to 70 0 C 16k Waterproof with Inputs built in sensor T C J K T R S E N B L HK 3633 20 40 to 180 0 C 16k External internal RTD Pt100 Ni120 sensor waterproof DC mV 0 50 10 50 Temperature amp Humidity o 0 V 0 5 1 5 0 10 2 10 HK 3641 20 40 to 85 0 C 0 100 0 RH 16k Alternately record on l two channels mA 0 20 4 20 Caren Basic Accuracy HK 3634 20 0 20 00mA DC 16k T C 0 1 of span 0 3 C HK 3636 20 0 50 00 500 0A AC RMS 32k 2ch with optional RTD 0 1 of span 0 3 C o apenso DC 0 1 of span 1d HK 3638 20 AC Leakage Current 32k 2ch with optional _ clamp on sensor Scan Rate 200ms minimum Voltage Outputs HK 3635 24 500 0mVDC 16k Relays 3A 250VAC 0 1A 250VDC resistive HK 3635 25 5 000VDC 16k Analog Six 0 20 or 4 20ma 12 bit HK 2635 26 50 00VDC 16k Cemi a aiite HK 3645 20 50 00mV 500 0niv 32K Muli Tange logger wih Ethernet Modbus TCP 5 000V 50 00DC preheat signal function RS 485 Modbus RTU HK 3639 20 9 999county interval 32k Pulse Totalizer 1ch Display 640x480 color TFT HK 3640 20 2000 20000 200000 lux 32k Illumination 1ch Memory 150Mb internal flash 16k readings unit have record interval of 2 5 10 15 20 30
26. d Resistance Tester Model 6472 4 point Kit 500 100 ft leads AE 2117 61 Ground Resistance Tester Model 3731 Clamp On with memory and alarm AE 2135 01 Ground Resistance Tester Model 6470B AE 2135 72 AC Current Probe Model SR182 for use with Model 6472 Kit includes Tester test leads 30 ft ground lead green auxiliary ground electrodes spaded lugs 100 ft tape measure ground tester work book CD carrying bag for meter carrying bag for kit 6470B gt TEST EQUIPMENT AE 2135 04 Ground Resistance Tester Model 6470B 4 point Kit 500 100 ft leads AE 2135 52 Ground Resistance Tester Model 6472 3 point Kit 150 ft leads AE 2135 71 AC Current Probe Model MN82 for use with Model 6472 2 probes required for two clamp testing method 159 TEST EQUIPMENT WESCHLER INSTRUMENTS Megger Clamp on Testers NEW _ Ground Resistance Testers e Easy fast clamp on operation No rods or cables needed e Measure ground resistance from 0 05Q to 1500Q e Measure ground leakage or phase current from 0 5mA to 35A e Auto ranging with high amp low alarms e Automatic self calibration e Data storage amp USB interface DET24C APPLICATIONS Measure resistance and continuity of grounding loops around pads poles and buildings Check multi grounded systems without disconnecting the ground rod stake under test Measure leakage current flowing to ground or circulating in ground systems Use on cell towe
27. d perform SPECIFICATIONS ance capabilities to suit a wide range of industrial applications Five Range Resolution InputR_ Max Input Basic Accy different models handle various analog inputs with 3 to 5 digit res PAXD gt OE 23 C dilution 200 uADC 10nA 1 111 KQ 15 mA 0 03 3d i 2 mADC 0 1 uA 111 50 mA 0 03 3d The meters provide a MAX and MIN reading memory with program 20 mADC 1 uA 119 150 mA 0 03 3d mable capture time The capture time is used to prevent detection of 200 mADC 10 uA 10 500 mA 0 05 3d false max or min readings which may occur during start up or unusu 2 ADC 0 1 mA 0 10 3A 0 5 3d al process events The signal totalizer integrator can be used to 200 mVDC 10 uV 1 066 MQ 100 V 0 03 3d compute a time input product This is useful to provide a readout of 2 VDC 0 1 mV 1 066 MQ 300 V 0 03 3d totalized flow calculate service intervals of motors or pumps The 20 VDC 1 mV 1 066 MQ 300 V 0 03 3d totalizer can also accumulate batch weighing operations 300 VDC 10 mV 1 066 MQ 300 V 0 05 3d 100 Q 0 01 Q 0 175 V 30V 0 05 3d Four setpoint output can be configured to suit a variety of control 1000 Q 010 1 75 V 30V 0 05 3d and alarm requirements A linear DC output 20 mA or 10 V can be 10 kQ 10 17 5 V 30V 0 05 3d scaled independent of the input range and can track either the PAXP input totalizer max or min readings 20 mADC 1 uA 20 Q 150 mA 0 03 2d Communication and bus capabilities are also available as
28. e 4 hour Li ion rechargeable In camera AC adapter 3 hours to 90 capacity AC adaptor 90 260VAC 50 60Hz 32 122 F 0 50 C 20 80 RH non condensing 8 8x3 1x3 3 223x79x83mm lt 120z 340g including battery Complete with 512MB miniSD Card Li lon rechargeable battery 100 260V AC adaptor charger QuickReport software USB Mini B cable built in manual lens shutter and hand strap Deluxe Infrared Thermal Camera e 4 to 662 F 20 to 350 C temperature range e 3 5 89mm color LCD 112ET gt c lt 109ET 000007 ELAPSED TIME 2153ET gt saa Pog of Of 04 03 01 E lt 55ET 57ET gt Sempron 0 10 0 0 03 10 HOURS lt 1357ET e 6 Digit Readout e No Reset Capability Virtually Tamper proof e Six Case Styles e VA and 31 2 sizes e AC and DC Models e Phenolic cases with glass windows Accumulate running time and monitor life of AC or DC powered equipment Synchronous motor provides accurate hour indication to 99 999 9 hours Connect in parallel with the equipment being monitored ORDERING INFORMATION Model Size Catalog Voltage e 120 x 120 pixel image resolution e Picture in Picture visual thermal 1O9ET 1 S1 03618 10 80 VDC e Built in laser pointer 112ET 11 4 S1 03622 120 VAC e SD Memory Card 1000 images on e Rechargeable 5 hour battery poe 2 eae cite 57ET 31 2 SI1 03590 120 VAC Includes memory card batter
29. elay Outputs e Scaling in Engineering Units Isolated Analog Outputs e Crystal Time Base Error e USB RS 232 amp RS 485 Data I O lt 0 001 e Custom Curve Linearization e Sensor Excitation Output Datalogging PC Software e 1 8 DIN NEMA 4X Front Panel Exceptional flexibility is provided by advanced programmable fea tures and by modular architecture with a choice of main boards basic or extended signal conditioners FR VF or QD power sup plies analog output relay outputs and serial data O The FR module provides two independently scalable frequency pulse input channels These channels can be combined arithmetically to display the sum or difference of two flows the ratio of two rates etc As a counter each channel may be independently set and scaled to count up to or down from a preset value The dis played channel A or B is selected via front panel pushbutton The totals are stored in non volatile memory amp retained in the absence of power Display Six 14 2 mm 56 high LED digits Conversion Technique Frequency measurement technique 1 period Rate Gate time 30 ms 0 2 input periods Gate time Selectable 0 to 199 99 sec Scale Factor 10 to 10 Isolation 250V RMS working 2 3kV RMS test FR Signal Conditioner 2 channels Inputs AC pulses from NPN or PNP transistors contact closures magnetic pickups Level 12 mV min 250 Vac max Frequency CH A O Hz to 1 MHz CH B O Hz to 250 kHz VF Signal Conditioner
30. ernal memory flash card capability e Ethernet USB RS232 amp RS485 e Wide viewing angle 3 5 color LCD e Web server FTP client and email functions e Trigger and alarm functions SPECIFICATIONS Input Type Accuracy Resolution DCV 100 500mV 1 5 10 50V 1 5V FS 0 1 ES 10uV TC K E J T L U N 0 05 FS 1 C 0 1 C TC W R S B 0 05 FS 2 C 1 C 3 wire RTD Pt100 JPt100 0 05 FS 0 5 C 0 1 C Pulse Instantaneous value integration revolution Logic Voltage contact Maximum Input 50V CE Measurement Interval 100 200 500ms 1 2 5 10 20 30s 1 2 5 10 20 30 60min 8 ch max for 100ms _ Data Storage 16MB internal memory External storage Compact flash memory card Type Il SD card SP1 Kit includes mating screw terminal USB memory copy function only block US power cord rechargeable battery Functi Ach Tri functi tri nada aa a protective rubber boot carrying case utility unctions Alarm output ch rigger unction pre rigger riggerdelay Ca culation inter channe software amp manual calculation linear scaling statistical operation Average Automatic Measurement Display Screens Waveform digital bargraph waveform digital alarm summary log Utility software for Windows XP displays data Communication 10Base T 100 BaseTX Ethernet SMTP HTTP FTP TCP IP SNTP protocols amp waveforms copies data converts to CSV USB 1 1 Windows XP saves settings amp files RS 232 2 4 38 4kbps RS 485 2 4 115 2k
31. ires to connect e 50 400 600A TRMS ranges e One button operation e Alarm function e 5 LED indicators display logger status e Optically isolated USB 2 0 output e Includes DataView software for data storage real time display analysis amp report generation e 300V CAT IV GOOV CAT III A CL601 Each Simple Logger II includes USB cable Dataview CD batteries amp manual 124 WESCHLER INS TRUMEN TS 800 903 9870 fax 800 903 9590 weschler com info weschler com Extech Thermal Imagers NEW Simpson Elapsed Time Meters Affordable i5 InfraRed Camera e Pocket sized and fully automatic e 2 accuracy 0 1 C sensitivity e Large 2 8 color LCD e 80 x 80 pixel image e gt 4 hour continuous operation e IP43 dust splashproof housing e MiniSD card stores up to 5000 images SPECIFICATIONS Temperature Range Image Storage Emissivity Field of View Focus Distance Detector Type Spectral range Display Image Controls Set up Controls Measurement Modes Battery Charging System AC Operation Operating Temp Dimensions Weight 32 482 F 0 250 C 5000 images mini SD card memory Emissivity table 0 1 to 1 0 adjustable 17 x 17 0 6m 2 ft min focus free Focal plane array FPA uncooled microbolometer 7 5 to 13um 2 8 color LCD Palettes Iron Rainbow and Black White Date time C F 21 languages Spot corrected for emissivity and reflected temperatur
32. l parameters and harmon ics as well as capturing voltage events Sets up in seconds with the included flexible current probes and color display SPECIFICATIONS V rms Wye Ranges 57 66 110 120 127 220 230 240 260 277 347 380 400 417 480 V ac Includes soft carrying case 4 flexible current probes V rms Delta Ranges 100 115 190 208 220 380 400 415 450 480 600 660 690 720 830 V ac 15 150 3000A voltage leads amp clips RS 232 PC Resolution 0 1 V interface cable Power Log software AC adapter manual A rms Ranges 15 150 3000 A rms at sine with supplied flex clamps Resolution 0 01 A ORDERING INFORMATION PF Power factor Range 0 1 Resolution 0 001 Fluke 1735 Power Logger Frequency 46 54 Hz and 56 64 Hz Resolution 0 01 Hz Accessories Power Measurements P active S apparent Q reactive D distorting FL MBX 1A 5A_ Clamp for secondary CT applications Energy Measurements kWh KVAh KVARh FL MBX 5A 50A Clamp for general applications Display 14 VGA Graphic Color 320x240 pixel with background lighting FL CS34 a Watertight hard carry case with rollers L Battery Life Typical gt 12 hours with backlight low and gt 6 hours with backlight high Working Temperature 10 C to 50 C 14 F to 122 F Dimensions 240 mm x 180 mm x 110 mm 6 1 in x 4 6 in x 2 8 in a Portable Data Logger e 8 or 16 isolated analog input channels e 1 pulse and 2 digital logic inputs e Supports direct TC RTD and DCV inputs e 100msec to 1 hour sample interval e 16MB int
33. m 10 Measurement e Use cursors to read time and date of sags and swells e Catch voltage transients and waveform distortion e See current at the instant of voltage events e Catch and save up to 4O transients e Correlate the cause of distortion with time and date stamps e 3 Year Warranty The Fluke 43B includes a hard case voltage and current probes FlukeView PC software and cable line voltage adapter battery charger applications manual power quali ty video and users manuals ORDERING INFORMATION Fluke 43B Power Quality Analyzer 151a The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems troubleshoot power problems and diagnose equipment failures All in a rugged handheld package Function Measurement Accuracy Selection Volts 5 000V 600V RMS AC amp DC Amps 50 00A 50 00kA RMS AC amp DC 1 10d Mains Frequency 40 0 70 0Hz 0 5 2d Watts VAR VA 250W 2 5MW 4 4d PF DPF 0 25 1 00 0 04 Sags amp Swells 4 min 16 days selectable Transient Capture Select 20 50 100 200 above Up to 40 transients or below line voltage Thrush Current 1s to 5 min selectable Ohms 0 6 5d Capacitance 2 10d Scope Dc ac actdc peak Sampling rate 25MS sec peak peak Hz duty cycle Bandwidth phase pulse width crest Voltage BW Channel 1 2OMHz factor Current BW Channel 2 15kHz Screen Saves 10 screens 4 min 16 days selectable p
34. n be added with upgrade kit SPECIFICATIONS 10 neutral 10 split phase 10 IT no neutral 30 WYE 30 A System Configuration 3 IT 3 hi leg 30 open leg 30 2 element 30 2 element Voltage Inputs Four 3 phases neutral dc coupled Maximum 1000V rms 6kV maximum peak measured Bandwidth gt 10kHz up to 100kHz for transient display Accuracy ac dc 435 0 1 of nominal voltage 434 0 5 of nominal Current Inputs Four 3 phases neutral dc coupled Range Determined by clamp on probes used Nominal Frequency 40 70Hz BW gt 10kHz Accuracy ac dc 435 0 5 20d 434 1 5d with supplied probes Watts VA VAR 1 0 20 00MW resolution 0 1 to 1 kW Accuracy 435 1 10d 434 1 5 10d e Four voltage and four current Sampling 16 bit resolution 200k samples second max ORDERING INFORMATION channels capture waveform data Logger Function Captures up to 10000 events 100 parameters phase Fluke 435 3 Power Quality Analyzer on all phases simultaneously Display 4 5 x 3 4 Color LCD 320x240 pixel Fluke 434 3 Power Quality Analyzer e Meter display of phase readings Power 115 230V ac or battery built in battery charger Fluke Power Quality Analyzer e Voltage current and power harmonics up to 51st e Total harmonic distortion THD e Phase angle of individual harmonics e Watts power factor displace ment power factor VA and VAR e Voltage and current waveforms e Calculates 30 Power on Balanced Load fro
35. option 10 VDC 1 mV 900 kQ 300 V 0 03 2d cards Readout values and setpoint alarm values can be controlled _PAXH TRMS AC or AC DC 50 400 Hz through the bus Once the meters have been initially configured the 200 mVAC 10 pV BG KEY 3OV_ 0 1 40d__ parameter list may be locked against further modification or only the our e a ie sai ae ay Stas H i o setpoint values can be made front panel accessible Saone O ec 00 Oia ORDERING INFORMATION 200 WAAC 10 nA 1 11 KQ 15 mA 0 1 40d To Order Insert Number Code for Each Letter to Select Catalog Number oN E ee 7 Order Example PAXDO100 20 mAAC 1 pA 11 1 2 150 mA 0 1 20d te 200 mAAC 10 uA 1 1 Q 500 mA 0 1 20d A C 5 AAC 1 mA 0 02 Q 7A 0 5 5d is PAXS 2 or 4 wire A Input 24 mVDC 1 pV 100 MQ 30 V 0 02 3d D DC Voltage Current 240 mVDC 10 uV 100 MQ 30 V 0 02 3d P Process l PAXT Range Accuracy 23 C Accuracy 0 50 C H AC TRMS Voltage Current requires 85 250V supply 100 Q Pt 385 392 200 to 850 C 0 4 C 1 6 C S Strain Gage Bridge 120 Q Nickel 672 80 to 260 C 0 2 C 0 5 C T Thermocouple RID 10 Q Copper 427 100 to 260 C 0 4 C 0 9 C B LED Displa TC Type T 200 to 400 C 1 2 C 2 1 C 00 Red Sunlight Readable TC Type E 200 to 871 C 1 0 C 24 C ON Geen Type 200 to 760 C 1 1 C 2 3 C Powe Tp K 200 to 1372 C 1 3 C 3 4 C 00 85 250 VAC TC Type R S 50 to 1768 C 1 9 C 4 0 C 10 11 36 VDC 24VAG CT Type B 100 to 300 C 3 9 C 5 7 C Plug In Options 300 to 1820 C 2 8 C
36. or clips optical Voltage TRMS 660V Phase to Phase 600V Phase to Neutral USB cable six 1 5V batteries two safety Current TRMS MN Clamp 5mA to 120A or 2 to 240A test probes DataView software carrying MR Clamp 10 to 1000AAC 10 to 1400ADC bag soft carrying pouch and user manual SR Clamp 3 to 1200A AmpFlex 10 to 6500A Crest factor at 6500 1 Three line backlit digital display with custom icons Frequency 40 to 70Hz ORDERING INFORMATION Other Measurements kW KVAR PF DPF VA Harmonics Phase Rotation Temperature RPM Resistance Continuity Diode Test AE 2130 91 Power Quality Meter Model 8220 w MN93 BK 240A Sampling Frequency 256 samples cycle AE 2130 92 Power Quality Meter Model 8220 w SR193 BK 1200A Data Storage Stores nine sets of readings AE 2130 93 Power Quality Meter Model 8220 w 24 AmpFlex 193 24 BK 6500A Power Source Six 1 5V AA Alkaline batteries gt 8hr life with display on AE 2130 94 Power Quality Meter Model 8220 w 36 AmpFlex 193 36 BK 6500A AC Supply 120 230VAC 50 60Hz optional AE 2130 95 Power Quality Meter Model 8220 w MR193 BK 1000AAC 1400ADC Communication Port Optically isolated USB AE 2130 96 Power Quality Meter Model 8220 w MN193 BK 6A 120AAC Dimensions 8 3 x 4 3 x 2 4 211 x 108 x 60mm 151 NiMH battery pack 435 Includes Hard carrying case with rollers four flexible current probes i430 flex five test leads and clips battery charg er FlukeView software Power
37. plays the meter also includes a 3 character programmable unit indicator Beyond the display the PAX2A provides the maximum in configuration flexibility allowing users to stock just one meter for numerous applica tions Featuring universal input the same meter accepts DC current DC voltage process signal plus thermocouple and RTD temperature sensor inputs The PAX2A also has a wide range AC DC power input With its dual display and versatile functionality the PAX2A delivers an ideal solution for applications that require two parameters to be visu alized at the same time e g present temperature and setpoint value or flow rate and total gallons The Crimson 2 setup software allows quick and easy configuration of the meter from any PC using the supplied USB cable Signal Input User Functions Display Locks Secondary Parameters Totalizer Setpoint Alarms Serial Comms Analog Output ORDERING INFORMATION Dual Display Process Meter USB cable panel gasket and mounting clip included Plug In Options PAXCDS10 Dual Form C Setpoint Relays 5 A 240 VAC or 28 VDC res PAXCDS20 4 Form A Setpoint Relays 3 A 250 VAC or 30 VDC res PAXCDS30 4 Setpoint Sinking Open Collector Outputs 0 1A 50V PAXCDS40 4 Setpoint Sourcing Open Collector Outputs 0 1 A 30V PAXCDL10 Analog Output Card 0 20 4 20 mA 0 10 VDC PAX2A PAXCDC10 RS485 Serial Communications Card with Terminal Block PAXCDC1C Extended RS485 Card with Dual RJ1
38. pply outputs D Special Functions Settings that can be made through the main unit recording interval recording start stop 0 None 4 Batch Math Settings that can be made through the Communication Base current time recording 1 Batch report 5 Baca Aann interval recording start time recording method comment 2 Math functions 6 Math Ext channels HK 3911 20 RS 232 Communications Base 3 External channels 7 Batch Math Ext ch HK 3920 20 USB1 1 Communications Base 122 WESCHLER INSTRUMENTS 800 903 9870 fax 800 903 9590 weschler com info weschler com Hioki Portable Recorder AK MOTO wee eee e Ideal for transient capture amp long period recording e Compact easy to carry e 4 3 color LCD display e 2 analog amp 4 logic inputs e Sample rates up to 1M sec e Analog inputs isolated to 300V SPECIFICATIONS Input 2 isolated BNC 300V max Memory 12 bits x 2Mwords ch Range 10mV 50V div Expansion 1GB flash card Type1 Accuracy 0 5 of full scale Calculations 4 simultaneous saved to Bandwidth DC 50kHz 3dB flash card Trigger Level logic manual ext Calculation Types Avg peak min max RMS Trigger Mode Single continuous freq period Time Axis 100ms 5min div Screen Capture Saved to flash card Record Length 20 20000 div 10 settings PC Interface USB 2 0 mini B Record Time 2s to 69 days Battery Rechargeable 2 hr life with Sample Rate ims to 3s continuous use Pre trigger 0 100 of record length AC Adapter 100 2
39. rs e Test without disconnecting the batteries e Three level indication Pass Warning Fail e Audible beeper 3555 e PC Interface amp software 3554 Get an instantaneous check of battery condition based on internal resistance and voltage Model 3554 for medium and high capacity lead acid batteries Model 3555 for compact storage batteries used in portable telephones and similar applications SPECIFICATIONS 3554 3555 Measurement Ranges Ohms 3uN 3Q 300u 9 309 Ranges 4 3 Best resolution 1uQ 100uQ Accuracy 0 8 rdg 6d 0 8 rdg 6d Test Current 150mA 1 5mA 5mA 50uA DC Volts 6V 60V 3V 30V Best resolution 1mV 1mV Accuracy 0 08 rdg 6d 0 1 rdg 6d Temperature 10 to 60 C Resolution 0 1 C Test Frequency 1kHz 1kHz Max Input 60V DC 50V DC Comparator Hi amp low ohm limit low volt limit both models Limit Sets 200 stored 10 stored Data Memory 4800 data limit sets Alert LCD icon LED amp Beeper Batteries 9 x AA 6 x AA Life up to 10 hrs up to 18 hrs PC Interface USB Operating Temp 0 40 C lt 80 RH non condensing Dimensions SUPPLIED ACCESSORIES 7 7 x 5 1 x 2 2 196x130x55mm 3554 Pin type test leads USB cable data management sofware carrying case zero adjust board batteries spare fuse 3555 Pin type test leads batteries ORDERING INFORMATION HK 3554 Battery Tester lead acid batteries HK 3555 Battery Tester portable batteries HK 9382 Carry case for 3
40. rs RF transmitters and telecom sites Inspect and verify lightning protection systems Test consumer installations including pools spas etc Backlit LCD display can be read in bright sunlight Large 39 x 55mm jaw with 39mm 1 5 opening Noise filter for stable readings in noisy environments Hold function for difficult to reach installations 24 hour battery life with auto off to save on battery power Two alarms with adjustable threshold amp audible indication Stores 2000 test results DET24C Calibration check loop insures proper operation CAT IV 600V safety rating Range Resolution Accuracy Range Resolution 0 05 0 999 0 010 1 5 0 0502 0 5 0 99mA 0 01mA 1 00 9 992 0 010 1 5 0 10 1 00 9 99mA 0 01mA 10 0 99 99 0 102 2 0 50 10 0 99 9mA 0 1mA 100 0 199 902 0 102 5 10 100 999mA 1mA 200 40002 10 6 5Q 1 00 9 99A 0 01A 400 600 10 10 10Q 10 0 35 0A 0 1A 600 12002 100 20 TRMS reading CF lt 5 50 400Hz 1200 150002 1002 35 Basic Accuracy 2 50 60Hz Model DET24C includes USB interface IrDA dongle and software for downloading test data Both models include batteries carrying case carrying strap amp calibration loop ORDERING INFORMATION Digital Earth Test Clamp on Meter ME DET24C Digital Earth Test Clamp on Meter with USB ME DET14C 161 800 903 9870 fax 800 903 9590 weschler com info weschler com Hioki Battery Teste
41. s 500 V 1 kV 2 5 kV 5 kV analog e Simple operator controls and a quick start guide in the lid for efficient use of test time scales and measurement sensitivity to MIT520 2 20 GQ All the features of the MIT510 plus expanded capabilities to afford the skilled operator Both units include pass fail display more flexibility in analyzing and reporting the condition of capital equipment overlays for a rapid go no go testing Test voltage can be set in 10 V increments from 50 V to 1 kV and in 25 V increments and trend analysis above 1 kV The BM15 is powered by 8 AA or e Test results can be downloaded via RS232 or USB ports rechargeable alkaline batteries while e Five industry standard tests can be programmed and run automatically the MJ15 includes a hand crank e Insulation resistance IR e Step voltge SV e Dielectric absorption DAR Dielectric discharge DD generator in addition to battery power e Polarization index PI MIT1020 10kV Insulation Tester MIT1020 2 e Test voltage range from 50 V to 10 kV in 10 V increments to 1 kV and 25 V increments above 1 kV ORDERING INFORMATION Catalog No Test Voltage V dc Resistance ME MJ15 500 100 kQ 20GO 1000 ME BM15 2500 As e Increased measurment range to 35 TQ mere for testing the best insulating materials 5 kV e Automatic performance of standardized ME MIT510 2 900 10 kQ 15 TO tests including Step Voltage Dielectric 100
42. seconds 1 2 5 10 15 20 30 60 gt aH a minutes Models with 32k readings also have a 1sec record interval gt Temperature 0 55 C operating 52 m Power 100 240VAC 50 60Hz SPECIFICATIONS M ig Dimensions 5 375 Hx5 44 W x 7 0 D Accuracy Math function option up to 12 additional channels can be defined see oe CORO 0 35 0 C l f E 20 0 5 35 0 with general arithmetic calculations logic operations statistical func 3641 20 0 5 C 0 35 0 C 5 RH at 25 C tions reporting functions amp triggering of automatic sequences 3634 20 0 8 rdg 5d 3636 20 1 rdg 5d main unit only ORDERING INFORMATION 3638 20 1 rdg 5d main unit only To Order Insert Code for Each Letter to Select Catalog Number 3635 24 25 26 __ 0 8 rdg 5d 3637 20 1 rdg 5d Example VU3 400 000 A0 0 vu3 a B c D 3645 20 0 5 rdg 5d 3639 20 1d A Inputs 3640 20 4 rdg 5d 400 4channels 440 8 channels Data Transfer 500 data elements second via infrared link 444 Achaeis Power Supply 2 AAA batteries Dimensions 2 24 Wx2 91 Hx0 77 D B Outputs Environment Indoors 0 C to 50 C lt 80 RH 000 None AOO 12 relays The Communication Base is used to transfer data from a Data Logger to PC It can collect C Transducer Power data on up to 16 channels Data from multiple Data Loggers that are installed in fixed 00 None positions can be collected and then transferred to a PC via RS 232 or USB for analysis and processing AO 12 su
43. sistivity measurement with automatic calculation of Rho amp user selection DataView software external of Wenner or Schlumberger method battery charger power cord 3 Point earth coupling measurement user manual Frequency scan 40 513Hz for testing in electrically noisy environments Selectable test voltage of 16 or 32V up to 250mA of test current Automatic recognition of all electrode connections amp resistance Stores up to 512 complete test results Optically isolated USB communication Rechargeable NiMH batteries from wall charger or vehicle power Rugged dustproof and rainproof field case Includes DataView software for remote operation data storage real time display analysis report generation amp system configuration Model 6742 adds e Manual and automatic frequency scan to 5078Hz e Measures Ground Resistance using the 2 clamp method selective ground testing e Measures Ground Impedance up to 5kHz to test lightning strike protection ORDERING INFORMATION AE 2130 43 Ground Resistance Tester Model 4620 AE 2135 02 Ground Resistance Tester Model 6470B 3 point Kit 150 ft leads 4 Point Digital Battery Powered AE 2130 44 Ground Resistance Tester Model 4630 4 Point Digital Rechargeable Battery AE 2135 51 Ground Resistance Tester Model 6472 AE 2130 45 Ground Resistance Tester Model 4620 Kit AE 2130 46 Ground Resistance Tester Model 4630 Kit AE 2117 60 Ground Resistance Tester Model 3711 Clamp On AE 2135 54 Groun
44. y power supply i40 p gt QuickReport software USB cable hand strap _ 1357ET 32 SI 03595 120 VAC ens cap Mal ase 2153ET 314 SI 17720 120 VAC ORDERING INFORMATION zazi is A AAA EX IRC40 EXTECH i5 Thermal Imaging Infrared Camera 57ET 3 2 S1 03610 240 VAC EX Flir i7 Flir i7 Thermal Imaging Camera 20 to 250 C n 120x120 resolution spot area isotherm measure 1357ET 3 2 SI 03615 240 VAC EX Flir i40 Flir 140 Deluxe Thermal Imaging InfraRed Camera 2153EI 32 SI 17721 240 VAC 127 WESCHLER 800 903 9870 fax 800 903 9590 weschler com info weschler com INSTRUMENTS AEMC Single Phase Power Quality Analyzer e Displays Min Max and Average Volts and e Stores up to eight screen captures Amps Crest Factor Peak value and K Factor e Stores up to 1MB of trend recorded data e Calculates and displays Watts VARs and VA e Configurable from DataView software or Power Factor and Displacement Power Factor front panel for single phase and balanced three phase Captures up to 4096 alarm events using e Displays total harmonic distortion THD F and up to 10 different thresholds TARAB tor voltage and curren e Displays and records up to 17 different e Displays individual harmonic values and for power quality parameters Volts and Amps through the 50th harmonic s Includes Dataview sontware for data e Captures displays and stores inrush current storage real time waveform display analysis waveforms and statistics and report generation le
45. y rod resistance and fault connections Large easy to read backlit display Battery powered Model 4620 AC powered with rechargeable NiMH batteries l Model 4630 Memory function to store 99 field Rugged dustproof and rainproof field case measurements for later retrieval and Can also be used for continuity tests analysis Model 3731 on bonding A 3731 e Meets EN 61010 1 Cat III and CE Mark Color coded terminals US Patent No 362 639 e Rugged Lexan head and body construction resists breakage Ol e Alarm settings and stored memory A 4630 E Eon gt S information saved during shutdown f 2A Also available as full kits Or a Simple and fast clamp on operation no leads no auxiliary rods or spacing requirements Direct reading of ground resistance from 0 10 to 12000 Direct reading of continuity and ground loop resistance Direct reading of ground leakage or phase current from 1mA to 30Arms Jaw design with large 1 25 32mm window accommodates up to 1000MCM cables Auto Off for power management Alarm function with adjustable set point and buzzer for quick field checks Model 3731 Model 3731 Patented design Multi Function Ground Resistance Tester Models 6470B amp 6472 2 and 4 Wire Bond Resistance Continuity measurement Tester includes meter NiMH 3 Point Fall of Potential measurement with manual automatic frequency selection batteries optical USB cable 4 Point soil re
Download Pdf Manuals
Related Search
Related Contents
Wavemaster Stax Laura Ashley PX2414 Use and Care Manual L`Echo des Pilotes n°43 Spécial grève de septembre Untitled - DirectedDealers.com fiche technique Bien que l`EC145 n`ait cessé de gagner en maturité au cours de ces docomo Xperia(TM) A2 SO-04F HP M175a Open Source Licenses Copyright © All rights reserved.