1. e Accommodates an additional plug on piggyback interface such as the Nx56 64 e Includes an elastic store and controlled frame slip permitting loop timing on the network interface as well as on the DSX 1 interface e Provides timing for the TSU 100 600 as an option e Displays menu options for easy configuration e Executes an extensive self test Interfaces The DSX 1 Passthru option module has the following interfaces DSX 1 per ANSI T1 102 Interface connectors RJ 48C and DB 15 e Alternate Mark Inversion AMI or Bipolar Return to Zero B8ZS coding ESF or SF D4 formatting independent of T1 facility interface Line length up to 655 feet e Line loopback front panel remote inband 2 DSX 1 Passthru User Manual 61200055L1 1D Chapter 1 Introduction DSX 1 Passthru Option Module Specifications 61200055L1 1D The DSX 1 Passthru option module conforms to the following specifications DSX 1 Interface Line Rate Capacity Line Codes Framing Options Line Length Clock Source Tests Connectors Per ANSI T1 102 1 544 Mbps 1 to 24 DSOs can be user configured contiguous or non contiguous AMI B8ZS ESF per ANSI T1 403 and AT amp T Publication TR 54016 D4 per AT amp T Publication 62411 Up to 655 ft in 110 ft steps Allows PBX to be master timing source Power on circuit self test line loopback Port loopback internal toward MUX DB 15 female RJ 45C DSX 1 Passthru User Manual 3 Chapter 1 In
2. 055L1 1D PORT UTIL a submenu of the TSU 100 600 main menu item Utilities UTIL displays the current software information for each port installed in the unit This information is required when requesting assistance from ADTRAN Customer Service or when updates are needed When PORT UTIL is displayed place the cursor on it and press Enter to display the first available port Scroll to display 1 1 DSX1 PT and press Enter to activate The unit displays the option module name and the software version installed Press Cancel to exit or select another port Port Test a submenu of the TSU 100 600 main menu item Test activates tests of the selected data ports Selecting the DSX 1 Passthru displays two loopback tests available for this option module When Port Test is displayed place the cursor on it and press Enter to display the first available port Scroll to select 1 1 DSX1 PT and press Enter to activate DSX 1 Passthru User Manual 15 Chapter 3 Operation Loopback Loopback activates the loopback function on the DSX 1 Passthru module All ports contain a local loopback toward the DTE and a port loopback toward the NI as explained in the section Function Description of the TSU 100 600 User Manual Line Loopback On the DSX 1 Passthru module Line Loopback causes data received at the DSX 1 interface to be looped back toward the DTE PBX achieving a local loopback Port Loopback The Port Loopback is internal and loops all dat
3. ADRAN DSX 1 Passthru Option Module User Manual 61200055L1 1D January 2005 Table of Contents Table of Contents Chapter 1 Introduction ProductiOverview 0 fies ein MM as el ae eee AL bled ah en A auc 1 Functional description seoser ioin i R sat esdeveecdeeviwedectencies 1 ILERE UE nr S ETE EE EENE A E EAT A 2 Interfaces sin ee E E cite ce ee ea eee 2 DSX 1 Passthru Option Module Specifications 0 ccccceseesecsscesceeecesceeeeeseeseeeeceeseeeeensees 3 Physical Description 42e tin ee aennnen teinte R latest dre t 4 Chapter 2 Installation Wnpack and Inspect 54e alate rs EE MN ne PR eh AR RAR RTS ES 5 ADTRAN Shipments Include ss 5 Provided Dy Customer eroe n E E E eae eee ees 5 Installing the Option Module ss 6 Placement ofthe Option Module ki AS Ra ith i a Ann tete 6 Power Connection fu ess cakes ed oes east E ha a a Ends CHU nd EET 6 WADE nn nee PURE ST TE AR ee eee ee 7 Power Up Testing and Initialization ss 8 Succ ssful Self Tests 24e Sheth eee RAR eat ase ales 8 Earl d Selt Dest ii sca nan nn ne An E EE E ees 9 Operation Alarms ins SR aero aise eet 9 Warranty and Customer Service esse 9 Chapter 3 Operation VET ATEN CSP nr ER TP AEE PRR 11 Menu Strueture enetimer ae A estes heh eee eee eee ee 11 Menu Operations nr nt nn eee a an rene eed elven 11 Passthru Menu Items iii 13 Port Status screen a ER E ER e une AE dence GAE E 13 CRC ENEE E EA E AA ATATA EE TE EIES t rte 13 BPV a eae R e ter E
4. E E E E er eee 13 D C O EEEE haces EE OET E ANRT EONTR 14 FER men NT IE E E E ERER RA ET 14 Port Configuration PORT CONFIG ss 14 Format nent re nee der era nn nee nine re relie nn eee 14 COEUR en ages het wth ak Rees 14 Yellow CYEL Alarme abscess cides ennemie cds Absentee ieee 14 Line Length ft erene n sde ett RTE Rs detente ok ate 14 61200055L1 1D DSX 1 Passthru User Manual i Table of Contents In Band Loopback INBAND LPBACK 0 cececcecseseecesceeseceeesaeeesenseensenseens 14 Clock Source nomination eee eee tenes ca e iaie 15 Port Utility PORT UTD Ae iste gent nain date dette al ae his 15 Pore Tests Red en Tepe See a Ree Rea Sed Tl ph ee 15 TOO PD ACK ententes ee a ent dh nie E 16 TSU Features Used with Passthru Options cccceccesseeseceseeseceeceseeeceseeeeeeeceseeeeecaeeneeeneeenees 17 Factory RESIOTE te RE Sess chess tetbuensaeseed a a ein cine Goavotaaye A elite 17 R n Self Test 55e mener vines micah dite erie cee ee eee 17 Appendix A Passthru Failure Messages Failure Messages at Power Up erreneren o ne Rire nee eases 19 Passthru Alarm Messages 19 List of Figures Figure 1 1 DSX 1 Passthru Option Module oo ececsseecseeeeecneeseeseceeeseeeessecaeeeeeeceaeceseesenenee 4 Figure 2 1 Installing Option Module ss 6 Figure 3 1 TSU 100 600 Main Menu serrer 12 Figure 3 2 Port Status Display sise 13 Figure 3 3 Diagranrof LoopbackS 4238 diam naine md eur arate 16 List of Tables Table 2 1 Pinout Conn
5. IP Send Data Towards the DTE PBX 3 UNUSED 4 R RXDATA RING Receive Data from the DTE PBX 5 T RXDATA TIP Receive Data from the DTE PBX 6 7 8 UNUSED Table 2 2 Pinout Connectors for 15 Pin D Shell Interface PIN NAME DESCRIPTION 1 T RXDATA TIP Receive Data from the DTE PBX 2 FRAME GROUND 3 T1 TXDATA TIP Send Data Towards the DTE PBX 4 FRAME GROUND 5 6 7 8 UNUSED 9 R RXDATA RING Receive Data from the DTE PBX 10 UNUSED 11 R1TXDATA RING Send Data Towards the DTE PBX 12 13 UNUSED 14 15 61200055L1 1D DSX 1 Passthru User Manual 7 Chapter 2 Installation and Operation POWER UP TESTING AND INITIALIZATION The DSX 1 Passthru option module executes a self test during the power up sequence as described in the TSU 100 600 User Manual No initialization input is required Any previously configured setting for the DSX 1 Passthru module is restored automatically upon power up Successful Self Test The green OK LED located with the module LEDs on the front panel illuminates when a successful self test is completed and the configuration is successfully restored Refer to Front Panel Operation in the TSU 100 600 User Manual Failed Self Test If the DSX 1 Passthru module fails one or more of the self tests a message is displayed in the LCD during power up Refer to TSU 100 600 User Manual for more information Specific failures of the DSX 1 Passthru module are identified in the alarm listings in the Appendix A Pass
6. L1 1D The DSX 1 Passthru menus are accessed from and operated the same as menus for the TSU 100 600 The DSX 1 Passthru items are submenu choices of the TSU 100 600 four main menus as shown in Figure 3 1 For information on Factory Restore and Run Self Test refer to TSU FEATURES USED WITH PASSTHRU OPTIONS on page 3 17 The DSX 1 Passthru menu items are e Port Status e Port Configuration e Port Utility e Port Test Port Status a submenu of TSU 100 600 main menu item Status displays error information about the DSX 1 interface There are four information fields See Figure 3 2 An asterisk indicates an item is active ven NA Figure 3 2 Port Status Display CRC An asterisk is displayed under the CRC if there are CRC errors in extended superframe format ESF mode If the DSX 1 is configured for D4 Frame format the LCD displays n a BPV An asterisk is displayed under the BPV if the DSX 1 is detecting bipolar violations DSX 1 Passthru User Manual 13 Chapter 3 Operation XS0 An asterisk is displayed under the XS0 if the DSX 1 Passthru is detecting excessive zeroes Eight consecutive zeroes in B8ZS or 16 consecutive zeroes in AMI FER An asterisk is displayed under the FER if the DSX 1 Passthru is detecting frame bit synchronization errors Port Configuration PORT CONFIG PORT CONFIG a submenu of TSU 100 600 main menu item Configuration is used to configure the DSX 1 Passthru option
7. User Manual shows a complete menu diagram Menu Operation 61200055L1 1D An option module must be selected from the listing in one of the Port menu options before its menus are applicable With the cursor on one of the Port menu items press Enter to display a list of the currently installed option modules To activate menus for the DSX 1 Passthru option module scroll through the list to display 1 1 DSX PT and press Enter Once the option module is selected the DSX 1 Passthru menus appear as a subset of and operate the same as menus for the TSU 100 600 With the cursor on one of the TSU 100 600 four main menu choices press Enter or a menu number to display the first two submenu items DSX 1 Passthru User Manual 11 Chapter 3 Operation Use the up and down arrows to place the cursor on the desired item and press Enter to display the first two submenu choices 1 NI PERF REPORTS 1 STATUS 2 NI ERRORS 3 ACTIVE ALARMS 1 NETWORK NI 4 VIEW HISTORY 2 UNIT 5 PORT STATUS 3 MAP XCHNG 2 CONFIG 4 MAP IN USE A B TSU 100 5 DSO MAP A MAIN MENU 6 DSO MAP B 1 ENTER PASSCODE 7 PORT CONFIG 2 TIME DATE 3 UTIL 3 FACTORY RESTORE 4 REINIT UNIT 1 NETWORK TESTS 5 UNIT ID 4 TEST 2 RUN SELF TEST 6 SOFTWARE REV 3 PORT TESTS 7 PORT UTIL 4 CANCEL TEST Figure 3 1 TSU 100 Main Menu 12 DSX 1 Passthru User Manual 61200055L1 1D Chapter 3 Operation PASSTHRU MENU ITEMS Port Status 61200055
8. a mapped to the DSX 1 Passthru back toward the network interface on the controller Loopback when used in conjunction with an external bit error rate tester BERT driving the network interface exercises the entire data path from the network interface NI controller through the DSX 1 Passthru option module and back out the network interface controller See Figure 3 3 To deactivate Loopback select None under the 1 1 DSX1 PT submenu TSU 100 DSX 1 Passthru Network Interface Interfaces Sa i NI D psx 1 PBX Controller ye PORT LINE LOOPBACKS Also called Secondary Interface SI Figure 3 3 Diagram of Loopbacks DSX 1 Passthru User Manual 61200055L1 1D Chapter 3 Operation TSU FEATURES USED WITH PASSTHRU OPTIONS In addition to the DSX 1 Passthru module menu items two additional menu items of the TSU 100 600 may be operated in conjunction with the DSX 1 Passthru option module These are Factory Restore and Run Self Test Factory Restore Factory Restore a submenu of the TSU 100 600 main menu item Utilities UTIL restores the factory installed default setting for all DSX 1 Passthru option module parameters When Factory Restore is displayed place the cursor on it and press Enter to restore preset factory defaults and return to the main TSU 100 600 menu Run Self Test Run Self Test a submenu of the TSU 100 600 main menu item Test exec
9. e User Manual Provided by Customer The customer must provide the following e Cable for connection to PBX either DB 15 or RJ type 61200055L1 1D DSX 1 Passthru User Manual 5 Chapter 2 Installation and Operation INSTALLING THE OPTION MODULE Power to the TSU 100 600 should be off when installing the UT DSX 1 Passthru module Placement of the Option Module Figure 2 1 represents the action required for proper placement of the option module Remove cover plate from the TSU 100 600 rear panel 2 Slide the option module into the rear panel until it is positioned firmly against the front of the TSU 100 600 3 Tighten the screws at both edges of option module lt 7 Cover Plate TSU 100 600 amp Option Module Figure 2 1 Installing Option Module Power Connection Each DSX 1 Passthru module derives power from the base TSU 100 600 unit Power to the TSU 100 600 is supplied by a captive 8 foot power cord Wiring The DSX 1 Passthru module offers two connectors for interfaces Only one is used in an installation and each is connected to the same interface 6 DSX 1 Passthru User Manual 61200055L1 1D Chapter 2 Installation and Operation The required wiring connections are Connector Type USOC RJ 48C Part number AMP 555164 1 Table 2 1 Pinout Connectors for Eight Position Modular Jack Interface PIN NAME DESCRIPTION 1 R1 TXDATA RING Send Data Towards the DTE PBX 2 T RXDATA T
10. ectors for Eight Position Modular Jack Interface essees 7 Table 2 2 Pinout Connectors for 15 Pin D Shell Interface oo eee eeeeecseceeeeeseeeeeeeerenee 8 Table 3 1 Port Configuration Parameters ccceccccsecsesecssesseceeceseeseeeeceseeeeeeseeseecaeeaeeeeaees 15 ii DSX 1 Passthru User Manual 61200055L1 1D Chapter1 Introduction PRODUCT OVERVIEW The DSX 1 Passthru module is one of the secondary interface option modules available for use with the ADTRAN TSU 100 600 The DSX 1 Passthru option module should be selected to provide DSX 1 access for PBXs or other equipment that use a DSX 1 interface When used with a PBX this interface permits the combination of voice and data in a single T1 stream The user can select the bandwidth allocation for the DSX 1 Passthru module FUNCTIONAL DESCRIPTION The DSX 1 Passthru module is designed to fit in the option slot of the TSU 100 600 and is subject to its operation and control The DSX 1 Passthru is configured from the front panel of the TSU 100 600 or by an external personal computer PC program The internal menus for its configuration are a part of the DSX 1 Passthru module and are automatically installed when the module is plugged into the unit 61200055L1 1D DSX 1 Passthru User Manual 1 Chapter 1 Introduction Features The DSX 1 Passthru option module has the following features e Operates using 1 to 24 DSOs e Operates as a drop and pass on or as a standard pass on module
11. module When PORT CONFIG is displayed place the cursor on it and press Enter to activate Scroll to display the desired configuration and activate by pressing Enter The unit displays the first of six submenu items Table 3 A identifies the available selections for Port Configuration Continue with standard operating procedures Format Format sets the frame format for the DSX 1 Passthru Code Code sets the data code for the DSX 1 Passthru Yellow YEL Alarm YEL Alarm enables and disables the transmitting of yellow alarms Line Length ft Line Length allows selection of the proper output level for the DSX 1 interface based on the length of the interface cable In Band Loopback INBAND LPBACK In Band Loopback sets the DSX 1 Passthru to accept or reject in band loopup and loopdown codes per ANSI T1 403 specification which may be sent to the card over the DSX 1 interface This loopback is a line loopback DSX 1 Passthru User Manual 61200055L1 1D Chapter 3 Operation Clock Source Clock Source selects the clock source for transmission toward the PBX or device connected to the DSX 1 Passthru module Table 3 1 Port Configuration Parameters MENU ITEM PARAMETER CHOICES Format D4 ESF Code AMI B8ZS Yellow Alarm Enable Disable Line Length 1 110 110 220 220 330 330 440 440 550 550 655 gt 655 In band Loopback Accept Reject Clock Source Network NI Secondary SI Port Utility PORT UTIL Port Test 61200
12. thru Failure Messages Operation Alarms The red ALARM LED with the module LEDs on the front panel illuminates when an alarm condition is detected 8 DSX 1 Passthru User Manual 61200055L1 1D Chapter 2 Installation and Operation WARRANTY AND CUSTOMER SERVICE 61200055L1 1D ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specifications or if it fails while in service For detailed warranty repair and return information refer to ADTRAN s Equipment Warranty Repair and Return Policy Procedure A Return Material Authorization RMA is required prior to returning equipment to ADTRAN For service RMA requests or more information contact one of the numbers on the last page of this manual DSX 1 Passthru User Manual 9 Chapter 2 Installation and Operation 10 DSX 1 Passthru User Manual 61200055L1 1D Chapter Operation OVERVIEW The DSX 1 Passthru module is controlled as part of the TSU 100 600 using the same methods as described in the user manual Refer to the TSU 100 600 User Manual for descriptions of the front panel indicators and buttons Menu Structure When an option card is installed in the TSU 100 600 the unit adds it to the list of selectable options under the Port menu items These menu items are shaded in the limited overview of the TSU 100 menu shown in Figure 3 1 The appendix TSU 100 Complete Menu of the TSU 100 600
13. tions Support Please contact your local distributor ADTRAN Applications Engineering or ADTRAN Sales Applications Engineering 800 615 1176 Sales 800 827 0807 Post Sale Support Please contact your local distributor first If your local distributor cannot help please contact ADTRAN Technical Support and have the unit serial number available Technical Support 888 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed Technical Support will coordinate with the Customer and Product Service CAPS department to issue a Return Material Authorization RMA number For information regarding equipment currently in house or possible fees associated with repair contact CAPS directly at the following number CAPS Department 256 963 8722 Identify the RMA number clearly on the package below address and return to the following address ADTRAN Customer and Product Service 901 Explorer Boulevard Huntsville AL 35806 2807 RMA
14. troduction PHYSICAL DESCRIPTION The DSX 1 Passthru is an option module which plugs into the option slot in the rear of the TSU 100 600 See Figure 1 1 Se E EE Figure 1 1 DSX 1 Passthru Option Module A r PASS THRU KA PORT X 1 osx 1 The DSX 1 Passthru rear panel includes a plastic plug over a cutout for a V 35 connector This allows a V 35 Nx56 64 interface plug on card part number 1200053L1 to be added to the DSX 1 Passthru module The PORT X 1 identification on the rear panel is linked to the port numbering philosophy of the TSU 100 600 product family The X represents the slot number and the 1 indicates the port number For the TSU 100 600 application there is only one option slot Therefore the port designation for the DSX 1 Passthru port is 1 1 If added the Nx56 64 port designation would be 1 2 These port numbers appear in the front panel LCD menu displays 4 DSX 1 Passthru User Manual 61200055L1 1D Chapter2 Installation and Operation UNPACK AND INSPECT Carefully inspect the DSX 1 Passthru module for any shipping damage If damage is suspected file a claim immediately with the carrier and then contact ADTRAN Customer Service If possible keep the original shipping container to ship the DSX 1 Passthru module for repair or for verification of damage during shipment ADTRAN Shipments Include The following items are included in the ADTRAN shipment e DSX 1 Passthru Option Module
15. utes both the DSX 1 Passthru internal test and the TSU 100 600 internal test The TSU 100 600 internal test is the same self test executed upon power up The results of the self test are displayed in the LCD For additional information on Self Test refer to the TSU 100 600 User Manual When Run Self Test is displayed place the cursor on it and press Enter to execute the test The unit continuously changes the display in the LCD window until all test results are shown 61200055L1 1D DSX 1 Passthru User Manual 17 Chapter 3 Operation 18 DSX 1 Passthru User Manual 61200055L1 1D Appendx A Passthru Failure Messages FAILURE MESSAGES AT POWER UP The following messages indicate a probable component failure on the DSX 1 Passthru module EPROM CS EPROM checksum error RAM ERR Static RAM error PASSTHRU ALARM MESSAGES The following messages indicate an alarm condition on the DSX 1 Passthru module Red Alarm Not able to frame data coming from the DSX 1 interface sometimes referred to as out of frame OOF Yellow Alarm Remote alarm indicator RAI being received from the DSX 1 interface Blue Alarm Receiving unframed all 1s from the DSX 1 interface alarm indicator signal AIS Loss of Signal No signal detected from the DSX 1 interface 61200055L1 1D DSX 1 Passthru User Manual 19 Appendix A Passthru Failure Messages 20 DSX 1 Passthru User Manual 61200055L1 1D Product Support Information Pre Sales Inquiries and Applica