Home

NYP78 800-P78 8M – Mic croscop pe Docu mentati ion Set

image

Contents

1. Sharpness contrast and saturation can be adjusted in detail Ref 40 e Image Size e e Small data size enables you to capture more images with single memory card and easy to handle whereas large data size is more suitable for printing and enlargement ref P29 e Auto Off e When no operation is performed for the selected time length the monitor would shut off and camera enter standby mode When the AC adapter is connected it is set for 30 minutes automatically Ref P84 e Date Imprint e e Date and time of recording can be imprinted on pictures Ref P77 Other thing you can do with CoolPix P7800 Exposure Bracketing enables to capture image with 3 different exposures in a single shot Ref P38 uua Wi WII Hi Ii ii 0 3 Base Pic 0 3 Active D Lighting reduces over and under exposure preserve details in highlights and shadows creating photograph with natural contrast Ref P56 Ocular Micrometer Installation 021mm ocular micrometer can be installed into NY P7800 First turn the adapter tip to counter clockwise and remove installing bracket Next insert ocular micrometer to bracket with printed surface facing down Finally reinstall bracket to adapter body to set Printed surface facing down S11 CF Special design micrometer for digital camera adapter 10mm 100split pitch 0 1mm S11 CF removes numbers written on the micrometer and also shifted scale slightly to the edge for clearer view
2. MeCan S NYP7800 P78M Microscope Documentation Set imaging A P Photomicrograph with dapter Parts Nikon CoolPix P7800 Main Unit P 7800 Relay Lens Attachment 030mm W C Mount Conversion jeere Ring Installation Next screw adapter into camera and install Remove lens ring first Rotate counter clockwise When using 30mm conversion ring Insert main unit all the way down to the 30 Oring It should be fit tight Bottom should be lined When using C mount sleeve 1 Attach C mount sleeve into microscope C mount 2 Insert main unit with 30mm conversion ring into C mount sleeve and secure with screw iH H Make No Gap Installation to Microscope Installing to Eyepiece Remove eyepiece and insert adapter to eyepiece tube When tube inside diameter is 30mm attach conversion ring to main unit first and insert it into eyepiece tube When itis 23 2mm insert main unit directly into eyepiece tube Adapter may start to rotate when diopter ring is attached to eyepiece In such case insert the adapter after turning diopter ring to either end Nikon F phototube Insert main unit to Nikon F tube In recent Nikon models the ones With V T phototube part is equipped with F tube In older models Optiphot Biophot SMZ 2T trinocular models are with F tube When 35mm camera or Polaroid system is installed to microscope it is likely be same as t
3. asic operation and initial set up O Easy Setting Easy semi auto mode Set the Mode Dial to Scene e Press Menu Button and rotate command dial to select Landscape Press OK e Press Zoom control to T right Zoom up till there will be no vignette Zoom W ee Zoom T e Focus with microscope focus handle while checking image on LCD viewer Focus point is different for microscope and digital cameras Please make sure to focus with microscopes while watching LCD viewer e Press Shutter Release or remote shutter to capture image e Press the Playback Button to check image taken e Rotate Exposure Dial and adjust exposure level for brighter and for darker O Manual Setting Try manual setting when not satisfied with brightness focusing or color level of the image taken with easy setting Rotate and set Mode Dial to M manual e Press Focus Mode on the multi selector Select MF manual focus and press OK e Using Multi Selector set focus level up toce Infinite and fix e Adjust the focus with microscope fine adjusting handle e Press Zoom control to T right Zoom up till there will be no vignette e Press Quick Menu Button and select ISO Sensitivity to set ISO level ISO sensitivity is camera s base sensitivity Higher the number more you be able to capture images in dark environment However when it is set higher than 800 noise starts to appear therefore try keeping it low level as long as
4. he old models SMZ 10 require optional sleeve Adapter may start to rotate when diopter ring is attached to eyepiece In such case insert the adapter after turning diopter ring to either end C mount C mounts is often used for attaching CCD cameras and has male screw of outer diameter 25 4mm First attach C mount sleeve to microscope C mount Second insert main unit with 30mm conversion ring into C mount sleeve and secure with screw Compatible only with direct 1 0x C mount C mount with lens inside should not be used Olympus PT phototube A PT phototube has an outer diameter of 38mm with curving threads at the top U SPT SZ PT tubes J are with PT tube When 35mm camera or e Polaroid system is installed to microscope it is likely be PT tube It requires fixation sleeve NY BH option to secure adapter to microscope JIS phototube JIS tube has outer diameter 25mm and inner diameter 23 2mm Old Olympus models are 3 often equipped with JIS tube It requires fixation sleeve NY JIS option to secure adapter to microscope NY JIS without NY JIS image may come out blurry Camera Setting WE Main Features O 60 Exposure Dial Function Button 1 Quick Menu Button Rotary Multi Selector Shutter Button Zoom Control Power Switch OK apply select btn Mode Dial Function Button 2 Main Command Dial Menu Button Please refer to camera manual for b
5. there is no light shortage Exposure Setting P49 e Rotate Sub Command Dial and select lowest F value Aperture Shutter speed value Next rotate Command Dial to change Shutter Speed until Exposure Indicator indicate center value 0 ales Oa Exposure indicator e Take a picture for a test When image is too bright try shorter shutter speed In the same manner when image is too dark try longer shutter speed Brightness of image depends on following 3 criteria Please refer when using manual setting Highs ISO e e e Low Lows 4 Exposure F gt e High Shutter Speed e e Short Long o o e When you have a wireless remote control ML L3 press Self Timer Self Timer Select Remote Control and press OK e When setting is finished take a picture for test using Remote Control e Pressing Play button after taking shot enables you to see and check image e Registering the setting in mode dial U1 U2 or U3 enables you to shoot next time with the same setting by just switching to this mode Press Menu Button Use multi selector to choose Save User Setting and press OK O Other Setting Please also refer to CoolPix P7800 user manual for detail e White Balance Please adjust white balance manually when it is hard to produce desired image due to the sample color or tone of light Ref 35 e Picture Control Change the settings for image recording according to your preference

Download Pdf Manuals

image

Related Search

Related Contents

    GoAmerica for RIM Wireless Handhelds  068122 Débouch`vit salle de bains 1 L _1369_ 4D    OM, McCulloch, Cabrio Plus, 257 L, 257 B, 297 L, 953900739  Yealink T3X-V70 Release Notes  エプソン ビジネス プロジェクター  Setup and Users Manual  About PERFECTRON Wide Temperature Design Principle  

Copyright © All rights reserved.
Failed to retrieve file