Home
RTi Connect Manual
Contents
1. RTS comic MANUAL POWERED BY BLUE EARTH REESEN CONTENTS INTRODUCTION PONE E 0 INTRODUCTION SUMMARY FEATURES USER 2 APPLICATION INSTALLATION MAC COMPUTER INSTALL WINDOWS COMPUTER INSTALL ENENG OC rate AEN NNN AE EE REENEN 5 PRELAT CONFIGURATION TEEN 6 SYSTEM ceci 0 SYSTEM SETTINGS TIME NETWORK A nn 9 SNMP SETTINGS RTi CONNECT MANUAL INTRODUCTION Through a network connection using standard secure Internet protocols TCP IP remotely or directly connect to the UltraPower Stealth Battery Backup System UPStealth From a desktop application UPStealth Real Time Intelligence Connect RTi Connect will link your computer running Windows or OS X to view monitor and manage UPStealth performance parameters such as System Status Cabinet Load Run times and AC Voltage Direct Connect Remote Connect FEATURES 1 By using the RTi Connect desktop application DOT s and city agencies have the ability to remotely or directly connect to an individual UPStealth to e View individual intersection power status in the event utility power is lost SUMMARY View the battery charge status and runtimes at a specific intersection e View real time cabinet power consumption Remotely or directly link to the UPStealth e Configure Simple Network Management Protocol SNMP communication to by using be notified of
2. downloads Double click on the icon to start the process of installing the app to your computer A downloading pop up screen will appear where you will need to drag and drop the UPStealth RTi Connect icon to your Applications folder Once copied to your Application folder you will find the completed download of UPStealth RTi Connect which is now ready for use Windows Computer Install Once RTi Connect is downloaded from the web to install the application click Open or Install and then follow the instructions on your screen If you are prompted for an administrator password or confirmation type the password or provide confirmation OS X UPStealth RTI Connect setup UPStealth RTI Connect Ready to Install Setup is now ready to begin installing UPStealth RTi Connect on your computer Applications Windows Click Install to continue with the installation RT i CONNECT MANUAL 2 LOGIN Click the UPStealth RTi Connect icon to open the desktop application A login screen will prompt you to insert a Username Password and UPStealth IP address RTi Connect comes with a preset Username and Password The Username is admin and the Password is 123456 Blue Earth EPS recommends going into the System tab in the Security drop down to create your new password The IP Address is u
3. Receiver 255 255 255 255 3 Community public Cancel Save Changes POWERED BY BLUE EARTH BlueEarth e Blueeartheps com Twitter com BlueEarthEPS Facebook com BlueEarthEPS B eeps info blueearthinc com RTi CONNECT MANUAL BLUEEARTHEPS COM RTi CONNECT MANUAL
4. and SNMP Settings SYSTEM SETTINGS The first drop down tab is the System Settings tab which allows users to configure and set several RTi Connect features O St E e 4 RTI UPStealth Name Customize the name of a specific UPStealth unit Each UPStealth Inverter Controller has an IP Address which identifies that specific unit The Naming feature allows you to create a name for the Inverter Controller such as a street address indicating geographical location ex 5th and Main so the user can identify the location High Capacity Mode Enable high capacity mode by clicking the On or Off button This will increase the battery Depth of Discharge creating longer intersection battery backup run time A C Thresholds Set low and high A C threshold values Setting Low and High A C voltage thresholds creates voltage parameters which determine when the UPStealth will be activated Power Monitoring Sensitivity Low Medium or High This feature will allow you to set UPStealth sensitivity to utility power voltage transients KLO is threshold only XHI will respond to very short transients A C Switch Delay This feature delays how quickly the UPStealth switches from utility power to battery power Standard minimum is 6 milliseconds msec Max is 200 msec System Settings UPStealth Name 5th amp Main Enable High Capacity Mode OFf A C Threshold Low 1
5. 00 A C Threshold High 130 Power Monitoring Sensitivity HIGH LA 0 6 ee A C Switch Delay Milliseconds 0 Time Date b Network Security lt SNMP Settings CONNECT MANUAL b System Settings TIME DATE Time Date Set UPStealth System Time 12 hh 00 mm 00 ss Set UPStealth System Date 8 19 2014 m gt Network gt Security gt SNMP Settings The second drop down tab is Time Date By setting Time and Date the system will tag power failures on your Event log with an accurate time stamp 1 Users have the ability to set the UPStealth System Time which should replicate the time of day 2 Users have the ability to set the UPStealth System Date which should replicate the day of the year E Users can press the Synchronize time with local system button to quickly synch the time NETWORK b System Settings b SNMP Settings Time Date Network C DHCP Manual 2 IPv4 IP Address 10 1 10 90 Gateway 10 1 10 1 Subnet 255 255 255 0 Primary DNS 10 1 10 1 Secondary DNS 0 0 0 0 Security The third drop down tab 5 Network which allows the user to configure UPStealth network settings including IP Address DNS Gateway Subnet 1 DHCP Dynamic Host Configuration Protocol This protocol allows the UPStealth to be assigned an IP Address from a DHCP service located on your network The UPSt
6. alid information when asked to do so RTi Connect has security safety parameters within the Relays tab so improper information can not be inserted The relay triggers on the UPStealth Inverter Controller are Or Functions Meaning users can set multiple triggers under one relay The configurations are not prioritized so whenever a relay configuration parameter is triggered that relay will be switched on When you are ready to select a trigger push the Save Changes button A pop up screen will appear to confirm that you are satisfied with the changes you have made If you are not satisfied with the changes you have made you can press Cancel IMPORTANT If you leave the Relays tab without pushing the Save Changes button and confirming by pushing Save on the pop up screen the relays will not be set Relay Configurations are customizable ULTRAPOWER 5th amp Main e i AA Available Runtime 01 05 Voltage Volts 117 Home Event Log Relays System Load Watts 269 Relay Trigger Configuration Power Failure Temperature Battery Capacity Time After Power Relay 1 CY Time of Day Relay 2 Relay 3 Relay 4 EX Relay 5 Relay 6 Relay 7 Relay 8 CONNECT MANUAL 6 SYSTEM The System tab has five different dropdown sections System Settings Time Date Network Security
7. ble waveform to view A C waveform for power failure event at 10 35 16 2 By clicking on an event row and pressing the View Waveform button in the top right corner of the Event Log page you will get a view of that exact waveform u o o gt U lt 3 Next to the View Waveform button is a Refresh button to update the Event Log DS AA ES time ms 4 Inthe top left of the Event Log is the Clear All Events button When you press this button all events will clear Live Waveform Window Q ULTRAPOWER A ann 5th amp Main STEALTH EK di Voltage Volts 118 soni ta 2 e EA e EVENT LOG Refresh View Waveform Time Event Occurred Event Type Duration Minutes Waveform Available Mon Aug 18 10 35 16 PDT 2014 Power Failure Mon Aug 18 09 31 57 PDT 2014 Power Failure Mon Aug 18 09 06 00 PDT 2014 Power Failure Mon Aug 18 08 55 59 PDT 2014 Power Failure 5 CONNECT MANUAL RELAY CONFIGURATIONS The Relays tab will allow you to turn on or off the 8 user programmable relays on the UPStealth Inverter Controller If certain user defined and preset triggers on the Inverter Controller occur such as Power Failures Temperature thresholds Battery Capacity levels Time After Power Failure and Time of Day the UPStealth will activate Some relay configurations are not settable without inputting v
8. ealth will populate the network parameters with default values which can then be overwritten by selecting the Manual option 2 Manual Allows user to specify their own IP Address and network configuration parameters RTi CONNECT MANUAL 8 SECURITY The fourth drop down tab is Security which is where users can configure a new password SE Users have the ability to reset the login screen password that was originally set by Blue Earth Energy Power Solutions SNMP SETTINGS System Settings Time Date Network Security SNMP Settings 1 Reset Admin User Password Enter Password Enter Password again Cancel Save Changes The fifth drop down tab is SNMP Settings which is where the user can configure triggers that will generate messages to be sent to the specified SNMP server receiver 1 The triggers are as followed Power Failure Battery Capacity Remaining Runtime and Heartbeat Heartbeat will send messages to the receiver at the configured interval sec to notify that the UPStealth System is available Receiver The IP Address of the SNMP Server Community The value of your SNMP community string 9 CONNECT MANUAL b System Settings gt Time Date b Network K Security SNMP Settings 1 Power Failure Battery Capacity Remaining Runtime Heartbeat SNMP Traps ar Mor Mor y 2
9. ections of RTi Connect At the bottom of the Home page are graphical charts with two tabs System Load and A C Voltage These graphical charts relay real time UPStealth data In the top right corner of the app is a Status Screen that shows real time data from the UPStealth BBS The live information includes Intersection Name or IP Address Available Runtime A C Voltage Load and what Power Source the traffic intersection is using So E Y Within the Status Screen are battery icons indicating the current status of the UPStealth A lighting bolt in the top ku d left of the green battery icon indicates that the UPStealth is in A C Power Mode If a power failure occurs an orange battery icon will appear indicating the UPStealth is in HERE Battery Backup Mode ULTRAPOWER 5th 8 Main ES T A A T E Available Runtime 01 05 U U U Voltage Volts 8 Home Event Log Relays System System Load Watts 273 O Relay Configuration System Configuration Q Set Date Time Live Waveform User Configuration System Load A C Voltage System Load Watts RTi CONNECT MANUAL 4 EVENT LOG The Event Log page will be your internal look into what has happened inside your traffic cabinet 1 The Event Log will list the Time Event Occurred Event type Duration and if there is an availa
10. nique to each UPStealth Inverter Controller at each installed intersection Users have the ability to configure the IP Address by going to the System tab in the Network drop down The UPStealth IP Address can be found within your physical UPStealth Inverter Controller QG On your LCD display screen select the Menu option 2 Select the More option 3 Select the Ethernet option and you will find the UPStealth IP Address for that specific UPStealth Inverter Controller Once you have entered the required information on the login screen press Login and you are now connected to a UPStealth Username Use er A Password P UPStealth IP __ __ g IT CONNECT _ mg 3 CONNECT MANUAL HOME SCREEN Now that you are logged in and connected to a UPStealth the Home screen will be your internal look into your traffic cabinet D The Home screen was created as a navigation center and host page for real time information from your UPStealth BBS RTi Connect has four tabs that are available to help you navigate to the four pages Home Event Log Relays and System On the Home screen are 6 clickable icons that will helo you navigate to the Event Log Relay Configurations System Configurations Set Date Time Live Waveforms and User Configurations s
11. system status RTi Connect to view and dL the e Assign a geographical location to a UPStealth unit allowing users to quickly system in real time locate and identify the current status of specific intersections as If you were standing in front of the e View the Event Log which allows users to diagnose system power failures cabinet helping save time and resources e View AC Waveforms to help diagnose why an intersection went off line e Setup the control of up to 8 relays remotely e View and manage user programmable menu options Programmable Time and Battery Capacity Relay Triggers Voltage Thresholds and High Normal Capacity CONNECT MANUAL USER MANUAL Welcome to the RTi Connect desktop application a remote or direct connection route to the UPStealth inside your traffic cabinet The following are some easy steps and tips for downloading and operating RTi Connect APPLICATION INSTALLATION The RTi Connect desktop application will be available to download from the www blueeartheps com website on the products page RTi Connect for Mac and Windows is available for downloading through the links Hit Connect for OS X or Hl Connect for Windows These links will prompt you to complete the download of the application Mac Computer Install Once Connect is downloaded from the web you will find the app icon UPStealth RTi Connect in your Finder
Download Pdf Manuals
Related Search
Related Contents
Prestigio MultiPad 5001 8GB 3G Black Bedienungsanleitung - Baumarkt Nadlinger Clover Technologies Group DC357-CC surveillance camera QA-2/QUAD-ARROW DISTORTION COBY electronic TFTV3217 User's Manual Tripp Lite Cat5e 350MHz Molded Patch Cable (RJ45 M/M) - Black, 4-ft. Mark VII Dimmer Bank Users Manual nüviŪ 700er Copyright © All rights reserved.