Home

User Manual

image

Contents

1. Note Make sure to not use the Food Object Mode to measure body temperature ae 2 Hold the thermometer so the Infrared Sensor 7 Scan within Tip is positioned is at a distance within 1 2 inch 1 2 inch 1m from the food liquid or surface of your targeted measurement spot DO NOT let the Infrared Sensor Tip touch the target food or object Now press and hold the Ear Button ONLY and hold steady for approximately 2 3 seconds 3 Move the thermometer away from the object The LCD displays the measured temperature and indicates you ve made a Food Object A Temperature Measurement e To return to normal mode press the Forehead and Ear Buttons at the same time again or press the Memory Button It will return to normal mode automatically after 1 minute if you forget to do it yourself TEMPERATURE TAKING HINTS 1 A temperature measurement taken in the right ear may differ from a measurement taken in the left ear Therefore always take the temperature in the same ear 2 External factors may influence ear and forehead temperatures particularly when an individual has e been lying on the ear to be measured or has had it covered e been exposed to very hot or very cold temperatures e been recently swimming bathing or in any way causing the ear canal to become wet In these cases remove the individual from such circumstances and wait 30 minutes prior to taking a temperature 3 For persons wearing hearing aids or
2. F with a relative humidity of 20 85 20 C 55 C 4 F 131 F with a relative humidity of 20 90 This thermometer has been thoroughly tested and inspected to assure proper performance and operation CARE AND CLEANING VERY IMPORTANT To ensure accurate measurements keep the probe tip clean and free of scratches finger prints earwax or dirt or they will effect the accuracy of the thermometer To clean the probe tip gently wipe the clear surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab To clean the body of the thermometer use a soft dry cloth Never clean the ther mometer with an abrasive cleanser solvent thinner benzene etc or sub merge the thermometer into water or other liquids After cleaning store the thermometer in a clean dry place at room temperature Never expose the thermometer to extreme temperatures humidity or direct sun light Avoid any shocks drops or high impacts to the thermometer CALIBRATION The thermometer is initially calibrated at the time of manufacturing If the thermometer is used according to the instructions periodic recalibration is not required If at any time you question the accuracy of the measurement please contact the manufacturer immediately Don t attempt to modify or reassemble the thermometer EXPLANATION OF SYMBOLS xX Type BF Applied part K Disposal in accordance with Directive 2002
3. date of purchase Should this product prove to be defective at any time during the warranty period Mobi Technologies Inc will at its option either replace or repair it without charge After the warranty period a service charge will be applied for replacement of parts or labor for repair If you suspect that the product is malfunctioning or is defective please call Mobi toll free at 1 877 662 4462 and ask for the Service Department If the problem still persists after consulting with our Service Department you may return the product to obtain warranty service Please return it to Mobi along witha dated sales receipt from the place of purchase to varify that it is within the authorized warrantee period This warranty does not cover damage caused by accident misuse abuse improper maintenance unauthorized modification or connection to an improper power supply A fee will be charged for repair resulting from such damage This warranty excludes all incidental or consequential damages and any liability other than what is stated above Mobi Technologies Inc 5913 Blackwelder Street Culver City CA 90232 www getmobi com 2013 Mobi Technologies Inc All Rights Reserved V011613
4. ear plugs remove any such device and wait 30 minutes prior to taking a temperature 4 Use an untreated ear if ear drops or other ear medications have been placed in an ear canal 5 With object measurement the current surface temperature of the object is displayed It can be different from its internal temperature especially if the surface is exposed to direct sunlight or unusual or extreme conditions Fever Alert feature If the body temperature reading exceeds 100 4 F FE will flash on the screen to alert you that the reading indicates a fever Depending on how far the reading is above the normal body temperature of 98 6 F you may want to seek medical attention as a high fever can be serious BACKLIGHT FUNCTION Press any button to turn on the backlit LCD Display The backlight will turn off automatically after 5 seconds when in temperature measuring mode Note You can use the LCD Display as a soft glow flashlight so as not to disturb the person whose temperature is being taken while sleeping in a dark area CLEAN TIP ALERT As areminder to clean the probe tip there is a special Clean Tip Alert When you have not used the thermometer for along time or you have taken temper ature readings multiple times the back light will flash for 1minute to remind you to clean the probe tip Also the LCD Display will show the letters CL along with a beeping sound The thermometer will return to original mode af
5. or dead batteries remove the Battery Cover by sliding it toward the bottem end of the thermometer Then pull the old batteries straight up from the compartment and insert new AAA batteries we recommend Alkaline batteries into the battery compartment Make sure you are installing batteries properly matching the positive and negative ends to the corresponding markings inside the battery compartment Slide the Battery Cover back in place so it snaps closed Caution To protect the environment please dispose of any old batteries according to national or local regulations or applicable local ordinances e Keep all batteries out of the reach of children THERMOMETER SPECIFICATIONS Power supply Body measuring range Ear and forehead measure accuracy Object measuring range Object measure accuracy Displayed room temperature range Room temperature accu racy Dimension Weight Forehead operating condition Ear and object operating condition Storage environment DC 3V 2 AAA 32 0 C 42 9 C 89 6 F 109 3 F 0 2 C 0 4 F in range of 35 5 C 42 0 C 95 9 F 107 6 F 0 3 C 0 5 F for other ranges below or above 20 0 C 68 0 F 60 0 C 140 0 F 1 0 C 20 F 5 0 C 59 9 C 41 0 F 139 8 F 1 C 22 F 140 L x33 W x57 D mm 60g without battery 15 0 C 40 0 C 59 0 F 104 0 F with a relative humidity of 20 85 10 0 C 40 0 C 50 0 F 104 0
6. your Ensure you have read the User s Man measuring method is correct ual and know how to use the ther or not mometer properly Assess whether or not you Please keep the thermometer and have allowed the thermometer patient in the measuring room for at and the patient to become sta least 30 minutes as mentioned in this bilized in the room for 30 min manual The measurement is not Are you using the thermometer Always take measurements indoors accurate or there is doubt of indoors or outdoors the measurement results Determine if you might have Set the thermometer down in the held the thermometer in your room where the measurement is hand too long which may to be taken so as to let it stabilize affect its accuracy before use Occasionally check to see if the Immediately replace batteries with Low Battery icon is showing on new ones preferrably Alkaline the LCD screen PROPER DISPOSAL Dispose of the batteries in accordance with current federal state and local regulations As a consumer you may be obligated by law to recycle used batteries e In an environment in which there is electrostatic discharge the unit may malfunction and may require user to reset the unit e Dispose of any electronic device with care floes consult the manufacturer for details LIMITED WARRANTY Mobi Technologies Inc warrants this product to be free from defects in material and workmanship for a period of ninety 90 days from the
7. 96 EC WEEE a al The name and the address of the manufacturer EC REP The name and the address of the authorised representative in the European Community Complies with the European Medical Device 0 1 Q Directive 93142 EEC and amended by directive 2007 47 EC requirements Notified body TUV Rheinland CE0197 O Refer to Instruction Manual TROUBLESHOOTING Checklist Countermeasures No response automatic Batteries low or dead Change to new batteries reset when pulling out Batteries installed in wrong Remove batteries and reinsert plastic insulator tab polarity batteries correctly Poor battery contact Measured temperature is lower Follow steps in User s Manual for than 32 0 C 89 6 F or higher proper measurement Check the than42 9 C 109 3 F operation method These Error Messages indicate Contact Mobi Technologies Inc via a problem with the hardware the contact info at the end of this User s Manual and report which Error Message is being displayed Room or environment Retake measurements within temperature exceeds proper proper operating conditions where operating conditions room temperature is well within the range of 50 F 104 F 10 C 40 C TROUBLESHOOTING cont The measurement is not Check to see if the infrared Clean the infrared sensor with cotton accurate or there is doubt sensor is clean or not swab according to the User s Manual of measurement results Determine whether
8. Ms i 70121 DualScan Ear and Forehead Please Read this Instruction Manual Before Use temperature User s Manual for DualScan Prime Digital Thermometer INTRODUCTION Thank you for purchasing the DualScan Prime Thermometer from Mobi Technologies Inc The thermometer has been carefully developed for accurate safe and fast human body temperature measurements from forehead or ear readings and object temperature measurements to ensure safe temperatures SAFETY PRECAUTIONS Research indicates that the ear is an ideal site for taking body temperature Because body temperature is regulated by the hypothalamus which shares the same blood supply as the tympanic membrane we recommend that you use the ear temperature mode as often as possible However as with any thermometer proper technique is critical to obtaining accurate temperatures Therefore in order to obtain an accurate measurement please read this manual carefully before using e Use of this thermometer is not intended as a substitution for consultation with your physician Measurement results are for reference only Contact your physician if you have or suspect any health concerns e The Infrared sensor must be kept clean dry and undamaged at all times to ensure accurate measurements SAFETY PRECAUTIONS cont e Earwax in the ear canal or lipid on the fore head may cause an inaccurate measurement so make sure the ear canal or forehead is clea
9. by when the thermometer is working If your thermometer will not be used on a regular basis remove batteries to prevent possible damage due to chemical leakage If battery does leak remove carefully e Do not allow bare skin to touch leaking fluid e This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided and this unit can also be affected by portable and mobile RF communications equipment Caution This instrument should not be used adjacent to or stacked with other sensing measuring or medical equipment and if adjacent or stacked use is necessary this machine should be observed to verify that is operating normally for the uses for which it is intended NOTES ON BODY TEMPERATURE Normal body temperature varies A person s normal temperature range tends to decrease with age The following table shows normal temperature ranges by age Normal temperature ranges by age 75 1004 The normal temperature range varies from person to person and can be influenced by many factors such as time of day measuring from different sites level of activity medications emotional condition and more We recommend that you practice with the thermometer on yourself and others when you are healthy This way you know how the thermometer works and can feel more confident of the measurements you take when a family member is ill PACKAGE COMPONENTS DualScan Pri
10. e SETTING TIME AND DATE Press and hold the Settings Button for about 2 seconds to enter into the Settings mode Press the Settings Button again to go to the Time Date format and select 12hr or 24hr mode Note PM will display on screen when in 12hr format Then select Hour Minute Year 2001 2099 Month Day and whether Sleep Mode is ON or OFF When the Sleep Mode is active the thermometer will turn OFF automatically after 1min to 3min depending on the factory default When Sleep Mode is deactivated the thermometer remains with power ON continuously Note For saving battery power we recommend that you set Sleep Mode to ON While in a Settings mode or Format advance through the numbers by pressing the Memory Button as needed To return to normal mode press the Ear and Forehead Buttons at the same time The thermometer will also go back to normal mode automatically after 1 minute of non use SETTING TO CELSIUS OR FAHRENHEIT With the thermometer in Measuring or Memory Mode press and hold the Settings Button to switch between Celsius and Fahrenheit REPLACING THE BATTERIES When the Low Battery Indicator appears on the screen or the thermometer does not function at all you should replace the batteries immediately Note The thermometer is pre loaded with two type AAA batteries so remem ber to remove the plastic tab from the battery connections as shown earlier before initial use To replace low
11. er in your hand as shown here with your thumb or forefinger tip resting lightly on the Ear Button Before you press the button make sure the Infrared Sensor Tip is clean 2 Insert the Ear Probe very gently and slowly into the ear canal Hold the thermometer so that the Infrared Sensor Tip of the Ear Probe faces straight in the direction of the Ear Canal It is important to point the probe tip of the thermometer toward the Eardrum at the end of the Ear Canal inside To do this gently pull the outer earlode toward the rear of the head straightening the Ear Canal for accurate alignment with the Ear Probe Note Always insert the thermometer into the same ear using the same direction and depth 3 Now press and hold the Ear Button and keep the Ear Probe steady until you hear the indicator sound and see the LCD Screen light up indicating your Ear Temperature 9 Measurement The measurement is then complete and the button can be released and the thermometer moved away from the Ear Canal 4 As with the Forehead Temperature read the Ear Temperature on the LCD display in CELSIUS or FAHRENHEIT depending on the mode you set TO MEASURE FOOD OBJECT TEMPERATURE 1 Remove Forehead Probe Cover Hold the ther mometer in your hand as shown with your finger tip on both the Ear Button and Forehead Button Press the buttons simultaneously to enter into the Food Object Mode and the display will indicate this when you see
12. me Thermometer 1 piece 1 5V Battery AAA 2 pieces User manual INTERFACE LAYOUT 1 Forehead Button 2 Food Object Button 3 Ear Button 4 LCD Display Screen 5 Memory Button 6 Settings Button 7 Infrared Sensor Tip 8 Forehead Probe Cover 9 Battery Cover LCD DISPLAY LAYOUT 1 Current Year Display 2 Temperature Display F or C 3 Indicates a Forehead Temperature Measurement 4 Indicates an Ear Temperature Measurement 5 Indicates Object or Food Temperature Measurement 6 Indicates Room Temperature Measurement 7 Low Battery Indicator 8 Memory Indicator AM PM Indicator NOTES BEFORE USE 1 To achieve accurate measurements it is very important to ensure that the infrared sensor is clean before using To clean the sensor gently wipe its surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab After cleaning allow at least 20 minutes drying time before taking temperatures 2 Earwax in the ear canal or moisture on the forehead may cause an inaccurate measurement so make sure the ear canal or forehead is clean If you clean the ear or forehead please wait for 5 to10 minutes before measuring 3 If the temperature of the units storage area differs substantially from that of the measuring room s please wait for the thermometer temperature to adjust to the measuring room temperature for about 30 minutes before measuring 4 Please open the ba
13. n KEEP INFRARED SENSOR CLEAN e If you clean the ear or forehead please wait 5 10 minutes before measuring e Don t touch or blow on the infrared sensor A dirtied infrared sensor may cause inaccuracy e Do not use this thermometer for measure ments other than human body temperature except for the object measurements allowable when in object mode e Avoid measuring the ear temperature if the ear is inflamed or infected The temperature of the unit s storage area may differ from that of the measuring room s temperature so please wait for the thermometer temperature NOT GOOD to adjust to the room temperature about 30 minutes before use Keep the thermometer out of the reach of children e Don t throw batteries into fire Batteries are likely to explode in fire which could pose serious danger e Don t store the thermometer to temperature extremes below 20 C 4 F or over 55 C 131 F or humidity extremes below 10 RH or over 90 RH otherwise it may cause inaccuracy e Don t use the product in a wet ear canal after swimming or bathing It is possible to damage the ear canal e Don t use the thermometer if the main body is damaged for example the infrared sensor is broken The continuous use of a damaged unit may cause injury improper results or other serious danger SAFETY PRECAUTIONS cont e Don t take apart repair or change any parts of the unit at any time e Don t use a mobile phone near
14. ter you press any button and the Clean Tip indicator will stop flashing If no button is pressed within 1 minute the Clean Tip indicator will stop However it will resume again when you press any button subsequently so as to remind you again PREVIOUS READOUTS IN MEMORY The thermometer records and stores a total of nine 9 Memory Readouts of previous Ear and or Forehead temperature measurements The most current measurement is always saved in the last available space Once all nine storage spaces have been occupied with the next reading the oldest stored readout is deleted from memory as the new one is saved To view any of the nine stored readouts pressing the Memory Button once prompts the display to show the number of the last memory readout stored along with the Memory Mode Ag Press the Memory Button repeatedly and you will sequence back through the stored data of that record starting with a Temperature and Type Ear of Forehead of reading then b Time of reading and then c Date of reading Pressing the Memory Button again takes you to the Memory Number previous to the one you ve just observed In this way you can quickly press the button multiple times to go to whatever Memory Number you want and to the Stored Data for each Memory Readout recorded To revert back to the normal mode just press the Ear and Forehead Buttons at the same time or it will go back to normal mode automatically after 1 minut
15. ttery cover and move the plastic insulating tab away when you use the thermometer for the first time and then the ther mometer will turn on automatically as per the LCD display in the left figure Press any button to turn unit on when unit was previously off Start up screen with time displayed TO MEASURE FOREHEAD TEMPERATURE 1 Be sure Forehead Probe Cover is snapped onto the unit before scanning Place the thermometer in your hand as shown here with your thumb tip resting lightly on the Forehead Button Before you press the button make sure the Infrared Sensor Tip is clean 2 Hold the thermometer so that the end of the Forehead Probe Cover is placed flush to skin surface midway between the eyebrow and hairline The tip of the Forehead Probe Cover should gentally touch the skin Now press and hold the Forehead Button to scan the forehead for a temperature measurement 3 Keep the thermometer steady and the button depressed until you hear the indicator sound and see the LCD Display light up indicating your Forehead Temperature Measurement The measurement is then complete and the button can be released and the thermometer moved away from the forehead 4 Read the temperature on the display in CELSIUS or FAHRENHEIT depending on the mode you set r L degrees j _ degrees i CELSIUS FAHRENHEIT TO MEASURE EAR TEMPERATURE 1 For Ear Scans remove Forehead Probe Cover before use Place the thermomet