1. V vi vii viii xi xii xiii XIV Remove the existing mattress from the bed frame Replace the standard mattress with mattress replacement system orient mattress so that the air tube is at the foot of the bed Secure straps beneath the mattress to the bed frame Hang the control unit on the foot board of the bed frame Attach the air tube connectors to the socket on the left panel of the control unit connectors and sockets are colour coded Verify that air hoses are not kinked under the mattress Attach cover to mattress Plug in the control unit and turn on the master power switch on the right side panel the STANDBY LED will illuminate Push the STANDBY OPERATE button on the front panel OPERATE LED will now be illuminated and the control unit will be in operation Push the AUTO FIRM button for fast inflation Allow 4 7 min for full inflation After the mattress is fully inflated the caregiver can transfer the patient to the mattress note the mattress can be inflated while a patient is laying on it Push AUTO FIRM again to release the fast inflation mode Alternation time can be adjusted by the CYCLE TIME button When the control unit is powered on it will default to previous setting Static Function Push the STATIC button and adjust the comfort control by pressing the SOFT FIRM button to achieve maximum patient comfort On this mode the system provides low air loss therapy Perform a hand check by placing hand under the
2. patient s buttocks between the cells and foam The patient should have at least 4 cm of clearance between the buttocks and the bottom of the mattress If the STATIC function is selected the time display will remain blank Dynamic Function Push the alternate button to enable the 3 1 alternating function Lock out Function When lock out function activates buttons on control panel will be non functional CPR Deflation For quick mattress deflation disconnect the hose connector from the controller and release the CPR quick deflation valve User Manual DynaLAL ahead of the curve 3 Cleaning The mattress should be cleaned on the bed weekly using a damp soft cloth and mild detergent If the top or bottom cover becomes severely soiled remove clean as follows and replace with a clean cover Covers can be washed and thermally disinfected in a washing machine Cover should not be put into a dryer Never use phenol based cleaning solutions Industrial cleaning Break wash cold 10 min Main wash 60C 6 min Main wash 70C 10 min Extraction 2 min 3 cold rinses Extraction 5 min Domestic cleaning Pre wash cold Main wash 70C 10 min Extraction 2 min Cold rinses TUMBLE DRYING OR TUNNEL DRYING IS NOT RECOMMENDED Mattress cells can be wiped with a solution of sodium hypochlorite 1000ppm or any other non phenolic germicidal solution Note The control unit should also be cleaned weekly using a damp soft cloth and mild detergent
3. 1 cycle meaning 2 8rds of the body is always supported at any one time The DynaLAL system offers deep cell therapy whereby the cells completely collapse providing 0 pressure at the point of deflation The soft firm adjustment allows the patient to adjust the firmness or softness of the surface for optimal comfort through 8 digital scales The surface also has 2 inches of enclosed convoluted foam to provide extra protection and comfort for the patient in the event of a power failure and the mattress deflates User Manual DynaLAL ahead of the curve 3 1 Alternation Cycle Illustration 18 celis 1 3 of cushions are deflated 18 cells fully inflated 18 cells 1 3 of cushions are deflated 18 cells fully inflated 18 cells 1 3 of cushions are deflated 18 cells fully inflated Control Unit Features pump Alternating time can be adjusted in 5min increments to 95 min In addition the caregiver can select the Static Function stopping the alternating function and providing only low air loss therapy The auto firm function provides uniform firmness for nursing procedures Power failures produce an audio alarm for added safety The alarm can be disabled by pushing the ALARM RESET Button on the front panel ALARM RESET o power CAREMED SUPPLY INC Double insulation provides near silent operation Foot board mounting rack provides convenient placement on bed User Manual DynaLAL ahead of t
4. All of the air will be expelled Starting at the head of the mattress roll towards the foot of the bed Use the base mounted straps to secure It is recommended that the following guidelines are used whenever the system is being stored or transported to another location Temperature limitations 5C to 60C Relative humidity 30 to 75 2 Maintenance and Troubleshooting No daily maintenance is required This equipment should only be serviced by authorized technical personnel In case of minor problems refer to the following Inspection Procedure Possible Solution Symptom The air is flowing out from the control unit but 1 Is the power source correct Improper voltage may 1 Use power regulator the mattress is not inflating cause the pump to function abnormally and damage the control unit 2 Do the air tubes allow smooth airflow Is an air tube kinked 2 Adjust the air tubes to enable smooth 3 Is there any air leakage from the air cells air flow 4 Is there any air leakage from air tube between 3 Replace with new air cells mattress and control unit Has the air tube connector been connected properly 4 Replace with new air tubes oa User Manual DynaLAL EA Overs ahead of the curve 5 Re connect the air tubes The Control Unit is not working 1 Check the power cord and the power voltage 1 Use a power regulator 2 Check the fuse 2 Replace with a new fuse Some air cells have abnorma
5. Switch off the electrical supply to the pump and disconnect the power cord from the main supply before cleaning and inspection The Pump The casing of the pump is manufactured from ABS plastic If soiled it can be wiped down with a sodium hypochlorite solution to dilution of 1000ppm or any EPA approved hospital grade disinfectant Do not use phenol based cleaning solutions User Manual DynaLAL ahead of the curve Cleaning procedure for air filter 1 Air Filter is located at the back of the control unit inside the carry handle No tools are required to remove it Air Filter must be removed for inspection at least once a month and washed under running tap water if necessary Squeeze to remove excess water before reinstalling it 2 Use a soft brush to remove dust and debris from the air intake muffler prior to reinstalling the filter 3 New filters are also available Do not use phenol based cleaning solutions Switch off the electrical supply to the pump and disconnect the power cord from the main supply before cleaning and inspection 4 Storage and Care Control Unit Check the power cord and plug for abrasions and excessive wear Plug in the unit and verify air flow from the hose connection ports Place in plastic bag for storage Mattress Replacement System Check the air manifold for kinks or breaks Replace if necessary Twist open the CPR plug at the head of the mattress and disconnect the air feed tubes
6. User Manual DynaLAL ahead of the curve Dynamic Low Air Loss DynaLAL Alternating Pressure Relief User Manual Distributed by Quart Healthcare Inc www quarthealthcare com User Manual DynaLAL ahead of the curve 7 KSA 7 KSA gt Warning Connect the Master Control unit to an appropriate power source Do not use the system in the presence of any flammable gases such as anesthetic agents Keep the pump and mattress away from sources of liquid and open flames Keep mattress away from sharp objects The device is not AP APG protected Keep mattress system away from heating devices Caution Consult clinical instructor before use of mattress Support surfaces should always be used in conjunction with a care plan that includes the turning repositioning of the patient over a 24 hour period The control unit should only be repaired by an authorized distributor Do not drop the control unit or store it in direct sunlight or extreme cold conditions Product Description The DynaLAL system is a unique and innovative specialized mattress replacement unit The system utilizes low air loss technology with a high flow rate that provides pressure management for the treatment of pressure ulcers The advanced 3 1 alternating function also provides active prevention for pressure relief especially for those in acute care and long term care settings the cells inflate and deflate in a 3
7. he curve Master Control Unit Part No FC QHI0079 Device Identifier Health Canada FC CRP0079 Size cm 42 L x17 W x27 H Weight Kg 6 1 Phase Time 5 95 Rated Voltage 120 volt Fuse Rating T5AH 250V Max Current 18W Rated Frequency 60 Hz Protection Type Classification UL60601 1 Class Type BF Classification to Health Canada Class Il Operation Temperature 15c 40c Mode of Operation Continuous Safety Standard UL CSA Mattress Replacement Features Individual air cushion design for maximum pressure distribution Air cells are vented to provide true low air loss therapy with a high flow rate Individual air cushion design for maximum pressure distribution Alternating Mattress Replacement Features Part No FM QHI0001 Device Identifier Health Canada FM CRP0001 Size cm 89 W x203 L x24 H 36 x 80 x 9 5 Weight Kg 17 5 Kg Part No FM QHI0005 Device Identifier FM CRP0005 Health Canada Size cm 122 W x203 L x24 H 48 x 80 x 9 5 Weight Kg 21 0 Kg Cells Material PU Cover Type Zipper cover with removable foam base Cover Material Nylon knitted fabric w PU coating finish Base Material Woven Polyester fabric w PVC backing User Manual DynaLAL ahead of the curve 2 Instructions for Proper Use iii iv
8. l low air pressure 1 Is the connection between air cells and the manifold 1 Adjust the connection between cells while the air pressure for other air cells is kinked and manifold normal 2 Is there any air leakage from the air cells 2 Replace with a new air cell 3 Warranty Quart Healthcare Inc guarantees that this equipment is free from defects in materials and workmanship Our obligation under this warranty is limited to the repair of equipment returned to the place of purchase within 24 months of delivery date We agree to service adjust any equipment returned and to replace or repair any part that is proven to be a warranty defect at no charge This warranty excludes equipment damage through shipping tampering improper maintenance carelessness accident negligence or misuse or products that have been altered repaired or dismantled other than with the manufacture s written authorization and by its approved procedures and by properly qualified technicians In no event shall Quart Healthcare Inc be liable for any direct indirect or consequential damages or losses resulting from the use of equipment