Home
User Manual
Contents
1. The Netherlands T 31 105112911 F 31 105115114 info tradinco com www tradinco com Tradinco Instruments India Pvt Ltd Plot No2 Suyog Co Op Hsg Society Cross Gokhale Road Shivaji Nagar Pune 411 016 India info tradinco com www tradinco com 2 1 Hazard signs and other symbols used WARNING CAUTION Risk of injury This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property CAUTION Crushing hazard This sign indicates dangers which could result in the crushing of fingers or hands CAUTION Risk of injury in the case of excessive pressure This sign indicates dangers which could arise from excessive pressure in a piece of equipment CAUTION Material damage This sign indicates actions which could lead to possible damage to material or environmental damage ADHERE TO OPERATING MANUAL X NOTICE A _ This symbol indicates important notices tips or information A Pay attention to and comply with C Check the specified points or notices information that is marked with this Reference to another section symbol document or source Follow the specified instructions and e Item steps Adhere to the given order ax TRAQC 5 P700 07 2014 E page 4 v Tradinco y User Manual TRAQC 5 PE eaan P700 3 Device description Test item The hand pump creates positive pressure for at R fer nc the inspection adj
2. any defect failure or damage caused by Improper use of the instrument Normal wear of the product Modification or repair carried out by or on behalf of the owner or by a third party Implementation of modifications to the product that are not supplied or implemented by TRADINCO INSTRUMENTS aoo TRADINCO INSTRUMENTS and its vendors will not be liable for any indirect special incidental or consequential damages irrespective of whether TRADINCO INSTRUMENTS or the vendor has advance notice of the possibility of such damages The type number of the product as listed on the instrument tag plate should always be mentioned in any correspondence concerning the product TRADINCO INSTRUMENTS Industrieweg 74 Postbus 37 2650 AA Berkel en Rodenrijs The Netherlands 31 0 10 5112911 www tradinco com info tradinco com TRAQC 5 P700 07 2014 E page 3 v Tradinco w User Manual TRAQC 5 icisitani eR P700 2 About this operating manual e The operating manual is aimed at specialists and semi skilled personnel e Before each step read through the relevant advice carefully and keep to the specified order e Thoroughly read and understand the information in the section Safety Instructions If you have any problems or questions please contact your supplier or contact us directly at Cae Tradinco Instruments The Calibration Company Tradinco Instruments Postbus 37 2650 AA Berkel en Rodenrijs
3. screw the MINIMESS adapter on the pressure hose 10 Select the suitable adapters and seals for the test item s connection 11 Screw the adapter for the test sample onto the MINIMESS adapter 12 Turn the test sample with seal in the adapter IMPORTANT Do not yet tighten the test item 13 Now pump until the hydraulic liquid escapes at the test sample s connection The pressure hose and the test sample connection are now ventilated CAUTION Demineralised water LZ During the quality inspection of the TRAQC 5 P700 a functional test is u gt carried out with demineralised water The reservoir may therefore contain residues of this liquid Check the compatibility with your application and remove the residue using appropriate measures e g rinsing out with the hydraulic liquid TRAQC 5 P700 07 2014 E page 13 sz Tradinco s User Manual TRAQC 5 P epas P700 7 Handling Adhere to the following safety instructions when operating the hand pump CAUTION Crushing hazard A During the pumping procedure ensure that fingers or other body parts are kept away from the area between the hand grips and the piston rod CAUTION Material damage to valve stop AN If put under too much strain the stop and the hand pump will be damaged Only continue to tighten the valves the fine adjustment and pressure relief valves by hand once the stop has been reached Before creating pressure consider Befor
4. TRAQC 5 P700 Hydraulic Hand Pump User Manual sz Tradinco s User Manual TRAQC 5 Instruments P700 The Calibration Company Contents 1 Warranty srein eaeeee cadences devel a DaT EE e EREDE R OEP eens Gates Dre bea uede a8 3 2 About this operating Manual cceceee eee ee ee eee eee teens eaea 4 2 1 Hazard signs and other symbols used cceceee eset eee e eee ee etna teens eaeees 4 3 Device description essssssesseeseeeeenn nennen nean seas sea sea sea sea nnn nn nn 5 3 1 Type plate and label erecto ocn eren e e rz ees 5 3 2 Scope of delivery and accessories essssssssessseememee 5 3 3 Accessories optional sssssessssrssrassssrrsnnnesnsrnnnnasnsennannasnserrnnnaennernnn 6 3 4 Intended USE rre zv ruv ecu ag a DY OP NR CS VAT RU Y RN VER IV IN EFT ETE DS 6 3 5 Exclusionsor lability cre eere Ee a n EX EOS e ERAT ex 7 4 Safety instr ctiOns iei eee x denen tena X EXE ARX KRAERERELERERE QUERER RAALE NER EEER NE AMA 8 4 1 Qualified personnel ores ceiose ne ere errare hrec nec a 8 4 2 General safety instructions cesses nnne nnne nnn nnn 8 4 3 Special safety instructions ssssssssssssesssseeeme memes 9 5 Construction and function cecec eee e teeter nennen mene 10 5 1 eines ea a a E E 10 5 2 Important notes on pressure fluctuations cece eee ee test ee eeeeeeeeneeneeas 11 6 Commissioning with ventilation cceceeeee
5. as accessories A Non pressurised storage Only store the hand pump with the pressure relief valve open This ensures that no pressure can be built up by unintentional pumping movements ax TRAQC 5 P700 07 2014 E page 8 Tradinco 9 User Manual TRAQC 5 ka ue ss P700 A Avoid external force of all kinds towards the hand pump and its operating elements A Do not use the hand pump if it is damaged or defective 4 3 Special safety instructions Warnings that are specifically relevant to individual operating procedures or activities can be found at the beginning of the relevant sections of this operating manual TRAQC 5 P700 07 2014 E page 9 Tradincoy User Manual TRAQC 5 ciliated P700 The Calibration Company 5 Construction and function Connections MINIMESS connection pressure hose Connector reference gauge Operating elements Fine adjustment valve hand wheel Pressure relief valve rotary knob OG Seal reservoir with safety valve Hand grips Main components Upper and lower pump body Reservoir with suction and relief outlets Piston rod with internal spring 9 Pressure hose with MINIMESS connection 5 1 Function The reference and the test sample or the pressure device to be tested hereafter test sample are connected to the hand pump Pumping is carried out by repeatedly pushing the hand grips together An internal spring returns the hand gr
6. ccessories Pressure hose Replacement pressure hose with l seals Consumables Hydraulic oil Demineralised water TRAQC 5 P700 07 2014 E page 23 r Tradinco TE Instruments The Calibration Company TRADINCO INSTRUMENTS Industrieweg 74 Postbus 37 2650 AA Berkel en Rodenrijs The Netherlands 31 0 10 5112911 www tradinco com info tradinco com TRAQC 5 P700 07 2014 E User Manual TRAQC 5 P700 page 24
7. d pump consists of various different materials It should not be disposed of with household waste Take the hand pump to your local EY recycling plant T or S Send the hand pump back to your supplier or to TRADINCO X TRAQC 5 P700 07 2014 E page 22 Tradinco v User Manual TRAQC 5 Instruments P700 The Calibration Company 11 Technical data and accessoires Type TRAQC 5 P700 Pump with hose Pressure range Positive pressure 700 bar Medium Hydraulic oil Demineralised water Temperature range 10 60 C not freezing 1 Connection Reference G a Pressure hose MINIMESS 1620 Test item Pressure hose 1 m with MINIMESS 1620 or with MINIMESS adapter 1620 to G a4 Dimensions 255 x 225 x 85 mm Weight 1 7 kg 1 Observe the instructions on the manufacturer s data sheet for the hydraulic oil that is used Accessories MINIMESS MINIMESS 1620 auf G 4 adapter Adapter set G G GR G 2 NPT Ve NPT NPT 2 M12x1 5 M20x1 5 GA GWA Seal set Flat seals made of plastic a and O rings 0 Transportation l Lid Burl foam with document compartment Main compartment Tight fitting rigid foam inlay for pump and accessories r Illustration exam Eo a ple Dimensions _ _ v 450 x 370 x 125 mm Complete set with reference D2 Weight with pump 4 8 kg and a
8. e you create pressure with the hand pump you should check for the following requirements e The reference gauge is connected to the hand pump e The test item is joined to the pressure hose with the correct adapters and seals e All pressure connections are correctly in place so that they resist pressure e The hand pump the pressure hose and the test sample have been properly ventilated gt 6 7 1 Generating pressure After the commissioning with ventilation pressure can be created with the hand pump With increasing back pressure in the system the pumping process becomes more and more difficult WARNING There is a risk of injury if the maximum pressure is exceeded A Note the maximum permitted pressures of the individual components in the measurement device If the limit values are exceeded it may lead to material damage and injuries Do not continue to pump under any circumstances if the maximum permitted pressure has been reached or an exceeded measuring range is displayed CAUTION Material damage to test item AN Adhere to the maximum pressure of the test item Only create an admission pressure with the hand grips that is lesser than the necessary testing pressure Following this carefully increase the pressure using the fine adjustment valve TRAQC 5 P700 07 2014 E page 14 Tradincoy User Manual TRAQC 5 Instruments P700 The Calibration Company 7 2 Notes on operation Plea
9. easily using with the palm of the hand ax TRAQC 5 P700 07 2014 E page 16 Tradincoy User Manual TRAQC 5 Instruments P700 The Calibration Company 7 5 Pressure measurements For adjustments calibrations or an inspection of accuracy it is vital that the test item and the reference have the same pressure The pressure needed for the test points is built up and adjusted with the hand pump gt 7 1 Wait for pressure stabilisation AZ After changes in the pressure it takes a few minutes for the pressure in the _ measurement device to stabilise 8 5 2 Wait approximately 3 5 min before you begin taking measurements The necessary procedures for measuring pressure are configured by the operator Carrying out the pressure measurements e Carry out the necessary tests and measurements e Document your results 7 6 Releasing pressure Once the pressure measurements have been completed the positive pressure in the hand pump the test item and in the pressure hose need to be brought into balance CAUTION Risk of injury through excessive pressure Do not remove any connected components test item pressure hose reference gauge if the hand pump is under pressure Hold the hand pump so that no liquid is present at the cap of the reservoir Otherwise liquid may be forced out through the safety valve in the cap Releasing pressure Turn the pressure relief valve knob 2 3 rotations in a
10. eee eee eee ee eee nent eee eee ene ees 12 7 E ineiliarc M vtaaetepieeta tea EP E nese E G 14 7 1 Generating pressUle ixcuecesi exse Sc iexlrek xen skR NE EN RE NEU ENENCO EROR NES ROLE SE 14 7 2 Notes on operatlonii ieece nt eer eae nre xRI X RYE e exc iar vied UY RR E KR a Rn E A 15 7 3 Hand pump operation ssssssssesseseeenenee nemen memes nnn nnn 16 7 4 Increasing pressure with the fine adjustment valve sssus 16 7 5 Pressure measurements noct reee tmr mtr exe ERN AERE E UP RR E veces RN HR 17 7 6 Releasing pressure ceo renci bets ori pekerrexbrba iie Deer a exe Deve ee tinned eias 17 8 PRODIGIMS RERO EE ELS LI TTE 19 9 Maintenance cleaning storage and transportation eseeseeees 20 9 1 ullis EUMETETITIMMIMT 20 9 2 Cleaning cu et xe nex E HERREAKROTERKIREAIERDIAAER RECEN DARAN ARE RERER ER RIA NTER LINER 20 9 3 Storage and transportation ccceceee cece eee eee eee tees eens tees tees nana 20 10 DISPOSAl acct mM 22 11 Technical data and accessoires sssssesseseeeeee nennen nnn 23 TRAQC 5 P700 07 2014 E page 2 v Tradinco w User Manual TRAQC 5 PHI rre P700 1 Warranty During the design and manufacturing of this instrument the at most attention has been given to quality and durability This manual contains information needed for the safe and effective use of the capabilities of the instrument Please read the manual carefully before o
11. facturer s product documents 9 2 Cleaning Clean the hand pump with a dry or slightly damp lint free cloth Do not use sharp objects or aggressive cleaning agents to clean the pump Avoid contact with aggressive media 9 3 Storage and transportation For storage and transportation we recommend our transportation case which is available as an accessory The tight fitting rigid foam inlay offers optimum protection for the hand pump with pressure hose and accessories Z REFERENCE GAUGE The common reference models fit into the gaps in the transportation case i and do not need to be removed Before storage we recommend that you consider the following points e Clean the hand pump and the accessories e Turn the fine adjustment valve in a clockwise direction until the thread is no longer visible gt illustration e Open the pressure relief valve TRAQC 5 P700 07 2014 E page 20 v Tradinco y User Manual TRAQC 5 Ts P700 Important storage information e Do not store under pressure AL Only store the hand pump with the pressure relief valve open This ensures E that no pressure can be built up by unintentional pumping movements e Openings facing up Ensure that the caps of the supply container and the refill bottle are properly closed and facing up when these items are stored TRAQC 5 P700 07 2014 E page 21 m Tradinco y User Manual TRAQC 5 PEI organe P700 10 Disposal The han
12. for all common pressure connections with or without pins e Seal set The seal set contains flat seals made of plastic and O rings for all common pressure connections e Replacement pressure hose with seals The pressure hose is available separately as a replacement part with the necessary seals 3 4 Intended use The TRAQC 5 P700 hand pump can only be used for generating pressure in low volume measuring devices The device is only designed for use with hydraulic oil or demineralised water other media will result in damage to the hand pump The hand pump may not be attached to external pressure sources WARNING No safety component The hand pump of the series TRAQC 5 P700 is not safety component in accordance with Directive 2006 42 EC Machine Directive Never use the TRAQC 5 P700 as a safety component The operational safety of the device supplied is only guaranteed by intended use The specified limits gt 11 Technical data may under no circumstances be exceeded TRAQC 5 P700 07 2014 E page 6 v Tradinco w User Manual TRAQC 5 Instruments P700 The Calibration Company CAUTION Risk of injury or material damage By connecting the TRAQC 5 P700 the measuring device is hydraulically connected to the hand pump If the pressure relief valve is opened a A compressed medium can flow through the pressure hose into the hand pump s storage container At sufficiently large volumes the reserv
13. ips to their start position The pumping movements are transferred to the pistons in the pump body via the push rods The hydraulic liquid is then suctioned from the storage container and pressed through valves to the test item In the case of correct ventilation this quickly leads to an increase in pressure The construction of the hand pump means that the same pressure is generated for the test item as for the reference test gauge The pressure is set to the necessary value using the fine adjustment valve With the pressure relief valve the pressure can be relieved into the reservoir For the assessment of the test sample the pressure displayed on the reference manometer is compared with the measurement value P tranc S TRAQC 5 P700 07 2014 E page 10 v Tradinco w User Manual TRAQC 5 THIS erre P700 5 2 Important notes on pressure fluctuations It is completely normal that the pressure is not constant from the start In the event of changes to the pressure in the measurement device it always lasts a few minutes until the pressure stabilises This is influenced by a variety of factors The most important influence factors are Poor ventilation If there is still air in the measurement device the pressure build up lasts significantly longer Moreover there is a fall off in pressure over a limited period due to diffusion processes Mechanical characteristics of the pressure hose Bending or rolling up the pre
14. le Pumping stroke stiff TRAQC 5 P700 07 2014 E Defective incorrect seal Seal incorrectly positioned Pressure relief valve open Air was sucked in during pressure generation Leakage in the test item High counter pressure in the test item Check seal size material wear Check positioning of seal Close pressure relief valve Open pressure relief valve so that the air can be rinsed out of the piston system Ensure the correct position of the hand pump during pressure generation Check connections Check positioning of seals Increase the pressure with the hand wheel of the fine adjustment valve page 19 v Tradinco X User Manual TRAQC 5 Instruments The Calibration Company I 700 9 Maintenance cleaning storage and transportation 9 1 Maintenance No maintenance is required for the hand pump and it cannot be repaired by the operator either In the case of a defect the appliance must be sent back to the manufacturer for repair Check the seals and O rings for fractures and wear before use Replace defective or worn seals and O rings Visually inspect the TRAQC 5 P700 and its components for damage The inspection interval depends on the frequency of use but at least once a year RECOMMENDATION E i _ Do not use gaskets seals and hydraulic hoses made from rubber silicone or A fs plastic longer than 6 years Observe the corresponding instructions in the manu
15. n anti clockwise direction and wait until there is no longer any positive pressure Remove the test item with adapters and seals from the pressure hose Put the hand pump away along with any accessories which have been used gt 8 9 Maintenance cleaning storage and transportation TRAQC 5 P700 07 2014 E page 17 z Tradinco y User Manual TRAQC 5 t P700 IMPORTANT Do not release the pressure without supervision X When relieving the pressure hydraulic liquid flows from the measurement W fv device into the reservoir Pressure equalisation in the reservoir occurs through the safety valve in the seal In the event of large volume measurement devices or if hydraulic liquid has been refilled during pressure generation liquid can leak through the safety valve v Carefully drain the pressure and note the fill level in the reservoir TRAQC 5 P700 07 2014 E page 18 cn MAE Tradinco s Instruments The Calibration Company 8 Problems User Manual TRAQC 5 P700 CAUTION Material damage The hand pump cannot be repaired by the operator In the case of a defect the appliance must be sent back to the manufacturer for repair i Never open up the hand pump and or carry out any repairs yourself The following table details what problems you can solve yourself and how to solve them Pressure cannot be built up No further increase of pressure is possible Pressure fades unstab
16. oir may overflow Never connect the TRAQC 5 P700 directly to the hydraulic system with large volumes construction machines etc or an aggressive medium such as brake liquid Before ordering and installation check that the hand pump is suitable for your applications 3 5 Exclusion of liability We accept no liability for any damage or malfunctions resulting from incorrect installation in appropriate use of the device or failure to follow the instructions in this operating manual TRAQC 5 P700 07 2014 E page 7 v Tradinco X User Manual TRAQC 5 d P700 The Calibration Company 4 Safety instructions Before you install the TRAQC 5 P700 read through this operating manual oy If the instructions contained within it are not followed in particular the safety guidelines this could result in danger for people the environment and the device and the system it is connected to The TRAQC 5 P700 corresponds with state of the art technology This concerns the accuracy the operating mode and the safe operation of the device In order to guarantee that the device operates safely the operator must act competently and be conscious of safety issues TRADINCO provides support for the use of its products either personally or via relevant literature The customer verifies that our product is fit for purpose based on our technical information The customer performs customer and application specific tests to ensure that the
17. ou reduce the pressure fluctuations 8 5 2 to a minimum CAUTION Material damage Dd Te test sample the adapter and the seal must be free from impurities If impurities enter the hand pump through the pressure hose this may be damaged z Maximum torque of the pressure connections Reference 15 Nm g Test item 15 Nm Carry out the following steps for the commissioning and ventilation of the hand pump For this note also the warnings in section 8 7 1 Generating pressure v 1 Fill the storage container to approximately two thirds capacity with the required hydraulic liquid 2 Open the pressure relief valve by turning counter clockwise 3 Turn the reference manometer with matching seal in the hand pump s connection G 1 4 IMPORTANT Do not tighten the reference yet i 4 Carefully pump until the hydraulic liquid escapes at the connection and the piston system has been ventilated 5 Only then should you tighten the reference 6 Pump 5 10 times to ventilate the ventilation channels 7 Turn the pressure relief valve counter clockwise until it is firmly closed The steps 1 up to 5 are only required for the first commissioning or during removal of the reference 7 tranc S TRAQC 5 P700 07 2014 E page 12 v Tradinco w User Manual TRAQC 5 Pe eos P700 8 Connect the pressure hose to the hand pump s MINIMESS connection and tighten the connection 9 Tightly
18. perating the instrument By doing so possible damage to the instrument or damage caused by the incorrect use of the instrument can be avoided TRADINCO INSTRUMENTS warrantees the instrument in accordance with the Standard Terms and Conditions of the Instrument Trade as issued by the Association bearing the name Federation Het Instrument The Instrument Federation filed with the Clerk of Utrecht District Court on 13 January 1993 under number 16 93 and with the Chamber of Commerce and Industry in Amersfoort on 18 January 1993 A copy is available on request TRADINCO INSTRUMENTS warrantees that this product will be free from defects in materials and workmanship for a period of 5 years from the date of shipment If any such product proves defective during this warranty period TRADINCO INSTRUMENTS at its option will either repair the defective product without charge for parts or labour or will provide a replacement in exchange for the defective product In order to obtain service under this warranty Customer must notify TRADINCO INSTRUMENTS of the defect before the expiration of the warranty period and make suitable arrangements for the performance of the service Customer shall be responsible for packaging and shipping of the defective product to the service centre designated by TRADINCO INSTRUMENTS with shipping charges prepaid If no defect can be found Customer may be charged for costs of the investigation This warranty does not apply to
19. product is suitable for the intended use With this verification all hazards and risks are transferred to our customers our warranty is not valid 4 1 Qualified personnel A The personnel who are charged for the installation and operation of the TRAQC 5 P700 must hold a relevant qualification This can be based on training or relevant tuition The personnel must be aware of this operating manual and have access to it at all times 4 2 General safety instructions A In all work the existing national regulations for accident prevention and safety in the workplace must be complied with Any internal regulations of the operator must also be complied with even if these are not mentioned in this manual A Never use the hand pump together with an external pressure source Do not attach an external pressure generator to the hand pump A Do not use brake liquid or other aggressive media A Hydraulic oils may cause irritation in case of skin contact Take suitable protective measures to avoid skin contact Observe the manufacturer s operating manual or the safety data sheet A Do not remove any attached components test item pressure hose reference gauge when the hand pump is under pressure A S Open the pressure relief valve before removing any of the components A Do not use Teflon tape to seal the pressure connections Surplus Teflon tape can enter the hand pump and damage it A Only use adapters and seals that are available
20. se observe the following notes concerning the operation of the hand pump e Ensure that no air is suctioned during the pumping process gt To ensure that this does not occur hold the hand pump at a slight angle so that the suction nozzles are always surrounded by hydraulic liquid e Ensure that there is sufficient hydraulic liquid in the reservoir If necessary refill the hydraulic liquid This must also be ensured during depressurisation 7 6 e For small hydraulic volumes and well ventilated systems a higher pressure is already built up with a few movements of the pump gt Ensure that the maximum permitted pressure is not exceeded e From approximately 400 500 bar a lot of strength is required for pumping from the initial position of the handles Increase the pressure using the fine adjustment valve and note the following tip TIP At high pressures open the handle only lightly z The handles can be compressed more easily the further the handles are closed In this way you can create high pressures more easily and meter i the pressure better The higher the pressure is the less you should open the handles In the event of high pressures avoid the initial position of the handles TRAQC 5 P700 07 2014 E page 15 Tradinco y User Manual TRAQC 5 TGS RT P700 The Calibration Company 7 3 Hand pump operation Switch on reference gauge and test item if necessar
21. ssure hose causes a reduction in the volume and thus leads to an increase in pressure At high pressure the pressure hose extends Furthermore enclosed air can be diffused through the pressure hose In both cases a drop in pressure results Temperature influence Temperature changes lead to a change in volume in the measurement device and therefore to changes in pressure The smaller the volume is the greater the change in pressure Settling times of reference and test sample Observe the required waiting times after the reference and test sample have been switched on More information on this can be found in the corresponding operating manual TRAQC 5 P700 07 2014 E page 11 v Tradinco wy User Manual TRAQC 5 P eenas P700 6 Commissioning with ventilation CAUTION Risk of injury in case of damage Visual inspection required before use Damage to the device or its attachments can result in component failure and injuries when the equipment is under pressure Check the TRAQC 5 P700 carefully for damage Never use the TRAQC 5 P700 if you have found any damage Return the device immediately to the manufacturer for repair In order for the hand pump to be operated it is vital that its connections with the reference gauge and the test item are pressure resistant Furthermore for the best measurement procedure possible sufficient and correct ventilation of the measurement device is required Only then can y
22. ustment or calibration of pressure measuring devices pressure gauges of all kinds The hand pump can be used for test items directly on location thanks to its light weight and compact design The hand pump and the pressure hose have MINIMESS connections When the hand pump is used it needs to be Pressure connected to a reference gauge and to the test hose item 3 1 Type plate and label You find the type plate on the lower pump body It includes the essential technical data and instructions An additional indication of the maximum allowable hand pump pressure is located on the upper pump body 3 2 Scope of delivery and accessories Check the delivered items and ordered accessories e Hand pump e Pressure hose e Operation manual e Ordered accessories TRAQC 5 P700 07 2014 E page 5 v Tradinco y User Manual TRAQC 5 siesta eee P700 3 3 Accessories optional Transportation cases MINIMESS adapter adapter sets seal sets and reference gauges can be ordered as accessories e Transportation case The transportation case provides optimal Adapter protection for the hand pump and other Ouse e m accessories with its tight fitting rigid foam inlay M12x1 5 B z A document compartment is located in the y E lid behind the burl foam inlay MINES m 3 e MINIMESS Adapter AE ge Npr 1 8 e Filling bottle Se Seal set e Adapter set The adapter set comprises 12 adapters
23. y Close pressure relief valve e Turn the knob of the valve ina clockwise direction until the stop is reached Create pressure e Push the hand grips together The pressure is built up e Repeat the pumping movements until the necessary testing pressure has roughly been reached Adjust the testing pressure The necessary testing pressure is precisely adjusted with the fine adjustment valve e Turn the hand wheel in a clockwise direction to increase the pressure e Turn the hand wheel of the valve in an anti clockwise direction to reduce the pressure e Set the necessary testing pressure by turning the wheel as needed Releasing pressure Turn the pressure relief valve knob 1 2 rotations in an anti clockwise direction and wait until there is no longer any positive pressure 7 4 Increasing pressure with the fine adjustment valve Alternatively you can increase the pressure Pump body with the fine adjustment valve stop collar Turn the hand wheel in a clockwise direction in the direction of the pump body stop collar Depending on the pressure of the test item and the setting of the hand wheel pressure Storage _ can be achieved quite easily transportation Pressure relief valve stop collar NU FINE ADJUSTMENT VALVE 2 z When it is not under pressure the fine adjustment valve moves very freely W The wide hand wheel of the fine adjustment valve can be moved into the needed position very
Download Pdf Manuals
Related Search
Related Contents
Power Mower 5400 5400 KL Operating Instructions Waterpik Technologies JP-120 User's Manual mikroPASCAL - PIC Vietnam WATER MIST (6 LITRE) EXTINGUISHER USER GUIDE Alphanumeric Pager User Manual Logique combinatoire - UVT e-doc M0056_BAVONO PTM-520DN 英文說明書 (eng).ai Emerson T205B Instruction Manual DocBook to LaTeX Publishing Dear consumer, Copyright © All rights reserved.