Home

NT HD200

image

Contents

1. d For measurement launching click on OK with the access key The number of points selected and the parameter are displayed e To save your dataset click on Save with the access key 1 2 Automatic dataset An automatic dataset is composed of measuring points with interval of time a Click on OK or gt to enter sub function ae l b Select Auto with A and V Confirm wih OK vanua catasat c Select Name with A and W Confirm wih OK or Kk Enter dataset name with the arrow keys and A V Confirm wih OK d Enter dataset time and interval of time between 2 measurements by selecting Period with access key Select Duration or Interval with A and V Confirm wih OK Enter minutes and seconds with arrow keys and V from 1 minute to 24 hours for the duration and from 5 seconds to 10 minutes for the interval Confirm with OK e Select Start for dataset launching F Ce ont ae GN gi Le Se es eet en te e Fap Ng a oe e a i oo Automatic dataset 2 Launch a planned dataset A planned dataset is composed of several locations For each location the operator can enter a theorical value and a tolerance for the parameter to be controlled Planification must be made via the software a Click on OK or gt to enter into sub function b Select Planned with A and W Confirm wih OK c Choose dataset name with A and V Confirm wih OK d Select the location with A and V Confirm wih OK 3 Delete a
2. Relative humidity RH From 3 to 98 RH Accuracy repeatability linearity 0 1 RH Di hysteresis HT Absolute humidity g Kg From 0 to 600 g kg 1 5 RH from 15 C to 25 C 0 1 g kg Factory calibration uncertainty 0 88 RH e Temperature depandence 0 04 x T 20 RH if T lt 15 C or T gt 25 C Dew point Ta Fy From 50 to 80 C 0 6 of reading 0 5 C 0 1 C Ambient temperature Ca From 40 to 180 C 0 3 of reading 0 25 C 0 1 C Wireless or wire Pt100 probes see related datasheet 0 01 C All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with required compensation As per NFX 15 113 and the Charter 2000 2001 HYGROMETERS GAL Guaranteed Accuracy Limit which has been calculated with a coverage factor value of 2 is 2 88 RH between 18 and 28 C on the measuring range from 5 to 95 RH Sensor drift is less than 1 RH year The accuracy is expressed either by a deviation in C or by a percentage of the value concerned Only the bigger value is considered ll Introduction Top view Module connections mini Din C2 mini Din C1 connector connector Graphic display Battery level Memory status used ai gt i Y is 7e e bw a te Hour Value Unit Side view Power supply Channel connection USB port fo
3. gt to enter Select your backlit level from 0 to 9 or AUTO with A and V Confirm wih OK If you select AUTO the HD200 adjuts automatically the backlit according to the room brightness e Key locking This sub function allows to enable or disable the key lock Click on OK or gt to enter into sub function Select respectively ON or OFF with A and V inorder to enable or disable this function Confirm wih OK If the locking is enabled the code menu appears e Code This sub function allows to enter the security code Click on OK or and the code appears Enter the first digit of the code with A and V then move to the next one with B Confirm wih OK Downloading data See DataLogger 10 user manual chapter lll Read device page 6 V General informations Info menu This menu allows to view the serial number of instrument and firmware version Battery When battery indicator flashes it is recommended to change the batteries 1 Remove the front part at the back of the instrument 2 Remove batteries 3 Insert new batteries AA LR6 1 5V in accordance with proprer polarity drew inside the housing 4 Replace the front Maintenance KIMO performs calibration adjustment and maintenance of all your instruments to guarantee a constant level of quality of your measurements In regards of Quality insurance norms we recommend that the instruments are checked once a
4. KIMO INSTRUMENTS Pressure Temperature Humidity e Air Velocity e Airflow e Sound level Calibration HD 200 ER certificate Hy g r O me t er Table of contents Technical SPECIES AGIOS argasta aa a 4 Technical RL Rete 10 fac EE SDP Tee EE Il air ge 0 Tei gd en BEEN 5 BIS ie le EE LONG S EE EEN IK ge ele EE 7 MANU EEN H Probe Nen assa A Na NN Ng a Using wire probes and FH 8 Usmo wireless ele E 8 BUEN d Tei e AN E ET E E E EE AT AAE TA E E E E EA EAEE ROG PONB D Parameters aeran eet Ree EE IR dl ele te e ln te D elt BACK E 11 OWN EE V General NFOPMABTION ccccccccssssscssscssssesssssssssssscessensessenececenceeeceeeeeceeces eeseaasseeceaenss 12 PETG ap 3 BENENNEN Yd FET ena 0 Co a nt nN Ne Nc AS RT rt SR rae Ra Ee Le EE Technical specifications Technical features HD200 sensing elements Keypad Hygrometry capacitive sensor Metal coated 5 keys Temperature Pt100 1 3 DIN 1 joystick HD200 connection Conformity On the top Electromagnetic compatibility 2 secured mini DIN connectors for SMART plus probes as per NF EN 61326 1 Left side Power supply 1 USB port for KIMO cable only 4 piles alcalines 1 5V LR6 1 power supply plug Ambient Interchangeable measurement modules Current Voltage module Connection 2 stereo jacks Thermocouple module Connection 4 inputs for compensated miniatu
5. enabled ou disabled On enabled mode the probe is connected the measurement is carried out and the value is displayed Infos Measure Params On disabled mode the probe is connected the measurement is not carried out and the value is not displayed RF probes display 2 Using wireless communication A Add a wireless probe A1 Go to probe menu by pressing Probe access key A2 With arrow keys lt and P go to RF probes display A3 Select with access key RF probes searching A4 Power up the probe and press multifunction button until LED blinks Once the probe is recognized information appears Left button lt allows to return to the wireless probes display and to access all wireless probes already recognized by the instrument With access keys it is possible to delete Del a wireless e probe RF probes detected B Select a wireless probe already created B1 Power up the wireless probe short press on Multifunction button B2 Go to Probe menu B3 With arrows keys and gt go to RF probes display All the wireless probes already recognized appear RF probes display B4 Select the suitable wireless probe with A or V B5 Go to probe informations using arrow key gt B6 Enable the wireless probe with arrows keys A and W and confirm with OK Functions The following functions are enabled only if at least one probe is connected You can access to the followi
6. er to view the temperature difference If you select Delta T again Delta T function is disabled Calculation Press the access key Calc Press gt in order to enter in the submenu and choose calculation type none psychrometer or WGBT by means of arrows keys A and V Confirm with OK Select Esc to quit this menu e Psychrometer Wet Temperature Tw is the temperature at which water evaporated into the air brings the air to saturation at the same temperature It is expressed in Celsius degree Absolute humidity pV is the ratio between the mass of water vapor present to the mass of dry gas It is expressed in grams of water vapor per kiRecrams of dry gas Dew point temperature Td is the temperature to which the air must be cooled at constant barometric pressure for water vapor to condense into water It is expressed in Celsius degree Contact dew point temperature Td is the dew point temperature measured by a PT100 contact probe It is expressed in Celsius degree Specific enthalpy i is the total heat contained in 1 kg of wet air It is expressed in kJ kg e WBGT index Wet bulb globe temperature For hygrometry probe coupled with black ball thermometer lf WBGT index is selected press W then OK or and alist appears Select Inside or Outside with arrow A and V Confirm with OK The WBGT described as per ISO 7243 allows an evaluation of working climatic conditions Outdoors the following formula i
7. ll datasets Select Delete with A and V Confirm wih OK V General information 1 Parameters e Language Click on OK or gt to enter and a list of languages available appears Select language with arrow keys A and W and Confirm wih OK e Date time Click on OK or gt to enter into sub function Enter the day with A and V then move to the next digit with B Repeat this operation for the month year hour and minute Confirm wih OK e Beep This sub function allows to enable or disable the keypad beep Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and W inorder to enable or disable the beep Confirm wih OK e Extinction This sub function allows to enable the automatic shut off and to select the delay in minute Click on OK or gt to enter into the sub function Select with A and V OFF in order to disable the automatic shut off or enter the delay from 15 to 120 minutes Confirm wih OK e RF logging This sub function allows to enable or disable the RF logging Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and W inorder to enable or disable this function Confirm wih OK e Contrast This sub function allows to modify the contast Click on OK or gt to enter Select your contrast level from 0 to 9 or AUTO with A and V Confirm wih OK e Backlit This sub function allows to modify the backlit Click on OK or
8. ng sub functions Measurement display Hold Min Max Configuration Delta T Parameters Calculation Recording Hold Min Max Alarms gt Params gt Calc Press 1x in order to select HOLD function measurement holding on display Press 2x in order to select Min Max function display of minimum and maximum values Press 3x back to the continuous measurement IV Menus Configuration lf you use thermocouple probes you must enter type into the Configuration sub function Configuration sub function allows to e Select thermocouple Click on OK or gt to enter into sub function a list of thermocouple available K J or T type appears Select type with A and V Confirm with OK e Select display Click on OK or gt to enter into sub function Select channel required with arrow keys A and W and confirm with OK Select respectively ON or OFF with A and W inorder to enable or disable this function Confirm with OK e Select units Click on OK or to enter into sub function a list of units available appears For each channel select unit required with A and V Confirm with OK Click on Esc to return to previous screen Delta T When two PT100 probes or 2 thermocouple temperature probes are connected HD200 can calculate Delta temperature value the temperature difference between C2 and C1 or T2 and T1 or T4 and T3 Select Delta T in ord
9. r KIMO cable Circular menu Elastomer protection Keypad Access keys for circular menu Browsing joystick e 4 directions e Validation Escape key On Off key Il Introduction Connections A Interchangeable measurement modules Interchangeable modules with Smart plus system are automatically recognized when connected to the instrument 1 Current Voltage module 2 Thermocouple module It allows current or voltage measurements on V A1 or It allows thermocouple temperature measurement on Tc VA 2 channels with current voltage input cables or Tc2 Tc3 and Tc4 channels with type K J or T with wire ammeter clamps thermocouple probes equiped with a miniature male connector A Wire probes with Smart plus system Wire probes with Smart plus system are automatically recognized when connected to the instrument ee Temperature and e hygrometry probes are connected on fa min DIN connectors e C1 and or C2 mini Din C2 mini Din C1 connector connector Secured Mini Din Connector Retractable cable lg 450 mm up to 2 4 m OS Wireless probe instrument communication Wireless communication between probe and instrument with automatic recognition after power up lt Sea Hygrometry probes or Pt100 probes are displayed on hygro Tr1 or Tr2 channels followed by wireless communication Wireless probes shall be located near
10. re plug of thermocouple K J ou T type Class 1 as per IEC 584 3 Neutral gas Operating and storage temperature Operating temp From 20 to 80 C Storage temp From 0 to a 50 C Auto shut off adjustable from 0 to 120 min Display l Graphic display 128x128 pixels Weight Dim 50 x 54 mm Blue blacklit Display of 6 measurements including 4 simultaneously 340g Languages Housing French English ABS shock proof IP54 Specifications Measuring units Measuring range Accuracy Resolutions CURRENT VOLTAGE ae V mA From 0 to 2 5 V 1mV 0 001 V From 0 to 10 V 10mV 0 01 V From 0 to 4 20 mA 0 01mA 0 01 mA THERMOCOUPLE See related datasheet lt T oc of K From 200 to 1 300 C 1 1 C or 0 4 Reading value 0 1 C J From 100 to 750 C 0 8 C or 0 4 Reading value 0 1 C T From 200 to 400 C 0 5 C or 0 4 Reading value 0 1 C HYGROMETRY PROBES Relative humidity RH From 3 to 98 RH Accuracy repeatability linearity 0 1 RH hysteresis STD Absolute humidity g Kg From 0 to 600 g kg 1 5 RH From 15 C to 25 C 0 1 g kg Factory calibration uncertainty 0 88 RH _ Temperature dependence 0 04 x T 20 RH if T lt 15 C or T gt 25 C Dew point Cog Ta From 50 to 80 C 0 6 of reading 0 5 C DI Ambient temperature C F From 20 to 80 C 0 3 of reading 0 25 C 0 1 C
11. s used WBGT 0 7 Thn 0 2 Tg 0 1 Ta outside Indoors It is calculated from the following formula WBGT _ 0 7 Thn 0 3 Tg inside where Thn is the natural wet temperature Tg is the temperature measured with a black ball thermometer and Ta is the ambient temperature IV Menus Alarms Select respectively ON or OFF with A and W inorder to enable or disable the alarm Choose your thresholds low temperature setpoint and high temperature setpoint Confirm with OK or gt Select thresholds with OK or to enter temperature setpoints Select or signs with A and W then pass on the first digit with B Low and high thresholds entered confirm with OK Recording The Recording menu allows a measurement dataset You can choose between a planned or a continuous dataset 1 Create or launch a continuous dataset A continuous dataset can be carried out using HD200 and is composed of several dated measuring points The operator can choose an automatic or a manual dataset with an instant value or an average This datasets can t be set using Datalogger 10 Software 1 1 Manual dataset Select dataset A manual dataset is composed of measuring points selected by the operator a Click on OK or gt to enter into sub function b Select Manual with A and V Confirm wih OK c Select Name with A and V Confirm wih OK or Enter dataset name with arrow keys lt q gt and A V Confirm wih OK
12. the instrument for initial recognition Connection between HD200 and wireless probes must be established See submenu Wireless probes p 8 lll Browsing amp ower upl Enter code Enter key code with directional pad oo oO if the locking is activated a lt gt and A v p i Homepage display Select a sub menu with access keys Infos ar Probe j gt Params Params or with arrow keys lt gt Probe connection Probes display Select a connection with right and left keys lt gt Connections can be activated or deactivated with A or V Infos Measure lt Params Select a sub menu with access keys SSK or with arrow keys lt gt Measurement Measurement display Return to previous screen Select a sub menu with access keys or with arrow keys lt gt Check probes connection IV Menus Probe menu 1 Using wire probes and modules Wire probes and modules with Smart plus system are automatically recognized from first connection The Probe menu only appears when probes or module are connected This menu allows to view probe information plugged to C2 Module C1 or wireless connections See Connections p 6 for more information about connections Probes display Available information are e Sensor type Serial number Date of last calibration or adjustement Probes Status
13. year Warranty KIMO Instruments have 1 year guarantee for any manufacturing defect return to our After Sales Service required for appraisal NTang HD 200 09 08 A We reserve the right to modify the characteristics of our product EXPORT DEPARTMENT Boulevard de Beaubourg Emerainville BP 48 d 77312 MARNE LA VALLEE CEDEX 2 AO Tel 33 1 60 06 69 25 Fax 33 1 60 06 69 29 v Ei Y V