1. TT ula ECOMBI WALL FIXED ELECTRIC STORAGE HEATER ECO158 ECO208 ECO308 ECO408 Please read these ru instructions before installing or using this appliance for the first time IMPORTANT INSTRUCTIONS When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following e WARNING Please read all instructions before installing or using this heater for the first time CURTAIN PIECE OF FURNITURE F min e This heater is hot when in use To avoid 10 burns do not let bare skin touch hot 250 mm surfaces rr e Keep combustible materials such as furniture pillows bedding papers clothes etc and curtains at least a foot 30cm from l l the front sides and rear of the heater 3 3 e It is essential that the indicated minimum qm form clearances are maintained OBJECT e CAUTION Some parts of this product can become very hot and cause burns NAAN Aaaa ANTANI Particular attention must be given where children and vulnerable people are present e Children should be supervised to ensure they do not play with the heater e Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating unattended e This appliance can be used by children aged from 8 years and above and persons with reduced physical sensor
2. RIGHT POSITION _ WRONG POSITION 12 Reconnect the two FAST ON terminals to the aluminum heating element attached to the inner panel at both ends 13 When replacing the exterior front panel align the 2 plastic upper pegs on the heater with the holes in the exterior panel Push the top up into place and push the bottom in until it rests on the plastic feet 14 Replace the front panel with screws RELOCATION A WARNING Relocation to another location must be carried out by an experienced technician If during reinstallation the thermal insulation shows any sign of damage it must be removed and replaced by an identical part MANUALLY RESET TEMPERATURE LIMITER This heater employs a manually reset temperature limiter see LR in the connection diagram This safety device operates when high temperatures are reached at the top of the heater It requires re setting manually Let the heater cool The cause of overheating should be investigated LA wanne Re setting manually must be carried out only by an experienced technician Turn off the heater at the circuit breaker Take off the front panel by removing the two screws located at the bottom Find the limiter LR in the connection diagram and push the small pin until a click is heard 3 OPERATING INSTRUCTIONS A CAUTION DO NOT USE THIS HEATER TO DRY CLOTHES Do not cover this heater at any time CONNECTION DISCONNECTION Power switch All models are equipp
3. ema red dot at the very right part of the display will show that the convector heating element is working at that moment Pressing simultaneously keys and P will display room temperature taken from the sensor at the bottom of the device There can be a temperature difference between this sensor and a normal thermometer set up in a wall room This is because temperature is different at different heights in the room The one at the floor is normally lower User can adjust the sensor so that different thermometers show the same temperature For this you can go to General Settings part and modify the sensor reading according to P5 setting 4 ECOMBI MANUAL MODE This mode will allow ECOMBI to operate the Storage Heater and the Convector together in a combined way The Storage Heater will charge based on the settings of AUTOMATIC STORAGE HEATER MODE and if there is any kind of heat loss in the room and a decrease in the temperature ECOMBI may operate the EMITTER MODE to compensate and balance again the room temperature To select this mode press the key several times until in the display only shows the set up temperature This is without JI IC any preceding letter A or E displayed l e EFEM means that 21 5 C is the system set up temperature default It is possible to adjust the set up temperature by using the keys Jra 5 Temperature value will be changing in increments of 0 5 C When the convector heating element
4. air inlet and outlet grills e A heater has hot and arcing or sparking parts inside Do not use in areas where gasoline paint or flammable vapors or liquids are used or stored e Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons e This guide must be kept and given to any new user SAVE THESE INSTRUCTIONS 2 INSTALLATION INSTRUCTIONS The symbols used in the text are explained below WARNING This indication shows the possibility of causing death from electric shock WARNING This indication shows the possibility of causing death or serious injury CAUTION This indication shows the possibility of causing injury or damage to properties only O gt gt gt Symbol for useful information IMPORTANT Wiring procedures and connections shall be in accordance with the national and local codes having jurisdiction e The warranty of the heater will not cover any damage caused by non observance of any of these instructions e The installation must be carried out in accordance with the current local electrical regulations Any installation or reinstallation has to be carried out by an experienced technician e Please check that the voltage in the rating label fits the power supply e This appliance must be grounded e The appliance should not be installed just below an electrical receptacle e The appliance must be installed i
5. product improvement Elnur reserves the right to alter specifications without notice INSTALLATION INSTRUCTIONS AND USER GUIDE WEB VERSION
6. to prevent them from overturning 6 Connect the heater using the wiring diagram included at the end of this manual Tighten properly the connection block screws Use only silicone insulated cables Do not leave any remaining wire inside the heater WARNING Touching live connections can cause serious personal injury fobs AA a ae gt f z A 7 Disconnect the aluminum heating element by removing the FAST ON terminal on each end of the element A WARNING Steel edges can cut Next unscrew the inner panel and remove it Ml 3 CCTM teres Att tre lt r Ti A CAUTION In the interior part of this inner panel there is a very delicate thermal insulation MICROTHERM panel It has to be handled with extreme care AVOID TOUCHING IT 8 Do not disconnect the electrical heating elements Remove the packing cardboard Lift and tilt the elements outwards being careful not to damage the insulation on the bottom of the heater Aaa LAA M Hf MMM ff iff ily 10 Place the heating elements back into their original position Place the other two rows of storage bricks with the flat side facing out and always on the heating elements supporting tabs I Replace the inner front panel If the bricks have been fitted correctly you will have no difficulty in replacing the panel Make sure the bottom edge of the inner panel is inside the front lip of the heater Please see below
7. up different values for different days in a week please go to General Settings in this manual and change P7 setting to ON position Once it is changed come back to System time setting set hour minutes week s day and validate 0 ECOMBI does not change automatically from summer time to winter time or vice versa Depending on the tariff it may be necessary to change the clock settings to fit these two timings OPERATIONMODES By pressing the key various operation modes may be selected FROST PROTECTION STORAGE HEATER EMITTER ECOMBI MANUAL or ECOMBI AUTOMATIC FROST PROTECTION MODE Lt Lt Lt Li To select this mode press the key several times until the message BEEREESI displayed The set up temperature will be 7 C the appliance will maintain this temperature through convector operation Storage heater will be off in this case 2 STORAGE HEATER MODE arun To select this mode press the key several times until the message E l Ofis displayed AC stands for STORAGE HEATER in Spanish 4 0 would be the charge control position set to position 4 As in a standard storage heater equipped with a 5 position charge control charging settings in ECOMBI go from 0 minimum charge to 5 maximum charge 5 0 charge 100 during all the reduced rate time 4 5 90 4 0 80 3 5 70 3 0 60 2 5 50 2 0 40 1 5 30 1 0 20 0 5 10 0 0 0 o While ECOMBI is charging electric consum
8. 5cm 66cm 89cm I I lcm HEIGHT 73cm 73cm 73cm 73cm DEPTH 18cm 18cm 18cm 18cm WEIGHT 57kg 76kg II ikg 147kg NUM OF BRICKS 7 5kg 8 12 16 NUM OF BRICKS I1 3kg 4 BRICK PACKAGE 11072 11016 11016 11016 Storage heater elements and convector element will never operate at the same time 14 NOTES WARNING In order to avoid overheating do not cover the heater The symbol on the product or in its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product These instructions are only valid in the EU member states 15 ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk Manufactured by ELNUR S A Madrid Spain www elnur global com export elnur global com Management System International Certifications ISO 9001 ISO 14001 As a part of the policy of continuous
9. NNECTION DIAGRAMS Mains switch RI R2 R3 R4 Storage heater heating elements RE Emitter heating element LA Storage heater limit thermostat LE Emitter limit thermostat ECO408 LR Manual Safety Limit K Keyboard ECO308 MB Main Board Cl Power Relay ECO208 ECO158 K R1 R2 R3 R4 o Jo LA AA AHA AH A A GROUND O L RESTRICTED o N SUPPLY O Y YV W U L 24h SUPPLY T S Z S T S a MB O N LE i RE LR 13 TECHNICAL FEATURES Modelo ECOI58 ECO208 ECO308 ECO408 CONNECTION 230 240V 230 240V 230 240V 230 240V CONVECTOR OUTPUT 230 240 450 490W 600 653W 900 980W 200 1307W STORAGE HEATER OUTPUT 230 240 975 1062W 1300 1415W 1950 2123W 2600 283 I VV CHARGE PERIOD 8 7h 8 7h 8 7h 8 7h CHARGING 7 8 kWh 10 4 kWh 15 6 kWh 20 8 kWh INSULATION Class Class Class Class LENGTH 5
10. ed at the right side panel we gain access to the general settings menu PI Starting time of reduced off peak rate electric period P2 Ending time of reduced rate electric period P3 Starting time of the second reduced rate electric period if not available set up 00 00 P4 Ending time of the second reduced rate period if not available set up 00 00 P5 Temperature sensor correction values from 5 C to 5 C P6 Deferred charge ON charge ends at the same time than reduce rate period OFF charge starts at the same time than reduce rate period P7 Weekly programming ON OFF P8 Limit factor of emitter operation mode to increase or reduce the charge Possible values 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 P9 Percentage of automatic charge regulation values 05 10 20 25 PA Excess of temperature protection during the charge Degrees higher than the set up temperature when the charge is interrupted Values 2 3 4 5 Advance with the keys i and k push the key to enter in a parameter Use same keys to modify it To save the new values it is necessary to pass through all of them to the last one PA DEFAULT SETTINGS By pushing the Clock key of the device connected to the mains Software resets to the default settings Four horizontal blinking segments will appear in the screen to confirm it o Incorrect time settings erroneous programming of the reduced rate time and too high temperature settings may result in a high cost of your e
11. ed with a switch on the back side panel It is used to connect and disconnect ECOMBI KEYBOARD Clock key Operation mode key Press tne xey lo aispiay aale Press the key to select different and time Hold it for more than 8 seconds to change values Operalon MOES i FROST PROTECTION AUTOMATIC STORAGE HEATER 1 EMITTER ECOMBI MANUAL ECOMBI AUTOMATIC KEY GG am 11 ier Pea Press the key to decrease different Press the key to increase different values values KEYBOARD LOCK P In any operation mode it is possible to lock the keyboard holding the keys and simultaneously for several seconds When the keyboard is locked if any button is pressed display will show r J and the appliance will not respond To unlock the keyboard hold the keys lt P simultaneously again for several seconds SYSTEM TIME SETTING It is necessary to set the system time for the appliance to follow correct programming and to adjust it correctly to the off peak time periods Off peak periods have to fit with the ones established in GENERAL SETTINGS part as PI P2 P3 and P4 please go to General Settings To set the system time hold the key for 8 seconds The Hour values are changed with the Sane gt ceys Then press the key to save and proceed to change the minutes values Press again to save and proceed to change the week day if weekly programming option is enabled in the GENERAL SETTINGS part If it is necessary to set
12. emoving the heater Turn the carton upside down to allow the heater to stand on its feet and remove the carton Check that it is the correct model and that it is in good conditions Check that all parts have been delivered and are intact 1 Ecombi heater casing 1 bag containing 2 screws and 2 dowels 2 supporting feet This guide ane casing and storage bricks are supplied separately Check the supplied bricks packages correspond to the ones indicated on the heater carton o The heater operation is not affected if bricks with minor damage are used 3 Take off the front panel by removing the two screws located at the bottom Fix the lateral fittings to the metal structure by using the appropriate screws HH MY WH A Mii Sii HT IN ii Wilh 4 Place ECOMBI in your selected installation area Use the heater fixing holes as a template and mark the wall through the fixing holes with a pencil Drill the required holes into the wall Place the dowels and screws into the holes before the appliance installation but do not fasten them tightly 5 Attach ECOMBI to the dowels with the crews IT MUST NOT BE HUNG ON THE SCREWS these are used only to prevent the device from overturning and not to support it If there is any doubt concerning the wall strength consult the corresponding construction specialist The appliances are heavy it is the installer responsibility the correct installation and wall support of these devices
13. equired The set up temperature is independent of the Storage Heater level of charge Default setting for charge is 4 0 This value can be modified by entering into STORAGE HEATER MODE and changing these charging values from 0 to 5 0 WEEKLY PROGRAMMING It is possible to select which days ECOMBI will work and which days it will not By activating P7 in GENERAL SETTINGS this option will be enabled To enter in weekly settings hold the key for 8 seconds Blinking hours will be displayed Press the key then blinking minutes will be displayed Press the key then the first day of the week will blink Change the week day if necessary with the keys and 5 Press the key to save After that it is possible to select which days of the week ECOMBI will follow the selected mode operation or FROST PROTECTION operation An example can be seen here below One or two bars will be blinking for Day One bar stands for FROST PROTECTION permanent mode Two bars stand for SELECTED MODE last mode selected out of the five available Proceed to change the value for day with keys and 5 save with key Proceed to day 2 and so on to day 7 In this example ECOMBI will be operating in normal mode from Monday day to Friday and in FROST PROTECTION mode on Saturday and Sunday 11 GENERAL SETTINGS ECOMBI general operation settings can be modified By pressing the key at the same time as we turn on the heater with the power switch locat
14. is working a small red dot will appear at the very right of the display Ly Lm e CO writ ECOMEBI is charging a small red dot will appear on the left side of the display L Storage Heater and Convector will never work at the same time 5 ECOMBI AUTOMATIC MODE with charge correction In this mode ECOMBI operates in a combined way Storage heater operates during the off peak rate ECOMBI may operate as Emitter providing additional heating to the room if necessary ALSO THERE WILL BE AN AUTOMATIC CHARGE CORRECTION OF THE STORAGE HEATER FOR THE FOLLOWING CHARGING PERIODS 10 rn S E To activate this mode press the ea key several times until the message Mo is displayed A stands for AUTOMATIC mode 21 5 is the set up temperature in C When the Emitter is on a small red dot at the very right of the screen will be displayed Da IC A small red dot next to A will be displayed when storage heater is on HE I J Operation in this mode is similar to the Ecombi Manual Mode but the of the storage heater charge is corrected automatically If working hours of Emitter is higher than a certain value storage heater charge will be increased by a certain On the other hand if Emitter working hours does not exceed this value storage heater charge level is reduced by the same This behavior adapts the consumption to the real thermal needs allowing the maximum level of energy savings at the required comfort r
15. lectricity bill 4 TROUBLESHOOTING Please check it is connected and switched on ECOMBI does not heat Make sure the device is not covered or the lower air inlets are not obstructed The LR safety limit may be activated in this case it is necessary to rearm it manually Please contact technician ECOMBI does not reach set up Make sure that adequate temperature is selected temperature Make sure the heater is sized correctly for heat loss ERR in display Temperature sensor trouble please contact technician If display shows display is blocked Press the and key at the same time for several SeyDoard does NOE respond seconds to unblock it 12 5 MAINTENANCE INSTRUCTIONS Before cleaning make sure the power has been turned off at the circuit breaker panel and that the heating element of the heater is cool Occasionally clean dust with a dry soft cloth Do not use any solvent or abrasive product for cleaning When the Heating season is finished please disconnect the device by turning off the power switch located at the right back of the unit or at the circuit breaker Any other servicing should be performed by an authorized technician 0 ECOMBI has been manufactured under a fully assured quality system and using environmentally friendly processes Once its useful life is finished please take the device to a recycling depot so that its components can be recycled in an appropriate way 6 CO
16. n such a way that it is impossible for anyone using a bath or shower to touch the controls e f during any installation the thermal insulation shows any sign of damage it must be replaced e This heater should be switched off at the circuit breaker before any repair work is carried out This should also be done during times of the year when heat is not required e This appliance is only for permanent connection to a fix installation After installation a survey of the first charging cycle should be carried out to ensure that the main input thermostat switches off Ventilate the room during this first cycle e Never open a charged heater e To maintain stability it is essential that the heater is placed on a level surface and care should be taken to avoid irregular surfaces such as may result from carpets or tiled surrounds partially protruding under the heater e The presence of air particles of smoke dust and other pollutants could in time discolor the walls and surfaces around the heater In order to achieve a correct installation of this device follow these steps Choose the right location to install ECOMBI The minimum clearances must be respected from the appliance to any combustible material such as furniture or curtains To reduce the risk of fire do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater 2 Open the carton at the indicated side and install the supporting feet without r
17. ption a small red dot will appear between the A and the C in the display DEFERRED CHARGING This function in ECOMBI allows optimizing the energy management and consumption If in an off peak period of 8 hours it is only necessary to charge at 50 this is 4 hours this function will make the effective charging period the last 4 hours during the off peak period This means that ECOMBI will be fully charged at the end of the charging period In order to enable disable this option please go to General Settings part in this manual and change P6 setting as ON OFF PROTECTION FOR EXCESS OF TEMPERATURE IN THE ROOM In order to achieve maximum savings and avoid unnecessary energy consumption if during the charging period the temperature in the room exceeds the temperature set up in ECOMBI for that room then the charging will be interrupted until the temperature in the room decreases by 1 C 3 EMITTER MODE This operation mode is used when it is necessary to heat the room temporarily and there is no need for storage heating GC J IG Press the key several times until the message C E l is displayed E stands for EMITTER 21 5 stands for the set up temperature in C Emitter will operate until the temperature in the room reaches 21 5 C then it will maintain the temperature If needed it is possible to change the set point temperature by using the keys J ra 5 Temperature value will be changing in steps of 0 5 C
18. y or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be made by children without supervision e Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance e Children of less than 3 years should be kept away unless continuously supervised e Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a reputable electrician before reusing e Do not use outdoors e To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel e Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater e To prevent a possible fire do not block air intakes or exhaust in any manner e Air inlets and outlets provide proper operation of the appliance and prevent its overheating DO NOT cover
Download Pdf Manuals
Related Search
Related Contents
installatiehandleiding nl/be instructions for installation gb/ie 取扱説明書(PDFファイル) Polycom IP Phone VVX User's Manual Complete Article in PDF - National University of Singapore Manual TR-5800 INSTALLATION INSTRUCTIONS 4. TROUBLESHOOTING List of goods and services suppliers for Conventions and special DCH 230 / DCH 180-SL User`s Manual Copyright © All rights reserved.