Contents

1. Timer resets when power comes ON Timer resets when power comes ON Timer resets when power comes ON SOURCE H Lai i i i i SOURCE Hl i L Hl i Hl SOURCE TEI Dp iei Er A if T ar a E ae oe eee sat a a i wa ee pe eH Us Control output i Te t Control output Reset ore ere Set value 1 Set value LH UP uP Control output ANM i i er i T 0 0 Setvalue Set value f Set value 0 if Li Pere I ec Timing starts when the start signal goes ON Note1 Timing starts when the start signal goes ON or OFF DW HUY Peal ok T UTAS The status of the control output is reversed when time The status of the control output is ON when the start The control output is ON when the start signal is ON is up OFF at start signal goes ON or OFF except when the power is OFF or the reset is ON The timer is reset when the time is up E Interval F Cumulative Timer resets when power comes ON Timer does not reset when power comes ON SOURCE 1 Witt tH 1 a ee SOURCE i l i 1k p Ap TAO ik ik ft 2 s i i La giii brad 1 tig tt ita tad ut TE ren r a e ttt 88 to Gale h e e Reset eo p aE a E Reset a oe een Note1 While the start signal is ON the timer m starts when power comes ON or when Control output Control output p sate Ea r a yp state the reset input goes OFF 0 0 Set value Set value Timing starts when the start signal come
2. Output 1 Output 2 Present value and output 1 maintain status until reset Output 1 and 2 operate independently Up Down Up Down A B C Reset 999999 Preset 2 Preset 1 0 Output 1 Output 2 H5DA 8M 4 DC50mA OUT2 SOURCE SOURCE N L HSDA 11D RESET CP2 START CPI GA Common OUT SOURCE N L H5DA 11M RESET CP2 START CPI GATE Fy K P ee Common OUT2 sd C50mA SOURCE N E K P Key Protection Schematic of HSDA 8M amp HSDA 11M with sensor or contact NPN type SENSOR H5DA V 9 gt INPUT S P 4 ov PNP type SENSOR H5DA et V S M 7 To INPUT oV TIMING CHART TIMER A Signal ON delay 1 A 1 Signal ON delay 2 A
3. Timer dose not reset when power comes ON Timer resets when power comes ON Timer dose not reset when power comes ON SOURCE SOURCE SOURCE 1 I tok ppt pi Ph tk i ht i Hatt py Start Start Start ee AiE i i y i D Gate Gate Gate E a ETETE H mo Reset Reset Reset 1 Control output Control output Control output i 1 i 1 Set value Set value Set value 4 UP UP UP ji 0 0 0 Set value Set value Set value a 0 Timing starts when the reset input goes OFF Timing starts when the start signal goes ON Note1 Timing starts when the start signal goes ON Note1 The start signal disables the timing function ie same The status of the control output is reversed when time is up The status of the control output is reversed when time is up function as the gate input OFF at start OFF at start The control output is controlled using a sustained or one shot time period B 2 Repeat cycle ON start C Signal ON OFF delay D Signal OFF delay
4. n 5 LA 1 1 je 1 I Inhibit gt d d d j 1 n 1 n 2 Up Down B Individual input mode One shot output from Output 2 Self holding output Up Down A B C Set the same counting speed for CP1 and CP2 when in Up Down C mode CONNECTION N type Surface Mounting Use only P2CF 08 8 pin PFO85A 8 pin or PF113A 11 pin Socket Y type Flush Mounting Use only Y50 Frame amp US 08 8 pin P3G 08 8 pin or P3G 11 11 pin Socket Note 1 For NPN input select b 1 for Counter and 8 1 for Timer Common 0V Note 2 For PNP input select b 2 for Counter and 8 2 for Timer Common V 999999 i 1 Output 1 7 1 1 Output 2 i 1 1 1 i 1 1 i i i i 1 i i T T T T T T T 1 1 1 1 1 1 1 Preset 2 i 1 1 1 1 1 Preset 1 PaRa FASE 1 1 1 1 1 1 1 0 a 1 1 1 1 1 1 1 1 1 1 1 Mode F Present value display runs continuous Up Down Reset 999999 Preset 2 Preset 1 0 Outp
5. H5DA Sb Se UE This manual uses the following symbols to ensure safe operation of this timer gt MULTI FUNCTION DIGITAL COUNTER TIMER User s Manual A WARNING Warnings are indicated when mishandling this product might result in death or serious injury ANLY to user A CAUTION Cautions are indicated when mishandling this product might result in minor injury to the user or only physical damage to the timer AN WARNING RESTRICTIONS ON USE gt Note this incorrect wiring of this product can damage it and lead to other hazards Make sure the product has When using this product in applications that require particular safety or when using this product in important facilities please pay attention to the safety of the overall system and equipment Install fail safe mechanisms perform redundancy checks and p eriodic inspections and adopt other appropriate safety measures when it is necessary This product is rated at Class II been correctly electric shock wired before turning the power ON Before wiring or removing mounting the product be sure to turn the power OFF Failure to do so might cause Do not touch electrically charged parts such as the power terminals Doing so might cause electric shock Do not disassemble the product Doing so might cause electric shock or faulty operation CAUTION Use the product within the operating ranges
6. Lock reset key FB K A i Power off reset K b nPn K Counter Ee i 4 3 Lock preset value key A 2 Power off memory b g PnP 2 Timer 4 3 4 Lock all key l fe Se BeBe eae BESS SSS SSeS Se See eneHese SS See 24h bese ee aeae e222 2285342444 432552558466 2252 2552824224442 2582585 a Timer 1 TIME RANGE 2 UP DOWN MODE 3 OUTPUT MODE i 1 999 9995 1 5 99M59 99S 1 4 99H99M59S 3 ModeA 3 5 ModeB 3 9 ModeD __ f 2 9999 998 i amp 999M59 9S 1 A 9999H59M K g Count up K 3 2 ModeA1 3 amp ModeB1 3 A ModeE B i 3 99999 9S 1 7 99999 9M i b 99999 9H g Count down 3 3 ModeA2 3 7 ModeB2 3 b ModeF F l i 4 999999S i 8 999999M i 999999H 3 4 ModeA3 3 8 ModeC proccc ccc ccc rrr fee 5 5 5 e a i i 4 OUTPUT TIME 5 INPUT SIGNAL TIME 6 KEY PROTECTION LEVEL 7 OUTPUT CONTACT Only for H5DA 11 and HSDA 11D 11 4 4 Hod 4 5 58 amp Lock function key E 3Sec i 4 2 048 4 6 108 Eb 5 20ms BBs 5 2 Lock reset key Ke 3 1 2 Ee 4 3 0 58 4 7 15S 5 2 1mS 6 7 Lock preset value key 7 2 1MC E 4 4 18 4 8 20S 6 4 Lock all key r J l i 8 NPN PNP INPUT MODE 9 FUNCTION MODE i 8 Pn K 4 Counter lt S 8 2 PnP 9 2 Timer 7 Product is subject to change without notice TIMING CHART COUNTER Input Modes and Count Value Please note 1 A indicates m
7. 2 Power ON delay 1 Control output Control output Timer resets when power comes ON Timer resets when power comes ON Timer resets when power comes ON SOURCE E EE SOURCE EA ia SOURCE EE a poi ot gii aa D tot ggi mi E E EE F Gale fr Gats Egan i od ht dda roto itd TE i E E Reset i t Reset t Reset t mt pat Tritt 4 ryt riturnu gt L Contro output mme te mie eta Se eke ere ea Set value Set value Set value 0 0 0 Set value Set value Set value 0 Timing starts when the start signal goes ON Note1 Timing starts when the start signal goes ON and is reset Timing starts when the reset input goes OFF The control output is controlled using a sustained or when the start signal goes OFF Note1 The start signal disables the timing function ie same one shot time period The control output is controlled using a sustained or one function as the gate input shot time period The control output is controlled using a sustained or one shot time period A 3 Power ON delay 2 B Repeat cycle 1 B 1 Repeat cycle 2
8. inimum signal width B indicates 1 2 of minimum signal width Signals may not be counted if the minimums for A and B are not met 2 Hand L Signal No voltage input Short circuit Open circuit Up increment mode Count at rising edge H CP1 LA Inhibit i H i I CP2 i L j i l 3 i 4 Count i i 2 14 0 0 Up increment mode Count at falling edge H p CP1 L 1 ma 1 1 A inhibit H cP2 t Ve TE __4 Count i 0 0 Up Down A Command input mode H CP1 r H i i i cp2 t ig s Count i P3 2 0 0 Up Down C Phase difference input mode See note 1 H CP1 L p 1 1 1 1 B 7 i 1 i a i i i i i pot rt ne Poi Count 9 19 1 0 One shot output from Output 1 Output s Self holding output Mode N Output and present value display are maintained until reset Reset Down CP1 CP2 Count CP1 CP2 Count CP1 CP2 Count Note 1 Down decrement mode Count at rising edge Ban i A Inhibit
9. recommended in the specification temperature humidity voltage shock mounting direction atmosphere and etc Failure to do so might cause fire or faulty operation Firmly tighten the wires to the socket Insufficient tightening of the wires to the socket might cause fire SPECIFICATIONS NAMES AND FUNCTIONS OF FACEPLATE Operating voltage AC DC 12 48V AC DC 100 240V Allowable operating voltage range 85 110 of rated operating voltage Rated frequency 50 60Hz Contact rating 250VAC 5A Resistive load Count speed MAX 30 1k 5k or 10k cps Power consumption Approx 2 5VA LEDs COUNTER Counting indicator TIMER Timming indicator Out1 Out2 Control output 1 2 indicator RESET Reset indicator CP1 CP2 Signal input 1 2 indicator Start Start signal input indicator Gate Gate signal input indicator KIP Key protection indicator Upper display Display present value or setup items Lower display Display set value or parameters J key Shift cursor or switch mode Life Mechanical 5 000 000 times Electrical 100 000 times Set1 Set2 1st 2nd set value indicator Total Total value indicator hr min sec Time unit indicator MAX 85 RH mkey Reset the output or save the set value then back to the operation mode Ambient temperature 10 50 C key Increment and decrement numeric values and
10. s ON Note1 Start signal enables timing timing is stopped when the start The control output is reset when time is up signal is OFF or when the power is OFF A sustained control output is used DIMENSION mm H5DA H5DA Y 50 US 08 Te m l _ F l lt Y L fl R L s l oe 63 7 453 t alee 48 7 35 7 4 45 35 M H5DA I A ANLY ELECTRONICS CO LTD http www anly com tw Printed in Taiwan
11. sly Output 1 is self holding and goes off after expiration of the 1 shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Up Down A B C Reset 999999 Preset 2 Preset 1 0 Output 1 Output 2 Present value display does not change during 1 shot time period but reset start status is returned to as soon as count is reached Outputs are 1 shot and operate repeatedly Output 1 is self holding and goes off after expiration of the 1 shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Up Down A B C Reset 999999 Preset 2 Preset 1 0 Output 1 Output 2 Present value runs continuously through 1 shot time period and returns to reset start status immediately afterward Outputs are 1 shot and operate repeatedly Output 1 is self holding and goes off after expiration of the 1 shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Up Down A B C Reset T 999999 Preset 2 Preset 1 0
12. switch betwen Set1 Set2 display Ambient humidity Weight Approx 118g SETTING PROCEDURE e COUNTERIOR TIMER S VALUES RESET lt i SWHCHTO THE MODE SETTING STATUS Sye o S ONOFF Key protect a a Ec SWITCH TO THE NEXT MODE gt ISAVE AND BACK TO THE ORERATION STATUS mma a h lt Se Wo lt m Counter 1 INPUT MODE 2 0UTPUT MODE 3 OUTPUT 2 TIME 4 OUTPUT 1 TIME i i UP i 5 UP DOWN C g ModeN 2 5 Mode K 3 1 0 01S 3 5 058 3 9 10S 4 7 Hold 4 5 02S 4 9 5S i DOWN g ModeF 2 amp ModeP 7 2 0 05S 3 6 18 J A 208 4 2 0 01S 4 6 05S 4 A 10S 3 UP DOWN A lt 3 2 3 ModeC 2 7 Mode Q lt 3 3 3 014S 3 7 28 K 4 3 0 05S 4 7 1S 4 b 20S B 1 4 UP DOWN B 2 4 ModeR 2 amp ModeA 3 4 025 3 8 5S 4 4 018 4 8 28 poccc ccc ccc rrr fee ee 5 5 5 J l l 5 COUNT SPEED 6 MINIMUM RESET TIME 7 DECIMAL POINT 8 PRESCALE VALUE ti 5 30 cps 7 999999 5 2 tkeps Bo 5 20m8 E 3 2 99999 9 Fe o0 001 39 999 K 5 3 skops 5 2 1mS 7 3 9999 99 Bi i 5 4 10k cps 7 4 999 999 proccc ccc ccc rrr ee 5 5 5 5 5 e ra 9 KEY PROTECTION LEVEL 10 POWER OFF MODE 11 NPN PNP INPUT MODE 12 FUNCTION MODE Lock function key B 3Sec Me 4 2
13. ut 1 Output 2 H5DA 8 Input 1 Eg lia Q OUT2 Common SOURCE N L H5DA 8B Input 2 OUT2 Common TIMING CHART COUNTER CONNECTION Present value is placed in reset start status as soon as count up is reached The count up is not displayed Outputs are 1 shot and operate repeatedly Output 1 is self holding and goes off after expiration of the 1 shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Up Down A B C Reset 999999 Preset 2 Preset 1 0 Output 1 Output 2 Present value is placed in reset start status as soon as count up is reached Outputs are 1 shot and operate repeatedly Output 1 is self holding and goes off after expiration of the 1 shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Up Down A B C Reset 999999 Preset 2 Preset 1 0 Output 1 Output 2 Present value runs continuou