Home

USER MANUAL RA 18 CONTROL PANEL

image

Contents

1. The sensor is fitted on the center line of the heater 40 mm from ceiling OLET 19 Absolute measurement must not be exceeded or undershot Safety clearances between the bottom of the sauna heater and a wall Fixing the sauna heater on the floor NOTE fixing of two 2 legs 2 Heaters Middle installation T leg Floor Y RZ fixing Metal screw fastener A A Adi Sens zes cS j F mm S y 770 ee A A 60 60 l lt q Pa I y H 1900 OLET 19 NOTE If the sauna heater is installed further than 60mm off a wall ora corner the installation method is always middle installation The thermostat must be installed in the ceiling as per instructions Sensor placement in the sauna room with sauna heater type 1120 0405 SKLW DE The sensor is fitted on the center line of the heater 40 mm from ceiling Measurements are minimum mm if nothing else is stated Corner and wall installation OLET 19 i v 60 i N OLET 19 E LUSK x Bee NOTE Absolute measurement Fixing the sauna MONS heater to the floor oe Image NOTE Fixing of E two 2 legs Middle installation o Sauna i H heaters leg l jam i A A Floor tem X Metal OLET 19 4 an i fastener 7 mm amp e N i a Adjustable A leg p e 60 60 rel Ii Pid The thermostat must be installed within the d
2. Increase setting Approve changes in settings start heater Decrease setting Control panel activation deactivation On Off button On Off button Starts and stops functions When the equipment is active pressing this button will stop all functions and display will turn off When button is pressed when the equipment is in passive mode display off it will activate the control OK button Approves changes in settings or moves to the next setting depending on function mode Plus button Increase setting Minus button Decrease setting Activates a relay on the circuit board Electrical connectors for lighting are marked with a N and a light symbol on the connector strip voltage is 230 VAC max 100W A led is activated next to the button on the control panel when lights are activated Function times and settings preset time function time 0 23 hours 0 6 hours Control panel functions 1 Press the On Off button of the control panel Both displays of the control unit will turn on and the panel switches to setting mode If you get no response when pressing the On Off button please check the position of the main switch in the sauna heater The correct position is 1 2 The upper display shows three bars and the lower display time display flashes digits 0 00 which indicates that the preset time can be changed The default value of the preset time is 0 00 i e
3. gt max 750 mm Sensor OLET 19 placement with different heaters Sensor placement in the sauna room with sauna heater type 1707 0405 SKSG DE The sensor is fitted on the center line of the heater 40 mm from ceiling Sensor OLET 19 40 mm min mm 143 145 J The specified clearances are minimum clearances except for which marks an absolute measurement The sensor is fitted on the center line of the heater Sensor placement in the sauna room with sauna heater type 1712 0405 SKSM DE The sensor is fitted on the center line of the heater 1712 040520 SKSM DEW 40 mm from ceiling mm Absolute min 1900 Sensor placement in the sauna room with sauna heater type 1116 0405 SKLR DE Absolute measurement 135 From the corner Sensor OLET 19 min 1900 a Oo e lo N x E Ne Sensor placement in the sauna room with sauna heater type 1118 0405 SKLT DE The sensor is fitted on the center line of the heater 40 mm from ceiling Senosr OLET 19 min mm Absolute Sensor placement in the sauna room with sauna heater type 1118 0405 SKLT DE Measurement is minimum mm if nothing else is stated Corner and wall installation 40 OLET 19 mm H 1900 l 1130 Rocher 800 Ring
4. control panel switches to active mode after the preset time bathing temperature and bathing time have been set In the active mode the sauna heater functions as follows e If the preset time is default 0 00 i e not changed in the setting mode the sauna heater will turn on immediately and the temperature display shows the current temperature of the sauna room while the time display shows the remaining bathing time e If the preset time is not 0 00 i e the default setting has been changed in the setting mode the control panel switches to the preset mode In this mode the upper display shows three bars and the lower display shows the remaining preset time The dot between hours and minutes in the time display flashes to indicate that the preset mode is activated Once the preset time has elapsed the sauna heater will turn on and start heating up Some useful tips e The sauna heater control panel can be switched off at any time by pressing the On Off button e You can speed up the selection of setting values by keeping the button or pressed e If the settings stored in the memory bathing temperature and time are applicable you can turn the sauna heater on simply by pressing the On Off button of the control panel The control panel displays the settings and starts the sauna heater automatically if no buttons are pressed The control panel is able to display certain malfunctions The control panel is able to di
5. USER MANUAL RA 18 CONTROL PANEL Type 1601 18 General Control panel is intended to be installed next to the heater in the area outlined in the manual The control panel is compatible with the following heater models 1707 0405 SKSG DE 1712 0405 SKSM DE 1712 040520 SKSM DEW 1116 0405 SKLR DE 1118 0405 SKLT DE 1120 0405 SKLW DE Maximum heating time 6 hours Maximum preset time 23 hours Adhere to given installation measurements Heater and connection into the mains can only be carried out by an authorised person according to current electricity regulations NOTE Prior to switching the heater on ensure that the sauna room is ready for heating Persons with reduced physical and mental capacity sensory handicap or little experience and knowledge about how the device is operated e g children should only operate the device while supervised or according to instructions given by the persons in charge of their safety Make sure that children are not playing with the sauna heater 7014382 314 SYRA 23 D Control panel RA 18 Sauna room light control On Off Temperature display Desired temperature Setting mode Actual temperature Operating mode Time display Preset time Setting mode Desired bath time Setting mode Remaining bath time Operating mode Remaining preset time Preset mode
6. aanwijzing of de verpakking naar verwijst Het materiaal kan worden gerecycled op basis van de aangebrachte markeringen Door hergebruik van materialen of oude apparaten levert u een belangrijke bijdrage aan de bescherming van ons milieu Lever het afgedankte product af bij de inzamelplaats zonder saunastenen of het deksel van speksteen Voor vragen over de inzamelplaats kunt u contact opnemen met de gemeente Instructions pour la protection de l environnement Ce produit ne doit pas tre m l aux ordures m nag res en fin de vie Il doit tre d pos dans un centre de collecte pour le recyclage des appareils lectriques et lectroniques Le symbole appos sur le produit la notice d utilisation ou l emballage l indique Les mati res peuvent tre recycl es conform ment leur marquage En r utilisant recyclant les mati res ou en utilisant diff remment un vieil quipement vous contribuez consid rablement la protection de l environnement Attention ce produit doit tre d pos au centre de recyclage sans pierres et sans parement en st atite Veuillez contacter votre Municipalit pour connaitre le centre de recyclage 14
7. ashed area to the ceiling o above the sauna heater Sensor OLET 19 Sauna heater NOTE If the sauna heater is installed further than 60mm off a wall ora corner the installation method is always middle installation The thermostat must be installed in the ceiling 9 as per instructions Wiring diagrams 1234 A12345 B12345 Sy tt N tet Stromnetz Power input Saunavalo Bastu belysning Saunabeleuchtung Sauna light max 100W Ei toimintoa Ingen funktion Keine funktion No function S hk l mmityksen vuorottelu El forregling av annan el f rbrukare Signal kontakt Signal contact Ohjauskeskus Styrpanel Steuerger t Control panel Tuntoelin Sensor F hler Sensor RON on Connector strip Limiter Sensor cable Blue 4 Bide e j ass nen cacy 1 2 White 2 White 3 Red 3 Red 4 Yellow 4 Yellow Heater PCB OLEA 57 Communication PCB OLEA 83 O OIOJOIO OJOIOIOJO A12345B12345 1 Brown 2 Black 3 Green 4 Yellow Wiring diagrams Sensor Heater Sauna light 230V 100W Signal contact 230V No function RA 18 control panel with the Input 400V 3N RA 18 Midi control panel 11 RA 18 Control panel installation 1 First fasten the wooden base plate for control panel to the wall with the provided screws Make
8. onado Los materiales pueden reciclarse seg n las marcas que figuren en ellos Mediante la reutilizaci n o aprovechamiento de estos materiales o la reutilizaci n de equipos antiguos se contribuye de manera importante a la protecci n del medio ambiente Nota este producto debe entregarse en el centro de reciclaje sin las piedras de sauna ni la cubierta de esteatita Instructions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic devices The symbol on the product the instruction manual or the package refers to this The materials can be recycled according to the markings on them By reusing utilising the materials or by otherwise reusing old equipment you make an important contribution for the protection of our environment Please note that the product is returned to the recycling centre without any sauna rocks and soapstone cover Please contact the municipal administration with enquiries concerning the recycling place Instructies ter bescherming van het milieu Dit product mag aan het einde van de levensduur niet worden weggegooid via het normale huishoudafval In plaats daarvan moet het worden afgegeven bij een inzamelplaats voor het recyclen van elektrische en elektronische apparaten Dit is waar het symbool op het product de gebruiks
9. splay certain malfunctions that may arise while using the sauna These are the corresponding error messages E f Q Err 1 Overheating protection activated Err 2 Sensor malfunctioning Ecc Q Err 3 Serial traffic between the sauna heater and the control Er panel is not working t y These malfunctions must be repaired by a qualified technician Please contact the nearest authorised repair shop AR Placement of the control panel with different heater types The control unit must be installed on the dashed area 1 min and max measurements must be followed Placement of the control panel in the sauna room with sauna heater type min 600 mm min 300 mm max 750 mm max 600 mm Placement of the control panel in the sauna room with sauna heater type 1116 0405 SKLR _DE min 40 mm max 750 mm 1707 0405 SKSG DE 1712 0405 SKSM DE 1712 040520 SKSM DEW min 600 mm min 300 mm max 600 mm min 600 mm min 300 mm gt max 600 mm A Placement of the control panel in the sauna room with sauna heater type 1118 0405 SKLT _DE min 600 mm min 300 mm gt max 750 mm min 600 mm min 300 mm max 750 mm max 750 mm Placement of the control panel in the sauna room with sauna heater type 1120 0405 SKLW _DE
10. sure the base plate is placed within the allowable installation area for detailed instructions please refer to the sauna heater manual Use a builder s level to make sure the plate stays straight during installing 2 Place the control panel accurately on the wooden base plate and drill a 2 3 mm hole through the upper part of the casing Depth of the hole is not critical because the purpose of the hole is to merely assist driving the screw into the wooden base 3 Subsequently fasten the control panel onto the wooden base plate with screws Make sure the control panel is straight in relation to the base plate drill a hole through the lower part of the casing and fasten with screws 4 Before driving the screws tightly make sure the cable is not pressed between the control panel and the wooden base but securely placed in the intended groove 5 Setthe control panel frame in place by pressing with your hands 6 The frame is removed by pressing the four grooves in the frame with a small rod or screw driver and slightly twisting outwards Instrucciones de protecci n medioambiental Este producto no debe ser tratado como un residuo dom stico normal al final de su vida til sino que debe depositarse en el punto de recogida adecuado para el reciclaje de equipos el ctricos y electr nicos La presencia de este s mbolo en el producto en el manual de instrucciones o en el paquete indica lo anteriormente menci
11. the sauna heater turns on immediately after the bathing time and temperature have been set If you want the heater to turn on after a certain period of time you must set the time preset time each time you turn the control panel on 3 The preset time is changed by pressing or buttons If none of the buttons e is pressed in 5 seconds the current time in the display will be saved in the memory You can also save the setting by pressing OK NOTE The control panel remembers the preset time as long as the panel is in the active mode Once the preferred preset time has been set and accepted the control panel moves on to display the settings for bathing temperature and time The upper display starts flashing which indicates that the bathing temperature can be changed The bathing temperature is changed by pressing and buttons similarly to changing the preset time Once the time is changed save the setting by pressing OK or by waiting for 5 seconds The setting for bathing temperature remains in the control panel memory after switching it off 5 Next the lower display starts flashing which indicates that the bathing time can be changed The bathing time is changed by pressing and buttons similarly to changing the bathing temperature Once the time is changed save the setting by pressing OK or by waiting for 5 seconds The setting for bathing time remains in the control panel memory after switching it off 6 The

Download Pdf Manuals