Home
8ZED Pure Sine Wave Inverter / Charger User Manual PDF
Contents
1. Charging i Current A CC Step CV Step Floating Step 2 3 Digital Display For high wattage inverter with charger such as 1000W and higher the front panel has digital display The Digital Display Shows the DC Voltage input that the unit senses at its terminals and the percent of the output wattage Protection Input protection A Battery polarity protection lf the battery input is connected in reverse polarity the internal fuse of the inverter will blow and the unit should be send back for repair and resetting B Battery Under Voltage shutdown When the battery voltage is lower than the preset value the unit will automatically terminate the output and thus protect the battery from damage C Battery Over Voltage Protection When the battery voltage is too high the unit will automatically terminate the output and the built in buzzer will be activated to inform the user After bypassing the OVP condition the unit should be repowered ON to resume operation ZI WARNING Choose suitable batteries that are compatible with the rated input DC voltage of the inverter If the input DC voltage is too low eg using 12V DC battery bank for 24V DC input models the inverter cannot be started up properly If the input DC voltage is too high eg using 48V DC battery bank for 24V DC input models the inverter will be damaged 3 2 Output protection The display panel will show failure status using red LED indicators when
2. Make sure that suitable wires are chosen based on the current rating Too small of a cross section will result in overheating and could be dangerous B Requirements for Installation The unit should be mounted on a flat surface or holding rack with suitable strength In order to ensure the lifespan of the unit please refrain from operating in environments of high dust or moisture Please make sure that ventilation is not blocked and avoid long term operation within high ambient environment or continuous overloading There should be no barriers within 15cm of the ventilation holes Inverter ral C AV Important notice on output load This unit can power most equipment that needs an AC source however for certain types of load the unit may not work properly 1 Since inductive loads or motor based equipment need a large start up current 6 10 times the rated current the inverter may not start up successfully with these kind of load 2 When the equipment output is capacitive or rectified such as switching power supply it is suggested to operate this equipment at no load or light load during start up To ensure smooth power ON you should increase the load only after the unit has started up 5 Failure Correction Notes The unit should be serviced by a professional technician Any improper usage or modification may damage the unit or result in shock hazard If you are not able to clear the failure condition please contact us
3. unit is faced with abnormal operating conditions This alerts the user to potential problems 1 Over Temperature Protection When the internal temperature is higher than the limit value OTP will activate and automatically shut down the unit Users should wait for at least 30 minutes before restarting the unit 2 AC Output Abnormal Protection When the AC output voltage of the inverter is too low or too high the unit will turn off and should be restarted again 3 AC Output Short Circuit Protection When a short circuit situation occurs at the output side of the inverter or the loads increase greatly in a short period of time the unit will turn off and should be restarted again 4 Battery Voltage Abnormal Protection When the battery voltage is too high or too low this protection will be activated The inverter will auto recover after the battery voltage goes back to a safe level and a user restart is not required 5 Over Load Protection When the output is overloaded the inverter can still continuously provide power for several minutes After that if the overload condition is not removed overload protection will activate When the overload is too high the overload protection will be activated instantly For these overload protections once activated the unit must reset to recover 4 Installation amp Wiring A Wiring for Batteries Wire connections should be as short as possible and less than 1 5 meter is highly recommended
4. 8ZED Pure Sine Wave Inverter with Charger SIPA ZED COM Instruction Manual Index 1 Safety Guidelines 2 Introduction 3 Protection 4 Installation amp Wiring 5 Failure Correction Notes 1 Safety Guidelines Please read through this manual before assembling inverter charger e Risk of electrical shock and energy hazard e All installations should be examined by a qualified technician e Warranty will be void if case of the unit is removed or tampered with e Do not install unit in places with high moisture or near water e Do not install unit in places with high ambient temperature under direct sunlight or near flame source e Only connect batteries with the same brand and model number in one battery bank Using batteries from different manufacturers or different capacity is strictly prohibited and will void warranty e Never allow a spark or flame in the vicinity of the batteries because it may generate explosive gases during operation e Ensure air flow from the fan is not obstructed at both sides front and back of the unit Please allow at least 15cm of space e Do not stack any objects on unit AN gt WARNING Batteries will deteriorate with age It is recommended to execute regular battery maintenance at least once a year Deteriorated batteries should be changed by a qualified electrician or the failed batteries may cause fire or other hazards Donjt Keep away from Keep away from Donjt stack on Keep good di
5. or any of our distributors for repair service For Warranty and Support 8ZED com Status Possible Reasons Ways to Eliminate Abnormal input Check the DC input source Make sure the voltage is within the required range Over temperature Make sure that the ventilation is not blocked or the Protection ambient temperature is too high De rate the output usage or reduce the ambient temperature No AC output Overload protection Make sure the output load does not exceed the rated value or the instantaneous start up current is not too high for inductive or voltage capacitive loads Short circuit Make sure the output is not overloaded or a short protec H00 Circuit exists Discharging Batteries are Replace the batteries period of aged or broken batteries is too short Battery capacity Reconfirm the specification and enlarge the as battery capacity as suggested Fan does Clog with foreign objects Remove the foreign objects not Spin Malfunction of the fan Repair required Take it to a qualified service person when service or repair is required For more inverter FAQ s 8ZED com
6. sassemble moisture fire or high the inverter ventilation temperature 2 Introduction e This unit is a DC AC Pure Sine Wave Inverter with charger drawing power from the battery bank and converting it into AC voltage e thas built in three stage battery charger and automatic transfer between inverter power and incoming AC utility power e General applications include PC IT Electronics Vehicles Yachts Home Appliances Motors Power Tools Industrial Control Equipment AV Systems and more 2 1 Features e LED digital display showing input DC voltage and percentage of power e LED indicators showing charger is charging and full status e Full protection including short circuit over voltage under voltage over temperature over load e Input and output isolated e With battery charger e Transferring time 20ms to ensure the power supply uninterrupted e Cooling mode Thermal Fan e Remote Control On Off 4 meter cable Power inverter e Input 12V DC e Output 220V 240V AC 50Hz e Pure sine wave output THD lt 3 0 High efficiency up to 90 e Can be used for most electronic products with AC input Battery charger e Input 220V 240V AC 50Hz e Output 12V DC e Charge Current 15A e Completely automatic battery charging CC constant current CV constant voltage and float stage 2 2Charging Mode 3 stage Step 1 CC Constant Current Step 2 CV Constant Voltage Step 3 Floating A Charging ii itag e V a we r