1. 9 TECHNICAL SPECIFICATIONS 10 RELATIVE SPECTRAL 11 9 RECOMMENDED LEVELS OF 12 10 13 11 SERVICE REPAIRS 13 12 LIMITED TWO YEAR 14 anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 1 Introduction Thank you for purchasing a M110 Light Meter from Anaheim Scientific With this meter you can measure light coming from fluorescent metal halide high pressure sodium and incandescent sources Giving units in both Lux and Foot candles the M110 is durable reliable and easy to use 1 1 The M110 Features Measures all visible light sources Measuring intensities of illumination in Lux or Foot candles Overload indication LCD screen will show OL on the upper left hand corner Low battery indication Sampling Rate 2 5 times per second for digital display Spectral response close to CIE luminous spectral efficiency Cosine Angular corrected Data hold HOLD Maximum Average Minimum Hold MAX MIN Zero adjustmen
2. Press the button again for MIN the minimum value Press again to go to MAX again or press for more than 1 second to leave this mode 6 5 Data Hold Button Freezes the reading present on the LCD screen at the moment the button is pressed 6 6 Auto Power Off Feature When the LCD symbol is showing the Auto Power Off feature is engaged To save battery life the meter powers down automatically after approximately 12 minutes of inactivity To turn this feature on or off press and hold the Power Button 2 for more than 2 seconds anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 6 7 Storage of the Meter When the meter is not in use please keep the photo detector cover in its place to avoid the photo diode from wearing out When the meter not to be used for a long time please remove the batteries Avoid keeping the meter in a place of high temperature and humidity 6 8 Battery Replacement WARNING If the symbol appears the LCD please replace the battery immediately Remove the battery cover Replace the battery Install the battery cover ae i anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 10 7 Technical Specifications Display 4000 count maximum display 3999 Sensor Silicon photodiode and filter Measuring 400 4000 40000 400000 Lux Rang
3. 000 4 2 2008 IEC 61000 4 3 2006 2007 Meets JIS 1609 1993 and CNS 5119 4 Product Contents and Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial physical inspection should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any external damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If damage to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection Forward a report of any damage to the agent through which the unit is procured anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 Retain the original packing in case subsequent repackaging for return is required Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included in this package are M110 Meter User Manual Carrying Case 2x AAA Batteries 5 Device Description Photo detector cover Photo detector Display LCD Lux Fc button Calibration and ZERO button Data hold button 7 Maximun Average Minimum button 8 Power Button ON OFF gr a o N SS D anaheimscientific com Technical dat
4. AKNAHEIM SCIENTIFIC User Manual Model M110 Mini Light Meter Table of Contents 1 INTRODUCTION 3 1 1 The 3 1 2 The M110 4 2 SAFETY 4 3 COMPLIANCE 5 4 PRODUCT CONTENTS AND 5 5 DEVICE DESCRIP 6 6 DEVICE lt 7 6 1 Power EU UO E E 7 6 2 LUX FC BUON sirenen ea EE E ESS 7 6 3 CAL ZERO BUON a a Eai 7 6 4 IMINO GBS es 8 6 5 Data Hold Button 8 6 6 Auto Feature 8 6 7 Storage of the Meter 2 2 9 6 8 Battery
5. a subject to change without notice Anaheim Scientific 2013 20130412 6 Device Operation 6 1 Power Button Press the 2 button more for than 2 seconds to power on the meter Press the button again and the meter will immediately turn off 6 2 LUX FC Button Select the units you will use Lux or Foot candle 6 3 CAL ZERO Button Calibration of 1000 LUX The M110 meter must be calibrated with a 1000 Lux light source 2856 K Have your light source ready Press CAL button and POWER button for more than 2 seconds and the LCD will display CAL Place the photo dectector as close to the light and with as little angle as possible as shown Light Source 0 degree for more than 2 seconds and the meter will shut down Your meter is now calibrated anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 ZERO Button With the meter on and the cover attached press the ZERO button to reset the meter Do this anytime the meter shows a value other than zero while the cap is on If the light sensor cap is not properly attached CAP will be shown on the screen 6 4 MAX MIN AVG Button Press the MAX MIN button MAX will appear and the highest reading since the meter was turned on will stay showing Press the button again to see AVG the average value This will change as time goes on and the average value changes
6. ce is required and include the anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 14 return shipping information name address and telephone number lf the unit is in warranty please provide the following proof of purchase or copy of the original invoice lf the unit is out of warranty prepayment is required by Check Money Order or Credit Card Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific ATTN Service Repair 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 12 Limited Two Year Warranty Scientific warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 15 Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt hel
7. e 40 400 4000 40000 Footcandles Angle deviation 3 2 AAA Batteries 3 3Lux 0 500Lux 3 above 501 Lux Calibrated to standard incandescent lamp 2856 K 8 other visible light source Battery life About 200 hours Conditions Conditions Dimensions 133 H x48 W x23 D mm 5 3 AUV XOA D inch Weight 280g bater anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 11 8 Relative SPECTRAL Sensitivity The deviation from the comparative standards for luminosity is determined by JIS standard C 1609 1993 Peak sensitivity wavelength 550 Typ 23 WY 380 440 500 560 620 680 740 RELATIVE SENSITIVITY WAVELENGTH nm CIE Luminosity Function anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 12 9 Recommended Levels of Illumination Suitable levels of illuminance According to the OSHA Regulation 1926 56 a Candle offices General construction plant and shops e g batch plants screening plants mechanical and electrical equipment rooms carpenter shops rigging lofts and active store rooms mess halls and indoor toilets and workrooms General construction area lighting Indoors warehouses corridors hallways and exitways Tunnels shafts and general underground work areas General construction areas concrete placement e
8. p us better serve you please complete the warranty registration for your new instrument via our website www anaheimscientific com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 16 AKNAHEIM SCIENTIFIC 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 2013 Anaheim Scientific anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412
9. t ZERO Auto power off and disable function Auto ranging anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 1 2 The M110 Applications Warehouses factories office buildings restaurants schools library hospitals photographic video parking garages museums art galleries stadiums building security etc 2 Safety Summary CAUTION and effective usage of this meter Do not operate the meter in an environment filled with combustible gas liquids dust or fibers In order to avoid reading incorrect data please replace the battery immediately when the symbol f appears on the LCD In order to avoid damage caused by contamination or static electricity do not touch the circuit board before taking adequate precautions Operating Environment Indoors use This instrument has been designed for usage within an environment of pollution degree 2 Operation Altitude Up to 2000M Operating Temperature amp Humidity 5 C 40 C 0 80 RH Storage Temperature amp Humidity 10 C 60 C 0 70 RH anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 3 Compliance Statements Caution This symbol indicates that the equipment and its accessories are subject to special collection and disposal procedures Complies with EMC EN61326 1 2006 Complies with IEC 61
10. xcavation and waste areas access ways active storage areas loading platforms refueling and field maintenance areas anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 13 10 Maintenance This is a precision instrument To guarantee its performance be sure to use it or keep it stored within the suitable environmental conditions given in the Safety Summary and Technical Specifications Be sure to turn it off after use To store the instrument for an extended period of time remove the batteries to avoid any damage to its inner components 11 Service Repairs Calibration The following are instructions regarding policies for servicing repairing or calibrating Anaheim Scientific products Turnaround time is usually less than ten 10 working days unless expedited service is requested and pre arranged Send an email to service anaheimscientific com requesting an RMA number specifying your request for either service repair and or calibration with your product s model number Once you receive a reply from service anaheimscientific com you will be asked to ship prepaid to the address below Package the unit carefully using filler or bubble wrap and if possible ship in the original box Ship each unit separately Anaheim Scientific is not responsible for any shipping damage that may occur Include a packing list with each unit shipped stating what type of servi
Download Pdf Manuals
Related Search
Related Contents
WorkCentre-Serie 7800 – Multifunktionsdrucker Elica 70cc Island Evoque Amana Gas & Electric Dryer-1 Tucor Cycle Manager User Manual (TWC Controllers) 医療機器の添付文書の記載要領(細則)について FRED 3 User Manual - JonAcc Ambulance Services Halogen notice Vanne à boule rotative Fisherr pour Pipeline 【79630】AQ-S33 アクアビーズ キラキラビーズジュエルEX Copyright © All rights reserved.