Home

User manUal

image

Contents

1. COMPONENT IDENTIFICATION Auxiliary Gas Burners Semi rapid burner Rapid burner Triple ring burner Igniter for Gas Burners only on certain models Safety Device Flame Failure only on certain models activates if the flame accidentally goes out spills drafts etc interrupting the delivery of gas to the burner Control Knobs for Gas Burners Oo oF WN N tisira www tisira com NOTICE Must be installed by an authorized person accordance with AS5601 gas installations local authority and any other statutory regulations The following instructions are directed at the qualified installer so that the installation and maintenance procedures may be followed in the most professional and expert manner possible IMPORTANT Ensure appliance is disconnected from the electrical supply before performing any maintenance or regulation upkeep work Cas inlet is located at the rear right OR left hand side depending on the model 25mm from the rear edge Electrical terminal is located at the rear centre 50mm from the rear edge Fixing brackets are provided which allow the hob the hob to be installed in 20 40mm benchtops It is recommend to use all supplied brackets to ensure that the hob is secularly installed Bracket Position Bracket Position Bracket Position 20mm top 30mm top 40mm top www tisira com tisira 1 INSTALLATION
2. USER MANUAL 300 600 amp 900 GAS HOBS TGF30 TG60 TGW60 TOWF40 TEWF9O IMPORTANT Please ensure that you read through this user manual prior to installation and use This manual contains important information to ensure optimal performance and keep you safe Please retain your proof of purchase as this will be required in the event that you require warranty service Remember to retain this manual for future reference HELLO CONGRATULATIONS ON THE SELECTION OF THIS TISIRA APPLIANCE TISIRA APPLIANCES HAVE BEEN SPECIFICALLY DESIGNED FOR AUSTRALIAN AND NEW ZEALAND KITCHENS Please read through this user manual carefully as it contains information that will ensure that your appliance is installed correctly important operating amp care Instructions and also some advice of what you need to do if this appliance is not performing as intended www tisira com tisira 1 CONTENTS HELLO CONTENTS WARNING amp SAFETY INFORMATION PRODUCT OVERVIEW INSTALLATION OPERATING INSTRUCTIONS MAINTAINING YOUR COOKTOP PRODUCT SPECIFICATIONS WARRANTY TERMS amp CONDITIONS PROOF OF PURCHASE NOTES CONTACT DETAILS tisira www tisira com amp co MN 6 11 12 13 14 15 16 17 18 19 20 pg 4 WARNING amp SAFEIY INFORMATION DO NOT MODIFY THIS APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION DO NOT STORE OR USE FLA
3. Green amp Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug proceed as follows Connect the Green amp Yellow wire to terminal marked E or coloured Green or Green 8 Yellow Connect the Brown wire to the terminal marked L or coloured Red Connect the Blue wire to the terminal marked N or coloured Black www tisira com tisira 1 INSTALLATION GAS CONVERSION NATURAL GAS AND ULPG The cooktop is factory fitted with Natural Gas Injectors To adapt the cooktop to a different type of gas than that for which it was designed see the sticker under the hob or on the packaging the burner nozzles must be changed as follows Remove the pan supports and slide the burners out of the cooktop Unscrew the nozzles using a 7mm socket wrench and replace them with those for the new type of gas See the product specification Burner and Nozzle Specifications Reassemble the parts following the instructions in reverse order completing the operation replace the old rating label with the one showing the new type of gas the sticker is available from our Service Centres If the gas pressure is different than that prescribed a pressure regulator must be installed at the source in compliance with national standards governing the use of piped gas regulators REGULATION OF AIR SUPPLY
4. POSITIONING FOR GAS HOB IMPORTANT This unit may be installed and used only in permanently ventilated rooms in accordance with AS5601 gas installations Local authority and any other statutory regulations The following requirements must be observed room must be fitted with a ventilation system which vents smoke and gases from combustion to the outside his must be done by means of a hood or electric ventilator that turns on automatically each time the hood is operated In a chimney stack or Directly to the outside branched flue Exclusively for cooking appliances The room must also allow for the influx of the air needed for proper combustion The flow of air for combustion purposes must not be less than 2m3 h per kW of installed capacity The supply of said air can be affected by means of direct influx from the outside through a duct with a inner cross section of at least 100cm2 which must not be able to be accidentally blocked Those appliances which are not fitted with a safety device to prevent the flame from accidentally going out must have a ventilation opening twice the size otherwise required i e a minimum of 200 cm2 Fig Otherwise the room can be vented indirectly through adjacent rooms fitted with ventilation ducts to the outside as described above as long as the adjacent rooms are not shared areas bedrooms or present the risk of fire Fig B Detail A Adjacent Room Room to be vented Examples of
5. Ventilation A Enlarging the Ventilation Holes for comburant air 3 slots between the window Fig A and floor Fig B INSTALLATION C Intensive and prolonged use of the appliance may necessitate supplemental ventilation e g opening a window or increasing the power of the air intake system if present D Liquefied petroleum gases are heavier than air and as a result settle downwards Rooms in which LPG tanks are installed must be fitted with ventilation openings to the outside in order to allow the gas to escape in the event of a leak Therefore LPG tanks whether empty or partially full must not be installed or stored in rooms or spaces below ground level cellars etc It is also a good idea to keep only the tank currently being used in the room making sure that it is not near sources of heat ovens fireplaces stoves etc that could raise the internal temperature of the tank above 50 C E Overhead clearances Measurement A Rangehoods and exhaust fans shall be installed in accordance with the manufacturer s relevant instructions However in no case shall the clearance between the highest part of the hob of the gas cooking appliance and a range hood be less than 600 mm or for an overhead exhaust fan 750 mm Side clearances Measurements B amp C Where B measured from the periphery of the nearest burner to any vertical combustible surface or vertical combustible surface covered with toughened glass or s
6. knob and try to light it again after waiting at least 1 minute To turn off a burner turn the knob in the clockwise direction until it stops it should be on the off setting GENERAL ADVICE For best performance follow these general guidelines e Use the appropriate cookware for each burner see table in order to prevent the flame from reaching the sides of the pot or pan e Always use cookware with a flat bottom and keep the lid on e When the contents come to a boil turn the knob to Low www tisira com tisira 1 OPERATING INSTRUCTIONS BURNER COOKWARE DIAMETER RAPID 24 26 SEMI RAPID 16 20 AUXILIARY 10 14 TRIPLE RING WOK 24 26 Use cookware the diameter of which is at least as large as the cooking area so that all of the heat produced by the burner is used tisira www tisira com FIM MAINTAINING YOUR COOKTOP GENERAL MAINTENANCE Before cleaning or performing maintenance on your appliance disconnect it from the electrical power supply To extend the life of the cooktop it is Important that it be cleaned carefully and thoroughly on a frequent basis keeping in mind the following e The enameled cast iron and stainless steel parts must be washed with warm water without using abrasive powders cloths or corrosive substances which could ruin them e he removable parts of the burners should be washed frequently with warm water and soap making sure
7. MMABLE MATERIALS IN THE APPLIANCE STORAGE DRAWER OR NEAR THIS APPLIANCE Servicing should be carried out only by authorised personnel Where this appliance is installed in marine craft or in caravans it shall not be used as a space heater Do not remove the plug by pulling the cable In order to prevent accidental tipping of the appliance for example by a child climbing onto the open oven door the anti tilting chain must be installed Refer to the instructions on page 14 To avoid burns young children should be kept away This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or Instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Accessible parts may become hot when the grill is in use Children should be kept away Very important keep this instruction booklet with the appliance for handy references This appliance is designed for domestic use only Keep packaging out of reach of children at all times www tisira com tisira 1
8. TO THE BURNER The burners do not need any primary air regulator SETTING THE MINIMUM REGULATION NOTICE In the case of liquid gas the regulation screw must be fully screwed in clockwise Turn the gas valve to minimum Remove the knob and turn the regulator screw positioned either on the side of the top or inside the shaft Fig A and B clockwise until the flame becomes small but regular Make sure that when the knob is turned rapidly high to Low the flame does not go out In the event of a malfunction on appliances with the security device thermocouple when the gas supply is set at minimum increase the minimum supply levels using the regulator screw in Fig Once the adjustment has been made apply sealing wax or a suitable substitute to the old seals on the by pass OPERATING INSTRUCTIONS The position of the corresponding gas burner is indicated on each control knob GAS BURNERS The burners differ in size and power Choose the most appropriate one for the diameter of the cookware being used burner can be regulated with the corresponding control knob by using one of tile following settings 1 Off 2 High 3 Low To light a burner simply press the corresponding knob all the way in and then turn it in the counter clockwise direction to the High setting keeping it pressed in until the burner lights CAUTION If the burner accidentally goes out turn off the gas with the control
9. d Relative This warranty will not apply where The fault is caused by accident misuse oversuds an infestation of vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a failure to comply with the manufacturer s operating and installation instructions c Service modification or repair has been carried out by anybody other than an approved Tisira Service Technician d The appliance has been used installed anywhere other than a private dwelling or where it has been used other than for domestic use The appliance is subject to a rental agreement Any defective part that has been replaced becomes the property of Arisit Pty Limited This warranty applies only to Tisira appliances purchased and installed in Australia and New Zealand Loss of use of the appliance or consequential loss of any nature is not covered A charge may be levied at the discretion of Arisit Pty Limited if the call is deemed unnecessary or if the cause of failure is traced to external sources such as but not limited to blown fuses power failure faulty installation etc Where the appliance the subject of a warranty claim or repair is used or installed more than TWENTY 20 kilometres from the nearest To register for your warranty please complete and return this form to Arisit Pty Limited within 30 days of purchase WARRANTY TERMS amp CONDITIONS Arisit Service Division or Authori
10. e must be tested by the installer before leaving Check all burner flames are blue in colour stable and completely ignite at both high and low flame settings with no appreciable yellow tipping carbon deposition lifting floatinglighting back or objectionable odour Test burners individually and in combination ELECTRICAL CONNECTION The cooktops fitted with a tripolar electrical supply cord are designed to be be used with alternating current according to the indications on the rating plate located under the cooktop earth wire can be identified by its yellow green colour In the case of installation over a built in electric oven the electrical connections for the cooktop and oven should be independent not only for safety purposes but also to facilitate removal of one or both in the future ELECTRICAL CONNECTION FOR GAS COOKTOP The supply cord has been fitted with a 10A 3 pin plug The power supply cord must be positioned so that it does not reach a temperature in excess of 50degC above room temperature at any point Before actual connection make sure that e The fuse and electrical system can withstand the load required by the appliance e That the electrical supply system is equipped with an efficient earth hook up according to the norms and regulations prescribed by law e That the plug and switch are easily accessible after installation Important the wires in the mains lead are coloured in accordance with the following code
11. eaf These Terms and Conditions apply only to Tisira products distributed in Australia and New Zealand by Arisit Pty Limited 1 This warranty applies for a period of 2 years parts and labour Australia and New Zealand commencing from date of purchase 2 Evidence of the date of purchase must be shown to the technician when he calls to obtain benefit under this warranty 3 This warranty applies only to the original purchaser hire purchaser of this appliance and cannot be assigned or transferred Failure to produce documentary proof of the date of original acquisition by the original purchaser will result in a charge being levied for work done labour and parts supplied 4 This warranty does not apply to a Serviceable items such as filters fuses light bulbs door seals drive belts external hoses etc b Damage to body work paint work glass trivets and plastic items such as but not limited to windows covers baskets trays worktops door handles control and kick panels c Corrosion amp rust damage d Damages blockages caused by laundry or foreign objects A fee for service will be charged following warranty claims where no fault is found with the appliance Where did you first hear about Tisira Advertising In Store Display Other please specify Please print in block letters Date of Purchase Name of Retailer zo Tradesman s Recommendation Recommendation by Frien
12. heet metal is less than 200 mm the surface shall be protected to a height C of not less than 150 mm above the hob for the full dimension width or depth of the cooking surface area Where the gas cooking appliance is fitted with a splashback protection of the rear wall is not required F In the event the cooktop is not installed above a built in oven a wood panel must be inserted as insulation This panel must be placed at least 20 mm from the bottom of the cooktop itself IMPORTANT When installing the hob above a built in oven the oven should be placed on two wooden strips in the case of a joining cabinet surface remember to leave a space of at least 45 x 560 mm at the back pg 8 www tisira com tisira 1 tisira www tisira com INSTALLATION When installing on a built in oven without forced ventilation ensure that there are air inlets and outlets for ventilating the interior of the cabinet adequately GAS CONNECTION FOR GAS HOB The gas cooktop should be connected to the gas supply by an authorised person only During installation of this product it is essential to fit an approved gas tap to isolate the supply from the appliance for the convenience of any subsequent removal or servicing Connection of the appliance to the gas mains or liquid gas must be carried out according to the prescribed regulation in force and only after it is ascertained that it is adaptable to the type of gas to be used If not fo
13. isira appliances Please specify Cooking Dishwashers Laundry AU Ms G tisira PROOF OF PURCHASE IE E EE E lC c cd accus lec cci ATTACH YOUR PROOF OF PURCHASE FOR FUTURE REFERENCE d reru NZ NOTES pg 18 www tisira com tisira ti NOTES tisira www tisira com TISIRA IS COMMITTED TO ONGOING RESEARCH AND DEVELOPMENT EVERY EFFORT HAS BEEN MADE TO ENSURE ALL INFORMATION IN THIS USER MANUAL IS CORRECT AT TIME OF GOING TO PRINT DIMENSIONS SHOULD BE USED AS A REFERENCE ONLY AND ACTUAL DIMENSIONS SHOULD BE TAKEN FROM THE PHYSICAL PRODUCT ONLY MANUFACTURER RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE CONTACT DETAILS AUSTRALIA ARISIT PTY LIMITED 40 44 Mark Anthony Drive Dandenong South VIC 3175 Australia P 1300 762 219 F 03 9768 0838 consumer care darisit com NEW ZEALAND ARISIT PTY LIMITED PO Box 68 140 Newton Auckland 1145 New Zealand P 09 306 1020 F 09 302 0077 sales daristonappliances co nz tisira wwwW tsira com au VERSION 1 2
14. llow the instructions indicated in the paragraph headed Adaptation to different gas types In the case of connection to liquid gas by tank use pressure regulators that conform to the regulation in force IMPORTANT For safety for the correct regulation of gas use and long life of the appliance ensure that the gas pressure conforms to the indications given in the Product Specification section of this manual under the heading Nozzle and burner characteristics CONNECTION TO NON FLEXIBLE TUBE Copper or Steel Connection to the gas source must be done in such a way as to not create any stress points at any part of the appliance The appliance is fitted with an adjustable L shaped connector and a gasket for the attachment to the gas supply Should this connector have to be turned the gasket must be replaced supplied with the appliance The feeding connector of the gas to the appliance is threaded 1 2 gas male cylinder CONNECTION TO FLEXIBLE HOSE The gas feed connector to the appliance is a threaded male 1 2 connector for round gas pipe Only use pipes and sealing gaskets that that conform to the standards currently in force Flexible hose must be certified to AS1869 class B or D 10mm in diameter and no longer than INSTALLATION 1200mm long The hose must not be kinked or be able to touch any hot surface The supply connection point must be accessible when installed GAS LEAKAGE AND OPERATION CHECK The applianc
15. sed Service Agent the cost of delivery to the nearest Service Division or travel costs for a technician or Authorised Service Agent shall be for the account of the Purchaser Where a built in appliance is located or installed outside the Arisit Authorised Service Agent s normal service area additional travel and labour costs shall be the account of the Purchaser 11 Arisit Pty Limited shall not under any circumstances be responsible in terms of this warranty for the replacement or repair of any part of the equipment which may have been damaged in transit during and after installation or imperfections after installation 12 Losses caused by act of God failure to obtain spare parts strikes or lockouts are not covered 13 Service is offered during normal working hours only also appliances to a have clear access in a serviceable area 14 This warranty does not effect your statutory rights 15 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure We reserve the right to amend any of the above without prior notice Would you like any further information on other Mrs Initials Surname T
16. to remove caked on substances e On cooktops with automatic ignition the end of the electronic ignition device must be cleaned carefully and frequently making sure that the gas holes are not clogged Stainless steel can be stained if it remains contact with highly calcareous water aggressive detergents containing phosphorous acid food or chemicals for an extended period of time it is recommended that these parts be rinsed thoroughly with water and then dried well It is also a good idea to clean up any spills immediately before they damage the surface SERVICING INSTRUCTIONS Always refer servicing to an authorised service person It is recommended that the appliance be serviced at least once per year to ensure the appliance continues to operate correctly and safety GREASING THE GAS VALVES Over time the gas valves may stick or become difficult to turn If this is the case they must be cleaned on the inside and the re greased NOTICE This procedure must be performed by an authorised service person pg 14 www tisira com tisira 1 PRODUCI SPECIFICATIONS BURNERS AND NOZZLE SPECIFICATIONS Small Medium ang Small Medium The appliance is supplied with duplicate data plate please attach to an adjacent surface for w o 2 e P la CO future reference tisira www tisira com FIM Cut this section and mail to the country of purchase see overl

Download Pdf Manuals

image

Related Search

Related Contents

Guida alle funzionalità di Fifth Generation iPod (Late 2006)  Tripp Lite AVR750U User's Manual  Blautherm® DUO Technische Hinweise  HMZ-Tー  um-floortec-r580b-de.. - Robe Reinigungsmaschinen  Philips SLE3400FN  ZZHUILES ESSENTIELLES COM  General Clog Chaser & Power Clog Chaser Operating Instructions  Colloque Expertise CHSCT et risques psychosociaux  Lava Computer LAVA SSerial-PCIe User's Manual  