Home

Product Data Sheet

image

Contents

1. 2 Modular Jack When communication with computer PLC and control device directly without using a hub in this case cross cable is used Cross cable Remark 1 Ethernet setting Ethernet IP sets from XGT Panel the communication parameter of the PLC controller set from the XP Builder 2 1 1 connection When it will not be able to a LAN cross cable is convenient to send receive project data 3 Wiring precaution Please use the Plug Cover when wiring Ethernet cable 5 2 Tool cable specification and wiring ptm sero Cable specification gt Name PMC 310S Using for download and upload the project program gt Length flexible tube type 1 m gt Directly connect to PC and XP Panel gt Providing the option production Configuration and wiring 5 3 RS 232C cable configuration and wiring p tem O Deseription S Cable gt Please use the AWG24 type specification gt Keep the length of cable within 15 m gt Recommends to using the shielded cable Connect to PLC or control devices 1 1 communication gt Pin arrangement of XGT Panel s connector gt Connector type D Sub 9pin Male Configuration and wiring Remark 1 Wiring precaution Because of male connector for XGT Panel Please use D SUB 9P female for the connector Because PLC and control devices are different wiring methods please refer to communication manual for more detail 5 4 RS 422 485 cable configuratio
2. DC XP30 TTA B DC XP50 TTA B DC module For safety precautions on the HMI system refer to the XGT Panel user manual gt The precautions are divided into 2 sections Warning and Caution Each of the meanings is represented as follows N Warning N Caution gt The symbols which are indicated in the HMI and User s Manual mean as follows If violated instructions it can cause death fatal injury or considerable loss of property If violated instructions it can cause a slight injury or slight loss of products A N This symbol means paying attention because of danger of injury fire or malfunction JIN This symbol means paying attention because of danger of electrical shock gt Store this datasheet in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Do not contact the terminals while the power is applied Risk of electric shock and malfunction Protect the product from being gone into by foreign metallic matter Risk of fire electric shock and malfunction Do not charge heat short solder and break up the battery It can cause injury and fire by explosion and ignition Be sure to check the rated voltage and terminal arrangement for the module before wiring work Risk of electric shock fire and malfunction Tighten the screw of terminal block with the specified torque range If the terminal screw looses it can cause fire and electric shoc
3. HMI or repair the troubled parts free of charge except the following cases 1 The troubles caused by improper condition environment or treatment except the instructions of LSIS 2 The troubles caused by external devices 3 4 5 The troubles caused by the reason which exceeded the expectation from The troubles caused by remodeling or repairing based on the user s own discretion The troubles caused by improper usage of the product am science and technology level when LSIS manufactured the product 6 The troubles caused by natural disaster 3 This warranty is limited to the HMI itself only It is not valid for the whole system which the HMI is attached to
4. to be affected by noise and magnetic field Before handling the product Before using the product read the datasheet and the User s manual through to the end carefully in order to use the product efficiently po Name Ede XGT Panel Manual 10310000867 XGT Panel Communication Manual 10310000857 XP Builder Manual 10310000876 1 Introduction XGT Panel as HMI Human Machine Interface watches and controls the condition of the PLC Inverter and other instruments XGT Panel series provide the function which is various and a stable efficiency 2 General Specifications No Item Specifications Standard Operating 00 50 C temp Storage temp 20 C 60 C Operating wes i l 10 85 RH Non condensing Storage a 0 j humidity 10 85 RH Non condensing For discontinuous vibration Number Amplitude Sis Hz 3 5mm Vioration oe oew each10 times in X Y Z IEC 61131 2 direptlons cow Max impact acceleration 147 m 15G Shocks Authorized time 11 ms Pulse wave Sign half wave pulse Each 3 times in X Y Z directions PAUE WaVe 1 000V LSIS Standard impulse noise Electrostatic f l IEC 61131 2 discharging Voltage 6 kV contact discharging IEC 61000 4 2 Noise IEC 61131 2 Radiated IEC 61131 2 IEC 61000 4 3 field noise l Clase Power Communication a Beera module interface Eo aS nose f Voltage 2kv aw No corrosive gas or dust conditions Operating a 2 000
5. DATA SHEET LS Human Machine Interface XP30 BTA B DC XP30 TTA B DC XP50 TTA B DC XGT Panel Series ayer When using LSIS equipment thoroughly read this datasheet and associated manuals introduced in this datasheet Also pay careful attention to safety and handle the module properly Store this datasheet in a safe place so that you can take it out and read it whenever necessary LS Industrial Systems Co Ltd Davis Controls my Davis Controls Ltd ts the authorized distributor of LOIS equipment and control solutions throughtout Canada Founded in 1933 Davis Controls represents a strong and balanced portfolio of world class products From head office facilities located in Oakville Ontario Davis Controls connects customers seeking high quality automation solutions with global manufacturers of state of the art products You can contact us at Toll Free Canada 800 701 7480 Toll Free USA 800 388 4159 Email infoiidaviscontrols com Website wwiw daviscontrols com Thank you for your business and your interest in LSIS Ky Y solutions LS constantly endeavors to improve our products so that information in this datasheet is subjected to change without notice 10310000879 O Safety Precautions gt Safety Precautions is for using the product safe and correct in order to prevent the accidents and danger so please go by them gt The precautions explained here only apply to the XP30 BTA B
6. d when power is on 2 LCD Backlight replacement In XP50 TTA B DC LCD backlight is replaceable But in XP30 BTA B DC XP30 TTA B DC LCD backlight is not replaceable because LCD and backlight are all in one type 4 Part names of functions Part names of functions are as described below Description 1 Analog touch panel User touch input Indicates operation status of module Normal RUN status monitoring downloading the project data LED Status Initializing mode when booting Error occurs Red communication error project data error _Panel fixed part_ Panel fixed part XGT Panel is fixed at panel by bracket 1 Logging recipe screen data backup 2 Upgrade of Windows CE is available Power connection It consists of power input and FG terminal terminal It consists of 2 ports 1 USB memory connection logging recipe screen data backup USB interface 2 USB memory connection project data transmission backup 3 User interface connection use of mouse keyboard 4 Printer connection printing is available Extension port Extension module installation Reset switch Hardware reset switch RS 232C interface l 1 Project data transmission Tool interface 2 Logging recipe alarm screen data backup 3 Machine software upgrade Module setting switch Reserved A setting Normal operation basic setting B setting When upgrading Windows CE No 3 A setting Use of Watchdog basic setting No u
7. k Use the HMI in an environment that meets the general specifications contained in this datasheet Risk of electrical shock fire erroneous operation and deterioration of the HMI Be sure that external load does not exceed the rating of output module Risk of fire and erroneous operation Do not use the HMI in the environment of direct vibration Risk of electrical shock fire and erroneous operation Do not disassemble repair or modify the HMI Risk of electrical shock fire and erroneous operation When disposing of HMI and battery treat it as industrial waste Risk of poisonous pollution or explosion Precautions for use gt Do not use hard or pointed objects to operate the touch screen panel since it can damage the panel surface gt Make sure that the FG terminal is grounded with class 3 grounding which is dedicated to the HMI Otherwise it can cause disorder or malfunction of HMI Pore rire rire ir irtrr irri ririr irri iii iii aa oree lt Best gt lt Good gt lt Bad gt gt Connect expansion connector correctly when expansion module is needed gt Do not detach PCB from the case of the module and do not modify the module gt Turn off power when attaching or detaching module gt Cellular phone or walkie talkie should be farther than 30cm from the HMI gt Input signal and communication line should be farther than minimum 100mm from a high tension line and a power line in order not
8. m 6 562ft or less degree Cooling 3 XGT Panel Function Specifications XGT Panel s function specification is as follows Left Right 45 deg Left Right 70 deg Left Right 65 deg Upper 40 deg Upper 50 deg Upper 50 deg Lower 20 deg Lower 70 deg Lower 60 deg 7 electromagnetic 27 500 MHz 10 V m Display angle CCFL CCFL Replacement is Backlight Replacement is unavailable available Supporting automatic On Off Supporting automatic On Off convest a Analog Magnetic buzzer ARM920T 32bit RISC 200MHz Graphic accelerator Hardware Accelerator 32MB Operating RAM 64MB Backup RAM 512KB Backup type Date Hour data and Logging Alarm Recipe data About 3 year When 25 C 1 channel IEEE802 3 10 100Base T 2 channel USB 2 0 printer USB memory stick driver is available 2 channels 1channel RS 422 485 mode 1 slot Compact Flash Animation GIF format is available Recipe Available Data logging Available Script executor Available AJOWS Standard certification CE UL MIC Type XP30 BTA B DC XP30 TTA B DC Degree of protection IP65F 181 x 140 x 66 5 Panel cut mm 156 x 123 5 Input voltage V DC24V XP50 TTA B DC 240 x 174 x 73 228 5 x 158 5 W l Weight kg 1 Battery operation and life Battery is used to reserve backup data and RTC date time when power is off Because battery is used when power is off battery is not consume
9. n and wiring gt Please use the UL Style 2464 AWG22 gt Keep the length of cable within 500 m gt Recommends to using the shielded cable Cable specification Connect to PLC or control devices 1 1 1 N communication gt Pin arrangement of XGT Panel s connector gt Connector type D Sub 9pin female Configuration and wiring 1 Set terminal resistance of the XGT Panel 2 Because of female connector for XGT Panel Please use D SUB 9P male for the connector 3 Please connect no 4 TX with no 8 RX no 5 TX with no 9 RX 6 Power input wiring 6 1 DC power wiring XP30 BTA B DC XP30 TTA B DC and XP50 TTA B DC are connecting to DC24V Frame Ground 6 2 Power terminal and wire specification unit mm Wire specification 1 5 AWG16 2 5 AWG12 Less than i Less than 6 00mm 6 00mm Power terminal Remark 1 When the regulation of power is bigger than provision use the constant voltage transformer 2 In case power has much noise use the insulation transformer 3 Separate the XGT Panel s power from the main circuit high voltage large current cable I O signal cable If possible install at a interval of more than 100mm 7 Installation 7 1 Panel cut unit mm 7 2 Panel installation Keep the distance of 100 mm between XGT Panel and panel per each direction 100 100 100 7 3 Fixation The bracket is included in the product unit mm 1 Precau
10. se of Watchdog A setting RS 422 485 terminal resistor setting 1200 No 4 B setting No use of RS 422 485 terminal resistor PARRIN nee Using the extension module fixing hall fixing hall RS 422 485 port RS 422 485 PLC control machine communication RS 232C port RS 232C PLC control machine communication Ethernet 10 100 BASE T 1 Project data transmission Ethernet port 2 Logging recipe alarm screen data backup 3 Machine software upgrade 4 PLC control machine communication FG terminal FG terminal hole for extension module 1 lf AC power is applied into the product for DC power It may cause damage or fire Be careful of connection 2 XP30 BTA B DC XP30 TTA B DC and XP50 TTA B DC modules must be use DC 24V power When using the product check the label in the back of the product 3 Using the no 5 FG terminal for the module s frame ground And Using the no 15 FG terminal for the extension module s frame ground 4 There is prevention sheet in prevention of battery discharge In order to use backup remove the prevention sheet 5 Communication cable configuration and wiring method 5 1 Ethernet cable configuration and wiring Item Description Cable gt Type UTP FTP STP cable Specification gt Specification CAT 5 Enhanced CAT 5 CAT 6 When communicating through LAN connected to network equipment like a hub direct cable is used for communication to PLC control devices Direct cable
11. tion for installation This machine should be install within 0 50 C otherwise the screen may be changed or cause malfunction Because the product can be affected by dust use the anti vibration rubber packing Don t touch the terminals while power is on otherwise it may cause electric shock or erroneous operation 8 Dimension 8 1 XP30 BTA B XP30 TTA B dimension 000000 N Curt Tea 140 0 1235 0 56 5 00000 77 QOOOD0000 Q0000000000 00 rec TES N 155 5 165 5 8 2 XP50 TTA B dimension unit mm comment Mil DOOUDOOCIO DOQ00000000000000000 1000000000 iT 174 0 QOQU00000000000000 100 0 158 0 240 0 7 0 73 0 il QOODO0O000 QO00000 0000000000000 DO00000000 9 Warranty 1 Warranty period LSIS provides an 18 month warranty from the date of the production 2 Warranty conditions For troubles within the warranty period LSIS will replace the entire

Download Pdf Manuals

image

Related Search

Related Contents

Quick Start Guide Guide de démarrage rapide Kurzanleitung  R&S®FSE-K10 User Manual  Westinghouse 7861965 Installation Guide  PREGAO 13 QUADROCOMANDO EEH4 EEJ2    言葉にしたことが、現実になるマイク  PASTRY CREAM CREMA PASTELERA  Call-pick function When speakers is connected to your  Philips Remote control RC4731  Manual de Usuario de la Pagina Jovenes Investigadores  

Copyright © All rights reserved.
Failed to retrieve file