Home

user manual - ActiveForever

image

Contents

1. A WARNING A CAUTION CAUTION The device produces enriched oxygen gas which accelerates combustion Do NOT ALLOW SMOKING OR OPEN FLAMES within 10 feet of this device while in use Do not submerse the Inogen One G3 or any of the accessories in liquid Do not expose to water or precipitation Do not operate in exposed rain This could lead to electrical shock and or damage Do not use oil grease or petroleum based products on or near the Inogen One G3 Never leave the Inogen One G3 in an environment which can reach high temperatures such as an unoccupied car in high temperature environments This could damage the device www ActiveForever com 2 Description of the Inogen One G3 Oxygen Concentrator Important Parts of the Inogen One G3 Oxygen Concentrator Display Display Back Breath light Button On Off Detection Light Button i G3 INOGENONE A Ma Flow Control Alert Alarm Audible Alarm Light Button Description of the Inogen One G3 Oxygen Concentrator Chapter 2 3 www ActiveForever com User Controls ON OFF Button Press once to turn ON Press and hold for one second to turn OFF Audible Alarm Button Pressing this button will toggle the Inogen One G3 s breath detection audible alert on and off 1 Default Mode When the Inogen One G3 is powered up the breath detection audible alert is disabled The display s mode indication area will show a bell icon cros
2. After Your Flight e Remember to recharge additional batteries you may have used prior to your next flight Traveling By Bus Train or Boat Contact your carrier to find out about power port availability Battery Operating Instructions Ensure that the battery is in place and charged Disconnect the Inogen One G3 from its power source While the Inogen One G3 is operating on battery power the battery will discharge The display will indicate the estimated remaining percentage or minutes of use www ActiveForever com When the concentrator detects that the battery life is low with less than 10 minutes remaining a low priority alert will sound When the battery is empty the alert will change to a high priority When battery life is low do one of the following e Plug the Inogen One G3 into an AC or DC power source using the AC power supply or DC cable e Replace the battery with a charged battery after turning off the Inogen One G3 by pressing the ON OFF button To remove battery press and hold the battery latch button and slide battery off the concentrator e If the battery is drained charge the battery or remove it from the concentrator If the Inogen One G3 is being powered by the AC power supply or DC power batteries will charge during operation Leaving your Inogen One G3 plugged in past the full charge time will not harm the concentrator or the battery Normal Battery Charging To ensure that your battery
3. DC Input Cable Fuse Replacement The Cigarette Lighter DC power plug contains a fuse If the DC input cable is being used with a known good power source and the unit is not receiving power the fuse may need to be replaced To replace the fuse follow these instructions and refer to the photograph below 1 Remove the tip by unscrewing the retainer Use a tool if necessary 2 Remove the retainer tip and fuse 3 The spring should remain inside the Cigarette Lighter Adapter housing If the spring is removed make sure to replace the spring first before inserting the replacement fuse www ActiveForever com 4 Install a replacement fuse Inogen RP 125 BUSS MDA 12 and reassemble the tip Ensure the retainer ring is properly seated and tightened Si JE ot 1 oa n A n kikit a l Mon LI pi Cigarette Adapter Plug Fuse Retainer Tip Retainer Inogen One G3 Column Change Procedure 1 Turn off the Inogen One G3 concentrator by pressing the power button to shut down the device 2 Remove the Inogen One G3 concentrator from the carry bag 3 Remove the battery from the Inogen One G3 concentrator 4 Turn Inogen One G3 over so that is standing in the upside down position where the display panel is facing down and the bottom of the Inogen One G3 A is facing up me 5 There are two columns metal tubes on the Inogen One G3 concentrator and one is located on each side of the device Clean
4. plug to the power source and connect the power output plug to the ie Inogen One G3 The green LED on the power supply will be illuminated and a beep will sound from the concentrator CAUTION CAUTION CAUTION CAUTION NOTE Ensure the power supply is in a well ventilated location as it relies on air circulation for heat dissipation The power supply may become hot during operation Make sure the power supply cools down before handling The power supply is not water resistant Do not disassemble the power supply This may lead to component failure and or safety risk Do not place anything in the power supply port other than the supplied wall cord Avoid the use of electrical extension cords with the Inogen One G3 If an extension cord must be used use an extension cord that has an Underwriters Laboratory UL Mark and a minimum wire thickness of 18 gauge Do not connect any other devices to the same extension cord Under certain conditions see Technical Specifications the power supply may shut down The green LED will blink or will no longer be illuminated If this occurs disconnect the power supply for at least 10 seconds and reconnect www ActiveForever com 5 Connect the nasal cannula tubing to the nozzle fitting Nozzle fitting is located on the top of the Inogen One G3 Use of a single lumen cannula up to 25 feet in length is recommended to ensure proper breath detection and oxygen delivery Additional tit
5. airlines you will need sufficient battery power for the duration of the flight plus a conservative estimate of unanticipated delays e Arrive at the airport early Airport security screening personnel may require extra time to inspect your Inogen One G3 Operating Instructions Chapter 3 www ActiveForever com 17 18 While waiting to board your flight you may be able to conserve battery power by using the AC Power Supply to power your Inogen One G3 from an electrical outlet in the airport termi nal if available e You should inform the airline you will be using your Inogen One G3 Have your physician letter with you and ready for inspection if requested During Your Flight 1 If using airline power port remove the Battery from the Inogen One G3 Oxygen Concentrator Due to aircraft power limitations the AC Power Supply cannot be used to charge the Inogen One G3 Battery when onboard aircraft 2 Connect the DC Power Plug for available airline power Check with airline personnel to ensure compatibility e During taxi takeoff and landing stow your Inogen One G3 under the seat in front of you Your Inogen One G3 will fit upright under most airline seats However if it doesn t fit you may turn it on its side with vents facing up e It is not necessary to turn off your Inogen One G3 during taxi takeoff and landing if your physician s written statement requires you receive oxygen during these periods
6. alarm More frequent beeps indicate higher priority conditions Input Output Connections Particle Filters z The filters must be in place at the intake end of the concentrator during operation to keep input air clean alt Cannula Nozzle Fitting The nasal cannula connects to this nozzle for Inogen One G3 output of oxygenated air DC Power In Connection for external power from the AC power supply or gt en DC power cable A Jn USB Port Used for servicing only Description of the Inogen One G3 Oxygen Concentrator Chapter 2 5 www ActiveForever com Power Supply Options Single and Double Rechargeable Lithium lon Batteries The battery will power the Inogen One G3 without connection to an external power source When fully charged a single battery will provide up to 4 hours of operation a double battery will provide up to 8 hours of operation The battery recharges when properly installed in the Inogen One G3 and the concentrator is connected to AC or DC power Recharging time is up to 4 hours for a single battery and 8 hours for a double battery See information in the Battery Care and Maintenance section Power Supply Overview The Inogen One G3 AC power supply BA 301 is used to power the Inogen One G3 concentrator from an AC power source Description The Inogen One G3 AC power supply is specifically designed for use with the Inogen One G3 Oxygen Concentrator lIO 300 The AC po
7. internal function Therefore its RF emissions are very low and not likely to cause any interference in nearby equipment RF emissions Class B The Inogen One G3 Oxygen CISPR 11 Concentrator is suitable for use in all Harmonic Emissions Class A establishments including domestic ee pani establishments and those directly Voltage fluctuations Complies connected to the public low voltage flicker emissions power supply network that supplies IEC 61000 3 3 buildings used for domestic purposes Inogen One G3 System Specifications Chapter 8 41 www ActiveForever com 42 Recommended Separation Distances between Portable and Mobile RF Communications Equipment and This Device This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Inogen One G3 Oxygen Concentrator can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and this Inogen One G3 Oxygen Concentrator as recommended below according to the maximum output power of the communications equipment 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz d 1 2VP d 1 2VP d 2 3VP 0 23 sa For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter wh
8. is fully charged Inogen One G3 Backpack Alternative optional way of carrying your Inogen One G3 hands free more comfort out of your way with extra pockets for additional accessories To order please call Inogen Client Services Description of the Inogen One G3 Oxygen Concentrator Chapter 2 www ActiveForever com www ActiveForever com Operating Instructions Exhaust ko General Instructions 1 Place the Inogen One G3 in a well ventilated location Air intake and exhaust must have clear access Locate the Inogen One G3 in such a way that any auditory alarms may be heard Intake 2 Ensure both particle filters are in place 3 Install the battery Insert the Inogen One G3 battery by sliding battery into place until the latch returns to the upper position 11 www ActiveForever com CAUTION The Inogen One G3 battery acts as a secondary power supply in the event of a planned or unexpected loss of the AC or DC external power supply When operating the Inogen One G3 from an AC or DC external power supply a properly inserted Inogen One G3 battery should be maintained in the unit This procedure will ensure uninterrupted operation and will operate all alarms and alerts in the event of a loss of the external power supply 4 Connect the Power Supply Connect the AC input plug to the power supply Connect the AC power
9. is properly charging inspect that the correct AC and DC power output plug adapter is being used and that the adapter is properly inserted into the power outlet Observe the display or lights that indicate charging status Battery Care and Maintenance Your Inogen One G3 Lithium lon Battery requires special care to ensure proper performance and long life Use only Inogen One G3 Batteries with your Inogen One G3 Concentrator Keep Dry Always keep liquids away from batteries If batteries become wet discontinue use immediately and dispose of battery properly Operating Instructions Chapter 3 19 www ActiveForever com 20 Effect of Temperature on Battery Performance The Inogen One G3 single battery powers the Inogen One G3 Concentrator up to 4 hours under most environmental conditions To extend the run time of your battery avoid running in temperatures less than 41 F 5 C or higher than 95 F 35 C for extended periods of time Battery Time Remaining Clock The Inogen One G3 continuously displays battery time remaining This displayed time is only an estimate and the actual time remaining may vary from this value Please Follow These Important Guidelines to Maximize Battery Performance and Life e Store battery in a cool dry place Store with a charge of 40 50 e If using multiple batteries make sure that each battery is labeled 1 2 3 or A B C etc and rotate on a regular basis Batteries should not be left dor
10. patient The Inogen One G3 may be used in home institution vehicle on an airplane and various mobile environments The expected life for the Inogen One G3 Oxygen System is 5 years with the exception of the sieve beds metal columns which have an expected life of 1 year and the batteries which have an expected life of 500 full charge discharge cycles Intended Use Contraindications and General Precautions Chapter 1 1 www ActiveForever com Contraindications CAUTION CAUTION CAUTION ZIN warina This device is NOT INTENDED to be life sustaining or life supporting Under certain circumstances the use of non prescribed oxygen therapy can be hazardous This device should be used only when prescribed by a physician Additional monitoring or attention may be required for patients using this device who are unable to hear or see alarms or communicate discomfort If the patient shows any signs of discomfort a physician should be consulted immediately The Inogen One G3 is not designed or specified to be used in conjunction with a humidifier nebulizer or connected with any other equipment Use of this device with a humidifier nebulizer or connected with any other equipment may impair performance and or damage the equipment Do not modify the Inogen One G3 Concentrator Any modifications performed on the equipment may impair performance or damage equipment and will void your warranty General Precautions WARNING
11. Description of the Inogen One G3 Oxygen Concentrator Chapter 2 www ActiveForever com Inogen One G3 Accessories Nasal Cannula A nasal cannula must be used with the Inogen One G3 to provide oxygen from the concentrator A single lumen cannula up to 25 feet in length is recommended to ensure proper breath detection and oxygen delivery Carry Bag CA 300 The Carry Bag provides a protective cover with a handle and adjustable shoulder strap to enable you to carry the Inogen One G3 The Inogen One G3 can be operated using battery power during transport with the Carry Bag The carry bag is designed so that the Inogen One G3 Concentrator is loaded into the carry bag from the bottom of the bag The expandable zippered bottom is designed with an adjustable zipper for use with a single or double battery and easy access for changing battery The expandable section is not intended for use as a storage compartment www ActiveForever com Inogen One G3 Optional Accessory External Battery Charger BA 303 1 Plug the External Battery Charger AC power supply cord into an electrical outlet 2 Plug the External Battery Charger AC power supply into the battery charger 3 Slide your charger onto the Inogen One G3 Battery by clicking and locking into the charger 4 When the battery is in the correct position a solid red light will indicate that the battery is charging 5 When the green light illuminates the battery
12. activex forever IMPROVING OUTCOMES IMPROVING LIVES INOGENONE USER MANUAL Inogen www ActiveForever com www ActiveForever com Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Chapter 8 ok 0 OUR WwW WwW Contents Intended Use Contraindications and General Precautions Description of the Inogen One G3 Oxygen Concentrator Important Parts of the Inogen One G3 Oxygen Concentrator User Interfaces Input Output Connections Power Supply Options Inogen One G3 Accessories Operating Instructions General Instructions Additional Operating Instructions Battery Operating Instructions Battery Care and Maintenance Inogen One G3 Oxygen Concentrator Audible and Visible Signals including Alarms Troubleshooting Cleaning Care and Maintenance Cannula Replacement Case Cleaning Filter Cleaning and Replacement Inogen One G3 Column Change Procedure Other Service and Maintenance Disposal of Equipment and Accessories Symbols Used on Concentrator and Accessories Inogen One G3 System Specifications www ActiveForever com www ActiveForever com 1 Intended Use Contraindications and General Precautions Intended Use The Inogen One G3 Oxygen Concentrator is used on a prescriptive basis by patients requiring supplemental oxygen It supplies a high concentration of oxygen and is used with a nasal cannula to channel oxygen from the concentrator to the
13. ble issues you may encounter are described in this section Inogen One G3 Oxygen Concentrator Any problem Refer to Chapter 4 Refer to Chapter 4 accompanied by information on concentrator display indicator lights and or audible signals Concentrator does Battery is discharged or Use external power supply or not power on when no battery is present replace battery with one that is On Off button is fully charged pressed AC Power supply is not Check power supply connection and connected properly verify green light is solid DC Cable is not connected Check DC Cable connection at properly the Concentrator and at cigarette lighter or auxiliary DC power source Malfunction Contact your equipment provider Troubleshooting Chapter 5 29 www ActiveForever com 30 Troubleshooting continued No oxygen Concentrator is not powered on Cannula is not connected properly or is kinked or obstructed www ActiveForever com Press On Off button to power concentrator Check cannula and its connection to concentrator nozzle Cleaning Care and Maintenance Cannula Replacement Your nasal cannula should be replaced on a regular basis Consult with your physician and or equipment provider and or cannula manufacturer s instructions for replacement information A single lumen cannula up to 25 feet in length is recommended to ensure proper breath detection and oxygen delivery Case Cleaning You may clean the
14. d latched on concentrator If battery error recurs with same battery stop using the battery and switch to a new battery or remove battery and operate concentrator using external power supply Concentrator is producing oxygen at a slightly low level lt 82 for a period of 10 minutes If condition persists contact your equipment provider Battery has exceeded its charging temperature and charging has stopped The battery will not charge while this alert is present but will begin to charge when the battery temperature returns to the normal operating range If battery charging is desired sooner remove the battery from the concentrator and allow it to cool in an open area for approximately 10 15 minutes Then re insert the battery into the Inogen One G3 If the problem still persists contact your equipment provider Concentrator is producing oxygen but cannot report battery status Replace battery If condition persists contact your equipment provider The concentrator requires servicing at the earliest convenience The concentrator is operating to specification and may continue to be used Contact your equipment provider to arrange for service The concentrator s oxygen sensor has malfunctioned You may continue to use the concentrator If the condition persists contact your equipment provider Audible and Visible Signals Chapter 4 25 www ActiveForever com 26 Medium Priority Alerts The following medium priorit
15. e of the breaths giving the appearance of a missed breath This may be normal as the Inogen One G3 senses and monitors the changes in your breathing pattern The Inogen One G3 will normally sense the next breath and deliver oxygen accordingly A green light will flash each time a breath is detected Make certain that the nasal cannula is properly aligned on your face and you are breathing through your nose General To remove power unplug the input cord from its source i e AC wall outlet DC car cigarette lighter adapter www ActiveForever com Additional Operating Instructions For Use In Home with AC Power For operation of the power supply using an AC power source follow these instructions 1 Connect the AC input to the power supply 2 Connect the AC power plug to the power source and connect the power output plug to the Inogen One G3 The green LED will be illuminated indicating the power supply has input power Traveling with your Inogen One G3 System The Inogen One G3 System makes travel by boat car or train more convenient for oxygen users than ever before Now you get the same quality performance and convenience while on the go that you re used to receiving from your Inogen One G3 at home Here are some useful and important instructions for maximizing performance and convenience when using your Inogen One G3 while traveling You should begin planning for a trip with a checklist of items to
16. er Protected against ingress of solid While Used Outside of Carry Bag objects gt 12 5 mm Degree of Protection to Concentrator IP22 Vertically dripping water shall have Components Against Ingress of Water no harmful effect amp protect against While Used Inside of Carry Bag ingress of solid objects gt 12 5 mm diameter when the enclosure is tilted at an angle up to 15 from its normal position Degree of Protection to Concentrator IPo2 Vertically dripping water shall have Exterior Provided by the Carry Bag no harmful effect when the enclosure is tilted at an angle up to 15 from its normal position Degree of Safety for Application in Not suitable for such application Presence of Anesthetic Gases www ActiveForever com ELECTROMAGNETIC COMPATIBILITY This CE Marked equipment has been tested and found to comply with the EMC limits for the Medical Device Directive 93 42 EEC EN 55011 Class Band EN 60601 1 2 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation Guidance and Manufacturer s Declaration Electromagnetic Emissions The Inogen One G3 Oxygen Concentrator is intended for use in the electromagnetic environment specified below The customer or the user of the Inogen One G3 Oxygen Concentrator should assure that it is used in such an environment RF emissions The Inogen One G3 Oxygen CISPR 11 Concentrator uses RF energy only for its
17. ere P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer www ActiveForever com
18. ing Care and Maintenance Chapter 6 www ActiveForever com 33 Inogen One G3 Column Change Procedure continued 6 Remove column by pressing the latch button Open and unlocked with thumb or finger 7 While holding the button open slide the column metal tube out by gripping the exposed aluminum surface with other hand 8 Remove the column metal tube completely from the Inogen One G3 9 Repeat steps 6 8 to remove the other column metal tube Column metal tube Installation 10 Remove dust caps of new column metal tube Make sure there is no dust or debris where the dust caps were located 34 www ActiveForever com Inogen One G3 Column Change Procedure continued 11 Insert column metal tube into the Inogen One G3 concentrator Do not leave the column exposed it should be inserted into the Inogen One G3 as soon as the dust caps have been removed 12 Push the column metal tube into the device such that the column metal tube is fully seated into the Inogen One G3 concentrator The spring loaded latch button should fully return to the closed position 13 Repeat steps 10 12 to install the other column metal tube 14 Connect the AC power supply cord to the Inogen One G3 and plug the power supply AC cord into an electrical outlet Do Not Power on the Inogen One G3 concentrator 15 Press and hold the light button for 10 seco
19. isplay s mode window a The breath detection audible alarm has been enabled The breath detection audible alarm is disabled This is the default condition Display Text www ActiveForever com Informational Messages The following information displays are not accompanied by any audible feedback or any visual change in the indicator lights Inogen The Inogen logo is displayed at startup Setting X Battery Default display when operating on battery power X HH MM represents the selected flow setting e g Setting 2 HH MM represents the approximate time remaining on the battery charge e g 1 45 Setting X Charging xx Default display when operating on an external power or Battery Full supply and the battery is charging xx represents the percent battery charge e g 86 Setting X Battery xx Default display when the battery is not charging or when the time remaining is not available from the battery Charging xx or Displayed when the concentrator is plugged in and being Battery Full used to charge a battery not being used for oxygen production It is normal to see a fully charged battery read between 95 and 100 when external power is removed This feature maximizes the useful life of the battery Notifications Audible and Visible Signals Chapter 4 23 www ActiveForever com 24 Notifications continued The Inogen One G3 monitors various parameters during operation and u
20. ket Ensure the automobile power socket is clean of cigarette ash and the adapter plug fits properly otherwise overheating may occur Do not use the power supply with a cigarette plug splitter or with an extension cable This may cause overheating of the DC power input cable Do not jump start the automobile with the DC power cable connected This may lead to voltage spikes which could shut down and or damage the DC power input cable When powering the Inogen One G3 in an automobile ensure the vehicle s engine is running first before connecting DC cable into cigarette lighter adapter Operating the device without the engine running may drain the vehicle s battery A change in altitude for example from sea level to mountains may affect total oxygen available to the patient Consult your physician before traveling to higher or lower altitudes to determine if your flow settings should be changed Traveling By Air The FAA allows the Inogen One G3 onboard all U S aircraft here are a few points to make air travel easy Planning Your Flight When flying with the Inogen One G3 you must inform the airline that you will be using your Inogen One G3 onboard the aircraft You must also keep a signed statement from your physician with you that includes www ActiveForever com e Your ability to see hear alarms and appropriately respond When oxygen use is necessary all or a portion of the trip e Maximum flow rate correspo
21. mant for more than 90 days ata time www ActiveForever com Inogen One G3 Oxygen Concentrator Audible and Visible Signals Display Icons The Inogen One G3 display is divided into three areas The upper left corner of the display shows the breath detection alert status The lower left corner indicates power source and battery charge level The right side of the display contains text information such as flow setting battery time remaining and error notifications Power Status Icons These icons are examples of those shown in the display s power status window when the Inogen One G3 is operating on battery power a Battery is empty a Battery has less than 1026 charge remaining This icon flashes a Battery has approximately 40 to 50 charge remaining i battery is full Audible and Visible Signals Chapter 4 21 www ActiveForever com 22 Power Status Icons continued The icons below are examples of those shown when the Inogen One G3 is operating from an external power supply and charging the battery The lightning bolt indicates that an external power supply is connected Battery is charging with charge level between 60 and 70 The battery is fully charged and is charging as necessary to maintain its charge Battery is charging with charge level less than 10 The Inogen One G3 is operating from an external power source with no battery present Mode Icons These are the icons shown in the d
22. nding to the pressure in the cabin under normal operating conditions A new statement will not be necessary each time you fly but the statement should be available during every flight e Some airlines may equip their aircraft with onboard electrical power You may have an opportunity to request a seat with a power port which can be used to power your Inogen One G3 However availability varies by airline type of aircraft and class of service You should check with your airlines for availability and always plan on having sufficient battery power for the duration of your flight plus a conservative estimate of unanticipated delays e Your DC Power Cable is equipped with a commonly used cigarette lighter adapter However aircrafts use different power port configurations and it is difficult to determine which type of power port compatibility your aircraft may supply it s a good idea to purchase an adapter such as Magellan s Em Power Socket Connector Item EA27o Before Your Flight Here are some things to keep in mind the day your flight departs e Ensure your Inogen One G3 is clean in good condition and free from damage or other signs of excessive wear or abuse e Bring enough charged batteries with you to power your Inogen One G3 for the duration of the flight plus a conservative estimate of unanticipated delays e Regional Commuter airlines do not offer onboard electrical power If your travel plans call for flights on regional
23. nds and screen will display sieve reset message Release button once message is displayed on screen INGGENOCHME ap 16 Press the bell button once and screen will display sieve reset successful 17 Press the power button to turn on the Inogen One G3 and use normally Cleaning Care and Maintenance Chapter 6 35 www ActiveForever com 36 Other Service and Maintenance Disposal of Equipment and Accessories Follow your local governing ordinances for disposal and recycling of the Inogen One G3 and accessories If WEEE regulations apply do not dispose of in unsorted municipal waste Within Europe contact the EU Authorized Representative for disposal instructions The battery contains lithium ion cells and should be recycled The battery must not be incinerated Maintenance Items List e Inogen One G3 single battery model BA 300 e Inogen One G3 double battery model BA 316 e Replacement intake particle filters model RP 300 e Output Filter Replacement Kit model RP 107 e Inogen One G3 columns model RP 320 For assistance if needed in setting up using maintaining or to report unexpected operation or events contact your equipment provider or manufacturer www ActiveForever com Symbols Used On Concentrator and Accessories A warning indicates that the personal safety of the patient may be WARNING involved Disregardi
24. ng a warning could result in significant injury A caution indicates that a precaution or service procedure must be CAUTION followed Disregarding a caution could lead to a minor injury or damage to equipment A See User Manual for Instructions U S Federal Regulation Restricts this Device to Sale by Order of Romy Physician May also be applicable in other Countries No Smoking while device is in use No Open Flames Concentrator Do not incinerate Battery Refer to instruction manual booklet Symbols Used on Concentrator and Accessories Chapter 7 www ActiveForever com 37 Keep Dry Indoor or Dry Location Use Only Do Not Get Wet Use No Oil or Grease Do Not Disassemble contact your equipment provider for servicing by authorized personnel Do Not Dispose of In Unsorted Municipal Waste Type BF Applied Part Not Intended for Cardiac Application Class II Device Electrical Safety Agency Certification Logo Complies With Applicable EU Directives Including Medical Device Directive User Interface Label ON OFF Button Display Backlight Button Increase Flow Setting Decrease Flow Setting Audible Alarm Button 38 www ActiveForever com Inogen One G3 System Specifications Inogen One G3 Concentrator LAW H 875in 22 2cm 3 0 in 7 6 cm 7 25 in 18 4 cm With single battery LAW H 875 in 22 2 cm 3 0 in 7 6 cm 8 25 in 21 cm 4 8 pounds 2 2 Kg includes single ba
25. outside case using a cloth dampened with a mild liquid detergent such as Dawn and water Cleaning Care and Maintenance Chapter 6 31 www ActiveForever com 32 Filter Cleaning and Replacement Both particle filters must be cleaned weekly to ensure the ease of air flow Remove filters from the front of the device Clean the particle filters with a mild liquid detergent such as Dawn and water rinse in water and dry before reuse To purchase additional particle filters contact your equipment provider or Inogen Output Filter The output filter is intended to protect the user from inhalation of small particles in the product gas flow The Inogen One G3 includes an output filter conveniently located behind the removable cannula nozzle fitting Inogen requires that this filter be replaced between patients The output filter may be replaced by the equipment provider or by the owner using the Output Filter Replacement Kit RP 107 The Inogen One G3 Concentrator must be cleaned and disinfected as per the above instructions for each new patient No special maintenance needs to be carried out by the patient Your equipment provider performs maintenance operations to assure continued reliable service from your Inogen One G3 The manufacturer s instructions for the preventative maintenance of the devices are defined in the service manual All work must be performed by trained technicians certified by the manufacturer
26. ply or exchange battery then restart unit if necessary by pressing On Off button Battery HOT Battery has exceeded temperature limit while concentrator Shut Down is running on battery power Concentrator has stopped producing oxygen If possible move concentrator to a cooler location then turn power off and back on Ensure airintake and outlet vents have clear access and particle filters are clean If condition persists switch to a backup source of oxygen and contact your equipment provider System HOT Concentrator temperature is too high and oxygen Shut Down production is shutting down Ensure air intake and outlet vents have clear access and particle filters are clean If condition persists switch to a backup source of oxygen and contact your equipment provider Audible and Visible Signals Chapter 4 27 www ActiveForever com 28 High Priority Alerts continued System COLD Shut Down Error Service Needed This may result from the concentrator being stored in a cold environment below o C 32 F Move to a warmer environment to allow the unit to warm up before starting it If condition persists switch to a backup source of oxygen and contact your equipment provider Concentrator has stopped producing oxygen and is shutting down You should 1 Note error number 2 Switch to backup oxygen source 3 Contact your equipment provider www ActiveForever com Troubleshooting Solutions to some possi
27. ration may be needed to ensure proper oxygen delivery when using a particular cannula 6 Turn on your Inogen One G3 by pressing the ON OFF Button A single short beep will sound after the Inogen logo is displayed Please Wait will appear while the concentrator starts up The display will indicate the selected flow setting and power condition Following a brief start up sequence a warm up period up to 2 minutes will initiate During this time period the oxygen concentration is building to but may not have reached specification Additional warm up time may be needed if your Inogen One G3 has been stored in extremely cold temperatures 7 Set the Inogen One G3 Concentrator to the flow rate prescribed by your physician or clinician Use the or setting buttons to adjust the Inogen One G3 to the desired setting The current setting can be viewed on the display Operating Instructions Chapter 3 www ActiveForever com 13 14 8 Position the nasal cannula on your face and breathe through your nose The Inogen One G3 will sense the onset of inhalation and deliver a burst of oxygen at a precise time when you inhale The Inogen One G3 will sense each breath and continue to deliver oxygen in this manner As your breathing rate changes the Inogen One G3 will sense these changes and deliver oxygen only as you need it At times if you inhale very quickly between breaths the Inogen One G3 may ignore on
28. remember This checklist should include Y AC power supply and DC power cable Y Extra Battery s if required Y Important phone numbers such as those of your physician and home healthcare provider or providers in the area you will be traveling v Plan for backup oxygen in the event of a prolonged power outage or mechanical failure For Use In Automobile RV Boat Aircraft For operation using a DC power source follow these instructions 1 Connect the DC power output plug to the Inogen One G3 2 Connect the DC power plug Cigarette Lighter Adapter to the power source 3 The plug should insert into the socket without excessive force and securely remain in place Operating Instructions Chapter 3 15 www ActiveForever com 4 Check the device display screen to confirm that an external power supply is connected An icon of a battery with a lightning bolt or an AC power plug will be displayed on the screen indicating that external power is connected and functioning properly WARNING A 16 WARNING CAUTION CAUTION CAUTION CAUTION CAUTION Ensure that the automobile power socket is adequately fused for the Inogen One G3 power requirements minimum 15 Amp If the power socket cannot support a 15 Amp load the fuse may blow or the socket may be damaged The tip of the Cigarette Adapter Plug becomes HOT when in use Do not touch the tip immediately after removal from an auto cigarette lighter soc
29. sed out with an X in default mode 2 Breath Detection Alert Mode The Inogen One G3 will alert with audible and visual signals for no breath detected when this mode is enabled and no breath has been detected for 60 seconds At 60 seconds the device will enter into auto pulse mode and once another breath is detected the device will exit auto pulse mode and deliver normally on inspiration The display s mode indication area will show a bell icon flashing red light and display message when the alert is enabled 3 If power is lost breath detection alert mode resets to default mode Flow Setting Control Buttons Use the or flow setting control buttons to select the setting as shown on the display There are four settings from 1 to 4 Display Backlight Button Push on automatically turns off after 10 seconds User Interfaces Display This screen displays information regarding flow setting power status battery life and errors If you would like to change the language on the Inogen LCD Screen contact Inogen Client Services INOGENONE www ActiveForever com User Interfaces continued Indicator Lights fa A red light indicates either a change in operating status or a amp condition that may need response alarm A flashing light is higher priority than non flashing Audible Signals An audible signal beep indicates either a change in operating status or a condition that may need response
30. tilizes an intelligent alarm system to indicate a malfunction of the concentrator Mathematical algorithms and time delays are used to reduce the probability of false alarms while still ensuring proper notification of an alarm condition If multiple alarm conditions are detected the highest priority alarm will be displayed The following notification messages are accompanied by a single short beep Inogen One Shutting Down HH MM Vx x Serial Number Low Priority Alerts On Off button has been pressed for two seconds Concentrator is performing system shut down Audible Alarm button has been pressed for five seconds The following low priority alert messages are accompanied by a double beep and a solid red light Battery Low Attach Plug O2 Service Soon Battery power is low with less than 10 minutes remaining Attach external power supply or power down and insert a fully charged battery Column maintenance is required within 30 days Press and hold the light button for 3 seconds to clear message from display The message will be silenced for 72 hours Contact your equipment provider to arrange for service www ActiveForever com Low Priority Alerts continued Check Battery Oxygen Low See Manual Remove Battery to Cool Comm Error See Manual Service Needed O2 Sensor Fail See Manual Battery error has occurred Check the connection of your battery and ensure that it is properly attached an
31. ttery Less than 42dBA as packaged on setting 2 Warm Up Time 2 minutes 90 3 6 at all settings 4 settings 1 to 4 Power AC Power Supply AC Input 100 to 240 VAC 50 to 60 Hz Auto Sensing 1 0A DC Power Cable DC Input 13 5 15 5VDC 10A Max Rechargeable Battery Voltage 12 0 to 16 8 VDC Battery Duration Up to 4 hours with single battery Up to 8 hours with double battery Battery Charging Time Up to 4 hours for a single battery Up to 8 hours for a double battery Environmental Ranges Temperature 41 to 104 F 5 to 40 C Intended for Use Humidity 0 to 95 non condensing Altitude o to 10 000 ft o to 3048 meters Environmental Ranges Temperature 13 to 158 F 25 to 70 C Intended for Storage Humidity 0 to 95 non condensing Store in a dry environment Transportation Keep Dry Handle With Care Inogen One G3 System Specifications Chapter 8 39 www ActiveForever com 40 Inogen One G3 Concentrator continued Tested by Independent Safety IEC 60601 1 Laboratory CAN CSA C22 2 No 60601 1 Electromagnetic Compatibility IEC 60601 1 2 RTCA DO 160 Classifications Mode of Operation Continuous Duty Type of Protection Against Electrical Class Il Shock Degree of Protection to Concentrator Type BF Components Against Electrical Shock Not intended for cardiac application Degree of Protection to Concentrator IP20 Not protected from dripping water Components Against Ingress of Wat
32. wer supply provides the precise current and voltage required to safely power the Inogen One G3 and is designed to operate from specified AC power sources When used with AC power sources the power supply automatically adapts to input voltages from 100V to 240V 50 60HZ permitting use with most power sources throughout the world The AC power supply will charge the Inogen One G3 Batteries when used with AC input power Due to aircraft power limitations the AC Power Supply cannot be used to charge the Inogen One G3 Battery when used on an aircraft The AC power supply is used with the following components e Power supply with attached power output cable to connect to the Inogen One G3 e AC power input cable The DC power cable BA 306 is specifically designed for use with the Inogen One G3 Oxygen Concentrator IO 300 The DC power input cable connects directly to the automobile cigarette lighter or auxiliary DC power supply Refer to Chapter 3 for additional operating instructions for use with DC power source www ActiveForever com Inogen One AC Power Supply Model BA 301 LED Indicator Light AC Input Power Output Plug Plug into Concentrator AC Power A Plug Inogen One G3 DC Power Cable Model BA 306 DC cigarette lighter Power Plug for use in Automobile RV Boat Aircraft V Power Output Plug Plug into Concentrator Actual product appearance may vary
33. y alert messages are accompanied bya triple beep repeated every 25 seconds and a flashing red light No Breath Detect Check Cannula Oxygen Error Service Needed O2 Delivery Error System Error See Manual Battery HOT Warning Concentrator has not detected a breath for 60 seconds Check that cannula is connected to concentrator there are no kinks in tubing and cannula is positioned properly in your nose Oxygen output concentration has been below 50 for 10 minutes If condition persists switch to your backup oxygen source and contact your equipment provider to arrange for service A breath has been recognized but proper oxygen delivery has not been detected Concentrator is experiencing an error but is capable of continued operation Remove and re insert battery and or check external power supply connections If condition persists contact your equipment provider Battery has exceeded temperature limit while concentrator is running on battery power If possible move concentrator to a cooler location or power unit with an external power supply and remove battery If condition persists contact your equipment provider www ActiveForever com High Priority Alerts The following high priority alert messages are accompanied by a five beep pattern repeated every 10 seconds and a flashing red light Battery Empty Concentrator has insufficient battery power to produce Attach Plug oxygen Attach external power sup