1. Front Door Qty EM 1001 1002 LED Light Bar Smoke Sensor Door Sensor Flashing LED Beacon Temp amp Humid Sensor Shock Sensor Fan Unit PDU Water Sensor Location rackmount on rear top front amp rear top inside rear inside top top corner of door front cabinet roof any inside position upper inside door mount or rackmount vertical or rackmount surrounding cabinet on floor P3 www RackmountMart com lt 1 3 gt Installation Diagram One Box Two Cabinets e 0 Front Door Cabinet 1 EM 1001 1002 LED Light Bar omoke Sensor Door Sensor Flashing LED Beacon Temp amp Humid Sensor Shock Sensor Fan Unit PDU Water Sensor a Front Door Cabinet 2 either smoke sensor or shock sensor P4 www RackmountMart com lt 1 4 gt Environmental Management Box EM 1001 Master Box 8 7 8 9 f 1st level Mind en EN re la i mad P soa Power input Temp LED display x 2 Dual power input option Door sensor port x 4 smoke Shock sensor port x 2 LED Light Bar port x 2 Port for 3rd party alarm board x 1 LAN port RJ 45 connect to network device OUT port RJ 45 connect to level 2nd slave EC box Dip switch level setting LED beacon port x 1 Temp amp Humid sensor port x 2 PDU port x 1 RJ 45
2. Enable www RackmountMart com lt 6 2 gt Sensors In lt Sensor Status gt user can monitor sensors s status in details based on Master IP group Sensor Status Master IP group no Page 4 Box Temp Humid 6 5 Level Location Location 01 Rack 001 S1 Front Middle 001 Auto deta refresh OOOO Press F11 to enlarge or diminish the screen In Sensor Setting gt user can modify 53 Location Status S3 Top 001 SA Top 002 Smoke Shock Location Connected S5 Bottom 001 Connected 56 Location of T TH sensor smoke shock sensor water sensor amp LED light bar Alarm setting amp Rising alert setting of T TH sensor Click Apply to finish the above settings Level6 Rack_001 Name Location SA TITH1 Location Front Middle 001 Alarm setting R alert setting Temp C 35 0 30 0 Humid 55 60 3 Smoke 1 Shock 1 Location Top 001 Status Connected 55 Water 1 Location Bottom 001 Status Connected 57 Lamp 1 Location Rear Door 001 Status OFF Apply Save new dats Cancel Cancel new data input Retum to SENSOR STATUS Reading 25 4 53 S2 T TH2 Location Alarm setting R alert setting Reading Temp C Humid 3 54 Smoke 2 Shock 2 Location Status Top_002 Connected 56 Water 2 Location Status s Lamp 2 Location Front Door 002 Status OFF P 46
3. Alarm interval Step 7 Input the alarm recipient email account in Email address 01 Step 8 Repeat step 7 from other alarm recipients if necessary Step 9 Click Apply to finish the alarm email server settings Alarm email server setting Alarm email i 7 Disable This alarm setting ts for all Master IP groups SMTP servet 192 168 0 1 MTP pari 25 POPS server 132 169 0 1 POPIp 110 examplegitemail com User name Password Alarm interval 10 Min 10 Max 60 minutes Alarm email to Alarm mail recipient 01 Alarm mail recipient 02 Alarm mail recipient 03 Alarm mail recipient 04 Alarm mail recipient 05 Save new data Cancel new data input P 40 www RackmountMart com lt 5 1 gt System Setup In lt General gt administrator can change the Refresh rate Scan rate amp Temperature unit across all Master IP groups Auto data refresh Refresh rate 20 Min 10 Max 8D seconds Ain data refresh rate on the page of EC BOX OVERVIEW SENSOR STATUS POU STATUS POU DETAILS FAN UNIT STATUS FAN UNIT DETAILS and DOOR STATUS Master IP groups auto scan Scan rale a Min 5 Max 60 seconds Anio scan rate on the page of EC BOX OVERVIEW SENSOR STATUS POU STATUS FAN UNIT STATUS ard DOOR STATUS Temperature unit Unii W c Save new daia Cancel new date input In lt Backup gt administrator can Enable or Disable the daily data backup
4. Setup purpose refer to P 39 Gateway 192 168 0 254 i JA Step 4 Click Scan to search the Master box Step 5 Enter device name in Name min 4 char max 16 char Default is Name Step 6 Enter device location in Location min 4 char max 16 char Default is Rack 001 Step 7 Enter password in Password for authentication min 8 char max 16 char Default is 00000000 Step 8 Enter new password in New password min 8 char max 16 char Step 9 Re enter new password in Confirm new password Step 10 Change the desired IP address Subnet mask Gateway then Click Save to confirm the changes The default IP setting is as below Write down the new IP address amp password IP address 192 168 0 1 Subnet mask 255 255 255 0 Gateway 192 168 0 254 P31 www RackmountMart com lt 4 3 gt Hardware Requirements of The Management PC Please prepare a management PC with the hardware requirements as below for Software Management IGM 03 Recommended hardware requirements Processor Dual Core 2GHz or above Memory 2GB RAM Available Disk Space 500GB Display 1440 x 900 or higher resolution monitor A The default service port of web server is 80 A dedicated PC to run Software Managemant IGM O3 is recommended Make sure the management PC is POWER ON 8 IGM O3 is unde
5. 81 Connected Connected Connected Connected Connected Connected 2 Disabled Disabled Disabled Disabled Disabled Disabled 53 Connected Connected Connected Connected Connected Connected S4 Connected Connected Connected Connected Connected Connected S5 Connected Connected Connected Connected Connected Connected S6 Disabled Disabled Disabled Disabled Disabled Disabled S7 Connected Connected Connected Connected Connected Connected S8 Connected Connected Connected Connected Connected Connected First Previous 1 2 3 4 5 6 7 10 Next Last Last 2000 log records Press F11 to enlarge or diminish the screen PDU log provides past 2000 log records of PDUs connect in each EC box The software will generate a PDU log in every 10 mins PDU log Box level PDU level Circuit A Circuit B Am Amp Max Load Alarm R alert L alert Max Load Alarm R alert L alert Date Time Model Location 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 07 21 37 07 11 36 V24C13 32A WSI V24C13 32A WSI V24C13 32A WSI V24C13 32A WSI V24C13 32A WSI V24C13 32A WSi Rear Left 001 160 00 130 00 00 i 16 0 0 0 130 0 0 0 0 Rear_Left_001 16 0 0 0 130 0 0 0 0 16 0 0 0 13 0 0 0 0 0 Rear_Left_001 16 0 0 0 13 0 00 0 0 i 16 0 0 0 13 0 0 0 0 0 Rear Left 001 16 0 0 0 130 0 0 0 0 ki 16 0 0 0 13 0 0 0 0 0 Rear Left 001 16 0 0 0 130 0 0 0 0 16
6. close door inductive sensor detects the cabinet frame DOOR CLOSE SIGNAL sends out Cabinet frame Door frame CLOSED Lo DI Lo c Sensing distance amm DOOR OPEN open door inductive sensor lose detection with cabinet frame Red LED of sensor light up DOOR OPEN SIGNAL sends out Cabinet frame OPENED Sensing distance gt 3mm P12 www RackmountMart com lt 2 2 gt Door Sensor Mechanical Door Sensor EMS 501 2 Features e low cost precise e cost efficient integration to new cabinet Package content e Mechanical sensor w 2m cable x 2 e Mounting screws 6 32x4 5mm x 2 Front View 52 0 Steel mounting plate with 2 screw holes Cable connector Press button Requirements A custom hole cutting required on doors ordering a sample for custom cutting is highly suggested min actuation distance 3 00 mm total travel distance 9 25 mm Top View total travel distance 9 25 mm min actuation distance 3 00 mm Polo unit mm Side View unit mm 375 5 2 9 9 Dimension of door cutting hole circle hole x 2 for screw mounting rectangle hole x 1 for sensor installation www RackmountMart com lt 2 2 gt Door Sensor Suggested Installation steps sensor position to EM box connect to the EM box E po place the sensor at the top middle of the door i install the sensor in the custom ho
7. Location S7 Rear Door 001 S8 Front Door 002 www RackmountMart com lt 6 3 gt PDU In PDU Status gt user can monitor PDU s status in details based on Master IP group PDU Status PDU Model Location Pt V24C13 324 WSi Rear_Left_001 P2 V24C13 30A WSi Rear Right 001 Auto dats refresh OLIOLI Press F11 to enlarge or diminish the screen Circuit A Circuit B Max Load Alarm R alert L alert Max Load Alarm R alert L alert 160 00 130 00 00 150 00 130 100 00 160 00 130 00 00 150 DO 130 100 00 Am Am In PDU Setting gt users can PDU Setting 02 Connected Rack 002 Rack 002 01 w V24C13 30A WSi Connected Rack 001 Rear Right 2013 07 18 14 22 39 2013 07 18 14 23 26 Amp Load Alarm R alert L alert Load Alarm R alert L alert outlet name Di DO 50 outlet name 02 00 100 outlet name __03 10 outlet name 04 outlet name 05 outlet name 06 outlet name 07 outlet name 08 outlet name 09 outlet name 10 outlet name 11 9 outlet name 12 Click outlet icon for setting E Auto data refresh TITI Untick during data i Save new data Cancel new data input Exit Retum to POU STATUS Press F11 to enlarge or diminish the screen zay 00 0 0 0 0 0 0 0 0 00 00 00 nput Change Name and Location of PDU Change A
8. up to PDU daisy chain level x 4 Fan unit port x 1 RJ 45 up to fan unit daisy chain level x 4 6660000 D water sensor port x 2 EM 1002 Slave Box From 2nd 16th level 0 00000080 lt A Only for Slave Box W Link 8 Out port RJ 45 for daisy chain connection P5 www RackmountMart com lt 1 5 gt Level Setting Steps B Only EM 1001 built in IP remote access module B EM 1001 MUST be set on the 1st daisy chain level according to the table below B Forthe 2nd 16th levels slave box please make the level setting according to the table below B For the cabling connection please refer to the next page ON MINIT l 123456 7 8 Daisy chain level setting Using the dip switch no 1 2 3 amp 4 to setup each box level as below Cascaded EC boxes Dip switch no 4 5 1st level Master bok 10th level Slave EC bok 11th level Slave EC box 12th level Slave EC box 13th level Slave EC box 14th level Slave EC box 15th level Slave EC box 16th level Slave EC box e gt 2 ge Q Q Q e D Q gt RI 5 RR RI IZF 3S 15S hR hR R hR R R RR 1353 13 15 13 35 135 S he a IS S SIS SSS ee Q No 5 6 7 amp 8 dip switch reserved P 6 www RackmountMart com lt 1 6 gt Daisy Chain Remarks B Each Master IP group supports 16 daisy chain
9. 0 0 0 13 0 0 0 0 0 Rear_Left_001 16 0 0 0 130 00 0 0 16 0 0 0 13 0 0 0 0 0 07 01 35 06 51 34 06 41 33 06 31 32 First Previous 1 2 3 4 5 6 7 8 9 10 Next Last Last 2000 log records Press F11 to enlarge or diminish the screen PDU Outlet log provides past 2000 log records of each PDU s outlet The software will generate an outlet log record in every 10 mins PDU Outlet log Box level POU level 01 01 01 Outlet level Am Date Time Model Location Name Status Load Alarm A alert L alert 2013 06 20 2013 06 20 07 21 39 07 11 38 V24C13 32A WSi W24C13 324 WSi Rear Left_001 Rear Left 001 outlet name 01 ON DO 100 50 00 outlet name 01 00 100 50 Ff 00 W24013 324 WSi V24C13 32A WSi 2013 06 20 2013 06 20 07 01 37 06 51 36 06 41 35 06 31 34 Rear Left 001 Rear Left 01 Rear Left O01 Rear Left Q0 outlet name 01 0 0 10 0 5 0 0 0 outlet name 01 0 0 10 0 50 i 00 outlet name 01 0 0 10 0 5 0 0 0 outlet name 01 DO 10 0 5 0 0 0 2013 06 20 2013 06 20 V24013 32A WSi V24C13 32A WS5i Last 2000 log records Press F11 to enlarge or diminish the screen www RackmountMart com P 58 Part VII Events Log Report lt PDU TH Sensor log gt provides past 2000 TH log records of each PDU The software will generate an outlet log record in every 10 mins PDU TH sensor log Box level 01 v PDU level 01 v TH 1 TH 2 C
10. 168 0 1 IGM 03 Step 3 Enter User name Default is admin Enter Password Default is 00000000 System authentication User name Password 5555555 Login user Login user Login user Login user Login user AA Router or hub Management PC N P InfraGuard Manager IGM 03 Then users should go to lt User gt lt Setup gt lt Alarm gt lt General gt 8 lt Backup gt for initial system setup A Only Administrator is authorised to access lt User gt lt Setup gt lt Alarm gt lt General gt amp lt Backup gt P 37 www RackmountMart com lt 5 1 gt System Setup In lt User gt page administrator can create 4 more operators Step 1 Tick Operator 1 Step 2 Inout User name amp User login password Step 3 Input user login password in Confirm password again Step 4 Repeat Step 1 to 3 for other operators if necessary Step 5 Click Apply to finish the user setup User setup Activate Username User login password Confirm password m Administrator admin Sesssototeontaete DLL Only administrator is authorised to access SYSTEM SETTING Only administrator is authorised to set and change all users password Min 4 char and max 16 char for user name Min 8 char and max 16 char for user login password fthere is any change of user name system will automatically delete the original oper
11. Consumption 0 375A 45 wan Housing Extruded aluminum with silver powder coat Acrylic with milky white Installation Magnetic base for unrestricted installation Connection Cable Length 2m 3m option Environmental Operating 20 to 50 C Degree Relative Humidity 5 90 non condensing Dimensions Product 300L x 20W x 12H mm Weight Net 84g Compatibility X 2000 series EM 1001 1002 FCC amp CE certified Safety Regulatory Environmental RoHS2 8 REACH compliant P 19 www RackmountMart com lt 2 8 gt LED Beacon The LED Beacon can be stuck firmly by the bundled adhesive tape FE CE REACH RoHS n en LED Beacon Notification Flash Rate 120 flashes per minute Power Requirement Voltage 12VDC powered by sensor port Current Consumption 0 175A Housing Polycarbonate Connection Cable Length Im 3m Environmental Operating 20 to 50 C Degree Storage 20 to 60 C Degree Relative Humidity 5 90 non condensing Dimensions KN QOO 1 Product 72L x 72W x 45H mm Weight 50g LED Beacon with 1m cable Supply includes Compatibility X 2000 series EM 1001 1002 Safety Regulatory FCC amp CE certified Environmental RoHS2 8 REACH compliant P 20 www RackmountMart com Part lil PDU Fan Unit Installation amp Specifications lt 3 1 gt PDU Under EM 1001 network each Box supports intelligent PDU x 4 in a daisy chain Each PDU com
12. Features 4 2 Master IP Configuration lt 4 3 gt Hardware Requirements of The Management PC lt 4 4 gt Supported OS Platform amp Language lt 4 5 gt Software Download lt 4 6 gt First Time Start up Setting lt 4 7 gt Change Port No of Web Server Part V System Setup amp Remote Access 0000000 P 37 lt 5 1 gt System Setup lt 5 2 gt Remote Access Part VI Device Monitoring amp Setting 2 P 44 6 1 Device Overview 6 2 Sensors 6 3 PDU 6 4 Fan Unit lt 6 5 gt Door Part VII Events Log Report P 57 Part VIII SNMP ee III III HII hh rrr P 64 Panik FAO Js ERREUR aa a RERO RECAP EH RHENUM wl Rad AO ARR Rr E a P 66 Part X Troubleshooting eeerbeod bsquasuAM equa get ga tee vayan oye Dan P 68 Part XI Optional Accessories eee P 72 www RackmountMart com Part I Hardware lt 1 1 gt Package Contents Unpacking The equipment comes with the standard parts shown on the package contents Check and make sure they are included and in good condition If anything is missing or damage contact the supplier immediately EM 1001 Master Box x 1 OR EM 1002 Slave Box x 1 6 Power cord x 1 6 Power cord x 1 FE CE REACH 1 2 Features amp Specifications EM 1001 EM 1002 Master Bok Slave Bok Daisy Chain 1st Level 2nd 16th Level SNMP via Master Box LAN Port Daisy Chain Port L
13. Installation BM itis very important to locate the equipment in a suitable environment M The surface for placing and fixing the equipment should be stable and level or mounted into a suitable cabinet B Make sure the place has good ventilation is out of direct sunlight away from sources of excessive dust dirt heat water moisture and vibration HM Position the equipment with respect to related facilities EM 1001 1002 Installation WH Suggest the installation at the rear top mounting of cabinet M M6 screws set not provided NENGA aa X VA VS A dd cc NI NG w NIN QN NN NN dd mandat www RackmountMart com Content Parti Hafdwart ccrrperesasiceianinnia te aerei vai P 1 1 1 Package Contents lt 1 2 gt InfraGuard Features amp Specifications lt 1 3 gt Daisy Chain Group lt 1 4 gt EM 1001 1002 lt 1 5 gt EM 1001 1002 Level Setting 1 6 EM 1001 1002 Daisy Chain Part Il Sensor Installation amp Specifications P 8 2 1 Overview 2 2 Door Sensor 2 3 Temp amp Humidity Sensor 2 4 Smoke Sensor 2 5 Shock Sensor 2 6 Water Sensor 2 7 LED Light Bar 2 8 LED Beacon Part Ill PDU Fan Unit Installation amp Specifications P 21 3 1 PDU 3 2 Fan Unit www RackmountMart com Content Part IV Software eee cece eee rire re rire rec ire cere s esses e e P30 lt 4 1 gt Key
14. Name Location Step 8 Enable alarm email in lt Alarm gt page 2 How to replace a failed certain level slave Box with a new one Step 1 Prepare a new slave Box and set the slave Box level accordingly Please refer to user manual lt 1 5 gt for details Step 2 Prepare an appropriate length Cat 5 6 cable Step 3 Disable alarm email in lt Alarm gt page Step 4 Use a Cat 5 6 cable to bridge over the failed slave Box which will be replaced to minimize log data loss Step 5 Power off and remove the failed slave Box from connection Step 6 Install the new slave Box cancel the cable bridging and reconnect the slave Box to the previous and next one Step 7 Power on the new slave Box Step 8 Configure the new slave Box in lt EC Box Setting gt page such as Name Location Step 9 Enable alarm email in lt Alarm gt page di Ignore step 2 and 4 if the failed slave Box is in the last level P 69 www RackmountMart com Part X Troubleshooting 3 How to move out a slave Box without a replacement Step 1 Prepare an appropriate length Cat 5 6 cable Step 2 Disable alarm email in lt Alarm gt page Step 3 Use the Cat 5 6 cable to bridge over the removed slave Box to minimize log data loss Step 4 Power off and remove the slave Box from connection Step 5 Reconfigure and reset the level for the affected slave Box es which next to the removed slave Box Step 6 Disable the removed
15. normal high max Switch ON OFF individual fan Fan Unit Setting Box level Status Connected Name Levell Location Rack 001 Fan unit H w RF 1 3 1U Fan Tray Stalus Connected Unit switch i Temp Sensor Name FanHame01 Temp 26 5 Location FanLocation 1 Unit CFM N Auto data refresh EELILLLLILI Untick during data input Apply Save new data Cancel Cancel new data input Ext Return to FAN STATUS Press F11 to enlarge or diminish the screen P 54 www RackmountMart com lt 6 4 gt Fan Unit In lt Temp Setting gt user can Activate or Deactivate temp sensor Change Location of temp sensor Enable or Disable auto CFM control Change Alarm temp amp Rising alert temp of temp sensor Click Apply to finish the above settings Temp Setting Connected Rack O02 Location Rack 002 Fan unit RF 1 3 1U Fan Tray Status Connected Rack O02 Location Rack DO2 22U Temp sensor F Deactivate Wi Activate DO NOT activate temp sensor if no sensor installed Otherwise temp sensor disconnection event will be logged When install temp sensor please tick activate Otherwise no readinas display Locaton Front TopO01 When temp alarms triggers 1 All individual fans will change to Max speed if auto CFM control is enabled 2 If the temp drops under the alarm temp MINUS 2 C within 10 mins the buzzer will not soun
16. outlet schedule can be set on one time daily or weekly basis To set the outlet schedule please follow the steps in next page Outlet Schedule Setting Box level Status Connected Mame Rack_002 Location Rack_002 Outlet schedule Mame Action Time Outlet schedule V24013 30A WSi in uL as am L A z oF b m A a Jo i i Disable 7 Enable OutletSchedule01 A OFF mon Daily Weekly One Time 01 DI w MM DD date format SUN w 00 OO 24hours format outlet_name_ 01 outlet name 02 outlet name 03 outlet name 04 outlet name 05 outlet name 06 outlet name 07 outlet name Q8 outlet name 09 outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 a F m Am outlet name 18 outlet name 19 outlet name 20 outlet name 21 outlet name 22 outlet name 23 outlet name 24 Save new data Cancel new data input Return to OUTLET SCHEDULE V24C13 30A WSi outlet name 01 outlet name 02 outlet name 03 outlet name 04 outlet name 05 outlet name 06 outlet name 7 outlet name 08 outlet name 08 outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name 19 outlet name 20 outlet name 21 outlet name 22 outlet name 23 outlet name 24 Eg Fm Eg pg Fx Fu pu p pm pm pm pr p
17. slave Box in lt Setup gt page Step 7 Enable the Box es in lt Setup gt page based on the new level setting in Step 5 Step 8 Click Apply to save the setting change Step 9 Enable alarm email in lt Alarm gt page A Ignore step 1 3 5 and 7 if the removed slave Box is in the last level 4 How to add an extra slave Box to an existing Master IP group Step 1 Prepare a new slave Box and set the slave Box level accordingly Please refer to user manual 1 5 for details Step 2 Prepare an appropriate length Cat 5 6 cable Step 3 Disable alarm email in Alarm gt page Step 4 Install connect and power on the new slave Box Step 5 Reconfigure and reset the level for the affected slave Box es which next to the added slave Box Step 6 Enable the added slave Box in lt Setup gt page Step 7 Enable the Box es in lt Setup gt page based on the new level setting in Step 5 Step 8 Click Apply to save the setting change Step 9 Configure the new slave Box in lt EC Box Setting gt page such as Name Location Step 10 Enable alarm email in lt Alarm gt page A Ignore step 3 5 7 and 11 if the added slave Box is in the last level P 70 www RackmountMart com Part X Troubleshooting 1 Try to login IGM 03 but the web browser only shows HTTP 404 Not Found Step 1 Services for web server in management PC started Make sure the services is started Go to Control P
18. start up setting is completed Step 1 Go to the path of web server being installed Default C AppServ Apache2 2 conf Step 2 Open httpd conf amp change Listen 80 to Listen xx where xx means the port users want to use save the change bg Ej httpd conf I powemel 145 mib Listen Allows vou to bind Apache to specific IP addresses and or ports instead of the default See also the VirtualHost directive Change this to Listen on specific IP addresses as shown below to prevent Apache from glomming onto all bound IP addresses 0 0 0 0 t 18 80 This configuration file reflects default settings for Apache ETIP Server E f You may change these but chances are that you may not need to H i Timeout The number of seconds before receives and sends time out Timeout 300 Step 3 Restart Apache services Go to Control Panel gt Administrative Tools gt Services gt Apache2 2 amp Click Restart Complete P 36 www RackmountMart com Part V System Setup amp Remote Access lt 5 1 gt System Setup Users can follow below step 1 3 to access the management PC and InfraGuard Manager IGM 03 Step 1 Open Internet Explorer I E version 8 0 9 0 or 10 0 Step 2 Enter the URL of management PC into the address bar 4 If fail to access please ask MIS to check if the port for web server is enable Default port 80 e g http 192
19. user name and password of IGM 03 Default user name admin and password 00000000 8 What is the command password of IGM 03 Each Master IP group has its command password It will be requested for any device configuration and control connected to the EC Box The administrator can set different password for each Master IP group or all Master IP groups use the same command password P 66 www RackmountMart com Part IX FAQ 1 How accurate is the Temp amp Humid sensor It is accurate to 0 5 C typical and 4 5 RH typical 2 How accurate is the Temp sensor It is accurate to 1 0 C typical 3 What is sensitivity of smoke sensor 0 15 0 3 dB m 4 What is the detection radius of shock sensor 3 5m 5 What is the lumen of the LED light bar 250 lumen Master EC Box 1 What is the Master Box The Master Box has a built in IP remote module which provides a simple and economical way to consolidate management of max 16 Slave boxes by a single IP connection to the network 2 What is the IP Setup Utilities This is a Windows based application used to assign the IP address of Master Box You can download the IP Setup Utilities from the link below http www rackmountmart com downloads html 3 Does the EC Box has dual power input Yes MUST order before delivery 1 Where can I find the Catalogue User manual Model list of EM 1001 1002 Please visit www Rackm
20. 26 Yo Date Time Model Location Location Temp Alarm R alert Humid Alarm R alert Location Temp Alarm R alert Humid Alarm R alert 2013 06 20 07 21 37 V24C13 32A WSI Rear Left 001 THLocation 01 28 3 350 300 515 650 600 THLocation 02 269 350 30 0 494 650 600 2013 06 20 07 11 36 V24C13 32A WSi Rear Left 001 THLocation 01 28 3 350 30 0 515 650 600 THLocation 02 269 350 30 0 494 650 60 0 2013 06 20 07 01 35 V24C13 32A WSi Rear Left 001 THLocation 01 282 350 30 0 515 650 600 THLocation 02 269 350 30 0 49 4 650 60 0 2013 06 20 06 51 34 V24C13 32A WSi Rear Left 001 THLocation 01 28 3 350 30 0 515 65 0 600 THLocation 02 289 350 30 0 49 4 650 60 0 2013 06 20 06 41 33 V24C13 32A WSi Rear Left 001 THLocation 01 282 350 30 0 515 650 600 THLocation 02 289 350 30 0 49 4 650 60 0 2013 06 20 06 31 32 V24C13 32A WSi Rear Left 001 THLocation 01 282 350 300 515 650 600 THLocation 02 289 350 30 0 48 9 650 60 0 First Previous 1 2 3 4 5 6 7 8 9 10 Next Last Last 2000 log records Press F11 to enlarge or diminish the screen Daily kWh log PDU gt provides past 2000 daily energy consumption log records of each PDU The record is logged at 00 00 everyday 5 mins for previous day The PDU kWh log will not be recorded at 00 00 if the PDU connected is less than 24 hours Daily kWh log PDU Box level 01 ka POU level 01 C
21. 41 Click Apply to finish the above settings Click Reset to reset peak amp or kWh of outlet Outlet kWh Switched PDU only Outlet Setting Bax level 02 Sian Connected Name Rack 002 Rack 007 01 V24013 30A NSi Connected Name Rack OU Location Hear Riant oil a outlet name 07 Status ON Power Up Sequence delay 1 Min 1 Max 10 seconds 1 Load amp Aam arme Rising alert amp LOW alert amp Peak amp 2013 0701 f 164240 Kvn 20107517 16 42 55 Apply Save new data Cancel Cancel new data input Return to PDU SETTING P 48 www RackmountMart com lt 6 3 gt PDU In lt TH setting gt user can Activate or Deactivate Temp 8 Humid sensor Change Location Alarm setting 8 Rising alert setting of Temp amp Humid sensor Click Apply to finish the above settings TH Setting Box level 02 Status Connected Name Rack_002 Rack_002 01 V 12013 4019 32A WSi Status Connected Name default_pdu_nam PDU_default_loc Deactivate Activate Deactivate C Activate DO NOT activate T or TH sensor if no sensor installed c c ocato 3 Torti THSensor 1 loc o cato When install T or TH sensor please tick activate Otherwise no readings display Rising alert Rising alert Reading Setting Reading Temp C 34 0 132 0 23 5 Temp C Humid 96 70 0 650 53 9 Humid Save new data Cancel Cancel new data input
22. 43 5 mm RA4015 6 R 480 x 458 3 x 43 5 mm 18 9 x 18 x 1 71 inch RA4015 9 R 480 x 623 3 x 43 5 mm 18 9 x 24 5 x 1 71 inch RA4017 6 R 195 x 42 9 x 1466 mm 7 1 x 1 7 x 57 7 inch RA4017 9 R 195 x 42 9 x 1466 mm 7 7 Xx 1 7 x 57 7 inch Mode Nawi RA4017 9 R 5 kgs 11 Ibs Safety Regulatory FCC amp CE certified Environmental RoHS2 8 REACH compliant P 29 www RackmountMart com Part IV Software lt 4 1 gt Key Features Software Management IGM 03 is a FREE environmental control management software to monitor up to 30 Master IP Groups remotely max 16 box levels in each Master IP Group total 480 boxes Each box can connect a variety of sensors to provide an environmental monitoring solution to secure high levels of data center operational stability and flexibility To enhance the functionality up to 1920 x kWh PDU Fan Unit can be monitored through IGM 03 GUI as well 5 concurrent user license is bundled to achieve the demand of multi user multi tasking in nowadays time sharing data center operation Software Management IGM 03 Features e Capacity Master IP Group Just 1 IP for 16 EM box levels Numbers of boxes Concurrent user Device Status of Sensor PDU Fan Unit amp Door Sensor Status Monitoring Peripherals Location of Sensor Peripherals Temp Humid Alarm Rising Alert Threshold Setting DS CO PDU Energy Consumption kWh Amp Monitoring Outlet Level Measu
23. DC 100mA Alarm hold time Approx 2 0 sec Power Requirement Voltage 12VDC powered by sensor port Housing Chassis amp Cover ABS plastic White Connection Cable Length 1m 3m option Environmental Operating 5 to 55 C Degree Storage 10 to 60 C Degree Humidity 5 9096 non condensing Dimensions Product 26 x 85 x 24 mm Weight D prm JI O Shock Sensor with 1m cable Supply includes Compatibility X 2000 series EM 1001 1002 Safety Regulatory FCC amp CE certified Environmental RoHS2 amp REACH compliant P17 www RackmountMart com lt 2 6 gt Water Sensor FE CE REACH RoHS EMS 401 Measurement Range Wet or Dry 20 C to 60 C Rope Sensor Length 5 Power Requirement Voltage 5VDC powered by sensor port Extension cable length 3m non detection Part no Connection Environmental Operating 20 to 60 C Degree Storage 20 to 80 C Degree Weight Net 450g Sensor amp extension cable Supply includes Rope water sensor Extension cable Compatibility X 2000 series EM 1001 1002 Safety Regulatory FCC amp CE certified Environmental RoHS2 8 REACH compliant P18 www RackmountMart com lt 2 7 gt LED Light Bar LED light bar can be ON OFF by door sensor OR always ON by management software setting IIS A Fe Ce BEACH ___ _ LED Light Bar Power Requirement Voltage 12VDC powered by sensor port Current
24. Dissble alarm Change alarm email server setting Add Delete alarm mail recipient P 42 www RackmountMart com lt 5 2 gt Remote Access After administrator completes lt System Setup gt up to 4 additional users can access the management PC remotely User can follow the steps below to access management PC amp InfraGuard Manager IGM 03 Step 1 Add the port of web server in the firewall settings of the management PC Open Control Panel Select Windows Firewall Select Advanced settings Right Click Inbound Rules amp select New Rule Select Port 8 Click Next Select TCP then All local ports amp Click Next gt Select Allow the connection amp Click Next Tick all three options amp Click Next gt Input the Name amp Description of the port amp Click Finish Step 2 Open the web browser of remote client PC Step 3 Input the URL of InfraGuard Manager IGM 03 in the address bar e g http 192 168 0 1 IGM 03 If the port no of web server is not 80 please enter the appropriate port no follow the IP address e g http 192 168 0 1 81 IGM 03 Step 4 System authentication page pops up automatically Inout User name Password amp Click Login system authentication User name Password i Cancel P 43 www RackmountMart com Part VI Devices Monito
25. INK Daisy Chain Port OUT Dual Power Input Option Temperature LED Temp Humid Sensor Smoke Shock Sensor Water Sensor Door Sensor LED Light Bar LED Flashing Beacon iu nano MIF ERR N AN N NIL QQK x Alarm Board Integrated PDU 4 daisy chain 4 daisy chain Integrated Fan Unit 4 daisy chain 4 daisy chain Product Dimension WxDxH 400 x 135 x 39 7 mm 15 7 x 5 3 x 1 6 inch Net Weight 1 06 kgs 2 3 lbs Power Consumption Auto sensing 100 to 240VAC 50 60Hz Max 48 Watt Operating Temperature 0 o 55 C Degree Storage Temperature 5 to 60 C Degree Relative Humidity 5 90 non condensing Mounting 1U Rackmount Safety Regulatory FCC amp CE certified Environmental RoHS amp REACH compliant www RackmountMart com lt 1 3 gt Daisy Chain Group e EM 1001 as the 1st level master box e The EM 1002 can be cascaded up to 16 levels e Only 1 x IP for 16 x EM 1002 remote access e Daisy chain by Cat5 6 cable e Max distance between 2 boxes is 20M e Max distance in a daisy chain group up to 300M One network can expand up to 30 daisy chain groups master IP group Each daisy chain group supports up to 16 Boxes Each network can monitor 480 Boxes Each Box supports PDU x 4 amp fan unit x 4 Up to 1920 PDUs amp 1920 fan units can be installed under one Environmental Management network P2 www RackmountMart com lt 1 3 gt Installation Diagram One Box One Cabinet 2
26. IP switch for Unit CFM Setting daisy chain level setting Remole Fan Individual fan status Buttons for Alarm Individual fan On Temp Setting Off buttons Temp LED display o 0 4 amp TEMP LINK Q OUT 5 Temp port bundled w a temp sensor 6 Daisy chain LINK port for connecting to the out port of the last level fan unit 7 Daisy chain QUIT port for connecting to the link port of the next level fan unit EA de NG SNG ER A Ee P24 www RackmountMart com lt 3 2 gt Fan Uni C 5 D 0 2 o 0 uc cS 22 co lt 0 gt n 2 as I 0 0 0 0 0 e 0 0 0 0 0 0 0 0 0 0 0 00 out port of the last level fan unit D E cae du O D Cc S O D C xm cC C 9 3 L C oe ES o du B D c Q o C C amp o Os Aa m 2X sE I M S a a a LI age 6 Daisy chain LINK port for connecting to the Temp port bundled w a temp sensor gt C Gg Li E a J m e Sol Se i ie o aQ 0 OW gt gt 1 O OUO LL LL Lie E E gt D FE CE REACH ep Cc 9 5 o 4 O SO SOI Sc oO cc Tv dq oo V 3 fe C JO O gt gt co aff I de LO od TY o 3 er gt E q oO E A x amp IDAS IDAN G BALE WE HS QD so OO o L iz S o D r www RackmountMart com P 25 lt 3 2 gt Fan Unit Model RA4015 9 R 1U Fan Tray with 9 fans Unit CFM Status LED O DIP swit
27. ONLY Fan Unit Door Sensor E Disable Enable F1 4 Disable Enable D1 4 Disable E Enable Disable 7 Enable F2 V Disable IC Enable D2 V Disable Enable V Disable E Enable F3 V Disable Enable D3 V Disable 7 Enable IV Disable Enable F4 IV Disable Enable D4 W Disable Enable Appiy Save new data Cancel new data input Return to EC BOX OVERVIEW P 44 www RackmountMart com lt 6 1 gt Devices Overview In lt Audio and Visual Output Setting gt user can enable or disable Buzzer Beacon amp Alarm out output when sensor event is triggered Audio and Visual Output Setting eje Status Connected Box level Levela Rack 001 Name Location Sensor event 1 7 TH 1 temp humid alarm 2 7 TH 2 temp humid alarm 3 Smoke Shock 1 alarm 54 Smoke Shock 2 alarm 55 Water 1 alarm 56 Water 2 alarm Save new data Cancel new data input Return to EC BOX SETTING a Disable E Disable 7 Disable 7 Disable E Disable E Disable Buzzer E Enable E Enable E Enable Enable E Enable Enable P 45 Disable E Disable 7 Disable E Disable E Disable El Disable Beacon W Enable E Enable 2 Enable F Enable A Enable Alarm out E Disable 4 Disable E Disable 4 Disable 4 Disable E Disable E Enable Enable E Enable Enable E Enable
28. Reconnection Enable cisable T TH sensor Change smoke shock sensor location Enable disable smoke shock sensor Change LED lanp location Enable disable water sensor Enable cisable POU Enable disabile fer unit Enable Disable LED lanp w off LED lamp by door sensor 10 LED law alway on 11 LEO lanp always off 12 poor opened closed 15 Lanp on ofi EC box connection POu s TM sensor connection i Disconnection 2 1 Disconnection Reconnection 1 Change temp alarm 2 Reconnection i Change temp rising siert disable door sensor Change tunic alare eas Fw d tv hi de j Change T TM sensor location wes Fw d tr n w C bok sensor connection Fan unit connection Change honid rising alert T TH sensor disconmection 1 Disconnection 3 2 T TH sensor reconnection 2 Reconnection 3 3 Mater sensor disconnection Mater sensor reconmection Fan unit s tarp sensor connection 1 Disconnection 2 Reconnection mananan n e an PDU configuration tlet configuration POU s TH sensor configuration Change larm sap Suitch outlet on 7 off setivat cdesctivete TM Sensor Change rising alert asp Change owtlet name Change low alert anp Change power up secoence delay Reset peak amp Gate and tise Change alarm aap Reset Kh sw date and tise 4 Change teng alare 4 Chance POU n se 4 4 Li b gt Change teng ri
29. Return to PDU SETTING P 49 www RackmountMart com lt 6 3 gt PDU lt Outlet Schedule Overview gt provides a scan overview on all settings of PDU s outlet schedules based on Master IP group Outlet Schedule Overview Master IP group no 01 Page 1 2 Box Outlet Schedule 1 2 Outlet Schedule 3 4 Outlet Schedule 5 6 Level Location Setting Name Action Action Name Action 01 Rack 001 G OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled 02 Rack 002 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Rack 003 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Rack 004 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Rack 005 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Rack 006 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Rack 007 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Rack 008 OutletSchedule 1 Daily On Disabled Disabled OutletSchedule 2 Daily Off Disabled Disabled Auto data refresh TITIIIILII Press F11 to enlarge or diminish the screen P 50 www RackmountMart com lt 6 3 gt PDU In lt Outlet Schedule Setting gt user can set max 6 outlet On Off schedules in each Box The
30. When Enable the backup path can be changed Data backup setting Daily backup E Enable 7 Disable Backup to C Program Files x86 nfraGuard Manager IGM D3S Example C Program Fiesi G I Save new data Cancel new data input Daily backup proceeded at UUD for lasi 24 hours date The backup data for EC BOX LOG POU LOG POU OUTLET LOG POU SENSOR LOG POU KWH LOG POU OUTLET KWH LOG FAN UNIT LOG FAN LOG EVENT Y LOG saved in CSV fie format Folder Wah Backup will be automatically created Under the path you entered P 41 www RackmountMart com lt 5 1 gt System Setup lt Sys log gt provides past 2000 event records of lt User gt lt Setup gt lt Alarm gt lt General gt amp lt Backup gt First Previous 1 3 id 39 10 Next Last Last 2000 log records Date Time Description 2013 0618 16 01 02 Us admin Add operator Operator 01 kenny 2013 0648 17 59 32 admin Activate IP dongle group 02 2013 06 16 17 37 44 admin Activate IP dongle group 01 System setup events User 1 Add Delete administrator or operator General Change refresh made time rate Change user login password Change scan mode time rate Change temperature unit Activate Deactivate Master IP group Change Master IF address or pee Enable Disable Master IP group command password 1 Enable Disable daily backup Change Master IP group command password Change backup path Enabe
31. able disconnected loose or defective Check the Cat 5 6 cable connection to EC Boxes and network device Make sure the connectors are firmly attached And check if any defects on your cable or not If yes replace a new one Step 2 Master EC Box failed i Check if the network setting of the Master EC Box is correct or not If duplicate IP address is in the network it may cause such problem ii Disconnect the Master EC Box from the network and try to direct connect the Cat 5 6 cable from the lt LAN gt port to a computer network port and use IP Setup Utilities to check if Master EC Box can be found or not If it cannot be found the Master EC Box may be failed P 68 www RackmountMart com Part X Troubleshooting Replacement Removal Or Addition For EC Box 1 How to replace the failed Master Box with a new one Step 1 Prepare a new Master Box and set it to 1st level Please refer to user manual lt 1 5 gt for details Step 2 Configure the IP address of the new Master Box as the failed one Please refer to user manual lt 4 2 gt for details Step 3 Disable alarm email in lt Alarm gt page Step 4 Power off and remove the failed Master Box from connection Step 5 Install the new Master Box to the connection and power it on Step 6 Click Start Connection in lt Overview gt page for the relevant Master IP group Step 7 Configure the new Master Box in lt EC Box Setting gt page such as
32. al 480 boxes Each box can connect a variety of sensors to provide an environmental monitoring solution to secure high levels of data center operaional stability and flexibility To enhance the functionality up to 1920 x kWh PDU Fan Unit can be monitored through IGM 03 GUI as well 2 What OS platform does IGM 03 support MS Windows XP Professional with SP3 32 bit English edition only MS Windows 7 Professional with SP1 32 amp 64 bit English edition only MS Windows 7 Ultimate with SP1 32 amp 64 bit English edition only MS Windows 8 Professional with SP3 32 amp 64 bit English edition only MS Windows Server 2003 R2 Standard edition with SP2 32 amp 64 bit English edition only MS Windows Server 2008 Standard edition with SP2 32 amp 64 bit English edition only MS Windows Server 2008 R2 Standard edition with SP1 Ensure users login to the management PC as a member of Administrators group before IGM 03 installation and execution 3 Why user cannot login to the management PC remotely Make sure the port for web server is added in the firewall setting and the services of web server is started in the management PC 4 Which database does IGM 03 support PostgreSQL 5 What is the PostgreSQL default password for IGM 03 1qazaWSX 6 How can I receive alarm email and get full log report Make sure IGM 03 is executed and the alarm server is enabled and configured properly 7 Whatis the default
33. an Russia PRESE aa Long date 25 June 2015 16 Spanish Spain kaka k Tw 17 Turkish Turkey Long time Additional settings P 33 www RackmountMart com lt 4 5 gt Software Download Software download Please download the InfraGuard Manager IGM 03 to the management PC from the link http www rackmountmart com downloads html Double click the IGM 03 msi and follow the instruction to complete the installation IGM 03 msi Welcome to the InfraGuard Manager IGM 03 Setup Wizard The Setup Wizard will allow you to change the way InfraGuard Manager IGM 03 features are installed on your computer or even to remove InfraGuard Manager IGM 03 from your computer Click Mext to continue or Cancel to exit the Setup Wizard click Next click Install Completing the InfraGuard Manager IGM 03 Setup click Finish Wizard Click the Finish button to exit the Setup Wizard gt 00000000000 oO Complete P 34 www RackmountMart com lt 4 6 gt First Time Start up Setting 6 Step 1 Double Click InfraGuard Manager IGM 03 and follow the instruction to complete start up setting Infra IGM 03 InfraGuard Manager Step 2 Click Next in InfraGuard Manager start up setting box Step 3 Input the fields of the following window amp Click Install Software component s analysis amp installation The f
34. anMName01 FanMame01 FanMName01 FanName01 FanMName01 FanMame01 FanMame01 FanMame01 Press F11 to enlarge or diminish the screen Location FanLocation01 FanLocationO1 FanLocation0 1 FanLocationO1 FanLocationD FanLocation01 FanLocation0i FanLocation0i FanLocation0 1 10 Next Last P 60 No of fan Last 2000 bog records 26 6 26 6 27 0 26 6 26 6 26 6 26 6 26 6 26 9 www RackmountMart com 35 0 35 0 35 0 35 0 35 0 35 0 35 0 35 0 35 0 Temp Alarm R alert 0 0 0 0 0 0 0 0 0 0 30 0 30 0 30 0 30 0 Part VII Events Log Report lt Fan Unit fan log gt provides past 2000 log records about an individual fan of each Fan unit The software will generate a fan log record in every 10 mins Fan unit fan log Box level 01 Ed Fan Unit level 01 Fan level 01 Ed Time Name Location Status 11 30 39 FanHame 1 FanLocation 1 Normal 11 07 07 FanName01 FanLocation01 Normal 10 48 35 FanHamed1 FanLocationD1 Normal 10 38 34 FanHame 1 FanLocation 1 Normal 10 28 33 FanNamed1 FanLocationD1 Normal 10 15 01 FanNamedt FanLocation 1 Normal First Previous 1 9 10 Next Last Last 2000 log records Press F11 to enlarge or diminish the screen lt Door sensor log gt provides past 2000 log records about the door sensor The software will generate a door log record in every 10 mins Door sensor log Box level 02 Date Time Location Location Status Location Status Lo
35. anel gt Administrative Tools gt Services gt Apache2 2 and make sure the status is Started Step 2 Port for web server in management PC is occupied by other service Check if the port for web server is used by other service or not If yes please release the port of that particular service and assign another port for it Step 3 Port for web server is added in the firewall of management PC Check if the port is added in the firewall If not please add and enable the connection in the firewall Please refer to user manual lt 5 2 gt P71 www RackmountMart com Part XI Optional Accessories TE s 4425 Temp Humid Sensor Temp Sensor cx Water Sensor One sensor for temperature amp humidity Low profile and light weight design with a magnetic base for easy affixing to cabinet Part no EMS 102 2 with 2M cord EMS 102 4 with 4M cord why Smoke Sensor Safely operated smoke detection Part no EMS 201 1 with 1M cord EMS 201 3 with 3M cord Inductive Door Sensor Light weight mini size amp adhesive e No custom cutting required on doors Easy for existing cabinet retrofit or integration to new cabinet Part no EMS 502 2 with 2M cord EMS 502 4 with 4M cord Detection for temperature Low profile and light weight design with a magnetic base for easy affixing to cabinet Part no EMS 101 2 with 2Mcord EMS 101 4 with 4M cord ft Shock Sensor Al
36. ator and create a new one A new user login password 18 required Kenny Wong Operator 01 William Wong Operator 02 Operator 03 i L1 L3 s si Operator 4 Apply Cancel P 38 www RackmountMart com lt 5 1 gt System Setup In lt Setup gt page administrator can Activate max 30 Master IP groups Set the group command password Enable disable the EC box levels Step 1 Activate Master IP group 01 Step 2 Input IP address amp password of the IP dongle Step 3 Enable Command password Step 4 Input New command password Default is 00000000 Step 5 Input new command password in Confirm new password again Step 6 Click Apply to finish the Master IP group setup Step 7 Enable the EC box connected to the Master IP group Step 8 Click Apply to finish the EC box setting Step 9 Repeat step 1 to 9 for other Master IP groups if necessary Master iP groups OT G SS Men E Mon 87 pan pan man man man ES Initially please setup the Master IP one by one Master IP group Activate El Deactivate DO NOT activate the group if there is no any Master EC box connection Each Master IP group supports up to 16 EC boxes 1 Master EG box amp 15 Slave EC boxes IP dongle setting IP dongle address IP dongle password Firstly enter the IP Setup utilities to make the change ref to User Manual Master IP configurat
37. cation Status Location Status 2013 08 16 15 36 29 Rack_002 Rear_Top Closed Front_Top Opened 2013 08 16 15 26 28 Rack_002 Rear_Top Closed Front_Top Opened 2013 08 16 15 16 27 Rack_002 Rear_Top Closed Front_Top Opened 2013 08 16 15 06 26 Rack_002 Rear_Top Closed Front_Top Opened 2013 08 16 14 56 25 Rack_002 Rear_Top Closed Front_Top Opened 2013 08 16 14 46 24 Rack 002 Rear Top Closed Front Top Opened 2013 08 16 14 25 20 Rack_002 Rear_Top Closed Front_Top Opened 2013 08 16 14 15 18 Rack_002 Rear_Top Closed Front_Top Opened First Previous 1 2 3 4 5 6 7 8 9 10 Next Last Last 2000 log records Press F11 to enlarge or diminish the screen P61 www RackmountMart com Part VII Events Log Report lt Report gt provides monthly report for EC box log PDU log PDU Outlet log PDU TH sensor log Daily kWh log PDU Daily kWh log PDU outlet dii i Kan eee a in CSV format Please take the following steps to export the log category you want Step 1 Select the category period and target Period Year Month Target Ml EC box log 2013 1 v Master IP group Di PDU log Box level 01 PDU outlet log PDU TH sensor log Daily kh log POU Daily KW log POU outlet Fan unit log Fan unit fan log Door sensor log Device event Save new data Gancel new data input Step 2 Click Apply and Click OK from the pop up window It takes a few mins to complete P 62 w
38. ch for Unit CFM Setting daisy chain level setting Gsssossosesveseooocoe Individual fan status Buttons for Alarm Individual fan On Off buttons Temp Setting Temp LED display o O OQ QAJOOQQ 689005 099000 RA A s dier GORDON rU URES CAN S RCS Temp port bundled w a temp sensor QQQ SSTV0O STO TEMP LINK OUT 6 Daisy chain LINK port for connecting to the out port of the last level fan unit ky A D 0 e a Mo Aj D C es A Aj Q W NY OQ NV NA a zs Le si Q Q O Sou Daisy chain OUT port for connecting to the link port of the next level fan unit 7 S 7 S e e e e O SLA 5 FEN d e KA e C e N S S 59 CH LE Z e PO e ew HE SR C A 4 e d i ls d dac c9 SER Q9 CILS CUO 719 99 SOS m SET cer se 2 e eo se 3 Lo Cf E 2a DA Va ER SS A a 7 O li 4 P 26 www RackmountMart com lt 3 2 gt Fan Unit Model RA4017 6 R Side View 42 9 mm Front View 195 mm WW 997 L FE CE REACH TEMP LINK o OG 33U Door Mount Fan Panel with 6 fans Top View 195 mm 4 DIP switch for daisy chain level setting HHH ALAN Ls Temp port bundled w a temp sensor 6 Daisy chain WINK port for connecting to the out port of the last level fan unit 2 Daisy chain OUT port for conn
39. d Auta CFM cantro m Disable WI Enable 3 However the buzzer will sound if the temp CAN NOT drop under alarm temp MINUS 2 C within 10 mins Reading 24 2 Alarm Setting 35 0 Rising Alert Setting Apply Save new data Cancel Cancel new data input Exit Return to FAN UNIT SETTING P55 www RackmountMart com lt 6 5 gt Door lt Door Status gt provides a scan function to monitor the door sensor status based on Master IP group Door Status Master IP group no D Location Setting Location Status Location Status Location Status Location Status Rack_001 i Front_Top_001 Closed Rear_Top_001 Closed Front_Top_002 Closed Rear_Top_002 Closed Rack_004 d Level5 a Front Top 005 Auto data refresh COCCCCCCCO Press F11 to enlarge or diminish the screen In lt Door Setting gt user can change Location of door sensor amp Click Apply to finish the settings Door Setting Stalus Connected Mame Level Locallon Rack 001 DA DZ Location Front Top 001 Location Rear Top 001 Status Closed Status Closed D3 D4 Location Front Top O02 Location Rear Top 002 Status Closed Status Closed S verine a Cancel Cancel new data input Ex Retum to DOOR STATUS P56 www RackmountMart com Part VII Events Log Report lt Event gt provides past 2000 events of the following devices in an Master IP group EC box configuration amp connection sensor configuration amp con
40. ecting to the link port of the next level fan unit Individual fan status Individual fan On Off buttons Unit CFM Status LED Unit CFM fan speed Setting Buttons for Alarm Temp Setting P7 www RackmountMart com lt 3 2 gt Fan Unit Model RA4017 9 R Front View Side View 195 mm 42 9 mm WLU 997p FE CE REACH 33U Door Mount Fan Panel with 9 fans 4 DIP switch for daisy chain level setting G Temp port bundled w a temp sensor 6 Daisy chain LINK port for connecting to the out port of the last level fan unit TEMP LINK Daisy chain QUIT port for connecting O Q to the link port of the next level fan unit Individual fan status Individual fan On Off buttons Unit CFM Status LED Unit CFM fan speed Setting P 28 www RackmountMart com lt 3 2 gt Fan Unit IP Remote Access Not available must be via Master IP fan on the 1st level Daisy Chain Level 2nd to 16th level Temperature Port 1 x temperature sensor port sensor bundled Temperature Sensor Measurement Range 0 to 99 9 C Measurement Accuracy 1 5 100V or 240V AC at 50 or 60Hz via IEC type cord 20W 40W 60W 40W 60W I Operating 0 to 50 C Environmental Conditions 5 to 60 C Relative Humidity 90 non condensing 50G peak acceleration 11ms half sine wave Vibration 58 100Hz 0 98G 11ms cycle SERERE Mode Product Dimension RA4015 3 R 480 x 298 3 x
41. er to 4 2 Master IP Configuration Step 2 Open the Internet Explorer I E version 8 0 or above Step 3 Enter the configured IP address of EC 300M master box into the I E address bar Default IP address is 192 168 0 1 Step 4 Enter Login name amp Password Default login name amp password are 00000000 Login name Password a P 64 www RackmountMart com Part VIII SNMP Step 5 Select SNMP from the left navigation pane Step 6 The SNMP Settings window appears as below SNMP SNMP agent Enable Disable SNMP polling Read community public Write community private SNMP traps Trap Management station Station IP 138 168 2 225 Trap part Trap community Cancel Step 7 Click Enable in SNMP Agent to start the SNMP agent service Step 8 Input Read Community Default is public Step 9 Input Write Community Default is private Step 10 Select disabled or V2Trap in SNMP Traps A If select V2Trap please input IP address of the SNMP management station in Station IP Step 11 Click Apply to finish the SNMP settings P 65 www RackmountMart com Part IX FAQ 1 What is IGM 03 IGM 03 is a FREE environmental sensor management software to monitor up to 30 Master IP Groups remotely max 16 box levels in each Master IP Group tot
42. ert the physical vibration on the cabinet Part no EMS 301 1 with 1M cord EMS 301 3 with 3M cord Mechanical Door Sensor amp Low cost Precise Cost efficient integration to new cabinet Custom cutting required on door Part no EMS 501 2 with 2M cord EMS 501 4 with 4M cord Fluid leakage detection 5M rope round the cabinet bottom to detect any fluid flowing to the cabinet area IP65 cable joint connectors provided Part no EMS 401 3 with 3M cord f LED Beacon e Highly visible for alerting user to alarm status Part no EMS 602 1 with 1M cord EMS 602 3 with 3M cord Q LED Light Bar e Auto ON OFF by door sensor detection e Manual ON OFF by software remote e Magnetic base for easy affixing to cabinet Dimension W x D x H 20 x 300 x 12 mm Part no EMS 601 2 with 2M cord EMS 601 3 with 3M cord The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2013 Synergy Global Technology Inc All rights reserved P 72 www RackmountMart com
43. es with Temp amp Humid sensor port x 2 W series monitored PDU WS series switched PDU WSi series outlet level measurement switched PDU A Please visit below link to select desired PDU amp call for the PDU drawing amp specifications http www rackmountmart com html odu kwh htm EM 1001 oor SEE Ee EI ERI BABA BEBE HB AR SAN BH 1 2 3 4 Smoke Shock 1 Lamp 2 Alarm T1 T2 Cat 5 6 cable Up to 20M LINK OUT LINK OUT LINK OUT LINK OUT oaooooaon kannon Ca Be moon eS sussssonna L anan C DANDAN onamni mn TITT Cat 5 6 cable mi mi Cat 5 6 cable TI TITT Cat 5 6 cable mui tonni Up to 20M Up to 20M Up to 20M an A Infra Power Infra Power Infra Power Infra Power 1st level 2nd level 3rd level 4th last level PDU meter PDU meter PDU meter PDU meter A Max daisy chain distance from EC box to the 4th PDU up to 80M PDU level setting Step 1 Press the A amp V button to display no 9 and press M to confirm Step 2 Press the amp V button to PDU ID and press M to confirm Step 3 In display 9 1 Press the A amp Vv button to select PDU level no amp press M to con
44. firm Display 9 1 Step 4 Press to exit A For details about PDU level setting please refer to IPM 03 user manual lt 3 1 gt http www rackmountmart com dataSheet IPM 03 pdf P21 www RackmountMart com lt 3 2 gt Fan Unit Under EM 1001 network each Box supports RA4015 RA4017 remote fan unit x 4 in a daisy chain Each fan unit comes with TEMP sensor port x 1 EM 1001 1st level 2nd level 3rd level Fan unit model Fan unit model Fan unit model Gms ME AT Mi Mi HM Cat 5 6 cable Cat 5 6 cable LINK OUT Up to 20M LINK OUT Up to 20M LINK Cat 5 6 cable Up to 20M LINK A Max daisy chain distance from EM box to the 4th fan unit up to 80M 4th last level Fan unit model P22 www RackmountMart com lt 3 2 gt Fan Unit ON ON ELLI gg NE OFF Fan unit level setting Using the dip switch no 1 2 3 4 5 6 amp 8 to setup each FAN unit level as below No 7 dip switch only for audio alarm setting Using the dip switch no 7 to setup each FAN unit audio alarm as below Dip switch 7 AN If enable the audio alarm the buzzer will sound when the outside temperature is over the preset alarm temperature P 23 www RackmountMart com lt 3 2 gt Fan Unit Model RA4015 3 R 1U Fan Tray with 3 fans FE CE site n e Unit CFM Status LED O D
45. hedule VZ4C13 3DA W SI VZ4C13 3DA WSI V24C13 3DA WSi a n mon outlet name 04 outlet name 02 outlet name 03 outlet name 04 outlet name 05 outlet name 06 outlet name 7 outlet name DB outlet name 098 outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name 19 outlet name 20 outlet name 21 outlet name 22 outlet name 23 i i ka E TION outlet name 01 outlet name 02 outlet name 03 outlet name 04 outlet name 05 outlet name 06 outlet name O07 outlet name 06 outlet name 09 outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name 19 outlet name 20 outlet name 21 outlet name 22 outlet name 23 BEB e m i2 2 2 9 9 E LA du or m outlet name 01 outlet name 02 outlet name Id outlet name 04 outlet name 05 outlet name Df outlet name Dr outlet name 06 outlet name _09 outlet name 10 outlet name 14 outlet name 112 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name A189 outlet name 20 outlet name 21 outlet name 22 outlet name 23 Wk ra gm M i am m m m Lu m m gm m outlet name 1 outlet name _ 02 outlet name 03 outlet name 04 outlet name 05 outlet
46. ion 192 168 1 583 fthe administrator wants to change IP address and password two steps are required Secondly return to this page to make the same change on IP address and password IP dongle group Command password Default command password is 00000000 New command password Administrator may set command password for Master IP groups one by one Confirm new password Command password required for any EC box configuration and control Administrator can set different command password far different Master IP group or all Master IP groups share the same password EC Box Setting Level 01 E Disable Level 09 Enable Level 02 W Disable Level 10 Level 03 Disable Level 11 Level 04 MI Disable Level 12 Level 05 Disable Level 13 Enable Enable Enable Enable Level 06 Disable Level 14 Level 07 Disable Level 15 Enable Enable BER RD m Re s s Level DE Disable Level 16 Enable Save new data Cancel new data input P 39 www RackmountMart com lt 5 1 gt System Setup In lt Alarm gt administrator can configure the alarm email server amp max 5 email recipients to receive alarm notifications from the software Step 1 Enable alarm email Step 2 Input SMTP server SMTP port Step 3 Input sender email account in User email Step 4 Input sender name in User name Step 5 Input sender email account password in Password Step 6 Input the
47. ircuit A Circuit Date Time Model Location kWh kWh 2013 06 20 00 00 00 V24C13 32A WSI Rear Left 007 0 0 0 0 2013 06 18 00 00 00 V24013 32A W5i POULocation First Previous 1 f8 9 10 Next Last Last 2000 bog records Press F11 to enlarge or diminish the screen p 59 www RackmountMart com Part VII Events Log Report lt Daily kWh log PDU outlet gt provides past 2000 daily energy consumption log records of each PDU s outlet The record is logged at 00 00 everyday 5 mins for previous day Outlet level PDU models only The PDU outlet kWh log will not be recorded at 00 00 if the PDU connected is less than 24 hours Daily kWh log PDU outlet Box level 01 PDU level 0 Outlet level 01 Date Time Model Location 2013 06 20 00 00 00 00 00 00 NZACII IZA WSI Rear Left_001 2013 06 18 MV24013 32A VVSI POULocation First Previous 1 7 amp 9 10 Next Last Last 2000 bog records Press F11 to enlarge or diminish the screen lt Fan Unit log gt provides past 2000 log records of each Fan unit The software will generate a Fan unit log record in every 10 mins Fan Unit log Box level 11 I Fan Unit level 01 f n C Date 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 Time 12 09 43 11 59 42 11 40 40 11 30 39 11 07 07 10 48 35 10 38 34 10 28 33 10 14 59 First Previous 1 Name FanNamed1 F
48. l Operating 20 to 60 C Degree 20 to 60 C Degree 30 to 70 C Degree Relative Humidity 5 90 non condensing 52W x 22 5L mm Dimensions Product 32 5L x 12 2W x 9 2H mm with metal plate Inductive door sensor i Mechanical door sensor with 2m cable 2mm Adhesive tape Metal plate Compatibility EM 1001 1002 only Safety Regulatory FCC amp CE certified RoHS2 8 REACH compliant Supply includes Environmental P 10 www RackmountMart com lt 2 2 gt Door Sensor Optional door sensor is an essential accessories as users can be alerted by visual and audio alarm for unauthorized access Inductive Door Sensor pair EMS 502 2 Features e light weight adhesive e mini size 32 5 x 12 2 x 9 2 mm e no custom cutting required on door Front View Side View Package content e Inductive sensor w 2m cable x 2 e 2mm adhesive tape x 6 Ar Requirements A e cabinet frame made of ferrous metal iron e sensing distance 3mm P 11 2mm adhesive tape www RackmountMart com lt 2 2 gt Door Sensor Installation steps connect to the EM 1001 1002 guide amp fix the cable with cable clips place the sensor at the top of the door close to the opening side Suggested sensor position to EM box fa adjust the sensor with adhesive tape to ensure the sensing distance between door to frame within 3mm while door in close status Sensor Operation DOOR CLOSE
49. larm amp Rising alert amp amp Low alert amp of PDU s circuits Click Apply to finish the above settings Click Reset to reset peak amp or kWh of PDU s circuits Click ON OFF to switch On Off outlet Switched PDU models only View On Off status of outlets View aggregated current on the PDU View lastest loading amp energy consumption of outlets Outlet level measurement PDU models only View the lastest T TH reading connected to the PDU PDU kWh PDU load amp Power factor Apparent power KVA gt Circuit B 2013 07 18 14 23 53 2013 07 18 14 29 34 Amp 0 0 0 ON OF x s outlet name 13 00 70 30 f 00 0 0 0 ON OFF s outlet name 14 00 10 00 00 0 0 ON OFF outlet name 15 00 10 00 DO 0 0 ON f s outlet name 16 0 0 1 0 00 00 0 0 DI Fi FA outlet name 17 00 10 00 0 0 outlet name 18 0 0 1 0 0 0 0 outlet name 19 0 0 VA ou Md outlet name 20 0 0 1 00 00 Outlet name 21 0 0 0 0 0 0 outlet name 22 0 0 1 0 0 outlet name 23 G outlet name 24 Click outlet icon for setting P 47 www RackmountMart com lt 6 3 gt PDU In lt Outlet Setting gt user can Change Name of outlet Change Power up sequence delay of outlet Switched PDU models only Change Alarm amp Rising alert amp amp Low alert amp of outlet Outlet level measurement PDU models only
50. le secure it with bundled mounting screws 6 32x4 5mm x 2 Jin Sensor Operation DOOR CLOSE DOOR OPEN close door open door Sensor button is pressed on Sensor button is released DOOR CLOSE SIGNAL sends out DOOR OPEN SIGNAL sends out Door Cabinet E Cabinet frame frame frame OPENED j j B n rel Actuation distance gt 3mm utton released Physical touch required P14 www RackmountMart com lt 2 3 gt Temp amp Humidity Sensor Each EM box provides Temp amp Humid Sensor port x 2 If more TH sensors required two temp amp humid sensor ports on each integrated PDU can be applied Fe cc BEACH Temp amp Humid Sensor Part no Temperature Range 0 to 80 C 32 to 176 F SONS Accuracy 0 5 C typical 1 F 1 C 42 F Resolution 0 1 C 0 2 F Response Time 5 to 30 sec Relative Range 0 to 100 R H Humidity A you ccuracy 0 to 100 8 0 R H SAS 20 to 80 4 5 R H Resolution Response Time Power Voltage 12VDC powered by sensor port Power consumption 0 24 Watt Housing Chassis amp Cover Color Dark gray Installation Magnetic base for unrestricted installation Connection Gabi eng TH sensor w 2m cable standard T sensor w 2m cable standard g TH sensor w 4m cable option T sensor w 4m cable option Cable Specification 4 wired 3 5mm to RJ11 Environmental Operating 0 to 80 C Degree Storage 5 to 80 C Degree Humidity 0 100 non condensing Dime
51. levels B The ist level EC box must be EM 1001 B 1x EM 1001 allows access to 16 levels H For remote access simply connect 1 x EM 1001 B The 2nd 16th level boxes must be EM 1002 1st level 2nd level 3rd level EM 1001 EM 1002 EM 1002 LAN OUT LINK OUT LINK OUT MENU Cat5 6 cable Cat5 6 cable max 20 meters max 20 meters 7 A Max distance in a daisy chain group up to 300M To LINK port of next level EM 1002 Qh p max level 16 pe To Network Device for IP Access via WAN P7 www RackmountMart com Part Il Sensor Installation amp Specifications lt 2 1 gt Overview li ee a EM 1001 1002 Smoke Shock 1 Lamp 2 Alarm 7 7 7 CJ LI LI L L i a a a TH SENSOR P 8 www RackmountMart com lt 2 1 gt Overview Door Sensor LED Beacon gw c lont Bar le a SA TH Sensor Shock Sensor lt gt Co 7 A P Water Sensor P9 www RackmountMart com lt 2 2 gt Door Sensor amp FE CE REACH A i a Inductive Door Sensor Mechanical Door Sensor Part no 502 20 EMS5012 Sensitivity Actuation Operating Force Sensing distance Max 3mm mevi idist leue Voltage 12VDC powered by sensor port Current Consumption 100mA Connection Cable Length sensor w 2m cable standard sensor w 4m cable option Environmenta
52. n Name Action 01 Rack 001 OutletSchedule 1 Daily Disabled Disabled OutletSchedule 2 Daily Disabled Disabled 02 Rack 002 OutletSchedule 1 Daily Disabled Disabled OutletSchedule 2 Daily Disabled Disabled 03 Rack 003 a OutletSchedule 1 Daily Disabled Disabled OutletSchedule 2 Daily Disabled Disabled Auto data refresh IOIO Press F11 to enlarge or diminish the screen Step 2 In lt Outlet Schedule Setting gt page Select Oultet schedule 1 amp Tick Enable Step 3 Provide the name of the outlet schedule Step 4 Select the action either ON or OFF Step 5 Select the time for outlet schedule 1 E Disable Enable OutletScheduled1 Outlet schedule Name Action E ON Daily ON OFF Schedule Time Weekly One Time 00 m 24 hours format Outlet schedulg LEZ E Disable Name QutletSschedule01 Action ON Weekly ON OFF Schedule E Daily Sun 00 00 v Time UEA E Disable OutletSchedule01 OFF E ON E Daily E Weekly iWlione Time 01 m 01 MM DD date format 00 00 24 hours format 4 p 52 www RackmountMart com Outlet schedule Name Action One time ON OFF Schedule Time lt 6 3 gt PDU Step 6 Tick the outlets of the connected PDU s to switch ON OFF based on the action you selected Outlet sc
53. name 6 outlet name 7 outlet name Ds outlet name 09 outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name 19 autlet name 20 outlet name 21 outlet name 22 outlet name 23 a ra m CE DBO outlet name 24 ui outlet name 24 outlet name 24 outlet name 24 Apply Save new data Cancel Cancel new data input Exit Return to OUTLET SCHEDULE Step 7 Click Apply to save the settings Step 8 Repeat step 2 to 7 for Outlet Schedule 2 to 6 if necessary d lf the outlet schedule task is One Time that specific task will be disabled automatically once the action is completed To cancel the outlet schedule tick Disable amp Click Apply to finish the changes P53 www RackmountMart com lt 6 4 gt Fan Unit lt Fan Unit Status gt provides a scan function to monitor the Fan unit status based on Master IP group Fan Unit Status Master IP group no Page 1 Box Fan Level Unit Model Location No of fan CFM gi Fi RF 1 3 1U Fan Tray FanLocation0 1 Max F2 RF 1 31U Fan Tray FanLocaticn03 L Max Auto data refresh DODO LITIO Press F11 to enlarge or diminish the screen In Fan Unit Setting gt user can Change Rack amp Position amp Click Apply Switch ON OFF fan unit Change fan unit CFM
54. nection PDU configuration amp connection PDU s outlet 8 TH sensor configuration Fan unit configuration amp connection Fan unit Temp sensor configuration First Previoua 1 2 3 4 5 17 naxt 1 Last Time Event Description 11 49 41 Fan Unit Tamp connection Tamp Sensor reconnection Box level 01 Fan Unit level 01 Sensor 01 11 45 24 12 dongle connection IP dongie disconnection IP dongie group 02 2013 0620 11 08 35 Box configuration admin Change EC Bax location Bax Javel DE 2013 0520 11 02 14 Door configuration admin Change door location Box level 01 Door 2013 06 20 11 01 28 Door configuration admin Change door location Sox level 01 Door 2013 06 20 11 01 46 Door configuration admin Change door location Box level 01 Door 2013 05 20 10 57 06 Fan Unit Temp connection Tamp Sensor reconnection Box level 01 Fan Unit level 01 Sensor 71 2013 05 20 10 35 01 iP gongle connecton IP dongle disconnection IP dongia group 02 2013 06 20 10 43 14 Door configuration admin Change door location Box level 01 Door 2013 06 20 10 47 14 Door configuration admin Change door location Sax level 05 Door 2013 06 20 10 45 40 Door configuration admin Change door location Box level 01 Door Master IP connection PDU connection EC box configuration EC box s sensor configuration 3 Discunnection Disconnection Enable Gisable L box 4 L Change door sensor location 2 Reconnection Z
55. nsions 30L x 25W x 18H mm Weight Net Tempettitue Sensor 4 wired 3 5mm to RJ11 cable 2m black color Compatibility W WS Wi WSi series PDU X 2000 series Supply includes EM 1001 1002 Safety Regulatory FCC amp CE certified Environmental RoHS2 8 REACH compliant P 15 www RackmountMart com lt 2 4 gt Smoke Sensor Smoke sensor comes with a RED LED When smoke alarm triggers the RED LED lights on with beep sound continuously ua FE CE VA REACH oHS Part no Smoke Sensor Sensitivity Smoke sensitivity 0 15 0 3 dB m Alarm Output 24VDC 1A Continuous beeps vdi Mi Voltage 12VDC powered by sensor port Current Consumption 200uA Power ON LED Red LED flashes every 6 seconds Housing Chassis amp Cover ABS plastic Connection Cable Length 1m 3m option Environmental Operating 5 to 50 C Degree Humidity 5 9095 non condensing Weight Net 165g Supply includes 1 Smoke Sensor with 1m cable Compatibility X 2000 series EM 1001 1002 Dimensions Safety Regulatory FCC amp CE certified Environmental RoHS2 8 REACH compliant P 16 www RackmountMart com lt 2 5 gt Shock Sensor Shock sensor comes with a RED LED When shock alarm triggers the RED LED lights on continuously FE CE REACH SOCK Sensor EMS Part no Adjustable sensitivity Internal micro knob with screwdriver cross slot Alarm Output Solid State Relay 12V
56. ollowing 3 software component s are required to run InfraGuard Manager 1 Apache 2 2 Please decide to use the existing or new Apache 2 2 C Use existing Apache f Install new Apache 2 2 Tick this if the management PC has been already installed Apache Folder CiAppServi Port 2 If the port of web server 2 PHP 5 Please decide to use the existing or new PHP 5 is not 80 please input the C Use existing PHP f Install new PHP 5 appropriate no here and Tick this if the management PC has been already installed PHP Folder CMppse follow the instruction in Pr Change port no of web server next page to make 3 PostgreSQL 9 0 Please decide to use the existing or new PostgreSQL 9 0 the change effective C Use existing PostgreSQL Tick this if the management PC has been already installed PostgreSQL C Program Files Postgre SQL 9 PostgreSQL login postgres PostgreSQL password 1gaz2WSX A PostgreSQL password can be changed by user The password MUST contain at least three of the following four character groups English uppercase characters A through Z English lowercase characters a through z Numerals 0 through 9 Non alphabetic characters such as Yo P 35 www RackmountMart com 4 7 Change Port no of Web Server A lf users want to use another port no instead of 80 please take the following steps after InfraGuard Manager IGM 03 First time
57. ountMart com 2 Howcanlgeta further support Please send an email to support rackmountmart com or sales rackmountmart com P 67 www RackmountMart com Part X Troubleshooting EC Box Disconnection 1 GUI shows a certain level EC Box disconnected Step 1 EC Box power off Check the EC Box is power ON or not Step 2 EC Box level setting duplicated in the same Master IP group Check and make sure EC Box level is unique and not duplicated in the same Master IP group Please refer to user manual lt 1 5 gt for details A The other EC box with same level shows Searching in lt Overview gt page Step 3 This level EC Box is enabled in lt Setup gt page but not connected to the daisy chain Make sure to enable the EC Box in lt Setup gt page ONLY when it is connected to the daisy chain 2 GUI shows from a certain level EC Box to the last one disconnected Step 1 Cable disconnected loose or defective Check the Cat 5 6 cable connection between the first disconnected EC Box and the previous one Make sure the connectors are firmly attached And check if any defects on your cable or not If yes replace a new one Step 2 The first disconnected EC Box failed Unplug the Cat 5 6 cable on the first disconnected EC Box then plug it to the second disconnected EC Box to check if the problem caused by the first disconnected EC Box 3 GUI shows the whole group of EC Boxes disconnected Step 1 C
58. poeta Global Technology Inc NI www RackmountMart com Toll Free 1 888 865 6888 Tel 510 226 8368 Fax 510 226 8968 Email sales RackmountMart com User Manual EM 1001 1002 Environmental Control Management Software A E mi FE CE REACH www RackmountMart com Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference B Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth B Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit B When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing dam age to other equipment or injury to persons nearby B When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating HM Arrange the equipments power cord in such a way that others won t t
59. r operation Otherwise daily data backup will NOT be proceeded P 32 www RackmountMart com lt 4 4 gt Supported OS Platform amp Language Software Management IGM 03 supports the OS platforms amp languages as below MS Windows 7 Professional with SP1 English Edition MS Windows 7 Ultimate with SP1 English Edition MS Windows 8 Professional 32bit amp 64bit English edition only MS Windows Server 2003 R2 Standard Edition with SP2 English Edition MS Windows Server 2008 Standard Edition SP2 English Edition MS Windows Server 2008 R2 Standard Edition SP1 English Edition A Make sure users login the management PC as a member of Administrator Group before IGM 03 installation amp execution User can select the following languages under Control Panel gt Region and Language in English Edition OS 1 Arabic Saudi Arabia 2 Chinese Traditional Hong Kong S A R 3 Dutch Netherlands Sa SS Ss isi 4 English Australia A Format 5 English United Kingdom English United Kingdom 6 English United States 7 French France Date and time formats 8 German Germany short date dd MM yyy si 9 German Switzerland Long date dd MMMM yyyy vi 10 Italian Italy Short time 11 Japanese Japan Long time HHimmiss 12 Korean Korea First day of week Monday 4 13 Norwegian Norway What does the notation mean 14 Portuguese Portugal Examples 15 Russi
60. rement PDU Outlet Schedule Outlet Switch ON OFF Amp Alarm Threshold Setting Amp Rising Low Alert Threshold Setting Temp Humid Circuit Breaker Monitoring Fan Unit CFM amp Temp Monitoring Unit CFM fan speed Setting Auto CFM Control Setting Individual Fan Kit ON OFF Fan Unit ON OFF Event System amp Device Event Wo Device Log Reporting P 30 www RackmountMart com 4 2 Master IP Configuration Please take the following steps to configure the EM 1001 Step 1 Prepare a notebook computer to download the IP setup utilities from the link http www rackmountmart com downloads html Step 2 Double Click the MasterlPsetup msi and follow the instruction to complete the installation Step 3 Go to each Master box with the notebook computer amp a piece of CAT 5 6 cable to set up the IP configuration by IP setup utilities as below Please take the procedures for all Master boxes ONE BY ONE Master box EM 1001 CAT 5 6 cable To notebook computer To LAN port LAN port Ensure the Master box in power ON status Reconnect the Master box with the network device router or hub after finish master IP configuration Infra Guard Environmental Sensor Solution Master EC box Configuration Device MAL address 00 0D 5D 05 BC 1A Name Name __ Fea 1 Location Rack 001 Password New password Confirm new password IP address 192 168 0 1 Subnet mask 255 255 255 0 for
61. ring amp Setting lt 6 1 gt Devices Overview lt EC Box Overview gt provides a scan overview on the status of sensors PDUs fan units amp doors based on Master IP group Master IP groups _01_ ati Nesti f4 fos fos our ea er Ga into Ba pa ag Ec KI Et ia 70 n 2 j 22 25 ETENEE 28 AN EC Box Overview Master IP group no 01 Master Box name default box name Master Box IP address 192 168 1 83 Box Fan Unit Level Location F2 F3 F4 Rack_001 v SS Rack_002 v I FI E E m S amp S Rack 003 wv Auto data refresh OLIOLI VEDI TI TH2 Press F11 to enlarge or diminish the screen Smoke Shock 1 Smoke Shock 2 In EC Box Device Setting user can disable or enable T TH sensor Smoke Shock sensor Water sensor Door sensor PDU Fan unit LED light bar Click Apply to finish the above settings A DO NOT devices if not connected EC Box Setting Box level 01 Status Connected Name Level6 Location Rack 001 Sensor Sensor Ti TH 1 Disable V Enable s7 Lamp1 Disable W Aways OFF D Always ON El On Off by Door Sensor D1 D2 TITH2 4 Disable C Enable S8 Lamp2 E Disable 4 Always OFF D Always ON El On Off by Door Sensor D3 D4 Smoke Shock1 Disable Enable Smoke Shock2 E Enable Water 1 E Disable V Enable Water 2 W Disable Enable 51 S6 sensor audio and visual output 9 Box level
62. rip or fall over it B If you are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labelled on the equipments electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipments ratings label B Observe all precautions and warnings attached to the equipment B If you dont intend on using the equipment for a long time disconnect it from the power outlet to prevent being dam aged by transient over voltage B Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock B Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invali date its warranty B If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover B Any product on which the serial number has been defaced modified or removed B Damage deterioration or malfunction resulting from Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product LI Repair or attempted repair by anyone not authorized by us Any damage of the product due to shipment Removal or installation of the product Causes external
63. sing alert Change tuman alara Change rising alert sap Change himis rising alert Change low alert anp Reset peak amp w date ane Case Li Reset k w date ara tine 9 Aap alarm 10 Aap citing alert 10 Homid riting alert 11 Asp lov alert 13 Asp nersal Change TH location Tesp slara Teng rising atert Huxid alarm Change POU location asp siare rw gt WC da t w w 1 2 3 4 5 6 7 b e v lt e OW OT b od di ka amp 9 Asp rising alert 10 Aap low alert 11 Asp corneal 12 Circuit breaber tripped return to noreal Fan unit configuration Fan unit s temp sensor configuration 1 Change unit nane 1 Switch fan on p 1 Activate Cesctivate temp sensor Enable disable auto CEM control Change teng alan 2 Change unit location 42 Fan failure normal Change tenp rising alert 3 Change umit CEN Change teng location Tesp alam Tenp rising siert Teng ner al Mon mw d te P 57 www RackmountMart com Part VII Events Log Report lt EC Box log gt provides past 2000 log records of each EC box in a Master IP group The software will generate an EC box log in every 10 mins EC box log Box level Date 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 2013 06 20 01 v Time 07 25 42 07 15 41 07 05 40 06 55 39 06 45 38 06 35 37 Location Rack_001 Rack_001 Rack_001 Rack_001 Rack_001 Rack_001
64. to the product such as electric power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear L Any other causes which does not relate to a product defect B Removal installation and set up service charges Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures B Re position or relocate the receiving antenna B Increase the separation between the equipment and receiver B Connect the equipment into an outlet on a circuit different from that to which the receiver is connected www RackmountMart com Before
65. ww RackmountMart com Part VII Events Log Report Step 3 Right Click the file name below and SELECT Save target as to download the log file Category l EC box log PDU loa POU outlet log POU TH sensor log Daily kWh log PDU l Daily kWh log POU outlet LI Mr pen Fan unit log Open in new tab Fan unit fan log Open in new window E Door sensor log Save target as E Device event Print target Cut Save new data Copy Cancel Cancel new data input Copy shortcut Paste All Accelerators 4 di To download the file please 1 Right click the file link below Add to favorites 2 Select Save targetas to download the file Send to OneNote stig ST E M aM a cranio see ni ete TI Properties Step 4 Click Close to complete or Open to view the content of log P63 www RackmountMart com Part VIII SNMP The EM 1001 master box can manage the connected EM 1002 slave box in a single daisy chain up to 16 levels via SNMP v2c Simple Network Management Protocol A Only EM 1001 master box can support SNMP 1 Accessing MIB Files Use the World Wide Web WWW to download the SNMP MIB file at this URL http www austin hughes com support utilities infraguard IGM MIB mib 11 Enabling SNMP Support The following procedure summarizes how to enable the EC 300M master box for SNMP support Step 1 Connect the EC 300M master box to a computer Please ref
66. x pp om cp pb n ry pg psp pb pmi m m ul i en Ek V24013 30A WSI outlet name 01 outlet name 02 outlet name 03 outlet name 04 outlet name 05 outlet name Df outlet name Q7 outlet name 08 outlet name Wd outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name 19 outlet name 20 outlet name 21 outlet name 22 outlet name 23 outlet name 24 V240C13 30A WSi outlet name 01 outlet name 02 outlet name 03 outlet name 04 outlet name 05 outlet name Df outlet name Of outlet name 08 outlet name 03 outlet name 10 outlet name 11 outlet name 12 outlet name 13 outlet name 14 outlet name 15 outlet name 16 outlet name 17 outlet name 18 outlet name 19 outlet name 20 outlet name 21 outlet name 22 outlet name 23 outlet name 24 www RackmountMart com lt 6 3 gt PDU PDU outlet schedule is a function allowing users to set a specific time to switch either ON or OFF the outlets on daily weekly or one time basis Each box provides 6 schedule tasks Users can follow the steps below to enable the PDU outlet schedule Step 1 Go to lt Outlet Schedule Overview gt page Click Setting Outlet Schedule Overview Master IP group no 01 Page a 2 Outlet Schedule 1 2 Outlet Schedule 3 4 Outlet Schedule 5 6 OX Level Location Setting Name Action Name Actio