Home
Pierce Magnetic Titanium Dioxide
Contents
1. Related Products Products available from www thermo com pierce 28905 Formic Acid 10 x 1 ml ampules 21358 MagnaBind Magnet for 96 Well Separator 21357 MagnaBind Magnet for one 1 5 ml Microcentrifuge Tube 21359 MagnaBind Magnet for 6 Microcentrifuge Tubes 88800 88801 Pierce Protein A Magnetic Beads 88806 88807 Pierce Protein G Magnetic Beads 88821 88822 Pierce Glutathione Magnetic Beads Products available from www thermo com SC250EXP 115 Express Speed Vac Concentrator SC250 Products available from www thermo com abgene AB1300 Thermo Fast 96 Robotic PCR Plate 0 2 ml well volume Products available from www fishersci com 14 432 22 50 ml Polypropylene Conical Centrifuge Tubes 14 959 49B 15 ml Polypropylene Conical Centrifuge Tubes A955 1 Acetonitrile 1 L 60108 304 HyperSep SPE Columns 60300 428 Hypersil C18 96 well Plates Products available from www vwr com 5400630 KingFisher Flex with 96 Deep Well Head Instrument 97002514 KingFisher Flex 96 Tip Comb for PCR Head Magnets 95040450 Microtiter Deep Well 96 Plate V bottom polypropylene 97002534 KingFisher Flex 96 Tip Comb for Deep Well Magnets Reference 1 Hubbard M J and Cohen P 1993 On target with a new mechanism for the regulation of protein phosphorylation Trends Biochem 18 172 Limited Use License This product is distributed and sold to the End User pursuant to an appointment grant from PerkinElmer LAS Inc to Thermo Fisher Scientific Inc for use of P
2. formic acid a 5 Sample Wash Binding Buffer 130 6 Sample Wash Binding Buffer 130 7 Sample Wash Washing Buffer 130 8 Elution Elution Buffer 30 Perform the Phosphopeptide Enrichment PCR Plate Protocol Select the protocol using the arrow keys in the instrument keypad and press Start See KingFisher User Manual for detailed information Slide open the door of the protective cover on the instrument Load plates 1 8 into the instrument according to the protocol request and confirm each action by pressing Start Place each plate in the same orientation Press Start to initiate the protocol After the samples are processed remove the plates as instructed by the display on the instrument Press Start after removing each plate Press Stop after all plates are removed Transfer samples to a new PCR plate and lyophilize to dryness using a vacuum concentrator For LC MS MS analysis rehydrate each sample in 5 acetonitrile 1 formic acid in water and inject each sample directly from the 96 well plate Alternatively for MALDI analysis resuspend samples in o cyano 4 hydroxycinnamic acid MALDI matrix solution and spot onto a MALDI chip Procedure for Automated Enrichment of Phosphopeptides using Deep well Plates A Additional Materials Required see the Related Products Section for ordering information KingFisher Flex or KingFisher 96 Instrument with 96 Deep Well Head Microtiter Deep Well 96 Plate V bottom polypropylene KingFisher Flex 96
3. Plates ce eeceseecsesecneeeeceeeeecseeecaeceeeseeneeseenee 5 Troubleshooting si sscesaccescssbenstesssseasessiai se ntra Ea e saved EE EAE EEEE EEE EEEE ERE E bhasdus sndssanuzadbonsyansbouseaheetasdansneastabunnas 7 Additional Information sississecsr scoir Maecskspssttacveoebessabap sien yess ES EE EEEE EE E K EE iad A EENE rE EErEE pubes und eb ERE SE oE ea ees 8 Related Products csinaciinenan nn E EEE E Ea a E E E EEE 9 Reference A E E E A E eed ees 9 Introduction Phosphorylation events in complex biological samples are transitory and typically present in low abundance making them difficult to detect The Thermo Scientific Pierce Magnetic Titanium Dioxide Phosphopeptide Enrichment Kit uses titanium dioxide coated magnetic beads to selectively enrich phosphopeptides from complex mixtures such as digested cell lysates The buffers and assay protocols included are optimized for efficient capture in less than 30 minutes with minimal binding of non phosphorylated peptides Purification is achieved either manually using a magnetic stand or by automation using a KingFisher Flex or KingFisher 96 Instrument Cell signaling networks are invariably dependent upon protein phosphorylation a reversible post translational modification for regulation Approximately 30 of proteins comprising the eukaryotic proteome are likely to undergo some form of phosphorylation event Understanding the state of signaling pathways and protein phosphorylation casca
4. The following protocols are designed for general use with the KingFisher Flex or KingFisher 96 Instruments If desired the protocols can be modified as needed using the BindIt Software provided with the instrument 1 C Download the Phosphopeptide Enrichment PCR Plate protocol from the web site www thermo com kingfisher into the BindIt Software on an external computer Transfer the protocol to the KingFisher Instrument from an external computer See BindIt Software User Manual for detailed instructions on importing protocols Prepare the Binding and Washing Buffers Note Prepare buffers just before each experiment Binding Buffer Multiply the number of samples by 510 ul to determine the total buffer volume required Add 5 for excess Combine equal volumes of acetonitrile and Binding Buffer in a polypropylene conical tube 15 ml or 50 ml and mix to obtain a homogeneous solution Close tube tightly to prevent acetonitrile evaporation Washing Buffer Multiply the number of samples by 130 ul to determine the total buffer volume required Add 5 D for excess Combine equal volumes of acetonitrile and Washing Buffer in a 15 ml polypropylene conical tube and mix to obtain a homogeneous solution Close tube tightly to prevent acetonitrile evaporation Prepare the TiO Magnetic Beads and Plate Set up Note The following protocol is for processing less than 1 mg of peptide mixture The protocol uses 10 ul of 20X TiO Magn
5. number of samples plus one by 10 ul to determine the total volume of magnetic beads required Place the determined volume of 20X TiO Magnetic Beads into a 50 ml polypropylene conical tube Note To ensure homogeneity mix the vial of 20X TiO Magnetic Beads thoroughly before use by repeated inversion gentle vortexing or rotating platform Add 190 ul of prepared Binding Buffer for every 10 ul of beads dispensed in Step 2 Screw the cap onto the tube and invert several times to ensure complete suspension of the beads Pipette 200 ul of the bead suspension into each well of the provided 96 well PCR plate Note Periodically mix the bead suspension during dispensing to prevent settling Place the 96 well plate onto a magnetic plate separator for minute The beads will collect in the O ring near the bottom of each well Use a multi channel pipettor to remove the supernatant from the center of the wells Remove the 96 well plate from the magnet Add 200 ul per well of prepared Binding Buffer to the beads Do not pipette the beads up and down Add Binding Buffer quickly to suspend the beads Repeat Steps 5 and 6 twice Manually Perform the Phosphopeptide Enrichment Note For best results desalt the sample peptide mixture on an SPE column or a 96 well device before processing with the TiO Magnetic Beads See the Additional Information Section for protocol Samples eluted from SPE plates or columns in 80 acetonitrile 0 1 formic acid may be dire
6. tip comb for Deep Well magnets Sample peptide mixture 50 ml polypropylene conical centrifuge tubes 15 ml polypropylene conical centrifuge tubes Acetonitrile Formic acid Vacuum concentrator with a 96 well plate rotor Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 5 B Prepare the King Fisher Instrument Note The following protocol is for general use with the KingFisher Flex or KingFisher 96 Instrument Modify the protocol as needed using the BindIt Software provided with the instrument 1 C Download the Phosphopeptide Enrichment Deep Well protocol from the web site www thermo com kingfisher into the BindIt Software on an external computer Transfer the protocol to the KingFisher Instrument from the external computer See BindIt Software User Manual for detailed instructions on importing protocols Prepare the Binding and Washing Buffers Note Prepare buffers just before each experiment Binding Buffer Multiply the number of samples by 3 9 ml to determine the total buffer volume required Add 5 for excess Combine equal volumes of acetonitrile and Binding Buffer in a 50 ml polypropylene conical tube and mix to obtain a homogeneous solution Close the tube tightly to prevent acetonitrile evaporation Washing Buffer Multiply the number of samples by ml to determine the total buffer volume required Add 5 for excess U
7. INSTRUCTIONS Thermo Pierce Magnetic Titanium Dioxide Phosphopeptide Enrichment Kit 88811 88812 2097 0 Number Description 88811 Pierce Magnetic Titanium Dioxide Phosphopeptide Enrichment Kit contains sufficient reagents for enriching phosphopeptides from 96 complex biological samples Kit Contents TiO Magnetic Beads 20X ml Binding Buffer 100 ml Washing Buffer 25 ml Elution Buffer 3 ml Thermo Fast 96 Robotic PCR Plate 0 2 ml well volume 2 plates 88812 Pierce Magnetic Titanium Dioxide Phosphopeptide Enrichment Kit Trial Kit contains sufficient reagents for enriching phosphopeptides from 24 complex biological samples Kit Contents TiO Magnetic Beads 20X 0 25 ml Binding Buffer 100 ml Washing Buffer 25 ml Elution Buffer 3 ml Thermo Fast 96 Robotic PCR Plate 0 2 ml well volume 2 plates Storage Upon receipt store at 4 C Product shipped on an ice pack Contents IntrOGucti ON sespe ices teats a E eae o ices nae racket dee ate ae eo vad ewes EE aeS 1 Important Product Information eserse ei ee eneee EAEE E EEE hanya eee bil vans ed evens ote a 2 Procedure for Manual Enrichment of Phosphopeptides scesecesssssssecseesscseeeecseesesseceeesecneesecsaeceesaecaeesecsesseesaeeeeeaeeeeeeeeaeeatenee 2 Procedure for Automated Enrichment of Phosphopeptides on the KingFisher PCR Plate eeeecesesseseceeeeeeeseeeceseceteeeeneeaes 4 Procedure for Automated Enrichment of Phosphopeptides using Deep well
8. ct s There is no obligation to replace Products as the result of i accident disaster or event of force majeure ii misuse fault or negligence of or by Buyer iii use of the Products in a manner for which they were not designed or iv improper storage and handling of the Products Current versions of product instructions are available at www thermo com pierce For a faxed copy call 800 874 3723 or contact your local distributor 2008 Thermo Fisher Scientific Inc All rights reserved Unless otherwise indicated all trademarks are property of Thermo Fisher Scientific Inc and its subsidiaries Printed in the USA Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 9
9. ctly applied to beads after adding formic acid to a final concentration of 2 Note If sample peptide mixture is not eluted from an SPE device ensure that the peptide mixture is in a final solution of 80 acetonitrile 2 formic acid before applying to the TiO Magnetic Beads Remove the 96 well plate from the magnet Add 100 ul of sample peptide mixture per well to the beads and pipette up and down to mix Place the plate on a magnetic plate separator for 1 minute Use a multi channel pipettor to remove the supernatant from the center of the wells Remove the plate from the magnet and add 200 ul of Binding Buffer per well quickly to resuspend the beads Place the plate on a magnetic plate separator for 1 minute and remove the supernatant Repeat this step three times Remove the 96 well plate from the magnet and add 200 ul of Washing Buffer per well quickly to resuspend the beads Place the plate on a magnetic plate separator for 1 minute and remove the supernatant Completely remove the Washing Buffer before proceeding to the elution step Remove the plate from the magnet and add 30 ul of Elution Buffer per well and pipette up and down a few times to ensure complete coating of the beads with buffer Incubate at room temperature for 10 minutes Place the plate on a magnetic plate separator for 1 minute and remove the supernatant containing eluted phosphopeptides Note Avoid aspirating the beads with the eluates Beads may interfere wit
10. des under a variety Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax of conditions is necessary for studying diseases such as cancer When paired with appropriate sample processing the identification and quantification of phosphopeptides by mass spectrometry MS is a powerful method for studying disease and identifying biomarkers Samples isolated with this phosphopeptide enrichment kit are ready for direct analysis on a wide variety of MS platforms including the Thermo Scientific LTQ Orbitrap LTQ and LTQ FT Mass Spectrometers Important Product Information A wide variety of methods are used to generate phosphopeptide samples Optimization of sample stimulation protein isolation and protein digestion procedures are application specific however for best results use a phosphatase inhibitor such as the Thermo Scientific Halt Phosphatase Inhibitor Cocktail Product No 78420 throughout the isolation process to prevent rapid loss of phosphorylation events Before processing protein samples need to be reduced alkylated and digested into peptide fragments For digestion use highly specific proteases such as Thermo Scientific MS grade Trypsin Product No 90055 or Lys C Product No 90051 For efficient sample handling during manual processing use the 96 well PCR plates provided with the kit and a 96 well magnetic plate separator Do not freeze or allow pr
11. eriment Binding Buffer Multiply the number of samples by 1 590 ul to determine the total volume of buffer required Add 5 for excess Combine equal volumes of acetonitrile and Binding Buffer in a 50 ml polypropylene conical tube and mix to obtain a homogeneous solution Close the tube tightly to prevent acetonitrile evaporation Washing Buffer Multiply the number of samples by 200 ul to determine the total volume of buffer required Add 5 for excess Combine equal volumes of acetonitrile and Washing Buffer in a 15 ml polypropylene conical tube and mix to obtain a homogeneous solution Close the tube tightly to prevent acetonitrile evaporation Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 2 Prepare the TiO Magnetic Beads Use a multi channel pipettor for dispensing buffers and removing supernatant Use 10 ul of 20X TiO Magnetic Beads per sample This volume may be adjusted however for best results use a ratio of 1 ul of stock beads to 10 ug of peptide mixture To minimize bead loss leave up to 10 ul of liquid in the wells when removing buffers however for the last wash step completely remove the Washing Buffer from the bead before adding Elution Buffer Optional Before use rinse all plastic wear such as the 96 well plates three times with acetonitrile to minimize contamination from polymers leaching from the plastics Multiply the total
12. erkinElmer s Phos trap technology for life science research applications but not diagnostics applications Any use of this product other than the licensed use without the express written authorization of PerkinElmer LAS Inc and Thermo Fisher Scientific Inc is strictly prohibited This product Product is warranted to operate or perform substantially in conformance with published Product specifications in effect at the time of sale as set forth in the Product documentation specifications and or accompanying package inserts Documentation and to be free from defects in material and workmanship Unless otherwise expressly authorized in writing Products are supplied for research use only No claim of suitability for use in applications regulated by FDA is made The warranty provided herein is valid only when used by properly trained individuals Unless otherwise stated in the Documentation this warranty is limited to one year from date of shipment when the Product is subjected to normal proper and intended usage This warranty does not extend to anyone other than the original purchaser of the Product Buyer No other warranties express or implied are granted including without limitation implied warranties of merchantability fitness for any particular purpose or non infringement Buyer s exclusive remedy for non conforming Products during the warranty period is limited to replacement of or refund for the non conforming Produ
13. etic Beads per sample This volume can be adjusted however for best results use a ratio of 1 ul of stock beads to 10 ug of peptide mixture Optional Rinse all plastic wear such as the 96 well plates three times with acetonitrile to minimize contamination from leached polymers Multiply the total number of samples plus one by 10 ul to determine the total volume of magnetic beads required Place calculated volume of 20X TiO Magnetic Beads into a 15 ml polypropylene conical tube Note To ensure homogeneity mix the vial of 20X TiO Magnetic Beads thoroughly before use by repeated inversion gentle vortexing or rotating platform Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 4 3 4 Add 120 ul of prepared Binding Buffer for each 10 ul of beads dispensed in Step 2 Screw the cap onto the tube and invert several times to ensure complete suspension of the beads Set up the plates according to Table 1 which will subsequently be placed into a KingFisher Instrument Table 1 Pipetting instructions for the Phosphopeptide Enrichment PCR Plate Protocol using the Thermo Fast 96 Robotic PCR Plates Plate Plate Name Content Volume il well KingFisher Flex 96 Tip Comb Tip Else for PCR Magnet Head j 2 Beads TiO beads in Binding Buffer 130 3 Bead Wash Binding Buffer 130 Sample peptide mixture in 80 sample acetonitrile 2
14. h mass spectrometry analysis Transfer samples to the unused 96 well PCR plate provided and dry in a vacuum concentrator For LC MS analysis using reverse phase chromatography e g C18 suspend sample in 5 acetonitrile 1 formic acid in water Alternatively for MALDI analysis suspend in a matrix of o cyano 4 hydroxycinnamic acid dissolved in 3 formic Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 3 acid 50 acetonitrile prepare on the same day of use Empirically determine the concentration of MALDI matrix to use The optimal concentration depends on MS instrument used and final concentration of peptides in sample Note Covering the matrix after spotting with 1 ul of 25 mM ammonium citrate may enhance detection of phosphopeptides in MALDI MS analysis Procedure for Automated Enrichment of Phosphopeptides on the KingFisher PCR Plate A B Additional Materials Required see the Related Products Section for ordering information KingFisher Flex or KingFisher 96 Instrument with PCR Magnet Head KingFisher Flex 96 Tip Comb for PCR Head Magnets Thermo Scientific Thermo Fast 96 Robotic PCR Plate 0 2 ml well volume Sample peptide mixture 50 ml polypropylene conical centrifuge tubes 15 ml polypropylene conical centrifuge tubes Acetonitrile Formic Acid Vacuum concentrator with a 96 well plate rotor Prepare the KingFisher Instrument Note
15. ide mixture before processing see Additional Information Section Insufficient washing Perform an additional wash Highly buffered starting material prevented the binding buffer from adjusting sample to the required conditions Dilute sample with binding buffer or change sample preparation method PO Box 117 Rockford IL 61105 USA 7 Pierce Biotechnology 3747 N Meridian Road 815 968 0747 815 968 7316 fax www thermo com pierce Additional Information A Visit www thermo com pierce for additional information including the following o Tech Tip 43 Protein Stability and Storage Visit www thermo com kingfisher for information on KingFisher Products In the U S A purchase KingFisher Supplies from VWR Contact your local Thermo Fisher Scientific office to purchase KingFisher Supplies outside the U S A Procedure for Methylation of Carboxyl Groups Note The presence of significant amounts of highly acidic peptides may hinder phosphopeptide enrichment and detection because of carboxyl groups interacting with the TiO surface To minimize this interaction methylate the carboxyl groups before phosphopeptide enrichment Methylation is not recommended for all samples as nonspecific binding is typically low and methylation significantly increases the difficulty of data analysis 1 B Lyophilize a peptide sample and dissolve it in 1 ml of 3 N methanolic HCl Incubate the reaction for 60 minutes at r
16. iter Deep Well 96 Plates Plate Plate Name Content Volume il well KingFisher Flex 96 Tip Comb i Tp Tat for Deep Well Magnets 2 Beads TiO beads in Binding Buffer 1 000 3 Bead Wash Binding Buffer 1 000 Sample peptide mixture in 80 4 aapi acetonitrile 2 formic acid RONN 5 Sample Wash Binding Buffer 1000 6 Sample Wash Binding Buffer 1 000 7 Sample Wash Washing Buffer 1 000 8 Elution Elution Buffer 150 Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 6 E Perform the Phosphopeptide Enrichment Deep well Plate Protocol 1 Select the protocol using the arrow keys in the instrument keypad and press Start See the KingFisher User Manual for detailed information 2 Slide open the door of the instrument s protective cover Load plates 1 through 8 into the instrument according to the protocol request placing each plate in the same orientation Confirm each action by pressing Start 3 Press Start to initiate the protocol 4 After the samples are processed remove the plates as instructed by the display on the instrument Press Start after removing each plate 5 Press Stop after all plates are removed Transfer samples to a new PCR plate and lyophilize to dryness using a vacuum concentrator For LC MS MS analysis rehydrate each sample in 5 acetonitrile 1 formic acid in water and inject each sample directly fr
17. olonged drying of TiO Magnetic Beads Freezing or excessive drying can cause the beads to lose binding activity For analysis by LC MS MS lyophilize the samples as a final step after processing the beads and reconstitute them in 5 acetonitrile 0 1 formic acid in water The sample fractions not bound to the beads can be analyzed by mass spectrometry however these samples require additional clean up such as drying and C18 desalting Avoid phosphate based buffers during sample preparation because the phosphate anions might interfere with phosphopeptide enrichment Peptides containing acidic residues might reduce phosphopeptide enrichment because the carboxyl groups can interact with the TiO surface Methylation of the carboxyl groups before phosphopeptide enrichment can improve recovery of phosphopeptides See the Additional Information Section for a methylation procedure Concentrate and desalt the sample before phosphopeptide enrichment see the Additional Information Section Procedure for Manual Enrichment of Phosphopeptides A B Additional Materials Required see the Related Products Section for ordering information 96 well magnetic plate separator Sample peptide mixture 50 ml polypropylene conical centrifuge tubes 15 ml polypropylene conical centrifuge tubes Acetonitrile Formic acid Vacuum concentrator with a 96 well plate rotor Prepare the Binding and Washing Buffers Note Prepare buffers just before each exp
18. om the 96 well plate Alternatively for MALDI analysis resuspend samples in o cyano 4 hydroxycinnamic acid MALDI matrix solution and spot onto a MALDI chip Troubleshooting Problem Possible Cause Solution Lack of phosphopeptides identified Dephosphorylation occurred during isolation and processing Include phosphatase inhibitors during sample preparation Poor cell health or improper stimulation to induce phosphorylation events Check cell health and growth and confirm stimulation by Western blot Low amount of phosphorylation events in the sample Increase amount of starting material being processed Interference from inorganic phosphates or highly buffered starting material prevented binding buffer from adjusting sample to the required conditions Use phosphate free buffers dilute sample with binding buffer or change sample preparation method Improper MS instrument setting Use control phosphopeptides e g digested a casein to determine optimal instrument settings Neutral loss of phosphate groups causing poor MS MS phosphopeptide sequencing Perform neutral loss scan and MS experiments or on ETD equipped instruments use ETD fragmentation to preserve phosphorylation events Sample digestion incomplete Monitor sample digestion by SDS PAGE Identification of a large numbers of non phosphorylated peptides Sample contains highly acidic peptides Methylate sample pept
19. oom temperature Note Use prepared 3 N methanolic HCI that is provided in glass ampules e g Sigma Product No 32355 Lyophilize the sample to remove the solvent Dissolve the peptides in up to 1 ml of 80 acetonitrile 0 1 formic acid and proceed to enrichment of phosphopeptides using the Pierce Magnetic TiO Phosphopeptide Enrichment Kit Sample Concentration and Desalting Using Solid Phase Extraction Cartridges or 96 Well Plates Note Sample concentration and desalting is recommended before enrichment with the Pierce Magnetic TiO Phosphopeptide Enrichment Kit To process up to 2 mg of peptides use the Thermo Scientific HyperSep SPE Columns or Thermo Scientific Hypersil C18 96 well Plates see the Related Products Section for ordering information OY as ee Rinse each SPE cartridge or well with one full volume of acetonitrile Rinse each SPE cartridge or well with one full volume of 0 25 TFA in water Repeat this step twice Load peptide digest sample onto SPE cartridge or wells at a flow rate of 1 ml per minute Rinse each SPE cartridge or well with one full volume of 0 25 TFA in water Repeat this step four times Elute the desalted peptide samples in 80 acetonitrile 0 1 formic acid Add formic acid to eluted peptide sample to a final concentration of 2 Add samples directly to TiO beads Pierce Biotechnology PO Box 117 815 968 0747 www thermo com pierce 3747 N Meridian Road Rockford IL 61105 USA 815 968 7316 fax 8
20. sing this number combine equal volumes of acetonitrile and Washing Buffer in a 15 ml polypropylene conical tube and mix to obtain a homogeneous solution Close the tube tightly to prevent acetonitrile evaporation Prepare the TiO Magnetic Beads Note The following protocol is recommended when processing a minimum of mg of peptide mixture The protocol uses 100 ul of 20X TiO Magnetic Beads per sample This volume can be adjusted however a ratio of 1 ul of stock beads to 10 ug of peptide mixture is recommended Optional Rinse all plastic wear to be used such as the 96 well plates three times with acetonitrile to minimize contamination from polymers leaching from the plastics Determine the total number of samples to be processed Multiply the total number of samples plus 0 5 by 100 ul to calculate the total volume of magnetic beads required Place the calculated volume of 20X TiO Magnetic Beads into a 15 ml polypropylene conical tube Note To ensure homogeneity mix the vial of 20X TiO Magnetic Beads thoroughly before use by repeated inversion gentle vortexing or rotating platform Add 900 ul of prepared Binding Buffer per sample 0 5 to the tube Screw the cap onto the tube and invert several times to ensure complete suspension of the beads Set up the plates according to Table 2 which will subsequently be placed into the KingFisher Instrument Table 2 Pipetting instructions for the Phosphopeptide Enrichment using the Microt
Download Pdf Manuals
Related Search
Related Contents
INSTRUCTIONS PC104-386L-2MB PC/104 386SX CPU Module User's Manual Avaya 3.0.0 Telephone User Manual スカパー!HD再生 取扱説明書 1/5 製品名 TPR6712 整理番号 GJ20099 maxpro® vms r300 sp1 - Honeywell Integrated Security Philips AQ 6591/14 User's Manual Instruzioni di Montaggio Copyright © All rights reserved.
Failed to retrieve file