        SuperMAX Electrometer-Temperature Correction
         Contents
1.    A  STANDARDIMAGING    TECHNICAL NOTE   page 1of2    DATE MARKETS  10 05 15  PAGE          NUMBER  4811 00                   SUBJECT  SuperMAX Electrometer     Temperature Correction          The following information is provided as a service to our users and customers        The SuperMAX electrometer is an advanced  two channel electrometer used for  measurements in ionizing radiation environments  It is well known that the  components of electronic instruments can be sensitive to temperature change  and the SuperMAX electrometer is no exception  In house measurements have  shown that the internal temperature of the SuperMAX takes about 2 hours to  equilibrate after starting from room temperature in an unpowered state  This  results in the interior being approximately 6   C above the ambient room  temperature  If not corrected for  this temperature change can affect  measurements  especially in the low range  Since it is not desirable for users to  allow 2 hours of warm up  a temperature correction algorithm was implemented  in the SuperMAX  This algorithm corrects for the zero drift that occurs as the  temperature changes in the enclosure and allows the device to function  acceptably with essentially zero warm up time     The required temperature correction can shift as the unit ages which may cause  zero drift  or charge collection measurements that trend up or down as the  SuperMax warms up  This is not of consequence for most users if the amount of  drift is small comp
2. ared with the measurement signal level  Additionally  the user  can simply re zero as needed  as described in the user manual  However  it may  be a concern for users performing low level measurements  such as with the  Exradin W1     If desired  a SuperMax returned to Standard Imaging for recalibration or service  can be re profiled for the temperature correction at no charge  This process  automatically recalculates the temperature correction coefficients for both ranges  and then verifies it is working properly     If zero drift or measurement deviation is suspected  please perform the following  troubleshooting steps     1  Make sure the SuperMAX has been unplugged and allowed to cool to  room temperature for at least 4 hours    2  Plug in the SuperMAX and turn on the display    3  Switch to dual channel mode and put both channels in low range    4  Zero the SuperMAX with nothing connected to the Triaxial inputs and the  dust caps in place     3120 Deming Way    Middleton  WI 53562 2532 e WEB  standardimaging com  Tel  608  831 0025 e  800  261 4446 e Fax  608  831 2202                DATE MARKETS  10 05 15  PAGE    2  STANDARDIMAGING    TECHNICAL NOTE   page 2 of 2          NUMBER  4811 00                   SUBJECT  SuperMAX Electrometer     Temperature Correction          5  If the rate reading is more than     10 fA on either channel over the course  of 2 hours  you may send your SuperMax back to SI to re profile the  temperature correction  A return authorization can 
3. be requested at    support standardimaging com  6  If checking the high range  the rate reading threshold is     5 pA     Note that the display is the primary source of heat inside the enclosure  so simply  leaving the SuperMax plugged in with the display off is not a complete  workaround     3120 Deming Way    Middleton  WI 53562 2532 e WEB  standardimaging com  Tel  608  831 0025  800  261 4446 e Fax  608  831 2202             
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
水やりタイマー 取扱説明書  Supermicro SuperChassis 732G-500B  UM10391 - NXP Semiconductors  取扱説明書 [F-03B] - Altehandys.de  ETA Systems eta-ecm2063 User's Manual    1036 - Manutan  Omron HBP-1300 User's Manual  CASDAR Flexi-sécurité - Chambre d`agriculture de la Manche  ASUS ARB7510 User's Manual    Copyright © All rights reserved. 
   Failed to retrieve file