image

Contents

1. warranty is void For further details please contact your distributor 10
2. In no events shall the vendor s liability for direct or indirect special incidental or consequential damages loss of profit loss of business or financial loss which hay be caused by the use of the product exceeds the price paid for the product 2 The vendor makes no warranty or representation expressed or implied with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose 3 The vendor also reserves the right to revise or update the product or documentation without obligation to notify any user of such revisions or updates For further information please contact your vendor 8 Notice 1 All other company or product names mentioned herein are trademarks or registered trademarks of their respective companies Specifications are subject to change without notice Please read user manual carefully before operating the device Please use the power adaptor accompanied with this product Warranty does not cover for damages caused by pairing other power adaptor Please check all connecting devices are properly grounded to avoid electric failure This product has limited warranty for one year from defects in material and workmanship Items that are physically damaged misused tempered with or altered are void of warranty For further details please contact your distributor In case warranty sticker is damaged or missing
3. Monitored PDU Series Switched PDU Series User Manual lt V1 0 gt A www green box com tw www data av com Certifications FCC This equipment has been tested and found to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation CE This equipment is in compliance with the requirements of the following regulations EN 55022 CLASS B RoHS All contents of this package including products packing materials and documentation comply with RoHS A tors FE CE 2009 by Green Box Green Box Technology Co Ltd reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice No part of this document may be reproduced or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of Green Box Technology Co Ltd Contents Le UAUFOGUCTION NGABA KANAN ARNAN AA NGI 1 2 PDU Packaging 2 Si PUNGUO NS AGA ANAN NEA nnmnnn 3 Ca BAN AA iene cnet tscutDieneisutinesiiabigiineinings 4 5 Web Interface naa AA AA 6 6 SPECIFICATION Naa GAL GARA 9 REMAKE NAA AAAAAGAA 10 8 N OEIC Gis nin NANANA NGABA BAKA 10 Monitored and Switched PDU Series 1 Introduction The PDU Power Distribut
4. X 1 means the power on Apply 4 It is nothing to do with the mail setting in the PDU utility 5 Please check the DNS can resolve the server name Monitored and Switched PDU Series E Trap 1 Send the event trap to the specific IP to alert manager Default ID is snmp Password is 1234 2 If you need the PDU utility forward the TRAP and the log to syslog server please input the IP that installed the utility as Receive IP Trap Notification ID Password Receiver IP 192 168 2 114 Update 6 Monitored and Switched PDU Series Specification Interface RJ 45 Ethernet Nominal Input Frequency 50 60Hz Full Range LED Indicator Indicator 1 yellow LED 1 red LED Current Meter 3 digits gt Range OAMP 20AMP True RMS gt Resolution OA 20A 0 1A gt Precision OA 20A 2 0 1AMP Alarm Audible 1 Warning 1 beep in 1 second 2 Overload 3 beeps in 1 second Seven Segment Warning and Overload Meter will flash once in 1 second Operation amp Environment Operating Temperature 0 40 C Relative Humidity 0 90 Storage Temperature 25 65 C Monitored and Switched PDU Series 7 Remarks Please read this operation manual carefully before operating the device To prevent potential power damage do not use 2 wire extension cords Ensure DC outlets at PCs and displays are on the same phase and have correct and common grounding Limited Warranty 1
5. cond Note The audible alarm will not change the beeping status until the current goes down and lower than the setting of warning or overload for 0 5 amps Function Press and release to turn off the warning beeping Button The overload beeping can not be cancelled Press and hold the key after 2 beeping it can let the meter to show up the IP address Press and hold the key after 4 beeping it can change the way to get IP by DHCP or Fixed IP Press and hold the key after 6 beeping it can reset the Ethernet card Note Switched PDU series will reset the power in the same time for pressing and holding the key after 6 beeping 14 Meter Display the current or IP Address 5 LED Current Indicator Light on to indicate the power consumption with the True RMS current meter P Address Light on to indicate the current IP address 6 Output LED LED indicator for output power Support to attach temperature and humidity probe 8 iD o The identification of power bank or PDU Monitored and Switched PDU Series 4 Installation This section will instruct you to quickly install the PDU A g Rack Mount I nstructions Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temp
6. erature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Diagram v PDU Install In the Rack a PDU Install In the Rack oe PDU Install In the Rack as Remote Monitor The multiple PDU power ao PDU Install In the Rack GG PDU Install In the Rack Local Monitor aan PDU Install In the Rack Monitored and Switched PDU Series u Hardware 1 Install mounting brackets The PDU comes with brackets for mounting in a rack To mount the PDU into a rack performs the following procedure Attach the mounting brackets to the unit using the four retainin
7. g screws provided for each of the brackets ll Choose a location for the brackets Ill Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retaining screws Connect input and output power Connect Ethernet cable to the PDU Switch on the PDU Note 1 The default setting for the way to get IP address is DHCP If PDU can not get the IP from DHCP server the IP address will stay at 192 168 0 216 Note 2 TO SETUP THE NETWORK SYSTEM FOR PDU STRONGLY RECOMMAND TO BUILD UP THE POWER MONITORING NETWORK SYSTEM ISOLATED WITH THE OTHERS IN ORDER TO KEEP THE STABILITY OF GETTING POWER INFORMATION AND SYSTEM OPERATION 5 Web Interface m Web Provide a quick checking interface for the status of PDU Index System Information Provide the General Information for the PDU including e Model No e Name e Location e Contact e Version e MAC Status Monitored and Switched PDU Series Model No Name Location Contact Version MAC Temperature Humidity PDU1 PDU2 System Information PDU SH1511 0801 PDU 1 Office Admin 4 02 Jan22008 00 16 18 75 01 0C Status N A N A O CA Normal O 4 Normal Index Network ID Email Trap Note According to different model it indicates the different information Note The following Web pages only support Switched PDU series Control Note According to different model it will display the different co
8. ion Unit is an Internet ready device designed and is equipped with an intelligent current meter True RMS that will indicate the total power consumption of a power strip The PDU offers an easy set up and user friendly communication software This software provides the function that assistant manager to remotely monitor the multiple PDU power consumption to realize the total current power consumption and utilization for the enterprises 1 1 Monitored Features m Built in web server manager can real time to monitoring the current consumption of the power strip m Build in true RMS current meter m Setup easily meter can read the IP address directly m Provides audible alarm when the power consumption over the the setting of warning and overload m Send the email and traps when the power consumption exceed the trigger value of warning or overload to the PDU m Provides utility it can monitor a large mount of PDU at the same time m Supports the SNMP and provide MIB for the PDU to be monitored by NMS m Provides power protection by the circuit breaker m Slim size is suitable for the variety of rack to use 1 2 Switched Features m Built in web server manager can real time to monitoring the current consumption of the power strip m Build in true RMS current meter m Setup easily meter can read the IP address directly Provide audible alarm when the power consumption over the the setting of warning and overload Send the e
9. mail and traps when the power consumption exceed the trigger value of warning or overload to the PDU Provide utility it can monitor a large mount of PDU at the same time Supports the SNMP and provide MIB for the PDU to be monitored by NMS Provides power protection by the circuit breaker Slim size is suitable for the variety of rack to use Real time to control each outlet of PDU Indicate each outlet status with LED Supports the power on sequence Monitored and Switched PDU Series 2 PDU Package The standard PDU package contains a Power Distribution Unit with supporting hardware and software The components of the package are m Power Distribution Unit m Rack mount Brackets m CD ROM it contains User Manual PDU Software MIB Management Information Base for Network MIB mib Adobe Acrobat Reader anda Product Descriptions Monitored PDU A PDU integrated with digital meter it can work stand alone and co operate with Cabinet Monitor to indicate its power consumption Switched PDU An intelligent PDU is not only monitored but also on off controlled through network Monitored and Switched PDU Series 3 Functions E Interface Type A Support 1 PDU with single power bank Type B Support 1 PDU with 2 4 power bank mo Funetions Deseription DD Ethernet The Network connection for the built in web server Audible Warning 1 beep in 1 second Alarm Overload 3 beeps in 1 se
10. ntrol web page Status 1 Indicate the PDU power consumption and status 2 Select the outlet by check box first and click the on or off button to control the PDU power output The default ID is snmp and password is 1234 Load Status Outlet Name Outleta OutletB Outletc OutletD OutletE OutletF OutletG OutletH ID Password Status D CA Normal Status ON ON ON ON ON ON ON ON O0ODODDODDO Control Monitored and Switched PDU Series E Network 1 Provide the network information for Configuration the PDU ID 2 User can change the network acewan setting here IP Address 192 168 0 216 Subnet Mask 255 255 255 0 The default ID is snmp and Gateway 192 168 0254 password is 1234 Primary DNS Server IP 192 168 0 254 DHCP o Update E ID Change ID Password Change the ID and password Original ID The default ID is snmp and password is 1234 Pa Original Password New ID New Password Email 1 When the event occurs PDU Utility Email Notification can send out the email message to the pre defined account Email Server Sender s Email 2 Only support to input email TATA TSA NO v server s domain name Account Name 3 The message in the email Password Indicate OutletA H XXXXXXXX Tama F Recipient s Email status in order X 0 means the power off Email Address