Home
"user manual"
Contents
1. Rate power voltage 24 VDC Allowable range 20 4 to 27 6 VDC Capacity 10 W min e Insert a 3 A fuse immediately after the secondary output from the power supply Do not connect an AC power supply to the DC power input terminals eDo not perform a dielectric strength test Properly ground the PT to prevent malfunction due to noise eDo not touch the surface of the circuit board or the components mounted on it with your bare hands Discharge any static electricity from your body before handling the board When connecting the cable to the PT make sure to secure the cable and the PT The tensile load on the cable must not exceed 60 N Do not place a higher load on the cable Tum OFF the power supply to the PT before connecting or disconnecting the cable Be sure to tighten the connector screws after connecting the cable The whole system may stop depending on how the power supply is turned ON or OFF Turn ON or OFF the power supply according to the specified procedure Thoroughly confirm operation of screen data macros and host pro gramming before starting actual use Do not perform the following operations while the Memory Card is being accessed Turning OFF the power supply to the PT Removing the Memory Card eTo ensure system safety incorporate a program that periodically reads PT operation bits from the host side to check that the PT is properly operating Press touch switches with a force of 30 N max Confirm
2. fan an 5 300 i 10 j 70 10 000 322 35 100 CN4 m Connecting the Special Cable Check before Connecting 1 Waterproof cable clamps are attached to both ends of the Special Cable The cable has inner and outer waterproof packing The packing is important to maintain the cables waterproof capabilities so be sure it is not lost or damaged NSH5 PT Cable Clamp a Cable attachment Cable Unit lock Packing cap packing housing Heat shrinking tube 2 Be sure the cable clamp housing is not damaged or dirty before inserting it into the PT If the housing is damaged have it repaired to retain the waterproof capabilities P 8 Connection Procedure 1 Using a screwdriver loosen the four mounting screws on the PT s back cover QO 2 Remove the mounting screws grasp the cover by the handholds and lift out the cover 3 When the cover has been removed and the back of the PT is open the I O connector and interface on the board in the PT can be seen ON DIP Switch X DIP switch pins are ON Battery interface when set to the right Serial interface 9 i External output interface 4 24 VDC interface 71 gt 4 Using your hand lightly tighten the waterproof packing while it is attached to the housing Then use a wrench to tighten the waterproof packing to a force of 4 0 to 6 0 N m to secure it in place 10 ney Ex QY Da N AG 5 Insert the cable into
3. 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 Note Specifications subject to change without notice Printed in Japan OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711
4. system safety before pressing touch switches eDo not accidentally press touch switches when the backlight is not lit or when the display does not appear Confirm the safety of the system before pressing touch switches Do not press touch switches consecutively without pausing in between If touch switches are pressed consecutively at high speed the PT may not be able to detect the inputs Confirm that the PT has detected the input of a touch switch before pressing any other touch switch eBefore initializing screen data confirm that existing data is backed up at the CX Designer eWhen changing the password with the system menu do not reset or turn OFF the power supply until writing is finished If the password is not saved successfully the screen may not operate When using the device monitor confirm the safety of the system before performing the following operations Changing monitor data Changing operating modes Force setting or resetting Changing present values or set values eNever use volatile solvents such as benzene or thinners or chemical dusters to clean the PT Dispose of the product and batteries according to local Cf ordinances as they apply Have qualified specialists prop J erly dispose of used batteries as industrial waste LS RE ULL Blk eDo not connect a USB connector to any device that is not applicable Before connecting a USB connector to a device check the external ap pearance of the device and make
5. the PT until the heat shrinking tube is visible on the inside Heat shrinking tube o 6 Insert the cable packing into the inside of the cable clamp housing and lightly tighten the cap by hand Insert the Special A Cable into the PT amp Cable packing peace 3 i Tighten the cap with a wrench Use a tightening force of 2 0 to 3 0 N m Inspect the cable periodically to see if it has become loose Precautions for Safe Use Serial interface 24 VDC power supply interface External output interface Connect all of the connectors White 20 pin connector Black 3 pin connector Black 18 pin connector Serial interface External output interface 24 VDC interface When using RS 422A communications turn ON DIP switch pin 1 terminating resistance ON only when the PT is connected as the last communications node Note DIP switch pin 1 connects and disconnect the terminating resistance Always leave pins 2 to 4 turned OFF default setting Replace the cover insert the four mounting screws and tighten them to a force of 0 4 N m Mounting to a Control Panel A UL standard cable connection example is given below 1 When using a UL standard cable it is necessary to cut a hole in the control panel to secure the cable clamp Cable Clamp Mounting Hole Dimension 2340 2 mm aa 2 Feed the UL standard cable through th
6. NSH5 Series NSH5 SQ_ 10B V2 Programmable Terminal INSTRUCTION SHEET Thank you for purchasing a NSH5 series Programmable Terminal Please confirm that you have received the correct product and then read this instruction sheet and be sure you understand the contents completely before attempting to use the product For detailed information on specifications and usage refer to the PT and Support Software manuals Please retain this instruction sheet for future reference OMRON Corporation OMRON Corporation 2010 2013 All Right Reserved 2111272 5D Safety Precautions e Definition of Precautionary Information Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Additionally there may be severe property damage e Symbols Prohibition Indicates a general prohibition Disassembly Prohibited Disassembling any product may result in electrical shock or other injury Never attempt to disassemble any product Caution Indicates general cautionary waming or danger level information e Safety Precautions Nwarnina Do not attempt to take the PT apart and do not touch any internal parts while the power is being supplied Doing either of these may result in electrical shock Always ensure that personnel in charge properly perform installation inspection and maintenance for the PT Personnel in charge refers to individuals qualif
7. e hole then secure the cable clamp to the control panel from the inside using the lock nut When using the NSH5 232UL 3M 10M always connect the relay cable which is equipped with an RS 232C connector after feeding the UL standard cable through the hole in the wall of the control panel Tighten the lock nut to a force of 2 0 to 3 0 N m Cable packing Cap Housing Lock nut Cut a cable clamp mounting hole in the control panel using the cable diameter as a guide then feed the Gontrat i cable through the hole onToApana Relay cable included Connect the relay cable after first feeding the UL standard cable through the control panel wall Insert the cable clamp housing into the mounting hole in the control panel and secure it in place with the lock nut from the inside Adjust the cable length Tighten the lock nut to a torque of 4 0 to 5 0 N m place the rubber cable packing inside the housing and then tighten the cap to secure the cable E installing the Mounting Bracket 1 As shown below there are two holes for installing the mounting bracket Mounting bracket holes 2 Secure the mounting bracket to the PT with the two screws Mounting bracket Note Tighten the screws to a force of 0 9 N m 3 Attach a screw or other support to the wall first and then hook the mounting bracket on it to install the NSH5 Screw or other support N Mounting bracket Provided by the customer Diamet
8. er 5 mm Diameter 10 mm E External Wiring Diagram External Output Interface Item Specification Function switches SPST NO Rated voltage 24 V Max rated current 50 mA 3PST NC Rated voltage 24 V Max rated current 100 mA Min applicable load 1 mA at 5 VDC DPST NO Rated voltage 24 V Max rated current 100 mA Min applicable load 4 mA at 24 VDC Emergency Stop Switch The status of the emergency stop switch DPST NC contacts is output externally by a direct output via the Special Cable x Always connect the emergency stop switch to a safety circuit Emergency stop switch Stop switch Enabling switch NSH5 Emergency stop switch DPST NC Special Cable l EMG1A1 p n q nu g EMG2AN ii EMG1 EMG2 i i Safety circuit i i i EMG2A2 i EMG1A2 Enabling Switch The status of the enabling switch DPST NO contact is output ex ternally by a hard wired output from the Special Cable k Always connect the enabling switch to a safety circuit NSH5 Enabling switch N DPST NO Special Cable ENB1 ENB2 ENBIAT p X ENB2A1 F i ii E PEERAA i i i i ii i ioi i 4 4 i it Safety cae i it circuit 1 i i i 1 i ENB2A2_ i il v i H ENB1A2 i ii Function Switches The status of function switches F1 F2 F6 and F7 are output exter nally by direct outputs via
9. ied and responsible for ensuring safety during machine design installation operation maintenance and disposal Ensure that installation and post installation checks are performed by personnel in charge who possess a thorough understanding of the machinery to be installed Do not attempt to disassemble repair or modify the PT Doing so may impair the safety functions Do not use the input functions of the PT such as the function switches or switches on the touch panel in applications that involve human life in applications that may result in serious injury or for emergency stop switches Always connect the emergency stop switch and enabling switch to safety circuits Serious accidents may occur if a malfunction occurs while the PT is connected to a PLC or other controller Do not use the function switches or switches on the touch panel as input switches that may cause injury or damage property Install monitoring circuits or other devices in output signals that may result in serious accidents Construct the system so that switching of important operations is performed in devices outside the PT For devices and components connected to the PT that affect safety use appropriate products meeting the required safety level and safety category System safety and the appropriate safety category must be evaluated for the entire system Consult a certified third party organization to determine the appropriate safety category It
10. is the user s responsibility to ensure that system safety adheres to relevant standards Connect the emergency stop switch and enabling switch on the PT so that they function according to stop category 0 or 1 described in IEC EN 60204 1 There are two types of switches on the PT a red one for use as an emergency stop switch and a gray one for use as a stop switch Use each of these for its intended purpose When using a PT with a red emergency stop switch attach the cable from the system securely so it cannot be easily disconnected When using a PT with a gray stop switch in an application where the PT is detached from the system make sure that the emergency stop switch and the stop switch can be clearly distinguished Precautions for Safe Use eWhen unpacking the PT check carefully for any external scratches or other damage Also shake the Units gently and check for any abnormal sound e nstall or hand hold the NSH5 when operating it Do not operate the NSH5 on the floor or on a tabletop Do not let metal particles enter the PT when preparing the panel eUse power supplies with reinforced or double insulation and minimal voltage fluctuation for the NSH5 PT and for inputs to the PT such as emergency stop switches enable switches functions switches and station detection The power supplies must be capable of maintaining stable outputs for momentary power interruptions in the inputs to the power supplies of up to 10 ms
11. nges in temperature Locations subject to temperatures or humidity outside the range specified in the specifications Locations subject to condensation as a result of high humidity Locations subject to splashing chemicals or solvents Locations subject to oil splashes Locations subject to corrosive or flammable gases Locations subject to strong shock or vibration Locations outdoors subject to direct wind and rain Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight eTake appropriate and sufficient countermeasures when installing sys tems in the following locations Locations subject to static electricity or other forms of noise Locations subject to strong electromagnetic or magnetic fields Locations close to power supply lines Locations subject to possible exposure to radioactivity Compliance with EC Directives 1 This product is EMC compliant when assembled in a complete PLC system of the specified PLC Series Refer to the applicable manual for grounding cable selection and any other conditions for EMC compliance NSH5 Series Hand held Programmable Terminal Operation Manual Cat No V090 2 This is a class A product It may cause radio interference in resi dential areas in which case the user may be required to take adequate measures to reduce interference E Operating Temperature 0 to 40 C E Special Cable Specifications The following table lis
12. or otherwise subjected to excessive shock The battery may leak if it is used eCommercially available USB hubs and the recommended USB hub do not necessarily have the same general specifications as the NSH5 and may not function properly if used in environments subject to static elec tricity or other forms of noise When using a USB hub take sufficient measures to prevent static electricity and other forms of noise or do not install the PT in an environment subject to such noise Do not disassemble or short circuit the battery eThe backlight in the PT cannot be replaced by the user Contact your OMRON representative for backlight replacement ePeriodically check the installation conditions in applications where the PT is subject to contact with oil or water eWater and oil resistance will be lost if the front sheet is torn or is peel ing off Do not use the PT if the front sheet is torn or is peeling off eThe Rubber Packing will deteriorate shrink expand or harden depending on the operating environment Inspect and replace the Rubber Packing periodically elf the brightness of the backlight on the PT is reduced the display and RUN in dicator may be very dark Do not reduce the brightness of the backlight so far that the display and RUN indicator cannot be seen This applies to lot numbers 3073 and later Operating Environment Precautions Do not install the PT in any of the following locations Locations subject to rapid cha
13. sure that the device is free from damage eWhen mounting the battery be sure to use the correct battery and mount it correctly eThe backlight contains mercury for PTs with lot numbers before 3073 Do not dispose of the PT together with other waste to be sent to a dis posal site Dispose of the PT according to local ordinances as they ap ply Do not turn OFF the power supply to the PT while downloading or up loading screen data or system programming The screen data and system programming may become corrupted Secure the PT s cable at the control panel when connecting it to the control panel Be sure not to trip over the cable when moving around while holding the PT eUse safety circuits that are capable of detecting shorts in the emer gency stop switch and enable switch eWhen using the NSH5 use the lefthand belt or use a commercially avail able neck strap If the NSH5 falls injury or device damage may occur ePeriodically inspect for loose cables or other cable problems eConfirm the safety of the system before turning ON or OFF the power supply or before pressing the reset button eAfter changing the settings of the DIP switch always turn the power supply OFF and ON or reset the PT Do not operate a touch switch using a screwdriver or other tool eTo ensure safety when using numeral input functions set the upper and lower limits for the input value Dispose of any battery that has been dropped on the floor
14. the Special Cable NSHS Funetion switches Four NO contacts output to external devices Special Cable X F2 L F6 faa Ft F2 Fe F7 i PLC PLC PLC PLC i i NSH5 series Operation Manual NS series Programming Manual CX Designer User s Manual SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the sys tems machines and equipment with which it will be used Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM See also product catalogs for Warranty and Limitations of Liability Local support office OMRON OMRON Corporation Industrial Automation Company Tokyo JAPAN Contact www ia omron com Regional Headquarter OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL
15. ts the Loose wire D Sub and UL standard Spe cial Cable models Cables are provided for both RS 232C and RS 422A depending on the serial communications protocol Communi Serial Cable type cations commu Model Length connector nications Loose wire 9 pin D Sub RS 232C NSH5 232CW 3M 3m D Sub Loose NSH5 232CW 10M 10m wires RS 422A NSH5 422CW 10M 10m UL Loose RS 232C NSH5 232UL 3M 3m Standard wires NSH5 232UL 10M 10m relay cable Loose wires RS 422A NSH5 422UL 10M 10m Note 1 The Special Cable is sold separately 2 Always use a UL standard cable for applications requiring UL certification E Cable Dimensions UL standard Models RS 232C NSH5 232UL 3M 10M rA Ne 232C Relay cable us toh 30 V7 ong D8 2 1 000 i Loopback connector TONE OE 80x10 89 300 10 00 F a CE C a N T 4 7 i _ FERTA s Jei pa E m E a a ONS i f 0a EE cna 00 Gal ee L E cn7 20010 KAL Loopback connector Rd ea P47 When connecting to an OMRON PLC the control signals must be looped back Connect loopback connectors to CN8 and CN7 UL standard Models RS 422A NSH5 422UL 10M 10 80 0 4 _O_ Loose wire D Sub Cable cnt 180 ji 09 CN2 o9 CNS co No 5 No 10 j i ji No 1 No 6