Home
MM1010
Contents
1. oils steam or other unwanted process byproducts EMC Guidelines 1 Use proper input power cables with shortest connections and twisted type 2 Layout of connecting cables shall be away from any internal EMI source MAINTENANCE 1 To avoid blockage of ventilation holes clean the equipment regularly using a clean soft cloth 2 Do not use Isopropyl alcohol or any other organic solvents for cleaning WIRING INSTRUCTIONS AX CAUTION 1 To prevent risk of electric shock power supply to the equipment must be kept OFF while wiring 2 Terminals and electrically charged parts must not be touched when the power is ON 3 Wiring shall be done strictly according to the terminal layout provided in the operating manual 4 Use lugged terminals to meet M3 5 screws 5 To eliminate electromagnetic interference use short wire with adequate ratings and twists of equal size 6 The power supply connection cable must have a cross section of 1sq mm or greater and insulation capacity of atleast 1 5KV FUNCTIONAL DETAILS MM1010 is a PLC with built in HMI The user can configure the product using SELPRO software SELPRO has two sections 1 Ladder logic programming section 2 Selec Machine Interface used for configuration of HMI This software is provided with the product For details of the software and configuration method please refer to its user manual with the product The display shows pages as configured by the user in
2. which is 9303 Change communication settings as per target settings Click on the Download button to start downloading NOTE Communication settings show default values Downloading would take place only if target comm unication settings and communication settings of project match Specifications subject to change as development is a continuous process Selec Controls Pvt Ltd India Tel 91 22 28476443 1882 Fax 91 22 28471733 Toll free 1800 227 353 Website www selec com E mail sales selec com Document name Operating 1004 MM1010 230V OP 256 VO2 Page 2 of 2
3. MM1010 230V 48x96 Operating Instructions e Upto 8 Digital inputs e Upto 5 Relays Digital outputs e One analog input SPECIFICATIONS Display No of Keys No of Configurable Keys 3 digit 4 4 digit so _ DIGITAL INPUT No of Digital Inputs Input Type Input Voltage Range Response Time Inputs other than fast counter 11 28 VDC abs max 30 VDC For 8DI IXO IX1 2 inputs 1 ms without debounce Others 10 ms with debounce 2 kV DIGITAL OUTPUT Relay No of Relay Outputs Relay NO Type Contact rating Response Time 5 NO type 5 A resistive 240 VAC ANALOG INPUT No of Inputs Type Input TC RTD 0 10V 0 20 mA User selectable for ladder program amp Method HMI E N a To Enter into internal menu In Internal menu system Data memory 16K settings digital input communication settings Maximum 5000 can be viewed No of Objects as per memory FUNCTIONAL BLOCKS k LED LED Bank A Display 1 BankB Display 2 Display 3 FUNCTIONAL SPECIFICATIONS FRONT KEYS DESCRIPTION l Windows based software General key description internal menu Display 1 Display 2 Display 3 LED Bank A LED Bank B Programming 1 Scan ms Digital Digital rate in milli Inputs Outputs sec with a Status Status least count DIO to DI7 DOO to DO4 of 1ms menu Press ENT to go to To view system settings SCN Minimum Scan Time 200 psec digital input and o
4. N S ST MM1010 MM1010 230V Accessories ereraa Order Code Communication cable ACH 001 TC RTD1 ANA IP l ANAIP TC RTD2 IP6 IP5 IP4 IP3 IP2 IP1 0 0 0 0 0 0 0 5 Windows based software for ladder programming ACD 003 RS485 to RS232 Document name Operating 1004 MM1010 230V OP 256 VO2_ Page 1 of 2 MM1010 4 SAFETY PRECAUTIONS fo This manual is meant for personnel involved in wiring installation operation and routine maintenance of the equipment All safety related codifications symbols and instructions that appear in this operating manual or on the equipment must be strictly followed to ensure operator and instrument safety Any misuse may impair the protection provided by the equipment CAUTION Read complete instructions prior to installation and operation of the unit AA CAUTION Risk of electric shock INSTALLATION INSTRUCTIONS CAUTION 1 This equipment being built in type normally becomes a part of the main control panel and the terminals do not remain accessible to the user after installation 2 Conductors must not come in contact with the internal circuitry of the equipment else it may lead to a safety hazard that may endanger life or cause electrical shock to the operator 3 The equipment shall not be installed in environmental conditions other than those specified in this manual 4 Since this equipment forms part of the main control
5. Selec Machine Interface An internal window is provided to the user to view status of physical inputs physical outputs system settings and communication settings No editing is possible in this view Note At least one page has to be defined in HMI At power ON the control would go to the first page or the page sequence defined by user or the page defined under STR would appear COMMUNICATION While making communication connections make sure that the power supply to the unit is OFF MM1010 has one serial RS485 communication port Serial communication port is used 1 To download application program from PC to PLC 2 For Online simulation 3 For Standard modbus communication of all the user defined variables in ladder PLC acting as a slave device The modbus variable table is generated by the ladder editor and can be viewed on demand Downloading application programs For downloading application program from the PC to the PLC follow the steps given below in sequence Step 1 Make the necessary connection between MM1010 RS485 to RS232 converter and PC Step 2 Save the ladder to be downloaded in the PLC and its corresponding HMI and compile using the Compile option present in Menu Bar Step 3 Select the download option from Communication option from Menu Bar A downloader window as shown below appears Password Com Port Baud Rave Parity Stop Bits Enter password for downloading
6. panel its output terminals get connected to the host equipment Such equipment shall also comply to EMI EMC and safety requirements like BSEN 61326 1 and BS EN 61010 5 Thermal dissipation of equipment is met through ventilation holes provided on chassis of equipment Obstruction of these ventilation holes may lead toa safety hazard 6 The output terminals shall be loaded strictly as per the values range specified by the manufacturer ELECTRICAL PRECAUTIONS DURING USE Electrical noise generated by switching of inductive loads can create momentary disruption erratic display latch up data loss or permanent damage to the instrument To reduce noise A Use of MOV Snubber circuits across the load is recommended 1 Snubber Part no APRC 01 2 MOV Part no AP MOV 03 ELECTRICAL PRECAUTIONS DURING USE CONTD Typical connections for loads For load current lt 0 5A L Snubber N For bigger loads use interposing relay contactor NOTE Use snubber as shown above to increase life of internal relay of temperature controller B Use separate shielded wires for inputs ia MECHANICAL INSTALLATION Panel cutout Outline dimensions in mm dimensions in mm 2 Remove the clamp from the PLC 3 Fix the unit into the cutout Insert the clamp from both sides and tighten the screws A CAUTION The equipment in its installed state must not come in close proximity to any heating sources caustic vapors
7. utput SET status when in internal previous screen Timer On Delay Off Delay Operational Modes Pulse Special Up Down To view communication 1 8N2 Least count 01 sec Timer 10 ms settings digital input and Slave ID Word output status when in Length internal menu Parity i Sec Min Hr Day Min Press ENT to go to a es Sec Hr Min Day Hr previous screen Stop Bits pHepiay EONA Hr Min Sec Day Hr Min Sec ENT To Exit from internal menu User defined HMI page Up Counter Down Counter 8 digits Counter Up Down Counter Key operation in user defined HMI modes Other Blocks PID Control Analog input User defined HMI Mode Edit Mode Accept data entry task S ey aati User Configurable Allows switching between sign ve or ve for Communication Ports RS485 ports slave Dual key definition is also possible signed variables Communication MODBUS RTU User configurable Moves the cursor to the right by one digit Protocol Dual key definition is also possible Memory Retention User configurable Decrements the digit of the parameter in edit Dual key definition is also possible mode by 1 Supply Voltage 90 270 VAC DC aes o User configurable Increments the digit of the parameter in edit Operating 0 to 50 C Temperature Siemae 0 to 60 C A Dual key definition is also possible mode by 1 agnor deneing Not User Configurable Saves the selected edited parameter IS TERMINAL CONNECTIONS li ORDERING INFORMATIO
Download Pdf Manuals
Related Search
Related Contents
実用基準分銅管理ソフト FKSシリーズ Alkaline Battery Pack for AirChek XR5000 Sample Pumps Operating Manual do proprietário Rangiersystem für Caravans MANUEL D`INSTALLATION ET DE SÉCURITÉ Avid Video Peripherals Guide Horizon FCJJ-16 Copyright © All rights reserved.
Failed to retrieve file