Home

VMware ESX 3.5.0 U5 7.4.0.52 User Manual

image

Contents

1. elxvmwarecorekit lt kit version gt Or elxocmcore esx35 lt kit version gt 3 Type rpm e elxvmwarecorekit lt kit version gt Or rpm e elxocmcore esx35 lt kit version gt Emulex Drivers for VMware ESX 3 5 User Manual Page 5 gt G EMULEX Configuration Introduction You can configure the driver parameters using native ESX tools or Emulex s OneCommand Manager application This section describes how to configure parameters using native ESX tools For a more comprehensive description of ESX tools refer to the vi3_server_config pdf documentation If you have further questions contact a VMware technical support representative Note VMware does not officially support unloading the driver via vmkload_mod u If you must unload the driver contact VMware customer support Emulex recommends using the OneCommand Manager application to set the configuration parameters Refer to the Emulex OneCommand Manager Application User Manual for more information about the utility Note NPIV port creation and deletion are performed by VMware s Infrastructure Client VIC Refer to VMware s Infrastructure Client documentation for more information Note In band management FC based management is not supported on VMware ESX 3 5 servers Use out of band management TCP IP based management to remotely manage adapters on ESX 3 5 servers For the VMware ESX 3 5 Server the firewall on the ESX Server must be opened to
2. Ip SEVERITY Information LOG LOG_FCP LOG_CHK_COND verbose ACTION None required Ipfc_mes0738 Scheduler received Queue Full status from FCP device lt tgt gt lt lun gt DESCRIPTION The scheduler received a Queue Full error status from the specified FCP device DATA 1 qfull_retry_count 2 qfull_retries 3 currentOutstanding 4 maxOutstanding SEVERITY Information LOG LOG_FCP verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 71 gt G EMULEX Ipfc_mes0747 Completed target reset DESCRIPTION Target reset completed DATA 1 tgt_id 2 lun_id 3 Status SEVERITY Information LOG LOG_FCP verbose ACTION None required Ipfc_mes0748 Completed LUN reset DESCRIPTION LUN reset completed DATA 1 tgt_id 2 lun_id 3 Status 4 command frag SEVERITY Information LOG LOG_FCP verbose ACTION None required lpfc_mes0749 Completed abort task set DESCRIPTION Abort task set completed DATA 1 tgt_id 2 lun_id 3 cmpl time mS SEVERITY Information LOG LOG_FCP verbose ACTION None required Ipfc_mes0750 Failed Abort Task Set Data x x x ld DESCRIPTION Abort Task Set completed DATA 1 tgt id 2 lun id 3 timeout mS SEVERITY Error LOG Always ACTION This error could indicate a software driver problem If problems persist report these errors to Technical Support Ipfc_mes0754 SCSI timeout DESCRIPTION An FCP IOCB command was posted to a ring a
3. Syntax error code lt code gt DESCRIPTION A syntax error occurred while parsing WWPN binding configuration information DATA None Detail Binding syntax error codes 0 FC_SYNTAX_OK 1 FC_SYNTAX_OK_BUT_NOT_THIS_BRD 2 FC_SYNTAX_ERR_ASC_CONVERT 3 FC_SYNTAX_ERR_EXP_COLON 4 FC_SYNTAX_ERR_EXP_LPFC 5 FC_SYNTAX_ERR_INV_LPFC_NUM 6 FC_SYNTAX_ERR_EXP_T 7 FC_SYNTAX_ERR_INV_TARGET_NUM 8 FC_SYNTAX_ERR_EXP_D 9 FC_SYNTAX_ERR_INV_DEVICE_NUM 10 FC_SYNTAX_ERR_INV_RRATIO_NUM 11 FC_SYNTAX_ERR_EXP_NULL_TERM SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file Ipfc_mes0431 WWNN binding entry lt num gt Syntax error code lt code gt DESCRIPTION A syntax error occurred while parsing WWNN binding configuration information DATA None Detail Binding syntax error codes 0 FC_SYNTAX_OK 1 FC_SYNTAX_OK_BUT_NOT_THIS_BRD 2 FC_SYNTAX_ERR_ASC_CONVERT 3 FC_SYNTAX_ERR_EXP_COLON 4 FC_SYNTAX_ERR_EXP_LPFC 5 FC_SYNTAX_ERR_INV_LPFC_NUM 6 FC_SYNTAX_ERR_EXP_T 7 FC_SYNTAX_ERR_INV_TARGET_NUM 8 FC_SYNTAX_ERR_EXP_D 9 FC_SYNTAX_ERR_INV_DEVICE_NUM 10 FC_SYNTAX_ERR_INV_RRATIO_NUM 11 FC_SYNTAX_ERR_EXP_NULL_TERM SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file Ipfc_mes0432 WWPN binding entry node table full DESCRIPTION More bindings entries were configured than the driver can handle DATA None SEVERITY Error config LOG
4. 1 port_state 2 fc_flag 3 num_disc_nodes 4 fc_plogi_cnt 5 fc_adisc_cnt 6 fe_map_cnt SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1817 Target d assigned to vpi d DID s WWPN s WWNN s DESCRIPTION Target mapping info for vport DATA 1 Target number 2 vpi number 3 DID lt d_id gt 4 WWPN lt wwpn gt 5 WWNN lt wwnn gt SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1818 Failed to INIT_VPI DESCRIPTION VPI activation failed DATA 1 vpi 2 rc SEVERITY Warning LOG LOG_VPORT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 84 gt G EMULEX Ipfc_mes1819 Rcvd an event with vport not null DESCRIPTION Received an event with the VPort not null DATA 1 event 2 vpi SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1820 ELS Ring rcvd an unexpected Rctl type DESCRIPTION ELS ring received an unexpected RCTL type DATA 1 ELS ring number 2 fh_r_ctl 3 fh_type SEVERITY Warning LOG LOG_VPORT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 85 gt G EMULEX Initialization Events 4500 4599 Ipfc_mes4500 iotag out of range DESCRIPTION The iotag lookup failed because it is outside the allowable range DATA 1 iotag 2 max 3 iocb 7 SEVERITY Error LOG Always ACTION This error may indicate a hardware firmw
5. Always ACTION Make necessary changes to the Ipfc configuration file so that fewer bindings are configured Emulex Drivers for VMware ESX 3 5 User Manual Page 58 gt EMULEX Ipfc_mes0433 WWNN binding entry node table full DESCRIPTION More bindings entries were configured than the driver can handle DATA None SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file so that fewer bindings are configured Ipfc_mes0434 DID binding entry lt num gt Syntax error code lt code gt DESCRIPTION A syntax error occurred while parsing DID binding configuration information DATA None Detail Binding syntax error codes 0 FC_SYNTAX_OK 1 FC_SYNTAX_OK_BUT_NOT_THIS_BRD 2 FC_SYNTAX_ERR_ASC_CONVERT 3 FC_SYNTAX_ERR_EXP_COLON 4 FC_SYNTAX_ERR_EXP_LPFC 5 FC_SYNTAX_ERR_INV_LPFC_NUM 6 FC_SYNTAX_ERR_EXP_T 7 FC_SYNTAX_ERR_INV_TARGET_NUM 8 FC_SYNTAX_ERR_EXP_D 9 FC_SYNTAX_ERR_INV_DEVICE_NUM 10 FC_SYNTAX_ERR_INV_RRATIO_NUM 11 FC_SYNTAX_ERR_EXP_NULL_TERM SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file Ipfc_mes0435 DID binding entry node table full DESCRIPTION More bindings entries were configured than the driver can handle DATA None SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file so that fewer bindings are configured Ipfc_mes0436 Adapter failed to init timeout sta
6. Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 50 gt G EMULEX Ipfc_mes0317 Rsp ring lt ringno gt get iotag lt iotag gt greater then configured max lt fast_iotag gt wd0O lt irsp gt DESCRIPTION The assigned I O iotag is greater than the maximum allowed DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support Ipfc_mes0318 Outstanding I O count for ring lt ringno gt is at max lt fast_iotag gt DESCRIPTION An I O tag cannot be assigned because none are available The maximum number of allowed I Os are currently outstanding DATA None SEVERITY Error LOG Always ACTION This message indicates the adapter HBA I O queue is full Typically this happens when heavy I O is running on a low end 3 digit adapter Emulex suggests you upgrade to a higher end adapter Ipfc_mes0319 The driver issued a READ_SPARAM mbox command to the HBA that failed DESCRIPTION The driver issued a READ_SPARAM mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support Ipfc_mes0320 CLEAR_LA mbxStatus error lt mbxStatus gt hba state lt hba_state gt DESCRIPTIO
7. DATA 1 Event code SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4542 CT Resp iocb timeout DESCRIPTION CT Response IOCB timeout DATA 1 l OCB s iotag 2 tag 3 Nport SEVERITY Information LOG LOG_INIT verbose ACTION None required lpfc_mes4543 CT Resp iocb error DESCRIPTION CT Response IOCB error DATA 1 rc 2 IOCB s iotag 3 tag 4 Nport SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4544 Failed to get the non embedded SGE virtual address gt G EMULEX DESCRIPTION Failed to get the SGE virtual address for the non embedded mailbox command DATA None SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary This is an unlikely error contact Technical Support Emulex Drivers for VMware ESX 3 5 User Manual If this condition persists Page 92 gt G EMULEX Ipfc_mes4545 READ_FCF_RECORD mailbox failed DESCRIPTION Issue READ_FCF_RECORD mailbox returned status failure DATA 1 status 2 add_status SEVERITY Error LOG Always ACTION This is part of the driver s basic discovery process It may be a critical problem as long as at least one of the FCF records reads back successfully However if none of the FCF records reads back successfully reboot the system as necessary If the problem persists contact Technical Support Ipfc_mes4546 FCP complete error DESCRIPTION FCP work queue com
8. DESCRIPTION The driver invoked an HBA reset DATA 1 port_state 2 sli_flag SEVERITY Information LOG LOG_INIT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 93 gt G EMULEX Ipfc_mes4551 Performing PCI function reset DESCRIPTION The driver invoked a PCI function reset DATA None SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4552 Restart HBA DESCRIPTION The driver invoked an HBA restart DATA 1 port_state 2 sli_flag SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4553 Failed to allocate connection table entry DESCRIPTION Failed to allocate connection table entry DATA None SEVERITY Error LOG Always ACTION It may not be a critical problem if the driver failed to allocate memory for some of the FCF connection table entries for the driver discover process However failure of the driver to allocate kernel memory may indicate a serious problem Reboot the system if necessary Ipfc_mes4554 Config region 23 has bad signature DESCRIPTION Config region 23 has bad signature DATA None SEVERITY Error LOG Always ACTION It may not be a critical problem for the driver and HBA s normal operation if configure region contains a bad signature However it may result in some of the management stack functionality not working properly to manage the HBA Try to re configure the device configure region 23 i
9. DSM OUT vpi lt vpi gt state lt rc gt on NPort lt nlp_DID gt DESCRIPTION The driver Discovery State Machine completed processing an event DATA 1 nlp_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0213 Reassign scsi id lt sid gt to NPort lt nlp_DID gt DESCRIPTION A previously bound FCP Target has been rediscovered and reassigned a SCSI ID DATA 1 nlp_bind_type 2 nlp_flag 3 nlp_state 4 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 36 gt G EMULEX Ipfc_mes0214 RSCN received DESCRIPTION An RSCN ELS command was received from a fabric DATA 1 fc_flag 2 i 3 Ip 4 fc_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0215 RSCN processed DESCRIPTION An RSCN ELS command was received from a fabric and processed DATA 1 fc_flag 2 cnt 3 fe_rscn_id_cnt 4 fc_ffstate SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0216 Assign scandown scsi id lt sid gt to NPort lt nlp_DID gt DESCRIPTION A SCSI ID is assigned due to BIND_ALPA DATA 1 nlp_bind_type 2 nlp_flag 3 nlp_state 4 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational Ipfc_m
10. Information LOG LOG_FCP verbose ACTION Check the state of the target in question Ipfc_mes0703 Issue LUN Reset to TGT lt num gt LUN lt num gt DESCRIPTION The SCSI layer detected that it must abort all I O to a specific device This results in an FCP Task Management command to abort the I O in progress DATA 1 scsi_id 2 lun_id 3 rpi 4 flags SEVERITY Information LOG LOG_FCP verbose ACTION Check the state of the device in question Ipfc_mes0O712 SCSI layer issued abort device DESCRIPTION The SCSI layer is requesting the driver to abort I O to a specific device DATA 1 target 2 lun 3 lpfc_cmd 4 cur_iocbq SEVERITY Error LOG Always ACTION Check the state of the device in question Ipfc_mes0714 SCSI layer issued bus reset DESCRIPTION The SCSI layer is requesting the driver to abort all I Os to all targets on this HBA DATA 1 tgt 2 lun 3 rc success failure SEVERITY Error LOG Always ACTION Check the state of the targets in question Ipfc_mes0716 FCP Readl Underrun expected lt len gt residual lt resid gt DESCRIPTION An FCP device provided less data than was requested DATA 1 fcpi_parm 2 cmnd 0 3 underflow SEVERITY Information LOG LOG_FCP verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 70 gt G EMULEX Ipfc_mes0717 FCP command lt cmd gt residual underrun converted to error DESCRIPTION The driver converted this un
11. Ipfc_mes0901 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on the DID DATA 1 nlp 2 nlp_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0902 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on the DID DATA 1 nlp 2 nlp_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0903 Add scsiid lt sid gt to BIND list DESCRIPTION The driver is putting the node table entry on the binding list DATA 1 bind_cnt 2 nlp_DID 3 bind_type 4 blp SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0904 Add NPort lt did gt to PLOGI list on vpi lt vpi gt DESCRIPTION The driver is putting the node table entry on the PLOGI list DATA 1 plogi_cnt 2 blp SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0905 Add NPort lt did gt to ADISC list DESCRIPTION The driver is putting the node table entry on the ADISC list DATA 1 adisc_cnt 2 blp SEVERITY Information LOG LOG_NODE verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 74 gt G EMULEX Ipfc_mes0906 Add NPort lt did gt to UNMAP list DESCRIPTION The driver is putting the node table entry on the unmap list DATA 1 unma
12. None required Emulex Drivers for VMware ESX 3 5 User Manual Page 75 gt G EMULEX Ipfc_mes0929 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on the DID DATA 1 nlp 2 nip_DID 3 nlp_flag 4 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0930 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on the DID DATA 1 nlp 2 nlp_DID 3 nlp_flag 4 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0931 FIND node DID bind DESCRIPTION The driver is searching for a node table entry on the binding list based on the DID DATA 1 nlp 2 nlp_DID 3 nlp_flag 4 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0932 FIND node did lt did gt NOT FOUND on vpi lt vpi gt DESCRIPTION The driver searched for a node table entry based on the DID and did not find the entry DATA 1 order SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0933 lt func gt ALLOC node did lt did gt on vpi lt vpi gt DESCRIPTION The driver allocated a node table entry based on the DID and did not find the entry DATA 1 func 2 did 3 vpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0934
13. 1 fe_ns_retry 2 fe_max_ns_retry SEVERITY Error LOG Always ACTION None required The driver should recover from this event Ipfc_mes0232 Continue discovery with lt num_disc_nodes gt PLOGIs to go DESCRIPTION Device discovery is in progress DATA 1 fc_plogi_cnt 2 fc_flag 3 vport gt port_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0234 ReDiscovery RSCN DESCRIPTION The number type of RSCNs has forced the driver to go to the nameserver and re discover all NPorts DATA 1 fe_defer_rscn q_cnt 2 fc_flag 3 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 39 gt G EMULEX Ipfc_mes0235 Deferred RSCN DESCRIPTION The driver has received multiple RSCNs and has deferred the processing of the most recent RSCN DATA 1 fc_defer_rscn q_cnt 2 fc_flag 3 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0236 NameServer req DESCRIPTION The driver is issuing a NameServer request to the fabric DATA 1 cmdcode 2 fc_flag 3 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0237 Pending Link Event during Discovery DESCRIPTION Received link event during discovery Causes discovery restart DATA 1 hba_st
14. CT ABTS context DATA 1 oxid 2 SID SEVERITY Error LOG Always ACTION None required The received unsolicited event ABTS will be ignored Emulex Drivers for VMware ESX 3 5 User Manual Page 78 gt G EMULEX Link Events 1300 1399 Ipfc_mes1300 Re establishing Link timer expired DESCRIPTION The driver detected a condition where it had to re initialize the link DATA 1 fc_flag 2 fc_ffstate SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network Ipfc_mes1301 Re establishing Link DESCRIPTION The driver detected a condition in which it had to re initialize the link DATA 1 status 2 status1 3 status2 SEVERITY Information LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network Ipfc_mes1302 Reset link speed to auto 1G HBA cfg d for 2G DESCRIPTION The driver is reinitializing the link speed to auto detect DATA 1 current link speed SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION None required Ipfc_mes1303 Link Up Event lt eventTag gt received DESCRIPTION A link up event was received It is also possible for multiple link events to be received together DATA 1 fc_eventTag 2 granted_AL_PA 3 UlnkSpeed 4 alpa_map 0 DETAIL If link events received log 1 last event number received 2 ALPA granted 3 Lin
15. DATA 1 vport DID 2 vport vpi 3 vport state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes131 Fabric LOGO Completes DESCRIPTION The vport s fabric LOGO failed to complete successfully DATA 1 vport DID 2 vport VPI 3 ulpStatus 4 iocb word 4 SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes132 Fabric acknowledging NPIV lt 0 1 gt DESCRIPTION If the fabric supports NPIV a 1 is printed 0 if not DATA 1 max vpi SEVERITY Information LOG LOG ELS verbose ACTION No action needed informational However if the fabric NPIV support is incorrect contact Emulex Technical Support Ipfc_mes133 FLOGI failure DESCRIPTION An ELS FLOGI command timed out and CLEAR_LA cannot be issued DATA mbox error reason code 0 means no resources SEVERITY error LOG LOG ELS verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 34 gt G EMULEX Link Discovery Events 0200 0299 Ipfc_mes0200 CONFIG_LINK bad hba state lt hba_state gt DESCRIPTION A CONFIG_LINK mbox command completed and the driver was not in the right state DATA None SEVERITY Error LOG Always ACTION Software driver error If this problem persists report these errors to Technical Support Ipfc_mes0201 Abort outstanding I O on NPort lt nip_DID gt DESCRIPTION All outstanding I Os are cleaned up
16. LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0305 Mbox cmd cmpl error RETRYing DESCRIPTION A mailbox command completed with an error status that causes the driver to reissue the mailbox command DATA 1 mbxCommand 2 mbxStatus 3 word1 4 hba_state SEVERITY Information LOG LOG_MBOX verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 48 gt G EMULEX Ipfc_mes0306 CONFIG_LINK mbxStatus error lt mbxStatus gt HBA state lt hba_state gt DESCRIPTION The driver issued a CONFIG_LINK mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support Ipfc_mes0307 Mailbox cmd lt cmd gt cmpl lt mbox_cmpl gt lt pmbox gt lt varWord gt lt varWord gt lt varWord gt lt varWord gt lt varWord gt lt varWord gt lt varWord gt lt varWord gt DESCRIPTION A mailbox command completed DATA IOCTL opcode varWord 0 varWord 7 SEVERITY Information LOG LOG_MBOxX verbose ACTION No action needed informational Ipfc_mes0308 Mbox cmd issue BUSY DESCRIPTION The driver attempted to issue a mailbox command while the mailbox was busy processing the previous command The processing of the new command will be deferred until the mailbox becom
17. SEVERITY Information LOG LOG_INIT verbose ACTION Check the FW revision and contact Technical Support Ipfc_mes0403 Max DMA Length mailbox command successful DESCRIPTION The driver successfully set the max DMA length DATA 1 mbxCommand 2 mbxStatus SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational Ipfc_mes0404 HBA setup complete SLI rev lt sli_rev gt DESCRIPTION The driver finished configuring the HBA Final setup values are written to the console DATA 1 max_vpi 2 sli 3_options SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational Ipfc_mes0405 Service Level Interface SLI selected DESCRIPTION A CONFIG_PORT SLI mailbox command was issued DATA None SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 56 gt G EMULEX Ipfc_mes0406 HBA Heartbeat disabled DESCRIPTION The driver will issue heartbeat messages to the HBA DATA None SEVERITY Information LOG LOG_INIT non maskable ACTION No action needed informational Ipfc_mes0407 HBA reset disabled DESCRIPTION On error the driver will not reset the HBA DATA None SEVERITY Information LOG LOG_INIT non maskable ACTION No action needed informational Ipfc_mes0410 Cannot find virtual addr for mapped buf on ring lt num gt DESCRIPTION The driver cannot find the specif
18. Support Ipfc_mes0496 SLI_FUNCTION_RESET mailbox failed DESCRIPTION Mailbox command to reset function failed DATA 1 shdr_status 2 shdr_add_status 3 rc SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0497 Failure HBA POST DESCRIPTION HBA POST failure DATA 1 sta_reg 2 perr 3 sfi 4 nip 5 ipc 6 xrom 7 dl 8 pstatus SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 67 gt G EMULEX Ipfc_mes0498 Device Info ChipType lt val gt SLIRev lt val gt FeatureL1 lt val gt FeatureL2 lt val gt DESCRIPTION Device information reported by adapter DATA None SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational Ipfc_mes0499 HBA Unrecoverable error DESCRIPTION HBA POST failure DATA 1 uerr_lo_reg 2 uerr_hi_reg 3 ue_mask_lo_reg 4 ue_mask_hi_reg SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 68 IP Log Events 0600 0699 Ipfc_mesO0600 FARP RSP received from DID lt did gt DESCRIPTION A FARP ELS command re
19. best performance for OneConnect UCNAs With a multi core CPU pinning a VM and the MSI X vector of the OneConnect driver interface configured in that VM to two cores sharing an L2 cache provides the best performance Emulex Drivers for VMware ESX 3 5 User Manual Page 10 gt G EMULEX For example in a quad core Xeon CPUO and CPU1 share a 4MB L2 cache If vmnicO7 is configured in VM1 for the best performance pin VM1 to CPUO and the IRQ corresponding to vmnic07 to CPU1 To pin a VM to a CPU in the VI Client 1 Power OFF the VM 2 Click Edit Settings for that VM then select the Resources tab 3 Select Advanced CPU in the left pane 4 Inthe Scheduling Affinity frame select the CPU to pin it to 5 Power ON the VM To pin an IRQ vector on a CPU run the following command in the console operating system echo move lt IRQ NO gt lt CPU ID gt gt proc vmware intr tracker You can find the IRQ NO corresponding to a vmnic by running cat proc vmware interrupts To see all IRQ Vectors and the CPU they are pinned to run cat proc vmware intr tracker Emulex LPFC Driver Configuration Parameters All adapter specific LPFC driver parameters have an IpfcX_ prefix where X is the driver instance number for example setting lpfcO_lun_queue_depth 20 makes 20 the default number of maximum commands which can be sent to a single logical unit disk for lpfc instance 0 Dynamic parameters do not require a system reboot for
20. compatible firmware versions see the Downloads page for the specific adapter Known Issues Refer to the product release notes for the latest information Emulex Drivers for VMware ESX 3 5 User Manual Page 2 gt G EMULEX Installing the Drivers There are three Emulex drivers FC FCoE NIC and iSCSI available through the Emulex Web site Note The NIC driver must be installed to manage OneConnect FCoE iSCSI or NIC UCNAs using the OneCommand Manager application To install the Emulex drivers for VMware 1 Install a supported Emulex adapter in the system Refer to the adapter s Installation manual for specific hardware installation instructions 2 Remove any previously installed drivers and or utilities such as HBAnyware that were installed from the Emulex CD or downloaded from the Emulex Web site before proceeding Refer to Uninstalling the Drivers on page 4 and Uninstalling Older HBAnyware Kits on VMware on page 5 for more information 3 Download the specific driver kit from the Emulex Web site Log on to the ESX Server host Install the specific driver binary RPM file e For the FC FCoE driver type rpm i VMware esx drivers scsi lpfc elx v740 350 lt driver version gt 001 1386 rpm e For the NIC driver type rpm i VMware esx drivers net be2net 2 101 lt driver version gt i386 rpm e For the iSCSI driver type rpm i VMware esx drivers be2iscsi 2 101 lt driver version gt i386 rpm Note I
21. events DATA 1 mailbox response status SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0457 Adapter Hardware Error DESCRIPTION The driver received an interrupt indicating a possible hardware problem Data 1 status 2 status1 3 status2 SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0458 Bring adapter online DESCRIPTION The FC driver has received a request to bring the adapter online This may occur when running Iputil DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes0459 HBA heartbeat failure DESCRIPTION The HBA has not responded to a heartbeat command in the time allotted DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 62 gt EMULEX Ipfc_mes0460 Bring adapter offline DESCRIPTION The FC driver has received a request to bring the adapter offline This may occur when running Iputil DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes0462 Too many cmd rsp ring entries in SLI 2 SLIM DESCRIPTION The configuration
22. explains many of these circumstances and offers one or more workarounds for each situation Unusual Situations and Their Resolutions General Situations Table 3 General Situations Situation Resolution Vports created on an adapter are not re created if the adapter is replaced VPorts are assigned to a specific adapter only They cannot be transferred to a new adapter You must create new VPorts if an adapter is replaced NPIV configuration not working as expected Check for a message similar to the following message in the VMkernel log The Adapter failed to init retry in SLI 2 mode This error could indicate a hardware or firmware problem Try reflashing your up to date FW or upgrade to the latest firmware If this problem persists report the error to Technical Support Emulex PCI X adapters and PCI X bridge chipsets DMA size transfer issue Sun Emulex and VMware have worked together to identify an issue with certain PCI X bridge chipsets The issue is currently limited to Sun Fire X4100 and X4200 servers Note The Sun Fire X4100 M2 and X4200 M2 servers are not affected The issue is centered around the size of a DMA transfer that works repeatedly and successfully from the AMD chipset versus the maximum DMA transfer size supported by the adapter The primary symptoms are hung VMs and a large number of SCSI commands timed out by the Emulex driver If you are experiencing these symptoms
23. from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0126 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0127 ELS timeout DESCRIPTION An ELS IOCB command was posted to a ring and did not complete within ULP timeout seconds DATA 1 elscmd 2 did 3 ulpcommand 4 iotag SEVERITY Error LOG Always ACTION If no ELS command is going through the adapter reboot the system If problem persists contact Technical Support Ipfc_mes0128 FDISC failed DESCRIPTION An FDISC failed DATA None SEVERITY Error LOG Always ACTION Make sure the switch supports NPIV If problem persists contact Technical Support Ipfc_mes0129 FDISC succeeded DESCRIPTION An FDISC succeeded DATA 1 DID SEVERITY Information LOG LOG_ELS verbose ACTION No action need informational Emulex Drivers for VMware ESX 3 5 User Manual Page 33 gt G EMULEX Ipfc_mes0130 Xmit Fabric LOGO ELS command to fabric DESCRIPTION A vport is sending a LOGO for its FDISC to the switch
24. gt G EMULEX Emulex Drivers for VMware ESX 3 5 FC and FCoE version 7 4 0 52 NIC version 2 101 374 0 iSCSI version 2 101 374 0 User Manual One Network One Company P004437 01A Rev A Connect with Emulex gt G EMULEX Copyright 2003 2010 Emulex All rights reserved worldwide No part of this document may be reproduced by any means or translated to any electronic medium without the prior written consent of Emulex Information furnished by Emulex is believed to be accurate and reliable However no responsibility is assumed by Emulex for its use or for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent copyright or related rights of Emulex Emulex the Emulex logo AutoPilot Installer AutoPilot Manager BlockGuard Connectivity Continuum Convergenomics Emulex Corporation Connect Emulex Corporation Secure EZPilot FibreSpy HBAnyware InSpeed LightPulse MultiPulse OneCommand OneConnect One Network One Company One Network One Company Connect with Emulex SBOD SLI and VEngine are trademarks of Emulex All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations Emulex provides this manual as is without any warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitnes
25. hexadecimal conversion failed The output buffer byte size is less than half of the input byte count Every two input characters bytes require one output byte DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver problem If the problem persists report the error to Technical Support Ipfc_mes1213 Convert ASC to hex Input char seq not ASC hex DESCRIPTION The ASCII hexadecimal input string contains a non ASCII hexadecimal character DATA None SEVERITY Error configuration LOG Always ACTION Make necessary changes to the Ipfc configuration file Emulex Drivers for VMware ESX 3 5 User Manual Page 77 gt G EMULEX lIpfc_mes1214 Xmit CT ABTS ACC DESCRIPTION Information on transmit CT ABTS ACC DATA 1 bls_rsp command 2 oxid 3 sid 4 hba_state SEVERITY Information LOG LOG_MISC verbose ACTION None required Ipfe_mes1215 Ignoring unsolicited CT No HBQ DESCRIPTION Information on the CT ABTS buffer when there is no HBQ associated with it DATA 1 iocb_ulpStatus SEVERITY Information LOG LOG_MISC verbose ACTION None required Ipfc_mes1216 Ignoring unsolicited CT No HBQ DESCRIPTION Information on the CT ABTS buffer when there is no HBQ associated with it DATA 1 size of HBQ buffer 2 iocb_ulpStatus SEVERITY Information LOG LOG_MISC verbose ACTION None required Ipfe_mes1217 Find ndlp returned NULL DESCRIPTION Find NDLP returned NULL to a
26. lt func gt FREE node did lt did gt on vpi lt vpi gt DESCRIPTION The driver searched for a node table entry based on the DID and did not find the entry DATA 1 did 2 rpi 3 vpi 4 flag SEVERITY Information LOG LOG_NODE verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 76 gt G EMULEX Miscellaneous Events 1200 1299 Ipfc_mes1206 Dropped frame rctl lt str gt type lt str gt DESCRIPTION Dropped an unsolicited frame DATA None SEVERITY Information LOG LOG_MISC verbose ACTION None required Ipfc_mes1207 Received frame rctl lt str gt type lt str gt DESCRIPTION Received an unsolicited frame DATA None SEVERITY Information LOG LOG_MISC verbose ACTION None required Ipfc_mes1208 C_CT request error DESCRIPTION The CT response returned more data than the user buffer could hold DATA 1 dfc_flag 2 4096 SEVERITY Information LOG LOG_MISC verbose ACTION Modify the user application issuing a CT request to allow for a larger response buffer Ipfc_mes1210 Convert ASC to hex Input byte cnt lt 1 DESCRIPTION ASCII string to hexadecimal conversion failed The input byte count is less than 1 DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver problem If the problem persists report the error to Technical Support Ipfc_mes1212 Convert ASC to hex Output buffer too small DESCRIPTION ASCII string to
27. on the specified remote NPort DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0202 Start Discovery on vpi lt vpi gt hba state lt hba_state gt DESCRIPTION Device discovery rediscovery after FLOGI FAN or RSCN has started DATA 1 tmo 2 fc_plogi_cnt 3 fc_adisc_cnt 4 fc_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0204 Create SCSI Target lt tgt gt DESCRIPTION A mapped FCP target was discovered and the driver has allocated resources for it DATA None SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational Ipfc_mes0205 Create SCSI LUN lt lun gt on Target lt tgt gt DESCRIPTION A LUN on a mapped FCP target was discovered and the driver has allocated resources for it DATA None SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational lpfc_mes0206 Report Lun completes on NPort lt nlp_DID gt DESCRIPTION The driver issued a REPORT_LUN SCSI command to a FCP target and it completed DATA 1 ulpStatus 2 rspStatus2 3 rspStatus3 4 nlp_failMask SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 35 gt G EMULEX Ipfc_mes0207 Issue Report L
28. rc SEVERITY Warning LOG LOG_MBOX LOG_SLI verbose ACTION None required Ipfc_mes4512 Cannot issue sync mailbox cmd lt opcode gt DESCRIPTION Synchronous mailbox command cannot be issued DATA 1 vpi 2 rc SEVERITY Warning LOG LOG_MBOX LOG_SLI verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 87 gt G EMULEX Ipfc_mes4513 ELS WQE has a different Queue Id DESCRIPTION The event ID consumed by the adapter does not match the intended ELS WQ ID DATA 1 Event Queue Id 2 ELS WQ Id SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4514 Invalid Completion event code DESCRIPTION An invalid slow path completion event was received DATA 1 majorcode 2 minorcode SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4515 Invalid Completion Queue Id DESCRIPTION An invalid Completion Queue ID was received DATA 1 Completion Queue ID received from the firmware SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4516 Fast path WQE has a different Queue Id DESCRIPTION The event ID consumed by the adapter does not match the
29. verbose ACTION No action needed informational Ipfc_mes0121 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0122 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0123 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 32 gt G EMULEX Ipfc_mes0124 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0125 PLOGI chkparm OK DESCRIPTION Received a PLOGI
30. version 7 4 or later must be loaded Note In band management FC based management is not supported on VMware ESX 3 5 servers Use out of band management TCP IP based management to remotely manage adapters on ESX 3 5 servers For VMware ESX 3 5 servers the firewall on the ESX Server must be opened to man age systems remotely using TCP IP For instructions see Opening the ESX Server Firewall on page 3 Procedures To install the OneCommand Manager application CLI 1 Log on to the ESX Server host 2 Copy the elxocmcore esxNN lt kit version gt i386 rpm file to a directory on the install machine 3 CD to the directory to which you copied the rpm file 4 Install the rpm Type rpm U elxocmcore esx35 lt kit version gt i386 rpm The rpm contents are installed in usr sbin nbanyware The OneCommand Manager application CLI is also located in this directory VMware Systems with an Existing HBAnyware CLI Kit Installed To install the OneCommand Manager application CLI on a VMware system with an existing HBAnyware CLI installed 1 Install the RPM by entering the following command all on one line rpm U elxocmcore esx35 lt kit version gt i386 rpm Emulex Drivers for VMware ESX 3 5 User Manual Page 4 gt G EMULEX Uninstalling Older HBAnyware Kits on VMware To uninstall an older HBAnyware Kit on VMware 1 Log on to the ESX Server host 2 Type rpm qa grep elx and locate either of the following rpm files
31. ATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0476 RQ_CREATE mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be initialized with the specified count DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0477 EQ DESTROY mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be destroyed mailbox command failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0478 CQ DESTROY mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be destroyed mailbox command failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 65 gt G EMULEX Ipfc_mes0479 MQ_DESTROY mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be destroyed mailbox command failed DATA None SEVERIT
32. CTL buffer exceeded the BladeEngine s firmware limit Following this error log entry the next entry will indicate the IOCTL opcode and the payload length requested The be2iscsi driver detected an error during offloading the iSCSI connection The operation will be retried again Following this error log entry the next entry will indicate the session handle and the BladeEngine firmware error code This error may indicate an incorrect configuration option for the OneConnect iSCSI driver It may also indicate a low memory condition This may indicate a target is in error or may point to transient network connectivity issues It may also indicate a OneConnect driver firmware error 0x12990013 The be2iscsi driver did not receive an iSCSI command window update up to 25 seconds during I O operations Following this error log entry the next entry will indicate the session handle where this error occurred The beiscsi driver will trigger a session recovery on the session and continue Check for any errors reported at the target The Emulex iSCSI initiator is only supported with certified targets Verify that the iSCSI target is certified by Emulex see the Emulex Web site Check for software updates at the target vendor s website and the Emulex Web site If the above fails contact Emulex technical support Emulex Drivers for VMware ESX 3 5 User Manual Page 22 gt G EMULEX Table 7
33. Check remote NPort for potential problem Ipfc_mes0O116 Xmit ELS command lt elsCmd gt SID lt sid gt DID lt did gt on vpi lt vpi gt DESCRIPTION Xmit ELS command to remote NPort DATA 1 binfo gt fc_ffstate 2 ulpContext SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0O117 Xmit ELS response lt elsCmd gt SID lt sid gt DID lt did gt on vpi lt vpi gt DESCRIPTION Xmit ELS response to remote NPort DATA 1 size 2 ulpContext SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 31 gt G EMULEX Ipfc_mes0O118 Xmit CT response on exchange lt xid gt DESCRIPTION Xmit a CT response on the appropriate exchange DATA 1 ulploTag 2 vport_state 3 nport SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0119 Issue GEN REQ IOCB for NPort lt did gt DESCRIPTION Issue a GEN REQ IOCB for remote NPort These are typically used for CT requests DATA 1 ulploTag 2 fc_ffstate 3 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0120 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS
34. D on switch The active port of the OneConnect UCNA changed and the change was triggered by a VLD message from the switch The current link status follows this message Information Active port changed due to port link status change The active port of the OneConnect UCNA changed and the change was triggered by a change in the link status of the one of the two ports of the OneConnect UCNA This could be due to a cable being connected or disconnected on one of the ports or one of the ports failing The current link status follows this message Information Link status update There was a change in the link status There is no change in the active port This could be due to a cable being connected or disconnected on one of the ports or one of the ports failing The current link status follows this message Information Link Properties for vmnic lt D gt Both ports are down An informational message that both ports of the OneConnect are down Retrieving ESX Server iSCSI Error Log Codes For ESX systems the OneConnect iSCSI be2iscsi driver generates error codes to the Iyar log vmkernel log file The vmkernel log file is an ASCII text file and can be viewed and searched with a text editor such as vi The vmkernel log file is automatically rotated as it gets larger and the rotated log files are named vmkernel x where x is an integer To search the log file for error messages at the command promp
35. ESX Server iSCSI Error Log Code Entries Continued Message Id Message Recommended Resolution 0x127b0012 0x12790006 The be2iscsi driver received an invalid iSCSI Command Sequence Number update from the target Following this error log entry the next three entries will indicate the session handle and the iSCSI parameters MaxCmdSN and ExpCmdsSN respectively A connection to the target was lost fora period exceeding the Extended Timeout ETO The error log entry immediately following this entry will indicate the session ID of the target that lost the connection There will be event log entries from the disk subsystem indicating that the drives were lost If any I Os were in progress the system may see I O errors or failures Check for any errors reported at the target The Emulex iSCSI initiator is only supported with certified targets Verify that the iSCSI target is certified by Emulex see the Emulex Web site Check for software updates at the target vendor s Web site and the Emulex Web site If the above fails contact Emulex technical support Check the connection to the target or the state of the target device If the target is made available any sessions that existed previously are reestablished and the devices are available for I O 0x11990007 The be2iscsi driver received a Task Management Function that is not supported and rejected this request The error log entry immed
36. LOG LOG_INIT verbose ACTION None required lpfc_mes4563 LPFC create port vmk_fc_attach_transport failed DESCRIPTION The driver failed to attach to the FC transport layer DATA None SEVERITY Error LOG Always ACTION Reboot the system If problems persist contact Technical Support Ipfc_mes4564 Clear Virtual Link Received for lt VPI gt lt tag gt DESCRIPTION A Clear Virtual Link event was received DATA None SEVERITY Error LOG Always ACTION If numerous link events are occurring check physical connections to Fibre Channel network Ipfc_mes4565 READ_FCF_RECORD indicates empty FCF table DESCRIPTION The firmware was unable to find FCF_RECORD DATA None SEVERITY Error LOG Always ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 96
37. N The driver issued a CLEAR_LA mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support Ipfc_mes0321 Unknown IOCB command DESCRIPTION Received an unknown IOCB command completion DATA 1 ulpCommand 2 ulpStatus 3 ulploTag 4 ulpContext SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If these problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 51 gt G EMULEX Ipfc_mes0322 Ring lt ringno gt handler unexpected completion loTag lt loTag gt DESCRIPTION The driver could not find a matching command for the completion received on the specified ring DATA 1 ulpStatus 2 ulpWord 4 3 ulpCommand 4 ulpContext SEVERITY Warning LOG LPFC_SLI verbose ACTION This warning is benign during ELS disturbances and unexpected for FCP I O In the absence of any SAN disturbances this error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0323 Unknown Mailbox command lt cmd gt Cmpl DESCRIPTION An unknown mailbox command completed DATA 1 Mailbox Command 2 mbStatus SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors
38. ON Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0273 Allocated DMA memory size d is less than the requested DMA memory size DESCRIPTION Failed to allocate DMA memory for issuing READ_FCF mailbox command DATA 1 Allocated DMA memory size 2 Requested DMA memory size SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0274 Failed to get the non embedded SGE virtual address DESCRIPTION Failed to get the SGE virtual address for the non embedded mailbox command DATA None SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary This is an unlikely error If this condition persists contact Emulex Technical Support Ipfc_mes0275 Failed to create mbox command for READ_FCF cmd DESCRIPTION Failed to construct READ_FCF mailbox command for discovery data DATA None SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0276 Failed to create mbox command for READ_FCF cmd DESCRIPTION Failed to construct READ _FCF mailbox command for management plane query DATA None SEVERITY Error LOG Always ACTION This is not part of the driver basic discovery process and only affects the management stack query to obtain FCF ent
39. ON Outdated firmware was detected during initialization DATA 1 read_rev_reset SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem Update the firmware If the problem persists report the error to Technical Support Ipfc_mes0441 VPD not present on adapter mbxCmd lt cmd gt DUMP VPD mbxStatus lt status gt DESCRIPTION The DUMP_VPD mailbox command failed DATA None SEVERITY Information LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0442 Adapter failed to init mbxCmd lt cmd gt CONFIG_PORT mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_PORT mailbox command DATA 1 hbainit SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support lpfc_mes0443 Failed to attach to Ipfc adapter bus lt bus gt device lt device gt irq lt irq gt DESCRIPTION An Ipfc adapter was found in the PCI config but the Ipfc driver failed to attach DATA 1 bus 2 device 3 irq SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 60 gt G EMULEX Ipfc_mes0446 Adapter failed t
40. Port 1 links were down for a period exceeding the Link Down Timeout LDTO If the initiator has connection to the target there will be event log entries from the disk subsystem indicating that the drives were lost If any I Os were in progress the system may see I O errors or failures Check the links to the OneConnect UCNA If the link is reestablished any sessions that existed previously are reestablished and the devices are available for I O 0x11800003 Both Port 0 and Port 1 links are down Check the links to the OneConnect UCNA Emulex Drivers for VMware ESX 3 5 User Manual Page 24 gt G EMULEX Additional ESX Server iSCSI Driver Messages Messages similar to the following ESX Server VMware ESX 3 5 error messages are returned when you specify illegal options when loading the driver WARNING dic value d out of range Valid Range is 0 1 Using Default Value 1 WARNING eto value Using Default Value 30 d out of range Valid Range is 0 30 WARNING ldto value d out of range Valid Range is 0 30 Using DefaultValue 20 WARNING ios _per_ ctrl value d out of range Valid Range is 1 512 Using Default Value 512 WARNING max_io_ size value d out of range Valid Range is 4 256 KByte Using Default Value 256 WARNING tmf reset value d out of range Valid Range is 1 3 Using Default Value 1 WARNING ddm value d o
41. RY DIx 0200 0299 0x2 Link discovery events LOG_MBOX MBx 0300 0399 0x4 Mailbox and SLI events LOG_SLI LOG_INIT INx 0400 0499 0x8 Initialization events Future 0500 0599 LOG_IP 0600 0699 IP Log events LOG_FCP FPx 0700 0799 0x40 FCP traffic history Future 0800 0899 LOG_NODE NDx 0900 0999 0x80 Node table events Reserved 1000 1099 0x100 Reserved TMx 1100 1199 0x200 LOG_MISC MIx 1200 1299 0x400 Miscellaneous events LOG_LINK_EVENT LKx 1300 1399 0x10 Link and FCoE events FCoE Future 1400 1499 LOG_LIBDFC 10x 1600 1699 0x2000 IOCTL events LOG_VPORT VPx 1800 1899 0x4000 Vport events LOG_INIT 4500 4599 Initialization events LOG_ALL_MSG Oxffff Log all messages Emulex Drivers for VMware ESX 3 5 User Manual Page 27 gt G EMULEX Message Log Example The following is an example of a LOG message Jul 12 16 30 26 lt node gt kernel lpfc0 0234 DIi Device Discovery completes In the above LOG message e IpfcO identifies the LOG message as coming from EMULEX adapter0 e 0234 identifies the LOG message number e Dli identifies the LOG message as a DISCOVERY DI INFORMATION i message Note If the word Data is present in a LOG message any information to the right of Data is intended for Emulex technical support engineering use only Emulex Drivers for VMware ESX 3 5 User Manual Page 28 gt G EMULEX ELS Events 0100 0199 Ipfc_mesO100 FLOGI failure DESCRIPTION An ELS FLOGI command that was se
42. S A AA A A A A 2 Installing the Drivers sissi a 3 Opening the ESX Server Firewall ccccesccecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaaaaaeeeeeeeeas 3 Uninstalling the Drivers ccc ccccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeetetes 4 Installing the OneCommand Manager Application CLl 4 New VMware Systems cccccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeetneas 4 VMware Systems with an Existing HBAnyware CLI Kit Installed e 4 Uninstalling Older HBAnyware Kits ON VMware cccccceceeeeeeeeeeeeteeeeetees 5 Configuration sisian hie diva ded ha aie ea dads hale lala di ded aa Saale de dete ae eden 6 INUPOGUCU OM cacccesccere cece tec E cece RecE PECL Secor 6 LPFC Driver Configuration Methods Using Native ESX Tools ee 6 Permanent Configuration Methods sssseeseeeeeeeeeeeeeeeeeeteeettetteeeeeeeeeees 6 Dynamically Add LUNs and Targets ee i ii iiiiiierieererees 8 Creating a Fibre Channel Remote Boot Disk ceeeeeeeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeteeees 8 VirtualiZation Features orici a EE 8 Configuring Multiple NIC Interfaces with OneConnect UCNAS se 8 Enabling the NetQueue Feature ccccseecereeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 8 How ESX Server Creates and Names Interfaces ccccccccceeeeeeenteeeeeeees 8 Configuring VLANS 00 En En En nn In nn NANA NAA NANA NAN N 9 Configuring Network Heap Size in ESX Server ceeee
43. Status lt status gt DESCRIPTION Adapter initialization failed when issuing CONFIG_HBQ mailbox command DATA 1 mbx_Command 2 mbx_Status 3 hbq entry SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0453 Adapter failed to init mbxCmd lt cmd gt READ_CONFIG mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing a READ_CONFIG mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 61 gt G EMULEX Ipfc_mes0454 Adapter failed to init mbxCmd lt cmd gt INIT_LINK mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing an INIT_LINK mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0455 Vital Product DESCRIPTION Vital product data VPD contained in the HBA flash DATA 1 vpd 0 2 vpd 1 3 vpd 2 4 vpd 3 SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational Ipfc_mes0456 Adapter failed to issue ASYNCEVT_ENABLE mbox DESCRIPTION The HBA port failed to enable asynchronous mailbox
44. TY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0282 Failed to issue UNREG_VFI mailbox command DESCRIPTION Failed to issue UNREG_VFI mailbox command to the HBA DATA 1 rc 2 HBA state SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0283 Failed to allocate mbox for UNREG_FCFI cmd DESCRIPTION Failed to allocate memory for issuing UNREG_FCFI mailbox command DATA 1 HBA state SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 46 gt G EMULEX Ipfc_mes0284 Failed to issue UNREG_FCFI mailbox command DESCRIPTION Failed to issue UNREG_FCFI mailbox command to the HBA DATA 1 rc 2 HBA state SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0285 UNREG_FCEFI failed to read FCF record DESCRIPTION UNREG_FCFI failed to read FCF record from HBA DATA HBA state SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0286 Failed to allocate init_vpi mai
45. UN on NPort lt nlp_DID gt DESCRIPTION The driver issued a REPORT_LUN SCSI command to an FCP target DATA 1 nlp_failMask 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational Ipfc_mes0208 Failmask change on NPort lt nlp_DID gt on vpi lt vpi gt DESCRIPTION An event was processed that indicates the driver may not be able to communicate with the remote NPort DATA 1 nlp_failMask 2 bitmask 3 flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational lpfc_mes0209 RFT request completes ulpStatus lt ulpStatus gt CmdRsp lt CmdRsp gt DESCRIPTION A RFT request that was sent to the fabric completed DATA 1 nlp_failMask 2 bitmask 3 flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0210 Continue discovery with lt num_disc_nodes gt ADISCs to go DESCRIPTION A device discovery is in progress DATA 1 fe_adisc_cnt 2 fc_flag 3 vport gt port_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0211 DSM IN vpi lt vpi gt event lt evt gt on NPort lt nlp_DID gt in state lt cur_state gt DESCRIPTION The driver Discovery State Machine is processing an event DATA 1 nlp_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0212
46. Y Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0480 WQ_DESTROY mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be destroyed mailbox command failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0481 RQ_DESTROY mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be destroyed mailbox command failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0482 WQ_CREATE mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be created DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0483 POST_SGL mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The POST_SGL mailbox command failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technic
47. Y Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes4529 No event queue entry from the CQ DESCRIPTION No event queue entry from the CQ DATA 1 Completion Queue Id 2 Completion Queue Type SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4530 Invalid WCQE code DESCRIPTION Invalid WCQE code DATA 1 Invalid Work Queue Completion code SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4531 Fast path completion queue does not exist DESCRIPTION Fast path completion queue does not exist DATA None SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4532 No entry from fast path completion queue DESCRIPTION No entry from fast path completion queue DATA 1 Completion queue_id SEVERITY Information LOG LOG_INIT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 90 gt G EMULEX Ipfc_mes4533 FCoE Function not supported by firmware DESCRIPTION Firmware does not support FCoE DATA 1 Function mode SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4534 Init link mailbox command failed DESCRIPTION Failed to initialize the FCoE link DATA 1 mbx status SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem I
48. al Support Ipfc_mes0484 READ_REV Error SLI Level d DESCRIPTION The SLI Level should be SLI 4 and FCoE should be supported DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 66 gt G EMULEX lpfc_mes0485 Adapter firmware version lt s gt fcphHi lt x gt fcphLo lt x gt flHi lt x gt flLo lt x gt DESCRIPTION Adapter firmware version is logged DATA None SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational lpfc_mes0486 No support for fcpi mode DESCRIPTION The port must support FCP initiator mode DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0487 Feature Mismatch DESCRIPTION The port cannot support the host s requested features DATA 1 REQUEST_FEATURES Word 2 2 REQUEST_FEATURES Word 3 3 max_vpi SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational Ipfc_mes0488 READ_SPARAM command failed DESCRIPTION The port must support FCP initiator mode DATA 1 Issue status 2 mbxStatus SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical
49. are or driver problem If problems persist report these errors to Technical Support Ipfc_mes4501 READ _CONFIG failed DESCRIPTION The READ_CONFIG mailbox command failed DATA 1 mbxCmd 2 mbxStatus SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4502 Config Params XRI B lt val gt M lt val gt VPI B lt val gt M lt val gt VFI B lt val gt M lt val gt RPI B lt val gt M lt val gt FCFI B lt val gt M lt val gt DESCRIPTION Configuration parameters reported by adapter Each parameter listed has a B base value and a M max value DATA SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4503 IOCB Rsp Err ring lt no gt tag lt no gt DESCRIPTION IOCB error response DATA iocb 0 iocb 15 SEVERITY Information LOG LOG_SLI verbose ACTION None required Ipfc_mes4504 lt string gt mbox failed DESCRIPTION Failed mailbox command occurred in the function lt string gt DATA 1 shdr_status 2 shdr_add_status 3 rc SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support lpfc_mes4505 Failed to allocate XRI DESCRIPTION Unable to allocate an XRI DATA 1 next_xri 2 max_xri 3 xri_used SEVERITY Error LOG Always ACTION This error may i
50. ate 2 ulploTag 3 ulpStatus 4 ulpWord 4 SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required unless problem persists If persistent check cabling Ipfc_mes0238 NameServer Rsp DESCRIPTION The driver received a NameServer response DATA 1 Did 2 nlp_flag 3 fc_flag 4 fc_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0239 NameServer Rsp DESCRIPTION The driver received a NameServer response DATA 1 Did 2 ndlp 3 fc_flag 4 fc_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0240 NameServer Rsp Error DESCRIPTION The driver received a NameServer response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Emulex Drivers for VMware ESX 3 5 User Manual Page 40 gt G EMULEX Ipfc_mes0241 NameServer Rsp Error DESCRIPTION The driver received a NameServer response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Ipfc_mes0242 Abort outsta
51. cates 1 a possible lack of memory resources Try increasing the Ipfc num_bufs configuration parameter to allocate more buffers 2 A possible driver buffer management problem If this problem persists report the error to Technical Support Ipfc_mes0301 READ_SPARAM no buffers DESCRIPTION The driver attempted to issue a READ_SPARAM mailbox command to the HBA but there were no buffers available DATA None SEVERITY Warning LOG LOG_MBOX verbose ACTION This message indicates 1 a possible lack of memory resources Try increasing the Ipfc num_bufs configuration parameter to allocate more buffers 2 A possible driver buffer management problem If the problem persists report the error to Technical Support Ipfc_mes0302 REG_LOGIN no buffers DESCRIPTION The driver attempted to issue a REG_LOGIN mailbox command to the HBA but there were no buffers available DATA 1 did 2 rpi 3 vpi 4 flag SEVERITY Warning LOG LOG_MBOxX verbose ACTION This message indicates 1 a possible lack of memory resources Try increasing the Ipfc num_bufs configuration parameter to allocate more buffers 2 A possible driver buffer management problem If the problem persists report the error to Technical Support Ipfc_mes0304 Stray mailbox interrupt mbxCommand lt cmd gt mbxStatus lt status gt DESCRIPTION Received a mailbox completion interrupt and there are no outstanding mailbox commands DATA None SEVERITY Error
52. cccecececceeeeeceeeeeeececececeeeeceeeeeeeseeeeeeeeees 79 LIBDFC Events 1600 1699 Jeren 81 VPort Events 1800 1899 00000 nnn nn i i NENANA NA NENA NANAREN 82 Initialization Events 4500 4599 0 tt ii iiiiirereenees 86 Emulex Drivers for VMware ESX 3 5 User Manual Page iv gt G EMULEX Installation Driver Information Supported Features Protocols SCSI FCP Fibre Channel over Ethernet FCoE FC initiator mode NIC and iSCSI Supports 256 0 255 logical unit numbers LUNs Supports dynamically adding LUNs and targets Topology support Fibre Channel Arbitrated Loop FC AL point to point fabric with auto topology negotiation Support for 1 2 4 8 and 10 Gb s capable adapters with auto rate negotiation Support for up to sixteen adapter ports Remote monitoring and parameter configuration using Emulex s OneCommand Manager application and the OneCommand Manager application Command Line Interface CLI Support for Common HBA API Supports NPort ID Virtualization NPIV Technology New Features in this Release This ESX 3 5 release includes the following enhancements Supports OneConnect universal converged network adapters UCNAs for FC FCoE NIC and iSCSI including the OneConnect OCe10100 Supports the OneCommand Manager application and the OneCommand Manager application CLI The VMware Tools link on the VMware portion of the Emulex Web site Visit the link to see the available tool
53. cge word0 mcqe_tagO mcqe_tag1 mcqe trailer SEVERITY Information LOG LOG_MBOxX verbose ACTION No action needed informational Ipfc_mes0344 Restart HBA PCI function DESCRIPTION The HBA PCI function has been killed DATA 1 HBA_state 2 sli_flag SEVERITY Information LOG LOG_SLI verbose ACTION No action needed informational Ipfc_mes0345 Synchronous IOCB timeout d seconds DESCRIPTION A synchronous IOCB has not completed DATA None SEVERITY Warning LOG Always ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 54 gt G EMULEX lpfc_mes0346 Mailbox fail cmd lt opcode gt stat lt mbox_stat gt lt mcqe_stat gt DESCRIPTION A mailbox command failed DATA varWord 0 varWord 7 SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If this problem persists report these errors to Technical Support Ipfc_mes0347 Mailbox cmd x x lt x x gt lt x x gt sent data DESCRIPTION Issue a mailbox command DATA varWord 0 varWord 7 SEVERITY Information LOG LOG_MBOX ACTION No action needed informational Ipfc_mes0348 Mailbox cmd lt opcode gt cmpl DESCRIPTION A mailbox command completed DATA varWord 0 varWord 7 SEVERITY Information LOG LOG_MBOX ACTION No action needed informational Ipfc_mes0349 Mailbox sync cmd lt opcode gt lt ioctl gt cmpl DESCRIPTION A synchronous mai
54. changes to take effect Table 2 LPFC Driver Configuration Parameters Variable Default Min Max Dynamic Comments Ipfc_hba_queue_depth Oxffff 1 Oxffff Yes Maximum number of FCP commands that can queue to an Emulex adapter The value cannot exceed what the adapter supports Ipfc_initiator_login 0 0 Off 1 On Yes Enables logins to other virtual initiators Ipfc_ackO 0 0 Off 1 On No Use ACKO for class 2 Ipfc_automap 1 O Off 1 On No Automatically assign SCSI IDs to FCP targets detected Ipfc_check_cond_err 0 0 Off 1 On Yes Treat certain FCP check conditions as FCP RSP errors Emulex Drivers for VMware ESX 3 5 User Manual Page 11 Table 2 LPFC Driver Configuration Parameters Continued gt G EMULEX Variable Default Min Max Dynamic Comments Ipfc_cr_count 1 255 No This parameter determines the values for I O coalescing for cr_delay msec or cr_count outstanding commands Note This parameter only applies to SLI 3 based adapters lpfc_cr_delay 63 No This parameter determines the values for I O coalescing for cr_delay msec or cr_count outstanding commands Note This parameter only applies to SLI 3 based adapters Ipfc_delay_rsp_err 0 Off 1 On Yes Treat FCP RSP errors like no device delay lpfc_discovery_threads 30 64 No Specifies the maximum number of ELS commands that can be outstandi
55. contact VMware Technical Support for a supported driver that corrects the DMA transfer issue In addition the adapter may require a firmware upgrade The minimum firmware revisions are LP10000 series HBA 1 92a1 LP11000 series HBA 2 72a2 If you have any questions on the minimum firmware revision contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 15 ESX Server iSCSI Table 4 ESX Server iSCSI gt G EMULEX Situation Resolution If the operating system fails to install or you cannot successfully install the iSCSI or NIC drivers Verify that the operating system you are using is supported by the OneConnect Server software The Emulex iSCSI BIOS banner is not displayed during system POST Go to your motherboard BIOS configuration and ensure the Option ROM is enabled for the PCI E slot into which the OneConnect UCNA is inserted Overall failure Use the iSCSlSelect utility to clear the adapter configuration To clear the adapter configuration 1 From the Adapter menu select Clear Configuration and press lt Enter gt 2 You are prompted to clear the current configuration Press lt Y gt 3 You will be cautioned that the operation will remove any existing configuration permanently Press lt Y gt 4 After you clear the Adapter Configuration reboot the system and then reconfigure the OneConnect driver The iSCSI boot install fails Verify th
56. create vport Incorrect SLI revision DESCRIPTION The FW must report SLI 3 capable for vport creation DATA 1 sli_rev SEVERITY Warning LOG LOG_VPORT verbose ACTION Check FW revision and contact Emulex Technical Support Ipfc_mes1802 VMKernel issued unknown VPORT command rejecting DESCRIPTION The VMKernel issued an unknown vport command error command DATA 1 vport cmd SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Ipfc_mes1803 VPort unreg login to all rpis failed trying single rpi unreg DESCRIPTION The vport s unreg_login to all rpis failed defaulting to sequential unreg_login per rpi DATA 1 vport DID SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Ipfc_mes1804 VPort unreg vpi failed DESCRIPTION The VPort s unreg_login didn t complete treating as a failure and defaulting to sequential unreg_login per rpi DATA 1 vport DID SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Ipfc_mes1805 Failed to create scsi host for VPort instance d DESCRIPTION The VPort create failed because the scsi_register failed to create a SCSI host DATA 1 vport instance SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 82 gt G EMULEX Ipfc_mes1806 Failed to allocate VPort memory resources instance d DESCRIPTION The VPort create failed because the vport c
57. d entry needs to be aaa ar removed or corrected 0x31840006 The be2iscsi driver This failure occurred due to a failed memory failed to load due to allocation in the driver Check low memory memory allocation conditions failure 0x31840005 The be2iscsi driver This failure indicates the OneConnect UCNA failed to load since it has an incorrect vendor ID device ID did not find the correct subsystem vendor ID or subsystem device hardware IDs on the ID Contact Emulex technical support board 0x31840001 The be2iscsi driver This failure may be due to the firmware not failed to load because being present or running currently This failure initialization failed may also indicate a hardware issue during normal bootup 0x31640004 An internal API failed in This failure may indicate a low memory be2iscsi driver during condition initialization 0x14831000 There was an This may be due to hardware errors or due to Unrecoverable Error detected by the be2iscsi driver Following this error log entry the next 3 entries will indicate the error codes unhandled exceptions in the hardware or firmware Emulex Drivers for VMware ESX 3 5 User Manual Page 21 gt EMULEX Table 7 ESX Server iSCSI Error Log Code Entries Continued Message Id Message Recommended Resolution 0x138e0103 0x138d0101 The be2iscsi driver failed an IOCTL request since the number of scatter gather elements required for the IO
58. derrun condition to an error based on the underflow field in the SCSI command DATA 1 len 2 resid 3 underflow SEVERITY Information LOG LOG_FCP verbose ACTION None required Ipfc_mes0729 FCP cmd lt cmnd gt failed lt target gt lt lun gt DESCRIPTION The specified device failed an FCP command DATA 1 cmnd 2 scsi_id 3 lun_id 4 status 5 result 6 iotag SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question Ipfc_mes0730 FCP command failed RSP DESCRIPTION The FCP command failed with a response error DATA 1 Status2 2 Status3 3 Resld 4 SnsLen 5 RspLen 6 Info3 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question Ipfc_mes0734 FCP read check error DESCRIPTION The issued FCP command returned a read check error DATA 1 fcpDI 2 rspResld 3 fcpi_parm 4 cdb 0 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question Ipfc_mes0735 FCP read check error with check condition DESCRIPTION The issued FCP command returned a read check error and a check condition DATA 1 fcpDI 2 rspResld 3 fcpi_parm 4 cdb 0 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question Ipfc_mes0737 lt ASC ASCQ gt Check condition received DESCRIPTION The issued FCP command resulted in a check condition DATA 1 CFG_CHK_COND_ERR 2 CFG_DELAY_RSP_ERR 3
59. e OneConnect UCNA to Emulex check the message log proc vmware log and report any of these entries that may be present Note In the following table lt D gt lt DD gt or lt DDD gt in the Messages Displayed column refers to decimal values that appear in the actual error messages Table 6 ESX Server NIC Event Log Entries Severity Message Displayed Description Warning Could not get link status The firmware command to get the Link status for nmnic lt D gt returned an error Error Cannot create more than The OneConnect UCNA supports a maximum 17 interfaces of 17 interfaces This error is reported when the driver is loaded with a value more than 17 for the module parameter rings Emulex Drivers for VMware ESX 3 5 User Manual Page 17 Table 6 ESX Server NIC Event Log Entries Continued gt G EMULEX Exceeds Max Tx Frags Emulex Drivers for VMware ESX 3 5 User Manual Severity Message Displayed Description Warning add async event callback The firmware command to register for link failed Link status status changes failed Messages indicating changes may not be link status change will not appear If the link is reflected up the driver should work properly Warning Cannot support more than The driver supports up to a maximum of three 3 BE Adapters adapters More than three adapters were detected The first three adapters should work c
60. e Boot target LUN connectivity in the iSCSISelect utility Check the system BIOS for boot device priority order The firmware becomes corrupted or non responsive The firmware must be re flashed To re flash the firmware download the latest firmware from the Emulex Web site and install it using the OneCommand Manager application ESX Server NIC Table 5 ESX Server NIC Situation Resolution During boot the system hangs after the OneConnect BIOS banner is displayed The firmware may be corrupted and must be re flashed Contact Emulex Technical Support for additional assistance A lot of alloc_skb failed messages appear in the log file proc vmware log This could be due to low configured value for netPktHeapMaxSize Try increasing it to a higher value To read the current value run esxcfg advcfg j netPktHeapMaxSize A value of 0 indicates default 64MB To increase the size to for example 128 MB run esxcfg advcfg k 128 netPktHeapMaxSize netPktHeapMaxSize can also be configured through VI Client using Configuration gt Advanced Settings gt VMKernel After configuring the size reboot the system Emulex Drivers for VMware ESX 3 5 User Manual Page 16 gt G EMULEX Table 5 ESX Server NIC Continued Situation Resolution Unable to ping from one VM to another The OneConnect driver creates two vmnic interfaces one for VM each port If the
61. ed DATA None SEVERITY Error LOG Always ACTION This error indicates that this port is temporarily going offline If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 63 gt EMULEX Ipfc_mes0467 Defer error condition cleared har lt Host Att Reg gt hsr lt Host Stat Reg gt DESCRIPTION Defer error condition cleared DATA None SEVERITY Error LOG Always ACTION This error indicates that this port is no longer offline due to the defer error condition Recovery will be attempted If problems persist report these errors to Technical Support Ipfc_mes0468 Error during rpi post operation DESCRIPTION Unable to create an RPI header DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0469 Unsupported EQ count of lt d gt DESCRIPTION The event queue cannot be initialized with the specified count DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0470 EQ_CREATE mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be created DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problem
62. eeeeeeeeeeeeeeeeeeeeeeee 9 ESX Server Network Driver cccccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteetes 9 Enabling vmxnet Emulation Jumbo Frames and TSO eeeeeeeeeeeeeeees 9 Configuring the Virtual Switch to Use Jumbo Frames 10 Setting the MTU SIZO 000 cece eee tenn aiaa 10 Pinning VM and Interrupts to CPUS 0 cc ceeeeeeeeeeerereeeeeteeteteeetttttiieeeeeeed 10 Emulex LPFC Driver Configuration Parameters cccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 LPOUBDIGSMOOUING sisan nde aie le le leita adie 15 INMOQUCHON sisissicganehanssanssencgtuagapasauaganegamapanegagapdneuanesdaauaneddueuanagdaagabagdaagabagdaageaagdanguay 15 Unusual Situations and Their Resolutions cccececccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenenes 15 Genetal SIUM AUONS et ceeeccececetete teeta cetera tee A 15 ESX Sarver SCSI sbecececececedeceteeacatncntcnencnentuanete deeded elceedeccucngbenescnaneneecnnhanadueeweds 16 ESX2SeOrver NIG ecrit ed cage cacscscncnancetinenanceaeulduedaeddaedeeenenecnnneneneatnesementseteated 16 ESX Server Event Error Log MeSSages ceceee cece cece eee e eee ee tent eeeeeeeeeeeeeeeeeeeeeeees 17 Retrieving ESX Server NIC Error Log Codes ceeeeeeeeeeeeeeeeeeeeeeeeeeteeeettees 17 ESX Server NIC Event Log Entries 0 2 22 cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeeentes 17 Retrieving ESX Server iSCSI Error Log Codes cceccccceeeeeeeeeeeeeeeeeeeee
63. eeteees 20 ESX Server iSCSI Error Log Code Entries cccccecceccecceeeeeeeeeeeeeeeeeeeeeeeeeeeees 21 Additional ESX Server iSCSI Driver Messages ccccecceeeeeeeeeeeeeeeeeteteeeeees 25 EPFC Log Massages aeien neiii ea E TAE EA NOAA EEEE 26 IMMPOGUCUION sa isisistessieieieleieielereteteteecberebererersseresabeneresureseretarsreseseseserelecesanananasaces 26 MI CVETILY GOSS iessu E E ete 26 Emulex Drivers for VMware ESX 3 5 User Manual Page iii Table of Contents gt EMULEX ETRACE Logging Mechanism ccsececeeeeeeeeeeeeeeeeeeeeaeaaeeeaaaaaaaaaaeeeeeees 26 Message Group Masks cccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeess 27 Message Log Example cccccccccccccececeeeeeeeeeeeeeeeeeceaaeeaaaaaaaaaaaaaaeeeeeess 28 ELS Events 0100 0 199 sessirnir en EEEE ER 29 Link Discovery Events 0200 0299 ssssissii unu iunu uniuni u naiiai 35 Mailbox Events 0300 0399 eesssesssssssesssesesssesssnsnsnsenneesseneneeeneneneeeennannana 48 Initialization Events 0400 0499 eee eeeeeeeeeeeeeeeeeeeeeeeteeeeeeeeeenegs 56 IP Log Events 0600 0699 0 i i i innit 69 FCP Traffic History 0700 0799 eccccccecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeeeees 70 Node Table Events 0900 0999 0 0 ee eeeeeeeeeeeeeeeeeeeeeeaaeeaaeaaaaaaaaaaaaaaaeeeeeees 74 Miscellaneous Events 1200 1299 0000 i i ii tiie 77 Link Events 1300 1399 ccecccccccccece
64. es available DATA 1 mbxCommand 2 hba_state 3 sli_flag 4 flag SEVERITY Information LOG LOG_MBOxX verbose ACTION No action needed informational Ipfc_mes0309 Mailbox cmd lt cmd gt issue DESCRIPTION The driver is in the process of issuing a mailbox command DATA 1 hba_state 2 sli_flag 3 flag SEVERITY Information LOG LOG_MBOxX verbose ACTION No action needed informational Ipfc_mes0310 Mailbox command lt cmd gt timeout DESCRIPTION A mailbox command was posted to the adapter and did not complete within 30 seconds DATA 1 hba_state 2 sli_flag 3 mbox_active SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If no I O is going through the adapter reboot the system If the problem persists report the error to Technical Support Ipfc_mes0311 Mailbox command lt cmd gt cannot issue DESCRIPTION The driver is in the wrong state to issue the specified command DATA 1 hba_state 2 sli_flag 3 flag SEVERITY Information LOG LOG_MBOxX verbose ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 49 gt G EMULEX Ipfc_mes0312 Ring lt ringno gt handler portRspPut lt portRspPut gt is bigger then rsp ring lt portRspMax gt DESCRIPTION The port rsp ring put index is larger than the size of the rsp ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a softwa
65. es0217 Unknown Identifier in RSCN payload DESCRIPTION Typically the identifier in the RSCN payload specifies a domain area or a specific NPort ID If neither of these are specified a warning will be recorded DATA 1 didp gt un word DETAIL 1 Illegal identifier SEVERITY Error LOG Always ACTION Potential problem with the fabric Check with the fabric vendor Ipfc_mes0218 FDMI Request DESCRIPTION The driver is sending an FDMI request to the fabric DATA 1 fc_flag 2 hba_state 3 cmdcode SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0219 Issue FDMI request failed DESCRIPTION Cannot issue FDMI request to HBA DATA 1 cmdcode SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0220 FDMI rsp failed DESCRIPTION An error response was received to FDMI request DATA 1 be16_to_cpu fdmi_cmd SEVERITY Information LOG LOG_DISCOVERY verbose Emulex Drivers for VMware ESX 3 5 User Manual Page 37 gt G EMULEX ACTION The fabric does not support FDMI check fabric configuration Ipfc_mes0221 FAN timeout DESCRIPTION A link up event was received without the login bit set so the driver waits E_D_TOV for the fabric to send a FAN If no FAN is received a FLOGI will be sent after the timeout DATA None SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required The driver recovers from th
66. f necessary If problems persist contact Technical Support Ipfc_mes4555 Config region 23 has bad version DESCRIPTION Config region 23 has bad version DATA None SEVERITY Error LOG Always ACTION It may not be a critical problem for the driver and HBA s normal operation if configure region contains a bad version However it may result in some of the management stack functionality not working properly to manage the HBA Try to re configure the device configure region 23 if necessary If problems persist contact Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 94 gt G EMULEX Ipfc_mes4556 Config region 23 has bad signature DESCRIPTION Config region 23 has bad signature DATA None SEVERITY Error LOG Always ACTION It may not be a critical problem for the driver and HBA s normal operation if configure region contains a bad signature However it may result in some of the management stack functionality not working properly to manage the HBA Try to re configure the device configure region 23 if necessary If problems persist contact Technical Support Ipfc_mes4557 Config region 23 has bad version DESCRIPTION Config region 23 has bad version DATA None SEVERITY Error LOG Always ACTION It may not be a critical problem for the driver and HBA s normal operation if configure region contains a bad version However it may result in some of the management stack functionality not working pr
67. f problems persist report these errors to Technical Support Ipfc_mes4535 Invalid link fault code DESCRIPTION Invalid link fault code DATA 1 Link fault code SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4536 vmk_fc_attach_transport failed DESCRIPTION Failed to attach adapter instance to transport DATA None SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4537 Invalid link attention type DESCRIPTION Invalid link attention type DATA 1 Link attention type SEVERITY Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes4538 Invalid link attention link speed DESCRIPTION Invalid link attention link speed DATA 1 Link speed SEVERITY Warning LOG LOG_INIT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 91 Ipfc_mes4539 The SLI4 DCBX asynchronous event is not handled yet DESCRIPTION The SLI 4 DCBX asynchronous event is not handled yet DATA 1 Event tag SEVERITY Warning LOG LOG_INIT verbose ACTION None required lpfc_mes4540 Read FCF record failed DESCRIPTION Read FCF record failed DATA 1 Return value from mailbox cmd SEVERITY Warning LOG LOG _INIT verbose ACTION None required Ipfc_mes4541 Invalid asynchronous event code DESCRIPTION Invalid asynchronous event code
68. fc_mes0268 FCFI information DESCRIPTION This message logs detailed FCF entry information upon the completion of a register FCFI mailbox command DATA 1 idx 2 fcfi 3 rq_idO 4 rq_id1 5 rq_id2 6 rq_id3 7 tp_matchO 8 tp_mask0 9 rctl_match0 10 rctl_mask SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Information only no action needed Ipfc_mes0269 REG_VFI Data DESCRIPTION This messages logs the entire register VFI mailbox command payload DATA REG_VFI mailbox payload word0 word15 SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Information only no action needed Ipfc_mes0270 REG_VFI mbxStatus error DESCRIPTION Register VFI mailbox failed DATA 1 mbxStatus 2 HBA state 3 RPI bitmap SEVERITY Error LOG Always ACTION Check the fabric configuration and reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0271 Issue Register VFI failed DESCRIPTION Issue register VFI mailbox failed DATA 1 vpi 2 err SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 44 gt G EMULEX Ipfc_mes0272 Failed to allocate mbox for READ_FCF cmd DESCRIPTION Failed to allocate memory for issuing READ_FCF mailbox command DATA None SEVERITY Error LOG Always ACTI
69. g SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required If problem persists contact Technical Support Ipfc_mes4522 Unknown FCoE event received from network DESCRIPTION The network received an unknown FCoE event DATA 1 fcf_event_type 2 acqe_event_tag SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required Ipfc_mes4523 Invalid CT command DESCRIPTION Invalid CT command DATA 1 ct 2 command SEVERITY Warning LOG LOG _INIT verbose ACTION None required Ipfc_mes4524 Failed to allocate CQ_EVENT entry DESCRIPTION Failed to allocate CQ_EVENT entry DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required If problem persists contact Technical Support Ipfc_mes4525 Invalid work queue CQE subtype DESCRIPTION Invalid work queue CQE subtype DATA 1 CQE subtype SEVERITY Warning LOG LOG_INIT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 89 gt G EMULEX Ipfc_mes4526 Not a valid WCQE code DESCRIPTION Not a valid WCQE code DATA 1 WCQE code SEVERITY Warning LOG LOG _INIT verbose ACTION None required Ipfc_mes4527 Receive Frame Truncated DESCRIPTION Receive Frame is truncated DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes4528 Invalid completion queue type DESCRIPTION Invalid completion queue type DATA 1 Completion Queue Type SEVERIT
70. ges are disabled Configuration error c error e and panic p messages can not be disabled Table 8 Severity Code Table Code Severity i Information w Warning c Configuration Error e Error p Panic ETRACE Logging Mechanism The U4 Async LPFC driver includes a new logging mechanism called ETRACE The ETRACE mechanisms are embedded in the code to capture information during any unexpected failures or events The ETRACE mechanism displays information in the following format lt func_name gt lt hba_boardno gt ETRACE_ lt no Line gt where e func_name the function name e hba_boardno the HBA model number e no Line the line number in the code where this ETRACE occurs Emulex may use ETRACEs to troubleshoot customer issues Emulex Drivers for VMware ESX 3 5 User Manual Page 26 Message Group Masks gt G EMULEX Table 9 defines the log message groups and the associated number ranges The preamble string shown in this table is displayed as part of the log message e The lower case x of the preamble string defines the severity of the log message and represents one of five lower case letters defined in the severity codes table Table 9 Message Log Table LOG Message Preamble TYF Verbose Mask String From To Verbose Verbose Description ae Bit Definition LOG_ELS ELx 0100 0199 0x1 ELS events LOG_DISCOVE
71. ho link vmnicO to vSwitcho The only difference being that in vNIC mode each of the four vNICs tied to a physical port share the port s 10GbE bandwidth Configuring VLANs The OneConnect NIC driver is programmed to perform VLAN filtering in the hardware To configure VLANs on a OneConnect NIC driver interface create the vSwitch with the required VLAN ID and this interface as an adapter to this vSwitch Native VLAN configuration in the guest operating system for example using vconfig in the Linux guest operating system is not supported Configuring Network Heap Size in ESX Server By default the ESX Server network stack allocates 64MB of buffers to handle network data If the network load requires more than 64MB of memory to hold the in transit network data the OneConnect NIC driver cannot allocate memory for posting receive buffers When this happens the NIC driver logs messages in the file proc vmware log indicating that the alloc_skb call failed This impacts the network performance considerably e To increase the network heap size to a larger value for example 128MB run esxcfg advcfg k 128 netPktHeapMaxSize esxcfg advcfg j netPktHeapMaxSize netPktHeapMaxSize 128 The new value takes effect after a reboot To read the current size of the network heap run esxcfg advcfg j netPktHeapMaxSize netPktHeapMaxSize 0 If the default value of the 64MB is in effect this command shows the size as 0 If any othe
72. iately following this entry will indicate the TMF function code that was rejected The operating system version is not supported 0x11940008 The be2iscsi driver received a Task Management Function Abort request for an I O request that is not present with the driver Emulex Drivers for VMware ESX 3 5 User Manual This may indicate a slow connection to the target Check network connectivity to the target for any errors Page 23 gt G EMULEX Table 7 ESX Server iSCSI Error Log Code Entries Continued Message Id Message Recommended Resolution 0x11840002 The be2iscsi driver encountered a mismatched version of the firmware running on the board This error may be followed by more error codes 0x31840001 or 0x31880001 indicating that the beiscsi driver failed to load This failure indicates that the driver version that is running on the system does not match the firmware version flashed on the board To correct this issue run the installer from the desired firmware version 0x11840001 The be2iscsi driver detected a failure in the hardware during initialization This error may be followed by more error codes 0x31840001 or 0x31880001 indicating that the beiscsi driver failed to load This failure indicates that the hardware has not been initialized or is malfunctioning This may also indicate that the firmware is not running correctly 0x11800005 Both Port 0 and
73. ied buffer in its mapping table Therefore the driver cannot find the virtual address needed to access the data DATA 1 first 2 q_first 3 q_last 4 q_cnt SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0411 fcp_bind_method is 4 with Persistent binding ignoring fcp_bind_method DESCRIPTION The configuration parameter for fcp_bind_method conflicts with Persistent binding parameter DATA 1 a_current 2 fcp_mapping SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file Ipfc_mes0412 Scan down is out of range ignoring scan down DESCRIPTION The configuration parameter for scan down is out of range DATA 1 clp CFG_SCAN_DOWN a_current 2 fcp_mapping SEVERITY Error LOG Always ACTION Make necessary changes to the Ipfc configuration file Ipfc_mes0413 Configuration parameter out of range resetting to default value DESCRIPTION User is attempting to set a configuration parameter to a value not supported by the driver Resetting the configuration parameter to the default value DATA 1 a_string 2 a_low 3 a_hi 4 a_default SEVERITY Error config LOG Always ACTION Make necessary changes to the Ipfc configuration file Emulex Drivers for VMware ESX 3 5 User Manual Page 57 gt G EMULEX Ipfc_mes0430 WWPN binding entry lt num gt
74. inkdown_tmo 30 255 Yes seconds How long the driver waits before deciding that the FC link is down Ipfc_link_speed O auto select 1 1 Gb s 2 2 Gb s 4 4 Gb s 8 8 Gb s No Sets link speed Note This parameter is only applicable to SLI 3 based adapters lpfc_log_verbose 0x0 0x0 Oxffff Yes bit mask Extra activity logging lpfc_lun_queue_depth 30 128 Yes Default max commands sent to a single logical unit disk Ipfc_lun_skip 0 Off 1 On No Allows SCSI layers to detect all LUNs if there are LUN holes on a device lpfc_max_lun 256 256 Yes Specifies the maximum number of LUNs per target A value of 20 means LUNs from 0 to 19 are valid lpfc_max_target 256 256 No This configuration parameter limits how many targets the driver will support lpfc_max_vpi Oxffff Oxffff No NPIV Maximum number of vpis available per physical port lpfc_nodev_holdio 0 Off 1 On Yes If the device disappears hold I O until it comes back lpfc_no_device_delay lpfc_nodev_tmo 30 30 255 Emulex Drivers for VMware ESX 3 5 User Manual Yes Yes Delay to fail back an I O in seconds Seconds to hold I O err if device disappears Page 13 Table 2 LPFC Driver Configuration Parameters Continued gt G EMULEX Variab
75. intended FCP WQ ID DATA 1 Event Queue ld 2 FCP WQ Id SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4517 Invalid Completion event code DESCRIPTION An invalid fast path completion event was received DATA 1 majorcode 2 minorcode SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4518 Fast path EventQ has a different Queue Id DESCRIPTION Fast path EventQ has a different Queue ID DATA 1 Event Queue ld 2 FCP Q Id SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 88 gt G EMULEX Ipfc_mes4519 New FCF Index was discovered DESCRIPTION A new FCF index was discovered DATA 1 fcf _index 2 event_tag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION None required lpfc_mes4520 FCF Table full DESCRIPTION The FCF table is full DATA 1 count 2 event_tag SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required If problem persists contact Technical Support Ipfc_mes4521 FCF disconnected from network DESCRIPTION FCF disconnected from the network DATA 1 fcf_index 2 event_ta
76. ion of the VMware Web site Configuring the Virtual Switch to Use Jumbo Frames To use jumbo frames you must increase the Maximum Transmission Unit MTU in the vSwitch and the guest operating system For the best performance and resource utilization set the MTU in the virtual switch and guest operating system to the maximum 8179 bytes supported by the OneConnect driver Setting the MTU Size In a vSwitch To change the MTU to 8179 in the COS run the following command for each switch in the console operating system esxcfg vswitch vSwitch lt N gt m 8179 where lt N gt is the number of the switch In a Linux Guest Operating System To set the MTU of the OneConnect driver interface in each Linux guest operating system to 8179 run the following command ifconfig eth lt N gt mtu 8179 where lt N gt is the number of the Ethernet interface on which you are working In a Windows Guest Operating System To set the MTU in each Windows guest operating system 1 From the Start menu select Control Panel gt System Select the Hardware tab and open Device Manager Expand the Network Adapters heading Right click the NIC and select Properties Select the Advanced tab and set the MTU value or oe oN Pinning VM and Interrupts to CPUs The OneConnect NIC interface driver supports MSI X interrupts The driver requests separate MSI X IRQ vectors for each of the interfaces Pinning VMs and the IRQ vector to a CPU core provides the
77. is condition by issuing a FLOGI to the fabric Ipfc_mes0222 Initial FLOGI timeout DESCRIPTION The driver sent the initial FLOGI to fabric and never got a response back DATA None SEVERITY Error LOG Always ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Ipfc_mes0223 Timeout while waiting for NameServer login DESCRIPTION Our login request to the NameServer was not acknowledged within RATOV DATA None SEVERITY Error LOG Always ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Ipfc_mes0224 NameServer Query timeout DESCRIPTION Node authentication timeout node Discovery timeout A NameServer Query to the fabric or discovery of reported remote NPorts is not acknowledged within R_A_TOV DATA 1 fe_ns_retry 2 fe_max_ns_retry SEVERITY Error LOG Always ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Ipfc_mes0225 Device Discovery completes on vpi lt vpi gt DESCRIPTION This indicates successful completion of device re discovery after a link up DATA None SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0226 Device discovery completion error DESCRIPTION This indicates that an uncorrectable error was encountered during device re discovery after a link up Fibre Channel devices wil
78. k speed 4 number of entries in the loop init LILP ALPA map An ALPA map message is also recorded if LINK_EVENT verbose mode is set Each ALPA map message contains 16 ALPAs 5 mm 6 ft SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network Ipfc_mes1304 Link Up Event ALPA map DESCRIPTION A link up event was received DATA 1 wd1 2 wd2 3 wd3 4 wd4 SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network Emulex Drivers for VMware ESX 3 5 User Manual Page 79 gt G EMULEX Ipfc_mes1305 Link Down Event lt eventTag gt received DESCRIPTION A link down event was received DATA 1 fc_eventTag 2 hba_state 3 fc_flag SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network Ipfc_mes1306 Link Down timeout DESCRIPTION The link was down for greater than the configuration parameter lpfc_linkdown_tmo in seconds All I O associated with the devices on this link will fail DATA 1 hba_state 2 fc_flag 3 fe_ns_retry SEVERITY Warning LOG LOG_LINK_EVENT LOG_DISCOVERY verbose ACTION Check the HBA cable connection to the Fibre Channel network Ipfc_mes1307 READ_LA mbox error lt mbxStatus gt state lt hba_state gt DESCRIPTION The driver cann
79. l not be accessible if this message is displayed DATA None SEVERITY Error LOG Always ACTION Reboot the system If the problem persists report the error to Technical Support Run with verbose mode on for more details Emulex Drivers for VMware ESX 3 5 User Manual Page 38 gt G EMULEX Ipfc_mes0227 Node Authentication timeout DESCRIPTION The driver has lost track of what NPorts are being authenticated DATA None SEVERITY Error LOG Always ACTION None required The driver should recover from this event Ipfc_mes0228 CLEAR LA timeout DESCRIPTION The driver issued a CLEAR_LA that never completed DATA None SEVERITY Error LOG Always ACTION None required The driver should recover from this event Ipfc_mes0229 Assign scsi ID lt sid gt to NPort lt nlp_DID gt DESCRIPTION The driver assigned a SCSI ID to a discovered mapped FCP target DATA 1 nlp_bind_type 2 nlp_flag 3 nlp_state 4 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational Ipfc_mes0230 Cannot assign scsi ID on NPort lt nlp_DID gt DESCRIPTION The driver cannot assign a SCSI ID to a discovered mapped FCP target DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION Check persistent binding information Ipfc_mes0231 RSCN timeout DESCRIPTION The driver has lost track of what NPorts have RSCNs pending DATA
80. lbox DESCRIPTION Failed to allocate memory for issuing init_vpi mailbox command DATA 1 vpi SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0287 Failed to issue init_vpi mailbox DESCRIPTION Failed to issue init_vpi mailbox command DATA 1 vpi SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Emulex Technical Support lpfc_mes0288 No NPIV Fabric support DESCRIPTION The switch fabric does not support NPIV DATA 1 vpi SEVERITY Error LOG Always ACTION Check the fabric capability and configuration for NPIV support Ipfc_mes0289 Adapter message DESCRIPTION When the response IOCB carrys an unknown IOCB type and the upper layer command is an adapter message it logs the adapter message returned from the adapter DATA Message returned from the adapter SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed the driver will recover from this and continue with normal operation Emulex Drivers for VMware ESX 3 5 User Manual Page 47 gt G EMULEX Mailbox Events 0300 0399 Ipfc_mes0300 READ_LA no buffers DESCRIPTION The driver attempted to issue a READ_LA mailbox command to the HBA but there were no buffers available DATA None SEVERITY Warning LOG LOG_MBOX verbose ACTION This message indi
81. lbox command completed DATA varWord 0 varWord 12 cqe 0 cqe 3 SEVERITY Information LOG LOG_MBOX ACTION No action needed informational Ipfc_mes0350 REG_FCFI mbx returned an error DESCRIPTION REG_FCFI mbx returned an error DATA 1 mbxStatus 2 vport_state SEVERITY Error LOG LOG_MBOX ACTION No action needed Ipfc_mes0351 Mailbox command timed out DESCRIPTION Indicates mailbox command timeout for SLI 4 HBA and no action was taken by the driver DATA 1 mbxCmd SEVERITY Error LOG Always ACTION If the system stopped working after this message was logged reboot the system Otherwise no action is needed If the problem persists contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 55 gt G EMULEX Initialization Events 0400 0499 lpfc_mes0400 Ipfc_740 load failed lt reason gt DESCRIPTION An Ipfc_740 driver instance failed to load DATA lt function gt lt reason gt lt value gt SEVERITY Information LOG LOG_INIT ACTION No action needed informational Ipfc_mes0401 Detected Emulex PCI X HBA DESCRIPTION An Emulex PCI X HBA was detected during initialization DATA 1 jedec_id 2 pci device id Severity Information Log LOG_INIT verbose Action No action needed informational Ipfc_mes0402 Max DMA Length mailbox command failed DESCRIPTION The driver could not set the limit the max DMA length DATA 1 mbxCommand 2 mbxStatus
82. le Default Min Max Dynamic Comments Ipfc_ns_threads 2 1 32 Yes NPIV Number of concurrent NameServer requests allowed to be outstanding Ipfc_pci_max_read 0 0 driver default No The maximum number of 512 512 bytes bytes transferred per pci 1024 1024 bytes DMA read The default 2048 2048 bytes value 0 means the driver 4096 4096 bytes will automatically determine the correct value Update1 only Ipfc_peer_vport_login 0 0 1 Yes NPIV Allows peer vports to log into each other Ipfc_scan_down 1 0 Off 1 On Yes Select method for scanning ALPA to assign a SCSI ID Ipfc_scsi_req_tmo 30 0 255 Yes Time out value in seconds for SCSI passthrough requests Ipfc_tgt_queue_depth Oxffff 1 Oxffff Yes Default max commands sent to a single target Value not to exceed what the adapter supports minus ten see Ipfc_hba_queue_depth For example if the adapter supports 512 the target will default to 502 Ipfc_topology 0 0x0 loop No FC link topology defaults to then P2P loop if it fails attempts 0x2 P2P only point to point mode 0x4 loop only Note This parameter only 0x6 P2P applies to SLI 3 then loop based adapters Ipfc_use_adisc 0 0 Off 1 On Yes Send ADISC instead of PLOGI for device discovery or RSCN Emulex Drivers for VMware ESX 3 5 User Manual Page 14 Troubleshooting Introduction gt G EMULEX There are several circumstances in which your system may operate in an unexpected manner The Troubleshooting section
83. list DESCRIPTION An event posted to the task list wasn t recognized DATA 1 evt 2 arg1 3 arg2 SEVERITY Error LOG Always ACTION If this condition persists contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 42 gt G EMULEX Ipfc_mes0256 Start nodev timer DESCRIPTION A target disappeared from the Fibre Channel network If the target does not return within nodev tmo timeout all I O to the target will fail DATA 1 nlp_DID 2 nlp_flag 3 nlp_state 4 nlp SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0260 Stop Nodev timeout on NPort lt nlp_DID gt DESCRIPTION The FCP target was rediscovered and I O can be resumed DATA 1 nlp_DID 2 nlp_flag 3 nlp_state 4 nlp SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check Fabric configuration The driver recovers from this and continues Ipfc_mes0261 FAN received DESCRIPTION A FAN was received from the fabric DATA NONE SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0O262 NameServer Rsp Error DESCRIPTION The driver received a nameserver response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device di
84. manage systems remotely using TCP IP based management For instructions see Opening the ESX Server Firewall on page 3 LPFC Driver Configuration Methods Using Native ESX Tools There are two methods for configuring the Fibre Channel LPFC driver parameters using the native ESX tools e Permanent global configuration e Permanent per adapter configuration Note In addition to the permanent methods the OneCommand Manager application also supports temporary methods both global and per adapter for configuring driver parameters Emulex recommends using the OneCommand Manager application to set the configuration parameters Refer to the OneCommand Manager Application User Manual for more information Note Any settings configured using the native ESX tools will not take effect until the server is rebooted However any changes to dynamic parameters made using the OneCommand Manager application CLI immediately take effect See Emulex LPFC Driver Configuration Parameters on page 11 for more information on driver parameters Permanent Configuration Methods Permanent configuration requires that the new values be saved in the ESX environment These changes are considered permanent because they persist across system reboots Emulex Drivers for VMware ESX 3 5 User Manual Page 6 gt G EMULEX To make changes that impact all adapters in the system global changes follow these steps See LPFC Driver Configuration Para
85. mes0333 UNREG_VPI failed DESCRIPTION Unreg_vpi mailbox failed DATA 1 status SEVERITY Error LOG Always ACTION This error could indicate a driver or firmware problem If problems persist report these error to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 53 gt G EMULEX Ipfc_mes0339 Port temp ld Celsius critical Corrective action required DESCRIPTION The HBA port is at a critical temperature and must be cooled down DATA 1 temperature SEVERITY Error LOG Always ACTION This error could indicate a hardware or system problem Stop all traffic and check system fans If problems persist report these errors to Technical Support Ipfc_mes0340 Port temp ld Celsius has returned to normal DESCRIPTION The HBA port temperature has decreased to a normal value DATA 1 temperature SEVERITY Information LOG LOG_TEMP verbose ACTION No action needed Informational Ipfc_mes0341 Restart HBA DESCRIPTION The HBA has been restarted DATA 1 HBA_state 2 sli_flag SEVERITY Information LOG LOG_SLI verbose ACTION No action needed Ipfc_mes0342 Restart HBA DESCRIPTION The HBA has been killed DATA 1 HBA_state 2 sli_flag SEVERITY Information LOG LOG_SLI verbose ACTION No action needed Informational Ipfc_mes0343 Mailbox cmd lt x x gt Status lt x x gt Data lt x x gt DESCRIPTION Results of read rcoe parameter mbox command DATA MBOX 0 16 50 m
86. meters on page 11 for parameter names and values Parameter values are hexadecimal and decimal 1 From the Console Operating System COS terminal window type esxcfg module s param value param2 value lt driver_name gt The lt driver_name gt is obtained from the vmkload_mod 1 call Look for the Ipfc prefix 2 Rebuild the ESX bootstrap settings Type esxcfg boot b 3 Reboot the server Type reboot Example of Permanent Global Configuration The following example sets lun_queue_depth to 20 default is 30 for all Emulex adapters in your system 1 Locate the parameter in Table 2 on page 11 2 Set the permanent value Type esxcfg module s lpfc_ lun queue depth 20 lt driver name gt 3 Rebuild the ESX bootstrap settings Type esxcfg boot b 4 Reboot the server Type reboot The new setting is used when the driver reloads To verify the setting type esxcfg module g lpfc_740 Example of Permanent Per Adapter Configuration The following example sets lun_queue_depth to 20 default is 30 for adapter 1 1 Set the adapter specific value Type esxcfg module s lpfcl_lun_queue_depth 20 lt driver_ name gt 2 Rebuild the ESX bootstrap settings Type esxcfg boot b 3 Reboot the server Type reboot The new setting is used when the driver reloads To verify the setting type esxcfg module g lpfc_740 The following example sets lun_queue_depth to 20 default is 30 for adapter 1 and lu
87. n band management FC based management is not supported on VMware ESX 3 5 servers Use out of band management TCP IP based management to remotely manage adapters on ESX 3 5 servers Opening the ESX Server Firewall For the VMware ESX 3 5 Server the firewall on the ESX Server must be opened to manage systems remotely using TCP IP based management To enable TCP port 23333 run the following commands esxcfg firewall openPort 23333 tcp in OneCommand esxcfg firewall openPort 23333 tcp out OneCommand To verify that the correct port is open run the following command esxcfg firewall q The TCP port number can be changed If it is not changed the default is 23333 Refer to the VMware Server Configuration Guide for more details on how to configure the ESX firewall Emulex Drivers for VMware ESX 3 5 User Manual Page 3 56 EMULEX Uninstalling the Drivers To uninstall a specific driver binary RPM file e For the FC FCoE driver type rpm e VMware esx drivers scsi lpfc_elx_v740 350 lt driver version gt e For the NIC driver type rpm e VMware esx drivers be2net 2 101 lt driver version gt e For the iSCSI driver type rpm e VMware esx drivers be2iscsi 2 101 lt driver version gt Installing the OneCommand Manager Application CLI New VMware Systems To install the OneCommand Manager application CLI on a new system install the specific rpm file for your VMware driver version Prerequisites e The LPFC driver
88. n needed informational Ipfc_mes0O111 Dropping received ELS cmd DESCRIPTION The driver decided to drop an ELS response ring entry DATA 1 ulpStatus 2 ulpWord 4 SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 30 gt G EMULEX lIpfc__mes0112 ELS command lt elsCmd gt on vpi lt vpi gt received from NPORT lt did gt DESCRIPTION Received the specific ELS command from a remote NPort DATA 1 fc_ffstate SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0113 An FLOGI ELS command lt elsCmd gt was received from DID lt did gt in Loop Mode DESCRIPTION While in Loop Mode an unknown or unsupported ELS command was received DATA None SEVERITY Error LOG Always ACTION Check device DID Ipfc_mes0114 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPort and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi 5 vpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0115 Unknown ELS command lt elsCmd gt received from NPort lt did gt DESCRIPTION Received an unsupported ELS command from a remote NPort DATA None SEVERITY Error LOG Always ACTION
89. n_queue_depth to 10 default is 30 for adapter 2 1 Set the adapter specific value Type esxcfg module s lpfcl_lun_queue_depth 20 lpfc2 lun queue depth 10 lt driver name gt Note Type the command all on one line without a carriage return Emulex Drivers for VMware ESX 3 5 User Manual Page 7 gt G EMULEX 2 Rebuild the ESX bootstrap settings Type esxcfg boot b 3 Reboot the server Type reboot The new settings are used when the driver reloads To verify the settings type esxcfg module g lpfc_740 Dynamically Add LUNs and Targets For instructions on dynamically adding LUNs and targets refer to the Using Rescan section in VMware s vi3_esx_san_cfg pdf Creating a Fibre Channel Remote Boot Disk For instructions on creating a Fibre Channel remote boot disk refer to VMware s vi3_esx_san_cfg pdf Chapter 6 Using Boot from SAN with ESX Server Systems Virtualization Features For instructions on how to install the VMware Tools in guest operating systems refer to the Support section of the VMware Web site Configuring Multiple NIC Interfaces with OneConnect UCNAs Enabling the NetQueue Feature To use the multiple interface feature in ESX Server 3 5 you must enable the NetQueue feature in ESX Server which is disabled by default e To check if NetQueue is enabled run the following command from the ESX Server console ESX esxcfg advcfg j netNetqueueEnabled If it prints netNetque
90. nd did not complete within ULP timeout seconds DATA 1 did 2 sid 3 command 4 iotag SEVERITY Error LOG Always ACTION If I O is not going through the adapter reboot the system If problems persist report these errors to Technical Support Ipfc_mes0755 Invalid_tag id sent by the mgmt layer or tag_id not in use DESCRIPTION An invalid_tag id was sent by the management layer or the tag_id is not in use DATA 1 tag_id 2 in_use field SEVERITY Error LOG Always ACTION This error could indicate a driver and or management stack problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 72 gt G EMULEX lIpfc__mes0756 Null NDLP for oxid DESCRIPTION Null NDLP for oxid DATA 1 oxid 2 sid 3 tag SEVERITY Error LOG Always ACTION This error could indicate a driver and or management stack problem If problems persist report these errors to Technical Support Ipfc_mes0757 IOCB Data DESCRIPTION Log IOCB data fields DATA 1 vip 2 context2 3 context3 4 remotelD SEVERITY Information LOG LOG_FCP verbose ACTION None required Ipfc_mes0758 Failed to allocate iocb DESCRIPTION Failed to allocate IOCB for passing unsolicited receive sequence to upper layer protocol DATA 1 els ring number 2 fh_r_ctil 3 fh_type SEVERITY Error LOG Always ACTION None required just one sequence got dropped However if the pr
91. ndicate a software driver problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 86 gt G EMULEX lpfc_mes4506 Work Queue Full DESCRIPTION Unable to add element to work queue because the adapter has not processed the oldest element DATA 1 host_index 2 entry_count 3 hba_index SEVERITY Warning LOG LOG_SLI verbose ACTION None required Ipfc_mes4508 FCP complete w o iocb DESCRIPTION Cannot find the FCP command IOCB using the iotag lookup DATA 1 iotag SEVERITY Error LOG Always ACTION This error may indicate a hardware firmware or driver problem If problems persist report these errors to Technical Support Ipfc_mes4509 ELS complete w o iocb DESCRIPTION Cannot find the ELS command IOCB using the iotag lookup DATA 1 iotag SEVERITY Error LOG Always ACTION This error may indicate a hardware firmware or driver problem If problems persist report these errors to Technical Support Ipfc_mes4510 Unrecoverable Adapter Error DESCRIPTION Error Attention reported by the adapter DATA 1 uerr_lo 2 uerr_hi 3 ue_mask_lo_reg 4 ue_mask_hi_reg SEVERITY Error LOG Always ACTION This error may indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes4511 Cannot issue mailbox cmd lt opcode gt DESCRIPTION Mailbox command cannot be issued DATA 1 vpi 2
92. nding I O to the Fabric DESCRIPTION All outstanding I Os to the fabric are cleaned up DATA 1 Fabric_DID SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0243 Issue FDMI request failed DESCRIPTION Cannot issue an FDMI request to HBA DATA 1 cmdcode SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0244 Issue FDMI request failed DESCRIPTION Cannot issue an FDMI request to the HBA DATA 1 cmdcode SEVERITY Information LOG LOG_Discovery verbose ACTION No action needed informational Ipfc_mes0245 ALPA based bind method used on an HBA which is in a nonloop topology DESCRIPTION ALPA based bind method used on an HBA which is not in a loop topology DATA 1 topology SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION Change the bind method configuration parameter of the HBA to 1 WWNN 2 WWPN or 3 DID Ipfc_mes0246 RegLogin failed DESCRIPTION The firmware returned a failure for the specified RegLogin DATA Did mbxStatus hbaState vpi SEVERITY Error LOG Always ACTION This message indicates that the firmware could not do RegLogin for the specified DID There may be a limitation on how many nodes an HBA can see Emulex Drivers for VMware ESX 3 5 User Manual Page 41 gt G EMULEX Ipfc_mes0247 Start Discovery Timer state lt hba_state gt DESCRIPTION Start the device discovery RSCN
93. needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 29 gt G EMULEX lpfc__mes0106 ELS cmd tag lt ulploTag gt completes DESCRIPTION The specific ELS command was completed by the firmware DATA 1 ulpStatus 2 ulpWord 4 SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0107 Retry ELS command lt elsCmd gt to remote NPort lt did gt DESCRIPTION The driver is retrying the specific ELS command DATA 1 retry 2 delay SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0108 No retry ELS command lt elsCmd gt to remote NPort lt did gt DESCRIPTION The driver decided not to retry the specific ELS command that failed DATA 1 retry 2 nlp_flag SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0109 ACC to LOGO completes to NPort lt nlp_DID gt DESCRIPTION The driver received a LOGO from a remote NPort and successfully issued an ACC response DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0110 ELS response tag lt ulploTag gt completes DESCRIPTION The specific ELS response was completed by the firmware DATA 1 ulpStatus 2 ulpWord 4 3 nlp_DID 4 nlp_flag 5 nlp_state 6 nle nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No actio
94. ng for a discovery Ipfc_daqfull_ throttle _up_inc 128 Yes Amount to increment LUN queue depth each time lpfc_dafull_throttle_up_time 30 Yes Time interval in seconds to increment LUN queue depth lpfc_extra_io_tmo 255 Yes Extra FCP cmd timeout when connected to a fabric in seconds Ipfc_fcp_bind_DID inactive N A N A No Bind specific SCSI IDs to targets based on Fibre Channel FC Port ID lpfc_fcp_bind_method No Specifies the bind method WWWN WWPN DID ALPA map to be used lpfc_fcp_bind_WWNN inactive N A N A No Bind specific SCSI IDs to targets based on FC WWNN lpfc_fcp_bind_WWPN inactive N A N A No Bind specific SCSI IDs to targets based on FC WWPN lpfc_fcp_class Yes FC class for FCP data transmission Emulex Drivers for VMware ESX 3 5 User Manual Page 12 Table 2 LPFC Driver Configuration Parameters Continued gt G EMULEX Variable Default Min Max Dynamic Comments Ipfc_fcp_imax 10000 636 651042 Yes Set the maximum number of fast path FCP interrupts per second Note This parameter only applies to Emulex UCNAs lpfc_fdmi_on No False 0 if disabled 1 or 2 if enabled depending on type of support needed lpfc_iocb_wdog_tmo 40 55 No Timeout value for pending FC I O in the driver lpfc_l
95. nt to the fabric failed DATA 1 ulpStatus 2 ulpWord 4 SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0101 FLOGI completes successfully DESCRIPTION An ELS FLOGI command that was sent to the fabric succeeded DATA 1 ulpWord 4 2 e_d_tov 3 r_a_tov 4 edtovResolution SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0102 PLOGI completes to NPort lt nlp_DID gt on vpi lt vpi gt DESCRIPTION The HBA performed a PLOGI into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 disc 4 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0O103 PRLI completes to NPort lt nip_DID gt DESCRIPTION The HBA performed a PRLI into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0104 ADISC completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed an ADISC into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 disc 4 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0105 LOGO completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed a LOGO to a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action
96. o init mbxCmd lt cmd gt CFG_RING mbxStatus lt status gt ring lt num gt DESCRIPTION Adapter initialization failed when issuing a CFG_RING mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0447 Adapter failed init mbxCmd lt cmd gt CONFIG_LINK mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_LINK mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0448 Adapter failed to init mbxCmd lt cmd gt READ_SPARM mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing a READ_SPARM mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0451 Enable interrupt handler failed DESCRIPTION The driver attempted to register the HBA interrupt service routine with the host operating system but failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or driver problem If the problem persists report the error to Technical Support Ipfc_mes0452 Adapter failed to init mbxCmd lt cmd gt CONFIG_HBQ mbx
97. oblem persists it might have impact on inband management Reboot the system if necessary Ipfc_mes0759 Outstanding SCSI command in the scheduler DESCRIPTION Log HBA information when there are outstanding SCSI commands in the scheduler DATA 1 hba_cr 2 hba_max 3 hba_stsx 4 trgt_Ic 5 tgt_cr 6 tgt_max 7 t_sts 8 lun_cr 9 lun_max 10 lun_st SEVERITY Information LOG LOG_FCP verbose ACTION None required Ipfc_mes0760 SCSI buffer to be freed has null pointer DESCRIPTION The SCSI buffer to be freed has a null pointer so a potential issue exists DATA None SEVERITY Error LOG Always ACTION None required if it only happened once or so However if the problem persists reset the HBA or reboot the system Ipfc_mes0761 SCSI buffer count out of range DESCRIPTION The SCSI buffer count in the SCSI command is out of range DATA 1 count SEVERITY Error LOG Always ACTION A SCSI command returned with a busy state No action is required if it only happened once or so However if the problem persists reboot the system Emulex Drivers for VMware ESX 3 5 User Manual Page 73 gt G EMULEX Node Table Events 0900 0999 Ipfc_mes0900 Cleanup node for NPort lt nlp_DID gt on vpi lt vpi gt DESCRIPTION The driver node table entry for a remote NPort was removed DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi 4 status SEVERITY Information LOG LOG_NODE verbose ACTION None required
98. operly to manage the HBA Try to re configure the device configure region 23 if necessary If problems persist contact Technical Support Ipfc_mes4558 Init VPI mailbox failed DESCRIPTION Initialize VPI mailbox command completion returned failure DATA 1 mbox cmd status SEVERITY Error LOG Always ACTION The specific vport will be put into an error state May need to reset HBA or reboot system to recover If problems persist contact Technical Support Ipfc_mes4559 No NPIV Fabric support DESCRIPTION The switch fabric does not support NPIV DATA None SEVERITY Error LOG Always ACTION Check the fabric capability and configuration for NPIV support Ipfc_mes4560 UNREG_FCFI mbox allocation failed DESCRIPTION Failed to allocate memory for issuing UNREG_FCFI mailbox command DATA None SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Technical Support Ipfc_mes4561 UNREG_FCFI issue mbox failed DESCRIPTION Failed to issue UNREG_FCFI mailbox command to the HBA DATA None SEVERITY Error LOG Always ACTION Driver failure reboot the system if necessary If this condition persists contact Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 95 gt G EMULEX Ipfc_mes4562 Received unknown vport command DESCRIPTION The driver received an unknown vport command DATA 1 vport cmd 2 arg SEVERITY Warning
99. ormally Warning Wrong PD ID lt DD gt An ioctl to configure QoS was issued with a wrong PD ID value The request is ignored and the QoS setting is not changed Error betx_ether_ frame The driver received a transmit request with more than 30 fragments The request failed since the OneConnect UCNA does not support more than 30 SG elements in a TX request This should not normally happen in ESX Server 3 5 Page 18 Table 6 ESX Server NIC Event Log Entries Continued gt G EMULEX settings Severity Message Displayed Description Error BniInit failed Error Initialization of the host data structures to lt DDD gt access the network function of the OneConnect UCNA reported an error Error Interface initialization Allocation of resources for the network failed interface failed Warning MSIX Request IRQ failed Request for MSI X interrupt registration for for pd id lt DD gt Errno the interface vmnic0 lt DD gt failed The lt DDD gt OneConnect NIC driver interface should still work with INT X interrupts Error INTx Request IRQ failed Request for INT X interrupt registration failed Errno lt DDD gt This error is caused by system resource limitations The OneConnect NIC driver interface is unusable Warning Failed to register char Could not create the char device used for device certain management functions The driver must still work Error pci_enable_de
100. orrectly The rest cannot be used Warning Did not receive Some transmit requests that were started did completions for all TX not complete in a reasonable time during requests unloading of the driver This is most likely due to a fatal fault in the adapter Warning VMware doesn t support The driver received a packet larger than 8192 multiple frags Dropping bytes in multiple fragments Since VMware the pkt Len d gt frag does not support such fragments in skb this size 8192 packet is ignored Since the OneConnect interfaces do not accept MTUs larger than 8178 packets larger than 8192 are not expected Warning Invalid value of bps An ioctl to set the QoS parameter bits Must be 0 to 100 seconds encoding value outside of 0 to 100 was attempted The request is ignored and the QoS setting is not changed Warning pci enable msix The call to enable MSI X for the OneConnect failed Not using MSIx UCNA NIC driver interface failed In ESX Server 3 5 update 1 and later versions MSI X is not enabled if NetQueues are not enabled Try enabling NetQueues Even if MSI X is not enabled the driver can continue to work using INT X interrupts Error Failed to map PCI BARS Call to map PCI BAR registers of the OneConnect UCNA failed This is a rare failure that may occur due to system resource limitations Warning Invalid EQ ResourceID The OneConnect UCNA reported an event lt DDD gt with an invalid resource ID This error should not happen n
101. ot determine what type of link event occurred DATA None SEVERITY Information LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network May indicate a possible hardware or firmware problem Ipfc_mes1308 Menlo Maint Mode Link Up Event lt eventTag gt rcvd DESCRIPTION The driver received a Menlo Maint Mode Link Up Event DATA link event tag SEVERITY Information LOG LOG_LINK_EVENT verbose ACTION None required Ipfc_mes1309 Menlo Maint Mode Link Down Event lt evTag gt rcvd Data lt fc_evTag gt lt hba_state gt lt fc_flag gt DESCRIPTION The driver received a Menlo Maint Mode Link down Event DATA link event tag SEVERITY Information LOG Always ACTION None required Ipfe_mes1310 FCoE is running golden firmware Update immediately DESCRIPTION The FCoE card requires a firmware update DATA link event tag SEVERITY Error LOG Always ACTION Firmware update required Emulex Drivers for VMware ESX 3 5 User Manual Page 80 gt EMULEX Ipfc_mes1311 FCoE hba port in diagnostic mode Operational use suspended DESCRIPTION The HBA port is not operational while in diagnostic mode DATA None SEVERITY Error LOG Always ACTION Firmware update required Ipfe_mes1312 FCoE chip is running unknown firmware lt ft gt DESCRIPTION The FCoE card requires a firmware update DATA firmware tag SEVERITY Error LOG Alwa
102. ould not be allocated DATA 1 vport instance SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Ipfc_mes1807 VPort FDISC did not complete in time allotted DESCRIPTION The VPort s FDISC did not complete in the timeout period DATA None SEVERITY Warning LOG LOG_VPORT verbose ACTION This could be a fabric issue with a large vport count If problems persist contact Emulex Technical Support Ipfc_mes1808 Successfully created VPort vpi lt vpi gt DID lt vport DID gt Type lt port_type gt State lt port_state gt DESCRIPTION Successfully created vport display vital data DATA 1 vpi 2 vport DID 3 port_type 4 port_state SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1809 Unallowed delete of physical vport from vport_delete DESCRIPTION The physical vport belongs to the physical host DATA 1 vport DID 2 port_type 3 port_state SEVERITY Error LOG Always ACTION None required Ipfc_mes1810 Vport getinfo on vpi lt vpi gt DID lt DID gt DESCRIPTION The vport is returning vport data elements to the caller DATA 1 fail_reason 2 prev fail reason 3 vports max 4 vports inuse 5 linktype 6 port_state SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1811 VPort delete requested on vport DID lt DID gt vpi lt vpi gt state lt port_state gt DESCRIPTION A request to delete a vport is executing The dri
103. p_cnt 2 blp 3 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0907 Add NPort lt did gt to MAP list scsiid lt sid gt DESCRIPTION The driver is putting the node table entry on the mapped list DATA 1 map_cnt 2 blp 3 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0908 FIND node DID bind DESCRIPTION The driver is searching for a node table entry on the binding list based on the DID DATA 1 nlp 2 nlp_DID 3 nlp_flag 4 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mesO909 Removing default rpi on vpi lt vpi gt DESCRIPTION The driver is searching for a node table entry on the binding list based on the DID DATA 1 vport DID 2 rport DID 3 nlp_flag 4 status SEVERITY Information LOG_NODE verbose ACTION None required Ipfc_mes0910 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on the DID DATA 1 nlp 2 nip_DID 3 nlp_flag 4 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required Ipfc_mes0911 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on the DID DATA 1 nlp 2 nlp_DID 3 nlp_flag 4 state xri type rpi SEVERITY Information LOG LOG_NODE verbose ACTION
104. parameter for Scan down is out of range DATA 1 totiocb 2 MAX_SLI2_lOCB SEVERITY Error LOG Always ACTION This is a software driver error If this problem persists report these errors to Technical Support Ipfc_mes0463 Port max temp exceeded lt temp gt taking port offline DESCRIPTION The HBA port is in an overtemperature condition and must be shutdown DATA 1 status 2 status1 3 status2 SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0464 Adapter failed to init Retry in SLI 2 mode mbxCmd lt cmd gt CONFIG_PORT mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing CONFIG_PORT mailbox command DATA 1 hbainit SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If this problem persists report these errors to Technical Support Ipfc_mes0465 Adapter failed to init retry mbxCmd lt cmd gt CONFIG_PORT mbxstatus lt status gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_PORT mailbox command DATA 1 hbainit SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0466 Defer error condition har lt Host Att Reg gt hsr lt Host Stat Reg gt DESCRIPTION Defer error condition detect
105. plete entry error DATA 1 wcqe status 2 hardware status 3 total data placed 4 word3 of the wcqe SEVERITY Information LOG LOG_INIT verbose ACTION None required Ipfc_mes4547 Read serdes parameter failed to allocate mailbox memory DESCRIPTION Read SerDes parameter failed to allocate mailbox memory DATA None SEVERITY Error LOG Always ACTION The driver failed to allocate mailbox command memory for reading the adapter region 23 to determine whether the link has been disabled This may result in enabling the adapter port which may have been permanently disabled by the management stack If this condition persists contact Technical Support Ipfc_mes4548 Read link state failed to read config region 23 DESCRIPTION Read link state failed to issue read config region 23 mailbox command DATA 1 rc 2 status SEVERITY Error LOG Always ACTION The driver failed to issue a mailbox command for reading the adapter region 23 to determine whether the link has been disabled This may result in enabling the adapter port which may have been permanently disabled by the management stack If this condition persists contact Technical Support Ipfc_mes4549 ReceiveQ error DESCRIPTION Put Receive Queue Entry RQE to Receive Queue returned error DATA 1 rc SEVERITY Error LOG Always ACTION None required However if problems persist reset the HBA or reboot the system when necessary lpfc_mes4550 Reset HBA
106. r values are in effect it prints the current value ESX Server Network Driver The following section includes examples of the various configuration parameters for improving the performance of the OneConnect network drivers for ESX Server Enabling vmxnet Emulation Jumbo Frames and TSO The OneConnect UCNA supports jumbo frames and TSO Both jumbo frames and TSO are necessary for optimal performance with the OneConnect UCNA Also using the vmxnet NIC emulator can provide a significant performance boost These features are not enabled by default in ESX Server To enable these features 1 Log into the console operating system COS 2 For each guest operating system there is a vmx file in the path vmts volumes lt VM NAME gt VM NAME gt vmx where lt VM NAME gt is the name of the VM Emulex Drivers for VMware ESX 3 5 User Manual Page 9 gt EMULEX 3 For each VM edit this file and add the following line for the OneConnect driver interface ethernet0O features 15 4 To enable vmxnet emulation add the following line for the OneConnect driver interface ethernet0O virtualDev vmxnet 5 Restart the VMs The above steps assume that eth0O is the interface added to the VM from the OneConnect Network Note The use of vmx NIC emulation requires VMware Tools to be installed in the guest operating systems For instructions on how to install the VMware Tools in guest operating systems refer to the Support sect
107. re driver firmware or hardware problem Report these errors to Technical Support Ipfc_mes0313 Ring lt ringno gt handler unexpected Rctl lt Rctl gt Type lt Type gt received DESCRIPTION The Rctl Type of a received frame did not match any for the configured masks for the specified ring DATA 1 ring number 2 rctl 3 type SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support Ipfc_mes0314 Ring lt ringno gt issue portCmdGet lt portCmdGet gt is bigger then cmd ring lt portCmdMax gt DESCRIPTION The port cmd ring get index is greater than the size of cmd ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support Ipfc_mes0315 Ring lt ringno gt issue portCmdGet lt portCmdGet gt is bigger then cmd ring lt portCmdMax gt DESCRIPTION The port cmd ring get index is greater than the size of cmd ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support Ipfc_mes0316 Cmd ring lt ringno gt put iotag lt iotag gt greater then configured max lt fast_iotag gt wdO0 lt icmd gt DESCRIPTION The assigned I O iotag is greater than the allowed maximum DATA None SEVERITY Error LOG
108. rescue timer DATA 1 tmo 2 disctmo 3 fc_plogi_cnt 4 fc_adisc_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0248 Cancel Discovery Timer state lt hba_state gt DESCRIPTION Cancel the device discovery RSCN rescue timer DATA 1 fc_flag 2 rc 3 fc_plogi_cnt 4 fc_adisc_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0249 Unsupported Addressing Mode lt i gt on NPort lt nip_DID gt Tgt lt sid gt DESCRIPTION The driver issued a REPORT_LUN SCSI command to a FCP target DATA None SEVERITY Warning LOG LOG_DISCOVERY LOG_FCP verbose ACTION Check configuration of target Driver will default to peripheral addressing mode Ipfc_mes0250 EXPIRED nodev timer DESCRIPTION A device disappeared for greater than the configuration parameter lpfc_nodev_tmo seconds All I O associated with this device will fail DATA 1 dev_did 2 scsi_id 3 rpi SEVERITY Error LOG Always ACTION Check physical connections to Fibre Channel network and the state of the remote PortlD Ipfc_mes0251 Unrecognized event type while flushing task list DESCRIPTION The driver found an unsupported event type when flushing the event list DATA 1 evt 2 arg1 3 arg2 SEVERITY Error LOG Always ACTION If this condition persists contact Emulex Technical Support Ipfc_mes0252 Unrecognized event type found in task
109. ries No action needed Ipfc_mes0277 Failed to get the non embedded SGE virtual address DESCRIPTION Failed to get the SGE virtual address for the non embedded mailbox command for management plane query DATA None SEVERITY Error LOG Always ACTION This is not part of the driver basic discovery process and only affects the management stack query to obtain FCF entries No action needed Emulex Drivers for VMware ESX 3 5 User Manual Page 45 gt G EMULEX Ipfc_mes0278 READ_FCF_RECORD mailbox failed DESCRIPTION Issue READ_FCF_RECORD mailbox returned status failure for management plane query DATA 1 status 2 add_status SEVERITY Error LOG Always ACTION This is not part of the driver basic discovery process and only affects the management stack query to obtain FCF entries No action needed Ipfc_mes0279 UNREG_VFI mbxStatus error DESCRIPTION Unregister VFI mailbox command returned with failure status DATA 1 mbxStatus 2 HBA state SEVERITY Error LOG Always ACTION Check fabric and interface configuration Ipfc_mes0280 UNREG_FCFI mbxStatus error DESCRIPTION Unregister FCFI mailbox command returned with failure status DATA 1 mbxStatus 2 HBA state SEVERITY Error LOG Always ACTION Check fabric and interface configuration Ipfc_mes0281 Failed to allocate mbox for UNREG_VFI cmd DESCRIPTION Failed to allocate memory for issuing UNREG_VFI mailbox command DATA 1 HBA state SEVERI
110. s Support for the ANSI INCITS t11 standard for NPIV deployment in ESX starting with release 3 5 For LP11 and LPe11 series adapters the version 2 72a2 firmware increases the number of vports from 8 to 16 Supports NPIV for CNAs Emulex Drivers for VMware ESX 3 5 User Manual Page 1 Prerequisites gt G EMULEX The following table lists the support relationship between VMware ESX releases and Emulex drivers Refer to VMware s vi3_io_guide pdf for more detailed information Table 1 Emulex Driver Support in ESX Releases VMware ESX Release Emulex Driver Version ESX 2 5 4 Ipfc_7 3 2_vmw3 4 Gb s provided with ESX 2 5 4 Patch 4 ESX 2 5 5 Ipfc_7 3 2_vmw4 2 and 4 Gb s ESX 3 0 0 Ipfc_7 1 14_vmw1 2 Gb s Ipfc_7 3 2_vmw1 4 Gb s ESX 3 0 1 Ipfc_7 3 2_vmw2 2 and 4 Gb s ESX 3 0 2 Ipfc_7 3 2_vmw4 2 and 4 Gb s ESX 3 5 0 Ipfc_7 4 0 13 2 and 4 Gb s ESX 3 5 Update 1 Ipfc_7 4 0 13 1 2 and 4 Gb s ESX 3 5 Update 2 Ipfc_7 4 0 13 2 2 4 and 8 Gb s Asynchronous CNA Release for ESX 3 5 Update 2 Ipfc_7 4 0 31 FCoE ESX 3 5 Update 4 Ipfc_7 4 0 40 2 4 8 Gb s Asynchronous CNA Release for ESX 3 5 Update 4 Ipfc_7 4 0 41 FCoE ESX 3 5 Update 5 Ipfc_7 4 0 52 FC FCoE be2_2 101 374 0 NIC be2_2 101 374 0 iSCSI Compatibility For a list of adapters that are compatible with this driver see the driver s Downloads page on the Emulex Web site For
111. s for a particular purpose Emulex may make improvements and changes to the product described in this manual at any time and without any notice Emulex assumes no responsibility for its use nor for any infringements of patents or other rights of third parties that may result Periodic changes are made to information contained herein although these changes will be incorporated into new editions of this manual Emulex disclaims any undertaking to give notice of such changes Emulex 3333 Susan Street Costa Mesa CA 92626 Copyright 2003 2009 ServerEngines Corporation TRADEMARKS ServerEngines the ServerEngines logo and BladeEngine 2 are trademarks or registered trademarks of ServerEngines Corporation Microsoft Windows Windows XP Windows 2003 and Windows 2008 are U S registered trademarks of Microsoft Corporation Emulex Drivers for VMware ESX 3 5 User Manual Page ii Table of Contents gt EMULEX IMIStAN AION sessen EE 1 Divo IMT OM ATOM Gale cae eats ees ees ees ee ee we eu ee tema 1 Supported Features ccccceeeeeeeeeeceeeeeeeeeeeceeeeaaaeeeeeeeeeeeeaaeaeeeeeeeeeesaeasaaeeeeees 1 New Features in this REl6asSe ccecccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeeetenss 1 Prerequisites ccccceeeeeeeeeeeceeeeeeeeeeeeeeeeaaaeaeeeeeeeeeecaaeaeeeeeeeeeeeeaaaeeeeeeeeeeeaaaeees 2 COMM Peat DIN a 2a Sakae Sade a a eee Re ae a a a a a a ae a Na Saha a a aaa ahaha deka hadetededadate 2 KMOWMN ISSUG
112. s persist report these errors to Technical Support Ipfc_mes0471 Unsupported CQ count of d DESCRIPTION The event queue cannot be initialized with the specified count DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0472 CQ_CREATE mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be created DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 64 gt G EMULEX Ipfc_mes0473 Unsupported MQ count of d DESCRIPTION The queue cannot be initialized with the specified count DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0474 MQ_CREATE mailbox failed stat lt x x gt add_stat lt x x gt mbx_stat lt x x gt DESCRIPTION The queue cannot be created DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0475 Unsupported RQ count of d at d DESCRIPTION The queue cannot be initialized with the specified count D
113. scovery Ipfc_mes0263 NameServer Rsp Error DESCRIPTION The driver received a nameserver response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Ipfc_mes0265 Vport NameServer login no memory DESCRIPTION Remote node memory allocation failed for logging into name server for a VPort DATA 1 vid SEVERITY Error LOG Always ACTION Check the driver memory utilization and reboot the system if necessary If this condition persists contact Emulex Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 43 gt G EMULEX Ipfc_mes0266 Vport cannot issue NameServer login DESCRIPTION Issue PLOGI to VPort remote nameserver failed DATA 1 vid SEVERITY Error LOG Always ACTION Check the fabric configuration and reboot the system if necessary If this condition persists contact Emulex Technical Support Ipfc_mes0267 Adapter message DESCRIPTION When the response IOCB carrys an unknown IOCB type and the upper layer command is an adapter message it logs the adapter message returned from the adapter DATA Message returned from the adapter SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed the driver will recover from this and continue with normal operation Ip
114. se interfaces are configured as uplinks in two separate vSwitches the VMs in each of these switches are in separate networks with no network path between them and pinging between the VMs in two groups will fail If you want all these VMs to be in the same network configure them as teaming uplinks to one vSwitch option Each of the vmnics vmnicO to vmnic7 must be configured in a separate vSwitch In this configuration there is no network path between the vSwitches and pinging between these VMs will not work ESX Server Event Error Log Messages Retrieving ESX Server NIC Error Log Codes For ESX Server systems the OneConnect NIC be2net driver generates error codes to the var log vmkernel log file The vmkernel log file is an ASCII text file and can be viewed and searched with a text editor such as vi The vmkernel log file is automatically rotated as it gets larger and the rotated log files are named vmkernel x where x is an integer To search the log file for error messages at the command prompt type cd var log vi vmkernel For example you may see the following message Sep 9 19 48 04 esx server vmkernel BladeEngine 2 Net Driver Did not receive completions for all TX requests ESX Server NIC Event Log Entries The following is a list of ESX Server 3 5 network event log error messages It includes the severity of the error the message displayed and the message description When reporting a problem with th
115. sponse was received DATA None SEVERITY Information LOG LOG_IP verbose ACTION No action needed informational Ipfc_mes0601 FARP REQ received from DID lt did gt DESCRIPTION A FARP ELS command request was received DATA None SEVERITY Information LOG LOG IP verbose ACTION No action needed informational Ipfc_mes0610 FARP Request sent to remote DID gt G EMULEX DESCRIPTION A send to a remote IP address has no node in the drivers nodelists Send a FARP request to obtain the node s HW address DATA 1 IEEE 0 2 IEEE 1 3 IEEE 2 4 IEEE 3 5 IEEE 4 6 IEEE 5 SEVERITY Information LOG LOG _IP verbose ACTION Issue FARP and wait for PLOGI from remote node Emulex Drivers for VMware ESX 3 5 User Manual Page 69 gt G EMULEX FCP Traffic History 0700 0799 Ipfc_mes0701 Issue Abort Task Set to TGT lt num gt LUN lt num gt DESCRIPTION The SCSI layer detected that it needs to abort all I O to a specific device This results in an FCP Task Management command to abort the I O in progress DATA 1 scsi_id 2 lun_id 3 rpi 4 flags SEVERITY Information LOG LOG_FCP verbose ACTION Check the state of the device in question Ipfc_mes0702 Issue Target Reset to TGT lt num gt DESCRIPTION The SCSI layer detected that it needs to abort all I O to a specific target This results in an FCP Task Management command to abort the I O in progress DATA 1 rpi 2 flags SEVERITY
116. t type cd var log vi vmkernel For example you may see the following message Sep 9 19 48 04 esx server vmkernel BladeEngine 2 iSCSI Driver The be2iscsi driver received a Task Management Function that is not supported and rejected this request The error log entry immediately following this entry will indicate the TMF function code that was rejected Emulex Drivers for VMware ESX 3 5 User Manual Page 20 ESX Server iSCSI Error Log Code Entries gt G EMULEX The following is a brief description of the error log codes generated by the OneConnect iSCSI ESX Server driver It includes the error code the message displayed and the meaning of the message and the recommended resolution Table 7 ESX Server iSCSI Error Log Code Entries Message Id Message Recommended Resolution 0x31880001 The be2iscsi driver This failure may be due to the firmware not failed to load because being present or running currently This failure initialization failed may also indicate a hardware issue during a power management bootup 0x3184000c The be2iscsi driver This failure may indicate a low memory failed was unable to map condition or a hardware error one or more PCI Base Address Register and hence failed to load 0x3184000b The be2iscsi driver Check the output of esxcfg module g ignored a configuration be2iscsi for any new entries added to driver entry since the entry was Parameters The invali
117. to Technical Support Ipfc_mes0324 Adapter initialization error moxCmd lt cmd gt READ_NVPARM mbxStatus lt status gt DESCRIPTION A read nvparams mailbox command failed during port configuration DATA 1 Mailbox Command 2 Mailbox Command Status SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem Report these errors to Technical Support Ipfc_mes0325 Rsp ring lt ringno gt error OCB DESCRIPTION Received an IOCB response error DATA 1 wdO 2 wd1 3 wd2 4 wd3 5 wd4 6 wd5 7 wd6 8 wd7 SEVERITY Warning LOG LOG_SLI verbose ACTION This error could indicate a software driver problem If problems persist report these errors to Technical Support Ipfc_mes0326 Reset HBA DESCRIPTION The HBA has been reset DATA 1 hba_state 2 sli_flag SEVERITY Information LOG LOG_SLI verbose ACTION No action needed informational Ipfc_mes0327 High priority OCB cmd x x completed in d jiffies DESCRIPTION Make all high priority OCBs completion times available to console DATA 1 ulpCommand 2 wait time in jiffies SEVERITY Information LOG LOG_SLI ACTION No action needed informational Emulex Drivers for VMware ESX 3 5 User Manual Page 52 gt G EMULEX lpfc__mes0328 High priority IOCB cmd x x exceeded allotted wait time of d jiffies DESCRIPTION The driver didn t get a completion for a high priority IOCB within the wait time allotted DATA 1
118. tus reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0437 Adapter failed to init chipset status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Emulex Drivers for VMware ESX 3 5 User Manual Page 59 gt G EMULEX lpfc__mes0438 Adapter failed to init chipset status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0439 Adapter failed to init mbxCmd lt cmd gt READ_REV mbxStatus lt status gt DESCRIPTION Adapter initialization failed when issuing a READ_REV mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Ipfc_mes0440 Adapter failed to init mbxCmd lt cmd gt READ_REV detected outdated firmware DESCRIPTI
119. ueEnabled FALSE the feature is disabled e To enable NetQueue run the following command ESX esxcfg advcfg k TRUE netNetqueueEnabled Reboot the ESX Server for the change to take effect How ESX Server Creates and Names Interfaces The OneConnect NIC driver supports a maximum of four UCNAs per system For dual channel UCNAs running in standard operating mode the OneConnect driver creates two interfaces one for each physical port The first and second interfaces are respectively named vmnicO and vmnic1 assuming there are no other network interfaces in your configuration The same applies to virtual NIC vNIC capable UCNAs when vNIC mode is disabled in the system BIOS When vNIC mode is enabled in the system BIOS for those boards that support vNIC the OneConnect driver creates eight interfaces four for each physical port The interfaces are labeled vmnicO through vmnic7 assuming there are no other network interfaces in your configuration All 8 vNICs are fully functional and support the same feature set as a standard NIC The vNICs can also be linked to a virtual switch in the same way Emulex Drivers for VMware ESX 3 5 User Manual Page 8 gt EMULEX esxcfg nics 1 list recognized nics esxcfg vswitch 1 list available vswitches esxcfg vswitch a vSwitcho create vSwitcho esxcfg vswitch A VMNet0O vSwitcho create virtual machine network VMNetO and add it to vSwitcho esxcfg vswitch L vmnicO vSwitc
120. ulpCommand 2 allotted wait time in jiffies SEVERITY Error LOG Always ACTION Depending on the ulpCommand and the associated task command there could be an oversubscription condition in the SAN If problems persist report these error to Technical Support Ipfc_mes0329 Ring d handler unexpected ASYNC_STATUS evt_code 0x x DESCRIPTION The port has issued an unexpected asynchronous event code to the driver DATA IOCB 0 15 SEVERITY Error LOG Always ACTION This error could indicate a driver or firmware problem If problems persist report these error to Technical Support Ipfc_mes0330 Command IOCB lookup miss on Fast lookup array DESCRIPTION The loTag provided did not result in a valid command IOCB in the fast lookup array DATA 1 loTag 2 Ring number SEVERITY Error LOG Always ACTION This error could indicate a driver or firmware problem If problems persist report these error to Technical Support Ipfc_mes0331 Ring d handler unexpected ASYNC_STATUS iocb received evt_code 0x x DESCRIPTION The port has issued an unexpected asynchronous event code to the driver DATA IOCB 0 15 SEVERITY Error LOG LOG_SLI ACTION This error could indicate a hardware firmware problem If problems persist report these error to Technical Support Ipfc_mes0332 REG_VPI failed DESCRIPTION reg_rpi mailbox failed DATA 1 status SEVERITY Error LOG Always ACTION Delete VPorts or increase Ipfc_max_vpi Ipfc_
121. ut of range Valid Range is 0 1 Default Value 0 Note d represents a signed integer outside of the valid range The driver returns a number in the actual warning message Any other messages returned are similar to the following message be2iscsi FUNCTION NAME LINE MESSAGE For example be2iscsi 1088 kmalloc failed You are directed to find the function FUNCTION NAME at line LINE in the source Emulex Drivers for VMware ESX 3 5 User Manual Using Page 25 56 EMULEX LPFC Log Messages Introduction Log messages are organized into logical groups based on code functionality within the Fibre Channel driver Each group consists of a block of 100 log message numbers Most groups require a single block of 100 message numbers however some groups INIT FCP require two blocks The groups and the associated number ranges are defined in the Message Log table below The preamble string shown in the Message Log table is displayed as part of the log message The lower case x of the preamble string defines the severity of the log message The x will be replaced by one of five lower case letters Those letters are defined in the Severity Code table Severity Codes Information and warning messages can be turned ON or OFF by setting resetting the appropriate mask bit s in the variable Ipfc_log_verbose located in the driver configuration module Ipfc conf c By default both information and warning messa
122. ver dumps the vport s state and node counts DATA 1 plogi cnt 2 adisc cnt 3 unmapped cnt 4 mapped cnt SEVERITY Information LOG LOG_VPORT verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 83 gt G EMULEX Ipfc_mes1812 VPort fabric LOGO didn t complete treating as failure DESCRIPTION The VPort s fabric logout didn t complete Continuing vport teardown DATA 1 vport DID SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Ipfc_mes1813 VPort could located target node binding DESCRIPTION The vport was called to remove a target given a target ID but the vport could not locate a node binding by TGTID DATA 1 vport vpi 2 vport DID 3 tgtid SEVERITY Error LOG Always ACTION Contact Emulex Technical Support Ipfc_mes1814 Vport discovery quiesce wait on vpi DESCRIPTION The vport node discovery is active DATA 1 port_state 2 fc_flag 3 num_disc_nodes 4 fc_plogi_cnt 5 fc_adisc_cnt 6 fe_map_cnt SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1815 Vport discovery quiesce cmplt on vpi lt vpi gt DESCRIPTION The vport node discovery has completed DATA 1 port_state 2 fc_flag 3 fe_map_cnt SEVERITY Information LOG LOG_VPORT verbose ACTION None required Ipfc_mes1816 Vport discovery quiesce timeout on vpi lt vpi gt DESCRIPTION The vport node discovery timed out waiting to quiesce DATA
123. vice for The operating system call to enable the BE adapter lt DD gt failed OneConnect UCNA failed Error Could not set PCI DMA The operating system call to set the DMA Mask mask failed Error BladeEngine init failed The initialization of the OneConnect UCNA failed Warning Unable to get BE Firmware The firmware command to get the version Version number failed Most likely due to incompatible firmware Warning alloc_skb failed Try The driver could not allocate an skb to pass a increasing received frame to the stack A transient failure netPktHeapMaxSize can be ignored If this message is often observed try increasing netPktHeapMaxSize For example to set the size to 256MB run esxcfig advcfg k 256 netPktHeapMaxSize then reboot the system Warning Invalid MTU requested An invalid MTU size is in the MTU Must be between lt DDD gt and configuration ioctl The MTU will not be lt DDD gt bytes changed Information MTU changed from lt DDD gt to The MTU size changed as requested lt DDD gt Warning Unable to get pause frame The firmware command to get the pause settings frame settings failed Warning Unable to set pause frame The firmware command to set the pause frame settings failed Emulex Drivers for VMware ESX 3 5 User Manual Page 19 Table 6 ESX Server NIC Event Log Entries Continued gt G EMULEX Severity Message Displayed Description Information Active port changed due to VL
124. ys ACTION Firmware update may be required Ipfc_mes1313 Invalid FRU data found on adapter DESCRIPTION Return adapter to Emulex for repair DATA None SEVERITY Error LOG Always ACTION Return adapter to Emulex for repair Ipfc_mes1314 Adapter Link is disabled DESCRIPTION The software has disabled the adapter link DATA None SEVERITY Error LOG Always ACTION Use the management software to re enable the link Ipfc_mes1315 Adapter failed DOWN_LINK DESCRIPTION The adapter was unable to disable the link DATA mailbox status SEVERITY Error LOG Always ACTION May indicate a hardware or firmware problem If this problem persists report these errors to Technical Support LIBDFC Events 1600 1699 Ipfc_mes1600 ioctl entry DESCRIPTION Use to trace IOCTLs from LIBDFC Logged on completion DATA 1 cmd code 2 return code 3 return count SEVERITY Information LOG LOG_LIBDFC verbose ACTION None required Emulex Drivers for VMware ESX 3 5 User Manual Page 81 gt G EMULEX VPort Events 1800 1899 Ipfc_mes1800 Failed to create vport Insufficient VPIs DESCRIPTION There are no VPIs available to create a vport Either the physical port does not support VPIs or all available VPIs are in use DATA 1 vpi 2 max_vpi 3 avail_vpi SEVERITY Error LOG Always ACTION Delete unused unneeded vports If problems persist report error to Emulex Technical Support Ipfc_mes1801 Failed to