Home

User`s Manual

image

Contents

1. __s Single Pump Controller MODEL S L1302A When using electrical equipment basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read and follow all instructions before using the equipment Keep the cord out of heavy traffic area To avoid fire hazard NEVER put the cord under rugs near heat generating devices Always unplug power before servicing Do not drop or insert any object into any openings Do not operate any equipment with a damaged part Any other use not recommended by the manufacturer may result in electrical shock or injury to persons Never use outdoors Do not attempt to repair or adjust any electrical or mechanical functions on this unit Doing so will void the warranty oe ee After reading this owner s guide if you have any questions or comments please call 1 817 633 1080 or contact our technical support department at support luraco com or visit our website at www luraco com for more information PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS FEATURES OPERATIONS LURACO Simple Pump Blower Control This system allows the bather to operate a pump or other high power with the touch of a single button Other features l II Controls 120V or 240V devices up to 14A Digital and Analog control options One extra outlet for LED light Compact Design Built in timer UL Approved lf the
2. CO Technologies Right to make changes LURACO Technologies reserves the right to make changes to the product and information published in this document including without limitation specifications and product descriptions at any time and without notice This document supersedes and replaces all information supplied prior to the publication hereof Suitability for use LURACO Technologies products are not designed authorized or warranted to be suitable for use in life support life critical or safety critical systems or equipment nor in applications where failure or malfunction of an LURACO Technologies product can reasonably be expected to result in personal injury death or severe property or environmental damage THANK YOU FOR BUYING LURACO TECHNOLOGIES PRODUCTS LURACO TECHNOLOGIES INC 1132 107 STREET ARLINGTON TX 76011 TEL 1 817 633 1080 FAX 1 817 633 1085 WWW LURACO COM
3. ge in shipping 2 Before packing your unit be sure to enclose e Your name with full shipping address and telephone number e Adated receipt as PROOF OF PURCHASE e Attach a paper detailing the problem you are having 3 SIMPLE PUMP CONTROLLER SPECIFICATIONS e Ratings Max L1302A Motor up to 14 Amp Light 1 Amp e Voltage 120VAC or 240VAC e Frequency 60Hz e Dimensions L 4 9in W 2 5in H 3 9in e Weight 3Lbs Disclaimers Limited warranty and liability Information in this document is believed to be accurate and reliable However LURACO Technologies does not give any representations or warranties expressed or implied as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information In no event shall LURACO Technologies be liable for any indirect incidental punitive special or consequential damages including without limitation lost profits lost savings business interruption costs related to the removal or replacement of any products or rework charges whether or not such damages are based on tort including negligence warranty breach of contract or any other legal theory Notwithstanding any damages that customer might incur for any reason whatsoever LURACO Technologies aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of LURA
4. to be installed Note The electrodes can be installed in vertical or horizontal configuration Fig 2b a Drill two holes 9 64in diameter on the tub with approximate distance as shown in Fig 2b above Insert the electrodes and tighten the nuts to secure the ring connectors as shown in Fig 2a above b Connect the other end of sensor cable to the port named Level Sensor c Connect the control button to the port named Control Button d Connect the Light transformer to the port named Light Note The maximum current this port can provide is 1 A e Connect the motor to the port named Motor WARRANTY INFORMATION One 1 YEAR LIMITED WARRANTY 1 This Warranty applies only to the original purchaser of this product 2 This Warranty applies ONLY to repair or replacement of any supplied or manufactured parts of this product The warranty does not cover normal wear coating dropped or abused unit 3 Unless otherwise proscribed by law The LURACO technologies Inc shall not be liable for any personal injury property or any incidental or consequential damages of any kind resulting from malfunctions defects misuse by improper installation or alteration of this product Attention Any modification to the product will void the warranty Important Instructions If you need to send a unit to us for repair please follow the steps below 1 Carefully pack the item in its original carton or other suitable box to avoid dama
5. water sensor is installed motor will not be turned on until water level is above the sensor electrodes Note There is a 10 second turn off delay when water level goes below sensor INSTALLATION GUIDE Overall System Integration LIGHT LIGHT Simple Pump Control TRANSFORMER MOTOR JUMPER cr Analog Port Th KEYPAD Digital Port WHITE NEUTRAL ELECTRICAL FEEDER OUTLET BLACK LINE D 120V 240V 20A GREENGROUND Q WALOUNET Fig 1 Wiring Connection Diagram Installation Guide for the Water Level Sensor Two conductive electrodes with advanced electronics and firmware are used to detect the water level This is the same water level sensing technology that has been widely used in Bathtubs and Whirlpool tubs This technology can work with any non metallic spa tub materials such as fiber glass clear fiber glass acrylic and even glass A sensor proper installation is required Important Note if your tub is painted with metallic particles filled paint you need to remove the paint surrounding the electrodes in order for the sensor to operate properly Electrode 1 23in max o8in Max in Max Electrode 1 Electrode 2 Electrode 2 Vertical Configuration Horizontal Configuration a b Fig 2 a Electrode mounting behind the tub b Electrode Configurations Follow the steps below for the water level sensor installation Locate the location for the sensor electrodes

Download Pdf Manuals

image

Related Search

Related Contents

www.philips.com/welcome  TDSHーBA 東芝ワイヤレスマイクロホン取扱説明書  Parti de son plein gré ou limogé    Ferro de Soldar Portátil a Bateria Manual de Instruções  Epson AcuLaser C3000 User's Manual  CineMate® 220 home theater system  MODE D`EMPLOI ENREGISTREMENT DE MAGASINS  R/C MINI-HELIKOPTER  Page 1 _ B 0 m _ Turm 256 HC tower le mât max EB 0 m Evil: ` E2  