Home

Assembly Instructions English

image

Contents

1. English Assembly Instructions GSS Grundig SAT Systems STC 160 Head End Station SAT IF input distributor SID 162 Notes on the Assembly Instructions As well as this supplementary Assembly Instruc C 4 tions the Assembly Instructions for the STC 160 apply GSS Phone 49 0 911 703 8877 Grundig SAT Systems GmbH Fax 49 0 911 703 9210 Beuthener Strasse 43 Email into gss tv D 90471 Nuremberg Internet www gss tv Contents 1 Safety regulations SOHHHSHSHSHSHHSHHSHHSHHSHHHSHHSHHHHHHHHHHHHHSHSHSHSHSHSHSHHSHHSHHSHHHHHSHSHSHHSHHSHHHHHHHHHHSHHHHHHHHHHHHHHHHHHHHHSHHHEOO 3 2 General information SHHHSHHHHHHSHHSHHSHHSHSHSHSHSHSHHSHHSHHSHHSHHHHHSHHSHHHHHSHHHHSHHHHHSHHSHHHSHSHSHSHSHSHSHHHSHHHHHHHHHHHHHSHHHHHHHHHHHOLOE 3 Scope of delivery eee eee oe a ee ee ene ee 3 We Gia A ANG wages ce geseecre E 3 SCE DOM cea cc coment cece E ness EEEE ER enerene ee eesnee ess 4 3 O i i vervieWw SHHOHHHHHHHHHHHSHHSHSHSHSHHSHHSHSHSHHHHHHHSHHHHSHHHSHHHHSHSHHHHHHHHSHSHSHSHSHSHSHSHSHHSHHSHHSHHSHHHSHHHHSHHSHHHHHHHHHHHHHHHHHHHHHHHHHHHHHOO 4 Installing the SAT IF input distributor ccssccssssssssssscsssssssssscsssssssssssessssseses D 5 Connecting the SAT IF input distributor sssscccssssscsssssccessssccsssssscessssscesseees O 5 1 Connecting the HF Comme CHONG c 10eesaadcacsecssaancacvaccaucersaeieesopeaeiercaceseee es 6 5 2 Connecting the power SUPPIY ccccccceseesccceeseeseeeeeeeeeeeeesaeeeeeeesae
2. aali i af E e860 o0olo aojo eet CE EE E E E E E o O a ee aoe see ee ee ee f e Fasten the outer sockets of the SAT IF input distributor 3 according to fig 4 with two nuts and lock washers put under each a am tik na bane Fig 4 i Tighten the nuts until the teeth on the lock washers have penetrated the exterior coating and a good connection is made between the housing and the SAT IF input distributor 5 Connecting the SAT IF input distributor 5 1 Connecting the HF connections Connect the outputs and F fig 2 to the appropriate inputs of the modules Using one reception area loop through mode e Connect input D of the SAT IF input distributor with one of the pre installed F terminals 4 in the rear wall of the head end station fig 5 using a HF cable made on site length approx 30 cm Connect the loop through output C with input B using a HF cable made on site length approx 30 cm Fig 5 Using two reception areas e Connect inputs B and D of the SAT IF input distributor with the appropriate pre installed F terminals 4 in the rear wall of the head end station fig 6 using HF cables made on site length approx 30 cm Terminate the loop through output with the terminator 5 2 Connecting the power supply e Connect plug 6 of the cable of the LNB power connection A fig 7 to one of the con
3. eeeeeeas 7 6 Final d 8 ina proce ures SHHHHHHHHHHHHHHSHHSHHSHSHHSHSHSHSHHSHHSHHSHHSHHHSHHSHSHSHHSHHHHSHHHHSHHSHHSHHSHHSHSHSHSHHSHHSHHHSHHSHHHHSHHHHHHHHHHHHHHHHHHHSOSOE 1 Safety regulations e Assembly installation and servicing must be carried out by an authorised electrician e Switch off the operating voltage of the system before beginning with as sembly or service work or pull out the mains plug of the head end station e Do not perform installation and service work during thunderstorms e Ensure that the device is adequately ventilated e Avoid short circuits For further information please read the safety regulations listed in the assembly instructions for the STC 160 head end station which pertain to this module 2 General information Scope of delivery 1 SAT IF input distributor SID 162 8 SAT cables 1 CD assembly instructions 1 Brief Assembly Instructions Mounting material Technical data The requirements of the following are met 73 23 EEC 89 336 EEC The product fulfils the guidelines and standards for CE labelling Frequency range 950 2150 MHz Decoupling of the outputs typ 20 dB Inputs 2 F sockets Input impedance 75 Q Loop through output 1 F socket Outputs 6 4 F sockets Output impedance 7350 Loss D gt E s Fig 2 9 14 dB Loop through loss D gt C typ 5 dB Loss B gt F 9 12 dB LNB operating voltage supply 12 V lt 800 mA total Description T
4. he SAT IF distributor SID 162 is equipped with two SAT IF inputs one loop through output and 10 SAT IF outputs This enables to distribute two reception areas to 4 and 6 SAT IF outputs Using the loop through output the reception area 1 can be distributed to the 10 outputs The F sockets of both reception areas are marked with different colours If the loop through output is not used it must be terminated using the terminator supplied The DC power feed of 12 V lt 800 mA is used for the power supply of the LNBs connected The SAT IF distributor SID 162 is designed exclusively for use in the STC 160 head end station 4 Fig 1 Overview aw aay tT ft fT f Fig 2 A LNB power connection D Input 1 Input 2 Outputs of input 1 D C Loop through output of F Outputs of input 2 input 1 D with terminator 4 Installing the SAT IF input distributor N Before installing or changing a module or accessory switch off the head end station or unplug the power cable from the mains power socket Installing the SAT IF input distributor take care that no cables are squeezed off or injured e Remove the front cover and the base plate of the STC 160 head end station see STC 160 assembly instructions e Insert the SAT IF input distributor 1 above the output collector 2 according to fig 3 so that the LNB power connection A is facing the control panel Pa See r a a aa r a a
5. tacts LNB power supply 12 V 800 mA total LNB power supply Fig 7 6 Final procedures N After installing the head end station retrofitting accessories or installing modules it is necessary to tighten all cable connections F terminals and cover screws in order to maintain compliance with current EMC regulations and to ensure a reliable operation e Securely tighten the cable connections F connector using an open ended spanner spanner gap 11 mm e Program the modules connected and the head end station if necessary e Position the breakthroughs in the base plate above the fastening screws 2 fig 8 e Push the base plate in direction of the arrow and lock it with the locking screw 1 e Tighten the fastening screws 2 Fig 8 e Tighten the nuts of retrofitted F terminals if applicable e Mount the front cover see STC 160 assembly instructions Alterations reserved Technical data E amp O E by GSS GmbH 08012008

Download Pdf Manuals

image

Related Search

Related Contents

Fiche 39 Les ateliers d`écriture au CP    Gembird CCA-417W  BUDgEt prIMItIf2015 - La ville de Joué-lès    Kenmore 9-Year Energy Guide  Supermicro X7DCL  取扱説明書 - トーヨーキッチン  Ignition Switches  

Copyright © All rights reserved.
Failed to retrieve file