Home

CA-64 KLCD-L

image

Contents

1. identification function must be performed after setting the keypad addresses Setting the same address in several keypads will trigger the anti tampering alarm and also will display the Keypad replaced message and disable operation of such keypads To restore the operation of keypads change their repeating addresses into unique ones The changes can be made as described herein TECHNICAL DATA S pply voltage epee ae RE mre A A Tye ene ee ee Pree ee ee eee 11 14V MIPIMUNT CUITEMt GONSUMPUOM cccccccttterieriec tisha tticteieldiere ttc e tele acca techecrteerkenitaus 60mA Maximum current CONSUMPTION ceeeeeeee cece eect eee eeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeneeea 125mA SATEL 3 CA 64 KLCD L ARMED steady light all partitions operated by the LCD DISPLAY ALARM l 1 do 6 press and hold for 3 sec date and time steady light alarm in to get access to viewing functions partition status operated partition 1 zone status viewing blinking light alarm memory 2 keypad tampers viewing for the partition 3 expander tampers viewing 4 partition armed status viewing 5 alarm memory viewing 6 trouble memory viewing alarm ALARM CONTROL PANEL CA 64 LCD Satel see descriptions of TESTS la Now 13426 24 1 keypad are armed blinking light some partitions are armed 1 32 zones 1 32 or the first expander bus 33 64 zones 33 64 or the second expand
2. Narre CA 64 KLCD L CE ca64kicd_ _e 10 03 The CA 64 KLCD L keypad is designed to interface with the CA 64 alarm control panels DESCRIPTION alarm ALARM CONTROL PANEL CA 64 LCD Satel 14 Novy 3326 24 132 33 64 trouble Figure 1 CA 64 KLCD L keypad The keypad features visual and audible signaling as well as the way of operating the alarm system by means of this keypad correspond to the description contained in the CA 64 Alarm Control Panel User Manual The letters provided on numerical keys may facilitate memorization of the access code by mentally associating it with a particular word e g the code 7 8 2 7 8 corresponds to the word START Special symbols make easier associating particular keys with the alarms which can be activated by using the keys fire auxiliary US panic KEYPAD CONNECTION DESCRIPTION OF TERMINALS KEYPAD PANEL Z1 for detector Additional Z2 for detector System inputs ady WLA WYO WO9 anti tampering contact buzzer Figure 2 LCD L V1 2 keypad board The keypad connection to the main board and the use of the RS 232 port and the Z1 Z2 inputs are described in the manual CA 64 Alarm Control Panel System Description and Installation The CA 64 KLCD L keypad address is saved in the EEPROM non volatile memory It can be programmed in two ways 1 Directly skipping the control panel servi
3. ce code e Turn off the keypad power supply and the data bus wires CKM DTM e Short the keypad terminals CKM and DTM Turn on the keypad power supply The following text will be displayed ALARM CONTROL PANEL CA 64 LcD Satel LCD kpd Address Oe n 0 7 current address of the keypad service __ 1 32 33 64 trouble armed Figure 3 Programming the keypad address e Enter a new address within the 0 7 range The keypad will confirm performance of the function with four short and one long beeps The address can be changed again on pressing the key e Connect the keypad to the control panel as required CKM DTM SATEL 2 CA 64 KLCD L 2 By using the control panel service function e Activate the panel service mode from any supported keypad SERVICE CODE gt Service mode e Select in turn the items from the menu of displayed functions gt Structure gt Equipment gt ldentification gt Keypad addresses On the displays of manipulators which have no physical jumpers a message will appear as shown in Figure 3 corresponding to the language version of control panel program e Enter the appropriate address from the 0 7 range the keypad will confirm performance of the function with four short and one long beeps then press the key the keypad will quit the address change function NOTES For the LCD keypads to be properly supported by the CA 64 control panel the keypad
4. er bus and EVENT HISTORY viewing TROUBLE indicates detection of a technical problem in the system N SERVICE blinking when service mode is active service 1 32 33 64 t m trouble armed to check press and hold key 7 for 3 seconds lt P press and hold for 3 sec to scroll names of partitions where alarm has occurred press briefly to view names of partitions shown on display abc 2 def 3 pe AY press and hold for 3 sec to scroll through names of zones which A triggered an alarm LV ghi 4 jk mno 6 D pars 7 tuv 8 wxyz 9 9 press and hold for 3 sec to change partition status display mode selected all ana pas 7 z oa C 7 press and hold for 3 sec to display a message on currently detected trouble press and hold for 3 seconds press and hold for 3 seconds to to activate PANIC ALARM activate FIRE ALARM 8 press and hold for 3 sec to switch gong signaling in keypad 0 press and hold for 3 CODE call user function menu on off seconds to activate auxiliary ALARM 0 arming CODE arming disarming Figure 4 The description of functions of LCD keypad s indicators and buttons for CA 64 control panel with the 1 04 00 firmware version

Download Pdf Manuals

image

Related Search

Related Contents

3URIHVVLRQDO HTXDOL]HU [ EDQG  FOUR BURNER GAS GRILL - Sure Heat Manufacturing  Le pôle enfance Développement durable Sécurité routière  RT308R 取扱説明書    Operating Instructions DUSTCONTROL Dust Extractor for Folding  SBS TESCREENIP655A2 screen protector  QR Marks the Spot@MDH User Manual    Fujitsu PRIMERGY RX100 S3  

Copyright © All rights reserved.
Failed to retrieve file