1. Install the User s Manual Installation Guide so that you can access all the installation configuration and operating information about the unit e Print sections you may want to reference User s Manual Installation Guide The manual is in PDF file format Your PC should be using Microsoft Windows 3 1 or above and have Adobe Acrobat Reader installed for browsing or printing this manual Adobe Acrobat Reader may be obtained free from Adobe Systems Incorporated from their Web Site at www adobe com Using Adobe Acrobat Reader Adobe Acrobat Reader is used just as you would most word processing or text editing programs Start Adobe Acrobat Reader and open the file containing the FrameSaver NP User s Manual Installation Guide You can simply scroll through the pages or use the Bookmarks along the left side to move around the manual or the tables in the front of the manual To print the manual or a selection of pages select Print from the File menu and then select the range of pages you wish to print Select OK to begin printing Ordering a Hard Copy of the User s Manual Contact Paradyne Corporation at the address on the back of this Guide to obtain a print ed copy of a FrameSaver NP User s Manual Installation Guide Always specify the latest revision for each publication number Safety Instructions Before proceeding with the installation carefully read the Equipment Interference No tice Important Safety
2. LED is ON steady after UNIT READY and ISDN READY completion of self test LEDs are ON steady after completion of self test NETW ALARM and UNIT FRM MGMT LEDs should not be flashing together All other LED indications should be ignored at this time If the LED indications are not as described above refer to Section 5 Diagnostics of the FrameSaver NP 110 User s Manual Installation Guide If operation looks nor mal unplug the FrameSaver NP before making input output connections If the unit is to supply switched power to another device plug that device s power cord into the Switched AC Out connector now Proceed to Making Network and Input Output Connections on page 9 of this guide 7 Power Up a FrameSaver NP 120 Power Connections 1 Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP CAUTION AC Power Con nector FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE IEC 320 male ES Cae 100 240 VAC 5A 50 60 Hz aiie Te 0000000000 e QO0000000C elle 0000000001 En I FUSE AEETI 2 Plug the other end of the Power 2A 250V SLOW BLOW CONFIGURATION e USER POR Cord into an AC outlet Zau TPUT 3 The unit will go through the following power up sequence FrameSaver NP 120 Power Up Sequence FrameSaver NP 120 POWER LED lights
3. and stays on READY LED flashes during self test approximately 30 seconds READY LED is ON steady after completion of self test The NETWORK ALARM and FR MGMT LEDs should not be flashing together Refer to User s Manual Installation Guide if they are All other LED indications should be ignored at this time If the LED indications are not as described above refer to Section 5 Diagnostics of the FrameSaver NP 120 User s Manual Installation Guide If operation looks nor mal unplug the FrameSaver NP before making input output connections If an optional Power Control Unit PCU is to be installed with this FrameSaver NP refer to instructions provided with the PCU and install 1t now Proceed to Making Network and Input Output Connections on the next page of this guide Making Network and Input Output Connections CAUTION Be sure you remove AC power from the FrameSaver NP before attaching input and output cables All connectors are located on the FrameSaver NP s rear panel Make all the necessary connections using the cables listed for that model CAUTION Use caution when connecting to an AUX Port AUX Port connectors are similar to the Network connectors Accidental connection of either of the AUX Ports to a Network facility may damage the AUX Port electrical interface NOTES L FrameSaver NP 64 100 and 120 Data and User Ports support numerous electrical interface types ITU V 35 EIA 530 EI
4. 15 Trademarks FrameSaver is a registered trademark of Paradyne Corporation All other products systems or services mentioned in this document are trademarks service marks regis tered trademarks or registered service marks of their respective owners Copyright Notice O Copyright 1999 2000 Paradyne Corporation All rights reserved Sales Service and Warranty Information Contact your local service representative distributor or sales representative for addi tional information or help concerning service repair installation documentation war ranty or sales Or contact Paradyne Corporation at e Telephone 201 703 4800 Internet http www paradyne com e FAX 201 703 4889 e Mail Paradyne Corporation 16 00 Pollitt Drive Fair Lawn NJ 07410 PARADY NE 16
5. A 530 A ITU X 21 NS and EIA 232 FrameSaver NP 64 only The Data Port connector is a DB 44 high density female The adapter cables listed for each model are used to convert from the DB 44 to the appropriate connector type for the interface selected The adapter cable also includes a special wiring pattern at the DB 44 connector which automatically sets the port to the desired interface type Refer to the tables on pages 13 15 of this guide for cable ordering information if necessary FrameSaver NP 110 User and Data Ports are configured for ITU V 35 Interface FrameSaver NP 120 is designed for use in networks where it is not directly connected to the local PTT s non U S facilities All the Network connections are made to the customer s Private Network Making ISDN Option Connections FrameSaver NP units equipped with optional ISDN adapters have additional connec tors on the rear panel for ISDN Line s and ISDN Data Port DTE The ISDN Data Port supports the same electrical interface types and uses the same connector as the base unit Data Port Making DROP DSX Option Connections FrameSaver NP 110 only FrameSaver NP 110 units equipped with optional DROP DSX adapters have addition al connectors on the rear panel for the DROP and DSX Ports The DROP Port supports the ITU V 35 interface and the DSX Port is aT1 Network interface FrameSaver NP 64 Specifications tem Description Dimensions Operating Range Power Re
6. Instructions and Preface sections of the FrameSaver NP User s Manual Installation Guide Before You Begin Ensure you have the following e A dedicated grounded circuit breaker protected power outlet within six feet of the FrameSaver NP unit e A suitable location for the unit that is clean well lit ventilated and free from environmental extremes e One to two feet of clearance for cable connections to the unit Package Checklist Verify that the packaging contains the following e FrameSaver NP unit e Unit power cord or AC Power Pack with cord e If ordered optional wall mount or rack mount bracket assembly In addition you will need Input Output cables if not already supplied These cables are listed for each FrameSaver NP Model on pages 13 15 of this guide Mounting the FrameSaver NP FrameSaver NP units come equipped with rubber feet for table or shelf top placement Optional adapter brackets are available for wall mounting Model 64 includes wall mount key holes in its base and standard 19 or 24 rack mounting To attach and mount adapter brackets follow the instructions supplied with the mounting adapters Allow sufficient space for cooling and access to the front panel indicators for trouble shooting in all installations Power Up a FrameSaver NP 64 Make Power Connections 1 Plug the 2 pin keyed and locking connector at the end of the cord from the AC Power Pack into the right most pins of the 4 pi
7. PARADY NE FrameSaver NP Installation amp Quick Reference Guide FrameSaver NP Models 64 100 110 and 120 Document Number 980 000 0272B August 2000 This Quick Reference Guide provides an overview on how to install a FrameSaver NP Model 64 100 110 or 120 unit This includes making the physical connections be tween the unit network DTE device s and telephone line It also tells you how to find more detailed information about your FrameSaver NP Product Documentation on the World Wide Web We provide complete product documentation online This lets you search the docu mentation for specific topics and print only what you need reducing the waste of sur plus printing It also helps us provide timely product update information and maintain competitive prices for our products Complete documentation for these products is available at www paradyne com Select Library gt Technical Manuals gt FrameSaver NP NetPath Frame Relay Digital Access Units Select the appropriate document from the documentation list FrameSaver NP 64 User s Manual Installation Guide Publication 980 001 0221 FrameSaver NP 100 User s Manual Installation Guide Publication 980 001 0210 FrameSaver NP 110 User s Manual Installation Guide Publication 980 001 0240 FrameSaver NP 120 User s Manual Installation Guide Publication 980 001 0230 1 Getting Started Before installing or starting to use the FrameSaver NP you should e
8. R MGMT LEDs should not be flashing together All other LED indications should be ignored at this time If the LED indications are not as described above refer to Section 5 Diagnostics of the FrameSaver NP 64 User s Manual Installation Guide If operation looks normal unplug the FrameSaver NP before making input output con nections If an optional Power Control Unit PCU is to be installed with this FrameSaver NP refer to the instructions provided with the PCU and install it now Proceed to Making Network and Input Output Connections on page 9 of this guide Power Up a FrameSaver NP 100 Power Connections 1 Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP AC Power Connector IEC 320 male 90 250 VAC 5A 50 60 Hz 2A 250V SLOW BLOW CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE 012345678 9101112 01 2 fe e 0000000000 REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE N l N 0000000001 A i A elle 0000000001 CONFIGURATION CONTROL DATA POR OUTPUT 2 Plug the other end of the Power Cord into an AC outlet 3 The unit will go through the following power up sequence FrameSaver NP 100 Power Up Sequence Basic FrameSaver NP 100 FrameSaver NP 100 with ISDN POWER LED lights and stays on READY LED flashes during self test READY and ISDN READY LEDs approximately 60 se
9. conds flash during self test approximately 60 seconds READY LED is ON steady after READY and ISDN READY LEDs are completion of self test ON steady after completion of self test The T1 ALARM and FR MGMT LEDs should not be flashing together All other LED indications should be ignored at this time If the LED indications are not as described above refer to Section 5 Diagnostics of the FrameSaver NP 100 User s Manual Installation Guide If operation looks nor mal unplug the FrameSaver NP before making input output connections If an optional Power Control Unit PCU is to be installed with this FrameSaver NP refer to instructions provided with the PCU and install it now Proceed to Making Network and Input Output Connections on page 9 of this guide 6 Power Up a FrameSaver NP 110 Power Connections 1 Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP 120 AC Power Connector IEC 320 male USER PORT ORO ROO OCIO m 00000000 A OOTO OOO OOOO 2 Plug the other end of the Power Cord into an AC outlet 3 The unit will go through the following power up sequence FrameSaver NP 110 Power Up Sequence Basic FrameSaver NP 110 FrameSaver NP 110 with ISDN UNIT POWER LED lights and stays on UNIT READY LED flashes during UNIT READY and ISDN READY self test approximately 60 seconds LEDs flash during self test approximately 60 seconds UNIT READY
10. dity 5 to 95 non condensing Altitude 10 000 ft max operating 50 000 ft max non operating Shock and Vibration As normally encountered during shipping and handling Power AC Input 100 240 VAC 50 60 Hz 5 0A max Requirements 0 5A max for the unit s internal power requirements 4 5 A max for device if any connected to the Switched AC Output Fused 5A 250V Slow Blow 5x20mm Switched AC Output max 250 VAC 4 5 A CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE ONLY WITH THE SAME TYPE AND RATING ATTENTION POUR NE PAS COMPROMETTRE LA PROTECTION CONTRE LE RISQUE D INCENDIE REMPLACER PAR UN FUSIBLE DE MEMES TYPE ET CARACTERISTIQUE NOMINALES Regulatory UL 1950 Third Edition and CAN CSA C22 2 No 950 95 Compliance Third Edition FCC Part 15 Class A Digital Device Canada s ICES003 Class A Digital Device FCC Part 68 12 FrameSaver NP 64 Cable List eses Pao ITU V 35 Data Port DTE cable to Cisco router serial port 135 006 0400 HD 60 connector Contact your service representative distributor or sales representative to order cables 13 FrameSaver NP 100 120 Cable List semis Paros HD 60 connector NP 100 only A a S000 Contact your service representative distributor or sales representative to order cables 14 FrameSaver NP 110 Cable List senil PartNo Contact your service representative distributor or sales representative to order cables
11. n Power Connector located on the rear of the FrameSaver NP 64 just to the right of the alert marking CAUTION The power connectors are keyed and fit easily together when oriented correctly with the locking clip toward the top of the unit Do not force the connectors together Blocking Safety Plug Remove only when installing optional Power Control Unit DIGITS al DATA PORT 00 x10 x1 34567 8 9101112 000000000000000 000000000000000 00000000000000 X gt 0 SV gt Plug into RIGHT side Pins ONLY 2 Pin Connector from ower Pack CAUTION The 2 pin keyed plug fits easily into the two RIGHT SIDE pins of the 4 pin Power Connector and must only be inserted there The FrameSaver NP unit will be damaged if the plug is forced into the other side 4 2 Plug the Power Pac at the other end of the power cord into an AC outlet 3 The unit will go through the following power up sequence FrameSaver NP 64 Power Up Sequence Basic FrameSaver NP 64 FrameSaver NP 64 with ISDN READY LED may flash several times READY and ISDN READY LEDs then remain OFF during self test may flash several times then remain approximately 43 seconds OFF during self test approximately 45 seconds READY LED is ON steady after READY and ISDN READY LEDs are completion of self test ON steady after completion of self test The DDS ALARM and F
12. quirements Regulatory Compliance Table Top with rubber feet 3 0 H x 8 5 W x 11 5 D Wall Mount with removable wall mounting bracket 8 5 H x 11 5 W x 3 0 D Rack Mount with removable rack mounting adapter 3 5 H x 19 0 W or 24 0 W x 11 5 D As normally packaged including carton and accessories 6 lbs Unit alone without packaging and accessories 4 lbs Temperature 0 to 50 degrees C operating Relative Humidity 5 to 95 non condensing Altitude 10 000 ft max operating 50 000 ft max non operating Shock and Vibration As normally encountered during shipping and handling AC Power Pack transformer plug module Input 90 130 VAC 0 2 A max 60 Hz Output 22 VAC 30 VA Cable 2 conductor with 2 pin keyed locking connector 7 ft length UL 1459 Third Edition and CAN CSA C22 2 No 225 M90 FCC Part 15 Class A Digital Device Canada s ICES003 Class A Digital Device FCC Part 68 10 FrameSaver NP 100 120 Specifications tem Description __ Dimensions Table Top with rubber feet 3 5 Hx 10 5 W x 12 0 D Wall Mount with removable wall mounting bracket 10 5 H x 12 0 W x 3 5 D Rack Mount with removable rack mounting adapter 5 25 H x 19 0 W or 24 0 W x 12 0 D As normally packaged including carton and accessories 8 lbs Unit alone without packaging and accessories 6 lbs Operating Temperature 0 to 50 degrees C operating Range Relative H
13. umidity 5 to 95 non condensing Altitude 10 000 ft max operating 50 000 ft max non operating Shock and Vibration As normally encountered during shipping and handling Power 90 250 VAC 50 60 Hz 15 Watts max Requirements 100 240 VAC for FrameSaver NP 120 Fused 2A 250V Slow Blow 5x20mm CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE ONLY WITH THE SAME TYPE AND RATING ATTENTION POUR NE PAS COMPROMETTRE LA PROTECTION CONTRE LE RISQUE D INCENDIE REMPLACER PAR UN FUSIBLE DE MEMES TYPE ET CARACTERISTIQUE NOMINALES Regulatory FrameSaver NP 100 UL 1459 Third Edition and CAN CSA Compliance C22 2 No 225 M90 FCC Part 15 Class A Digital Device FCC part 68 Canada s ICESO003 Class A Digital Device FrameSaver NP 120 UL 1950 CAN CSA C22 2 No 225 M90 FCC Part 15 Class B Digital Device Canada s ICES003 Class A Digital Device EN 60950 EN 50082 1 1992 EN 55022 1995 EMI EN 55022 Class B 11 FrameSaver NP 110 Specifications hem Description Dimensions Table Top with rubber feet 3 5 H x 10 5 W x 12 0 D Wall Mount with removable wall mounting bracket 10 5 H x 12 0 W x 3 5 D Rack Mount with removable rack mounting adapter 5 25 H x 19 0 W or 24 0 W x 12 0 D As normally packaged including carton and accessories 8 lbs Unit alone without packaging and accessories 6 Ibs Operating Temperature 0 to 50 degrees C operating Range Relative Humi