Home
        chroma-q db4 - Point Source Productions Ltd
         Contents
1.    All grouped no FX   RGB     Out2 address  The Color Block fixtures are self addressing in order of connection   However if the XLR4 OUT2 is used a fixture number offset can be selected  Press Enter   turn wheel to select offset 1 5  press Enter for 2 seconds to save     Look  The Colour Block has 9 internal FX memories for standalone operation   To replay  a Look  press Enter and scroll through the 9 Looks  To record a Look  DMX must be  present  Press Enter  scroll to desired Look  Press Enter to enter the desired Look location  and press Enter for 2 seconds to save    Note  DMX has priority over internal Looks  For recording editing Looks without a separate  console  please see the full User manual available from www aclighting com     Lost DMX  If DMX is not detected the following output options can be selected  Off  Hold  output  Look1 9  Press Enter  turn wheel to selection  press Enter for 2 seconds to save       diSP    Display  The LED can be set to Off after 5 seconds  Press Enter  turn wheel to selection       rESEt    O  Grouped individually    press Enter for 2 seconds to save    Reset  Press Enter for 2 seconds to reset all menu items to factory defaults   DMX address   001  Control   1  Out2   1  default 9 Looks  Lost   Hold  Display   On    Grouped as Blocks Grouped as One    Group Huet Red1 Speed Hue1 Red1 Speed Hue Red1    Green1 Fan Sat 1 Green1 Fan Sat 1 Green1    Speed Sat 1    Fan Int 1 Blue Range Int 1 Blue Range Int 1 Blue    Range Hue2 Red2 Step Hue
2. 2 Red2 Step    Step Sat 2 Green2 Int  FX Sat 2 Green2 Int  FX    Int  FX Int 2 Blue2 Int  Fan Int 2 Blue2 Int  Fan    Int  Fan Hue3 Red3 Hue Hue3 Red3 Hue1  Green3 Sat 1    Hue1 Sat 3 Green3 Sat 1 Sat 3    Sat 1 Int 3 Blues Int 1 Int 3 Blues Int 1    Int 1 Hue3 Red4 Hue2 Hue3 Red4    Hue2 Sat 3 Green4 Sat 2 Sat 3 Green4  Sat 2 Int 3 Blue4 Int 2 Int 3 Blue4  Int 2 Hue 4 Red5 Hue3 Hue 4 Red5    and so on up to        
3. EQUIPMENT ON HIRE FROM POINT SOURCE PRODUCTIONS LTD   TEL   44  0 20 8661 7200   FAX   44 0  8701 696736   EMAIL  HIRES PSLX CO UK    Color Block System Overview    The Color Block s modular design and comprehensive range of fixing options allows users to easily  create a complete LED system using stock of just one generic fixture type   including battens  blinders  and various mounting configurations using the built in fixing  Each block features four sets of 3 high  output LEDs which produce an intense  powerful light and vibrant colours across the spectrum     Designed to be intelligent both inside and out  the modular blocks incorporate the latest HSI  Hue   Saturation and Intensity  control as well as RGB  and Variable Effects Engine software which gives the  lighting designer full control over colour and effects combinations     The product s lightweight yet robust  heavy gauge aluminium extruded construction houses a discreet  cable management system and additional protection is built around the LED lenses for a truly road proof  fixture     Color Block PSU    The Color Block PSU supplies power and data for up to 5 Color Block fixtures via a XLR4 connector  The  units daisy chain to a maximum of 5 Color Blocks per Color Block PSU  Each chain must return to the  PSU from the last unit as shown below  The total cable length of each chain must not exceed 60mtrs     pm     TE  psu pE Foto       Color Block 1 Color Block 2 Color Block 3 Color Block 4 Color Block 5    Note  
4. maximum of 5 Color Block fixtures to each PSU    Connection Cables   The Color Block utilises an XLR 4 pin cable system  This is used to supply power and control data   Pin 1   OVDC  pin 2   control minus  pin 3   control plus  pin 4    48VDC  The chassis should be  ground bonded     Control Menu   The Color Block PSU access    menu items via the red LED display and the following controls     Right hand button   Enter  hold for 2 seconds to save     Left hand button   Exit without saving    Wheel   Adjusts values or cycles through menu items       Menu Options     Adr     DMX Address  To set the DMX start address of the Color Block PSU  press Enter  turn  wheel to adjust DMX start address  press Enter for 2 seconds to save     Control  The Color Block PSU can be set to operate in various DMX controlled modes   We offer 3 grouping options  individual  block  all  with 3 control options on each  FX   HSI  amp  RGB  see table below for details  Press Enter  turn wheel to select control mode   press Enter for 2 seconds to save       contri    Color Block instruction sheet v0 4      out2        Looc      LoSt    Mode 1  67ch    Individually grouped with FX   HSI  Mode 2  60ch    Individually grouped no FX  HSI  Mode 3  60ch    Individually grouped no FX   RGB  Mode 4  21ch    Block grouped with FX   HSI  Mode 5  15ch    Block grouped no FX   HSI   Mode 6  15ch    Block grouped no FX   RGB  Mode 7  9ch    All grouped with FX   HSI   Mode 8  3    All grouped no FX   HSI   Mode 9  3 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Boxlight Seattle X40N LCD x3 Projector User Guide Manual  Bedienungsanleitung  9608 Handbuch CallCenter  Instrucciones para el uso del equipo adicional  Service Manual - System 2000 Winchester Disk Controller  agence pour la promotion et le developpement economique    Sharp AR-C360P Owner's Manual  OPERATOR`S MANUAL MANUEL de L`UTILISATEUR MANUAL del  Black & Decker T2200-T2450 Use & Care Manual    Copyright © All rights reserved. 
   Failed to retrieve file