4500 thermostat installation instructions

image

Contents

1. 0 0 deg C 5 1 5 deg F 0 8 deg C 1 5 deg F 0 8 deg C 6 42 0 deg F 1 1 deg C 6 2 0 deg 1 1 deg 7 2 5 deg F 1 4 deg 7 2 5 deg F 1 4 deg C NOTE DO NOT SELECT 1 1 The following are suggested entries for digits one and two respectively in Field 05 for different types of heating systems 1 4 Hot water heat default 4 1 Hot air or electric heat 6 4 Gravity feed systems Ask the homeowner or HVAC installer about the type of system at the premises Field 06 Announce Thermostat 1 Temperature L not announce thermostat 1 temperature default 1 Announce thermostat 1 temperature as part of the 4286 status report for the security system t is recommended that this field be programmed to enable announcement of ambient temperature so that premises temperature can be monitored when user is away 4500 Thermostat nstallation nstructi ons For Fields 07 09 select the 3 digit word codes from Table 5 for each descriptor If you want less than a 3 word description for the thermostat set unused descriptors to 000 Note Fields 07 through 09 select a voice announcement to be associated with thermostat 1 For example if you wanted a voice announcement for south bedroom temperature you would program Field 07 as 155 Field 08 as 015 and Field 09 as 158 If you only wanted a voice announcement for bedroom temperature you would program F
2. 4500 thermostats THERMOSTAT PORT TO CONTROL TO 4500 PANEL THERMOSTATS m RED BLACK GREEN NO CONNECTION 4500 Thermostat Installation nstructi ons 10 Oncethe 4500 is mounted you need to set its DIP switch and 3 pin fan control jumper These procedures are described below Setting the DIP Switch The 4500 includes a DIP switch for setting the address of the thermostat The 4286 phone access module can include up to 2 thermostats per system These are referred to as thermostats 1 and 2 Set thermostat 1 DIP switch to address 01 If there are 2 thermostats in the system the second must have its DIP switch set to address 02 If there is only one 4500 thermostat in the system program the 4286 for operation with thermostat 1 see the section Programming the 4286 to Add Thermostats If there are two thermostats in the system ask the user which one will be used the most The most commonly used thermostat should be programmed as thermostat 1 since the voice menus allow setting of thermostat 1 as soon as the thermostat setting menu is entered DIP switch set to 01 DIP switch set to 02 5 43 2 1 5 43 2 1 2 2 z z gt gt To assist you in setting the DIP Switches the words UP and DOWN are marked on the 4500 thermostat printed circuit board as shown here The words UP and DOWN shown in the diagram of the DIP switches above are as marked on the therm
3. Instructions 4500 or premises thermostat fails to control the HVAC system l Check set points in 4500 and premises thermostat to ensure they are set properly 2 If BYPASS of 4500 via its front panel switch causes existing thermostat to work properly then problem is in the 4500 wiring or within the 4500 itself If the existing thermostat does not work check its wiring and battery if any 3 Check wiring connections Refer to Summary of Connections diagram Heating and cooling set point does not change according to settings when the system is armed or disarmed l Verify temperature settings with the 99 thermostat mode and that set back is programmed on 2 Verify the entry for control panel type field 02 using the 4286 phone programming mode 3 Ifthe control panel uses non addressable keypads verify that the monitored keypad address set in phone programming mode Field 01 is set to 31 4 fthe control panel uses addressable keypads verify that the monitored keypad address set in 4286 phone programming mode field 01 a Matches a control panel device address assigned to a keypad and b Isassigned tothe partition where the 4500 thermostat is physically located SECTION 7 Appendices In This Section Federal Communications Commission FCC Part 15 Statement Ademco Limited Warranty Summary of Connections FEDERAL COMMUNICATIONS COMMISSION FCC PART 15 STATEMENT This equipment has been
4. and the wire going to the heating control loop W will dose when the temperature drops to 65 degrees The heating system will be activated Figure 3 shows the same system with the 4500 thermostat and 4286 phone module added 4286 PHONE MODULE 4500 THERMOSTAT PREMISES 5 THERMOSTAT Figure 3 4500 Thermostat with HVAC System 4500 Thermostat Installation Instructions If you are installing the 4500 in a heat only system the setup will look like Figure 4 below 4286 PHONE MODULE 4500 THERMOSTAT PREMISES THERMOSTAT Figure4 4500 Thermostat with Heating System Only Some heating systems such as the forced air type have a fan connections are shown Other heat only systems may not include a fan in which case the fan connections are not used If you are installing the 4500 in a cooling only system the setup will look like Figure 5 below 4286 PHONE MODULE 4500 THERMOSTAT PREMISES 5 THERMOSTAT Figure 5 4500 Thermostat with Cooling System Only 3 4 Section 3 Installing the 4500 Thermostat When installing the 4500 thermostat refer to the Summary of Connections at the back of this manual This diagram depicts the 4500 s terminal strip and shows exactly how the thermostat must be wired The heating cooling system and thermostat you are working on may not have all the connections shown All heating systems have R and W connections Heating systems with a fan cont
5. if the product is altered or improperly repaired or serviced by anyone other than Ademco factory service For warranty service return product transportation prepaid to Ademco Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the products it sells may not be compromised or circumvented that the products will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the products will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING However if Seller is held liable whether direct
6. may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment 1 4500 Thermostat Installation Instructions ADEMCO Limited Warranty Alarm Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product or for products not having an Ademco date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise
7. partition as keypad Speaker exclude 04 Assign 4500 to same partiti on as keypad Thermostat No Speaker nam default Do NOT select 04 which is the address of the 4286 Phone Module exdude 04 With no speaker connected the speaker option must still be disabled After exiting the 4286 programming mode use the 97 speaker control menu of the 4286 and choose the MUTE menu selection Refer to Programming opeaker Output Mode on page 3 9 of the 4286 Installation Instructions for more detail Field 01 Phone Panic Address The 4286 will trigger a panic alarm by sending a panic key sequence to the control panel when a phone panic key sequence is entered on a Touch tone phone keypad Refer to the Basic Operating Guide in this manual for details Todisable the phone panic feature enter 00 default Otherwise In a system that uses addressable keypads 1 Select an unused device address 01 31 to be used to send phone panics to the control panel Assign this address to a keypad through the control panel s 93 device programming mode although a physical keypad will not actually be connected Do not select 04 which is the address of the 4286 VI P Module 2 Enter the same address in this field In a system that uses non addressable keypads Set this field to 31 to enable phone panics 4500 Thermostat nstallation Instructions Field 02 Control Panel Type 1 Vista 10 and Vista 10SE Via 30P
8. phone module will announce Check thermostat 1 2 Descriptor instead of the temperature SECTION 6 Troubleshooting In This Section General Troubleshooting Typical Thermostat Se U p Probl ems General Following the procedures in the 4286 Installation Instructions manual should result in a minimum number of system problems If you experience problems that relate to the use of the 4500 thermostat s first check the possible resolution of some typical thermostat problems that follow Thermostat is in check 4286 announces Check Thermostat or the yellow light is flashing on the 4500 1 Check that the DIP switch on each thermostat is properly set and that the 4500 addresses have been properly programmed in the 4286 programming mode 2 Check the connections from the 4286 to the 4500 and make sure that the cable connecting the 4500s to the 4286 faces the correct direction yellow toward the corner of the 4286 board Heat is cycling on and off too often l Increase the amount of span as described in the section Programming the 4286 to add 4500 thermostats in Section 4 of this manual 2 Makesurethat the location where the 4500 is mounted is free of drafts Temperature in the room swings too widely when the 4500 is set to ACTIVE mode l Decreasethe amount of span as described in the section Programming the 4286 to add 4500 thermostats in Section 4 of this manual 6 1 4500 Thermostat Installation
9. tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e fusingan indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the receiver away from the security control Move the antenna leads away from any wire runs to the security control Plug the security control into a different outlet so that it and the receiver are on different branch circuits e f necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer
10. 4 deg 6 2 0 deg 1 1 deg C NOTE DO NOT SELECT 1 1 The following are suggested entries for digits one and two respectively in Field 11 for different types of heating systems 1 4 Hot water heat default 4 1 Hot air or electric heat 6 4 Gravity feed systems Ask the homeowner or HVAC installer about the type of system at the premises Field 12 Announce Thermostat 2 Temperature 1 Announce thermostat 2 temperature as part of the 4286 status report for the security system not announce thermostat 2 temperature default f a second 4500 thermostat is installed it is recommended that this field be programmed to enable announcement of ambient temperature so that premises temperature can be monitored when user is away 4500 Thermostat Installation Instructions For Fields 13 15 select the 3 digit word codes from Table 5 for each descriptor If you want less than a 3 word description for the thermostat set unused descriptors to 000 Note Fields 13 thru 15 select a voice announcement to be associated with thermostat 2 For example if you wanted a voice announcement for central hall temperature you would program Field 13 as 089 Field 14 as 050 and Field 15 as 158 f you only wanted a voice announcement for hall temperature you would program Field 13 as 000 Field 14 as 050 and Field 15 as 158 Field 13 Thermostat 2 Descriptor 1 Default value 0 0 0 announce
11. 86 to Add 4500 Thermostat s In This Section General To Enter and Usethe 4286 Programming Mode Programming Fields amp Step by Step Programming Instructions Thermostat Voice Descriptor Vocabulary General To install the 4286 with 4500 thermostats you must program the 4286 using its installer programming mode This is done using a Touch tone phone at the premises that is wired to the 4286 handset terminals The 4286 installer programming mode may be entered within 3 hours from the time that power is applied toits 12VDC input The installer programming mode options allow you to program the 4286 to Drive 1 or 2 4500 thermostats Set up the system to work in degrees F ahrenheit F or degrees Centigrade C Announce room temperature along with security system status reports Provide voice descriptions for the thermostats such as upstairs bedroom temperature Select the partition that will trigger a temperature set back when the system is ARMED AWAY This is done by selecting a keypad address assigned to the desired partition 4 1 4500 Thermostat Installation Instructions To Enter and Use the 4286 Programming Mode 1 2 Pick up premises touch tone phone connected to the 4286 handset output Enter the 2 digit phone code on the phone keypad If the 4286 is announcing wait until system status announcements have been completed then press 98 The 4286 will announce the contents of progra
12. ADEMCO 4500 THERMOSTAT INSTALLATION INSTRUCTIONS N7970 7 97 rro TN uw Downloaded from http www guardianalarms net Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Table of Contents Application and DesIpEOM arterie QOO BER EDD CUR ER Ra Ha d v EN 1 1 4500 SDeCITICaEI ho ra CU nca LU Ni S 1 2 Mo untIhg and Instal AEON cxi viera ice Ree n oa ce a eC a D 3 2 Wiring Connections ien on ma ton aaa ebbe rea FR paa vl nia RU a 3 2 Step by Step Installation Instructions ans sennnnnennneernnneeennnnnnnennnn vennen 3 5 Setting the DIP S np echa cR 3 8 Setung the F ap Control PINS a 3 9 Programming the 4286 to Add 4500 Thermostat s ass ee eR C O 4 1 To Enter and Use the 4286 Programming 4 2 Thermostat Voice Descriptors 4 9 the 4500 With the 4286 CR bv eaa i es dva e n CU Cd ean 5 1 Step by Step Testing 5 1 Setting the Premises Thermostaten enn nennen nennen nnns 5 2 Setting the 4500 Thermostat nennen nennen nnne nnns 5 2 Menu Selectlor 5 3 G
13. RS VOCABULARY 4286 Phone Access Module Only Thefollowing three digit codes are used to program thermostat descri ptors into the 4286 programming fields 07 thru 09 and fields 13 thru 15 Table 5 WORD DOWNSTAIRS DRIVEWAY DUCT EAST EQUIPMENT EXIT FACTORY FATHER S FENCE FIRE FLOOR FOYER FRONT GARAGE GAS GLASS HALL HEAT INSIDE KITCHEN LAUNDRY LEFT LIBRARY LIGHT LIVING LOADING LOWER MACHINE MASTER WORD INDEX 014 212 145 165 146 012 011 147 058 148 210 WORD WORD INDEX WORD MEDICAL MOTHER S MOTION 156 157 154 062 STATION STORAGE SUN SYSTEM NO NORTH NOT 158 213 TEMPERATURE TOOL 025 UP 187 UPPER 183 UPSTAIRS UTILITY OFF OFFICE ON OPEN OUTSIDE WEST WINDOW WING PANIC PARTITION PATIO PHONE POWER PUMP REAR RIGHT ROOM 5 SERVICE SHED SHOP SIDE SMOKE SON S SOUTH STAIRS STATION STORAGE 4 9 4500 Thermostat Installation nstructi ons 4 10 SECTION 5 Testing the 4500 With the 4286 In This Section General amp Step by Step Testing Procedure Setting the Premises thermostat amp Setting the 4500 Thermostat Menu Selections General Once the 4500 has been installed and the 4286 programmed the system may be tested with the following procedure Step by Step Testing Procedure Perform the steps that follow in order 1 Bypass all interior zones and any others that may cause an alarm while the
14. and Via 30PSE 4140XMP with voice upgrade EPROM 2 Vista 20 Vista 20HW and Vista 20SE default 4 Vista 40 Vista 50P Vista 100 and Vista 120 Field 03 Units of Temperature 0 temperatures in degrees F default 1 temperatures in degrees C If an existing system has its temperature units changed set back temperature s must be reprogrammed to reflect the new values Field 04 Thermostat 1 Enable and Address 00 thermostat 1 disabled not in the system default 01 set address to 01 Field 05 Thermostat 1 Swing digit 1 Swing above set point digit 2 Swing below set point digit 1 2 This field defines how many degrees below the set point the heat will turn on and how many degrees above the set point the heat will turn off These values also define the swing of the air conditioner operation This option is also known by HVAC Heating Ventilation Air Conditioning installers as temperature span or hysteresis t is recommended that the premises HVAC installer be consulted to choose the values to be programmed for optimal HVAC system efficiency The following table indicates the proper programming settings for the adjustment of the thermostat in this field Section 4 Programming the 4286 to T hermostat s Thefirst digit indicates the swing above the set point the second digit indicates the swing below the set point as indicated below Temperature Span Swing ABOVE BELOW 1 0 0 deg
15. be disconnected and then re connected with the 4500 as shown in Figure 3 Refer to the Wiring Connections section below to understand how the 4500 and existing thermostat are connected Wiring Connections 3 2 Before you can understand how the 4500 is connected you should first understand how the existing thermostat and HVAC system is connected These connections are shown in Figure 2 below Rc THERMOSTAT Figure 2 HVAC System with Existing Thermostat As you can see there are a total of five wires connected between the existing thermostat and HVAC system Thefirst two wires R and Rc are used for loop power e powers the heat loop and sometimes the fan loop e Rcpowers the cooling loop and the fan loop Section 3 Installing the 4500 Thermostat Sometimes R and Rc are jumpered together at the premises thermostat and are connected to the HVAC system with a single common wire This is the case if both heating and air conditioning are controlled by the same control System Theremaining three wires connect the thermostat to the heating cooling and fan control loop inputs of the HVAC system Under the correct circumstances switches in the thermostat connect the applicable power connection R or Rc to the applicable control loop of the HVAC system turning it on For example if the thermostat is set to turn the heat on when 65 degrees is reached the relay contacts between the power connection R
16. e sure there is only low voltage typically 24VAC on all control wiring of the heating and cooling system before starting the installation Only qualified personnel shall test the voltage to prevent a shock hazard 4500 Installation Instructions 4500 Specifications 1 2 Air Conditioner Compressor Off Cycle Physical Dimensions Control loop rating each SECTION 2 Front Panel Controls In This Section Description Description Referring to Figure 1 below there are two controls and one status indicator on the front panel of the thermostat HEAT lt gt COOL BYPASS lt gt ACTIVE Figure 1 Front Panel Controls 1 HEAT COOL Switch This switch is used to set the control mode of the 4500 thermostat The mode can be set to either heat or cool This is the same as found on most thermostats For premises that only have heat or air conditioning but not both the proper mode should be selected with this switch and the setting should not be changed 2 ACTIVE BYPASS Switch This switch is used to select the thermostat that will control the HVAC system the premises thermostat or the 4500 When this switch Is set to the ACTIVE mode the 4500 is enabled and can set back the premises temperature when the security system is ARMED AWAY BYPASS is used to bypass the 4500 completely and use the pre existing thermostat at all times 4500 Thermostat Installation nstructi ons 2 2 You will not be able to adjust room
17. e terminals of the 4500 Refer to the following table for proper connection information Table 1 Lead from HVAC Terminal on system 4500 Fan green G Coo yellow v Heat 6 6 Connect a wire to each of the vacant terminals on the premises thermostat that you noted in step 4 above and make a run from those terminals to the 4500 Note that HVAC industry standard color codes and abbreviations are noted here but these colors may not have been used in the original installation 7 Connect the three wires installed in step 6 from the premises thermostat to the 4500 referring to the following table for proper connection information Table 2 Terminal on existing Terminal on thermostat 4500 Cv 4 8 Verify that the following jumper wires are in place on the 4500 terminal strip Replace if missing Table 3 From 4500 To 4500 Terminal Terminal 3 6 Section 3 Installing the 4500 Thermostat 9 Connect the 4500 to the 4286 phone module using the supplied keypad type cable The cable contains four wires of different colors which are connected to the 4500 as indicated in the following table Table 4 Wire from 4286 Terminal on cable 4500 Green NN NE Rd 10 f two 4500 thermostats are used connect them in parallel by running another set of wires from the first 4500 to the second 4500 using the same terminals as shown in Table 4 above Connections from 4286 Phone Module to
18. ees above and below room temperature Note that it takes at least five minutes for the air conditioner to turn on from the time it turns off This feature is present in the 4500 to protect the air conditioner compressor from excessive cycling 8 Switch the ACTIVE BYPASS slide switch to BYPASS Check the cool mode of the premises thermostat by turning the air conditioner on and off by varying its set point above and below ambient temperature 9 If there are two 4500 s in the system test the operation of the second 4500 by repeating the testing steps 1 8 above The LOG ON thermostat setting menu selection 2 key is used to choose the second thermostat so it can beset After testing the 4500 s and premises thermostats set them to temperatures as desired by the homeowner Setting the Premises Thermostat The 4500 can decrease the amount of heat or air conditioning that would be provided by the premises thermostat but cannot increase it The premises thermostat should always be set to a higher heat set point and a lower cool set point than the 4500 set back temperature Then the 4500 will be able to set back the temperature and it will adjust room temperature to the set back level when the security system is armed away If the premises thermostat is set to provide less heat or air conditioning than the 4500 set back temperature the 4500 will remain passive at all times and the premises thermostat settings will prevail Setting the 4500 T
19. enerals verbo ta RO E 6 1 Typical Thermostat Set Up eenn 6 1 Appendices FGC Part I5 Statements conr nier eta o ure ae Dec SE dann A 1 Ademco Limited Warranty nnne nnn nnn nnn nnns A 2 summary Of Connections dineert ERR ERR Sax C TIE FOR anes A 3 SECTION 1 General Description In This Section Application and Description 4500 Specifications Application and Description The Ademco 4500 thermostat provides control for both heat and air conditioning The Ademco 4286 Phone Module is required in the installation for use with the 4500 thermostat The user sets the 4500 thermostat using any Touch tone phone either on premises or remotely The 4500 is not a replacement for the existing thermostat which remains in the installation The 4500 can be user selected to provide remote control and set back functions In summary the ADEMCO thermostat allows the user to e Set back the temperature to that set in the ADEMCO thermostat automatically by arming in the AWAY mode when leaving home e Resume normal temperature as set by the existing thermostat automatically by disarming the system when returning home e Check the present temperature by phoning in from a remote location The Ademco 4500 Thermostat cannot be used on 110 volt control lines To prevent a shock or fire hazard mak
20. existi ng thermostat at the premises The user can then switch between the 4500 and the existing thermostat using the ACTIVE BYPASS switch previously described The 4500 can be used in most applications where ordinary low voltage thermostats are used t cannot be used for control of electric heat pumps or line voltage systems with 110VAC control lines Line voltage systems can be converted to low voltage systems with the addition of a 24 volt transformer and a relay to control the 110 volt power These components are available from home supply stores and other suppliers of heating system components Conversion of a 110VAC system to a 24VAC system requires a licensed electrician 4500 Thermostat Installation Instructions While installation of the 4500 is possible without the services of a HVAC contractor some installers will prefer to have an HVAC contractor connect the 4500 to the HVAC system and test its operation This is recommended if you do not have HVAC experience n cases where you prefer to do the entire installation it is suggested that the HVAC contractor be contacted for information on the type of heating system and the amount of span i e temperature swing that should be set with the 4286 phone module Mounting and Installation The 4500 thermostat is designed to be mounted alongside the existing thermostat Once the 4500 is mounted the wiring connections can be made The wires tothe existing thermostat will have to
21. hermostat To enter and use the 4286 thermostat programming mode 1 There must be at least one thermostat programmed into the system by way of the 4286 installer programming mode entry 5 2 4 Section 5 Testing the4500 With the 4286 PhoneM odule Obtain phone access from the phone module Enter the 2 digit phone code Enter the 4 digit system code if prompted Press 99 on the phone keypad after the complete status announcement The 4286 will announce Thermostat Mode The temperature setting for thermostat 1 will follow You can change its set point using menu selection 1 below If thermostat 1 is in BYPASS or CHECK that status will be announced instead of the set point The 4286 will also announce whether set back has been turned off by the user Menu Selections change temperature enter 1 This selection is used to set the armed away set back temperature for thermostats 1 or 2 This menu selection will NOT be announced if the thermostat is in CHECK or BYPASSED To allow the user to change the ARMED AWAY set back temperature settings the 4286 will announce the present setting in effect and wait for a new 2 digit temperature setting to be entered If the current temperature setting is acceptable to the user the user may press the key to advance without changing the setting If the number entered is outside the allowed range 45 to 99 F 07 to 37 C a buzzer will sound from the phone and
22. ield 07 as 000 Field 08 as 015 and Field 09 as 158 Field 07 Thermostat 1 Descriptor 1 NEN default value 0 0 0 no announcement default Field 08 Thermostat 1 Descriptor 2 default value 0 0 0 2no announcement default Field 09 Thermostat 1 Descriptor 3 NEN default value 0 0 no announcement default Field 10 Thermostat 2 Enable and Address 00 thermostat 2 disabled not in the system default 02 set address to 02 Field 11 Thermostat 2 Swing NN digit 1 Swing above set point digit l 2 digit 2 Swing below set point This field defines how many degrees below the set point the heat will turn on and how many degrees above the set point the heat will turn off These values also define the swing of the air conditioner operation This option is also known by HVAC Heating Ventilation Air Conditioning installers as temperature span or hysteresis t is recommended that the premises HVAC installer be consulted to choose the values to be programmed for optimal HVAC system efficiency Section 4 Programming the 4286 to Add T hermostat s Thefirst digit indicates the swing above the set point the second digit indicates the swing below the set point as indicated below Temperature Span Swing ABOVE BELOW 0 0 deg F 0 0 deg 1 2 0 0 deg F 0 0 deg C 2 40 5 deg F 0 3 deg 2 0 5 deg F 0 3 deg 3 40 75 deg F 0 4 deg 0 75 deg F 0
23. ly or indirectly for any loss or damage arising under this Limited Warranty or otherwise regardless of cause or origin Seller s maximum liability shall not in any case exceed the purchase price of the product which shall be the complete and exclusive remedy against Seller This warranty replaces any previous warranties and is the only warranty made by Seller on this product No increase or alteration written or verbal of the obligations of this Limited Warranty is authorized Appendices Heat TO HVAC Fan SYSTEM TO PREMISES Cool THERMOSTAT Heat Green Hed Two jumper wires are factory installed Black TO 4286 between screw terminals 1 3 and 2 4 VOICE MODULE Replace if missing Yellow r DIP 1 SWITCH 1 2 3 0 5 6 C2 8 9 0 0 9 12 SHOWN SET FAN bod 4 CONTROL PINS TEMPERATURE SENSOR JUMPER PLACED ON 1 and 2 FAN ON WITH HEAT AND COOL JUMPER PLACED ON 2 and 3 FAN ON WITH COOL ONLY 4500 Thermostat Summary of Connections A 3 ADEMCO GROUP 165 Eileen Way Syosset New York 11791 Copyright 1997 PITTWAY CORPORATION N7970 7 97
24. ment default Field 14 Thermostat 2 Descriptor 2 Default value 0 0 0 announcement default Field 15 Thermostat 2 Descriptor 3 E 4 8 Default value 0 0 0 announcement default This completes the programming of the 4500 Once all necessary fields have been programmed hang up the phone If you want to reenter the 4286 Programming Mode after exiting you will have 15 minutes to do so using the procedure beginning on page 4 2 of this manual The 15 minute time limit is to prevent the user from accidentally entering programming mode If more than 15 minutes have passed you must reset the system by removing the 12VDC power temporarily from the 4286 by disconnecting the keyed header that connects it to the control panel located near the 2 relays Wait at least 5 seconds then reconnect the keyed header and follow the procedure To Enter and Use the 4286 Programming Mode on page 4 2 of this manual WORD INDEX WORD 116 255 067 117 161 118 119 AIR ALARM AND APARTMENT APPLIANCE AREA ATTIC BABY BACK BAR BASEMENT BATHROOM BATTERY BED BEDROOM BLOWER BOILER BRIGHT BUILDING BURGLARY 120 121 122 021 051 CALL CENTRAL CHIME CLOSED COMPUTER DAUGHTER S DEN DETECTOR DEVICE DIM DINING DOOR DOWN WORD INDEX 184 130 131 132 133 004 134 211 135 040 029 137 087 Section 4 Programming the 4286 to Add T hermostat s THERMOSTAT VOICE DESCRIPTO
25. mming field OO N ew data may be entered into each field oncethe field contents are announced Once accepted the new data will be echoed back with an announcement If an erroneous entry is detected a buzzer sound will be heard in the receiver and the current field and data will be repeated If you wish to change the data again reenter it after the echoed announcement Once you are satisfied with a field entry press to go on to the next field If you want to go back one field press Pressing after Field 15 will return you to Field 00 Likewise pressing at Field 00 will put you back to Field 15 f you do not need to program all fields such as to modify a program already entered press on the phone keypad to advance by one field each time until desired field number is announced For example pressing will advance the field from 00 to Programming Fields The following programming fields need to be programmed as described in previous steps 1 thru 3 System default settings are indicated by default following an entry Field 00 Monitored Keypad Address EN This field enables or disables the 4500 thermostat AND speaker output features and selects which keypad to monitor an entry based on the following chart Section 4 Programming the 4286 to Add T hermostat s If Non Select MUTE The System Addressable Addressable 4286 97 Mode Contains Comments Thermostat 01 30 Assign 4500 to same
26. ostat printed circuit board 3 8 Section 3 Installing the 4500 Thermostat Setting the Fan Control Pins Thethree fan control pins in the center of the 4500 are used to control the operation of the HVAC system s fan Using the jumper provided you can select whether or not the system s fan should turn on with cooling and heating or turn on only with cooling The operation of the fan depends upon which two pins the jumper is installed on If you want the fan to turn on with cooling only place the jumper provided between pins 2 and 3 If you want the fan to turn on for both heating and cooling place the jumper between pins 1 and 2 PLACE THIS JUMPER ON FAN CONTROL PINS SHOWN SET TO 01 OQOOOOOOOOOO xk PINS JUMPER PLACED ON 1 and 2 FAN ON WITH HEAT AND COOL JUMPER PLACED ON 2 and 3 FAN ON WITH COOL ONLY After installation has been completed replace the cover of the 4500 thermostat reapply primary power to the system and continue thermostat set up in Section 4 Phone announcements during the first minute of application of primary power to the system or after exiting 4286 installer programming mode will yield temperature 00 zero zero This is perfectly normal Once the system has reset itself correct messages will be annunciated as called for in the programming of the thermostat 3 9 4500 Thermostat Installation nstructi ons 3 10 SECTION 4 Programming the 42
27. rol have the G connection Air conditioning systems have Rc and Y connections as well as a G connection for the fan Combination heat and air conditioning systems usually will have all connections shown Sometimes and Rc are common and are jumpered together at the premises thermostat This is the case if both heating and air conditioning are controlled by the same control system Step by Step Installation Instructions Toinstall the 4500 thermostat follow the procedure below 1 Asshould be done when working on any electrical equipment remove primary power to the system to prevent damage to the equipment 2 Open the front panel of the 4500 so that you can access its terminal strip Mount the 4500 as near to the premises thermostat as possi ble 4 Makea note of the terminal number that the Y ellow G reen and W hite wires are connected to on the existing thermostat Y ou will need to connect new wires to these terminals later Tag and disconnect those wires from the premises thermostat as follows e White W Heat connection e Yellow Y Cool connection e Green Fan connection These three wires removed come from the HVAC system refer to Figure 2 and will be connected to the new 4500 thermostat t may be necessary to splice these wires in order to reach the terminals of the 4500 3 5 4500 Thermostat Installation Instructions 5 Connect the tagged wires removed in step 4 from the HVAC system to the applicabl
28. security system is armed in the away state 2 security system to the ARMED AWAY state Y ou are about to perform a test of the 4500 thermostat set back operation 3 Ifthe 4500 will control a heating system set the 4500 front panel slide switches to ACTIVE and HEAT Set the premises thermostat into its heat mode as well If only air conditioning will be controlled skip to step 6 4 Perform the following test Set the set points according to the steps described in Setting the Premises and 4500 Thermostat sections that follow Set the premises thermostat 10 degrees higher than room temperature Set the 4500 set point to a temperature 5 degrees lower than the room temperature The heat should turn off within one minute Set the 4500 set point to a temperature 5 degrees higher than room temperature The heat should turn on within one minute 4500 Thermostat Installation Instructions 5 Check the heat mode operation of the premises thermostat by varying its set point and verifying that the heating system turns on and off 6 Ifthe 4500 thermostat will control an air conditioning system set the 4500 front panel slide switches to ACTIVE and COOL Set the premises thermostat into its cool mode as well If only heating will be controlled skip to step 9 7 Set the premises thermostat 10 degrees below the present room temperature Similar to step 4 above turn the air conditioner off and then on varying the 4500 set point 5 degr
29. temperature by phone when the 4500 is bypassed There are several uses for the BYPASS switch function e Allows the user to go back to their pre existing thermostat at any time e Allows heating air conditioning service people to bypass the 4500 during HVAC servicing and maintenance The 4500 is out of the HVAC control circuit when bypassed e Allows switching back to the pre existing thermostat if the security system is not working or is being serviced 3 ACTIVE BYPASS Indicator This LED indicates the status of the 4500 When the ACTIVE BYPASS switch is in the ACTIVE position the LED will be continuously on When in BYPASS the LED will be continuously off If the 4500 has lost connection with the 4286 phone module the LED will flash indicating 4500 connections DIP switch address settings and 4286 installer programming entries should be checked SECTION 3 installing the 4500 Thermostat In This Section General Mounting and Installation Wiring Connections Step by Step Installation Instructions Seting the DIP Switch Setting the Fan Control Pins General Information The 4500 is controlled by a four wire interface from the 4286 VIP Module and is powered by 12VDC auxiliary power from the 4286 which in turn is powered by the control panel The 4500 has separate loops for heat cool and fan which connect to the existing home HVAC system wiring There are up to five wires that connect the 4500 to the
30. the temperature setting repeated This will continue until the number entered is within the allowable range If the 4500 is BYPASSed the user must switch the ACTIVE BYPASS slide switch on the 4500 front panel to the ACTIVE position which will then allow access through the 4286 thermostat menus 4500 Thermostat Installation Instructions 5 4 For set back on off enter 3 Turning off set back will result in it remaining disabled while armed away until the next time the system is disarmed This feature allows the user to turn off the set back before returning home so that the premises will have time to return to a comfortable at home temperature It also allows the user to turn off set back before leaving home when they plan to be away only a short time The user can alsoturn the set back on again with this menu selection if they have a change of plans Tolog on enter 2 This selection is announced if more than one thermostat has been programmed into the system It allows the user to select thermostat 1 or 2 for setting The user can set the 4500 just selected with the to change temperature enter 1 menu selection exit enter 0 This selection exits the thermostat mode If a 4500 thermostat does not respond to the 4286 phone module for two minutes the phone module will announce Check thermostat 1 2 Descriptor instead of the temperature If the temperature falls below 37 F 3 C the 4286