Home
User Manual
Contents
1. 0 cc eee ees 5 Adjustable Castors 224242000 64466 bev or cade OE BE BREED 5 Castor Mounting Plates 0 0 cece eee 5 Positioning the Cabinet 0 0 0 00 6 LOCAUON sha iss tans Khe aed EK ELS e 6 Ventilation N 64444 N EE 6 sesde des AR AE AT EE ER EK N N 6 n le EN N EE OE RE EE EE OP EE 7 Loading PIrOduel sies EER RES ERE OASE RES DUE DA ED 7 el ske e ER EE EE 8 EE N EO EE IE 8 2 Operation Automatic Start Up ss se RE EER RE MEE RE SR RR RE RE ese EER EE 9 Refrigeration Unit SESSE SE EE SE ees 9 Electronic Controller SESSE SEE SES SES ES SE SS ee 9 Gabinet OGNUNO ss ees sd 02 RES bad oe ERA Se RE DEE N DR 9 Electronic Controller SESSE ee eee 10 Controller Display 0 0 SEE SE SE ee ee 10 Controller Operation SEE SS EE eee 11 Controller Alarms SESSE ccc ee eee 11 dele site ed oe ARE OE EE OE ee ERE ee N 12 Siel sae cub woes EE OE N OE FEE OE Bey ean NG 14 Manual Defrost sie sewe are hu dam Mara Ged ar ea de oe AE N BEE 4 14 Continuous Refrigeration EE ESE EE eee 14 3 Servicing Belge se co dar ce OE N OE EE ee ee 15 Cabinet Interior Lights 0 0 0 0 cece eee 15 ClCENING N EE EE bobo EE eee ee 16 6e ASE ER N FEES EE EE 16 Condenser Coil EE SEE ee eee ee 16 SIIGING COVES susse ocd head een da eee een Seas A 17 Food Preparation Pans 0 00 cece eee 17 WAVING Soa ih wise ER EE N er ke 18 Cabinet Wiring Diagram 0 SEE SS EE eee 1
2. Controller The operation of the chiller is controlled by a pre programmed Operation microprocessor The Microprocessor display indicates the temperature of the cabinet ambient probe except during a defrost where the temperature of the cabinet probe is locked in and during an alarm condition At alarm activation the display indicates the type of alarm signal and an audible alarm sounds The alarm can be muted by pressing the PRG mute key on the controller Controller A flashing LED indicates an alarm The following is a list of alarms the Alarms controller displays Alarm code Description J Faulty ambient probe Faulty defrost probe High pressure fault Low minimum temperature alarm High maximum temperature alarm Defrost timed out w aa Ga es Ge feet Ga A ee Pen uN ee mel Paul ee eu Data acquisition failure EE NOTE Alarm HI may activate during initial pull down cycle after being first powered up The alarm can be muted and will automatically reset when the cabinet passes the alarm setpoint To reset an alarm Clean the condenser radiator fins and remove any obstruction to the airflow Ensure the cabinet environment is below 35 C wo N Unplug the cabinet from the power supply for 1 minute then re connect to the power supply iN Check cabinet product loading to ensure ventilation slots are not blocked and that product does not overhang the shelves g
3. If alarm persists contact a SKOPE authorised refrigeration service agent Operation 11 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Programming To prevent unauthorised modification the controller is factory set with the keypad locked To make permanent program changes including changing the setpoint and forcing a manual defrost the keypad must first be unlocked by entering an access code Entering the access code allows the keypad to be unlocked and locked by altering parameter H2 see below for instructions on how to unlock the keypad Controller lock parameter Parameter Setting Description H2 oo Keypad locked H2 Keypad unlocked After making program changes it is recommended that the keypad is locked see over page for instructions on how to lock the keypad To unlock the keypad 1 Press and hold both the PRG and SEL keys simultaneously for more than 5 seconds until 00 is displayed 2 Press the UP aux key until 22 is displayed 3 Press the SEL key to confirm selection The first parameter IC is displayed 4 Press the DOWN def key twice until H2 is displayed 5 Press the SEL key to display the value of the parameter 6 Press the UP aux key to increase or the DOWN def key to decrease until 01 is displayed 7 Press the SEL key to accept the value 8 Press the PRG key to lock in the new value and to exit program
4. cover off the bottom hinge pin 2 Switch off the cabinet isolating switch and unplug the blue power supply plug from underneath the isolating socket box 3 Disconnect the cabinet supply plug from underneath the wiring junction box on the front of the refrigeration unit 4 Remove the top clamp screw from the clamp mechanism on top of the unit 22 Servicing User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller 5 Pull the top clamp mechanism fully forward into the relocation position on the front flange of the cabinet this keeps the mechanism up out of the way 6 Remove the bottom clamp screw from the front of the refrigeration unit 7 Pull the bottom clamp lever forward while applying adequate force to the right hand side of the wiring junction box to disengage the unit from the cabinet wall the unit will need to move over approx 60mm 8 Carefully pull the refrigeration unit out from the unit compartment IMPORTANT When refitting the refrigeration unit refit the bottom clamp screw first before fitting the top clamp screw and prior to refitting ensure that all seals are in good condition Servicing 23 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller 24 Troubleshooting Complaint Possible Cause 1 Cabinet not e Loss of power supply operating and no controller display 2 Cabinet lights Failed LED light t
5. 42 Operation User Manual Operation User Manual IC is displayed SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller To lock the keypad Press and hold both the PRG and SEL keys simultaneously for more than 5 seconds until 00 is displayed Press the UP aux key until 22 is displayed Press the SEL key to confirm selection The first parameter Press the DOWN def key twice until H2 is displayed Press the SEL key to display the value of the parameter Press the UP aux key to increase or the DOWN def key to decrease until 00 is displayed Press the SEL key to accept the value Press the PRG key to lock in the new value and to exit program 13 SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Setpoint The chiller setpoint is factory set at 1 5 C If necessary the standard setting can be adjusted between 0 C and 6 C SKOPE do not recommend the setpoint be changed unless absolutely necessary and then only in small increments at a time To display the set point 1 Unlock the keypad 2 Press the SEL key for 1 second and the Set Point value will be displayed Freezer set point Factory setting 1 5 C Maximum 6 C Minimum 0 C To change the set point 1 Unlock the keypad 2 Press the SEL key for 1 second and the Setpoint value will be displayed On releasing the key the display will flash 3 To change the Setpoint va
6. 8 Refrigeration Unit Wiring Diagram 0 2 00 cee eee 20 Advanced Servicing aaa SEE SE tenes 22 Removing the Refrigeration Unit EE EE EE EE EE ee 22 Troubleshooting EE ESE SEE ee ee ee se 24 SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller iji User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller 1 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference o When the appliance is used by or near young children or infirm persons close supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit Do not probe any opening Only use this appliance with the voltage specified on the rating label Ensure the appliance has adequate ventilation as this is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel n Ifthe power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard o Ensure all necessary safety precautions are observed duri
7. N CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au
8. User Manual MAN67910 Rev 2 0 Feb 2012 SKOPE PEGASUS PG250 400 550Prep 2 Horizontal 1 1 Gastronorm INTEGRAL Prep Chiller SOPE Refrigeration SKOPE PEGASUS Horizontal Gastronorm Integral Prep Chiller PG250 400 550Prep 2 User Manual MAN67910 Rev 2 0 Feb 2012 2007 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SEKE E is a registered trademark of SKOPE Industries Limited SKOPE INDUSTRIES LIMITED Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner e Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer e Future owners of the product CONTENTS 1 Installation ide ER EE ER RE NE EE OE 4 Fitting the Legs or Castors naana cece eee eee 5 Adjustable Legs
9. able Leg Adjustable The adjustable castors screw into the castor mounting plates attached to the Castors bottom of the cabinet The two lockable castors should be fitted to the front of the cabinet see Figure 3 below and the non locking castors fitted to the rear see Figure 4 below The adjustable castors can adjust the cabinet height up to 15mm To adjust the height of each castor loosen the lock nut and turn the castor counter clockwise to raise the height or clockwise to lower Re tighten each lock nut after final adjustment has been made Castor Lock Nut Castor Mounting Plate Figure 3 Figure 4 Lockable Castor front Non Locking Castor rear Castor Ifthe chiller is intended to be mounted on a plinth the castor mounting Mounting plates attached to the bottom of the cabinet can be removed to provide a flat Plates bottom Each castor mounting plate is held in place by four pozi drive hexagon head screws see Figure 1 above Installation NE 5 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Location Ventilation Power Supply Positioning the Cabinet When positioning the cabinet avoid direct sunlight and warm draughts etc The cabinet must NOT be situated where it is affected by warm or hot air from adjacent equipment above 30 C as this will compromise the airflow and performance of the chiller The cabinet must be positioned on a level surface for the doors to shut and seal cor
10. ard in this range Portions A amp B Exclude Outer connected bench top heater wire for Prep cabinet item 29 included in Pizza cabinet only Portions A B amp D Exclude Outer connected bench top heater wire for Prep cabinet item 29 included in Pizza cabinet only Portions A B C amp D Exclude Outer connected bench top heater wire for Prep cabinet item 29 included in Pizza cabinet only Servicing 18 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller BU BN OG BU OO 00 00L EP e kke NA His IS Hi EA Ha If SS Hilde 9 49 de MIPE E EES VAYAN Om mm mm SE SE SE EE ME EE ME SE EE SE ME ME SE EE SE EE SE EE SE SE EE SE EE SE SE EE ME SE SE SE EE EE EE SE SE SE SE EE SE SE SE EE SE ME EE SE ME SE SE EE SE SE SE SE SE SE Sm N d Cabinet Wiring Component Key continued Wem Deseipton hem besip Spare bench top heater wire supply wires if available 22 Heated centre pillar assembly noigh 32 Refigeration unitencosue 23 Heated centre pilar fascia assembly 88 Meins isolation box assembly Not on REMOTE cabinets 24 Heated centre pilar back assembly 34 Mains supply fex with Pin plug 25 Cabnettascsa a Mains supply earth connection 26 Heated bench topassembly PPO isolation switch 27 Heated bench top assembly earth connection 37 amp Pole BLUE panel mou
11. lue press the UP aux or DOWN def keys 4 Press the SEL key to lock in the value and return to cabinet temperature The Setpoint value is stored even when the procedure is exited by waiting for the time out to expire Manual To start a manual defrost Defrost Unlock the keypad 2 Press and hold both the PRG and SEL keys simultaneously for more than 5 seconds until 00 is displayed Continuous To achieve a fast product temperature pull down activate continuous Refrigeration refrigeration mode To enter continuous refrigeration mode 1 Unlock the keypad 2 To achieve a fast product pull down press UP aux and DOWN def together down key first to initiate a Continuous Refrigeration mode 14 Operation User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller 3 Servicing Lighting Cabinet Depending on the model the cabinet interior is lit by one or two 5 Watt T8 Interior Lights LED tubes fitted behind the centre pillars To replace the interior LED light tube 1 Open the refrigeration compartment door and isolate the chiller from the power supply by switching off the mains isolation switch 2 Remove the diffuser by squeezing it until it is released from the housing and then push the diffuser out of the way 3 Rotate the LED tube until the pins on the ends of the tube align with the slots then slide it out Note access can be made easier by re
12. moving the shelves 4 Fita new LED tube and clip the diffuser back into place Servicing 15 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Cleaning Cabinet When necessary wipe both the interior and exterior of the cabinet with a damp cloth Ensure the cabinet is disconnected from the mains power supply before cleaning the cabinet CAUTION Disconnect the cabinet from the mains power supply before cleaning the condenser coil or washing the cabinet with water Condenser The condenser coil should be brushed clean once a month and blown clean Coil by qualified service personnel every six months Over time dust may accumulate within the condenser that cannot be removed with a brush If this occurs contact SKOPE to arrange for a SKOPE authorised service agent to clean the condenser with compressed air The condenser coil is located inside the refrigeration unit compartment and is accessed by opening the unit front cover hi sped peer ad gad gee Figure 8 Condenser Coil Sliding Covers At regular intervals the sliding covers guide rails air diffuser panels and food preparation pans should be removed from the cabinet and washed with soapy water To remove the sliding covers 1 Lift the cover up which will raise the guide rails allowing the covers to slide out 16 Servicing User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller To remove the guide
13. ng installation or removal of the refrigeration unit o The appliance is not designed to be stable while in motion Use extreme caution when moving or transporting it o Do not store explosive substances such as aerosol cans witha flammable propellant in this appliance CAUTION Never overload the power supply which could damage the chiller and product See the rating label inside the cabinet for the safe power supply and current draw WARNING Always disconnect the chiller from the mains power supply before cleaning or maintenance A Installation User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Fitting the Legs or Castors Packed inside the the cabinet is a set of adjustable height legs and a set of adjustable height castors Either of these sets can be fitted to the cabinet depending on specific height and manoeuvrability requirements The legs or castors should be fitted to the base of the cabinet before final positioning of the chiller Do not lay the chiller onto its back when fitting the legs or castors Adjustable The adjustable legs screw into the castor mounting plates attached to the Legs bottom of the cabinet The adjustable legs can adjust the cabinet height up to 30mm To adjust the height of each leg turn the black plastic foot at the bottom of the leg counter clockwise to raise the height or clockwise to lower see Figure 2 below Figure 1 Castor Mounting Plate Figure 2 Adjust
14. nt ENSTO socket isolation socket Bench top heater wire Prep otherwise Pizza 29 Outer bench top heater wire exists for Pizza cabinet only 39 Refrigeration unit enclosure earth connection Spare bench top heater wire not connected if available Wire Colour Key Pan oom fev oe WH White ro rea w ome Based upon IEC 757 Standard Servicing 19 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Refrigeration Unit Wiring Diagram Models UESO 6OACD Sleeve TO POWER INTERFACE Blue wire path for RH Refrig I Units Only Blue wire path for LH Refrig Units Only 9 BU oBK GNYE BN s og BN o RD 11 4 lt B IM GNYE OFB 3 LE denotes the motor direction as viewed from the lead end For refrigeration cabinet wiring details refer to Cabinet Wiring Diagram on the previous pages Wire Colour Key en Bown GY ov PRD Red WH White Based upon IEC 757 Standard 20 Servicing User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Refrigeration Unit Wiring Component Key Models UE50 60ACD wem pesepuen em Deere Refrigeration Unit Assembly Programmed Electronic Controller Unit Wiring Junction Box Evaporator Box Assembly Refrigeration Unit Supply Isolation Flex with 3 pin blue free i gt ENSTO plug fitted 25 Evaporator Box Exterior Earth Connection 3 Pole Blue Free ENSTO Plug Te
15. ord out from the rear compartment and connect to the power supply For convenience any surplus cord length may be left inside the cabinet compartment Once the chiller has been installed it can be disconnected from the mains power supply by turning off the cabinet isolating switch and unplugging the unit supply isolation flex located inside the refrigeration unit compartment see Figure 6 below Cabinet Isolating Switch Figure 5 Power Cord Figure 6 Isolating Switch WARNING Do NOT overload the power supply See the rating label inside the cabinet for power supply and current draw Installation User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Shelving The cabinet is supplied with two sets of shelves and shelf support brackets per door The shelves can be positioned at different heights to suit various products To fit the shelves 1 Unpack the shelving items from inside the cabinet 2 Establish the desired position for each of the shelves based on the height of the product intended to go on each shelf 3 Fit the shelf support brackets into the corresponding slots in both the front and back support rails Each shelf requires two support brackets 4 Slide each shelf into the support brackets Loading The chiller should be left running for 30 minutes before loading with product Product When loading the cabinet shelves with product o Allow air space around all the prod
16. rails and air diffuser panels 1 Remove the sliding covers and then lift both guide rails out The air diffuser panels can then be removed for cleaning Food The food preparation pans can be easily removed from the cabinet for Preparation cleaning PanS To remove the guide rails and air diffuser panels 1 Open the sliding door and lift the pan from the cabinet Servicing User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Wiring Cabinet Wiring Diagram For refrigeration unit wiring details refer to Refrigeration Unit Wiring Diagram on the following pages For remote refrigerators the mains isolation box assembly is part of the refrigeration unit assembly Cabinet Wiring Component Key Wem Deseipien hem oesi 4 FoeeNSTopug 14 Spare cabinet fascia heater wire supply wires avaliable 5 Cabinet supply flex earth connection sds 15 Bare cabinet fascia heater wire not if EE 6 Main cabinet chassis earth connection 16 Cabinet fascia heater wire chiller otherwise freezer 7 Flex tie to guide wires amp flexes on stepped cabinet front top 17 Heated iit centre pilar assembly e Cabinet wiring switched supp tay 18 Heated lit centre pillar fascia assembly 2 SFoeserewesseomeeorboek 19 Centre pilar fascia heater wire chiller otherwise freezer Model Key Cabinet Model Portions of Wiring Diagram Not offered as stand
17. rectly and to prevent the condensate tray from overflowing Adequate allowance should be made for door opening Always ensure that the top of the cabinet is shielded from impact and moisture with either a SKOPE provided bench top or with a custom or existing bench top For efficient operation of the chiller it is essential that adequate ventilation be provided around the front of the refrigeration unit Normal operating conditions should not exceed 30 C at 65 RH climatic class 5 lt is critical that the hot refrigeration exhaust air is not restricted and that it can easily flow out and away from the front of the cabinet Never store cardboard cartons or other items in front of the refrigeration unit The ventilation slots in the unit front cover must be kept clear at all times When installing the cabinet o Avoid direct sunlight and warm draughts etc o Allow adequate space for the door s and or drawer s to open fully o Ensure the cabinet is positioned on a level surface so the door s shut and seal correctly and to prevent the condensate tray from overflowing IMPORTANT For correct operation the sliding covers must stay on the cabinet and should cover the food preparation pans when not in use The chiller is supplied with a 1 8m flexible power cord and plug which for transit purposes is located inside a compartment in the rear of the cabinet see Figure 5 below Before final positioning of the chiller pull the power c
18. rminal Box for evaporator fan flex extension Evaporator Fan CW rotation LE for LH refrigeration unit Isolation Flex Earth Connection CCW rotation LE for RH unit ea 7 Pole Terminal Block Thermal Cutout Defrost Element 182W at 230V Electronic Controller Module 2 for UE50FAC refrigeration unit 3 for UE60FAC refrigeration unit e Eceronie Conor Connecion Gae 30 Peresi Sump Element BTW ae OS Fion Pressure Swier euroren or Cabinet Ambient Temperature Pree 18 Condenser Fan 4 Core Extension Flex with 4 pole ENSTO 40 Compressor Starting Capacitor socket fitted 19 Condenser Fan Capacitor At Condenser Fan with 4 pole ENSTO plug fitted rotation LE Unit Wiring Junction Box Cover Earth Connection 4 Pole Free ENSTO Plug 3 ER Electronic Controller Enclosure Ass y 4 Pole Free ENSTO Socket Servicing 241 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Advanced Servicing Servicing should be carried out by an authorised service agent Detailed service and spares information is available in the SKOPE Pegasus Service Manual and detailed technical information on the SKOPE ir32 Controller can be found in the SKOPE Pegasus Technicians Manual Removing the For ease of servicing the entire refrigeration unit can be removed from the Refrigeration cabinet Unit To remove the refrigeration unit 1 Open the unit cover Remove the cover from the cabinet by lifting the bottom corner of the
19. rt after approximately one minute The compressor will switch off when the cabinet internal temperature reaches approximately 1 5 C and on again at approximately 4 C Electronic When the cabinet is connected to the power supply Controller The electronic controller will display the cabinet temperature The Compressor and Fan LEDs will indicate when the compressor and evaporator fan are operating Cabinet The interior lighting will go on when a cabinet door is opened To replace an Lighting LED tube see service instructions on page 15 Operation 9 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Electronic Controller Controller SAY 940 a OG i Ss 8 si aa 11 11 me IO al aux Item leon Function Silences alarm buzzer 1 PRG mute Activates reset procedure 2 Displays setpoint in run mode Adjustment locked out 2 Activates and deactivates continuous refrigeration mode with def key Adjustment locked out 4 Activates manual defrost cycle Activates and deactivates continuous refrigeration mode with aux key 5 o Decimal point indicator Unused 7 Defrost cycle ON indicator 8 Evaporator fan ON indicator 9 o Continuous refrigeration mode ON indicator fast freeze 10 Compressor ON indicator 11 o Remote controller indicator O Q Operation User Manual 10 SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller
20. ube not operating e Cabinet ENSTO supply plug not plugged into control box 3 Power e Unit operating too hot consumption is higher than expected i e Cabinet doors are opened excessively e Sliding covers are left open for an excessive amount of time 4 Product is too Restricted cabinet airflow warm and spoiling e Temperature setpoint is too warm 5 Warm cabinet Blocked condenser temperatures and or Poor refrigeration unit compressor ventilation operating for long periods more than 1 hour Repair e Check mains power supply e Check that the cabinet isolating switch is turned on see page 6 e Replace LED light tube see page 15 e Reconnect plug see page 22 e Clean condenser Ensure the chiller is installed with good ventilation around the refrigeration unit e Keep door s open for minimum time e Keep covers opened for minimum time e Ensure product is not blocking airflow slots and the product is no closer than 75mm from the cabinet top e Adjust setpoint see page 14 e Clean condenser see page 16 e Ensure the cabinet is installed with good ventilation around the refrigeration unit See page 6 Servicing User Manual SKOPE Contacts SKOPE INDUSTRIES LIMITED NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIA
21. uct to ensure even cooling and efficient operation of the chiller o Do not allow products to overhang the front of the shelf as this could prevent the doors from shutting Leave an airspace of at least 75mm above product loaded on the top shelf Do not exceed a maximum loading of 20kg per shelf Remove some product if the shelves are flexing or bending Installation 7 User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller Sliding Covers The Prep chiller is supplied with the following quantity of food preparation pans and sliding covers Cabinet Model PG250Prep 2 4 PG400Prep 2 7 PG550Prep 2 For correct operation of the chiller the sliding covers must stay on the cabinet and should cover the food preparation pans when not in use Fit the sliding covers as per Figure 7 below Figure 7 Sliding Covers Installation User Manual SKOPE Pegasus Horizontal 1 1 Gastronorm Integral Prep Chiller 2 Operation Automatic Start Up Connect the cabinet to the mains power supply and check operation of the refrigeration unit electronic controller and cabinet lighting Ensure the cabinet isolating switch located inside the refrigeration unit compartment is turned on Refrigeration The refrigeration unit evaporator and condenser fans should all operate Unit continuously from the time the cabinet is plugged in The internal cabinet air will continue to circulate at all times The compressor will sta
Download Pdf Manuals
Related Search
Related Contents
SUNNE PRO03 project mount カタログ - 株式会社日立情報通信エンジニアリング Electrolux Dito 601156 User's Manual Click Here for PDF - VersaCall Service Page St. Paul SUSD36COM-AU Installation Guide Handbuch A10 und NRG PlugIn Installation Manual - Link Engine Management VGA Splitter User Manual Copyright © All rights reserved.