NXRT Online UPS User & Installation Manual

image

Contents

1. Charger fault Fan fault Batteries discharged to low voltage level Green LED If this LED is illuminated it indicates that everything is normal and the UPS is being powered by incoming AC utility or by the batteries LCD Descriptions There are four lines of information in the LCD display Each line provides specific information related to the unit status and or operation Line information will be described from top to bottom with the top being line one Line One Provides data in to numeric sections with the data corresponding to the applicable category in line one and two Line Two Allows the user to identify which variable information is being displayed Input Output Battery Load Temperature Line Three This is a graphics section with load graphics on the left and battery graphics on the right The failure icon will ap pear in this section when a failure occurs Line Four This indicates the status of the UPS ON LINE utility mode ON BATT battery mode ON BPS bypass mode UPS OFF standby mode Xtreme Power Conversion Corporation Page 12 NXRT User s Manual Uninterruptible Power Supply RS 232 Standard Interface The RS 232 interface uses a 9 pin female D sub connector Information provided includes data about utility load and the UPS The interface port pins and their functions are identified in the following table 00000 CEL PINE FUNCTIONS 14678 NOT USED
2. Denver CO 80223 Attn LPP RMA 3 XPCwill evaluate the Product to determine its level of functionality and will examine the Product for evidence of damage from a Power Disturbance IF XPCs evaluation provides no evidence of damage from a Power Disturbance XPC will send to the Purchaser i report summarizing the tests performed and ii a rejection of claim notice If the Product shows evidence of damage from a Power Disturbance XPC will request that all Con nected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the Connected Equipment has been damaged by a Power Disturbance XPC will in its sole discretion issue payment to the Purchaser for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above XPC reserves the right to require the Purchaser to transfer title and deliver the Connected Equipment to XPC if it chooses to reimburse the Purchaser for the fair market value of the Connected Equipment XPCs maximum liability shall be reduced to reflect all such other payments or sources of recovery whether applied for or not 4 IF XPC issues payment to the Purchaser to have the Connected Equipment repaired the repair must be per formed at a service center that is authorized by the manufacturer of the Connected Equipment XPC rese
3. Xtreme Power Conversion Limited Warranty Xtreme Power Conversion Load Protection Policy Appendix A Extended Battery Pack User Guide Estimated Run Time for UPS with Extended Battery Packs Extended Battery Pack Configuration LeD Description Extended Battery Pack Operation Extended Battery Pack Installation Extended Battery Pack Q amp A Xtreme Power Conversion Corporation Page 3 NXRT User s Manual Uninterruptible Power Supply Thank you for selecting this Uninterruptible Power Supply UPS It provides you with protection for connected equipment Please read this manual before installing the NXRT Series UPS models NXRT 1000 NXRT 1500 NXRT 2000 and NXRT 3000 as it provides important information that should be followed during installation and main tenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and per formance Included is information on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Xtreme Power Conversion Corporation Page 4 NXRT User s Manual Uninterruptible Power Supply EMC Statements FCC Part 15 Notice Pursuant to section 15 of the FCC rules thi
4. 2 TRANSMIT 3 RECEIPT 5 GND 9 REMOTE WAKE UP CAUTION MAX RATED VALUES 12VDC SNMP Communications Option The UPS provides an intelligent slot for internal or external network card This special intelligent network card can be compatible with popular software and hardware found on the web and in operating systems It can support op erating systems such as HP Open View IBM Netview SUN Netmanager etc This enables the UPS to provide instant UPS and power information over the network Please contact your reseller for additional details Notes The UPS can be monitored through the RS232 interface or the SNMP card but only one way at a time The user can choose RS232 or SNMP communications through the communications switch on the rear panel of the UPS S232 is chosen if the switch is depressed to the RS232 position and SNMP is chosen if the switch is depressed to the SNMP position When there two or more monitored pieces of equipment the ground of each piece of equipment should be shared The SNMP card is configured as DHCP by default IP setting Remote Emergency Power Off REPO Port A customer supplied switch located remotely can be used to close the REPO connection and allows the UPS output receptacles to be switched off Since the REPO shuts down the equipment immediately orderly shutdown proce dures are not followed by any power management software The UPS will have to be manually restarted in order to regain power
5. BYP MODE LINE MODE BAT MODE BAT TEST MODE BUS FAULT 62 05 25 01 21 40 41 INV FAULT 61 63 04 24 42 OVERHEAT 33 06 08 43 OP SHORT 16 02 44 OVERLOAD 03 09 45 FAN FAULT 36 28 38 46 CHARGE FAULT 07 07 11 11 Xtreme Power Conversion Corporation Page 30 NXRT User s Manual Uninterruptible Power Supply Specifications MODEL NUMBER INPUT Capacity 1000VA 700W 3000VA 210044 Voltage range 55 136 Frequency 50 auto sensing OUTPUT Voltage 120AC Waveform Pure ss wave zero transfer bine Frequency auto sensing Efficiency 290 Da TEST Tan at pss Overload capacity 110 150 for 30 sec 15076 for 200 ms Crest factor 3i BATTERY Battery type UPS 8112 a 12v 7 48 a 12 7 2AN S6V Prep batiery pac ET EM a Battery y Zx G EV GANTRY x 4 12V 7244745 FEES Typically lt a hours PHYSICAL UPS dimensions WXDXH 173x177x34in 173x256x341 173217482 UPS weight 387 s 57316 uds ee dimensions W x D 173 173925503410 1730217952 weigh 75 0 Ibs 11360 ns card GR STOP CACEN Receptacles 1 NEMA LS 208 8 NEMA 5 208 TI NEMA L5 308 4 NEMA 5 208 ENVIRONMENT Operating temperature 31 10 40 C Audible nos JOdBA Altitude ILSOUT above sea level Vue y IESUS TEE E Tue ene mode
6. Bac mode ERE ALARMS Audible alarm Beep every UPS fault Continuous beeping sound and LCD display APPROVALS UL cUL FCC WARRANTY 3 years electronics and battery 2 years outside of USAT COMMUNICATIONS INTERFACE 85232 EPO Intelligent slot for optional cards Web SNMP Relay dry contact INCLUDED IN BOX UPSILON CD horizontal brackets 5 1 brackets user manual Gt DBS cable AVAILABLE OPTIONS S year extended warranty bypass distribution X8DM power distribution Xtreme Power Conversion Corporation Page 31 NXRT User s Manual Uninterruptible Power Supply Shipping List a ups 1 User s and Installation Manual 1 6 ft RS232 cable 1 UPSILON CD monitoring software 2 sets of 5 in 1 mounting brackets 1 set of horizontal mounting brackets Xtreme Power Conversion Corporation Page 32 NXRT User s Manual Uninterruptible Power Supply Obtaining Service If the UPS requires Service 1 Use the TROUBLESHOOTING section in this manual to eliminate obvious causes 2 Verify there are no circuit breakers tripped 3 Callyourdealerforassistance Ifyoucannotreachyourdealer oriftheycannotresolvethe problem callXtreme Power Conversion Corp Technical Support at 800 582 4524 Technical support inquiries can also be made at support Expec com Please have the following information available BEFORE calling the Technical Support Department Your name and
7. Guide Inspect the UPS upon receipt The packaging is recyclable keep it for reuse or dispose of properly Safety Information Information presented here is vital to all personnel Please read all Safety information Storage and Transportation Please handle the UPS and associated equipment with extreme caution since a high amount of energy is contained in the batteries Always keep the unit in an upright position as marked on the packaging and never drop the unit Please adhere to the following instructions if the UPS is not installed immediately Store the equipment as is in its original packing and shipping carton Do not store in temperatures outside the range of 15 C to 25 C Ensure that the equipment is fully protected from wet or damp areas and from moist air In order to maintain the batteries the UPS should be recharged every 6 months for at least 8 hours If flammable substances such as gases or fumes are present or if the room is airtight a hazardous situation may exist in which no electrical equipment should be operated The instructions in this manual explain how to install the UPS safely Not acknowledging such electrical hazards may be fatal keep this manual for future reference Xtreme Power Conversion Corporation Page 14 NXRT User s Manual It is strongly recommended that the UPS cabinet not be opened as components have very high voltage and touching those components may be fatal Only a qualif
8. Power Conversion Corporation Page 39 NXRT User s Manual Uninterruptible Power Supply CHARGING LED NXRT EBP FRONT PANEL LED Description The Charging LED GREEN indicates that the battery charger in the Extended Battery Pack is charging normally with the AC power cord attached to the Battery pack AC power cord is only used for every third EBP intstalled The Battery Test LED GREEN indicates that the DC output of the Extended Battery Pack EBP is normal To perform the Battery Test Switch the breaker on the rear of the to ON position 4 Press the Battery Test Button on the front panel of the The DC output from the is normal when the Battery Test LED is illuminated Prior to connecting EBP s test each to assure proper operation Extended Battery Pack Operation The NXRT UPS System can be connected to multiple extended battery packs to increase the runtime when con nected to the UPS supporting the load Most UPS Systems are limited to one or two external battery packs because the UPS is responsible for the recharging and does not have the recharge capacity to handle the additional batter les to a full recharge The NXRT UPS System overcomes this limitation by equipping each extended battery pack EBP with its own charger providing the user a way to achieve significantly more battery backup time 1 The DC Cireuit Breaker on the rear of the EBP connects and disconnects the DC bus voltage fro
9. UPS immediately maximum back up time will still not be available so it is recommended to charge the batter ies for a minimum of 6 hours before use Start and configure the UPS mous v On Off Button Function Button Inquiry Button Press and hold the ON OFF button for more than seconds to turn on the UPS The UPS should now start its inspection of the internal functions main synchronization and inverter startup Then power should start to be supplied via the outlets Once turned on the UPS will perform a self test function when the yellow LED turns to green LCD displays on line and means UPS is working in utility mode Configure the local monitoring software if desired Insert the UPSilon 2000 CD included with UPS packaging into the CD ROM of the local computer 4 Select Install program from the Autorun menu and choose for the correct operating system Follow the setup instructions Enter the product key when prompted The software key is found on the CD cover Click finish when prompted The UPSILON icon will appear in the system tray of the desktop near the system clock Double click this icon to enlarge the program window Connect the RS232 cable included in the UPS packaging to the Computer and UPS Communication should start momentarily If it does not click on Settings up on the UPSilon toolbar then select a dif ferent Comport until communication is established C
10. of any warranty expressed or implied concerning Xtreme Power Conversion equipment and the only obligation of XPC Corporation under this warranty shall be the repair or replacement of defective equipment components or parts or at XPC Corporations sole discretion refund of the purchase price or substitution of an equivalent replacement product Xtreme Power Conversion Corporation Page 34 NXRT User s Manual Uninterruptible Power Supply Xtreme Power Conversion Load Protection Policy THIS POLICY IS NOT A WARRANTY REFER TO THE XPC CORPORATION INC LIMITED WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT THE TERMS OF THE XPC LIMITED WARRANTY Definitions 1 Product means a Standard 120 208 or 240 Volt power protection device that is used in the United States and Canada This policy does not include custom manufactured products 2 Power Disturbance means an AC power line transient telephone line or Local Area Network if appli cable spike or surge Connected Equipment properly connected electronic equipment 4 Fair Market Value of damaged Connected Equipment as determined by XPC shall be the lower of a the average price the same or similar items are being sold for on eBay b the price list of Orion Blue Book or if such price list is no longer published a published or announced price list reasonably selected by XPC c
11. operations that users are permitted to do are Turning the UPS unit ON or OFF Operating the user interfaces Connecting data interface cables Changing the batteries All such operations are to be performed exactly as instructed in this manual The greatest care possible must be taken for any of these operations and any change thereof may prove very hazardous to the operator cuv J On Off Button Function Button Inquiry Button Turning Off the UPS when connected to an AC source Press and hold the ON OFF button for more than seconds to turn off the UPS This means the internal inverter has been deactivated The unit will run a self test prior to the deactivation of the inverter The green LED will be off and the yellow LED will be on The LCD display will indicate On BPS which means the UPS in providing no output Starting the UPS from a DC source cold start Assure that the UPS has fully charged batteries and the internal battery pack is connected Assure that there is no AC input power source and or the unit is not plugged into an outlet Press and hold the ON OFF button for three seconds Once turned on the UPS will perform a self test function when the yellow LED turns to green LCD dis plays On Batt the UPS is now functioning in DC mode Turning Off the UPS when in DC Mode Press and hold the ON OFF button for more than 3 seconds to turn off the UPS Th
12. to the outlets on the UPS Xtreme Power Conversion Corporation Page 13 NXRT User s Manual Uninterruptible Power Supply Determining The Power Requirements Of Your Equipment 1 sure the total Volt Amp VA requirements of your connected equipment does not exceed the maxi mum VA rating for the UPS The maximum VA ratings are shown in the Specifications section of this docu ment 2 Ensure that the equipment plugged into the battery powered outlets does not exceed the UPS rated ca pacity If UPS rated capacities are exceeded an overload condition may occur and cause the UPS to shut down and trip the circuit breaker Ifthe power requirements of your equipment are listed in values other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The equation below only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any given time Users should expect usage requirements to be approximately 60 of the value to estimate power requirements VA Watts W x 1 43 VA or__ Amps A x 121 Add the totals for all of the equipment and multiply this total by 0 65 to calculate actual power require ments Note Many factors can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 85 of the UPS capacity Hardware Installation
13. will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit Slide the plastic cover to the right Remover the MSx10 screws on the right side Xtreme Power Conversion Corporation Page 27 NXRT User s Manual Uninterruptible Power Supply m Remove plastic front cover Locate the battery tray on the right front side of the UPS Remove the battery tray from the UPS Xtreme Power Conversion Corporation Page 28 NXRT User s Manual Uninterruptible Power Supply Troubleshooting Issue Audible Alarm Alarm Description What You Should Do The Input letters in the second row of the LCD are flashing Two Beeps per second at startup for 8 total seconds The Input Voltage or frequency may be beyond the normal acceptable range Verify that utility voltage and frequency is within acceptable range If so contact support The Input letters in the second row of the LCD are flashing One beep per 2 minutes Possible mis wiring AC line and neutral line Check wiring of input to UPS reversed wiring etc Rewire if necessary Battery Indicator Flashing One beep per second Batteries are under charged disconnected or need to be replaced Check UPS batteries If necessary reconnect bat teries wait 12 hours to charge or replace defec tive batte
14. 3 184 248 315 NXRT 3000 3000 2100 9 32 60 89 120 152 Note for estimated run times using more than 5 EBP s contact Xtreme Power Conversion at support xpcc com CAUTION It is very critical to connect the correct voltage with the UPS intended EBP1 is for NXRT 1000 EBP2 is for NXRT 1500 EBP3 is for NXRT 2000 3000 CONNECTING THE INCORRECT BATTERY PACK TO THE UPS MAY RESULT IN DAMAGE TO THE UPS AND OR BATTERY PACK WILL VOID THE WARRANTY AII EBP s have a different DC voltage configuration intended only for the UPS s listed above PLEASE DO NOT MIX EBP s AND MAKE SURE YOU ONLY CONNECT THE TO LIKE EBP s OR UPS INDICATED ABOVE DC VOLTAGES ARE MARKED ON BOTH THE UPS AND THE MAKE SURE THEY MATCH CAUTION CHECK VOLTAGE py Paok nest CS CAUTION LABEL ON EBP CABLE CONNECTORS PLEASE CHECK VOLTAGES CAREFULLY Xtreme Power Conversion Corporation Page 38 NXRT User s Manual Uninterruptible Power Supply Extended Battery Pack Configuration euren MM REL EFE o kJ TAS EXTENDED BATTERY PACK 1 EBP1 FOR NXRT 1000 BATTERY BATTERY BREAKER Socker INPUT BREAKER INPUT SOCKET EXTENDED BATTERY PACK 2 EBP2 FOR NXRT 1500 BATTERY BATTERY BREAKER SOCKET FAN INPUT BREAKER INPUT SOCKET EXTENDED BATTERY PACK 3 EBP3 FOR NXRT 2000 3000 Xtreme
15. CE PERSONNEL ONLY CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the bat tery under the supervision of Qualified Service Personnel knowledgeable of batteries and their precautions CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION Although the battery system voltage is only 12VDC and 24VDC the battery can present a high risk of short circuit current and electrical shock The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the battery 1 Remove all watches rings or other metal objects Only use tools with insulated handles Do nat lay tools or metal parts on top of battery or any terminals Wear protective eye wear goggles rubber gloves and boots Disconnect the charging source before connecting or disconnecting the battery terminals Determine if the battery is inadvertently grounded if inadvertently grounded remove the source of the ground Contact with a grounded battery can result in electrical shack The likelihood of such shock
16. Conversion Corporation Page 16 NXRT User s Manual Uninterruptible Power Supply Vertical Installation Steps NXRT 1000 NXRT 1500 NXRT EBP1 NXRT EBP2 Use M4 x 6 screws on places marked with letter A o 9 o 0 NXRT 2000 NXRT 3000 NXRT EBP3 Use M4 x 6 screws on places marked with letter A Xtreme Power Conversion Corporation Page 17 NXRT User s Manual Uninterruptible Power Supply Wall mounted Installation Steps AE 4 eo 9 9 e go 99 B B B NXRT 1000 NXRT 1500 NXRT EBP1 NXRT EBP2 Use 5 12 screws on places marked with letter NXRT 2000 NXRT 3000 NXRT EBP3 Use 5 x 12 screws on places marked with letter Xtreme Power Conversion Corporation Page 18 NXRT User s Manual Uninterruptible Power Supply 19 Rack mount using 5 in 1 bracket NXRT 1000 NXRT 1500 NXRT EBP1 NXRT EBP2 Use M5 x 12 screws on places marked with letter EE x To 5 c 5 o o 5 9 s 3 9 5 B B o o NXRT 2000 NXRT 3000 NXRT EBP3 Use 5 12 screws on places marked with letter Xtreme Power Conversion Corporation Page 19 NXRT User s Manual Uninterruptible Power Supply Rack Mount Installation Steps UPS Rail Installation Instructions to 19 Cabinet Step 1 20 EAR FOR
17. Corporation Page 33 NXRT User s Manual Uninterruptible Power Supply Xtreme Power Conversion Limited Warranty Xtreme Power Conversion XPC Corporation warrants Xtreme Power Conversion equipment when properly ap plied and operated within specified conditions against faulty materials or workmanship for a period of three years for NXRT Series products from the date of purchase XPC Corporation warrants internal batteries for a period of three years from the date of purchase For equipment sites within the United States and Canada this warranty covers repair or replacement at the sole discretion of XPC Corporation The customer is responsible for the costs of shipping the defective product to XPC Corporation XPC Corporation will pay for ground shipment of the re paired or replacement product This warranty applies only to the original purchaser If equipment provided by XPC Corporation is found to be Dead on Arrival DOA XPC Corporation will be respon sible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer once the customer has requested and received a Return Material Authorization RMA number DOA equipment is defined as equipment that does not properly function according to user documenta tion when initially received and connected in conjunction with proper procedures as shown in the user documen tation or via support provided by XPC Corporation personnel or au
18. IATED EQUIPMENT LOSS OF SOFTWARE COST OF CAPITAL COST OF ANY SUBSTITUTE EQUIPMENT FACILITIES OR SERVICES DOWNTIME THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS AND INJURY TO PROPERTY Submitting a Load Protection Policy Claim 1 Any claim under the Load Protection Policy must be made within 10 days of the date of alleged damage to the Connected Equipment 2 Call the XPC technical support department at 1 800 582 4524 and obtain a Load Protection Policy Returned Material Authorization RMA number Have information on all applicable insurance or other resources of re covery payment that is available to the Purchaser and the name of the power utility supplier for the location of the Connected Equipment XPC will forward to the Purchaser a Load Protection Policy claims form which Xtreme Power Conversion Corporation Page 36 NXRT User s Manual Uninterruptible Power Supply must be completed and filed with XPC within 30 days Mark the Load Protection Policy RMA number on the Product the Purchaser is returning Pack the Product in its original packaging or similar packing materials if the original packaging has been discarded Enclose the completed Load Protection Policy claim form and a copy of the Purchas er s original sales receipt for the Product in the box Mark the RMA number clearly on the outside of the box Ship the Product one way shipping charges paid by the Purchaser to XPC Corporation 230 Yuma Street
19. K THAT WILL VOID THE WARRANTY Ensure that the UPS is disconnected from AC input and is off while connecting the External Battery Packs Ensure all battery breakers are in the OFF position Remove the covers on the UPS and Connect the battery cable that comes with the External Battery Pack between the External Battery Pack to the UPS 4 Secure the DC battery cable to the rear of the UPS and the rear of the by using M3 x 8 screws provided 2 each per connector end Connect the 5 15 from the to an input AC utility source per specifications Connecta second battery pack to the first in the same fashion if more than one is to be installed Refer to Appendix A Battery Pack User Manual for more details Connect SNMP card option Remove the two screws securing the SNMP cover plate on the rear of the UPS and slide the SNMP NetAgentll card into the slot Secure the card into the slot with the two screws previously removed Close the battery breakers on the Optional battery packs if installed Connect the AC input cable to the UPS and connect the other end to an approved grounded outlet Once the UPS has been connected to an AC power source the internal charger will start charging the UPS bat teries at this point the yellow LED is illuminated and the LCD displays UPS OFF In this state the output voltage is zero which means UPS has no output Please realize that although you may start using the
20. NXRT Online UPS 1000VA 1500VA 2000VA 3000VA Models User amp Installation Manual www xpec com 2014 Xtreme Power Conversion Corporation All rights reserved Rev 8 13 14 NXRT User s Manual Uninterruptible Power Supply Table of Contents EMC Statements FCC Part 15 ICES 003 Declaration of Conformity Request Special Symbols Introduction ProductDescription Double Conversion Online Technology Diagnostic Tests System Configuration LEDDescription LCD Descriptions RS 232 Standard Interface SNMP Communications Optio Remote Emergency Power Off REPO Port Determining The Power Requirements Of Your Equipment Hardware Installation Guid Safety Information Storage and Transportation Environment Installation Rack Mount Installation Steps UPS Rail Installation Instructions to 19 Cabinet User s Operations Turning Off the Ups When Connected to an AC Source Starting the UPS From a DC Source Cold Start Turning Off the UPS When in DC Mode Self Test Operation Audible Alarm Silence in DC Mode or Fault Mode Xtreme Power Conversion Corporation Page 2 NXRT User s Manual Uninterruptible Power Supply Batteries Replacing The Battery Troubleshooting LCD Fault Codes Specifications Shipping List Obtaining Service
21. RC QP P Xtreme Power Conversion Corporation Page 7 NXRT User s Manual Uninterruptible Power Supply Introduction The information provided in this manual covers single phase 1000 3000 VA uninterruptible power systems their basic functions operating procedures options available and emergency situations It also includes information on how to ship store handle and install the equipment Only detailed requirements of the UPS units are described herein and installation must be carried out in accordance with this manual Electrical installation must also care fully follow local legislation and regulations Only qualified personnel should conduct these installations as failure to acknowledge electrical hazards could prove to be fatal Product Description Many different kinds of sensitive electrical equipment can be protected by an Uninterruptible Power Supply UPS including computers workstations process control systems telecommunications systems sales terminals other critical instrumentation etc The purpose of the UPS is to protect these systems from poor quality utility power complete loss of power or other associated problems Electrical interference exists in many forms causing problems in AC power from lightning power company ac cidents and radio transmission motors air conditioners and vending machines Protection of sensitive electrical equipment is vital to protect against power outages low or high voltage conditi
22. SOCKET BREAKER SOCKET INTERFACE NXRT 1000 REAR VIEW inpur INTERNAL COMMUNICATION BREAKER snap stot REPO SWITCH OUTPUT BATTERY AC INPUT FAN SOCKET SOCKET NXRT 1500 REAR VIEW Xtreme Power Conversion Corporation Page 10 NXRT User s Manual Uninterruptible Power Supply outeur INTERNAL COMUNICAT LN Sacret di INTERFADE COMMUNICATION OUTPUT HIGH CURRENT INPUT ACINPUT BATIERY SwiToH BREAKER OUTPUT SOCKET BREAKER SOCKET NXRT 2000 REAR VIEW Qureur INTERNAL COMUNICAT ion SOCKET SMP SLOT INTERFACE COMMUNICATION OUTPUT MIGH QURRENT INPUT INPUT BATTERY BREAKER OUTPUT SOCKET BREAKER socket NXRT 3000 REAR VIEW NXRT FRONT CONTROL PANEL Xtreme Power Conversion Corporation Page 11 NXRT User s Manual Uninterruptible Power Supply LED Description The UPS has three LED s on the front control panel These LED s allow the user to quickly understand if any action is needed Red LED If this LED is illuminated it indicates a fault and the UPS will have no output Faults that would indicate this alarm condition include Overload Inverter fault BUS fault Over temperature fault Yellow LED If this LED is illuminated it indicates the user needs to take some action and included UPS in Bypass Mode Batteries Overcharged
23. UPS Secure the DC battery cable to both the rear of the UPS and the rear of the EBP by using M3 x 8 screws provided 2 each per connector end Repeat the above procedure for testing and securing each additional required CAUTION Do not use extension cords when connecting input AC power to UPS or EBP s only connect every third Move the DC circuit breaker on the rear of each to the ON position At this point the UPS will need to be started If the EBP s are plugged into an AC source and properly installed the internal batteries will be charged when acceptable voltage is present EBP s must be charged for a minimum of 6 hours for full battery time Xtreme Power Conversion Corporation Page 42 NXRT User s Manual Uninterruptible Power Supply NOTE If the EBP is going to be out of service or stored for six months or longer the batteries must be re charged for at least 36 hours every six months Extended Battery Pack Q amp A 1 Which do I connect to an AC input source Itis recommended that every third be connected to incoming AC utility to properly charge the bat teries in a complete system Leaving too many chargers connected may cause an over charge situation which could damage the batteries and void the warranty 2 Which LED s are supposed to be lit on the front of each 4 When an is connected to an AC input source and the unit is charging a GREEN LED on the front of
24. UPS OR MOUNING IN CABINET EXPANDABLE RAIL FOR UPS OR EBP MOUNTING IN CABINET Step 3 MOVEABLE NUT FOR MOUNTING RAIL KIT IN Xtreme Power Conversion Corporation Page 20 NXRT User s Manual Uninterruptible Power Supply Step 4 UPS FRONT VIEW AFTER INSTALLING 2U EARS Step 5 ASSEMBLE THE RAIL ONTO THE CABINET U BAR WITH SCREWS AT FRONT amp BACK USING MOVABLE NUTS Step 6 PUSH THE UPS OR INTO THE CABINET VIA THE RAIL FROM THE FRONT Xtreme Power Conversion Corporation Page 21 NXRT User s Manual Uninterruptible Power Supply Step7 ATTACH UPS OR EBP EAR ONTO CABINET U BAR WITH SCREWS ON BOTH LEFT amp RIGHT SIDES Note Any external Battery Packs must be installed next to or under the UPS Please refer to Appendix A Battery Pack User Guide for more information when installing these Xtreme Power Conversion Corporation Page 22 NXRT User s Manual Uninterruptible Power Supply INITIAL CONNECTION AND STARTUP Ensure that the UPS and optional battery packs are mounted correctly and the UPS is disconnected from input power before proceeding 1 Connect external battery packs option CAUTION CONNECT ONLY BATTERY PACKS PROVIDING THE SAME DC VOLTAGE AS THE UPS PLEASE DOUBLE CHECK LABELING ON THE UPS AND BATTERY PACKS TO ASSURE PROPER VOLTAGES ARE CON NECTED CONNECTING THE INCORECT BATTERY PACK TO THE UPS MAY RESULT IN DAMAGE TO THE UPS AND OR BATTERY PAC
25. Units labeled with a UL mark comply with the following standards and directives UL1778 CAUTION A shielded type power cord is required in order to meet FCC emission limits and to prevent interference to the nearby radio or TV reception It is essential that only the supplied power cord be used Use only shielded cables to connect I O devices to this equipment WARNING Any changes or modifications not expressly approved by the manufacturer of this device could void the user s authority to operate the equipment IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS CAUTION UPS having Internal Batteries Risk of electrical shock Hazardous live parts inside this unit are ener gized from the battery supply even when the input AC power is disconnected CAUTION No User serviceable Parts Risk of electrical shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input haz ardous voltage may exist between battery terminals and ground Test before touching Fuses To reduce the risk of fire replace only with the same type and size of fuse WARNING Unit intended for installation in a controlled environment CAUTION Do not dispose of batteries in a fire the battery may explode Xtreme Power Conversion Corporation Page 5 NXRT User s Manual Uninterruptible Power Sup
26. XRT User s Manual Uninterruptible Power Supply Diagnostic Tests When the UPS is started a diagnostic test is automatically executed checking the electronics and batteries report ing any problems on the LCD display A diagnostic test can also be performed manually from the front panel at any time Xtreme Power Conversion Corporation Page 9 NXRT User s Manual Uninterruptible Power Supply System Configuration The UPS device and the internal batteries make up the system Depending on the site and load requirements of the installation certain additional options are available for the solution Planning a UPS system the following should be taken into consideration The total demand of the protected system shall dictate the output power rating VA Allow a margin for future expansion or calculation inaccuracies from measured power requirements Backup time required will indicate the battery size needed If the load is less than the UPS nominal power rating then actual backup time is longer The following options are available Extended Battery Packs NXRT EBP1 for 1000 NXRT EBP2 for 1500 4 NXRT EBP3 for 2000 3000 Connectivity Options SNMP WEB card o Xtreme Power Distribution Units XPDU See the Specification section of this manual for additional model information a b El m ourpur IMPUT COMMUNICATION
27. address The serial number of the unit Where and when the unit was purchased Allof the model information about your UPS Any information on the failure including LED s that may or may not be illuminated A description of the protected equipment including model numbers if possible A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available as the Technical Sup port Technician about obtaining a replacement set of packaging material It is important to pack the UPS properly in order to avoid damage in transit Never use Styrofoam beads for a packing material 2 Include a letter with your name address daytime phone number RMA number a copy of your original sales receipt and a brief description of the problem 3 Mark the RMA number on the outside of all packages Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes 4 Return the UPS by insured prepaid carrier to the address provided by the Technician 5 Refer to the Warranty statements in this manual for additional detalls on what is covered Xtreme Power Conversion
28. ied technician or authorized agent may service the unit Uninterruptible Power Supply The UPS unit s output receptacles carry live voltage even when not connected to an input voltage source The UPS has its own internal energy source Environment Ensure that all environmental concerns and requirements are met according to specifications listed in this document otherwise the safety of installation personnel cannot be guaranteed and the unit may malfunction Ensure that you remember the following when locating the UPS system and battery options Avoid extremes of temperature and humidity Maximum battery life can be attained with a recommended temperature range of 15 to 25 C Provide protection for the equipment from moisture Space and ventilation requirements must be met Ensure there is 100mm behind and SOmm on the sides of the UPS for proper ventilation Ensure that the front of the UPS remains clear for user operation Installation Standard brackets 3U 5 IN 1 BRACKET FOR NXRT 1000 NXRT 1500 2000 NXRT 3000 1 amp EBP2 amp EBP3 Xtreme Power Conversion Corporation Page 15 NXRT User s Manual Uninterruptible Power Supply 19 Cabinet Ear Installation NXRT 1000 NXRT 1500 NXRT EBP1 NXRT EBP2 Use M4 x 6 screws on places marked with letter A NXRT 2000 NXRT 3000 NXRT EBP3 Use M4 x 6 screws on places marked with letter A Xtreme Power
29. is means the internal inverter has been deactivated During the shutdown period the UPS will run a self test Once the self test has been completed assuming there is still no AC input the LCD will no longer display information This indicates the UPS has no output Self Test Operation Please refer to the three operating buttons on the front panel of the UPS Confirm the UPS is in Utility Mode Press and hold the Function button for a minimum of two seconds The self test will last for 10 seconds during this time the LED s will be lit in a sequential repeating fashion Xtreme Power Conversion Corporation Page 25 NXRT User s Manual Uninterruptible Power Supply Audible Alarm silence in DC Mode or Fault Mode When the UPS is in DC Mode the audible alarm will sound every four 4 seconds Press and hold the Function Button for a minimum of two 2 seconds to disable the audible alarm When the UPS is in Fault Mode the audible alarm will continuously sound Press and hold the Function Button for a minimum of two 2 seconds to disable the audible alarm Xtreme Power Conversion Corporation Page 26 NXRT User s Manual Uninterruptible Power Supply Batteries The life of batteries used in these UPS products is estimated at 3 6 years depending on level of usage Once the battery is no longer useful and must be replaced please contact service personnel for assistance Replacing The Battery QUALIFIED SERVI
30. lick on Manual in the UPSILON toolbar for further software configuration NOTE PLEASE VERIFY AUTOMATIC SHUTDOWN TIME PARAMETERS IN THE SETTINGS SECTION FOR Xtreme Power Conversion Corporation Page 23 NXRT User s Manual Uninterruptible Power Supply YOUR SPECIFIC INSTALLATION Configure the optional NetAgentll SNMP card if installed Insert the NetAgent Utility CD included with SNMP packaging into a PC and download the user man ual Install Netility from the AutoRun menu Connect a network cable from the PC to the SNMP card Run Netility program and it will auto search and list available NetAgents SNMP card Highlight and click Configure to change the network settings on the NetAgent discovered Disconnect the cable to the PC and connect the SNMP card to your network Access the SNMP card via the network and make configuration changes using the manual downloaded previously 4 NOTE PLEASE VERIFY AUTOMATIC SHUTDOWN TIME PARAMETERS IN THE SETTINGS SECTION FOR YOUR SPECIFIC INSTALLATION fter charging is complete connect the loads to the UPS while monitoring the load levels via the UPS LCD or via the software Do not connect any devices that have the possibility of overloading the UPS Refer to the Troubleshooting section and or Technical Support with any problems during setup Xtreme Power Conversion Corporation Page 24 NXRT User s Manual Uninterruptible Power Supply User s Operations The only
31. llation must comply with all applicable electrical and safety codes set forth pursuant to the NEC 4 The Product must have undeniable physical evidence of a Power Disturbance that directly and proximately caused the damage 5 The Connected Equipment must have been damaged by a Power Disturbance on a properly installed grounded and National Electric Code NEC code compliant 120 208 240 Volt AC power line in the United States or Canada by a Power Disturbance on standard telephone land line or PBX telephone equip ment line that is properly installed and connected to an 11 port on the Product or by a Power Distur bance on a standard Local Area Network connection that is properly installed and connected to an R 4S port on the Product and d is directly plugged into and properly connected to the Product in its original condition which was properly operated when a Power Disturbance passed through the Product and i exhausts the protection capacity of the Product or ii damages the Product 6 The Load Protection Policy does not apply if the Product has been operated in a failure mode or not in compliance with XPC operating instructions in the Product user s manual or if the Connected Equipment has not been operated in compliance with the instructions and manuals of its manufacturer vendor 7 This policy is null and void if XPC determines in its sole discretion that the Product has been tampered with or altered in any way What is No
32. m the EBP to the UPS The DC Circuit Breaker will also trip to the OFF position in the event of an over current condi tion in the EBP Xtreme Power Conversion Corporation Page 40 NXRT User s Manual Uninterruptible Power Supply EBP2 rear view 2 The 5 use a cable shipped with each to daisy chain together additional EBP s to the first be ing connected to the UPS in the appropriately labeled connector or for connecting the first EBP to the UPS urs 7 Esp 4773 7 773 7 7 EBP T daisy chain to UPS or other 3 The AC input cord is for connecting AC utility to operate the Charger contained in every third Xtreme Power Conversion Corporation Page 41 NXRT User s Manual Uninterruptible Power Supply 4 EBP s daisy chain to UPS or other The input AC Circuit Breaker will trip to the OFF position in the event that the internal charger draws excessive current Extended Battery Pack Installation CAUTION Extended Battery Pack EBP Installation should be performed by qualified service personnel rm Verify that the DC circuit breaker on the rear panel of the EBP is in the OFF position Turn the UPS OFF and disconnect the UPS Input Cord from the AC wall outlet Remove the connector cover from the UPS rear panel Connect the external DC battery cable from the EBP to the appropriate connectar on the
33. ons slow voltage fluctuations frequency variations differential and common mode noise transients etc To prevent power line problems from reaching critical systems causing damage to software hardware and equip ment malfunctions the UPS maintains constant voltage isolating critical load output and cleaning the utility AC power Double Conversion Online Technology A double conversion on line technology UPS provides completely isolated clean uninterrupted single phase pow er to your critical systems while maintaining the batteries for their maximum potential In the event that the power failure lasts longer than the UPS backup time the UPS will shut down avoiding battery damage When the input AC voltage returns the UPS will automatically return online to recharge the batteries As shown in block diagram An input filter reduces transients on the incoming utility To maintain full battery charge the AC input power is rectified and regulated in the rectifier feeding power to the battery converter and inverter DC power is converted to AC in the inverter passing it on to the load Power is maintained from the battery during a power failure The converter increases voltage appropriately for the inverter Rectifier Inverter Monitoring panel Control H Rs232 Monitoring 1 1 Slot Xtreme Power Conversion Corporation Page 8 Charger battery switch Hd N
34. perature and humidity control in order to reduce the risk of electric shock Itis best to disconnect the device using the power supply cord Ensure that the equipment is placed in a position near the outlet where easily accessible Except for replacing the batteries all servicing on this equipment must be carried out by qualified service personnel Before conducting any maintenance repair or shipment first ensure that everything is turned off completely and disconnected For additional safety instructions please use the Safety Manual as a reference Xtreme Power Conversion Corporation Page 6 NXRT User s Manual Uninterruptible Power Supply Special Symbols The following symbols used on the UPS warn you of precautions RISK OF ELECTRIC SHOCK Please observe the warning that a risk of electric shock is present CAUTION REFER TO OPERATOR S MANUAL Refer to the operator s manual for additional information such as important operating and maintenance instructions SAFE GROUNDING TERMINAL Indicates primary safe ground LOAD ON OFF Pressing the button turns on off the output receptacles and the indicator light RIAS RECEPTACLE The receptacle provides network interface connections and telephone or telecommu nications equipment should not be plugged into it Please do not discard of the UPS or the UPS batteries as the UPS may have valve regulated lead acid bat teries Please recycle batteries appropriately
35. ply CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To reduce the risk of electric shock disconnect the UPS from the main supply before installing a computer inter face signal cable Reconnect the power cord only after signaling interconnections have been made Servicing of batteries should be performed or supervised by personnel with knowledge of batteries and the re quired precautions Keep unauthorized personnel away from batteries These UPS units are extremely heavy Do not install the UPS in a rack or enclosure by its front two ears only Adjust able rack rails are required for this type of installation The instructions contained within this safety manual are deemed important and should be closely followed at all times during installation and follow up maintenance of the UPS and batteries Saumon The unit has a dangerous amount of voltage If the UPS indicator is on the unit s outlets may have a dangerous amount of voltage even when not plugged into the wall outlet because the battery may continue to supply power Care should be taken to undertake installation indoors free from electrically conductive particles Which are under tem
36. ries Utility Normal UPS has AC input N A Possibility that circuit breaker on UPS has tripped Reset circuit breaker Insufficient battery run time Once every 4 seconds in DC mode On batt displayed on 10 If batteries are un dercharged let UPS charge batteries at least 12 hours After charging if runtime is still insuf ficient replace with new batteries Reduce output load to lengthen runtime UPS will not start after pressing the On Off button N A Insufficient time for button depression UPS has no battery connected Battery voltage is too low to power the load Fault has occurred inside the UPS Depress the On Off button for at least three seconds Make sure the batter ies are connected and the connector on the battery cartridge is mated correctly Plug the UPS in remove all loads and allow to charge for 12 hours 4 Contact dealer for service details Major fault detection by the UPS Constant beep Type of fault and fault code displayed on LCD Review abnormal process information table listed below in this manual and take appropriate action If problem does not resolve contact supplier for service and provide error code s Xtreme Power Conversion Corporation Page 29 NXRT User s Manual Uninterruptible Power Supply LCD Fault Codes
37. rranty P90 P9OL 906 PSOLg 50200 Term of XPC Limited Warranty T30 50 000 Term of XPC Limited Warranty TX90 TX90i 50200 Term of XPC Limited Warranty This Load Protection Policy is not deemed first dollar coverage XPC s obligation is reduced by any amounts that the Purchaser is entitled to recover from other sources regarding the Connected Equipment including but not limited to insurance other warranty extended warranty or legal liability regardless of whether or not the Pur chaser makes a claim for recovery Eligibility for Coverage Under the Load Protection Policy 1 The Product must be registered on the XPC website www xpcc com within 10 days of purchase All re quired information must be provided and Purchaser should retain a copy for Purchaser s records When registering on the website Purchaser must list all connected equipment that is directly connected to the Xtreme Power Conversion Corporation Page 35 NXRT User s Manual Uninterruptible Power Supply product Only those devices registered in that manner will be covered 2 All Connected Equipment must be UL or CSA approved 3 The Product must be plugged into a properly wired and grounded outlet Use of input surge devices ex tension cords adapters ground wires or electrical connections not manufactured by XPC voids the XPC Load Protection Policy No other surge protection device may be connected to the output sockets of the Product The insta
38. rves the right to contact the authorized service center directly to discuss repair costs and damage to the Connected Equipment to determine if it was caused by a Power Disturbance and the right to request that the service center forward the Connected Equipment or components of the Connected Equipment to XPC for inspection 5 Unless modified in writing signed by an officer of XPC and the Purchaser the terms of this policy are the com plete and exclusive agreement between the parties superseding all prior agreements oral or written and all other communications between the parties relating to the subject matter of this agreement No employee of XPC or any other party is authorized to make any representations beyond those made in this agreement con cerning the Load Protection Policy XPC Corporation 230 Yuma Street Denver CO 80223 1 800 582 4524 Xtreme Power Conversion Corporation Page 37 NXRT User s Manual Uninterruptible Power Supply Appendix A Extended Battery Pack User Guide Estimated Run Time for UPS with Extended Battery Packs LOAD RUNTIME FOR QTY OF EXTENDED BATTERY PACKS IN MIN va wams ues 1 2 4 EBP 5 500 350 3 91 176 271 374 485 NXRT 1000 1000 700 10 80 123 170 220 750 525 18 68 124 184 248 315 NXRT 1500 1500 1050 9 32 60 90 120 152 1000 700 29 109 200 298 402 510 NXRT 2000 2000 1400 14 52 97 144 194 247 1500 1050 18 67 12
39. s product has been tested and thereby complies to the condi tions of a Class B NXRT 1000 NXRT 1500 and Class A NXRT 2000 NXRT 3000 digital device which have been established for offering sufficient protection against dangerous interference for installation in a residential area Installation and use of the equipment should comply with the instructions provided in order to avoid such interfer ence due to the amount of radio frequency energy that is radiated and generated by the equipment In spite of this we cannot assure that a certain amount of interference may not occur in some installations If by turning on and off it can be deduced that your radio or television reception is found to be influenced by harmful interference from the equipment it is recommended to use one of the following preventive measures Place the receiving antenna in a separate location or orientation Ensure a greater distance is achieved between the receiver and the equipment Ensure that your equipment is connected to an outlet on a separate circuit than the receiver Contacta technician experienced with radio and TV or a dealer for further assistance ICES 003 This Class B Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equip ment Regulations ICES 003 Cet appareil numerique de la classe B respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada Declaration of Conformity Request
40. t Covered Under the Load Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except for damage due to telephone line Local Area Network or CATV transients which is covered only if the Product offers such protection DAMAGE CAUSED BY FAILURE TO PROVIDE A SUITABLE INSTALLATION ENVIRONMENT FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO LACK OF A PROPER SAFETY GROUND Damage caused by the use of the Product for purposes other than those for which it was designed Damage caused by accidents or natural disasters including but not limited to fire flood and wind Damage caused by abuse misuse alteration modification or negligence Any labor costs or travel room and board expenses associated with the repair and or restoration of lost or damaged hardware software or data EXCEPT AS EXPRESSIY PROVIDED IN THIS POLICY XPC SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DIRECT INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL OR MULTIPLE DAMAGES ARISING OUT OF THE USE OF THE PRODUCT OR DAMAGE TO THE CONNECTED EQUIPMENT REGARD LESS OF THE LEGAL THEORY ON WHICH SUCH CLAIM IS BASED EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE SUCH DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF PROFITS LOSS OF SAVINGS OR REV ENUE LOSS OF USE OF THE PRODUCT OR THE CONNECTED EQUIPMENT OR ANY ASSOC
41. the will be illuminated 3 Are any LED s on the front of the EBP supposed to be lit if it is not connected to an AC input source No The UPS and or the EBP s that are plugged into an AC input source are responsible for charging the entire system The is still working and has the capability of providing DC voltage when needed No LED on the front bezel will be illuminated 4 The is connected to an AC input source why does the LED on the front of the turn ON and OFF intermittently and does this mean this is not working The GREEN LED on the front of each indicates that the charger contained in the EBP is charging Under certain conditions when the batteries are 100 charged the charger in the will shut off and the LED will no longer be illuminated This is normal operation for the EBP The EBP is working properly 5 Why don t the LED s on each connected to an AC input source turn ON and OFF at the same time lt charger on each functions independently from the others One charger may be charging while another one might be at 100 and the charger turned off This is normal operation of the EBP Xtreme Power Conversion Corporation Page 43
42. the lowest price the same or similar items can be purchased for in the United States or d the total amount of all payment s you have or are entitled to receive from insurance other warranties extended warranties a legal liability claim or from other sources or persons for the damaged Connected Equipment 5 Purchaser means the person or entity that originally purchased the Product from an authorized reseller or distributor of XPC Products The Purchaser of this Product is protected for the term of the XPC Limited Warranty against certain losses caused bya Power Disturbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions provided below This policy applies only to the original purchaser of the Product If the Product is transferred or sold to another person or entity this policy is void Load Protection Policy Dollar and Period Limits For purchasers that meet the qualifications and conditions set forth in this policy XPC will provide reimbursement cost of repair or fair market value as determined by XPC during the period limits and up to the dollar limits stated as follows PRODUCT DOLLAR LIMIT PERIOD OF COVERAGE 25 000 Term of XPC Limited Warranty XST 25 000 Term of XPC Limited Warranty 570 25 000 Term of XPC Limited Warranty XPRT GkVA amp 10kVA 50200 Term of XPC Limited Warranty NXRT 50 000 Term of XPC Limited Wa
43. thorized agents This warranty shall be void if the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished by XPC Corporation or a XPC Corpora tion authorized representative before or after delivery with regard to the use or application of Xtreme Power Con version equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances but it is used at the recipient s sole risk EXCEPT AS STATED ABOVE XPC Corporation DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT AS STATED ABOVE IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT INDIRECT SPECIAL INCI DENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT including but not limited to any costs lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data cost of substitutes or claims by third parties Purchaser s sole and exclusive remedy for breach