1. BK PRECISION NO 4030 10 MHz Pulse Generator INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation service and repair of this instrument Before applying power follow the installation instructions and become familiar with the operating instructions for this instrument GROUND THE INSTRUMENT To minimize shock hazard the instrument chassis and cabinet must be connected to an electrical ground This instrument is grounded through the ground conductor of the supplied three conductor ac power cable The power cable must be plugged into an approved three conductor electrical outlet Do not alter the ground connection Without the protective ground connection all accessible conductive parts including control knobs can render an electric shock The power jack and mating plug of the power cable meet IEC safety standards DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard KEEP AWAY FROM LIVE CIRCUITS Instrument covers must not be removed by operating personnel Component replacement and internal adjustments must be made by qualified maintenance personnel Disconnect the power cord before removing the instrument covers and replacing components Under ce
2. adjacent to the power cord receptacle Remove the fuse holder assembly as follows 1 Unplug the power cord from the rear of the instrument 2 Insert a small screwdriver in the fuse holder slot located between fuse holder and receptacle When reinstalling fuse holder be sure that the fuse is installed so that the correct line voltage is selected To verify this check the inscription on the surface of the fuse box At the top left and bottom right corner the line voltage rating is labeled along with a small arrow Pick the line voltage to use and match the arrow on the bottom right corner On the rear panel there is also a label that says LINE VOLT with an arrow Match the line voltage inscription of the fuse box to this arrow to select that line voltage 8 4 Instrument Repair Service Because of the specialized skills and test equipment required for instrument repair and calibration many customers prefer to rely upon B amp K Precision for this service We maintain a network of B amp K Precision authorized service agencies for this purpose To use this service even if the instrument is no longer under warranty follow the instructions given in the Warranty Service Instructions section of this manual There is a nominal charge for instruments out of warranty 15 9 Service Information Warranty Service Please go to the support and service section on our website at www bkprecision com to obtain an RMA Return the product in t
3. arity Normal or Inverted General AC Input 115 230 VAC 50 60 Hz 10 Consumption 10 VA Operating Temperature 32 F to 104 F 0 C to 40 C Humidity 10 80 R H Storage Temperature 4 F to 158 F 20 C to 70 C Storage Humidity 0 90 R H Dimensions W x H x D 10 3 x 4 4 x 12 4 26 2 x 11 2 x 31 5 cm Weight 5 5 lbs 2 5 kg Supplied Accessories Instruction manual power cord BNC to alligator clips NOTE All specifications apply to the unit after a temperature stabilization time of 30 minutes Specifications and information are subject to change without notice To ensure the most current version of this manual please download the current version here http www bkprecision com search manual 4030 For current up to date product information please visit www bkprecision com 12 7 Certification CE Compliant CE Declaration of Conformity The pulse generator meets the requirements of 2006 95 EC Low Voltage Directive and 2004 108 EC Electromagnetic Compatibility Directive Low Voltage Directive EN61010 1 2001 o Safety requirements for electrical equipment for measurement control and laboratory use EMC Directive EN 61000 6 2 2005 EN 61000 6 4 2007 EN 61326 1 2006 o Electrical equipment for measurement control and laboratory use 13 8 Maintenance 81 Preventive Steps Please follow these preventive
4. ay e invertible polarity e Single pulsed output via manual trigger 3 Installation 3 1 Initial Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt The initial physical inspections should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any external damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If damage to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection and contact the distributor from where the instrument was purchased Retain the original packing in case subsequent repackaging for return is required Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included with the instrument are e Power cord e User manual e BNC to alligator clips If the contents are incomplete or if the instrument does not pass the specification acceptance tests notify B amp K Precision 3 2 Input Power Requirements The instrument can operate on 115 or 230 VAC source at 50 or 60 Hz The line selector plug on the rear panel allows you to select the line voltage Before connecting the power plug to an AC line outlet be sure to check that voltage selector plug is set in t
5. entilation holes are not blocked Ensure the ventilation fan is working well It is necessary to inspect the generated signal with an oscilloscope before connecting it to any electronic circuit Hence use of oscilloscope is mentioned in the procedure Turn on the instrument with power on switch provided on the front panel The display LED will light up 1 Select the type of waveform required by adjusting the corresponding knobs by following the steps below 2 Select the type of triggering you require If you want to use standard triggering set the MODE KNOB to INT RATE 3 Connect the main output signal to CH1 of oscilloscope and the SYNC output signal to CH2 of oscilloscope Set the trigger source of oscilloscope to CH2 3 Set the output frequency of the signal with the RATE KNOBS The display shows the output frequency at all times 4 Adjust the output waveform shape by adjusting the WIDTH KNOBS The output of the generator should be reflected on the display of the oscilloscope on CH1 5 Adjust the amplitude of the signal with the LEVEL KNOB 6 Observe the output level changing on the display of the oscilloscopes on CH1 Note Check the impedance of the load before connecting To get an accurate representation of the signal and prevent reflection it is important to match this impedance to the output impedance of the function generator 5 2 Using Manual Trigger In order to use the manual trigger you must have the Rate switch in t
6. entz ee 6 4 Controls and Indicators eene 7 4 1 Front Panel Description ENEE 7 4 2 Rear Panel Description neraneeneneennennennnenneennennennnnnnennennnennnn 8 5 Operating Instructions aiaia eae arae e EE iaa a ai 9 5 1 Pulse Generator Output ENEE 9 5 2 Using Manual Trigger EEN 9 5 3 Using External Trigger 10 6 Specifications un ane ea cheb asa heeled 11 7 CertifiCati OM A A A i i 13 GR ale Ee 14 8 1 Preventivesteps n naeh een 14 82 When the Unit is Not Turning On 14 8 3 E seReplacement sans 15 8 4 Instrument Repair Service nnnenenneeneneeneennennennennennnnnennnnneennnnnenn 15 H Service Information 16 10 Limited One Year Warranty ENEE 17 2 Introduction Description The B amp K Precision model 4030 is specifically designed to include the basic facilities of a Pulse Generator in order to make it an easy to operate unit It offers pulse repetition rates from 0 1 Hz to 10 MHz with rise and fall times of lt 12 nsec pulse width from 50 nsec to 50 msec and pulse amplitude from 0 5 V to 5 V across 50 ohms A provision for external triggering and monopulse generation is also available The x tal mode gives accurate eight spot frequencies derived from a 10 MHz crystal source This manual contains information pertaining to the specifications installation and operation of the model 4030 Pulse Generator Features e Adjustable frequency range from 0 1 Hz to 10 MHz e Four digit LED frequency displ
7. he 10M 100nS position This is the only way to access the manual trigger function If you set the Rate switch to the 10M position and the Width switch to the 50mS and the Mode switch to manual trigger then set the volt division switch on your O Scope to 2V or 5V and your time division respectively at 50mS When you push the manual 9 trigger you will see a 50mS pulse one division horizontally You may have to push it a couple of times because sometimes the trigger pulses off the screen To verify that the pulse is actually triggering you can hook the unit up to a counter that has a Total feature Every time you push the trigger the counter will count 1 pulse If you change your volts division switch to 500mS and leave all the other settings the same as above you will see the pulses very clearly To continue viewing the trigger make sure that the Width switch and the time division switch on your O Scope match There will come a point where the trigger is too fast for your eye to view it using an analog scope If you leave the time division at 500mS or 50mS you will be able to view faster pulses but it will be a very dim and quick dot and you will have to look closely to see it but once again verify the pulse by the counter It should go up 1 every time you push the button 5 3 Using External Trigger First select either portative or negative edge external triggering Then connect your external signal to the TRIG IN BNC on the rear of
8. he correct position corresponding to the line voltage in your location and the fuse rating is as shown in the table Selector Line Voltage Fuse 115V 110 120 V 50 60 Hz 0 5A 230V 220 240 V 50 60 Hz 0 250A Table 1 Fuse Table 4 4 1 Controls and Indicators Front Panel Description 1 2 3 4 5 6 7 8 POWER SWITCH Turns power on and off MANUAL TRIGGER BUTTON Outputs one pulse per button press MODE SWITCH RATE KNOB WIDTH KNOB POLARITY BUTTON Inverts output signal MAIN OUTPUT OUTPUT LEVEL KNOB 9 VARIABLE WIDTH KNOB 10 VARIABLE RATE KNOB 11 DELAY KNOB 12 LED DISPLAY Displays the output frequency 4 2 Rear Panel Description TRIG IN A AC INPUT zeg enea ruse Mi toys 115 210 sone EE 230V 10 50Hz AC INPUT d D SELECTOR SYNC OUT u DISCONNECT BEFORE CHANGING RANGE OR REPLACING FUSE CAUTION FOR CONTINUED PROTECTION AGAINST FIRE REPLACE ONLY WITH FUSE OF THE SELECTED VOLTAGE AND CURRENT RATINGS AC INPUT 13 TRIGGER INPUT 14 SYNC OUTPUT 15 EARTH GROUND SCREW 16 INPUT AC POWER SELECTOR AND FUSE Power input socket and fuse compartment Refer to arrow mark on fuse plug and mark on panel for selected input line voltage 17 ACINPUT VOLTAGE SELECTOR 5 Operating Instructions 5 1 Pulse Generator Output Before applying power to the unit make sure that input voltage is correct and the v
9. he original packaging with proof of purchase to the address below Clearly state on the RMA the performance problem and return any leads probes connectors and accessories that you are using with the device Non Warranty Service Please go to the support and service section on our website at www bkprecision com to obtain an RMA Return the product in the original packaging to the address below Clearly state on the RMA the performance problem and return any leads probes connectors and accessories that you are using with the device Customers not on an open account must include payment in the form of a money order or credit card For the most current repair charges please refer to the service and support section on our website Return all merchandise to B amp K Precision Corp with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North America is included for Warranty Service For overnight shipments and non North American shipping fees please contact B amp K Precision Corp B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 16 10 Limited One Year Warranty B amp K Precision Corp warrants to the original purchaser that its products and the component par
10. l shock hazard disconnect power cord before removing covers Refer servicing to qualified personnel Before connecting the line cord to the AC mains check the rear panel AC line voltage indicator Applying a line voltage other than the indicated voltage can destroy the AC line fuses For continued fire protection replace fuses only with those of the specified voltage and current ratings This product uses components which can be damaged by electro static discharge ESD To avoid damage be sure to follow proper procedures for handling storing and transporting parts and subassemblies which contain ESD sensitive components Compliance Statements Disposal of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This product is subject to Directive 2002 96 EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being put on the market after August 13 san 2005 and should not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposition of this product and otherwise observe all applicable requirements Contents 1 Safety Summary eee aaa aaa aaa aaa aaa aaa aan 1 CN Lie eelere LEE 5 3 Installation tasten RRC 5 3 1 Initial Inspection ENEE 5 3 2 Input Power Reguirem
11. rtain conditions even with the power cable removed dangerous voltages may exist To avoid injuries always disconnect power and discharge circuits before touching them DO NOT SERVICE OR ADJUST ALONE Do not attempt any internal service or adjustment unless another person capable of rendering first aid and resuscitation is present DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT Do not install substitute parts or perform any unauthorized modifications to this instrument Return the instrument to B amp K Precision for service and repair to ensure that safety features are maintained WARNINGS AND CAUTIONS WARNING and CAUTION statements such as the following examples denote a hazard and appear throughout this manual Follow all instructions contained in these statements A WARNING statement calls attention to an operating procedure practice or condition which if not followed correctly could result in injury or death to personnel A CAUTION statement calls attention to an operating procedure practice or condition which if not followed correctly could result in damage to or destruction of parts or the entire product WARNING WARNING CAUTION CAUTION Do not alter the ground connection Without the protective ground connection all accessible conductive parts including control knobs can render an electric shock The power jack and mating plug of the power cable meet IEC safety standards To avoid electrica
12. steps to ensure the proper operation of your instrument e Never place heavy objects on the instrument e Never place a hot soldering iron on or near the instrument e Never insert wires pins or other metal objects into ventilation fan e Never move or pull the instrument with power cord or output lead More importantly never move the instrument when the power cord or output lead is connected e Do not obstruct the ventilation holes in the rear panel as this will increase the internal temperature e Do not operate the instrument with the cover removed unless you are a qualified service technician e Clean and recalibrate the instrument on a regular basis to keep the instrument looking nice and working well e Remove any dirt dust and grime whenever they become noticeable on the outside cover using a soft cloth moistened with a mild cleaning solution 8 2 When the Unit is Not Turning On Check if the power ON OFF switch is turned ON If not then check the power cord Please make sure that the power cord is properly connected to the unit Please also check the main switch and ensure that the AC supply at your site is the same as the one mentioned at the rear chassis of the unit Check for a blown fuse 14 8 3 Fuse Replacement If the fuse blows the LED will not light and the instrument will not operate Replace only with the correct value fuse Refer to Table 1 Fuse Table for fuse values The fuse is located on the rear panel
13. the generator With the RATE KNOB set to 10M 100n the output signal will equal the frequency of the external signal By then selecting the subsequent rates the output frequency will be divide by 10 as you select the decade rates e g if you input a 5 MHz external signal and set the RATE KNOB to 1 M 1 u the output will equal 500 kHz 10 6 Specifications 4030 Frequency Range Internal 0 1 Hz to 10 MHz in 8 decade ranges amp variable adjust Internal Mode Stability 0 5 X tal Spot Frequencies 10 MHz 1 MHz 100 kHz 10 kHz 1 kHz 100 Hz 10 Hz 1 Hz X tal Mode Stability 200 ppm Warm up Time 30 Minutes Triggering Internal 0 1 Hz to 10 MHz External 10 Hz to 10 MHz shal One pulse out for each button press available only for 10 MHz 100 ns rate Ext Trig Input 1 V to 10 Vp p sine amp square Trig Output TTL Pulse Zo 50 ohms Frequency Counter Range 0 1 Hz to 10 MHz Display 4 Digit counter with Internal External and Auxiliary mode Display Accuracy 0 5 1 count Waveform Rate 100 nsec to 0 1 sec 8 decade ranges amp variable adjust Width 50 nsec to 50 msec 6 decade ranges amp variable adjust Delay O to 2 usec variable w r t trigger output 11 Output Pulse Out 0 5 V to 5 V into 50 ohms Impedance 50 ohms Rise amp Fall Time 12 nsec Terminal BNC Pol
14. ts thereof will be free from defects in workmanship and materials for a period of one year from date of purchase B amp K Precision Corp will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form ofa sales receipt To obtain warranty coverage in the U S A this product must be registered by completing a warranty registration form on our website www bkprecision com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed B amp K Precision Corp shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 17 Page intentionally left blank BK PRECISION 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 2014 B amp K Precision Corp Printed in Taiwan v043014