Home
SLP-C35 User`s Manual
Contents
1. Double click the SLP C35PRO SDC35 36 icon on the desk top or click Start button at the lower portion of the screen and select Programs SLP gt SLP C35 gt gt The loader is started up and the menu window is displayed Note e For the operating system details and the mouse setup refer to User s Manuals provided with Windows Click ES icon at the top right of the screen The operation is the same by selecting the Menu Quit 2 5 Chapter 3 SETTING UP 3 1 Setup Function mM Overview The setup function allows you to set the various parameters about 10 to 70 constants required for operation and write these parameters to the SDC15 25 26 35 36 so that it functions according to your particular control requirements When the SDC15 25 26 35 36 is used for the first time it will not function as required unless it is set up by using this setup function Parameters such as SP set point and control constants PID values that are changed relatively frequently while the SDC 15 25 26 35 36 is running can also be set from the monitor function screen By the setup function parameters that hardly need changing later once they are set are saved to file in list format before the SDC 15 25 26 35 36 is run and the saved file is called up and written to the SDC 15 25 26 35 36 in a single operation mM Screen explanations Menu screen Menu Help Setup Monitor SLP C35 Standard 2 0 8 C 2003 Yamatak
2. URL http www ratocsystems com products subpage cf60 html Japanese e USB adaptor USB RSAQ3 manufactured by IO DATA DEVCE INC URL http www iodata jp prod mobile serial 2004 usb rsaq3 Japanese Operation confirmed personal computer IBM s Thinkpad A31 When connecting the USB cable check the port No The port No may vary depending on the USB cable connection position o Handling Precautions e Before starting up loader quit all other applications If you start up loader while another application is running loader may not function Also set the power save setting infrared communications and screen saver to OFF e Make sure that the Decimal symbol has been set to for Control Panel Regional Settings Number If it has been set to other character the loader cannot correctly function 1 2 Chapter 1 INTRODUCTION mM Hardware configuration General configuration SLP C35 SDC15 25 26 35 36 ow CIS SSS SSS SSS SS LLI IAL Configuration with CMC10B L e When connecting 31 units or less CMC10L a AN CERSSIIARo CRA SIS DI CIA LAS CRAE SNS 2 o gt COS Max 31 units e When connecting 32 units or more CMC10L_CMC10B CMC10B CMC10B LY AA ROARK OR CY en IA EIX LA aaa nanan AA gt Max 31 units Max 31 units Max 31 units Note e The CMC10B allows up to 31 units to be connected to a hos
3. A My Documents gt e amp ff EJ My Pictures File name c35 Save as type SLP C35file c35 g Cancel L h 2 Enter the file name and click Save button 3 7 Chapter 3 SETTING UP Step 6 downloading the setup Write the set parameters or parameters called up from a saved file to the SDC15 25 26 35 36 1 Use the special loader cable to connect the personal computer to the SDC15 25 26 35 36 body 2 Turn the SDC15 25 26 35 36 ON 3 Click HE icon The operation is the same by selecting Communication gt Write SLP gt SDC in the pull down menu gt gt The message Writing is going to be executed is displayed 4 Click OK button gt gt This starts writing of the setup parameters During writing the message Please wait is displayed When writing ends the message Normal end is displayed B Handling Precautions e If writing fails the message Communications error has occurred is displayed If writing is not possible refer to gt Chapter 5 TROUBLESHOOTING 3 8 Chapter 4 MONITORING 4 1 Monitor Function mM Overview The loader exclusively for the SDC15 25 26 35 36 is used for monitoring SDC15 25 26 35 36 operation To enter the monitor screens click Monitor in the menu screen The loader has the following two monitor screens e Numeric Monitor screen This screen is for performing operations such as changing setups or switching modes e Numeric display of the vari
4. EV2 C 33 EV3 REV C 14 EV2 C 33 EV3 REV 15 1 EV3 C 40 EV4 REV C 15 1 EV3 C 40 EV4 REV C 15 EV3 C 40 EV4 REV C 416 EV4 41 EVS REV C 16 EV4 C 41 EVS REV C 46 EV4 C 41 EVS REV C 17 EV5 C 42 EV6 REV C 17 EV5 42 EV6 REV C 17 EV5 42 EV6 REV C 18 EV6 C 43 EV7 REV C 18 EV6 43 EV7 REY C 18 EV6 43 LEV7 REV C 19 EV7 C 44 EV8 REV CO 19 EV7 C 44 LEV8 REV C 19 EV7 C 44 EV8 REV 20 EV8 CO 45 COMM DH REM 20 EV8 C 45 COMM DH REX 20 EV8 C 45 COMM DH REM 21 COMM DM C 46 COMM DI2 REV 21 COMM DH C 46 COMM DI2 REV 21 COMM DI 46 COMM DI2 REV 22 COMM DI2 47 COMM DIS REX 22 COMM DI2 47 COMM DIS REX 22 COMM DI2 47 COMM DIS RE 23 COMM DIS C 48 COMM DI4 RE 23 COMM DI3 C 48 COMM DI4 RE 23 COMM DI3 C 48 COMM DIREY C 24 COMM DI4 C 24 COMM DI4 C 24 COMM DI4 Trend stop trigger o Trend save folder C Program Files SLP SLPC35 Trend trigger is only in numeric monitor mode Cancel When setting up the trend triggers the trend can be started and stopped according to the status of the individual monitor The trend trigger setup is valid only while the individual monitor is running When setting up the trend save triggers the trend can be saved according to the status of the individual monitor The file is saved into a specified trend save folder in the TREND Y Y Y Y MM DD HH MM SS CSV format e Starting the data sampling W
5. Initializes the cell size f Cell size adjust Makes the cell size matched with the window Communication aLF Read SDC15 25 26 35 36 gt SLP Reads the device data Ctrl R 7 R Write SLP gt SDC15 25 26 35 36 Writes the data to the device Ctrl W En VV Ln standard Od Option SiS User Function F User function Displays the user function registration screen User function clear Clears the contents of the user function registration Type Setting Changes the type setup Ctrl T Environment Setting Changes the environment setup Ctrl E rep a Option 3 Chapter 3 SETTING UP 3 2 Method of Setup Configure setup in offline state without connecting the cable to controller Click the Option on the menu screen Set up in the following steps The following tasks are performed Step 1 Setting up the loader type Step 2 Initialization clearing previous setting values Step 3 Setting up the environment Step 4 Setting up SDC 15 25 26 35 36 parameters Step 5 Saving setup data Step 6 Downloading the setup Un Handling Precautions e Operations in steps 1 to 5 are required before the setup parameters are entered on the SDC15 25 26 35 36 Be sure to perform these steps Otherwise the SDC15 25 26 35 36 may be set up incorrectly For example the required setup items may not be displayed or unrequired items may be displayed Step 1 setting up the loader type Set up the loader type to match the
6. SDC 15 25 26 35 36 model number 1 Click FR icon The operation is the same by selecting the Option Type Setting or the Ctrl T keys gt gt The Type Setting dialog box is displayed Type Setting I Basic Model No Mountine 4 PV Input C15 mask size 48x48 G T Panel mounting O C25 mask size 48x96 Output Gea cles 2026 mask size 96x96 RO Relay amp AC100 to 240 O D D024V O C35 mask size 48x96 O R1 Position propotional MFB Option 1 086 mask size 96x96 Q W Voltage pulse O18EV O VGC Voltage pulse Current 23EV AUX Current CIGTVVUA2I XX O33EV AUX Voltage D Volt It O VD Voltage pulse Voltage 4 2EVdndependent ViVoltage pulse Voltage pulse O 52EVindependent t AUX C t O COCurrent O62EVOndependent AUX Voltage O CC Current Current Option 2 OcD Current Voltage O O None 1 CT2 D4 DO Volt Pace O 20 To DM4RS485 DD Voltage Voltage 3 CT2 D2 RSP 4 CT2 DI2 RSP RS485 2 Set the mounting type control output input type power voltage and additional functions 3 Select from the selection items for each setting item 4 Click OK button Note e Click the Read button to read out product data This method prevents the downloading of a wrong parameter by the model number setup error 3 4 Chapter 3 SETTING UP B Handling Precautions e Type set here is the setting for internal use on the loader The model number of the SDC15 25 26 35 36 will not change
7. communications port Select the port from the selection items 3 Set the font size Select the front size from the selection items 4 Click OK button Un Handling Precautions e Normally use Port COM1 Even if another communications port can be selected it sometimes cannot be used depending on its shape e Normally use Use Loader Cable Step 4 Setting up SDC15 25 26 35 36 parameters Move the cursor to the target channel of each setup item and perform the following operations e When the setting is a numerical value Enter the numerical value and press Return key e When the setting is selected by a number Press the right mouse button on a setting item The list of settings you can select will appear Select a desired item to complete the setting Set each of the parameters required for running the SDC15 25 26 35 36 The following two types of parameters are set e Basic functions Basic functions for device operation such as control and communications functions e Option functions Functions related to optional specifications such as user function DO assignment and extended tuning Chapter 3 SETTING UP B Handling Precautions e is displayed within the cell for parameters whose setting is not required or is prohibited by other setting items These parameters cannot be set In this case re check the type setting or other related settings e Items on the horizontal axis are channel num
8. happens reconnect the loader plug correctly REQUEST Ensure that this User s Manual is handed over to the user before the product is used Copying or duplicating this User s Manual in part or in whole is forbid den The information and specifications in this User s Manual are sub ject to change without notice Considerable effort has been made to ensure that this User s Manual is free from inaccuracies and omissions If you should find any inaccuracies or omissions please contact Yamatake Corporation In no event is Yamatake Corporation liable to anyone for any indirect special or consequential damages as a result of using this product 2005 Yamatake Corporation ALL RIGHTS RESERVED Unpacking Check the following items when removing the SLP C35 from its package 1 Check the model No to make sure that you have received the product that you ordered 2 Check the SLP C35 for any apparent physical damage 3 Check the contents of the package against the Package List to make sure that all accessories are included in the package After unpacking handle the SLP C35 and its accessories taking care to prevent damage or loss of parts If an inconsistency is found or the package contents are not in order immediately contact your dealer SLP C35 System disk SLP C35J50 CD ROM CC a The Role of This Manual A total of eight different manuals are available for the SDC 15 25 26 35 36 Read them as nece
9. screen display 9999 Display low limit Lower value of vertical axis of 1999 to display upper 10 of right axis screen display limit Display high limit Upper value of vertical axis of Display lower limit to 110 of right axis screen display 9999 e Trend monitor individual Setting Item Setting Range Factory Setting Data type Type of sampled data 0 Not used 8 User defined data Axis Specify an axis used for the graph re Left Right User defined Address of relevant parameter Address of communicable address when the data type is set as parameter user type Station adress Set the station address when a 0 to 127 1 CMC10B for example is used Station Set the station sub address 0 to 127 sub adress when a CMC10B for example is used Un Handling Precautions e When the user defined address is specified make the decimal point setting manually 4 7 Chapter 4 MONITORING 4 8 e Digital trend Setting item Setting Range Address of parameter 256 to 32767 Specified bit of parameter O to 15 Name Name of parameter Up to 10 alphanumeric characters e Selecting trend monitor colors Elle Trend Monitor Digital Trend Bo Oci Bo S see Woe ee Bice Bc se Sos Boe Be El See Bee M El ee Bee _ ew UA swe ces Cancel When selecting Graph 1 to Graph 16 the color selection screen will appear Select a desired color Clicking
10. 5 Chapter 4 MONITORING Changing of data Operation by entry of numerical values Enter the numerical value and press the Return key Setting of user defined address Optional data not in the table can be registered to user configuration address UF 1 to 8 in the table Data can be read or written according to the data type e How to set user defined address 1 Select the Set monitor tag under Option O Setup in the pull down menu 2 Enter the address of the data to display according to SDC15 Single Loop Controller User s Manual Installation amp Configurations CP SP 1148E SDC25 26 Single Loop Controller User s Manual Installation amp Configurations CP SP 1149E and SDC35 36 Single Loop Controller User s Manual Installation amp Configurations CP SP 1150E Use of the command line Data can be read or written or the mode switched by directly entering communications commands on the command line Un Handling Precautions e Transmission of the vvrong command may result in trouble on the SDC15 25 26 35 36 For this reason take sufficient care when describing command types addresses data and other information e For details on communications commands and data addresses refer to gt SDC15 Single Loop Controller User s Manual Installation amp Configurations CP SP 1148E SDC25 26 Single Loop Controller User s Manual Installation amp Configurations CP SP 1149E SDC35 36 Single Loop Controller Us
11. Default will return the color setting to its initial value 5 x Color Basic colors BE BEBAOAOI Define Custom Colors gt gt Cancel Chapter 4 MONITORING e Setting up the trend trigger Elle Numeric Monitor Trend Monitor Trend Monitorfindividual Digital Trend Monitor Trend Monitor Color Trend trigger On trigger Off trigger Save trigger O None 25 DM REV e O None 25 DN REV O None 25 DN REV 4 Di 26 DI2 REV C 1 04 C 26 DI2 REV C 1 04 26 DI2 REV 2DI2 C 27 DIB REV 2DI2 C 27 DIB REV C 2DI2 27 DIB REV 3 DI3 C 28 DI4 REV 3 Di3 C 28 DI4 REV C 3 DI3 C 28 DI4 REV C 4 D4 C 29 EV1 REV C 4Dl4 C 29 EV1 REV C 4014 C 29 EV1 REV C SEV1 C 30 EV2 REV C SEVI C 30 EV2 REV C SEV1 30 EV2 REV C BEV2 C 31 EV3 REV C amp EV2 C 31 EV3 REV C amp EV2 C 31 EV3 REV C 7EV3 C 32 DM REV C TEV3 C 321 DM REY C TEV3 C 321 DM REY C 8 D1 33 1 DI2 REV 8 1 DH C 33 1 DI2 REV C 8 D1 33 1 DI2 REV C 9 DI2 34 1 DIS REV C 9 I DI2 C 34 1 DIS REV C 9 1 Di2 34 1 DIS REV 10 1 DI3 C 35 DI4 REV C 10 1 DI3 C 35 1 DI4 REV 10 DI3 C 35 DI4 REV 11 1 D14 36 1 DIS REY C 411 1 Di4 C 36 DIS REV 411 1 DI4 C 36 DIS REV C 121 DI5 C 37 LEV1 REV C 121 DI5 C 37 EV1 REV C 121 DI5 C 37 LEV1 REV 413 E 41 33 EV2 REV CANSEI C 38 EVZ2 REV C 13 l EV1 C 38 EMZ2 REV C 14 EV2 C 39 EV3 REV C 14
12. GP UM S200E istEaiion P ZAMATAKE Yamatake Corporation Advanced Automation Company Totate International Building 2 12 19 Shibuya Shibuya ku Tokyo 150 8316 Japan URL http www yamatake com Printed on recycled paper 04 Specifications are subject to change without notice Printed in Japan 1st Edition Issued in Oct 2005 E
13. WAIL AN PAN No CP UM 5290E SLP C35 Smart Loader Package for SDC15 25 26 35 36 Single Loop Controller User s Manual Thank you for purchasing the SLP C35 for Single Loop Controller SDC 15 25 26 35 36 This manual contains information for ensuring correct use of the SLP C35 It also provides necessary information for installation maintenance and trou bleshooting This manual should be read by those vvho design and maintain devices that use the SDC15 25 26 35 36 Be sure to keep this manual nearby for handy reference Yamatake Corporation RESTRICTIONS ON USE This product has been designed developed and manufactured for general purpose application in machinery and equipment Accordingly when used in applications outlined below special care should be taken to implement a fail safe and or redundant design concept as well as a periodic maintenance program e Safety devices for plant worker protection e Start stop control devices for transportation and material handling machines e Aeronautical aerospace machines e Control devices for nuclear reactors Never use this product in applications where human safety may be put at risk IMPORTANT Do not apply a strong force while connecting a loader plug Failure to do so might damage the instrument uU Handling Precautions Application of excessive force to the loader plug might cause communication failure If such failure
14. ader connect the loader cable e Before starting the trend monitor configure the settings suitable for the trend monitor e The sampling cycle sometimes shifts due to fluctuations in the communications cycle To perform measurement at exact times use the special recorder or data logger 4 1 Chapter 4 MONITORING mM Screen explanations 4 2 Numeric monitor screen ee SLP C35 Monitor Screen Numeric Monitor OFF Trend Monitor OFF File Numeric Monitor M Option O Trend Monitor T Help Basg Numeric Monitor ltem RUN READY AUTO MANUAL LSP RSP Auto Tuning Numeric Monitor Self Tuning ALARM EVENT IHH Proportional Band P Integral time l Derivative timelD Singur low inot l EV TIL I D IHI Motor adj MHI Motor adj AUTO MANUAL Auto Tuning 1 MANUAL O AT Stop LSP RSP O LSP Heater current CT 1 0 0 Heater current CT 2 AT progress UF4 e Menu configuration list File Quit Quits the Monitor window the Monitor window Ctr Numeric Numeric a Starts stops the monitor Ctrl M Monitor M Start Stop M Option eT Setup Displays the Setup window O Command Line C Displays the Command Line window Trend a Changes the display to the trend Monitor T monitor Help Help Version A Displays the version information Chapter 4 MONITORING Tren
15. adsheet application Saving clipboard graph output The display contents on the Trend Monitor screen can be directly saved into the clipboard as a copy of the screen 4 10 Chapter 5 TROUBLESHOOTING 5 1 Error Messages and Remedy mM Communications error messages Communication Time out The message cannot be received Check the cable connections and within a period of the time out time contacts An instrument other than SDC15 25 Use the loader with it connected to 26 35 36 is connected SDC15 25 26 35 36 The main unit is not connected Cannot open communications port The communication port cannot be Do not run the loader and other application using the communication port at the same time Communications error has The system error occurs Re operate or quit the loader to occurred restart Windows Trend monitor is active The monitor screen cannot be quitted Quit the monitor screen after the while the trend monitor is running trend monitor has been completed SDC15 25 26 Cannot support currently The loader currently in use is not Contact Yamatake Corporation or 35 36 connected SDC 15 25 26 35 36 applicable to the version of the main its dealer status error unit Loader Lock or Communication The data cannot be loaded from the Cancel the loader lock or password Lock loader since the loader is locked or to restart the operation the password is set mM File error messages File name This filen
16. ame is not valid An invalid file name is input Input a correct file name error This file cannot be found A file name not existing is input Input an existing file name Make sure that the correct path and filename are given This filename is a reserved A file name reserved for the device Input a correct file name device name name is input Use a different filename Disk error Not enough free space on disk The disk free capacity is insufficient Keep a sufficient disk free capacity The device is not ready The disk is not ready Prepare the disk and restart the operation Cannot make file The CD ROM is specified as save Save the file to another directory destination File name too long The file name is too long Use 256 characters or less for the file name Pass name The path does not exist An illegal path name is input Input a correct path name and error Make sure that the correct path is restart the operation given File information Illegal file size The file is corrupted Corrupted file cannot be used error Illegal file information Create a file again Chapter 5 TROUBLESHOOTING 5 2 Other Troubleshooting Numeric values are not displayed lf a decimal point symbol other than period Check that the decimal point symbol correctly is set the loader does not function correctly is period If not set the decimal point symbol to period Revision History date Oct 2005
17. ations CP SP 1149E SDC35 36 Single Loop Controller User s Manual Installation amp Configurations CP SP 1150E LJ Handling Precautions e When the adjustment function is used adjustment value stored on the controller so far are discarded When this function is used for the first time the controller s default adjustment values are discarded Pay sufficient attention to this when using this function 1 1 Chapter 1 INTRODUCTION 1 2 System Operating Environment The following system environment is required for using the loader mM Hardware Personal Computer Target model PC AT compatibles with a Pentium chip or higher 32M byte or more Operating system Windows98 Me 2000 Professional XP Home XP Proffessional Peripheral Devices Display Serial port It is recommended to use a personal computer with 9 pin serial port built in If your personal computer does not have any serial port you may use any of the extension adaptors listed below to connect the loader cable However note that the operation may become unstable depending on the personal computer environment e Special interface port replicater Adaptor specially designed for each personal computer special adaptor for each personal computer model e CF card adaptor CF232 manufactured by Elan Digital systems URL http www elandigitalsystems com interface cf232 php Operation confirmed personal computer IBM s Thinkpad A31 REX CF60 manufacture by RATOC
18. bers when basic functions are being set up and are event output numbers or external switch input numbers when option functions are being set up e About connection to the personal computer Normally the controller is connected to the personal computer with the special cable Select Option O Environment Setting and set Communication Setup to Connect through CMC10L or Connect through CMC1 0B The controller is then connected through the CMC10B L At this time the environment setting and communication setup on the controller main unit must be adjusted beforehand Additionally configure the settings on the controller in the offline mode the cable is not connected to the controller Note e For details on the functions refer to gt SDC15 Single Loop Controller User s Manual Installation amp Configurations CP SP 1148E SDC25 26 Single Loop Controller User s Manual Installation amp Configurations CP SP 1149E SDC35 36 Single Loop Controller User s Manual Installation amp Configurations CP SP 1150E Step 5 saving setup data When you have finished making the settings save the setup Saving setups in advance and using saved setups greatly reduces the time and load when setting up the loader The following items are saved e Type e Setup parameters 1 The operation is the same by selecting the File Save As or Ctrl A keys gt gt The Save As dialog box appears Save As 2 x Save in
19. chased as the backup system g Handling Precautions E Loader functions Setup function Monitor function Adjustment function e This disk does not contain the system and cannot be used as they are The loader has the following functions e Setup function e Monitor function e Adjustment function e PID simulator function This function is for setting up parameters required for running the controller on the personal computer and writing setting them to the controller For details refer to gt Chapter 3 SETTING UP After the setup parameters have been written to the controller changes to and tuning of control constants while the controller is running switching of modes RUN READY AUTO MANUAL etc run state and alarm occurrence can be checked The run state can also be checked on the Trend screen and sampled data can be output in CSV format so that it can be handled in third party spreadsheet software such as Microsoft Excel For details refer to gt Chapter 4 MONITORING B Handling Precautions e The monitor target is limited to only one unit when the loader jack on the front panel is used for performing monitoring This function is used when the user adjusts controller input For details on the adjustment function refer to gt SDC15 Single Loop Controller User s Manual Installation amp Configurations CP SP 1148E SDC25 26 Single Loop Controller User s Manual Installation amp Configur
20. d monitor screen Tk i File Trend monitor Option Numeric Monitor Help 1 200 1 000 00 00 00 00 00 00 aly 1 PV al 2 MV aM 3 SP OF 4 H M JT 5 C M AT 6 CT1 Se el 8 UF Gi 9 UF el 10 UF el 11 UF ei 12 UF el 13 UF ei 14 UF ST V5 UF ei 16 UF aly OUTI aly OUT2 aV EVI ol EV2 iv EV3 e Menu configuration list Trend Trend pela Starts stops the trend monitor Ctrl T monitor Start Stop I a CSV Read Reads the trend data a CSV Out X Outputs the trend data in CSV format El Clipboard Graph Outputs an image of the graph to Ctrl C Out the Clipboard Displays the Setup window Numeric Changes the display to the Monitor numeric monitor 4 3 Chapter 4 MONITORING 4 4 e con list CE JReturs the graph tothe siari tme A Rems the graph by 12 screen 4 returns the graph by 174 soreen p Advances the graph by 174 screen Pe JAdvances the graph by 12 screen ME Advances the graph tothe latest ime TQ feooms outthe graph a ndoes the graph zoom a Specify a time scale of the graph e Zooming the graph Drag the mouse from the upper left portion to the lower right portion with the left mouse button kept pressed e Canceling the zoomed graph Drag the mouse from the lower right portion to the upper left portion with the left mouse button kept pressed Chapter 4 MONITORING 4 2 Method of Operation mM How to operate the numeric monitor
21. e Corporation All Rights Reserved tip waw yamatake com e Menu configuration list g fee Displays the Setup window Ctrl S Monitor Displays the Monitor Trend Ctrl M window O a a ea foon Changes he environment setup OME Jon famnen oma B veson Displays he version normaron Cra 3 1 Chapter 3 SETTING UP Setup screen Tool bar Menu bar Intitled SLP C 35 C15TROT A00XX Os bee BAB YY we wal gt Selection window gt m 1 1 EE 3 EES EE a ie os Bu El ET 0 El B Pp Message window Parameter display area Chapter 3 SETTING UP e Menu configuration list File fie Creates new data Ctrl N Opens existing data CtrivO mee Saves the active data Ctrl S Save As Saves the active data with Ctrl A name CSV Out X Saves the active data in CSV Ctrl X format HTML Out H Saves the active data in HTML Ctrl H format Print Prints out the data Same contents of data saved in the HTML format 2 Quits the application Ctrl Q Data Check Checks all setting values Ctrl D Q Data Check Bit edit Inputs to bit lists Ctrl B HL Edit Input Output Displays the input output port Ctrl P Port setup setup screen Stores the copy source Ctrl C Pastes the stored copy data Ctrl V aa Parameter disp area Displays the parameter display po area Hint enable Displays the hint a Auto size Makes the auto cell size enabled Size initalize
22. ee es guen ales ee pea ope fai eee ee tee hase cen 1 1 E Loader i dlgie is a ie sos het ce os ee eee AEA 1 1 System Operating Environment 6 000 c cece cece eee eee ees 1 2 cle Clee eee ee eee ee eee ee eee EA were ree Pees rere yee errr 1 2 mM Hardware Contiguration 4 lt cossensarsascectonecreractenderweseeaoerewn 1 3 INSTALLATION STARTING UP AND QUITTING THE LOADER E Installing the loader nce us ses ets ns caren edadat os Cada as d edeeia vasian 2 1 E Starting Up lOGd reiiiaosanss dasemtiessadems sans ehtes maneielaewentedeen 2 5 E Quitting loade sac cp tet et epee ee eit ees epee tenes 2 5 SETTING UP Setup FUNGON ea ninsonsdoteestitoced sssiuesdestea Caps End end tating ta e 3 1 OME ia IT 3 1 E Screen explanations cerecensomas sent secumt ei ies madiai esta tesi duen 3 1 Method of Setup ii aa A 3 4 MONITORING Monitor Function s 06660566566 eee in ede eewe ee eed yews sane eeeesaseeeeeeews 4 1 MOV a Was cs co ors wk es ee eee 4 1 E Screen explanations sivsc6cu ohs 4ccewsi ances dent eie send cosa semecimes 4 2 Method Of Operation lt lt 22 lt lt teeeian cteesne estes neneeseaedadeeseheatedeus 4 5 mM How to operate the numeric monitor screen eee 4 5 m How to operate the trend monitor cece eee ence eee eens 4 7 TROUBLESHOOTING Error Messages and Remedy s cece e cece cence een sauna 5 1 mM Communications error messages ee au ua uv dava eee eee eee tee
23. er s Manual Installation amp Configurations CP SP 1150E e Loader lock is enabled Checking details of alarms You can check the details of alarms in the Alarm window when an alarm occurs e Click icon The operation is the same by selecting the Option O Alarm A e The details of the alarm that is occurring are displayed B Handling Precautions e This window displays the details of currently occurring alarms and does not have a function for restoring the SDC15 25 26 35 36 To restore the SDC15 25 26 35 36 you must perform the appropriate remedy described in Chapter 5 TROUBLESHOOTING 4 6 Chapter 4 MONITORING About the numeric group monitor The numeric group monitor can be used when Connect via CMC10 is set by the Environment Setting Communication Setup Connect the loader cable to CMC 10B L Up to eight groups can be monitored mM How to operate the trend monitor ge Setup Select Trend Trend monitor individual and Digital trend at Option O Setup and make the following settings for each sampled data 1 to 16 As the cycle and display upper lower limits are common to all channels e Trend Setting Item Setting Range Setting Setting of sampling cycle 1 to 3600s Display low limit Lower value of vertical axis of 1999 to display upper of left axis screen display limit Display high limit Upper value of vertical axis of Display lower limit to 1200 of left axis
24. even if the type is changed on the loader e For an explanation of each of the specifications refer to gt SDC15 Single Loop Controller User s Manual Installation amp Configurations CP SP 1148E SDC25 26 Single Loop Controller User s Manual Installation amp Configurations CP SP 1149E SDC35 36 Single Loop Controller User s Manual Installation amp Configurations CP SP 1150E Step 2 initialization 1 Click L icon The operation is the same by selecting the File New or the Ctrl N keys gt gt The initialize dialog box appears x 4 1 Information G Initialize Data Cancel 2 Click OK button gt gt A new file opens 3 5 Chapter 3 SETTING UP Step 3 setting up the environment Set the communications port and font on the personal computer 1 Click I icon The operation is the same by selecting the Option Environment Setting or Ctrl E keys gt gt The Environment Setting dialog box appears Environment Setting Communication Port Communication Setup Font size OPort COM OPort CON3 uUse Loader Cable O7 OPort COH2 O Port CON10 Ouse CMC10L Si O Port COM3 OPort COM11 Ouse CMC10B O Port COM4 OPort COM12 Station address Station sub address O a OPort CONS O Port COM13 On OPort COMB OPort COM14 Ge O OPort COM O Port COM15 11 OPort Cons Port COM16 Eal On Transmission speed Data Length Parity Stop bits Fixed Cell Width 2 Set the
25. hen the setup is completed start up the trend monitor Click icon The same operation can be started by selecting Trend Monitor Trend Monitor Start The data sampling is started and then the trend of the specified parameters is displayed on the screen e Once the trend monitor is started it continues until the stop operation is performed or the data for 60 000 cycles is sampled e If the stop operation is not performed the data is overwritten onto the old data when the data sampling for 60 000 cycles is completed e The screen can be transited to the Numeric Monitor screen while the trend monitor is running However the loader cannot be quitted or the screen cannot be transited to the Setup screen To do so quit the trend monitor Stopping the data sampling Select Trend Monitor Trend Monitor Stop The trend monitor is then stopped Chapter 4 MONITORING Saving sampled data The data sampled using the trend monitor can be saved into a file in the CSV format The sampled data saved in the CSV format can be processed using spreadsheet applications such as Microsoft Excel n Handling Precautions e The data can be saved into a file even while the trend monitor is running e The data which has been saved into a file is retained in the personal computer unless it is initialized However the data saved in the file cannot be redisplayed on the loader screen To display such data use an appropriate spre
26. le program F BASIC POF file japanese IV PDF filetenglish DO Help file japanese M Help filetenglish Note e Check on necessary files To display a PDF file it is absolutely necessary to install Acrobat Reader For details refer to gt Note on page 2 5 141k 6k 13105k 3859 k 17830 k 9985 k 2 3 Chapter 2 INSTALLATION STARTING UP AND QUITTING THE LOADER 7 Check on put a check mark hr software components you wish to install and click Next gt button gt gt The following screen appears v Select Start Menu Group Accessories Administrative Tools IrfanView Note e To change the program folder enter the new folder name 8 Click Next gt button gt gt The following screen appears Start Installation 9 Click Next gt button gt gt The following screen appears Installation Complete 2 4 Note E Starting up loader mM Quitting loader Chapter 2 INSTALLATION STARTING UP AND QUITTING THE LOADER 10 Click Finish gt button gt gt When the installation is completed successfully the screen will return to the Windows screen e Installation of Adobe Acrobat Reader If the Adobe Acrobat Reader is not installed in your personal computer install it using any of the following procedures e Download the Adobe Acrobat Reader from Adobe Systems home page e Install adberdr60_enu_full exe from the CD ROM
27. m using the communication functions of this unit must thoroughly read this manual This manual also describes the installation wiring connections for communication all functions and settings of this unit operating procedures communication with host station such as personal computer communication addresses troubleshooting and detailed specifications SLP C35 Smart Loader Package for SDC15 25 26 35 36 Single Loop Controller User s Manual Manual No CP UM 5290E This manual This manual is supplied with the SLP C35 Smart Loader Package The manual describes the software used to make various settings for SDC15 25 26 35 36 using a personal computer Personnel in charge of design or setting of a system using SDC15 25 26 35 36 must thoroughly read this manual The manual describes installation of the software into a personal computer operation of the personal computer various functions and setup procedures il SDC25 26 Single Loop Controller User s Manual Installation Manual No CP UM 5288E This manual is supplied with the product Personnel in charge of design and or manufacture of a system using this unit must thoroughly read this manual This manual describes the safety precautions installation wiring list of parameters and primary specifications For further information about operation refer to another manual Installation amp Configurations SDC25 26 Single Loop Controller User s Manual Installation amp Configu
28. ns 5 1 Mm File error Messages se ceiisia sisena vi densdeensteeetienseebessuaretanien 5 1 Oiher Troubleshooting 142063 5000cse peer erorany eretti m airnn grees 5 2 Conventions Used in This Manual The follovving conventions are used in this manual 1 Handling Precautions EB Note i gt 1 2 3 OK button Option gt gt Ctrl key A key Ctrl A key Handling Precautions indicate items that the user should pay attention to when handling the SLP C35PRO Notes indicate useful information that the user might benefit by knowing This indicates the item or page that the user is requested to refer to The numbers with the parenthesis indicate steps in a Sequence or indicate corresponding parts in an explanation Indicates a selection button in screens displayed on the personal computer Indicates messages and menus displayed on the personal computer Indicates the result of an operation details displayed on the personal computer or devices or the state of a device after an operation Indicates keys on the keyboard Indicates the operation of pressing the A key with the Ctrl key on the keyboard held down vi Chapter 1 INTRODUCTION 1 1 Overview This software SLP C35 is an engineering tool for the SDC 15 25 26 35 36 Note e Install SLP C35 on the hard disk following the procedure in CFH Installing the loader page 2 1 Use the system disk that you have pur
29. of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law If the SLP C35 having the old version has been installed the screen shown below appears Click the OK button to uninstall the SLP C35 having the old version Delete old version SLP C35PRO 5DC35 3 E3 Delete old version SLF C3 SPROGDCS 5 36 Cancel Chapter 2 INSTALLATION STARTING UP AND QUITTING THE LOADER 2 Click Next gt button gt gt The following screen appears S3 SOFTWARE LICENSE AGREEMENT 3 If you agree to the software license agreement and wish to install the loader click the Agree gt button If you abort the installation click the Don t agree button gt gt When clicking the Agree gt button the following screen appears J3 Get Registration Information 4 Enter a registered user name and company name and then click the Next gt button gt gt The following screen appears 3 Display Registration Information 2 2 Chapter 2 INSTALLATION STARTING UP AND QUITTING THE LOADER 5 Click Next gt button gt gt The following screen appears E Choose Destination Location Note e To change the installation destination directory click Browse button 6 Click Next gt button gt gt The following screen appears E Select Components M sample program C Builder M samp
30. ous running parameters parameters can be changed e Lamp indication of the various running modes lamp indications can be operated e Alarm display representative and detailed Trend Monitor screen This screen is for monitoring the running state of the SDC 15 25 26 35 36 in the form of a trend graph e Screen display of trends for max of sixteen data items e Screen display of digital data trends for max of five data items e Export of sampled data as CSV file e Trend screen dumps e Data type PV SP MV user defined data all analog data that can be communicated e Sampling cycle Variable within the range 1 to 3600s e Max sampling count 60 000 fixed regardless of number of data items to sample Note eA CSV file is the data format that can be handled in third party spreadsheet software such as Microsoft Excel In this format sampled trend data can be interpreted in spreadsheet software These screens can be used to perform the following operations e Monitoring of the running state and changing of parameters in the Numeric Monitor screen e Switching of the run mode in the Numeric Monitor screen e Tuning of control constants in the Numeric Monitor screen e Monitoring of trends and sampling of data while the SDC 15 25 26 35 36 is running e Monitoring of alarm states in the Numeric Monitor screen g Handling Precautions e About connection to the personal computer When making the setup or operating the monitor using the lo
31. rations Manual No CP SP 1149E This manual is optional sold separately The manual describes the hardware and all functions of this unit Personnel in charge of design manufacture operation and or maintenance of a system using this unit and those in charge of communication software of a system using the communication functions of this unit must thoroughly read this manual This manual also describes the installation wiring connections for communication all functions and settings of this unit operating procedures communication with host station such as personal computer communication addresses troubleshooting and detailed specifications SDC35 36 Single Loop Controller User s Manual Installation Manual No CP UM 5289E This manual is supplied with the product Personnel in charge of design and or manufacture of a system using this unit must thoroughly read this manual This manual describes the safety precautions installation wiring list of parameters and primary specifications For further information about operation refer to another manual Installation amp Configurations SDC35 36 Single Loop Controller User s Manual Installation amp Configurations Manual No CP SP 1150E This manual is optional sold separately The manual describes the hardware and all functions of this unit Personnel in charge of design manufacture operation and or maintenance of a system using this unit and those in charge of communication
32. screen Start of monitoring start of communications The operation described below is required to start monitoring Otherwise monitoring and rewriting of data cannot be performed e Click icon The operation is the same by selecting Numeric Monitor Numeric Monitor Start gt gt During normal operation The data on the SDC15 25 26 35 36 is displayed During an error The message Check the device to which the loader is connected is displayed Remedy according to Chapter 5 TROUBLESHOOTING The following operations are possible when the device and the loader are correctly connected Monitoring of run state and changing of parameters Numeric monitor Tag name displayed in table format Process Variable PV Numeric group monitor Set point SP Manipulated variable MV State monitor RUN READY mode displayed in lamp lighting AUTO MANUAL mode format LOACAL REMOTE state Auto tuning start stop state Self tuning start stop state ALARM mode Control output ON OFF state Event output ON OFF state Internal event ON OFF state DI terminal ON OFF state Operation SP value change Operations possible in SP set change numeric changes are Manipulated variable MV change in MANUAL mode limited as follows PID value change RUN lt READY switching AUTO lt MANUAL switching Auto tuning start lt gt stop switching About the operation mode RUN READY mode 0 RUN 1 READY AUTO MANUAL mode 0 AUTO 1 MANUAL 4
33. software of a system using the communication functions of this unit must thoroughly read this manual This manual also describes the installation wiring connections for communication all functions and settings of this unit operating procedures communication with host station such as personal computer communication addresses troubleshooting and detailed specifications i Organization of This User s Manual This manual is organized as follows Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 INTRODUCTION Be sure to read this chapter before you start using the Smart Loader Package This chapter describes the required operating environment for the personal computer how to install the package and briefly introduces its features INSTALLATION STARTINGUP AND QUITTING THE LOADER This chapter describes how to install start up and quit SETTING UP This chapter describes how to set up the data MONITORING This chapter describes how to change the settings as well as the screens monitoring the operation status TROUBLESHOOTING This chapter describes error messages that are displayed when trouble occurs and how to remedy trouble 1V Contents Unpacking The Role of This Manual Organization of This User s Manual Conventions Used in This Manual Chapter 1 1 1 1 2 Chapter 2 Chapter 3 3 1 3 2 Chapter 4 4 1 Chapter 5 5 1 5 2 INTRODUCTION OV OVO as a arena
34. ssary for your spe cific requirements If a manual you require is not available contact Yamatake Corporation or its dealer SDC15 Single Loop Controller User s Manual Installation Manual No CP UM 5287E This manual is supplied with the product Personnel in charge of design and or manufacture of a system using this unit must thoroughly read this manual This manual describes the safety precautions installation wiring list of parameters and primary specifications For further information about operation refer to other manuals Basic Operation and or Installation amp Configurations SDC15 Single Loop Controller User s Manual Basic Operation Manual No CP SP 1147E This manual is optional sold separately The manual describes the functions you can set up only with Simple configuration Personnel in charge of design manufacture operation and or maintenance of a system using this unit must thoroughly read this manual This manual describes the installation wiring major functions and settings operating procedures troubleshooting and detailed specifications SDC15 Single Loop Controller User s Manual Installation amp Configurations Manual No CP SP 1148E This manual is optional sold separately The manual describes the hardware and all functions of this unit Personnel in charge of design manufacture operation and or maintenance of a system using this unit and those in charge of communication software of a syste
35. t device Note e Personal computer used for confirmation of operating environment Dell OptiPlex GX110 Think Pad A31 1 3 Chapter 2 INSTALLATION STARTING UP AND QUITTING THE LOADER mM Installing the loader This section describes how to install the loader on a personal computer o Handling Precautions e If you start up the Installer while another application is running the Installer may malfunction Remove other resident applications from their directories before starting up the Installer The SLP C35 sometimes cannot be started up depending on the combination of other applications and drivers For details on Windows and personal computer settings refer to the User s Manuals provided with Windows and the personal computer Installing loader 1 Set the CD ROM in the CD ROM drive of your personal computer gt gt The installation program is then started up automatically and the following screen appears Ja Welcome Welcome to SLP C3 SPROGDC3 5 36 Setup program This program will install SLP C3 SPROGDC3 5 36 on your computer lt is strongly recommended that you exit all Windows programs before running this Setup Program Click Cancel to quit Setup and close any programs you have running Click Next to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion
Download Pdf Manuals
Related Search
Related Contents
ASUS F1A75-M User's Manual LG 26 40-UA Specification Sheet AutoRep™ E Repeating Dispenser Operating Manual ABREGE DE DEPANNAGE ADMINISTRATIF_logo Suiveur d`impulsions opto-couplées Carte dans le Loiret - Fédération Régionale des Chasseurs du Centre VWHD-4260 User manual - Diffusion Service Medcare`s P440/600 Owner`s Manual Graco 312484C User's Manual Copyright © All rights reserved.
Failed to retrieve file