Installation and Setting-Up Instructions
Contents
1. Hi HE Turn the installation tool level until the transmitter is fully inserted into the process A I 0 0 08 h ZA _ MISTY 2 6 Fasten the transmitter in place with the locking nut E Tightening torque 40Nm Z 2 A E NL ly i Remove the installtion tool 8 To remove the transmitter from the process reverse the steps shows for inserting the transmitter Figure 1 2b Mounting the transmitter on the coupling SATRON VC Optical Consistency Transmitter Dimensions Satron VCT E ae lin EL E Dimensions Satron VCF Standard 5 m Optional 10 m oatron VC with L housing BCs220AV Revision 1 15 3 2014 SATRON VC Optical Consistency Transmitter 1 2 Electrical connections Supply voltage and load of the transmitter according to the Figure 1 10 We recommend shielded twisted pair cable as signal cable The signal cable should not be installed near high voltage cables large motors or frequency converters The shield of the cable is grounded at the power supply end or according to the recommendations of the manufacturer of the used control system Load 2 Operating region id 15 20 2h 30 35 40 Supply voltage V Min load using HART communication 250 Q Supply voltage 5 V max max 20 5 mA using HART communication max 23 mA when the alam current 22 5 mA is on Figure 1 10 Su
2. 2 op 4 2 mA Suppl ter loop 2 LJ waup Ex Veup Figure 2 3 Remote Connections Figure2 4 VC Sensing connections Inside the Sensing element is a dipswitch and a USB port This is only used for updating the firmware DO NOT USE THE USB PORT UNLESS THERE NEEDS TO BE A NEW FIRMWARE INSTALLED SATRON VC Optical Consistency Transmitter 3 USER GUIDE FOR MENUS The user interface for the series VO analyzers housing option N consists of display and operating keys Among other things the user interface allows you to set process variables in the desired units on the display and to configure the analyzer e g by setting the lower and upper range values In addition you can perform diagnostic routines and view de vice information through the user interface pje ron instruments HAV RNEE 1 Ese J A V Enter The 8 character liquid crystal display LCD with backlight allows you to display information with letters and num bers OPERATING KEYS With the UP DOWN arrow keys and the ENTER and ESC you can move in the menus ENTER Press ENTER to move to a lower level in a menu or to accept a command or parameter value UP Use the UP arrow key to move up on the current menu level to increase the selected parameter value DOWN Use the DOWN arrow key to move down on the current menu level or to decrease the selected parameter value ESC
3. BCs220AV Installation and Setting Up Instructions Contents 1 INSTALLATION 1 1 Mounting location 2 1 2 Installing the transmitter 9 1 3 Dimensions of the transmitter 5 1 4 Electrical connections s 6 2 SETTING UP 2 1 Setting up with Satron VoAdvisor Service Software s 8 2 2 Setting up with local switches 8 23 Setting up with remote unit s 9 3 USER GUIDE FOR MENUS 3 1 Configuration s 10 3 2 New sample s 12 3 3 X Calibration s 12 3 4 Diagnostics s 13 4 SETTINGS 4 1 Basic settings 15 4 2 Collect sample 4 3 Laboratory values 44 Start Up calibration 4 5 1 point calibration 4 6 2 point calibration 4 Offset adjustment 4 8 adjustment 4 9 Time and Date settings O We reserve the right for technical modifications without prior notice DOCUMENTS HARTO is the registered trademark of Hart Communication Foundation Technical Specifications BCs220 Hastelloy is the registered trademark of Haynes International f Teflon E I is the registered trademark du Pont de Nemours amp Installation and Setting Up Instructions BCs220AV Viton is the registered trademark DuPont Down Elastomer 5 SATRON instruments Satron Instruments Inc P O Box 22 33901 Tampere Finland Tel 358 207 464 800 Telefax 358 207 464 801 www satron com info satron com 1 INSTALLATION 1 1 Mounting location Installation recommendations Figure 1 1 transmitters should be
4. c d m A cir he i Program State Program settings User Info i dating 7 Windows 38 MT 2000 P VISTA wersion 100 Date 2009 06 12 Start Window Figure 2 1 VOadviser software 2 2 Setting up with local switches The additional instruction of display menus is enclosed to this manual See chapter 4 ERROR instruments Housing with display code N Keyboard Esc Press Esc move back towards the top of the main menu A Use the UP arrow key to move up on the current menu level or to increase the selected parameter value Y Usethe DOWN arrow key to move down on the current menu level or to decrease the selected parameter value Enter Press ENTER to move to a lower level in a menu or to accept a command or parameter valu Figure 2 2 VC transmitter with display 8 BCs220AV 2 3 Setting up with remote unit The Satron VC transmitter remote unit can be provided with a wall box which is capable of having a 20m cable between the Sensing unit and the Display unit Inside the Display unit is a terminal where up to 3 binary inputs 3 relay outputs and 2 analog milliamp loops can be connected All connections can be used simultaneously The signal cable between the Display unit and Sensing unit should not be installed near high voltage cables large motors or frequency converters Selection window for WO functions remote dis play LI YVO remote transmitter Automation system
5. kl go rm CJ 49 r3 cJ E ES Ln BCs220AV Revision 1 15 3 2014 Insert the GAIN value with the Y and ENTER buttons until up per separator reaches the right end of display Press the ENTER button to store the GAIN value Press the ESC button to return to main measuring screen 4 9 TIME and DATE settings aJ r1 cI J PE 22838 4 rq E c3 r1 7d 2 cI EZ 4 70 C2 4 Lr Lr L1 Ln r1 9 4 ra a Cj E Dons cae r3 Tiap fg uto sg C3 E F cJ 8 c3 I l c3 1 l E g c l c l ca c3 La ra 4 rq egg L7 rq EJ cI E Press the ESC button to enter the menu Press the Y button and select CON FIGURATION and press the ENTER button Press the Y button and select SYST CONF and press the ENTER button Press the Y button and select SET CLOCK and press the ENTER button Insert date with the V A buttons dd mm yyyy press the ENTER button to move dd gt mm gt yyyy and press the ENTER button Insert time with the A buttons hh mm ss press the ENTER button to move hh gt mm gt ss and press the ENTER button Press the ESC button to return to main measuring screen BCs220AV SATRON VC Optical Consistency Transmitter Revision 1 Table 1 The content of error word 1 E
6. Esc Press the ESC to move back towards the top of the main menu or cancel the current action 3 0 MEASUREMENTS VALUES MENU When the analyzer is powered up it immediately shows the MEASUREMENT VALUES ET Use the UP DOWN keys to move in the menu The menu does not have any variables adjustable by the user Pressing DOWN shows you the following parameters in order the user calibrated information 9o Cs HORR MH the value of the first mA loop di the temperature of the sensor head the temperature of the electronics active recipe name BCs220AV Revision 1 15 3 2014 Under the main menu are 6 submenus Configuration New Sample Calibration Diagnostics and Advanced To enter these submenus press ESC for 3 seconds 3 1 Configuration The transmitter configuration settings RCP SEL PLP SEL Active recipe selection menu RECIPE1 RECIPE 1 Recipe selected options RECIPE 1 4 The basic factory tuning is stored in the recipe 1 To perform a new calibration is recommended to use a new recipe MAOUTPUT MAUUTRPUT The current output circuit settings LRV P Lower range value 4 mA URV URV Upper range value 20 mA TI HM 4 we Mt DAMPING Time constant in seconds for output damping The range is 0 000s to 60s Set the value with the UPIDOWN keys and accept it with ENTER or press ESC if you do not want to change the value AVERAGE ERAGE Time constant in Hz for averaging the ou
7. M MANUFACTURER Manufacturer s name SATRON Cannot be changed TI L J n H L DEVICE TYPE The type code of device Cannot be changed VERSION Version numbers of the transmitter s electronics and software Press ENTER to select this item Press ESC to exit With the UP DOWN keys you can select either CPU HW CPU SW ADC HW ADC SW or MAN REV manual revision revision number or CPU ID number from this submenu ASSEMBLY NUMBER 55 The analyzers assembly number Press ENTER to select this item Press ESC to exit For instance assembly number 0901 shows that the transmitter was made in week 01 of the year 2009 SERIAL NUMBER SER NOM Serial number Cannot be changed CT TWh I L OPERATION TIME Ur The value of the operation time save at 1 hour intervals When the value of the counter is 100 hours so value save 1 minute intervals The value of the operation time counter on the display HH MM SS when the value of counter is 100 hours HHHH MM when the value of counter is 100000 hours HHHHHHHH when the value of counter is 2100000 hours I O CONFIGURATION 1 0 CONF Configure parameters that have an effect on the INPUT and OUTPUT relays VC transmitters with N and L housing Satron highly recommends the use of the software package VOadviser to alter these settings pr Settings menu for input output I O 1 3 housing type N or input PIN 1
8. it for 4 mA output and the third ENTER for 20 mA output The next ENTER after that will give default value 12 mA which can be changed as desired with the UP DOWN keys The last ENTER will switch the transmitter back to normal mode AUTO ON The purpose of this test is to test the accuracy of the transmitter s current output with a reference meter 13 15 3 2014 TRB TRIM PJ TRIM The transmitter calibration factory units FU TRB ZERO measurement of zero Calibration of measurement by two points LRW TRIM calibration of the lower point UPR TRIM calibration of the upper point REMOVE delete of calibration SENSOR TEMPERATURE TRIM TRIM Sensor Temperature Trim Here you are able to calibrate the temperature probe which is placed in the head of the analyzer Maximum by 10 degrees LOOP CALIBRATION LHOPLHL Here you can calibrate the current signal given by the transmitter The first ENTER will switch the transmitter off from normal mode AUTO OFF The next ENTER will make the transmitter give out a signal which it assumes to be 4 mA Use the UP DOWN keys to change this value in accordance with the reading on the reference meter Then press ENTER for 20 mA output which you must also set in accordance with the reference meter Press ENTER to accept the new reading Note Use a sufficiently accurate reference meter TEST Peeves The digital inputs and outputs as well as the power out put of the second test In
9. not function if digital output is over ridden by HOLD function when performing a I O test in the DIAGNOST menu or with HART CPU Control DOOverride BCs220AV Revision 1 15 3 2014 IO2 SOURCE 10g SRE The source for 2 nd mA out PV ST ET 102 LRV tue LRV The lower range value for 2 nd mA out 4 mA TMJ 102 URV uc The upper range value for 2 nd mA out 20 mA Tele LIT gt lO2 DAMPING 420 JAM The time constant for 2 nd mA out 0 60 s 3 2 NEW SAMPLE SAMP The new sample menu START 7 otore a new sample to memory SAMPLE H O 5HHPLHeU Restore the water point to memory 3 3 CALIBRATION The calibration menu RECIPE RECIPE The settings for active recipe OFFSET UFFAET The offset correction for calibration default 0 0 GAIN GALI The gain correction for calibration default 1 0 UsER PNTs USERPNTS The number of points for multipoint calibration POINT CNT calibrated count the number of points 1 16 Their point of entry is given a number in either the keyboard EDIT or by saving the real time mea surement SAMPLE Point out the value of the pair user selectable unit is given a number in the keypad See the section of this manual for an example of tuning to get more information on the complete re calibration USER MODE USERMUGE Select the method of interpolation between the points INTERPL SPLINE Select a linear interp
10. sample point SAMPL 01 09 for 1 point calibration and press the ENTER button Press the ESC button 1 point calibra tion no second point The display rolls the new calculated OFFSET GAIN values Press the ENTER button to store or the ESC button to cancel Press the ESC button to return to the main measur ing screen 4 6 2 Point calibration 2 point calibration with two sample points co 3 48 cJ I 4 c r1 La p rq E e Ta 9 J 9 rq A A A AJ 4 Ln E 2 9 A rq m r1 d cue 44 E 44 I 4 r r gJ rq rq Eu Ad 4 J d r3 ri 29 2 8372588 La E r4 a Ed d 29 4 16 Press the ESC button to enter the menu Press the Y button and select CALI BRATION and press the ENTER button Press the Y button and select CALI BRATE and press the ENTER button Select with the V A buttons the first sample point for calibration SAMPL 01 09 and press the ENTER button Select with the Y Il A buttons the sec ond sample point for calibration SAMPL 01 09 and press the ENTER button The display rolls the new calculated OFFSET GAIN values Press the EN TER button to store or the ESC button to cancel Press the ESC button to return to the main measuring screen SATRON VC Optical Consistency Transmitter 47 OFFSET adjustment E3 E r1
11. 3 output DOUT 1 3 and IO2 housing type L TYPE Select the function housing type N When NONE is selected in the is turned off To use the digital input to select DIN1 To use the digital outputs select the DOUT1 To use the second current output configurable external input IO2 select EXT only O 2 To use the second current outputs configurable to select IO2 only 3 FUNCTION FUNE C UN The digital input output function settings HI LIMIT the digital output will change its state INFO INFO You can select the device information menu from the Main Menu level with the ENTER key Use the UP DOWN keys to view these items Press ESC key to return to the Main Menu level You cannot change the data displyed in this menu 11 depending on the HI VALUE LO LIMIT the digital output will change its state depending on the LO VALUE SATRON VC Optical Consistency Transmitter ERROR AL the digital output will change its state when there is an error WARNG AL the digital output will change its state when there is a warning ERWNG AL the digital output will change its state when there is a error and or warning HOLD when the digital input is ON the whole unit will be in a hold until the input is OFF NONE no function OFT ACKN the digital input mode ON setting off a timer to overfeed digital input status ON increase the number of active pre scription for one RECIPE 1 or two RECIPE 2 i
12. Ln r1 z L pu 5 5 rq Ag Fr H 4 i e ux pu 20 AJ 4 d u A rq q A ns a 4 ra CI Us 5 f nj e mca apaga e OCE m cJ cJ 88 cJ E Press the ESC button to enter the menu Press the Y button and select CALI BRATION and press the ENTER button Select RECIPE and press the ENTER button Select OFFSET and press the ENTER button Place the decimal separator with buttons and press ENTER button Insert the OFFSET value with the V and ENTER buttons until up per separator reaches the right end of display Press the ENTER button to store the OFFSET value Press the ESC button to return to main measuring screen 4 8 GAIN adjustment a rq r1 cI 25 er CI r1 235 r 29 AE i Ed S un 9 4 a 3 4 9 cI ca EC L3 X1 E L3 E r1 m 25 Qu qu cI 4 ra L3 cI d Press the ESC button to enter the menu Press the Y button and select CALI BRATION and press the ENTER button Select RECIPE and press the ENTER button Press the Y button and select GAIN and press the ENTER button Place the decimal separator with Y lI buttons and press ENTER button 17 L c1 Ld La Fy A
13. W1 0 15 Bi 1 Sensor temperature ST error Electronics temperature ET error Percentage of output under 10 or over 110 error ULL so EEPRR ER EEPROM checksum error EEPRW ER EEPROM write error 11 EECAL ER EEPROM calibration error 12 HART ER HART communication error 13 INTRN ER Internal system error OFTMR WA Overfeed timer warning Es es 5 SATRON instruments Satron Instruments Inc www satron com P O Box 22 Fl 33901 Tampere Finland Tel 358 207 464 800 Telefax 358 207 464 801 18
14. come status is displayed on the screen and change the status of the outputs HARDWARE HHBRSHHRE VOLTAGES the voltage diagnostics COMM device O communication diag nostic diagnostics only housing type L LOG LU ADD TXT text 8 characters increase in the event log DATA LOG data log mode CYCLIC continuous default DIC I O selected with digital inputs OFF off BCs220AV Revision 1 15 3 2014 SATRON VC Optical Consistency Transmitter Q3ONVAGV O JHVAAQHVH lSdl WOdO00 1 Wildl 15 NIHIL 9 1 LSL dOO SNLVLS ISONSVIG ai Iv g Ivo LO Id VS IdNVS LO ldIAVS Sa IdNVS ETEN SGOW SSN SINd H3Sn NIVO 1353430 3diodM IVegrivo dV ZO Aan 201 201 ZOI OUS 30 EEF CAVIS NO Ecg ROINNT EN LINA Ad L O JNOO AOVNONVI AWIL dO AHOLOVJ WAN Yas QHOMSSVd INSSV AV IdSIG 5 LYVH ASG MIO 1IOLAS YLOANNVIN EA O3NI JNOOLSAS dw soiuo4129 3 9 4 3 Lnd LO VIN duie Josueg 9 4 S doo 1u8un2o YN LYVLS DEC d LHVLIS 195 yun Aouaysisuog dINVS MIN YNOISNOO MAIN MENU 14 SATRON VC Optical Consistency Transmitter 4 SETTINGS 4 1 Basic settings fafa wrt Press the ESC button to enter the menu Esc Select CONFIGURATION and press the N ENTER button AFA GF Press button and sel
15. ect MAOUTPUT CY and press the ENTER button aput m PrEP Select LRV mA output lower range value 4mA and press the ENTER button nnnnnnnn Place the decimal separator with the B and press the ENTER button mmmmnmnmnm Insert lower range value 4 mA with the eee EW A and press ENTER button until CV LA upper separator reaches the right end of display pnmo Press ENTER button to store the lower range value for mA output Press the V button and select URV CY mA output upper range value 20mA and press ENTER button Place the decimal separator with Tranmere V A buttons and press ENTER button ummnrnmrnmnmm Insert upper range value 20 mA with the V A and ENTER buttons until upper separator reaches the right end of display OMe n Press ENTER button to store the upper H range value for mA output E a gp Press the Y button and select DAMP DAMPING ING time constant for mA output damp ing and press the ENTER button m but with ENTER 1 button and press the T button SHVE 7 MUT Press the ENTER button to store the time n constant for mA output damping APARATY Press Y button and select ALARMTYP and press the ENTER button J1 MH Set alarm current with the V but tons 3 7 or 22 5mA and press the LA Y ENTER button prem 15 BCs220AV Revision 1 15 3 2014 Press the ENTER button to
16. f the recipe is O SEL the digital input mode ON to reset the value of the consistency of the factory the digital input mode is ON storing data logging is permitted if the DATA LOG parameter is set to DIGITAL I O RECIPE 1 RECIPE 2 TRB ZERO DATA LOG FLSH ON the digital input mode ON to set the flush mode to ON FLSH OFF the digital input mode ON to set the flush mode OFF FLSH OVT digital output is for flushing guidance PTT SOURCE SOUFLE Select the source to which the digital output will change its state PV is the process value selected by the user value which is behind U on the display MA is the 1st current loop ST is the sensor temperature located 5 millimeter behind the optical lens RANGE this will show a 0 to 100 value correlating to 4 20mA ON DELAY UN On delays can be used to delay digital output state from OFF gt ON transitions The time can be selected in seconds in the range of 0 300s By default the off delay is not used OF DELAY Ur JELAY Off delays can be used to delay digital output state from ON gt OFF transitions The time can be selected in seconds in the range of 0 300s By default the off delay is not used OF TIMER UF t1MER Overfeed timer limits the time that the digital output can be continuously in ON state The time can be selected in seconds in the range of 1 60000s By default the overfeed timer is not used Note overfeed timer does
17. installed as a general rule turbulence flow Recommended installation location 1 An alternative mounting location 2 The mounting angle of the coupling A 90 105 2 Minimum 2 x D 2 Minimum 1 x D Minimum 2 x D Minimum 1 x D Figure 1 1 Recommended mounting location BCs220AV SATRON VC Optical Consistency Transmitter Revision 1 15 3 2014 1 2 Installing the transmitter a aa eae os p 4 I 4 jeep IST air e p 4 9 use uc 1 Ensure that the installation valve is clean from process media which could dam age the transmitter prior to inserting the transmitter into it 2 Insert the transmitter into the valve and turn to fasten the valve coupler Tighten ing torque 40 Nm o Align the installation tool slots C1 and C2 with the transmitter slots and connect the installtion tool 4 Turn the installation ball valve fully open and insert the trasmitter into the process by turning the installation tool lever clockwise Figure 1 2a Mounting the transmitter on the coupling 3 SATRON VC Optical Consistency Transmitter Desin 15 3 2014 ZZ CEA 22 p IX RE mem nn du Z ga 22 2 N
18. mple point co a 3 71 rJ E c E La 4 LA 44 9 l1 g zd a _ 81 ea 7H g 4 r1 Eu AJ AJ rm r1 _ IF bg J FE rm AJ Eg 4 Eg 3 5 2 5 rx C3 Ca HE r1 29 2d 29 3 m Ko E E 29 29 ca E 4 5 rq co 2 29 ED Eo fe cJ k E c r1 70 La aS a Fu Lx B Ed S un a 9 a 3 4 9 4 8 r1 ul 22 A A mq r1 _ FALIm x RS Fr rq rq 29 Lia 4 Press the ESC button to enter the menu Press the button and select CALI BRATION and press the ENTER button Press the Y button and select CALI BRATE and press the ENTER button Press the button and select the SAMPLEH O to be the 1st calibration point and press the ENTER button Press the Y button and select the sec ond point for calibration SAMPL 01 09 and press the ENTER button The display rolls the new calculated OFFSET GAIN values Press the ENTER button to store values or press the ESC button to cancel Press the ESC button to return to measuring screen 1 Point calibration Press the ESC button to enter the menu Press Y button and select CALIBRA TION and press the ENTER button Press the Y button and select CALI BRATE and press ENTER button BCs220AV Revision 1 15 3 2014 Press the Y button and select the
19. nu you play will be read BACKLGHT Select the intensity of the backlighting from OFF LOW MEDIUM and HIGH ANGLE lets you select the angle of the text NORMAL From left to right Transmitter mounted hori zontally with process connection directed to the right ROTATED Rotates the text 180 degrees from NOR MAL se elect the looks in which the dis T PASSWORD PHaO5 5WLh 2 From this menu you can set a password 0 999 for the analyzer If a password has been specified you cannot set any parameters or make any other settings on the analyzer unless you enter the correct ID number in this menu Password is not in use when PASSWORD is 000 after reset You enter the PASSWORD in the same way as TAG PASSWORD will be on when you define a value between 1 and 999 If you forget password get on to Satron Instruments Inc FACTORY Restore Factory settings After entering this menu you will get a warning message that the configurations will be lost after this point To cancel the procedure press ESC LANGUAGE CHNBUHBE Select the Display language ENGLISH FRENCH T UNIT 1 UNIT Selected the temperature unit from this menu The unit can be Celsius C or Fahrenheit F T T e PV UNIT PY UNI Selected the unit for process value in the display from this menu mg l CS LED CURR EE 9 curr the LED intensity settings Select the amount of current which is used for LED 76 BCs220AV
20. olation Select the spline curve with interpola tion TEXT FEM Select the user name for the recipe 12 BCs220AV Revision 1 SATRON VC Optical Consistency Transmitter SAMPLES SAMPLES The history of the sample 10 Laboratory values input SAMPLE 01 SAMPL WI Upload a sample 1 SAMPLE 09 SAMPL Upload a sample 9 SAMPLE H O SHHMPLHeD The water value CALIBRATE CALLISPA Calibration with sample 1 2 point PL SAM SHHMPL ug c3 SAMPLE 01 SAMPLE 09 SAMPLE H O SHHPLHeEU The calibration list of suitable samples samples recorded fed laboratory value CALIBRATION HISTORY LALISPAT Transmitter calibration history pto The date time stamped list of calibrations 3 4 DIAGNOSTICS 3iHbnuda This submenu allows you to examine the transmitter s internal errors and faults to set the transmitter to give out a fixed current and to calibrate the transmitter STATUS Here you can display and reset accumulated errors one at a time The text OK will be displayed if there are no errors Possible error messages alarm means a serious fault error that also puts the current signal in fault status and makes the display blink Table 1 the content of error word 1 page 18 LOOPTEST LUUPTES The transmitter can be set to give out a fixed current sig nal for testing the mA output The first ENTER will switch the transmitter off from normal mode AUTO OFF the second ENTER will set
21. pply voltage and load capacity Figure 1 12 Wiring Housing with PLUG DIN43650 and M12 connector test connector box codes HT and HS BCs220AV Revision 1 15 3 2014 Position selection 3 x 90 1 Remove screw 2 Open Tighten the screw Figure1 9 Removing the PLUG junction box Figure 1 11 Wiring Housing with M12 connector code HT Figure 1 13 Wiring housing with PLUG DIN 43650 connector code HS SATRON VC Optical Consistency Transmitter Selection window for 1 0 functions remote display VO types VO remote transmitter Automation system System digital output 1 loop 4 20mA gt i 24 System analog i OV DIGDIGNDIGND GND 24v 2 loop 4 20 mA Loop1 u ipu 24V Supply VO Digital output mA Loop2 for loop 2 input Int Vsup Ext Vsup System digital input Figure 1 14 Wiring Remote electronics housing with display code L BCs220AV Revision 1 15 3 2014 15 3 2014 2 SETTING UP 2 1 Setting up with Satron VoAdvisor Service Software When you want to have all the operations of the Smart transmitter we recommend the use of Satron VOadvisor Service Software program Satron Instruments Inc will deliver you the program HART modem and HP 2133 Mini Note PC according the order amp Start Window VOAdvisor software HP 2133 Mini Note PC Si Tool Hart modem package for SATRON turbidity transmitters
22. store the alarm current value Press the ESC button to return to the main measuring screen Press the ESC button to enter the menu Press the Y button and select NEW SAMPLE and press the ENTER button Press the ENTER button and activate sampling The screen will blink SAMPLING text dur ing sampling process Press the ENTER button when sample has been taken to end sampling The sampling time stamp average and min and max cs values during the sampling process are shown on display Press the ENTER button to store the sample or press ESC to cancel 4 3 Laboratory values EJ cJ a M r1 cJ C2 7g AH 3 X cl a Ed E 22 4 r1 Press the ESC button to enter the menu Press the Y button and select CALI BRATION and press the ENTER button Press the Y button and select SAM PLES and press the ENTER button Select with the V buttons the desired sample point to which labora tory value will be inserted and press the ENTER button Place the decimal separator with Y buttons and press the ENTER button Insert the laboratory value with the Y and the ENTER buttons and press the ENTER button until upper separator reaches the right end of display Press the ESC button to return to the main measuring screen SATRON VC Optical Consistency Transmitter 4 4 Start up calibration 2 point calibration with water and one sa
23. tput The range is 1Hz to 50Hz Set the value with the UP DOWN keys and accept it with ENTER or press ESC if you do not want to change the value ALARMTYP HLRRMT Y The alarm current 3 7 mA or 22 5 mA SYSTEM CONFIGURATION SYS7TEON configure parameters that have an effect on the een like e g language and date TAG TAG Tag code You can enter free format text one character at a time When you select this option with ENTER the cursor will be at the left Select characters with ENTER to the right and ESC to the left You can view the se lectable characters one character at a time with the UP DOWN keys until the desired character is found When the cursor is at the right edge you can go back to the SYSTCONF menu either by accepting the new tag code with ENTER or by pressing exiting without changing the tag code by pressing the ESC key when asked to accept your entry Apostrophe indicates the cursor position at point however the cursor will disappear A great deal of special characters are available besides letters and numbes 10 SETCLOCK SETLLDLK Aika ja pvm pp kk vvvv hh mm ss asetukset HART Tassa valikossa tehdaan Multidrop toiminnan ase tukset Multidrop toiminnassa kaikkien multidrop vaylaan asetettujen lahettimien lahtoviesti asettuu 4 mA iin Osoitteella 0 on k yt ss 4 20 mA n virtasilmukka jolloin lahetin toimii normaalisti 4 20 mA signaalilla DISPLAY In this me