Home

USER MANUAL

image

Contents

1. 15 Color Temptation 15 Red Green and Blue 15 Shortcuts 15 Shortcut Group ts 15 OSD Setting Menu 16 L arigtagg ica cate 16 OSD TIME aa 16 OSD Tans snc etes 16 VOWING 6 ncc Y 6 RESO n 6 SW Version Specifications Supported Resolutions and Frame Rates 18 19 One Year Limited Warranty Back 20 PRODUCT CONTENTS 10 1 Field Monitor Sunshade Sunshade thumbscrews x2 Tabletop bracket Tabletop bracket thumbscrews x2 vor vr so Adhesive touch strip Tally kit 4 pin XLR power supply AC power cable User manual OVERVIEW 1 4 20 threaded sockets Screen Tally Light ntrast Focus knob ume Camera knob UJ Headphone jack rightness Esc knob Video input buttons Selector Menu knob Video YPbPr HDMI SDI 1 SDI 2 Function buttons F1 F2 F3 FA F5 Power LED Tally connector Power switch Battery plate f J IO O L p n OO e r e i OO gt dd DC power input HDMI input XLR input HDMI output SDI ports Audio inputs Y PbPr component video ports POWERING THE FIELDVISION There are three ways to power the FieldVision 4 pin XLR input 12 V DC inp
2. FIELDVISION OCM 10 PSM 10 1 PRO LCD MONITOR USER MANUAL elvid INTRODUCTION hank you for choosing Elvid T The Elvid OCM 10 PSM FieldVision 10 1 Pro LCD Monitor with Scopes is perfect as a director s monitor Its signature all scopes setting displays a histogram audio column vector RGB histogram and YUV waveform on the sides with an uninterrupted view of your incoming video frame enabling instant and constant feedback without disrupting your view of the image Anamorphic mode can be set to 1 3x or 2 0x to offer an accurate view of your picture s aspect ratio when shooting with an anamorphic lens The unique nine grid mode divides the frame into a 3 x 3 grid as a composition aid and allows you to magnify a specific area without adjusting your frame A zebra exposure indicator and false color mode with onscreen key display provide visual guides so you can achieve precise exposure levels A focus assist tool with two sensitivity levels helps fine tune your focus There are also broadcast specific features like overscan safety frame markers and a tally light The FieldVision is equipped with Video YPbPr HDMI and two SDI inputs all with loop through making this monitor compatible with most pro video connections Native resolution is 1280 x 800 and you can easily change the native 16 10 aspect ratio to fit your needs Onboard controls include five function buttons that can be programmed from a palette of 22 functions
3. bi 7 I Vector Displays a vectorscope which is an overall color saturation meter for all colors in the image Waveform Displays a waveform of the image s exposure level in RGB parade YUV or Y Audio Column Displays the audio level meter onscreen PICTURE SETTING MENU Scan Mode Adjusts the aspect ratio for the FieldVision s screen You can choose Auto default Over Scan or Full Screen Auto displays the image at the video signal s native aspect ratio so you can see the entire video image e g if the signal s native aspect ratio is 4 3 it will display at 4 3 Over Scan displays only the broadcast safe image Full Screen changes the image s aspect ratio to 16 10 regardless of the video signal s native aspect ratio Camera Mode Camera mode scales the image to fill the screen and adjusts the monitor resolution so the video isn t interrupted This is useful when shooting on a DSLR You can also access this mode while on the main screen by pressing the Camera knob Flip Flips the display horizontally vertically or both Freeze Freezes the current onscreen image Pixel to Pixel Turns off scaling and displays the incoming video signal in its native resolution and aspect ratio with 1 1 pixel mapping If the picture is larger than the monitor s 1280 x 800 resolution the center of the image will appear onscreen Zoom Magnifies the center of the onscreen image You can choose x4 x9 and x16 Anamorphic Set
4. proof of purchase Shipment of the defective product is at the purchaser s own risk and expense For more information or to arrange service visit www elvidcinema com or call Customer Service at 212 594 2353 Product warranty is provided by the Gradus Group www gradusgroup com Elvid is a registered trademark of the Gradus Group 2015 Gradus Group LLC AII Rights Reserved E ELVID f A Gradus Group Brand www elvidcinema com GG1
5. until it locks into place To turn on the FieldVision press the power switch to the On position The power indicator LED will glow green GETTING STARTED MONITORING SOUND You can monitor sound via the integrated speaker or the 3 5 mm stereo headphone jack To monitor via the headphone jack plug in a pair of compatible headphones MOUNTING THE FIELDVISION Use one of the 1 4 20 threaded sockets in the FieldVision to attach the monitor to your mounting system Make sure your bracket can support the monitor Alternatively you can mount the included tabletop bracket by attaching it with the included bracket thumbscrews CONNECTING TO YOUR CAMERA To connect the FieldVision to your camera follow these steps 1 Choose the desired video signal and use the appropriate cable to connect your camera to the corresponding input connections on the back of the monitor 2 Press the video input button composite video YPbPr HDMI SDI or SDI2 that corresponds to your video input signal LOOP THROUGH The FieldVision is equipped with loop through also known as pass through for all of its video inputs To loop the video signal through the monitor connect your camera to the desired video input and then connect the appropriate cable to the corresponding output on the back of the monitor TALLY CONNECTION If desired you can connect your tally cable to the FieldVision s RS232 D sub 9 pin tally connector o
6. TENTS PiecaltiOls entire e 3 Product 5 OVERVIEW 6 Powering the FieldVision 8 Monitoring 9 Mounting the FieldVision 9 Connecting to Your Camera 9 Loop Through m m 9 Tally Connection sessies 9 The 5 10 The Menu sce 11 Navigating the 1i Assistant Functions Menu 11 Check Field sss 11 Pseudo as 11 Zebfa Crossa 11 FOCUS ASSISU imi intentis 1i Focus Color 11 Pattern 11 arker Display 11 Center 11 arker Type 12 Safety ARCA scans 12 Marker Color cete 12 Duci 12 Scopes Menu 13 Y Histogram eeeeesseseeeee 13 Audio Column ete 13 ni 13 RGB Histogram 13 Waveform mueeseeeeeee 13 AISCE Sremca 13 Picture Setting 14 SEAN petet 14 Camera 4 ise 4 2 C P 4 Pixel to Pixel ciet 14 ZOOM statist RE eos erence cts 14 Jat ere cet 14 Color Setting
7. and saved in three independent groups Four knobs facilitate menu navigation access focus and Camera DSLR modes and adjust monitor settings There s also an integrated mono speaker and a 3 5 mm stereo headphone output for live audio monitoring PRECAUTIONS Please read and follow these instructions and keep this manual in a safe place Exposure to high sound levels can cause permanent hearing loss Avoid listening at high volumes for extended periods of time Keep this product away from water and any flammable gases or liquids Make sure this product is powered off when plugging it into a power source Use only the correct recommended voltage Do not attempt to disassemble or repair this product Do not place or store the FieldVision acedown since this can damage the screen Handle this product with care Avoid any unnecessary impacts to this product Do not block the vents in this product Disconnect this product from its power source before storage and during electrical storms Do not use chemical solutions to clean this product Clean this product with only a soft dry cloth Keep this product away from children Make sure that this product is intact and that there are no missing parts To avoid damage to this product be careful not to overtighten or improperly thread any of the threaded fittings All photos are for illustrative purposes only TABLE OF CON
8. cted color will appear onscreen You can select gray red green or blue Check Field mode is useful for calibrating the monitor Pseudo Color Replaces the true colors of the image with a standard set of colors displayed in an onscreen chart that represent exposure levels The higher or hotter the exposure the higher the color will be in the chart As exposure decreases the color will descend through the chart This mode is useful for quickly and accurately determining your shot exposure Zebra Crossing Displays animated black and white stripes through areas of the image that are overexposed You can set this mode to high 70 or low 100 sensitivity Focus Assist Also known as peaking this focus assist tool displays an outline around in focus areas of the image You can set this tool for high or low sensitivity to edge detection You can also access this mode while on the main screen by pressing the Focus knob Focus Color Sets the color of the outline for Focus Assist mode You can choose red default green blue or white Pattern Gen Displays color bars on the screen Marker Display Menu Center Marker Displays a marker in the center of the screen THE MENU Marker Type Displays an onscreen box as a safety frame marker at a specific aspect ratio You can set this to 16 9 4 3 2 35 1 or 1 85 1 Safety Area Displays an onscreen box as a safety frame marker at a percentage of the sc
9. e Zoom Flip Freeze DSLR Camera Marker Color Marker Type Safety Area Center Marker Nine Grid Mute and Pattern Gen Shortcut Group You can create three independent groups of shortcut button assignments labeled 0 1 and 2 OSD SETTING MENU Language You can set the onscreen language to English or Chinese Osd Time Determines the number of seconds the menu remains onscreen You can choose 5 10 15 20 25 or 30 seconds default Osd Trans Makes the menu translucent The default setting is Off opaque Volume Adjusts the monitoring volume from O to 100 You can also adjust this by rotating the Volume Camera knob Mute Mutes the monitoring volume of the FieldVision Reset Restores the FieldVision to the factory default settings This will erase all current settings and replace them with the default settings SW Version Displays the current software version of the FieldVision SPECIFICATIONS Panel size 10 1 IPS panel Backlight LED Native resolution 1280 x 800 Aspect ratio 16 10 Brightness 650 cd m Contrast ratio 800 1 Response time 25 ms Viewing angle 178 89 89 0 0 nputs 3G SDI x2 HDMI component composite analog audio Outputs 3G SDI x2 HDMI component composite headphone 3 5 mm stereo Input voltage 7 24 V DC via 4 pin XLR or 2 1 mm DC barrel Current 1500 mA Power consumption 16 W Available battery plates o FBP F970 included Sony L series ba
10. nection to make sure it s reliable and properly connected Check whether the color saturation is properly configured Make sure Check Field mode is disabled If you are using component video make sure that all the cables are attached correctly and fully plugged in Check your cables to make sure they are reliable and properly connected If you are powering the FieldVision via AC power use only the recommended power adapters Make sure the video resolution and frame rate are supported by the monitor See the Supported Resolutions and Frame Rates chart on page 18 Make sure the monitor is set to the proper video input Check your cables to make sure they are reliable and properly connected Try using a new cable Check your video source output to make sure it s listed in the Supported Resolutions and Frame Rates chart on page 18 Make sure the video resolution and frame rate are supported by the monitor See the Supported Resolutions and Frame Rates chart on page 18 Check your cables to make sure they are reliable and properly connected Make sure Pseudo Color mode is disabled Make sure your monitor is properly calibrated Make sure scan and zoom modes are disabled Check whether the aspect ratio is set correctly Turn the monitor s volume all the way down mute the volume via the OSD Setting menu or plug headphones into the headphone jack ONE YEAR LIMITED WARRANTY This Elvid product is warranted to
11. r the included bare end adapter Refer to the included insert for the specific tally pin connections THE SUNSHADE THE SUNSHADE The sunshade prevents glare on the monitor s screen by blocking out stray light and is useful when shooting outdoors To attach the included sunshade follow these steps 1 Unfold the sunshade and place it along he top and sides of the monitor Tip For a more secure fit attach the included adhesive touch strip along the op edge of the monitor This will help hold the sunshade in position 2 Align the sunshade s screw holes with he 1 4 20 threaded sockets in the sides of the monitor 3 Use the included thumbscrews to fasten the sunshade in place THE MENU Before using the FieldVision you will need to make sure the monitor s settings are properly configured All of the setting configurations are located in the main menu which has seven submenus Assistant Functions Marker Display Scopes Picture Setting Color Setting Shortcuts and OSD Setting NAVIGATING THE MENU To access the menu press the Menu knob The submenus are located in the left column of the main menu window Turn the Menu knob to navigate the menu To make a selection press the Menu knob Press the Esc knob at any point to return to the previous menu or screen without making a selection ASSISTANT FUNCTIONS MENU Check Field In Check Field mode only the sele
12. reen size You can set this to 80 85 90 93 or 96 Note that this percentage corresponds to the screen size and not the aspect ratio Marker Color Changes the color of the onscreen markers You can choose white default gray black red green or blue Nine Grid Divides the screen into a 3 x 3 grid of nine panels any of which you can select to display at full screen This is useful for zooming in on a specific part of the image to check or fine tune the focus without adjusting or changing the frame Use the Menu knob to navigate the grid and select a panel When the selected panel is at full screen press either the Menu or Esc knobs to return to the grid Press the Focus or Camera knobs to maintain this panel as your current display To return to the grid enable Nine Grid mode via the Marker Display menu All Scopes Display all the scopes in the Scopes menu Histogram Audio Column Vector RGB Histogram and YUV Waveform on the sides of the frame with an uninterrupted view of your incoming video image The default setting is Off You can also add the scopes individually to display them over your image Y Histogram Indicates the overall level of exposure from light to dark and shows the percentage of the image at a particular exposure level RGB Histogram Displays the overall exposure level Y Histogram as well as red green and blue levels on a single scope YUV Parade i 4 Ji ai
13. the original purchaser to be free from defects in materials and workmanship under normal consumer use for a period of one 1 year from the original purchase date or thirty 30 days after replacement whichever occurs later The warranty provider s responsibility with respect to this limited warranty shall be limited solely to repair or replacement at the provider s discretion of any product that fails during normal use of this product in its intended manner and in its intended environment Inoperability of the product or part s hall be determined by the warranty provider If the product has been iscontinued the warranty provider reserves the right to replace it with model of equivalent quality and function fab Eh e his warranty does not cover damage or defect caused by misuse eglect accident alteration abuse improper installation or maintenance EXCEPT AS PROVIDED HEREIN THE WARRANTY PROVIDER MAKES NEITHER ANY EXPRESS WARRANTIES NOR ANY IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE This warranty provides you with specific legal rights and you may also have additional rights that vary from state to state To obtain warranty coverage contact the Elvid Customer Service Department to obtain a return merchandise authorization RMA number and return the defective product to Elvid along with the RMA number and
14. this to match the size of your anamorphic lens You can choose 1 3x 2 0x and 2 0x mag The 2 0x mag setting magnifies the center of the image to fill the screen It s useful to check the focus when the scaled image appears too small onscreen Note Anamorphic mode will not work in All Scopes mode COLOR SETTING MENU In the Color Setting menu you can adjust Brightness Contrast Hue Chroma and Sharpness from 0 to 100 You can also adjust brightness contrast and volume without opening the menu While on the main screen rotate the Esc knob for brightness the Focus knob for contrast and the Camera knob for volume Color Temp You can select from the presets 9300 6500 default 5600 and 3200 K You can also configure your own custom setting by turning the knob to User Customizing the color temperature is recommended only for advanced users Red Green and Blue When using one of the preset color temperatures these levels are displayed onscreen in the submenu but cannot be accessed These are accessible only when setting the custom color temperature via the Color Temp submenu SHORTCUTS MENU To save time when using the FieldVision you can assign unique settings to the five function buttons to suit your specific needs The options for customizing the function buttons are Pseudo Color Y Histogram Audio Column Vector RGB Histogram Waveform Check Field Zebra Crossing Focus Assist Focus Color Scan Mod
15. tteries o FBP LPE6 Canon LP E6 batteries o FBP PD28 Panasonic D28 batteries Working temperature 14 122 10 50 C Storage temperature 4 F 140 F 20 60 C Mount size 1 4 20 x3 Dimensions W x x D 10 2 x 7 6 x 2 3 25 9 19 3 x 5 8 cm Weight 1 8 Ib 816 5 g SUPPORTED RESOLUTIONS AND FRAME RATES HDMI 1080i 60 50 1080p 60 50 30 25 24 720p 60 50 576p 576 480p 480 SDI 1080PsF 25 24 1080p 60 50 1080i 60 50 720p 60 50 576 480i 480p TROUBLESHOOTING The FieldVision will not turn on The screen is flickering or blinking The screen displays only a black and white image The FieldVision is turned on but there is no onscreen image The FieldVision is not receiving a video signal No signal is displayed onscreen The colors are inaccurate The onscreen image size is incorrect The FieldVision is emitting a high pitched whine feedback If you are powering the FieldVision with a camera battery make sure that the battery is fully charged If you are powering the FieldVision via AC power check your power connection to make sure it s reliable and properly connected Try switching AC power sources Check your video cables to make sure they are reliable and properly connected If you are powering the FieldVision with a camera battery change your battery If you are powering the FieldVision via AC power check your power con
16. ut and a Sony L Series camera battery 4 PIN XLR To power the FieldVision via the 4 pin XLR input use a 4 pin XLR power supply and AC power cable to connect the FieldVision s 4 pin XLR DC power input to your power source To power the FieldVision via the 4 pin XLR input follow these steps 1 Fully insert a 4 pin XLR power supply into the 4 pin XLR DC power input on the back of the monitor The connector should click into place when fully nserted 2 Use an AC power cable to connect the XLR power supply to your AC power source To turn on the FieldVision press the power switch to the On position The power indicator LED will glow green 12 V DC INPUT To power the FieldVision via the 12 V DC input use a 12 V DC adapter with the included 2 1 mm DC barrel to connect the FieldVision s DC power input to your AC power source To turn on the FieldVision press the power switch to the On position The power indicator LED will glow green CAMERA BATTERY The FieldVision has a built in battery plate that accepts all Sony L Series batteries This allows you to power the FieldVision with readily available battery packs that you may already own To power the FieldVision with a Sony L Series battery not included follow these steps 1 Place a compatible battery in the battery plate Make sure the battery s bottom contacts are aligned with the contacts in the battery plate 2 Slide the battery forward