1. limits for a Class A digital device pursuant to part 15 and 2 of FCC Rules and EN 55022 61000 3 for CE certification These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction guide may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Re orient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult a service representative for help Properly shielded and grounded cables and connectors must be used in order to comply with FCC CE emission limits Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment UL Statement This device has completed a UL Commercial Inspection and Testing Services for the multimode DVI cable complied with VW
2. 00 C to the SDI receptacle of a Display directly Do NOT recommend to use any intermediate cable or adapter between them It may deteriorate the signal transmission performance amp Figure 4 Rx module of SDIX 100 C Step 5 Power ON the SDI source and Display Note Both of Tx and Rx modules of SDIX 100 C must be connected by 5V power adaptors One 1 One 1 36 s01 _3G SDI Digital Video gt Digital Video input input Figure 5 Whole Connection of SDIX 100 C Step 7 If the system does not work properly go to page 1 5 trouble shooting 1 4 Installation continued Troubleshooting The display shows only black screen Ensure that all AC and DC plugs and jacks used by external power supplies are firmly connected Ensure that the SDI connector is firmly plugged in to the SDI source and SDI display Ensure that the Tx and Rx module parts plug correctly to the SDI source and SDI display respectively Check if the SDI source and SDI display are powered on and properly booted Reset the system by de plugging and re plugging the Tx SDI module or Rx SDI module Re boot up the system while connecting the SDIX 100 C Screen is distorted or displays noises Ensure the quality of SDI source and check the extension length of fiber SDIX 100 guarantees the length up to 30KM 3G Maintenance No special maintenance is required for the SDIX 100 and power supplies Ensure that the cables and power modules
3. 1 under UL 758 It is validated by the UL file number SV2038 and project number 04CA05353 1 8 Regulatory Statements UL IEC Statement This equipment has been tested and found to comply with the limits for medical devices in IEC 60601 1 1994 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving device e Increase the separation between the equipment e Connect the equipment into an outlet on a circuit different from that to which the other device s are connected e Consult the manufacturer or field service technician for help e Type of protection against electric shock Class equipment e Degree of protection against electric shock Not classified no applied parts e Classification according to the degree of protection against ingress of water as detailed in the current edition of IEC 529 IPX0 ordinary equipme
4. Setup O Hardware requirements m You have to have a SDI multimedia systems Camera OB Van Broadcasting equipment using SDI signal SDI Monitor etc or it should support the maximum graphic resolution feature of Monitors to be connected m No special requirements of memory size CPU speed and chipsets if you ve already properly installed your SDI systems O Software requirements m No special restrictions if you ve already properly installed your SDI systems O DC Power Adapter Technical Advisory m The SDIX 100 C is designed to use only 5V external power m Pin description 1 2 System Requirements for Setup Installation Important Please follow the installation procedure as below Improper or no operation may result if the start up sequence is not correctly followed Step 1 Carefully unpack the contents of the shipping group Step 2 Connect the plug of the Tx side of SDIX 100 to the receptacle of SDI source Camera Broadcasting equipment etc directly Do NOT recommend to use any intermediate cable or adapter between them It may deteriorate the signal transmission performance a Figure 2 Tx module of SDIX 100 Step 3 As shown in Figure 3 plug the 5V power adaptor in the shipping group to the TX amp Rx Module Connecting 5V power adaptor to SDIX 100 Cable is indispensable procedure for working Figure 3 SDIX 100 with power adapter 1 3 Installation Step 4 Connect the Rx side of SDIX 1
5. are stored or used in a benign environment free from liquid or dirt contamination There are no user serviceable parts Refer all service and repair issues to Opticis Technical Support and Service For commercial or general product support contact your reseller For technical service contact Opticis by email techsupp opticis com or visit its website at www opticis com 1 5 Troubleshooting Maintenance Technical Support Product Specifications SDIX 100 C Fiber Optic 3G SDI Extension module O Transmission of multi rate SDI digital video over one 1 fiber lt converts and transmit one 1 channel of SMPTE 424M 3G SDI SMPTE 292M HD SDI or SMPTE 259M SDI Available both Single mode and Multi mode Supports embedded audio such as embedded AES audio signal Offers clock recovery circuit included model SDIX 100C as an option Extension limit 30km 3G 1080p 3G SDI format Recommended Fiber optic Cable Glass Single mode fiber with 1310 1550nm of bandwidth and ST terminated connector General electrical specification E Data Transfer Rate Graphic Data Max 3Gbps E Link Power Budget Min 11dB E Optical Connector ST Connector mM Electric Connector Type from Modules 75 Ohm BNC Male Mechanical specifications of Tx and Rx module parts m Dimensions 19 5mm 19 5mm 82 7mm W H D Environmental Specifications E Operating temperature 20 C to 70 C m Storage temperature 30 C to 85 C mE Humidi
6. nt e This equipment is not suitable for use in the presence of flammable anesthetics or oxygen e Mode of operation continuous operation Class A of CE and FCC certification The SDIX 100 manufactured by Opticis Co Ltd which are all certified by IEC EN61000 3 4 referred in Accession Number 07 1334 0217 as classified in Class A 1 9 Regulatory Statements 2013 Opticis Co Ltd All Rights Reserved Revision 1 2 3 Sep 2013 Opticis Locations Headquarters Opticis Co Ltd 16Fl Kins Tower 8 Sungnam daero 331 beon gil Bundang gu Seongnam si Gyunggi do 463 844 South Korea Te l 82 31 719 8033 Fax 82 31 719 8032 www opticis com For order support please contact your Distributor or Reseller For technical support check with the Opticis web site www opticis com or contact techsupp opticis com
7. or service other than by Opticis or its authorized agents causes other than from ordinary use or failure to properly use the Product in the application for which said Product is intended Dispose of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative z consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 1 7 Warranty Information FCC CE Statement This device complies with part 15 of FCC Rules and EN 55022 61000 3 for CE certification Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the
8. pTICIS Miniature Fiber Optic 3G SDI Extension Module User s Manual SDIX 100 SDIX 100C Doc No OE SD130903 Rev1 2 Manual Contents Manual Contents Welcome Product Description System Requirements for Setup Installation Troubleshooting Maintenance Technical Support Product Specifications Warranty Information Regulatory Statements Pictorials Figure 1 Fiber Optic 3G SDI Extension module SDIX 100 Figure 2 Tx Module of SDIX 100 Figure 3 SDIX 100 with power adapter Figure 4 Rx Module of SDIX 100 C Figure 5 Whole Connection of SDIX 100 C 1 0 Manual Contents b b h b ee ee oO N OQOGAOUMN O Welcome Congratulations on your purchase of the Miniature Fiber Optic 3G SDI Extension module SDIX 100 SDIX 100C This manual contains information that will assist you in installing and operating the product Product Description Shipping Group O SDIX 100 Tx Rx Module One 1 set of unit length as your request Option SDIX 100 Tx Rx SDIX 100C Tx Rx Including re clocker O DC 5V 1 5A power adapter Two 2 units O PG 100 4 pin XLR male to mini XL female connector cable 12V power supply cable directly from camera Option O User s Manual O Plastic hard case One 1 One 1 3G spi_ Artua Digital Video Digital Video Input Input Figure 1 Fiber Optic 3G SDI Extension module SDIX 100 1 1 Welcome Product Description System Requirements for
9. ty 5 to 95 RH DC Power Adapter O Supply Power DC 5V 1 5A O Cord DC Jack Core is 5V and outer is GND Warranty Information 1 One Year Warranty Opticis warrants this fiber optic 3G SDI extension cable to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the date of purchase from Opticis or its authorized resellers If a product does not work as warranted during the applicable warranty period Opticis shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of Opticis Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to Opticis for repair under warranty or not Warranty Limitation and Exclusion Opticis shall have no further obligation under the foregoing limited warranty if the product has been damaged due to abuse misuse neglect accident unusual physical or electrical stress unauthorized modifications tampering alterations