Alaris System cleaning best practices

image

Contents

1. Administration set loading IUI inspection and Alaris System cleaning instructions Administration set loading instructions When loading the administration set 1 Hold upper fitment above fitment recess and lower into recess 2 Press safety clamp fitment into recess in the Alarise Pump module 3 Firmly press tubing into the air in line sensor 4 Verify that the administration set is free from kinks twists and correctly installed Alaris System cleaning instructions Do e Before cleaning turn the instrument off and unplug the power cord from the AC power source e Keep instrument upright and do not allow any part of instrument to become saturated with or submersed in fluid during cleaning operation e Use a soft cloth dampened with warm water and a mild nonabrasive cleaning solution to clean all exposed surfaces For sanitizing or antibacterial treatment use 10 bleach solution and water e Use a soft cloth dampened with water to rinse off cleaning solution e Allow devices to dry before attaching modules Dry time is dependent on temperature humidity and ventilation of the area Note Please consult cleaning solution manufacturer for dilution Cautions IUI inspection Inspect inter unit interface IUI connectors on each Alaris PC unit and on each module prior to every use Do not Do not spray fluids directly onto the instrument or into rear case of the instrument Do not apply
2. IFO568 01 0411 QTY ANZ Lit No AL097 Sep11 v1 carefusion com T CareFusion
3. cleaning solution into the metal pins of the IUI connectors Do not use hard or pointed objects to clean any part of the instrument A soft bristled brush may be used to clean hard to reach and narrow areas Do not use compressed air to dry the instrument this could force fluid into the instrument Do not steam autoclave EtO sterilize immerse the instrument in fluids or allow fluids to enter the instrument case Do not allow solutions to collect on the instrument Residue build up might cause the moving parts to become sticky and hinder their operation over time e All recommended solutions must be diluted per the manufacturer s recommendation e Any dropped or damaged instruments should be sent to the biomedical engineering department e This tip sheet is not intended to be comprehensive instructions for cleaning of the Alaris System It reinforces points only For complete instructions warnings and cautions refer to the Alaris System s User Manual Warning Failure to follow these instructions may result in an electrical hazard and or may damage the instrument CareFusion New Zealand 14B George Bourke Drive Mt Wellington Auckland 1060 Ph 0508 422 734 CareFusion Australia Unit 3 167 Prospect Highway Seven Hills NSW 2147 Ph 1300 729 258 2011 CareFusion Corporation or one of its subsidiaries All rights reserved Alaris is a trademark or registered trademark of CareFusion Corporation or one of its subsidiaries

Download Pdf Manuals

image

Related Search

Related Contents

  CNStats 4.4 User Manual - CN  HYMT264 User Manual - Hyundai Power Equipment    Instructions for use  Conair BC178 hair stylers  LogiLink UA0180  HYDROLEAN Manual de instalación,funcionamiento y    eLINE電動ピペット取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file