Home
AS 488/TM
Contents
1. If necessary the following files in directory A INI should be modified in accordance with the new configuration guidelines AS_KOM IN settings for non redundant operation of the CS 275 bus DP1 IN parameters for pull amp plug diagnosis and ODIS DP2 IN parameters for 2nd DP line L2AMPRO IN parameters for system bus PROFIBUS TM After a successful transfer exit ASBEDIEN with Alt X Now perform the following two steps 1 Initiate a reboot of the AS 488 TM reset or off on 2 Install the new terminal program ASBEDIEN V1 09 or V2 01 to your PC from the diskette IBS tools included with your delivery Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 9 of 22 Product Information May 2003 AS 488 TM M02 03 To check the update procedure start the new ASBEDIEN and select the AS status screen BT STAT In addition to the start up message the system version M01 09 is displayed Note If there is already a version M02 02 on the memory card you can use the files from directory C UPGRADE AS_SW 203 M02 03 instead of the files from C UPGRADE Update_M 109 for the online update additionally to the files from C UPGRADE AS_SW 203 From this results a version M02 03 Attention The data transfer was only successful if the command COPY_TM ends without error messages and without any manual intervention
2. 0 linking to SIMATIC S5 or S7 the bytes of the data words in the DB blocks are reversed compared to the TELEPERM representation With the selection of data type 3 the bytes of the data are reversed by the S5KS block before transmission and the data have the SIMATIC bit significance in the received data block 7 IEEE floating point format new data type 4 Character string new data type 5 If a configuration fault STF 1 appears with data type DAAR 5 FC field both outputs STGA and STGB are set to zero Extended e The receiver block S5KE reads the receiver telegrams and functions and initiates the transfer to the global binary and analog blocks as features of the well as to FC fields S5KE block e The receiver block S5SKE also monitors the coupling e Per invocation the block can handle a maximum of 12 telegrams Further details for configuration may be read in the documen tation Instructions for Configuration of Input Output Modules on the TELEPERM M I O Bus C79000 G8076 C703 file PERPRO_E pdf on the IBS Tools Disk e Byte reversal for binary value transmission as with S5KS see above Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 18 of 22 Product Information May 2003 AS 488 TM M02 03 4 4 2 Notes Restrictions Note for installing the In the AS 488 TM all instances of the S5KS block configured transmitter block with the same BGNR and KNR have to be installed into the S5KS s
3. be the case that despite the battery memory the time on the AS 488 TM is reset to 01 01 94 00 00 00 when turned on Correction offline Start a terminal program e g windows terminal or HyperTerminal on the IBS terminal PC which is connected to the serial port COM1 Settings 19200 Baud no parity 8 data bits 1 stop bit Then call up the BIOS setup press Q and switch on the CPU Set the correct date in the setup menu and save the settings After this has been set once the battery memory will function for the date and the time Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 22 of 22
4. e g termination with ESC In the case of errors the copy procedure must be repeated If problems occur during the data transfer frequent terminations we recommend the following procedure e If the first file IBS_BEDI 386 was transferred without errors the AS can be rebooted with the new emergency utility disk press MRES during switch on Together with the new ASBEDIEN V1 09 or V2 01 an error free transfer can be expected e Before the next RESET the files IBS_BEDI 3886 and STARTER 386 must be successfully transferred 2 3 2 Update by Programming Device PG740 Before starting the UPDATE activities pulling the memory card please ensure that a current backup of the customer s system and any files that are to be modified exists This will allow the previous software version to be restored in the even of unforeseen circumstances Stop your AS running e g with STO and then switch the AS off before pulling the memory card Copy the files listed under 2 3 1 from the upgrade update directories into a new directory having the name of your PG740 For the update insert the memory card into the MEM CARD slot of the PG740 Now copy all files from the directory name onto the memory card either using the file manager or explorer or using a DOS box COPY name E y Now perform the following two steps 1 Plug the upgraded memory card of the AS back into the allocated AS 488 TM and initiate a reboot of the AS 488 TM p
5. software M02 01 i e the modules from the directory M02_00 01 on the diskette Linking PROFIBUS PA to AS x88 TM must no longer be copied on the memory card with M02 03 02 01 or M01 09 08 07 The version V1 00 of the file PA_TREIB NL delivered with this software package can further be used unchanged Order no 6DS5 130 8AA or 8AB Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 12 of 22 Product Information May 2003 AS 488 TM M02 03 3 Removed Errors ZEM M Function concerned Appearance Modification Configuring via bus from PROGRAF AS V3 from PROGRAF AS NT V4 00 or from AS 235 When calling a short STEP or TML module in NEMO this is immediatelly finished with the message Ausgabeende ohne Pr fung end without check With this no changes are possible and also no test mode with STEP is available This error doesn t appear with ASBEDIEN or PROGRAF AS NT V4 01 Login for bus configuration corrected END SEQUENCE in TML modules If a GA cell is used as step counter it doesn t count with whole numbers but for example 0 5 1 5 2 5 the function of the SEQUENCE instruction is not affected by this Processing of the TML instruction END SEQUENCE corrected Writing parameters into GA GB data blocks from the CFC Online Test in PROGRAF AS If elements of a global data block GA GB GM are written within the online test and this data block is defined larger in the CFC
6. the help of the upgrade diskette see chapter 2 2 1 Notes The V 24 serial interfaces of the AS 488 TM and the PCs are non isolated With a distance of more than 10m between the earthable point of the AS and the earthable point of the PC s protective conductor an electrical isolation of the interface has to be planned Further electronic switches for multiplication of the PC s serial interfaces are not suitable for the commissioning terminal because of the interruption of telegrams at any point We recommend the use of the integrated software switch for up to four AS interfaces Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 5 of 22 Product Information May 2003 AS 488 TM MO02 03 2 1 Startup by Commissioning Terminal The extracted IBS tool diskette contains your local tool in the directory ASBEDIEN Install this on your PC to be used for commissioning of the AS 488 TM according to the installation instructions in the document file ASBEDI_E pdf in the directory ASBEDIEN and connect your PC to the serial commissioning interface of your AS 488 TM via a serial interface For operation under Windows 3 1 a PIF file is delivered with the software This contains the following settings run in full screen mode exclusive foreground execution foreground priority very high For operation under Windows 95 the following setting should be specified idle time activity very low no screen saver Alternatively the new NT
7. version can be used see chapter 4 2 Using your Commissioning terminal installed in this manner and the commands of the ASBEDIEN input program you can operate and monitor your AS 488 TM for install and diagnostic like an AS 235 and also access all data on the memory card inserted in the AS 488 TM Read the parameter files which have to be processed to enable parameterization from the memory card into a file on your PC using the command COPY_PC You can modify this file on your PC according to your system configuration using the ASCII editors which can be executed under DOS and then write them back onto your memory card using the ASBEDIEN command COPY_TM Note Before starting the UPGRADE UPDATE activities please ensure that a current backup of the customer s system and any files that are to be modified exists This will allow the previous software version to be restored in the even of unforeseen circumstances The files on the memory card are not write protected so care should be taken when accessing the memory card To back up the files from the memory card to your archive use the ASBEDIEN command COPY_PC 2 1 1 Upgrade Update Data The data for the upgrade update procedure is existing on the upgrade diskette as self extracting exe file For extracting please start the file UPGRADE EXE If the pre adjusted path is kept the following directory structure is created on your PC programming device C UPGRADE Upgr
8. 003 AS 488 TM M02 03 2 2 1 Restoring a Memory Card This restore is necessary if the memory card is no longer bootable on an AS 488 TM if it has been deleted with the SIMATIC Manager for example The procedure corresponds to an upgrade see chapter 2 2 Special features e Attempting to copy the old files from the memory card to the programming device with a faulty empty memory card appears the error message Not ready when reading from drive E Ignore retry error This message has to be acknowledged with i After that the MC will be formatted e Afterwards some INI files have to be copied from the directory C UPGRADE INI to the memory card and modified specifically for the user AS_KOM IN settings for the system bus DP1 IN parameters for the 1st DP thread DP2 IN parameters for the 2nd DP thread L2AMPRO IN parameters for the system bus PROFIBUS TM STARTER IN starting parameters poss enter add ons e Using a CP5412 for the system bus PROFIBUS TM you have to copy the files DOS_CONF DAT and FW5412 from the directory C UPGRADE CP5412 to the memory card instead of the file L2EAMPRO INI If the display of the AS 488 TM serial number 48xxxx in BT STAT is faulty please contact the TELEPERM M hotline phone 49 180 5050 222 Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 8 of 22 Product Information May 2003 AS 488 TM M02 03 2 3 Pr
9. ART and driver blocks Because this function mode is independent from a HW driven restart the short time output of 0 values is done also if the so called ARS jumper on the I O modules is configured to hold Beyond these zero values are output by power failure of triggering the fuses of binary and analog output modules with ARS switch or there racks expansion units Because the zero state cannot be assumed as identically with the so called safe state the user has to plan a subordinate clearance plane for all security relevant signals During configuration of the process it has to be guaranteed that for protection of people and installations a secondary security system exits independent from the control system New restart reaction Up from system software version M02 01 restart and configuring of the TPM 478 has been extended to the effect that with RSOF the output of the TPM 478 process image to the I O modules is enabled not until the first pass of AS cycle 3 With this a bumpless transition without 0 output on the process signal outputs has been made possible for warm restart Note This modified function has to be enabled explicit by GB ORPA 262 1 In the first pass of the AS cycle 3 all wanted starting states within the process image have to be configured With use of XB blocks AP 1 is absolute necessary Caution Requirement for this new function is a TPM 478 module issue 9 resp a TPM 478 1 from issue 1 For the
10. IBUS Its contents specify the AS 488 TM as the host system and the module card IF964 as the DP master The bitmap file AS488TM BMP must be copied into the BITMAPS directory Once COM PROFIBUS is started the Read in type files menu item or the Read in GSD files menu item from within the file menu need be activated only once see also DP_PRO_E pdf Note In the case of COM PROFIBUS these files are already supplied from V3 1 onwards Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 4 of 22 Product Information May 2003 AS 488 TM M02 03 2 Commissioning The Memory Card contains the entire system software for AS 488 TM It responds with the version ID M02 03 To perform an upgrade or update from diskette an AS 488 TM memory card must be available The upgrade procedure is performed offline with a PC or a programming device having a compatible MC interface e g PG740 The update procedure is performed either from the IBS terminal online or from a programming device having a compatible MC interface e g PG740 A description of the upgrade procedure is provided under heading 2 2 in this document of the update procedure under heading 2 3 Caution The file RM3_PC1 SYS on the memory card must never be deleted or overwritten as this would mean that the memory card would no longer be bootable If this happens nevertheless the memory card can be restored on a programming device with
11. SIEMENS Program Library Karlsruhe A5E00228862A Product Information AS 488 TM Var M02 03 Issue May 2003 Descriptors TELEPERM M AS 488 TM Software variant M UPGRADE UPDATE Summary The present Product Information relates to the System Software Package AS 488 TM M 02 03 6DS2 410 0XX00 0XA0 6DS2 410 0XX00 0XBO AS 488 TM M 02 03 6DS2 410 0XX00 0XC2 upgrade update 01 09 Description Erg nzende Systemdoku AS 488 TM German C79000 G8000 C700 Supplem System Docu AS 488 TM English C79000 G8076 C700 This manuals have to be ordered seperate if required SIEMENS AG 1996 2003 Anderungen vorbehalten Subject to alteration Sous r serve de modications Con riserva di modifiche Product Information May 2003 AS 488 TM MO02 03 1 Scope The product information for the system software M02 02 M01 08 remains valid The following information represents a supplement The delivery consists of 6DS2 410 0XX00 0XA0 6DS2 410 0XX00 0XC2 6DS2 410 0XX00 0XBO Upgrade Update AS 488 TM Memory Card Diskette 3 5 with AS 488 TM software Diskette 3 5 with tools for Diskette 3 5 with tools for installation installation Diskette 3 5 with software for Diskette 3 5 with software for Bus Operating Console Bus Operating Console Software contract and Software contract registration card Product Information Product Information Note on software protection The memory card must be considered as part
12. TPM 478 exists an upgrade package order no 6DS9 630 8AA Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 20 of 22 Product Information May 2003 AS 488 TM MO02 03 6 Limited Operating Performance No safety relevant software faults are currently known the known faults are assigned to fault class 3 and lower Caution When working on initialization files INI tabs 09H should not be used Spaces 20H should be used instead Failure to comply could lead to interpretation errors AS 488 TM with TELEPERM M I Os The limitations with respect to use of TM I Os module types all TM modules listed in the AS388 TM and AS488 TM supplementary system documentation C79000 G8076 C700 or at catalogue PLT 112 and official notes in TELEPERM M aktuell can be used Errors failures faults of the I O buses are not displayed by LEDs on the TPM 478 these can be recognized e g by failure signals of the drivers The module 6DS1607 operates with compatible functions but the pulses which have been accumulated in the previous cycle are always output when reading The dead time is reduced if a faster TPM 478 cycle is configured Operation of the coupling modules 6DS1318 8AB and 6DS1333 8AB as well as CP581 TM as far as compatible to S5Kx driver When using the firmware TPM 478 IO part version 2 Fixed memory package S79300 G196 A900 1 position S79300 G196 A903 2 2 position S79300 G196 A904 2 only tele
13. ade batch C UPGRADE AS_SW 203 AS system software M02 03 C UPGRADE CP5412 Files for operating the system bus with CP5412 C UPGRADE INI Initialization files for restoring C UPGRADE RMOS32 Programs for formatting procedure C UPGRADE Update_M 109 Data for update to M01 09 If a different path as C has been selected while extracting the environment variable UP_DRIVE has to be changed in UPGRADE BAT Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 6 of 22 Product Information May 2003 AS 488 TM MO02 03 2 2 Procedure for Upgrade to M02 03 with Programming Device PG740 Stop your AS running e g with STO and then switch the AS off before pulling the memory card For the upgrade insert the memory card into the MEM CARD slot of the PG740 Now start the batch UPGRADE BAT if applicable information on the memory card drive default setting is E resp the corresponding link Syntax UPGRADE or UPGRADE E This batch file creates a directory C UPGRADE 203 for this at least 2 to 8 MB must be free on drive C depending on the size of the user software copies all files from memory card into the directory C UPGRADE 203 deletes the RMOS system file as this must never be copied to the MC deletes all BAK files copies the files from directory C UPGRADE AS SW 203 into the directory C UPGRADE 203 the system files to be upgraded are then overwritten copies the file STARTER INI from the d
14. ame cycle The reason for this is that all S5KS blocks per module and channel use a common transmit buffer If S5KS from different cycles for example access this buffer transmit data may be deleted or distorted Restriction The new data types 3 5 are only valid for AD telegrams from AS 488 TM to a partner device and for ED telegrams to or their reply from the partner device Telegrams of type AD sent from the partner device to AS 488 TM with data types 3 4 5 cannot be processed with the interface modules 6DS1333 8AB current release 6 and 6DS1318 8AB release 5 In such cases please ask the hotline development for module release or possible update kits Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 19 of 22 Product Information May 2003 AS 488 TM MO02 03 5 Extended Documentation 5 1 Restart of AS 488 TM with Interface Module TPM 478 With each restart of the AS 488 TM the interface module TPM 478 will be parameterized new This happens with Power on Boot by MRES key switch RSOF by operation or key switch Loading LA name or LA name Loading via bus LAB or LABR LOES During this parameterization the SYST WART configuration is passed to the TPM 478 module and a restart of the TPM 478 is activated Consequently the process image of the TPM 478 is rebuild starting from a zero state Therefore 0 values are output to the I O modules as long as the assigned process image is set by REST
15. device e g SIMATIC S5 S7 DAAR or byte 10 0 binary value 1 fixed point number 16 bit 2 S5 floating point number 32 bit 3 binary value with byte reverse per word 4 7 IEEE floating point number 32 bit 5 character string GAGB or byte 5 GB block no 0 254 GA block no 0 254 GA block no 0 254 GA block no 0 254 GA block no 0 254 FC block no 0 254 ANZ or byte 7 8 number of words double words ANZ byte 7 8 1 64 words 16 values word ANZ byte 7 8 1 64 words 1 value word ANZ 1 32 values byte 7 8 2 4 64 words 1 value 2 words ANZ byte 7 8 1 64 words 16 values word ANZ 1 32 values byte 7 8 2 4 64 words 1 value 2 words ANZ byte 7 8 1 64 words 2 values word Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 17 of 22 Product Information May 2003 AS 488 TM M02 03 Extended e While the input FSE 1 is active a telegram is written to the functions and transmitter buffer during every cycle if there is enough space in features of the the transmitter buffer S5KS block Single transmission The input FSE can be reset after the block cycle Messages on the success of the transmission can sometimes only be shown if the S5KS block operates cyclically Byte reversal for binary value transmission new data type 3 With data type
16. e same PC as only then the TMSS communication service is installed The INI file and the documentation BUS_BEDI_E PDF from V2 10 are still valid for V2 11 without change Attention If the previous version of the bus operating console is used on a PC with installed TMSS communication service this service and also BUS_BEDI_E will be disturbed when working with BUS _BEDI_E V2 10 so that the service has to be stopped and restarted after BUS BEDI E was finished gt Use only the new version 2 11 on PC with TMSS Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 16 of 22 Product Information May 2003 AS 488 TM MO02 03 4 4 Extensions at SSKS S5KE Drivers for 6DS1333 8AB 6DS1318 8AB From M02 03 following extended functions are released for the SSKS and S5KE drivers when working with the interface modules 6DS1333 8AB and 6DS1318 8AB Optimization of processing for data type 2 S5 floating point numbers New data type 3 byte reversion New data type 4 S7 IEEE floating point numbers New datatype 5 character string 4 4 1 Summary of the data types The table below shows a summary of the data types and the allowed values for parameters depending on data type and mode for S5KS S5KE from version M02 03 The parameters shown by name are valid for S5KS for pure receiving telegrams the byte no within the telegram is given additionally The contents has to be configured corres pondingly in the connected
17. eceived by the AS 488 TM With not redundant CS 275 the interpretation above PASSIV or STOER applies for bus B as well Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 14 of 22 Product Information May 2003 AS 488 TM MO02 03 4 Extended Functions 4 1 General Extensions F A E Function concerned Appearance Extension SYST WART Programmkopie verwalten Managing a program copy Up from M02 01 M01 07 the previous activated copy is activated again after RSOF and also displayed like this within the SYST WART function Managing a program copy But for being able to cancel a faulty copy now the original is activated after RSOF warm restart and this state is also displayed in SYST WART correctly Reset reaction of the TELEPERM M I O peripherals Up to now the TPM 478 I O interface module keeps the TM I O modules in the current I O state also during STOP state of the AS 488 TM In all operating states in which the AS 488 TM detects and sets the STOP state e g after pulling the memory card a reset signal will be given now to the TM I O peripherals Dependent on the ARS jumper on special I O modules their outputs will then be set to the initial state 4 2 DPCH Channel Diagnosis for ET200M The complex handling with trouble indication for ET200M in AS 488 TM has been simplified by a new driver block DPCH and extended by an open circuit indication The DP driver block DPCH records the d
18. epted Your parameter settings are accepted using the parameterization input P 9 1 and the blocks are stored in the user memory of your AS The activation procedure can be previously aborted using P 11 1 The reloaded file is then no longer present in your AS However you can carry out the installation procedure from the beginning If you already have installed DP driver blocks and you want to update your system software you have to update the algorithm of the DP driver blocks After successful activation the user structure and the driver blocks must be re archived to the memory card otherwise they will be lost during the next boot procedure Notes Subsequent installation of DP_TREIB NL is not necessary when upgrading updating M01 08 resp M02 02 to M02 03 M01 09 The data structures of the DP driver for CP581TM in AS230 235 and AS 488 TM are identically but the program algorithms have to be exchanged With transfering of old user structures to AS 488 TM following steps have to be done Install matching driver programs BT DP see above Input again the parameters BGNR and BADR in all block instancies even if there value doesn t change the check has to be run through Note DPAE driver and analogue input modules with NAMUR range of values for wire breakage The DPAE driver does not know the NAMUR range of values for wire breakage e g AE module 6ES7 331 7RDO However with correct configuration the AE m
19. for a longer time the reaction time for operations becomes larger Internal processing corrected m ASBEDIEN and ASBEDIEN NT AR_PC An already existing target file will be overwritten without checkback Question Yes No before overwriting zom Operation via bus blocked by PBT key switch In ASBEDIEN the function of the PBT process communication keyboard authori zation key switch is simulated by the SCHLn command i e with this the local operating console can be locked But in contrast to AS 230 235 this operating lock affects at AS 488 TM also some operations via the bus configuring console DI AR LA DEL and FORM M This PBT operating lock now applies only to the local operating console but no longer to the configuration via system bus Preah 3 1 General Note Within the state view BT STAT the state of bus A and bus B is shown for the system bus CS 275 or PROFIBUS TM With redundant CS 275 bus this state corresponds to the state of redundancy the state values AKTIV active PASSIV passive or STOER fault may appear at both busses With not redundant CS 275 bus or with PROFIBUS TM the bus B can never take the state AKTIV but only PASSIV or STOER both state values show that bus B is not existing If the AS 488 TM at system bus PROFIBUS TM is coupled to the CS 275 bus via a Bridge CS L2 the bus state values within the state view represent the bus state of the CS 275 bus aS soon as a redundancy message has been r
20. grams with a maximum of 32 data words may be configured Longer telegrams should be split into two shorter ones From module version 6 onwards firmware version 3 is used which allows a maximum of 64 data words to be configured AS 488 TM with PROFIBUS DP I Os The process image length per slave station via PROFIBUS DP is limited by the IF964 DP to 122 bytes It is thus possible to operate up to 7 analog modules with 8 channels each in one slave station New modules can only be released for operation on the AS 488 TM by publishing them in the PLT 112 Catalog or as an addendum to TELEPERM M aktuell When configuring ET200 I O modules using COM ET200M the value for the internal monitoring time is calculated too low by the tool The result may be that I O modules are not recognized removed from COM PROFIBUS V3 0 Remedy Increase the value calculated by COM ET200M by a factor of 2 Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 21 of 22 Product Information May 2003 AS 488 TM MO02 03 Further information The arithmetic accuracy of the AS 488 TM with floating point numbers is higher than that of the AS 235 There may therefore be small deviations in the last digits of the mantissa in the case of calculated analog values or floating point constants in TML The CD coupling is not implemented in the AS 488 TM Any attempt to register a CD coupling from OS or AS 235 will be rejected Remedy When importing str
21. iagnostic messages of channel faults for max 8 channels of an ET200M module at the DP thread of AS 488 TM and displays them at its output bar With that both a group bit and a byte with channel specific faults diagnostic byte are shown for each channel The DPCH block is part of the system software i e it has not to be reloaded via the file DP_TREIB NL The detailed block description is included in the user documentation DP_BST_E pdf within the DOCU directory at the IBS Tools Disk Note Please notice also chapter 1 2 of this product information Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 15 of 22 Product Information May 2003 AS 488 TM MO02 03 4 3 Bus Operating Console BUS_BEDI_E V2 11 Since version M02 02 the bus operating console with the new functions colored picture transmission and PBT process operating console function keys is delivered as replacement for a local operating console with screen configuration and process operating keyboard version 2 10 The programm for the bus operating console is delivered as self extracting file on a separate diskette in case no PROGRAF AS NT is available Installation A directory BUS_BEDI is extracted by starting the file BUSBEDI EXE From this you have to use the files BUS BEDI_E EXE and BUS _BEDI INI The installation and configuration procedure user specific settings in the BUS _BEDI INI file is decribed in the user manual BUS_BEDI_E PDF in deta
22. il From some users came the demand that several applications should be able to access the bus interface simultaneously e g PROGRAF AS NT and PCS 7 TM OS With this the process can be monitored with WinCC as well as values within the AS can be changed in the CFC online test at the same time from one PC This is possible now if version 4 02 of PROGRAF AS NT and version 3 0 of PCS 7 TM OS are used Both applications use the communication service TMSS which does writing and reading the bus interface via the NAT NPCI driver resp SIMATIC NET and distributes the data to the registered applications The installation of this TMSS service is described detailed in the document TM_Server_en pdf within the DOK directory on the CDs of PCS 7 TM OS and PROGRAF AS NT The new version 2 11 of the bus operating console delivered with AS 488 TM M02 03 works also with the TMSS communication service and can therefore be used parallel to the both other applications also several times Note As the installation programm for the TMSS communication service can no longer be delivered on disk the disk Busbedienplatz Bus Operating Console furthermore contains the previous version 2 10 in the BUS BEDI directory which still accesses the driver directly In the BUS_BEDI TMS directory there is the new version 2 11 which can only be used if already a software package PCS 7 TM OS V3 0 or PROGRAF AS NT V4 02 has been installed on th
23. irectory C UPGRADE INI if this no longer exists reformats the memory card and sets up the RMOS system copies all files from the directory C UPGRADE 203 to the memory card Now perform the following two steps 1 Put the upgraded memory card in the allocated AS 488 TM and initiate a reboot of the AS power on 2 Install the new terminal program ASBEDIEN V1 09 or V2 01 to your PC from the diskette IBS tools included with your delivery To check the update procedure start the new ASBEDIEN and select the AS status screen BT STAT In addition to the start up message the system version M02 03 is displayed Notes Subdirectories on the Memory Card will not be copied These have to be saved to PC Programming device bevor starting the upgrade procedure The directory C UPGRADE 203 is not deleted This means that if an error should occur during the upgrade process the process can be repeated Attention If more than one AS 488 TM memory cards are upgraded the directory must either be deleted or renamed between the individual upgrade processes The directory can also be used as a backup copy of the entire AS software system and user software This means that repairs can be carried out on memory cards with defective software create directory UPGRADE 203 copy backed up file to it and start the batch file Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 7 of 22 Product Information May 2
24. is blocks already are existing in the AS the existing type numbers were accepted Your parameter settings are accepted using the parameterization input P 5 1 and the blocks are stored in the user memory of your AS The activation procedure can be previously aborted using P 7 1 The reloaded file is then no longer present in your AS However you can carry out the installation procedure from the beginning After successful activation the user structure and the driver blocks must be re archived to the memory card otherwise they will be lost during the next boot procedure Notes Subsequent installation of IP262 NL is not necessary when upgrading updating M01 08 resp M02 02 to M02 03 M01 09 Up from M02 01 M01 07 a RESTART block REST IP is created during unpacking the IP262 driver blocks RIP KRIP This causes the decompilation in PROGRAF AS to be cancelled with the error message Illegal character in module name REST IP Remedy Rename the block REST IP with SYST WART to REST IP Corrected in PROGRAF AS NT from version V4 01 01 2 6 Extension Software Packages for AS 488 TM PLC PLC Link The version V2 00 of PROFIBUS PLC PLC can further be used unchanged order no 6DS5 124 1AA SIWA block The version V1 02 of the driver for SIWAREX M can further be used unchanged order no 6DS5 470 1AD PROFIBUS PA Link The special version M02 00 01 delivered with this software package has been included in the standard system
25. ocedure for Update M01 08 resp M01 07 06 05 04 to M01 09 2 3 1 Update by Commissioning Terminal You will find the files needed for an update on the UPGRADE UPDATE diskette too Please copy all files from the directory C UPGRADE AS_SW 203 without sub directory M02 03 and from the directory C UPGRADE UPDATE_M 109 to the directory C ASBEDIEN on your Commissioning Terminal PC or into the current working directory e g C TEMP is specified in ASBEDIEN PIF On the Commissioning Terminal PC connected to the AS 488 TM start the program ASBEDIEN exe via ASBEDIEN PIF under Windows 3 11 so that the program runs in full screen mode and without a screen saver Now in command mode copy the files previously backed up to the PC to the memory card in the AS in the following sequence lt Esc gt COPY_TM IBS_BEDI 386 resp lt escsCOPY_TM C ASBEDIEN IBS_BEDI 386 lt Esc gt COPY_TM STARTER 386 resp lt esceCOPY_TM C TEMP STARTER 386 lt Esc gt COPY_ TM BEDIEN 386 lt Esco gt COPY_TM BUSTASK 386 lt Esc gt COPY_TM EBATASK 386 lt Esc gt COPY_TM LA _AR 386 lt Esc gt COPY_TM EMULATOR EXE lt Esc gt COPY_TM FUNC EXE lt Esc gt COPY_TM C_EAM EXE lt ESC gt COPY_TM AR_DG EXE lt Esc gt COPY_TM RMOS IN lt Esco gt COPY_TM M7_235AR SYS lt Esco gt COPY_TM VERSION TXT lt Esc gt COPY_TM DP_TREIB NL lt Esco gt COPY_TM IP262 NL lt Esc gt COPY_TM FENS NL lt Esc gt COPY_TM NAS_DIAG NL
26. odules can be made to return the S7 standard value 7FFF hex if a wire does actually break this is then interpreted by the DPAE driver as a wire breakage in order to do this the release of the wire breakage diagnosis should be parameterised using COM PROFIBUS further information can be found in the S7 manual Ex peripheral modules which can be ordered quoting reference no C7900 G7076 C150 Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 11 of 22 Product Information May 2003 AS 488 TM MO02 03 2 5 Installation of the Reloadable IP262 Driver Blocks RIP KRIP In addition to the execution system and the standard blocks of the AS 488 TM your memory card contains a so called reloadable file with the optimized driver blocks for the controller module IP262 These blocks are not present in the system data area of the AS and are thus not activated automatically You can load these blocks into your user memory and activate them To do this install your Commissioning terminal and transfer the blocks from your memory card to the user memory of your AS using the ASBEDIEN command LA IP262 NL The loaded blocks must then be parameterized to the type numbers provided in their application and activated You activate the parameter settings in the AS input mode using the input instruction BT IP Set the desired type numbers of the driver blocks in the parameterization display using the parameters 1 und 3 If th
27. of the CPU If the memory card is removed during current operation and if the AS 488 TM enters STOP as a result of the software protection all modifications to the configuration are lost which have been made in the meantime and which have not been saved as well as all modified inputs which have been made since the last save operation I O modules may be reset to the basic status Note to the Diskette IBS Tools Hinweise Commissioning Tools Notes Because of space the data on the IBS tool diskette is existing now as a self extracting exe file For extracting please start the file IBS_DISK EXE With this the following directory structure is created on your PC programming device IBS_DISK M2 ASBEDIEN ASBEDIEN V1 09 IBS_DISK M2 ASBEDIEN NT ASBEDIEN V2 01 for Windows NT IBS_DISK M2 DOCU Supplementary Documentation see chapter 1 1 IBS_DISK M2 DOKU Supplementary Documentation in German IBS DISK M2 PROD_INF this Product Information IBS_DISK M2 PROGRAF AS system file for PROGRAF AS see chapter 1 2 Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 2 of 22 Product Information May 2003 AS 488 TM M02 03 1 1 Supplementary Documentation In addition to the tools required for startup of your AS 488 TM the commissioning diskette contains all current information which may help you configuring your AS 488 TM This information which may be useful when starting up is found in this product informati
28. on and in the following files DIODEF_E pdf Description of the pin allocations for the DIO interface module for cabinet status signals such as door contact fan etc BUSINI_E pdf Configuration for operating your AS 488 TM on the CS 275 or PROFIBUS TM system bus PERPRO_E pdf Configuring the Teleperm M I O peripherals new Notes for 6 DS1333 DP_PRO_E pdf Configuring the PROFIBUS DP peripheral The INI files that need modifying for the parameter settings can be found on the AS 488 TM memory card or the upgrade update diskette ASBEDI E pdf User description for the Commissioning Terminal IBS terminal in ASBEDIEN or ASBEDIEN NT directory DP_BST_E pdf Description of the standard DP driver blocks IP262_E pdf Description of the standard driver blocks for IP262 Please print out these document files and add them to your AS 488 TM documents Failure to observe the information provided can result in a serious malfunction of the installation If you do not have the corresponding Windows installation on your PC your local Siemens representative will be pleased to help you Copyright SIEMENS AG 1996 2003 All Rights Reserved A5E00228862A Page 3 of 22 Product Information May 2003 AS 488 TM MO02 03 1 2 AS System File for PROGRAF AS Your commisioning diskette contains a directory PROGRAF after extracting This contains the system file AS SYS required for PROGRAF AS Copy the file AS SYS into your PROGRAF PC into the directory dr
29. ower on 2 Install the new terminal program ASBEDIEN V1 09 to your PC from the second diskette IBS tools included with your delivery To check the update procedure start the new ASBEDIEN and select the AS status screen BT STAT In addition to the start up message the system version M01 09 is displayed Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 10 of 22 Product Information May 2003 AS 488 TM MO02 03 2 4 Installation of the Reloadable DP Driver Blocks DPAE DPAA DPBE DPBA In addition to the execution system and the standard blocks of the AS 488 TM your memory card contains a so called reloadable file with the optimized driver blocks for the PROFIBUS DP I O bus These blocks are not present in the system data area of the AS and are thus not activated automatically You can load these blocks into your user memory and activate them To do this install your Commissioning terminal and transfer the blocks from your memory card to the user memory of your AS using the operation LA DP_TREIB NL The loaded blocks must then be parameterized to the type numbers provided in their application and activated You activate the parameter settings in the AS input mode using the input instruction BT DP Set the desired type numbers of the DP blocks in the parameterization display using the parameters 1 3 5 and 7 If this blocks already are existing in the AS the existing type numbers were acc
30. than in the AS 488 TM the last elements are written beyond the block limit i e the next block header is overwritten Checking of the block limits corrected Note All three errors described above have been removed already with the correction Dm zZz PPN Z PN ea version M02 12b Invalid analog values If an analog value contains an invalid number this is displayed as in AS 235 In AS 488 TM 0 0000 is displayed and the system software gets into an endless loop when processing this value The display 0 0 is correct standardization of the analog value corrected KS block If a sequence cascade was filed in active state the error message KS xxxx S304 appears after loading or RSOF KS PROG corrected S5KS block If a non standardized zero in S5 or S7 floating point format is transmitted with SSKS PROFIBUS AG AG or serial link a very large number is generated from it Standardization corrected SYST WART Configuring the DP peripherals The real permitted station number 2 is rejected Also station no 2 is accepted now Copyright SIEMENS AG 1996 2003 All Rights Reserved ASE00228862A Page 13 of 22 Product Information May 2003 AS 488 TM MO02 03 NEMO compiler FO command After formatting a TML module with FO sporadically an address setting is displayed wrong though it is processed correctly FO command corrected gM ASBEDIEN NT When using the NT operating console
31. uctures CD couplings must be replaced by DI couplings before loading Loading a filed structure from AS to AS using the command LAB name is only possible from an AS 235 with a diskette drive Saving from AS to AS on diskette using the command ARB name is only possible on an AS 235 with diskette drive Use of an AS 488 TM as the central configuring station is not envisaged i e all commands which are not directed to the own AS like for example the LABR and ARBR commands are not allowed from the AS 488 TM and may lead to malfunctions in both AS When using the function Read RAM by PROGRAF AS from an AS 488 TM the number of transmit telegrams per cycle in the AS is limited by the parameter settings of FSA ORPA in the AS 488 TM A FSA ORPA F P 26 10 Structuring of I O modules with STRUK EA via the system bus CS 275 or PROFIBUS TM has not been released for AS 488 TM S5KS Blocks When projecting S5KS blocks special care must be taken to ensure that these are always placed in the same cycle for the same module and the same channel The S5KS blocks use a joint send buffer for each module and channel If this send buffer is accessed at the same time by two cycle levels for example by cycle 2 and 3 with the S5KS blocks the send data to be transported can occasionally be corrupted or destroyed when it enters the send buffer the receiver then receives corrupt data Time after network is switched on On rare occasions it may
32. v PROGRAF USER The system file of the AS 488 TM automation system is then known to PROGRAF AS Carry out your PROGRAF AS configuring in the usual manner The following version M02 03 contains an update of the system SW file AS SYS which has the following extensions Driver blocks DP4E and DP4A for PROFIBUS DP included since M02 01 Driver block DPCH for ET200M channel diagnosis see chapter 4 2 The new AS SYS file is necessary so that these new standard function blocks are known in PROGRAF AS and can be re compiled or defined Note PROGRAF AS NT V4 02 already includes the current file AS SYS Note From PROGRAF AS V3 00 onwards the AS commands FORM LA AR DI and DEL are also allowed for online structuring After LA name PROGRAF AS terminates the coupling to AS 488 TM message BUS STRUCTURING ABORTED The coupling must be re established after the loading and reset procedure is complete new ANMS Caution Under no circumstances should PROGRAF AS be stopped while the AS is being reset as this causes the bus structuring in the AS to remain active If it should happen nonetheless the user of PROGRAF AS should logon on the same AS 1 3 Master Type File for COM ET200 COM PROFIBUS In the DOCU folder on the IBS tool diskette there are two files for the ET200 configuration tool COM ET200 or COM PROFIBUS The master type file SI8050AX 2MH must be copied to the MASTERS directory of the installed COM PROF