MICROMODULE SINGLE SWITCH MAX.LOAD: 11A

image

Contents

1. off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 INSTANT POWER CONSUMPTION VARY OVER 5 REPORT When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W 2 1 3 OVERLOAD ALARM REPORT When Micromodule Single Switch Max Load 11A detects the current is more than 12A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_ Report Alarm Type 0x08 Alarm Level OxFF 2 2 RESPONSE TO METER GET COMMAND The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current 1 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 INSTANT POWER CONSUMPTION WATT OF SWITCH When receiving Meter Get Command it will report Meter Report Command to the node www Zzipato com Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report R
2. ZIPATO warrants that the products described below under normal use are free from material defects in materials and workmanship during the Limited Product Warranty Period set forth below Limited Product Warranty Period if the product is used and serviced in accordance with the user manual and other documentation provided to the purchaser at the time of purchase or as amended from time to time ZIPATO does not warrant that the products will operate uninterrupted or error free or that all deficiencies errors defects or non conformities will be corrected This warranty shall not apply to problems resulting from a unauthorized alterations or attachments b negligence abuse or misuse including failure to operate the product in accordance with specifications or interface requirements c improper handling d failure of goods or services not obtained from ZIPATO www zipato com 03 or not subject to a then effective ZIPATO warranty or maintenance agreement e improper use or storage or f fire water acts of God or other catastrophic events This warranty shall also not apply to any particular product if any ZIPATO serial number has been removed or defaced in any way ZIPATO IS NOT RESPONSIBLE FOR DAMAGE THAT OCCURS AS A RESULT OF YOUR FAILURE TO FOLLOW THE INSTRUCTIONS FOR THE ZIPATO HARDWARE PRODUCT LIMITED PRODUCT WARRANTY PERIOD The Limited Product Warranty Period starts on the date of purchase from ZIPA
3. everything under control MICROMODULE SINGLE SWITCH MAX LOAD 11A QUICK ere ae GUIDE v1 TRADEMARKS Zipato and the Zipato logo are registered Trademarks All other product names mentioned herein may be trademarks or registered trademarks of their respective companies NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual it is possible that this document may contain technical inaccuracies typographical or other errors Zipato assumes no liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose The published information in the manual is subject to change without notice Zipato reserves the right to make changes in the product design layout and driver revisions without notification to its users This version of the Installation guide supersedes all previous versions ELECTROMAGNETIC COMPATIBILITY In proper state and when operated properly the product complies with all the requirements in respect of interference radiation according to EN 301 489 17 EN 301 489 1 and EN 300 328 The connections conducting HF signals mu
4. make your home smart functions Please refer to the instructions for your Z Wave Certificated Primary Controller to access the Setup function and to include exclude associate devices Function Description LED Indication Nonede ID The Z Wave Controller does not 2 second on allocate anode ID to the Switch 2 second off Put your Z Wave controller into inclusion mode by following the instructions provided by the inclusion controller manufacturer Pressing On Off button three times within 2 seconds will enter inclusion mode Put your Z Wave controller into exclusion mode by following the instructions provided by the controller manufacturer eer Pressing On Off button three times within 2 seconds will enter exclusion mode 0 5s On 0 5s Node ID has been excluded Off Enter auto inclusion Pressing On Off button three Use this times within 2 seconds will procedure enter inclusion mode only in the event that the primary Recai Within 1 second press On Off a I5 button again for 5 seconds otherwise inoperable 05s On 053 IDs are excluded Off Enter auto inclusion Micromodule Single Switch Max Load 11A is an always listening Z Wave device so associations may be added or removed by a controller at any time OR If your controller requires to Association have the Micromodule Single Switch Max Load 11A send a node information frame or NIF for associations then pressing the On Off button three times within 2 seconds
5. FLASH MODE When the state of switch changes LED will be on only one second then LED keeps off 3 8 AUTO OFF TIMER Whenever Micromodule Single Switch Max Load 11A switches to on the auto off timer begin to count down After the timer decrease to zero it will switch to off automatically However if Auto off timer is set as 0 the auto off function will be disabled The default setting is 0 3 9 RF OFF COMMAND MODE Whenever a switch off command BASIC_SET BINARY _SWITCH_ SET SWITCH_ALL_OFF is received it could be interpreted as 4 variety of commands 3 9 1 SWITCH OFF It switches to OFF state The default setting is Switch Off 3 9 2 IGNORE The switch off command will be ignored 3 9 3 SWITCH TOGGLE It switches to the inverse of current state 3 9 4 SWITCH ON It switches to ON state 3 10 EDGE MODE PULSE MODE AND EDGE TOGGLE MODE Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode 3 10 1 EDGE MODE This mode is suitable for the bi stable wall switch that has indicator point on the switch and the same position correspond to same state of relay1 If the Micromodule Single Switch Max Load 11A relay change the state because of receiving Z Wave RF command it may need two times of change switch on to off or switch off to on to let relay back to the correspond state Manual switch S2 is disabled in this mode 3 10 2 PULSE MODE T
6. The Switch LED illuminating but cannot control the ON OFF Switch of ON OFF switch switch or follow the load attached rotontad the instruction of P protection The Switch LED 1 Not carry out 1 Carry out illuminating but association association the Detector cannot 2 Same frequency 2 Wait for a while control the Switch interference to re try Remove the load attached or check max load cannot exceed 11 0A LED keep flashing but cannot control Overload occurs MODELS AND FREQUENCIES MODELS EUROPEAN UNION EU version ph pan03 eu UNITED STATES US version ph pan03 us RUSSIA RU version ph panO3 ru ISRAEL IS version ph pan03 is AUSTRALIA AU version ph pan03 au INDIA IN version ph panO03 in FREQUENCIES EUROPEAN UNION EU 868 42 MHz UNITED STATES US 908 42MHz RUSSIA RU 869 02MHz ISRAEL IS 916 02MHz AUSTRALIA AU 921 42MHz INDIA IN 865 20MHz LIMITED PRODUCT WARRANTY GENERAL TERMS Nothing in this Limited Product Warranty affects your statutory rights as a consumer The Limited Product Warranty set forth below is given by Tri plus grupa d o o Europe herein referred to as ZIPATO This Limited Product Warranty is only effective upon presentation of the proof of purchase Upon further request by ZIPATO this warranty card has to be presented too make your home smart EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY ZIPATO MAKES NO OTHER WARRANTIE
7. Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF make your home smart Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF 1 2 BASIC_SET SWITCH_BINARY_SET Upon receipt of the following commands from a Z Wave the load attached to the Switch will turn on or off Command Class Basic Basic Set Value 1 99 255 OxFF the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 the load attached to the Switch turns off 2 Z WAVE S GROUPS ASSOCIATION COMMAND CLASS VERSION 2 The Switch can be set to send associated Z Wave devices It supports one association group with one node support for Grouping 1 For group 1 the Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_ REPORT ALARM_REPORT 2 1 AUTO REPORT TO GROUPING 1 MAXIMUM NODE 1 2 1 1 ON OFF EVENT REPORT When on or
8. C RANGE Minimum 30m in door 70m outdoor line of sight WEIGHT 39g DIMENSIONS 47mm x 39mm x 15 60mm Z WAVE SUPPORTED COMMAND CLASS COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_SECURITY COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_METER_V3 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ALARM COMMAND_CLASS_PROTECTION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 ADDING TO Z WAVE NETWORK In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion AUTO INCLUSION The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet Note Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seconds Unlike inclusion function as shown in the table below the execution of auto inclusion is free from pressing the On Off button on the Switch The table below lists an operation summary of basic Z Wave
9. GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS This Limited Product Warranty applies to ZIPATO branded hardware products collectively referred to as ZIPATO Hardware Products sold by ZIPATO Europe its European subsidiaries affiliates authorized resellers or country distributors collectively referred to as ZIPATO Resellers with this Limited Product Warranty The term ZIPATO Hardware Product is limited to the hardware components and all its internal components including firmware The term ZIPATO Hardware Product DOES NOT include any software applications or programs GEOGRAPHICAL SCOPE OF THE LIMITED PRODUCT WARRANTY This Limited Product Warranty is applicable to Hardware Products sold by Zipato Resellers in all countries listed at the beginning of this document under the heading Countries in which this ZIPATO Limited Product Warranty applies The Limited Product Warranty will be honored in any country where ZIPATO or its authorized service providers offer warranty service subject to the terms and conditions set forth in this Limited Product Warranty However warranty service availability and response times may vary from country to country and may also be subject to registration requirements LIMITATION OF PRODUCT WARRANTY
10. Meter Value V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC LOAD CURRENT 1 When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Valuell make your home smart Example Scale 0x05 I Precision 2 Size 2 2 Bytes of Meter Value 1 0x01 1 Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 LOAD POWER FACTOR PF When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave s Configuration Configuration Parameter 1 Watt Meter 2 0x01 Report Period 0x7FFF 720 5s 3600s 1 5s 720 hour KWH Meter Report Period Threshold of current for Load 2 10 1100 cauti
11. S EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES IN THIS WARRANTY STATEMENT ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AGAINST ZIPATO THEY DO NOT HOWEVER AFFECT OR RESTRICT THE RIGHTS YOU HAVE AGAINST THE BUSINESS YOU BOUGHT A ZIPATO PRODUCT FROM IN NO EVENT WILL ZIPATO BE LIABLE FOR LOSS OF DATA OR FOR INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL INCLUDING LOST PROFIT OR DATA OR OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE HOWEVER NOTHING IN THIS AGREEMENT LIMITS ZIPATO S LIABILITY TO YOU I IN THE EVENT OF DEATH OR PERSONAL INJURY TO THE EXTENT RESULTING FROM ZIPATO S NEGLIGENCE OR II TO THE EXTENT RESULTING FROM ANY FRAUDULENT MISREPRESENTATION ON THE PART OF ZIPATO OR III TO THE EXTENT ARISING UNDER PART 1 OF THE CONSUMER PROTECTION ACT 1987 OF THE UNITED KINGDOM SOME STATES OR COUNTRIES DO NOT ALLOW 1 A DISCLAIMER OF IMPLIED WARRANTIES 2 A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR 3 LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS IN SUCH STATES OR COUNTRIES SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY TO YOU THIS LIMITED WARRANTY
12. TO Your dated sales or delivery receipt showing the date of purchase of the product is your proof of the purchase date You may be required to provide proof of purchase as a condition of receiving warranty service You are entitled to warranty service according to the terms and conditions of this document if a repair to your ZIPATO branded hardware is required within the Limited Product Warranty Period Other than in respect of products for domestic use in particular those listed in the first and last boxes in the table below this Limited Product Warranty extends only to the original end user purchaser of this ZIPATO Hardware Product and is not transferable to anyone who obtains ownership of the ZIPATO Hardware Product from the original end user purchaser PRODUCT WARRANTY PERIOD TABLE Micromodule Single Switch PRODUCT TYPE Max Load 11A One 1 year PRODUCT WARRANTY PERIOD IMPORTANT The content of Product Type listed above is subject to change please refer to the www zipato com for latest update PERFORMANCE OF THE LIMITED PRODUCT WARRANTY If a product defect occurs ZIPATO s sole obligation shall be to repair or replace any defective Zipato Hardware Product free of charge provided it is returned to an Authorized ZIPATO Service Centre during the Limited Warranty Period Such repair or replacement will be rendered by ZIPATO at an Authorized ZIPATO Service Centre All component parts or hardware products t
13. ate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 OxEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 2 2 2 ACCUMULATED POWER CONSUMPTION KW H When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x00 Size 4 Meter Value KWh Example Scale 0x00 KWh Precision 2 Size 4 Bytes KW h Meter Value 1 0x00 KWh Meter Value 2 0x01 KWh Meter Value 3 0x38 KWh Meter Value 4 0xA3 KWh Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h 2 2 3 CLEARING ACCUMULATED POWER CONSUMPTION Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC LOAD VOLTAGE V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 Size 2
14. d builds its products to be as environmentally friendly as possible by using recyclable low toxic materials in both products and packaging CONTACT SUPPORT E MAIL support azipato com Mon Fri 9 00am 05 00pm CET www zipato com COPYRIGHT 2014 Tri plus grupa d o o All Rights Reserved No part of this manual may be reproduced or transmitted in any form without the expressed written permission of Tr make your home smart www zipato com 05
15. ence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DISPOSING AND RECYCLING YOUR PRODUCT H eij This symbol on the product or packaging means that according to local laws and regulations needs to be disposed of separately from household waste and sent to recycling because it contains electronic components and a battery Once this product has reached the end of its life please take it to a collection point recycle facilites designated by your local authorities some will accept your product for free or simply drop it off at your Zipato re seller store By recycling the product and its packaging in this manner you help to conserve the environment and protect www zipato com human health At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs an
16. hat are replaced under this Limited Product Warranty become the property of ZIPATO The replacement part or product takes on the remaining Limited Warranty Period of the replaced part or product The replacement product need not be new or of an identical make model or part ZIPATO may in its discretion replace the defective product or any part thereof with any reconditioned equivalent or superior product in all material respects to the defective product WARRANTOR Tri plus grupa d o o Banjavciceva 11 10 000 Zagreb CROATIA TEL 385 0 1 4004 404 FAX 385 0 1 4004 405 DECLARATION OF CONFORMITY The Manufacturer Tri plus grupa d o o hereby declares that the product Micromodule Single Switch Max Load 11A q make your home smart In accordance with the following Directive s 2006 95 EC The Low Voltage Directive 89 336 EEC The Electromagnetic Compatibility Directive and 1999 5 EC R amp TT EC Directive is in conformity with the e applicable requirements of the following documents EN 61326 EN 61000 3 3 EN 61000 4 4 EN 61000 4 11 IEC EN 55011 EN 61000 6 2 EN 61000 4 5 EN 301 489 1 3 EN 300 220 2 EN 61000 4 2 EN 61000 4 6 AS NZS IEC 60335 2 97 EN 61000 3 2 EN 61000 4 3 EN 61000 4 8 EN 60335 1 hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications The unit complies with all applicable Essential Requirements of the Directives Perso
17. his mode is suitable for the toggle type wall switch to swap the state of Relay1 3 10 3 EDGE TOGGLE MODE This mode is suitable for the normal bi stable switch whenever change the state of the wall switch will also swap the state of Relay1 4 PROTECTION COMMAND CLASSES Micromodule Single Switch Max Load 11A supports Protection Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state www Zzipato com After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected OVER THE AIR FIRMWARE UPDATE Micromodule Single Switch Max Load 11A is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF media It is a helpful and convenient way to improve some function If needed TROUBLESHOOTING 1 Check power The Switch is not connections The Switch not plugged into the 2 Don t open up the working and LED off electrical outlet Switch and send it properly for repair 1 Set the ON OFF switch of the load attached to ON 2 Unprotected the 1 Check if the load plugged into the Switch has its own
18. is 1100 when the load current of Relay1 over this value Micromodule Single Switch Max Load 11A will send current meter report to warn the Group1 node the Range of the setting value is from 10 to 1100 and the default value is 1100 3 4 THRESHOLD OF KWH FOR LOAD CAUTION This is a warning when the KWh of load over the preset threshold value if the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value Micromodule Single Switch Max Load 11A will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 5 RESTORE SWITCH STATE MODE Whenever the AC power return from lost Micromodule Single Switch Max Load 11A will restore the switch state which could be make your home smart SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 MANUAL ON OFF MODE The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On but not Off This is useful function for keeping the device in switch on state 3 7 LED INDICATION MODE 3 7 1 SHOW SWITCH STATE When switch is on LED is on When switch is off LED is off The default setting is Show Switch State 3 7 2 SHOW NIGHT MODE When switch is on LED is off When switch is off LED is on 3 7 3 ONE
19. lowe foe NEUTRAL LIVE INCLUDE_BUTTON APPLICATION IN WALL SWITCH 1 RELAY 1A TYPE L Switch www zipato com INTRODUCTION Micromodule Single Switch Max Load 11A is a security enabled wireless switch based on Z Wave Plus technology Z Wave Plus enabled devices displaying the Z Wave Plus logo can also be used with it regardless of the manufacturer and can also be used in other manufacturer s Z Wave enabled networks Remote On Off control of the connected load is possible with other manufacturer s wireless Controller Each switch is designed to act as a repeater Repeaters will re transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots Because Micromodule Single Switch Max Load 11A supports Security Command Class it can learn with Secured controller Its functionality and supported command classes is identical when included as a secure and non secure device Micromodule Single Switch Max Load 11A is able to detect instance wattage and overload current 12A of connected lights or appliances When detecting overload state the Switch will be disabled and its On Off button will be lockout of which LED will flash quickly However unplug and re connect the switch will reset its overload condition to normal status SPECIFICATION OPERATING VOLTAGE 230V 50HZ MAXIMUM LOAD 11A OPERATING TEMPERATURE 0 C 40
20. n responsible for this declaration Dean Janacek Certification Manager 01 09 2012 Changes or modifications not expressly approved Tri plus grupa d o o for compliance could void the user s authority to operate the equipment Ke THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lec trique subi m me si le brouillage est susceptible d en comprom ettre le fonctionnement NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer
21. on 0 01A 1100 1100 0 01A 11A Threshold of KWh for Load 2 1 10000 caution Restore switch state mode 1 0 2 0 Switch off 1 1 Last switch state 2 Switch on www zipato com 02 Configuration Parameter 6 Manual On Off mode 0 Disable manual On Off 1 Enable manual On Off Configuration Parameter 7 LED indication mode 1 1 3 1 Show switch state 1 2 Show night mode 3 One flash mode Configuration Parameter 8 Auto off timer 2 0 0x7FFF 0 Disable auto off function le a 1 0x7FFF 1s 32767s RF off command mode 1 0 3 0 Switch off 0 1 Ignore 2 Switch toggle 3 Switch on 3 1 WATT METER REPORT PERIOD If the setting is configured for 1hour set value 720 the Micromodule Single Switch Max Load 11A will report its instant power consumption every 1 hour to Group1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr 3 2 KWH METER REPORT PERIOD If the setting is configured for 1hour set value 6 the Micromodule Single Switch Max Load 11A will report its Accumulated Power Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 THRESHOLD OF CURRENT FOR LOAD CAUTION This is a warning when the current of load over the preset threshold value if the setting value
22. st neither be manipulated nor damaged TAKE CARE OF YOUR SAFETY Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required DANGER RISK OF ELECTROCUTION All work on the device should only be carried out by trained and skilled electricians Observe the country specific regulations CAUTION The connected devices and the flush mounted receiver can become damaged if devices are operated that do not correspond to the technical specifications see technical data DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT The device has no basic insulation and must therefore be installed in a way that protects against accidental contact DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT When installing a wall plate the distance between the cover s fixing brackets or screws and the connections of the flush mounted Micromodule Single Swtich Max Load 11A must be at least 4 mm once installed If the distance is less than 4 mm a deeper installation box must be used The fixing brackets or screws of the cover must not press against the housing Only insulated tools may be used for operation on the device e g an insulated phase tester make your home smart D IGURE 1 imensions unit mm
23. tate occurs the Switch is disabled of which LED flashes on and off Overload alternately at 0 5 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet CHOOSING A SUITABLE LOCATION Do not locate the Switch facing direct sunlight humid or dusty place The suitable ambient temperature for the Switch is 0 C 40 C Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal INSTALLATION AND OPERATION Put the in wall switch into a wall box and connect the AC power wire L N to Micromodule Single Switch Max Load 11A s Land N Connect the wall switch to the Micromodule Single Switch Max Load 11A as shown in picture There are 3 modes Micromodule Single Switch Max Load 11A can be configured to match different kind of wall switch please refer to 3 10 Edge Pulse Edge Toggle modes which are described in next section of this user manual PROGRAMMING 1 BASIC COMMAND CLASS BINARY SWITCH COMMAND CLASS The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller the Switch will report its On Off state to the node asked BASIC GET COMMAND COMMAND CLASS BASIC BASIC GET
24. will cause the Micromodule Single Switch Max Load 11A to send its NIF There is only one group for the switch Note Including a node ID allocated by Z Wave Controller means inclusion Excluding a node ID allocated by Z Wave Controller means exclusion Note Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes people are not easy to execute exclusion or inclusion especially when Micromodule Single Switch Max Load 11A already installed in a wall box To solve this issue Micromodule Single Switch Max Load 11A support a special feature that can use S1 or S2 to execute exclusion inclusion Reset or Association at the first 3 minutes when first time connect to main power LED INDICATION To know what mode the switch is in view from the LED identification State Type LED Indication Whenever we switch On and Off of the Micromodule Single Switch Max Load 11A by S1 S2 or On Off button or RF command the LED will lights up 1 second and then off Normal www zipato com 01 Under normal operation when the Switch has not been allocated to a node ID the LED flashes No node ID on and off alternately at 2 second intervals By pressing S1 S2 or On Off button it will stop flashing temporarily When Micromodule Single Switch Max Load 11A is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Learning When overload s