Home

C.A. Unicenter Integration

image

Contents

1. cee eeeeeee eect ee eeeeeeeeeeeeaeeeeeeaaeeeeeaaeeeseaaeeesaaeeeseeaaeeeseeaaeeeeseaaeeeeseaeeeeseaaes 4 A US6i 028 ancien cect a edt nadie le Geet peed Ged dv eel De 5 4 1 EATON Automatic discovery AUtO DiSCOVETY cccccceceeeeeeneeeeeeeeceaeeeeaaeeeeneeseaeeeeaeeseaaeeeeeees 5 4 2 Receive and view UPS alarms 0 ccccccceeececeeeeeeeeeceeeeeeaeeesaaeseeaeeceeeeecaaeeseaaeseeeeeseaeeesaeeseeeeeaes 7 4 3 Launching UPS properties from Unicenter cccccceceeeceeeeeeeeeeeceeeeecaeeeeaaeseeeeeseeeeseaeeneeeenaes 8 4 4 EATON equipment and Unicenter compatibility list 0 ccceceeeeeeeeeceeeeeeeeeeeeeeeeeeeeeaeeneeeeeaes 9 Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 2 9 www eaton com 1 Introduction This document describes the stages to integrate and use an EATON UPS with the Computer Associates Unicenter Network and Systems Management platform This document is applicable for Unicenter version 3 0 To use any EATON UPS with this platform you must have completed the installation and configuration procedures first 2 Installation and configuration procedure 2 1 Installation procedure 1 Execute the ca_unicenter_integration_vxx exe InstallShield package The following actions will be automatically performed e Copy both MIB and Icon files Compile and load the MIB Install the UPS class you have to select the appropriate repository Load Message
2. 4 Use 4 1 UPS Automatic discovery Auto Discovery Any EATON Pulsar UPS with a compatible SNMP card or SNMP proxy agent is automatically discovered by Unicenter Each detected UPS is identified by its IP address Several maps are available e Unicenter Explorer Topology or Unicenter 2 D map View any equipment from a network segment e Unicenter Explorer Class specification View all the UPS detected on the network Unicenter Explorer Root E Worldview DELLCOM E e ManagedObjectRoot 4 Domain SR TCP IP Network BR 172 16 T e o 5 1 i 2 8 Aaah i a KALIF eR 17217 a WBEM Network segment map containing a UPS Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 5 9 www eaton com tE Unicenter Explorer Root a Nemore banks 3 alarmset_name a MobileDevice 172 16 1 247 a UPS 0 GAR Network Bwplore z Node Viewers gt S P i View Performance Gathering Performance Modify Performance Gathering Printers Object View 2 Probe Processor Eng Onpa E Router Telnet SAN SANAppliance i E Scsi_Port UI roperties B Segment Post Unpost toggle G StorageSubsystem Subnet Acknowledge toggle Switch Admin Status to Managed TapeSubsystem Admin Status to Unmanaged Unclassified_Class Unicenter
3. 3 6 1 4 1 705 1 2 2 1 5 X Manager description Unicenter for example 1 3 6 1 4 1 705 1 2 2 1 6 X Manager IP address YYY YYY YYY YYY format 1 3 6 1 4 1 705 1 2 2 1 7 X Community name public for example 1 3 6 1 4 1 705 1 2 2 1 8 X Severity level 2 for example 1 3 6 1 4 1 705 1 2 2 1 9 X Acknoledgement type 2 mgnoack 3 Uninstalling the agent From the Add Remove programs item of the control panel execute Unicenter UPS Device Integration Package This script will perform the following actions e Stop services Unload the MIB Remove both icon and MIB files Remove the class and objects from World View CORE select the appropriate repository Remove the Event Message records and actions Restore Unicenter configuration files nodes dat ip atp and gwclass dat Reset the Unicenter DSM after user confirmation This operation takes several minutes because all Unicenter services need to be restarted This step is necessary to terminate uninstallation Important Notes During restoration of the Unicenter configuration files a backup copy of the current files will be made in their respective directories with the xxx eaton extension It is recommended to compare each configuration file with its copy and merge modifications after uninstallation Restoring a file from its saved copy could erase modifications Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 4 9 www eaton com
4. Management for Events and Actions Modify Unicenter configuration files nodes dat ip atp and gwclass dat Original files will be saved with xxx yyy eaton extension e Reset the Unicenter DSM after user confirmation This operation takes several minutes because all Unicenter services need to be restarted This step is necessary to finalize the package integration 2 Configure Unicenter security for managing events and actions described in the following section 2 2 3 Configure SNMP cards agents described in the following section 2 3 4 Perform auto discovery to detect UPS SNMP cards agents 5 Start the Unicenter Explorer and the Event Management console to detect UPS status changes 2 2 Configure Unicenter security To manage the UPS icon status a few commands must be executed from the EM console with the relevant administration rights EM default settings only authorize the caunint user to perform commands Follow the instructions below to enable the proper settings 1 From the command line DOS execute caugui settings 2 Click on the Event management major tab and then on the Client Preferences minor tab 3 Change the Users authorized to issue commands field to 4 Save the settings 5 From the command line DOS run unicntrl stop opr then unicnitrl start opr Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 3 9 www eaton com 2 3 Configure SNMP ca
5. 6103 Network Management Proxy HTTP OK Na NOK Proxy XML gent Windows Transverse card Card SNMP HTTP OK OK OK SNMP Web 66074 Minislot card Card SNMP HTTP OK OK OK SNMP Web 66244 XML Web card 66073 Card HTTP OK Na OK SP WAN UM Agent Proxy SNMP OK OK na SNMP card 66245 Card SNMP OK OK na SNMP card 66062 Card SNMP OK OK na Unsupported option With Network Management Proxy XML Agent the address http lt IP Address proxy gt eaton default htm giving access to the UPS property page cannot be configured automatically with Unicenter Not recognised as EATON UPS equipment Must be added manually Select your equipment in the console and click on Reclassify Select the UPS class under UPS class Modify the pollset_name properties of the snmp class change host to UPS From the Unicenter 2D Map select the UPS Icon and through right click select Viewer then Class Editor na not applicable Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 9 9
6. ID UNRESOLVED DELLCOM caunint CATD_ _O60 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 18 06 36 35 UNRESOLVED DELLCOMcaunint 172 16 1 247 UNRESOLVED Received trap UPS utility power restored 06 30 03 16 24 UNRESOLVED DELLCOM caunint dint min Setstat A DELLCOM C MGE_UPS N 172 16 1 247 Normal UNRESOLVED DELLCOM caunint CATD_ _O60 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 12 06 36 36 0 DID 16 24 50 UNRESOLVED DELLCOM caunint 172 16 1 247 UNRESOLVED Received trap UPS returned from Battery 06 30 03 16 24 FA 16 24 50 UNRESOLVED DELLCOM caunint dint min Setstat A DELLCOM C MGE_UPS N 172 16 1 247 Normal Recank 54 7 selected Helt O 0 selected OEF BEN BUT FEDER EM Console view Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 7 9 www eaton com UPS Alarm list Severity Alarm message Warning UPS on Battery UPS utility power failed Critical UPS communication failed UPS Battery entering Fault status UPS battery need to be replaced UPS battery reached low condition UPS battery is unavailable UPS has overload condition 4 3 Launching UPS properties from Unicenter For each UPS in all Unicenter views you are able to access a certain amount of information depending on the type of equipment you have For cards with an on board web server you are able to access the UPS properties Web Page S
7. _OpenVMS Delete with Children Unicenter_OpenVMSMa Reclassity UnicenterManagedObje UnicenterManager Ta Copy Unispace Wi eacte spa Delete H TIR aoe Remove fram Parent WBEM E Workstation Eh Method 4 Popup_Menu ty Reference E E Repository_Information 4g TND_Geamap Lg ToolBox OEE aaa Bae 4 nap A t start EMS AM Mcon BE Sen Ame Gunic Bric Eprop Wree izm Bots 1615 View the EATON UPS equipment detected on the network MGE_UPS Class Note MGE_UPS belong to the UPS Class With Unicenter 2 D map each UPS is associated with a specific icon for easy network identification Unicenter Map DELLCOM 05 x File Modes Edit Map Report View Display Window Utilities Help Object View UPS Properties Create Class BPY Create Object Delete Object Ping Object Telnet Post Unpost Acknowledge Admin Status to Managed Admin Status to Unmanaged i 11 7216 1 243 Reclassify Object View Performance Gathering 172 16 1 0 Segment 1 Modify Performance Gathering Network Alarms Ready Run Mode UPS through Unicenter 2 D map view Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 6 9 www eaton com 4 2 Receive and view UPS alarms The icon is associated with the UPS status depending on the alarms received UPS Status Unicenter 2 D map Unicenter Explorer Normal O Warning TN a C
8. elect your UPS and UPS Properties item with one click E T N Powering Business Worldwide UPS UPS Properties gt UPS Control Weekly Schedule Shutdown Parameters Logs and Notification Measurements gt Event Log System Log Email Notification Settings gt Network System gt Notified Applications Access Control gt Time gt Firmware Upload Environment Status 3 Settings Log Network Management Card UPS Properties Help Pulsar M 2200 AC Cutpat Q eee i Voltage 21v Carte 16 Mo 7 1 Current 02A Frequency 50 0 Hz Load leve 0 Apparent Power 0 0 KVA Active Power 0 0 kw UPS Status z Power source AC Power Output load level EE o master On Output Group1 On Group2 On Battery Battery load level A 100 Charging Remaining backup time Sh02mn43s Battery status OK Last update 2008 10 08 11 25 28 Running the UPS properties from Unicenter Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 8 9 www eaton com 4 4 EATON equipment and Unicenter compatibility list EATON equipment Card Protocol Auto Receiving Accessing UPS designation proxy discovery alarms properties Traps using a browser HTTP Network Management Card SNMP HTTP OK OK OK card Minislot SNMP Web 66102 Industrial Network Card SNMP HTTP OK OK OK Management card Minislot SNMP Web 6
9. rds agents Each SNMP card or agent must be configured so that the SNMP alarms Traps are sent to the Unicenter platform To do this the Unicenter host must be declared in the managers table of each SNMP card and agent For this configuration you can use the cards web interface For legacy cards 66074 run the Set SNMP Manager bat script file in lt Unicenter home path gt bin directory and follow the instructions During the procedure you will be asked for e The IP address of your SNMP card or agent e The IP address of the Unicenter host e The read write community name for the agent by default public if not specified e The trap receiver community name by default public if not specified Repeat these steps for each SNMP card or agent NOTE You also have other possibilities 1 For SNMP cards you can use telnet configuration menu You can also use the HTML settings page for the Manager Table settings 2 Usea MIB browser to configure the SNMP cards and agents However we strongly suggest using the script file as these operations require an in depth knowledge of the SNMP protocol and also a good understanding of our products Configuration example for manager number X OID number Designation Value 1 3 6 1 4 1 705 1 2 2 1 1 X Manager number X 1 3 6 1 4 1 705 1 2 2 1 2 X Device number 0 1 3 6 1 4 1 705 1 2 2 1 3 X Manager type 9 other 1 3 6 1 4 1 705 1 2 2 1 4 X Protocol level 4 snmpv1 1
10. ritical Tay fi Using EM Console you can view the traps received from any equipment A text message is associated with each trap alarm or acknowledgement sent by a UPS The color depends on the alarm severity e Green Normal status Alarm Acknowledged e Orange Warning e Red Critical EM Console dellcom Console Message View Options Help Log Messages 06 30 2003 DERE Time Node User Staton Message EEEE 419 UNRESOLVED DELLCOM caunint ZCATD__060 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 17 06 36 05 16 24 19 UNRESOLVED DELLCOM caunint 172 16 1 247 UNRESOLVED Received trap UPS utility power failed 06 30 03 16 24 be Hess UNRESOLVED DELLCOM caunint dint min Setstat A DELLCOM C MGE_UPS N 172 16 1 247 Warming 16 24 20 UNRESOLVED DELLCOMcaunint CATD_I_O60 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 11 06 36 06 0 OID 16 24 20 UNRESOLVED DELLCOMScaunint 172 16 1 247 UNRESOLVED Received trap UPS on Battery 06 30 03 16 24 UNRESOLVED DELLCOM caunint dint min Setstat A DELLCOM C MGE_UPS N 172 16 1 247 Warming UNRESOLVED DELLCOM caunint CATD_ _O60 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 29 06 36 06 0 OID UNRESOLVED DELLCOM caunint CATD_ _O60 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 29 06 36 06 0 OID UNRESOLVED DELLCOM caunint CATD_I_O60 SNMPTRAP c public 705 172 16 1 247 UNRESOLVED 6 29 06 36 06 0 O
11. www eaton com Unicenter Map DELLCOM File Modes Edit Map Report View Display Window Utilities Help Bella E ela LIS Halal he 172 16 1 0 Segment 1 2 a 172 Open Details Poi 2 utra5 aix C A Unicenter Integration User s Manual lol x FALBALA HINKPAD JUAN EERVER TEST 0 24 6 1152 72161153 fi 72 16 1154 Edit Class Create Class BPY Create Object Delete Object Ping Object Telnet Post Unpost Acknowledge Admin Status to Managed Admin Status to Unmanaged a Per 72 16 1243 Reclassify Object View Performance Gathering Modify Performance Gathering 172 16 1 0 Segment 1 Network Alarms Ready Computer Associates Run Mode ale Powering Business Worldwide Computer Associates Unicenter Integration User s Guide 34 003 757 XU AF Page 1 9 www eaton com Table of Contents At Mirade ne eet seat ah Ute eae ate Mia oa hl es eerie domes Gente 3 2 Installation and Configuration ProCeCure eeeceeceeeeeeeeeeeeeeeeeeeeeaeeeeeeaaeeeeeeaaeeeseeaaeeeeeeaeeeeeenaeeeeeeaaes 3 2 1 Installation ProGeGure Snes a A AA A AIA han ivi 3 2 2 Configure Unicenter security cccccceceeeceeeeeceeeeeeeeeeeceaeeesaaeseeneeceaeeesaaeeeeaaeseneeseaeeseaesneaeeeeaes 3 2 3 Configure EATON SNMP Cards agents cc ccescceeceeeeeeeeeeaeeeeneeceeeeseaeeesaaeseeeeeseaeeesaeeneaeeseaes 4 3 Uninstalling the agent

Download Pdf Manuals