Home

Hardware User`s Manual Elevated plus-maze

image

Contents

1. WARNING To clean Perspex Plexiglas parts never use alcohol or alcohol derived products otherwise stripes will appear in the material 9 PREVENTIVE MANTEINANCE EXPERIMENT CLEANING THE PERSPEX PARTS Ww 10 SPECIFICATIONS Model Description Arm length Height Walls Height From floor LE 840 Standard Rats 100 cm x 10 cm 50 cm socmGrey 65 cm socmBlack cm socmBlack LE 842 Standard Mice 65cmx6cm 15cm fascmGrey i5scmBlack cm i5scmBlack Elevated plus maze Panlab IM pos dd DECLARACI N DE CONFORMIDAD DECLARATION OF CONFORMITY DECLARATION DE CONFORMIT Nombre del fabricante Panlab s l u Manufacturer s name www panlab com Nom du fabricant info panlab com Direccion del fabricante Energia 112 Manufacturer s address 08940 Cornell de Llobregat Adresse du fabricant Barcelona SPAIN Declara bajo su responsabilidad que el producto ELEVATED PLUS MAZE Declares under his responsibility that the product D clare sous sa responsabilit que le produit Marca Brand Marque PANLAB Modelo Model Mod le LE 840 LE 842 Cumple los requisitos esenciales establecidos por la Uni n Europea en las directivas siguientes Fulfils the essential requirements established by The European Union in the following directives Remplit les exigences essentielles tablies pour l Union Europ enne selon les directives suivantes 2011 65 EU Restricci n de ciertas Sustancias
2. Peligrosas en aparatos el ctricos y electr nicos ROHS Restriction of the use of certain Hazardous Substances in electrical and electronic equipment ROHS Restriction de l utilisation de certaines substances dangereuses dans les quipements lectriques et lectroniques ROHS Analisis de riesgos Risk assessment Analyse des risques Para su evaluaci n se han aplicado las normas armonizadas siguientes For its evaluation the following harmonized standards were applied Pour son valuation nous avons appliqu les normes harmonis es suivantes En consecuencia este producto puede incorporar el marcado CE Consequently this product can incorporate the CE marking En cons quence ce produit peut incorporer le marquage CE En representaci n del fabricante Manufacturer s representative En repr sentation du fabricant Carme Canalis General Manager WD Panlab s l u a division of Harvard BioScience A ven Cornell de Llobregat Spain 26 06 2014 Elevated plus maze
3. Hardware User s Manual Elevated plus maze y BL CY References L E840 76 0074 LE842 76 0075 Version V24 10 2014 Panlab s l u International Calls 34 934 750 697 p a n la b H Harvard C Energ a 112 Domestic Call 934 190 709 Apparatus 08940 Cornella de LL Barcelona Fax 34 934 750 699 Spain Info panlab com www panlab com Limitation of Liability PANLAB does not accept responsibility under any circumstances for any harm or damage caused directly or indirectly by the incorrect interpretation of what is expressed in the pages of this manual Some symbols may have more than one interpretation by professionals unaccustomed to their usage PANLAB reserves the right to modify in part or in total the contents of this document without notice Panlab H Aidez ir 1 SYMBOLS TABLE Recognising the symbols used in the manual will help to understand their meaning DESCRIPTION SYMBOL Warning about operations that must not be done because they can damage the equipment Warning about operations that must be done otherwise the user can be exposed to a hazard Decontamination of equipment prior to disposal at the end of their y operative life AL 2 GOOD LABORATORY PRACTICE Check all units periodically and after periods of storage to ensure they are still fit for purpose Investigate all failures which may indicate a need for service or repair Good laboratory practice recommends that the un
4. TIVE MANTEINANCE SPECIFICATIONS Elevated plus maze Harvard Apparatus Panlab H pos did 5 INTRODUCTION Panlab has developed two elevated plus mazes one Standard for rats LE840 and another for mice LE842 gt sm x Saf Figure 1 Mouse elevated plus maze Figure 2 Rat elevated plus maze The mazes are mounted on supports which give them a certain height from the floor They form a cross of two arms of equal surface area but with the difference that one of them is delimited by lateral walls and the other one not Both models are made in black Plexiglas The mazes are supplied with three types of walls e Grey for standard experiments e Black for standard experiments e Transparent for specific experiments aimed to complement the standard analysis of animal position with an ethopharmacological analysis of animal behaviour These walls are lower than the standard ones Grey floors are also provided as to facilitate video tracking when the animals are black These walls are optional and are not supplied by default For details see Anseloni and Branfdao 1997 Ethopharmacological analysis of behaviour of rats using variations of the elevated plus maze Behay Pharmacol 8 533 40 Elevated plus maze Panlab H Aidez ir 6 EQUIPMENT DESCRIPTION In both models rat and mouse the mazes are mounted on supports which give them a certain height from the floor The support consists of two black Plexiglas par
5. damage during transport D Place the equipment on a flat surface and leave at least 10 cm of free space between the rear panel of the device and the wall Never place the equipment in zones with vibration or direct sunlight The manufacturer accepts no responsibility for improper use of the equipment or the consequences of use other than that for which it has been designed PC Control Some of these instruments are designed to be controlled from a PC To preserve the integrity of the equipment it is essential that the attached PC itself conforms to basic safety and EMC standards and is set up in accordance with the manufacturers instructions If in doubt consult the information that came with your PC In common with all computer operation the following safety precautions are advised WARNING To reduce the chance of eye strain set up the PC display with the correct viewing position free from glare and with appropriate brightness and contrast settings e To reduce the chance of physical strain set up the PC display keyboard and mouse with correct ergonomic positioning according to your local safety guidelines Elevated plus maze Panlab H 4 TABLE OF CONTENTS 10 SYMBOLS TABLE GOOD LABORATORY PRACTICE UNPACKING AND EQUIPMENT INSTALATION TABLE OF CONTENTS INTRODUCTION EQUIPMENT DESCRIPTION ASSEMBLING THE ELEVATED PLUS MAZE WORKING WITH THE EQUIPMENT CONDUCTING AN EXPERIMENT CLEANING PERSPEX PREVEN
6. it be periodically serviced to ensure the unit is suitable for purpose You must follow preventive maintenance instructions In case equipment has to be serviced you can arrange this through your distributor Prior to Inspection Servicing Repair or Return of Laboratory Equipment the unit must be cleaned and decontaminated Decontamination prior to equipment disposal In use this product may have been in contact with bio hazardous materials and might therefore carry infectious material Before disposal the unit and accessories should all be thoroughly decontaminated according to your local environmental safety laws Elevated plus maze Panlab H d 3 UNPACKING AND EQUIPMENT INSTALATION WARNING Failure to follow the instructions in this section may cause equipment faults or injury to the user A No special equipment is required for lifting but you should consult your local regulations for safe handling and lifting of the equipment B Inspect the instrument for any signs of damage caused during transit If any damage is discovered do not use the instrument and report the problem to your supplier C Ensure all transport locks are removed before use The original packing has been especially designed to protect the instrument during transportation It is therefore recommended to keep the original carton with its foam parts and accessories box for re use in case of future shipments Warranty claims are void if improper packing results in
7. ts assembled In top of that two arms are mounted of equal surface area but with the difference that one of the arms is delimited by lateral walls and the other one not as shown in Figure 3 ARMS SUPPORT Figure 3 Rat elevated plus maze Elevated plus maze Panlab H ps bid 7 ASSEMBLING THE ELEVATED PLUS MAZE Bez DETALLE A aa EGALA VT 5 Z t DETALLE C ESCALA T 2 X B Ds Figure 4 Assembling the elevated plus maze To assembly the Plus maze proceed as follows 1 Assembly the maze support by sliding the two parts one inside the other by the central guides X see Figure 4 Assembling the elevated plus maze 2 Assembly the Grey walls joining the 3 pieces with the nuts A see Figure 4 Assembling the elevated plus maze 3 Fixthe Grey walls to the plus maze with screws B and C see Figure 4 Assembling the elevated plus maze Elevated plus maze Panlab H Aidez ir 8 WORKING WITH THE EQUIPMENT 8 1 CONDUCTING AN EXPERIMENT Read carefully the instructions given of the Smart program for conducting an experiment Once the experiment has ended you should clean the maze so that is in good condition for the next experiment 8 2 CLEANING PERSPEX To clean the Perspex Plexiglas pieces you can use a slightly wet cloth and then dry them with a dry cloth If they re too dirty you can wet the cloth with a soapy solution to clean them then remove foam with a wet cloth and finally dry them with a dry cloth

Download Pdf Manuals

image

Related Search

Related Contents

Rupture mode d`emploi    User Guide v1.1.2  Abécédaire des séjours étudiants - adultes  Bedienungsanleitung ( Deutsch)  

Copyright © All rights reserved.
Failed to retrieve file