1. Panel Meters Series M Panel meters 96x48mm Model M40 T Pt100 RTD Dom Thermocouples Panel meter for Pt100 RTD 2 and 3 wires and thermocouples J K T E S R N C y L and X with temperature display in degrees celsius C or fahrenheit F Selectable Pt100 RTD resolution at 1 or 0 1 and manual offset available Thermocouple measure with internal CJC selectable enabled or disabled Selectable behavior in case of sensor break to_high or to_low Size 96x48mm Reading with 4 digits Maximum and minimum display memory steps alarms with single or double setpoints 5 levels of brightness Universal AC and DC power modules and up to 3 modules for signal retransmission and control relay outputs analogue outputs FEMA ELECTRONICA USER S MANUAL 2185R04 User s Manual M40 T 1 Meter M40 T Panel meter 96x48mm size for Pt100 RTD and thermocouples Panel meter for temperature signals accepts Pt100 RTD with 2 and 3 wires and thermocouples J K T E S R N C Land X Temperature display in degrees celsius C or fahrenheit F Thermocouple cold junction compensation selectable Manual offset selectable Selectable behavior for alarms in case of sensor break to_high or to_low Instrument with 96x48mm standard DIN size Resolution 4 digits plus negative sign Management for up to 3 alarms with 1 or 2 setpoints each a
2. 11 1 7 Technicaldata 2 04 4 1 17 CE declaration of conformity 11 1 7 Technical data cont ee eee 4 2 Output and control modules 12 1 8 Mechanical dimensions mm 5 21ModuleR1 0 504 12 1 9 Operating the menus 6 2 2 Module AO 4 ote kaon See oe ee ws 12 1 10 Configuration menu 6 2 3 Modules R2 R4 R6 13 TIN SO OU ARONA SAU CON raro eae a i 3 More options and accessories 14 1 10 1 Input MENU LL 8 7 1 Option NBT 14 1 10 2 Temperature configuration 8 79 Option sia eli ad Sk tee cs eed 14 Ca eae o a boda ips 14 E n PSS ENG e di eA See at g 7 4BenchtophousingTHM 14 1 10 6 Menu OptX Options 2 9 CADIS ED itis Mit erage Sag pu Lai FEMA ELECTRONICA Page 2 User s Manual M40 T 1 2 Front View 1 5 Signal connections Pt100 RTD Alarms A CG ND an HE ac a cee SJ ay I Logo a 4 4 m Cj Button LE m UP Button SQ Access to Access to Information Menu Configuration Menu 1 3 Rear View Option3 Option1 Option2 S
3. AL PA Alpha FEMA ELECTRONICA Page 6 Offset counts to add Reading to high Reading to low User s Manual M40 T 1 10 Configuration menu cont I Al c Eool PRS5 on 8888 Tools Password E E Select password AL jo Ack Dn Al active o Alarm1 Active 3 E E Anecie Ss FAcE no Factory Ly P E gt I A H Alarm as max a a E I ae Alarm type f mn Alarm as min DO I U E cr H H H H Firmware version Version SEL gt 444 Setpoint LI bh LI Ly Minimum hY5E BAA cons son LIDO Hysteresis L i LG J Standard GEL gt BGA seconds Fr poy LI G4 y II I i GEE on H8858 LI LS Mem Setpoint2 S d setpoint ee F F econd setpoin ES O o P L Menu for optional module at Opt1 i _ Option1 Al L C c Menu for Alarm2 a P L cl Menu for optional module at Opt2 AL r J Menu for Alarm3 Option2 V ea Tn P E J Menu for optional module at Opt3 Option3 y d ISPIHSEEPI on 4 Display Steps ta m O cul 50 OFF Se Counts for s
4. 1 8 Mechanical dimensions mm Panel cut out 92 FEMA ELECTRONICA Page 5 User s Manual M40 T 1 9 Operating the menus 1 10 Configuration menu The instrument has two menus accessible to the user Configuration Menu key SQ Information Menu key UP The Configuration Menu allows to change the configuration of the instrument Access to the Configuration Menu can be password protected with the function PASSWORD During operation with the Configuration Menu the alarms are kept on hold When leaving the Configuration Menu the instru ment performs a restart and new configuration is applied On restart of the instrument also the control output modules are restarted relays analogue outputs The Information Menu is for information only and it does not accept changes on the displayed information To enter the In formation Menu press the UP button It is not affected by the PASSWORD function Leaving the Information Menu returns to the measuring state of the instrument without restart of the unit Rollback After 30 seconds without interaction from the operator the instrument leaves the menu and returns to the previous working mode In case of configuration menu all changes are discarded Button SQ Selects
5. 385 or 390 ac cording to your Pt100 RTD sensor 1 10 3 Alarms The instrument can manage up to 3 alarms These alarms control optional relays R1 see section 2 1 which can be installed at slots Opt1 Opt2 and Opt3 More alarms can be achieved by installing special control modules R2 R4 and R6 Configuration menus for special modules are not listed in this document Active ACT Value ON OFF Defines if the instrument has to manage this alarm or not Select OFF for alarm not managed Type TYPE Value MAX MIN Defines the behavior of the alarm as maximum or minimum alarm The alarms con figured as maximum are activated when the display value is equal or higher than the setpoint The alarms configured as maximum are deactivated when the display is lower than the setpoint The alarms configured as minimum have the inverse behavior Setpoint SET Value from 9999 to 1999 Alarm set point User s Manual M40 T Hysteresis HYSt Value from 0 to 9999 Points of hyster esis The hysteresis applies on the deactivation of the alarm Delay DEL Value from 0 0 to 99 9 seconds Delay to be applied to the relay activation and deactivation Relays are activated and deactivated X seconds after the activation deactivation of the alarm The delay affects only to the relays The delay does not affect to the front leds Setpoint2 SET2 Value from
6. Risk of electric shock Removing the front cover will grant access to the internal circuits Disconnect the input signal to prevent electric shock to the operator Operation must be performed by qualified personnel only Without push buttons 7 2 Option G Green led option Green led 7 3 Option IP65 This option provides M series panel meters with IP65 front protection The instrument is provided with the front cover sealed NOTE Removing the front cover to access the inside of the instrument will permanently disable the IP65 protection see section 1 14 7 4 Benchtop housing THM Benchtop housing for M series of panel meters Handle with three selectable positions and power connector with manual switch and fuse holder 7 5 Adapter DRA M Adapter for DIN rail mount FEMA ELECTRONICA Page 14 User s Manual M40 T FEMA ELECTRONICA Page 15 other products Panel Meters Panel Meters Panel Meters Standard 96x48mm Small 72x36mm Miniature 48x24mm b lt Large Displays Signal Converters Bar Meters 60 amp 100mm digit amp Isolators www fema es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRONICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 600
7. 61000 4 2 By contact 4KV Criteria B On air 8KV Criteria B 61000 4 3 Criteria A 61000 4 4 On AC power lines 2KV Criteria B On DC power lines 2KV Criteria B On signal lines 1KV Criteria B 61000 4 5 Between AC power lines 1KV Criteria B Between DC power lines 0 5KV Criteria B 61000 4 6 Criteria A 61000 4 8 30A m at 50Hz Criteria A 61000 4 11 0 1 cycle Criteria A 40 10 cycle Criteria B 70 25 cycle Criteria B 0 250 cycle Criteria B Barbera del Valles November 2011 Daniel Junca Quality Manager FEMA ELECTRONICA Page 11 User s Manual M40 T 2 Output and control modules 2 1 Module R1 Module with 1 relay Up to a maximum of three R1 modules can be installed in one M Series panel meter For more re lay output needs check special modules R2 R4 and R6 For more information see document 2654 M SERIES OP TIONAL_MODULES at www fema es Relay type 3 contacts Common NC NO Maximum current 8A resistive load Voltage 250 Vac continuously Installable at Option1 and or Option2 and or Option3 Opt 1 Opt 2 ABC ABC PR Em O Terminal A Common Terminal B NO Normally Open Terminal C NC Normally Closed 2 2 Module AO Module with 1 analogue output Configurable 4 20mA or 0 10Vdc Output signal proportional to the reading Scal ing through the frontal keypa
8. 1999 to 9999 Second setpoint The second setpoint allows for the creation of acti vation windows If the alarm is configured as maximum with setpoint 1000 and setpoint2 is configured at 1500 the alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is lt 1000 and gt 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays 1 10 4 Display Functions on this menu allow for configuration of the visu alization Steps STEP Display changes on predefined steps Values are 1 2 5 10 20 and 50 The display is made in steps of X counts For example select a step of 20 will make the display to change in steps of 20 1420 1440 1460 Maximum MAX Memory of maximum display Indicates the maximum value of display since the last reset of the memory Memory is reset on the following cases manual reset from the Configuration Menu Maximum change on the input signal Input modification on the scaling Scaling change on the decimal point dP modification of the linear ization segments or instrument power down Minimum MIN Memory of minimum display Indicates the minimum value of display since the last reset of the memory Memory is reset on the following cases manual reset from the Configuration Menu minimum change on the input signal Input modification on the scaling Scaling change on the decimal point dP modification of
9. Deep from panel Protection 85 to 265 Vac dc 11 to 60 Vdc and 24 48Vac lt 4W 3500Veff for power H 2000Veff for power L all levels tested for 60 seconds 3 frontal push buttons yes configurable yes yes yes configurable yes yes 5 levels 3 free slots panel plug in screw terminals lt 150 grams ABS polycarbonate 96x48mm 92x44mm 91mm including terminal IP54 standard IP65 optional Front sealed Open ing the front breaks the seal Temperature Operation 0 to 50 C Temperature Storage Warm up 20 to 70 C 15 minutes g Span drift 328 F 0 05 C 0 10 C Thermocouple J 1200 200 C 328 F 0 05 C 0 20 C Thermocouple K 1372 200 C 328 F 0 05 C 0 20 C Thermocouple T 400 200 C 328 F 0 02 C 0 02 C Thermocouple E 1000 200 C 328 F 0 05 C 0 20 C Thermocouple S 1768 50 C 58 F 0 20 C 0 20 C Thermocouple R 1600 50 C 58 0 20 C 0 20 C 1300 200 C 2320 Thermocouple N Thermocouple C Thermocouple L Thermocouple X 328 F 0 05 C 0 20 C 0 e 4192 32 F 0 02 C 0 02 PC 900 200 C 1652 328 F 0 05 C 0 20 PC 4000 200 C 7232 328 F 0 029 C 0 02 C Table 3 Thermocouple and PT100 RTD specifications FEMA ELECTRONICA Page 4 User s Manual M40 T
10. 3 info fema es
11. clean by using a humid rag and do NOT use abrasive products such as alcohols solvents etc General recommendations for electrical installations apply and for proper functionality we recommend if possible install the instrument far from electrical noise or magnetic field generators such as power relays electri cal motors speed variators If possible do not install along the same conduits power cables power motor controllers electrovalves together with signal and or control cables Before proceeding to the power connection verify that the voltage level available matches the power levels indicated in the label on the instrument In case of fire disconnect the instrument from the power line fire alarm according to local rules disconnect the air conditioning attack fire with carbonic snow never with water FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barbera del Vall s BARCELONA SPAIN www fema es info fema es Manufacturer Products M40 T The manufacturer declares that the instruments indicated comply with the directives and rules indicated below Directive of electromagnetic compatibility 2004 108 CEE Directive of low voltage 73 23 CEE Security rules 61010 1 Equipment Fixed Permanently connected Pollution Degree 1 and 2 without condensation Isolation Double Emission rules 61000 6 4 Generic rules of emission Immunity rules 61000 6 2 Generic rules of immunity
12. d Up to a maximum of three AO modules can be installed in one M Series panel meter For more information see document 2654 M SERIES OP TIONAL MODULES at www fema es Output 4 20mA 0 10Vdc selectable Accuracy 0 1 FS Isolated yes 1000Vdc Thermal drift 50 ppm C for Vdc 60 ppm C for mA Installable at Option1 and or Option2 and or Option3 Opt 1 Opt 2 MV ABC MV ABC E EE EE o a a lt si O gt Ibo Jumper M mode mA Jumper V mode Vdc Terminal A Vexc 13 8Vdc 25mA Terminal B Signal output mA or Vdc Terminal C GND FEMA ELECTRONICA Page 12 User s Manual M40 T 2 3 Modules R2 R4 R6 Special modules with 2 4 and 6 relays Use special modules R2 R4 or R6 when standard R1 modules do not provide required functionality for your application Only one special module R2 R4 or R6 can be installed in an M Series panel meter Special modules R2 R4 and R6 are not compatible with R1 modules Configuration is done through the OPTx entry of the con figuration menu Functionality for R2 R4 and R6 modules differs from standard R1 modules For more information see document 2654_M SERIES_OPTIONAL_MODULES at www fema es Number of relays 2 40r6 Relay type 3 contacts Common NO NC Maximum current 6A resistive load each relay Voltage 250 Vac continuously Ins
13. f maximum Memory of minimum HL r i HHHH On Off Alarm1 Aire AL rd HAHH Max Min affi Setpoint HASSE Hysteresis HEA ii Y JEL Delay GOGH Seconds SE EE Second af ff Setpoint2 setpoint See menu for Alarm1 See menu for Alarm1 afk HHHH Option installed Option1 oFf d _HHHH Option installed Option2 y DP E 3 HHHH Option installed Option3 Configuration Conf Information on the configured input sensor and the degrees selected Maximum MAX Value of the maximum display Minimum Min Value of the minimum display AlarmX ALX Configuration of alarm X The sequence of information shows if the alarm is being managed On Off the alarm type Max Min the setpoint the hysteresis value the activation delay and the value of setpoint2 Off or the setpoint2 value OptionX OptX Type of module installed If there is no module shows nonE 1 14 Accessing the instrument You may need to access the inside of the instrument to insert additional modules Use a flat screwdriver to unlock the upper clips marked with A Then unlock the lower clips marked with B and move out the front filter Let the inside of the instrument slide out
14. he manufacturer eligible for responsibility on additional damages or costs 1 16 Installation precautions Risk of electrical shock Instrument terminals can be connected to dangerous voltage Instrument is in conformity with CE rules and regulations See CE Declaration of Conformity further in this document Instrument protected with double isolation No earth connection required This instrument has been designed and verified according to the 61010 1 CE security regulation and is designed for applications on industrial environ ments See the CE Declaration of Conformity further in this document for information on the category of measure and the degree of pollution levels that apply Installation of this instrument must be performed by qualified personnel only This manual contains the appropriate information for the installation Using the instrument in ways not specified by the manufacturer may lead to a reduction on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action The instrument does not have a general switch and will start operation as soon as power is connected The instrument does not have protection fuse the fuse must be added during installation The instrument is designed to be panel mounted An appropriate ventilation of the instrument must be assured Do not expose the instrument to excess of humidity Maintain
15. ignal Power 1 4 Power Connections 890 Earth connection Although a terminal is offered for earth connection the connection is optional The instrument does not need this connection for correct functioning nor for compliance with the security regulations Fuse To comply with security regulation 61010 1 add to the power line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag Measure can be selected for 2 or 3 wire systems 12 3 Select input Pt100 2Wires in the menu Terminal 2 can be left un connected RTD Pt100 2 wires 123 ae Select input Pt100 3Wires in the menu RTD Pt100 __ 3 wires 1 6 Signal connections Thermocouples To configure select the appropriate thermocouple type in the configuration menu 12 3 gt FEMA ELECTR NICA Page 3 User s Manual M40 T 1 7 Technical data 1 7 Technical data cont Digits 4 Type 7 segments red Height 14mm Display maximum 9999 Dis
16. larm with hysteresis and delays Provides memory for maxi mum and minimum display on selectable steps password and selectable levels of brightness Power options with universal AC and DC ranges and space for 3 additional control and or signal retransmission modules Standard IP54 front protection with optional upgrade to IP65 protection Optional with green led Connections via plug in screw terminals and configuration via three front push buttons For application on industrial environments 1 1 Order reference Model Power Option1 Option2 Option3 Others M40 T H H 85 265 Vac dc R1 1 relay R1 1 relay R1 1 relay 65 IP65 L 11 60 Vdc AO Analogue output AO Analogue output AO Analogue output G green led and 24 48 Vac empty empty empty empty Index 1 Meter M40 T clcc 000 2 1 11 Default factory configuration 9 1 1 Orderreference 2 1 12 Messages and errors 9 1 2 Front View a ana ba int 3 1 13 Informationmenu 10 1 3RearView 0 20 0 0 0002 eee ee 3 1 13 1 Information menu 10 1 4 Power Connections 3 1 14 Accessing the instrument 10 1 5 Signal connections Pt100 RTD 3 1 15 Warranty a e e a Bre eho eo a 11 1 6 Signal connections Thermocouples 3 1 16 Installation precautions
17. of the housing To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules cor rectly fit into the internal guiding slides of the housing Once introduced place again the front filter by clipping first the upper clips A and then the lower clips B Important If your instrument was delivered with the IP65 front seal option accessing the inside of the instrument will perma nently break the IP65 seal on the areas of clips A and B Risk of electric shock Removing the front cover will grant access to the internal circuits Disconnect the input signal to prevent electric shock to the operator Operation must be performed by qualified personnel only FEMA ELECTRONICA Page 10 User s Manual M40 T 1 15 Warranty 1 17 CE declaration of conformity All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident or manipulation by non authorized personnel In case of mal function get in contact with your local provider to arrange for repair Within the warranty period and after examination by the manufacturer the unit will be repaired or substituted when found to be defective The scope of this warranty is limited to the repair cost of the instrument not being t
18. play minimum 9999 Decimal point selectable 8 8 8 8 Overrange 9999 flashing Underrange 9999 flashing Signals accepted Temperature scale Display units Pt100 RTD and Thermocouples ITS90 C or F selectable Thermocouple data Thermocouples acceptedJ K T E S R N C L X Thermocouple X is a linear 10uV C signal Resolution 1 Ranges see table 3 Max error at 25 C see table 3 Offset drift see table 3 Span drift see table 3 Note span drift includes also the offset drift CJC automatic On Off selectable CJC accuracy lt 1 0 C CJC thermal drift lt 0 04 9 C On sensor break to high or to low selectable Acquisitions 3 acquisitions second Pt100 RTD data Sensors accepted 2 or 3 wire selectable Resolution 1 or 0 1 selectable Ranges see table 3 Alpha Alpha385 or Alpha390 selectable Max error at 25 C see table 3 Offset drift see table 3 Span drift see table 3 Note span drift includes also the offset drift Cable compensation up to 14 Ohm Compensation accuracy lt 0 02 C Ohm Acquisitions 4 acquisitions second Pt100 RTD 800 200 C Max error at 25 C Power Power H Power L Consumption Isolation Configuration Functions available Steps Memory of maximum Memory of minimum Password Double setpoints Brightness control Optional boards Mechanical Mounting Connections Weight Housing materials Front size Panel cut out
19. tallable at slot Opt 1 R2 fills OPT1 R4 fills OPT1 and OPT2 R6 fills OPT1 and OPT2 and OPT3 Terminal Plug in screw terminals pitch 3 81mm Terminals approved for 300V according to UL1059 groups B and D and 160V according to VDE in CAT III and pollution degree 3 FEMA ELECTRONICA Page 13 R4 Opt 1 Opt 2 ABCDEF GHIJKL Reu SS re Z T R6 Terminal A Relay1 Common Terminal B Relay1 NO Normally Open Terminal C Relay1 NC Normally Closed Terminal D Relay2 Common Terminal E Relay2 NO Normally Open Terminal F Relay2 NC Normally Closed Terminal G Relay3 Com n Terminal H Relay3 NO Normally Open Terminal Relay3 NC Normally Closed Terminal J Relay4 Common Terminal K Relay4 NO Normally Open Terminal L Relay4 NC Normally Closed Terminal M Relay5 Common Terminal N Relay5 NO Normally Open Terminal O Relay5 NC Normally Closed Terminal P Relay6 Common Terminal Q Relay6 NO Normally Open Terminal R Relay6 NC Normally Closed User s Manual M40 T 3 More options and accessories 7 1 Option NBT Panel meter without frontal key pad To configure the instru ment uninstall from the panel and remove the front cover Once the front cover is removed internal push buttons are accessible Optionally order the instrument configured from factory
20. tep MAH gt BABA vate Memory of maximum IT E L L Reset Ulm AAAA veue Memory of s minimum C E L Reset FEMA ELECTRONICA Page 7 1 10 1 Input menu The input menu selects the input signal range Options avail able are Pt100 RTD 2 or 3 wires and thermocouples J K T E S R N C Land X Note Thermocouple X is a linear signal at 10uV C 1 10 2 Temperature configuration The temperature configuration menu sets the function param eters for Pt100 RTD and thermocouple sensors Degrees DEG Value C F Select the temperature to be displayed in celsius or fahrenheit degrees Pt100 RTD resolution P RES Value 1 0 1 Resolution for the Pt100 RTD Select to display with degree or tenth of degree resolution Offset OFFS Value from 9999 to 9999 counts Offset to be added to the reading Both for Pt100 RTD and ther mocouples Thermocouple Cold Junction Compensation T CJC Value On Off Select On for automatic CJC compensation in the instrument Select Off to disable the CJC compensa tion On break ON BK Value to h to Select To L to make the reading go to minimum in case of probe broken Select To H to make the reading go to maximum in case of probe broken Alpha ALPH Value 385 390 Select
21. the linearization segments or instrument power down 1 10 5 Tools Password PASS Selecta number to act as password This password will be requested when entering the Configuration Menu To deactivate the password select Off Factory Settings FACT Factory default configuration Select YES to activate the factory default configuration Version VER Firmware version installed Light LIGH Luminosity Select between 5 predefined levels of luminosity FEMA ELECTRONICA Page 8 User s Manual M40 T 1 10 6 Menu OpiX Options 1 11 Default factory configuration Menu options OPT1 OPT2 and OPT3 give access to the configuration menus of the options installed at slots Opt1 Opt2 and Opt3 This menu depends on the installed option If there is no option installed the instrument shows NONE Control modules R1 are controlled from the standard alarm menu see section 1 12 7 Sensor Pt100 2Wire Degrees C Resolution 0 1 Offset 0 On Break To high Alpha 385 Alarms 1 2 and 3 Active Off not managed Type maximum Setpoint 1000 Hysteresis 0 counts Delay 0 0 seconds Setpoint2 Off Display Steps Off Memory of maximum 9999 Memory of minimum 9999 Tools Password Off Brightness 3 1 12 Messages and errors When the instrument detects that the displayed value does not correspond to the input value the display will flash and alternate with a message h
22. the menu entry currently displayed When entering a numeric value for example a setpoint value validates the value on display Button UP Moves vertically on the menu entries When entering a numeric value for example a setpoint value modifies the current digit by increasing its value up from 0 to 1 2 3 4 5 6 7 8 9 Button LE Leaves the current menu Pressing LE several times will leave all menus When leaving all menus in the configuration menu changes will be saved When entering a numeric value for example a setpoint value it moves from one digit to the next Each digit value can then be modified with the UP button I nP PE cd oF Press SQ button to enter Configuration Menu Pt100 RTD 2 wires Input p E 3H Pttoorto 3 wires E Cc 1 Thermocouple J c Thermocouple K c E Thermocouple T Ec E Thermocouple E ke Thermocouple S c r Thermocouple R Er nm Thermocouple N Er c Thermocouple C Ec L Thermocouple L Ec H Thermocouple x cati JEG gt Dr Celsius Temp Config Degrees GE Fahrenheit a PRHESH Jo 1 Resolution Pt100 RTD res JO 01 Resolution eras E oF FSS an BEBE Offset Ecuoc gt Thermoc CJC on On break
23. udr Hardware underrange The thermocouple signal is lower than minimum readable signal 30mV h oVr Hardware overrange The thermocouple signal is higher than maximum readable signal 80mV d udr Display underrange The Pt100 RTD is shortcir cuited hoLd The instrument is showing the value present when the hold function was activated Hold function is active Min The instrument displays the minimum displayed value in memory The minimum visualization is active MAX The instrument displays the maximum displayed value in memory The maximum visualization is active brk The instrument displays brk with either 9999 or 9999 when 1 resistance measured is higher than 390 Ohms higher than 850 C for PT100 RTD measure or 2 in case the third wire ohm is higher than 15 Ohm or 3 thermo couple measure is open circuit Err 1 Err 2 The instrument has detected an installed option but was unable to communicate E 101 nized Password incorrect Option is installed but the type can not be recog FEMA ELECTRONICA Page 9 User s Manual M40 T 1 13 Information menu 1 13 1 Information menu A Press UP button to enter Information Menu eon F H H H H Configuration Sensor type Vv HHHH C or F AH AAG Maximum MI tito 0666 Minimum Memory o

Download Pdf Manuals

image

Related Search

Related Contents

“SHARPE Interface” User`s Manual Version 1.01  LED Wi-Fi Controller - Jinan USR IOT Technology Limited  Système manuel Prodigy HDLV Generation II  Sony VAIO SVE17125CX  Heating Mantles - Stuart Equipment  Nagoya-City Nantes Oslo Padova Paris  Neil Pryde RAF Supersonic User Manual  JUDO D-Soft  Professional power amplifier User manual  Operating Instructions  